4-20 mA Control/Alarm/Indicator
Model : CT-2012       ISO-9001, CE, IEC1010
  LUTRON ELECTRONIC
                   4-20 mA Controller/Alarm/Indicator
                   Model : CT-2012
FEATURES
* Input : 4-20 mA DC, linear.                                                  Relay Output     Number          2 relays
* User can default the desired display value between                                            Function        Relay 1 :
  -1999 to 9999 ( decimal point can be selected to DP1,                                                         High/Low control relay.
  DP2, DP3 ) and all the preset data will be saved into                                                         Relay 2 :
  the memory circuit permanently.                                                                               High/Low alarm relay.
* According the 4 to 20 mA input signal, user can preset                                        Max load        0.5 ACA/250 ACV
  the desire display value between -1999 to 9999 ( decimal                                                      0.5 DCA/24 DCV
  point can select to DP1, DP2, DP3 ). Until set the display                                                       * Do not apply the relay
  value, all the data will save into the memory circuit                                                              contact load current
  permanently                                                                                                        > 0.5 A, other wise the
* When CT-2012 cooperate LUTRON's 4 to 20 mA                                                                         relay may be damaged
  transmitters ( or any other transmitters if it build 4 to                                                          permanently without
  20 mA output signal ), whole system will become the                                                                warranty.
  high performance Controller/Alarm/Indicator for                                               * Decimal point adjustment :
  following measuring functions : Humidity, Light, pH,                                             DP1, DP2, DP3
  Dissolved Oxygen, Conductivity, Vibration, Pressure,                         Main             * Low limit of range adjustment
  Sound, Temperature, RPM, Hz, Load cell ( Weight,                             Internal            0 mA = X X X X, min. value is -1999
  Force ), Potential ( Angle, Level ). ACV, ACA, DCV,                          Function         * High limit of range adjustment
  DCA, WATT....                                                                Selection           20 mA = X X X X, max. value is 9999
* Easy to adjust the function factors by push button                                            * Alarm function adjustment :
  on the front panel.                                                                              High Alarm or Low alarm.
* Control output : 2 points ( COM, NO ).                                                        * Control function adjustment
* Alarm output : 2 points ( COM, NO ).                                                             High control or Low control.
* Control Relay will make action when the reading value                                         * Deviation of Alarm
  reach to control value.                                                                       * Deviation of Control
* Hysteresis value setting for control and alarm function.                                      * Filter value of display reading
* Large red LED display, high brightness and easy to read.                                      * Offset adjustment.
* Microprocessor circuit ensures high accuracy and                                              * Gain adjustment.
  provides special functions and features.                                                      Default of internal function :
* DC 12V power supply output.                                                                   Without advice previously, the function
* RS232/USB computer interface.                                                                 of CT-2012 will preset :
* Power : 90 ACV - 264 ACV, 50/60 Hz.                                                           * 4 mA = 0, 20 mA = 9999.
* Standard 96 X 48 mm DIN case.                                                                 * High control mode.
* Optional data acquisition software.                                                           * High alarm mode.
                                                                               Front Panel      * Control set-point value adjustment.
GENERAL SPECIFICATIONS                                                         Function         * Measuring value ( Process value )
Display       * 4 digits red LED,                                              Selection           offset. Use to offset the PV indication
                 14 mm ( 0.55 inch ) digit height                                                  from the actual PV.
              * 4 indicators :                                                                  * Alarm set-point value adjustment.
                 PV ( process value ) indicator                                Operating        0 to 50 ℃.
                 SV ( set value ) indicator                                    Temperature
                 Control out indicator                                         Operating        Less than 80% R.H.
                 Alarm out indicator                                           Humidity
              * According the 4-20 mA input signal,                            Power Supply     90 to 260 ACV, 50/60 Hz.
                 user can preset the desire display value                      Power            Approx. 4.7 VA/AC 110V.
                 between -1999 to 9999 ( decimal point                         Consumption      Approx. 5.3 VA/AC 220V.
                 can select to DP1, DP2, DP3 ). Until set                      Weight           384 g/ 0.84 LB.
                 the display value, all the data will save                     Dimension        DIN size : 96 x 48 mm.
                 into the memory circuit permanently                                            Panel cut size : 92 mm x 46 mm.
Input Signal  Linear, 4 to 20 mA                                                                Depth : 110 mm.
Circuit       Custom chip of microprocessor LSI                                Accessories      Instruction manual........................... 1 PC
              circuit.                                                         Included         Case holder with screw.....................2 PCs
Sampling Time Approx. 1 second.                                                Optional         * Data Acquisition software,
External      DC 12 V, 50 mA max.                                              Accessories        SW-U801-WIN.
Power Supply                                                                                    * RS232 cable, UPCB-02.
Data Output   RS 232 PC serial interface.                                                       * USB cable, USB-01.
* Appearance and specifications listed in this brochure are subject to change without notice.                                       0909-CT2012