0% found this document useful (0 votes)
113 views2 pages

Power Distribution Bay UL

Power Distribution Bay UL

Uploaded by

JoseGarcia
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
113 views2 pages

Power Distribution Bay UL

Power Distribution Bay UL

Uploaded by

JoseGarcia
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

BDCBB/BD

DFB
-48
8 VDC Po
ower Dis
stributio
on Bay
Overrview
The Eltek BDCB
BB/BDFB can
c be equipped as a single
bus bay or offe
er up to six
x load bus
sses depe
ending
upon
n the desire
ed configuration. The
e bay is des
signed
to provide 800
0 amps per feed at 48V,

and has a
maximum total current ca
apacity of 4800 amps.

Minip
pack 1.6kW Systtem with DC disttribution
with lloadbreakers an
nd controller

BD
DCBB
B/BDF
FB
-48 VDC POW
WER DIS
STRIBUTION BAY
Y
Doc 210
02146, Issue 3.1
1

BENEFITS

PR
RODUCT DES
SCRIPTION

K
KEY FEATUR
RES

Confiiguration

Th
he distribution bay is equippe
ed with the
industry-leading Smartpack2 controller,
s
load vo
oltage and
which displays system
urrent on eac
ch bus. In ad
ddition to
cu
sttandard alarm
ms, the Sm
martpack2
co
ontrollers
extensive
e
p
programing
ca
apabilities allo
ow for custo
om alarm
th
hreshold value
es, alarm grou
uping and
more through both remote and local
ccess.
ac

FUNCTION SMAR
RTPACK2
ADVANCED-F
CONTROLLER
R

Th
he bay can be
e ordered eithe
er with or
und bus
without an internal grou
ssembly. Optio
onal external grround bars
as
arre also available. It is designe
ed for toporr bottom-feed cabling.
c

EITHER TWO, FOUR, OR SIX 800 AMP A/B


INPUT FEEDS
S, EACH EQUIPPE
ED WITH 1000
AMP SHUNTS
S

Ea
ach bay inclu
udes a stand ard cable
management package.

ARM WITH USER--CONFIGURABLE


AUDIBLE ALA
ON/OFF FEAT
TURE

The B
BDFB can be co
onfigured with up to six
load busses and uttilizes TPS/TLS
S fuses to
amps and or plu
ug-in breakers up to 250
125 a
amps
s.
Capacity
At 80
00A per feed at
a -48V, it offers a total
current capacity of 4800A.
ABS C
Circuit
Optio
onal Alarm Batttery Supply (AB
BS), which
allow
ws for continue
ed alarm and controller
c
ss in the event of power loss.
acces
Acces
ss and Control
The S
Smartpack2 co
ontroller offers remote
and local access to system
m data,
progrrammable setttings, and alarming and
monittoring features
s.

Eltek
2925 E Plano Pk
kwy, Plano, TX 75
5034, USA

ptional rear-fa
acing DC loa d cabling
Op
av
vailable.

Phone
e: 469-330-9100

AGEMENT PACKA
AGE
CABLE MANA
LARM BATTERY SUPPLY (ABS)
OPTIONAL AL
CIRCUIT
AKER
FUSE AND/OR CIRCUIT BREA
DISTRIBUTION
N:
LE IN THE FIELD
UPGRADEABL
TALL WITH OPTIONAL 2
15 DEEP, 7 T
EXTENSIONS
S
ONS
26 AND 34--WIDE BAY OPTIO

MIL TERMINATIO
ONS PER FEED
TWO 750 KCM
UR 750 KCMIL
OPTIONAL INCREASE TO FOU
TERMINATION
NS PER FEED

REMOVABLE SIDE PANELS


950-1, 2ND
NEBS LEVEL 3; CSA/VDE 609
EDITION
E
Eltek 2014 ww
ww.eltek.com

1(2))

BDCBB/BDFB
TECHNICAL SPECIFICATIONS
ENVIRONMENTAL
Operating Temperature

-5C to 30C

Storage Temperature

-40C to 70C

Safety Compliance

EN/UL 60950-1, 2nd Edition

NEBS Compliance

Level 3

EMC

GR-1089; Environmental GR- 63

Earthquake Rating

Zone 4

GENERAL
Dimensions (D x H x W)

15 x 84 x 26 / 34 (two width options)

Maximum Weight (approx.)

375 lbs. (26 bay) / 415 lbs. (34 bay), fully loaded

CAPACITY
Total Capacity

Six Panels, 144 positions (72 per A/B load)

Distribution

Breakers or fuses

CABLING
Maximum Input Cable Size

Two 750 kcmil per feed (option of four terminations per feed)

Input Lug Specs

Two-hole 3/8 on 1 centers

Output Lug Specs

One-pole breakers: Two-hole 1/4 on 5/8 centers (one-pole breakers)


Two- and three-pole breaker adapters: Two-hole 3/8 on 1 centers

Doc 2102146 Issue 3.1

Specifications are subject to change without notice

SMARTPACK2 CONTROLLER FEATURES

Load History and Statistics


o

Monitoring

Average and peak values of all monitors

SD Card Slot
o
o
o

o
o

Stores event log, data log and energy log


Backup configuration and setup
Upload firmware to control system

Additional Features

Ethernet Port
o
o

10/100BASE-T Ethernet
Auto-MDI/MDIX (detects the type of cable connected
and configures the port accordingly)

o
o
o
o
o

Energy Logging
o

Individual load panels have both voltage and current


monitored
Load alarm monitoring
Load descriptions are configurable

Large, full-color screen


User-friendly touchpad navigation
Status messages clearly displayed
SNMP Traps
Supports Eltek CAN nodes, including alarm, battery,
and load monitors

Both total and individual energy consumption are


logged

Eltek 2925 E Plano Pkwy, Plano, TX 75034, USA

Phone: 469-330-9100

Eltek 2014 www.eltek.com

2(2)

You might also like