Metal halide perovskites for X-ray detection and imaging

H Wu, Y Ge, G Niu, J Tang - Matter, 2021 - cell.com
Metal halide perovskites (MHP) have demonstrated excellent X-ray detection performance,
thanks to their compelling properties including large mobility-lifetime product, strong X-ray …

Enhancing the X-ray differential phase contrast image quality with deep learning technique

Y Ge, P Liu, Y Ni, J Chen, J Yang, T Su… - IEEE Transactions …, 2020 - ieeexplore.ieee.org
Objective: The purpose of this work is to investigate the feasibility of using deep convolutional
neural network (CNN) to improve the image quality of a grating-based X-ray differential …

Dynamic X-ray imaging with screen-printed perovskite CMOS array

…, D Liang, XF Yu, H Zheng, X Sun, Y Ge - Nature …, 2024 - nature.com
High performance X-ray detector with ultra-high spatial and temporal resolution are crucial
for biomedical imaging. This study reports a dynamic direct-conversion CMOS X-ray detector …

Sequential growth of 2D/3D double‐layer perovskite films with superior X‐ray detection performance

…, J Wang, J Yang, J Chen, S Xiao, Y Ge… - Advanced …, 2021 - Wiley Online Library
Perovskite materials in different dimensions show great potential in direct X‐ray detection,
but each with limitations stemming from its own intrinsic properties. Particularly, the sensitivity …

Metal halide scintillators with fast and self‐absorption‐free defect‐bound excitonic radioluminescence for dynamic X‐ray imaging

…, G Niu, H Wu, L Yin, X Du, M Niu, Y Ge… - Advanced Functional …, 2021 - Wiley Online Library
Scintillators for radiation detection are of great significance in medical imaging, security,
and nondestructive inspection. The current challenge for scintillators is to simultaneously …

Ultrathin and ultrasensitive direct X‐ray detector based on heterojunction phototransistors

Y Gao, Y Ge, X Wang, J Liu, W Liu, Y Cao… - Advanced …, 2021 - Wiley Online Library
Most contemporary X‐ray detectors adopt device structures with non/low‐gain energy
conversion, such that a fairly thick X‐ray photoconductor or scintillator is required to generate …

An aerosol-liquid-solid process for the general synthesis of halide perovskite thick films for direct-conversion X-ray detectors

W Qian, X Xu, J Wang, Y Xu, J Chen, Y Ge, J Chen… - Matter, 2021 - cell.com
Medical X-ray computed tomography requires imaging at a low dose rate and in a large area.
Halide perovskites have shown high potential for X-ray detection, but a pressing challenge …

ADAPTIVE-NET: deep computed tomography reconstruction network with analytical domain transformation knowledge

Y Ge, T Su, J Zhu, X Deng, Q Zhang… - … imaging in medicine …, 2020 - pmc.ncbi.nlm.nih.gov
Background Recently, the paradigm of computed tomography (CT) reconstruction has shifted
as the deep learning technique evolves. In this study, we proposed a new convolutional …

Artifact removal using a hybrid-domain convolutional neural network for limited-angle computed tomography imaging

Q Zhang, Z Hu, C Jiang, H Zheng, Y Ge… - Physics in Medicine & …, 2020 - iopscience.iop.org
The suppression of streak artifacts in computed tomography with a limited-angle configuration
is challenging. Conventional analytical algorithms, such as filtered backprojection (FBP), …

Artifact correction in low‐dose dental CT imaging using Wasserstein generative adversarial networks

Z Hu, C Jiang, F Sun, Q Zhang, Y Ge, Y Yang… - Medical …, 2019 - Wiley Online Library
Purpose In recent years, health risks concerning high‐dose x‐ray radiation have become a
major concern in dental computed tomography ( CT ) examinations. Therefore, adopting low‐…