STANDARD OPERATING PROCEDURE

Subject: Inspection and Testing of Procured Goods and Equipment’s

1. PURPOSE
 This procedure aims at providing methods of inspection of input materials used for
construction.
2. SCOPE
 This procedure covers building materials, bulk materials, and important
consumables.
3. RESPONSIBILITY
 Stores Manager and Quality Manager is overall responsible for receiving
inspection activity.
4. PROCEDURE
 On arrival of material, details are entered in the register maintained at the gate.
 Materials are immediately checked for its validity, quality, quantity as per quality
plan, either by QAE/Stores.
 The receipt of material is entered in the ledger.
 If material is rejected, the same is endorsed on the back of the DC .A copy of the
DC / Receiving Inspection Report is sent to the Procurement department for
calculating Supplier Quality Rating.
 An inspection report is prepared for the materials, received and inspected.
 All sample sizes are taken as per BIS Codes and checked as per relevant code
requirements
 Materials received from ISO 9000–certified & reputed manufacture/dealer are
accepted based on their past performance/ inspection / test reports.
 Their inspection reports / products are cross checked at the commencement of
the project.
 Sub-contractor premises are audit checked for ensuring their processes at the
start of the project / once in a year.
 Characteristics which cannot be verified by in-house facilities at site are checked
with approved outside laboratories.
 List of approved laboratories is maintained by RE/QAE.
 Items under sub contracted processes such as water proofing / painting are
qualified for its processes, persons and operating parameter.

5. NON-CONFORMING PRODUCT
 Results of inspections are recorded in Receiving Inspection Report and NC
products are sent back to suppliers immediately and supplier advised for
corrective action. A copy of the DC / Receiving Inspection Report is sent to the
Procurement department for calculating Supplier Quality Rating.
6. RECORDS
 Inward Material Inspection Report
 List of approved laboratories
Inward Material Inspection Report

INCOMING MATERIAL INSPECTION REPORT

Name of work Report No:


Contractor : Date:
Consultant :
Client :
Location :
IRN No. : NIL
Delivery Challan No./ Date : WAYBILL /INVOICE NO:
Supplying Vendor / Agency
LR/RR/No.

Heat No./Batch no./cast no./


Sl. No. Description of Material Material Specification Unit T.C No Remarks
Identification No.

Total Quantity
MATERIAL PHYSICALLY VERIFIED FOR GOOD CONDITION, DIMENTIONS AND QUANTITY FOUND IN ORDER