IT9420                                                                installation instructions
MECHANICAL
1. Assure orientation and measurement range.                                             2. Align mounting feet so that flat surface
   Make sure that angle of inclination does not                                             is in plane of rotation
   exceed measurement range
                    A                                                  B
                           g                                  g
      IT9420-                                                          -1110
                           degrees of
                       clockwise rotation                                               3. Mount transducer via the 2 mounting
                                                   degrees of
                                                counter-clockwise
                                                                                           holes to a flat solid surface.
ELECTRICAL                                          rotation
  RECOMMENDED INSTALLATION
                                                                       SHIELD
                                                                                                                         to power supply (-)
                                                                                +                  -
                                                                                    12 - 40 VDC
                                                                                POWER SUPPLY
                                                                                                                     4 - 20 mA
                                                                                          ground
                                   PIN N0.              SIGNAL
                                      A            12...40 VDC IN
                                      B            4...20 mA OUTPUT
                                                                                                                         4...20 mA output from sensor
                                        A
                                    B       F                                                                             ground
                                   C        E
                                        D
                                   contact view    connector: MS3106E-14S-6S
                                                        max wire size: 16 AWG                                          CONTROLLER
                                                  IMPORTANT! sensor chassis must be earth grounded!
  REDUCING RANGE (to less than factory calibrated full stroke range)
    1. Remove Phillips-head plugs to expose flat head zero and span trimming
       potentiometers.
    2. Rotate inclinometer to desired counter-clockwise position and adjust
       zero pot until output is at 4 mA.
                                                                                                                             "ZERO" (4 mA) Adjust
    3. Rotate inclinometer to desired clockwise position and adjust span pot                                               "SPAN" (20 mA) Adjust
       until output is at 20 mA.
    4. Repeat steps 2 and 3.
    5. Replace plugs.
IT9420 INSTALLATION MANUAL.P65  060697