PWD, WRO
Irrigation Design Handbook
                 8. DESIGN OF VERTICAL TYPE DROP ON PERMEABLE FOUNDATION
HYDRAULIC PARTICULARS
LOCATION                                                          LS       250      M
DISCHARGE REQUIRED                                                         4.09     cumecs
U/S BED LEVEL                                                             298.3     M
D/S BED LEVEL                                                             296.9     M
LENGTH OF DROP                                                                3     M
CONCENTRATION FACTOR                                                          0     %
EXIT GRADIENT OF BED MATERIAL                                               0.2
FLOOR THICKNESS AT END (ASSUMED)                                              1     M
FlOOR THICKNESS FOR U/S APRON                                               0.6     M
THICKNESS OF CUTOFF                                                         0.6     M
DESIGN OF CANAL SECTION
  (UNLINED PORTION)
BED WIDTH                                                                      3 M
SIDE SLOPE               1                                                   0.5
MANNINGS COEFFT N                                                         0.025
BED SLOPE=1 IN 2500                                                      0.0004
DEPTH OF WATER                                                               1.5 M
                          1                                 1.5                               1
                              0.5                                                       0.5
                                                             3
Area "A"                                                                  5.625 Sq m
Wetted Perimeter "P"                                                   6.354102 m
Hydraulic mean Depth "R"=A/P                                           0.885255
Velocity "V"=1/nR^2/3*S^0.5
          =1/ 0.0X0.9^2/3X0.0^0.5
                                                    0.737568                        m/s
Discharge       "Q"=A X V                           4.148821                        Cumecs
                                                    >                                   4.09 CUMECS
Depth of water                                            1.5                       m
D/S waterlevel=D/Sbed level+depth of water=296.9 +1.5
D/S waterlevel                                          298.4                       m
Depth of u/s water                                        1.5                       m
U/s water level      =              298.3 +               1.5
U/s water level                                         299.8                       m
Approach velocity 'v'=Q/A                 = 0.41/0.56
Approach velocity                                    0.727111                       m/s
Velocity head =v /2g
                 2
                                          = 0.7271^2 /2*9.81
Velocity head                                       0.026947                        m
U/S TEL =U/S water level+velocity head= 299.80+0.02695
U/S TEL                                               299.827                       m
Top width of drop (Assumed)                               0.8                       m
Q = 1.835 LH3/2(H/B)1/6 as per page 317 of Design of irrigation structures by Varshney
                    0.41=1.835X 3XH^3/2X(H/0.8)^1/6
(III) Typical Design of Various Irrigation Structures - 8.Vertical drop ( Design)                     Page No.
PWD, WRO
Irrigation Design Handbook
Head causing flow required for the design discharge                   0.81825 m
                                            say                          0.82 m
(III) Typical Design of Various Irrigation Structures - 8.Vertical drop ( Design)   Page No.
PWD, WRO
Irrigation Design Handbook
Crest level = U/s TEL-H              299.827 -               0.82
Crest level                                                299.00 m
d= Height of the crest in metre above d/s bed =            299.00 -            296.9
d= Height of the crest in metre above d/s bed                2.10
Width of crest = 0.55*d^0.5 as per page317 of Design of irrigation structures
                       =0.55*0.21^0.5                                      by R.S.Varshney
Width of crest                                          0.797026 m
                                              say             0.8 m*
Provide a top width of                                        0.8 m
DESIGNING OF STILLING BASIN
Assuming depth of water cushion               =               0.3 m
Basin level                                   =296.90-0.3
Basin level                                                 296.6 m
           h= u/s water level-basinlevel      =299.8-296.6
                       h =                                    3.2 m
           v= (2gh)^.5           =(2*9.81*3.2)^0.5
Velocity of flow at the toe=                            7.923636 m/sec
           d1 =Q/(L/v)           =0.41/3*0.79
Depth of flow at the toe d1=                            0.172059 m
           h=          =3.2 -0.2
                                 h=                     3.027941 m
           v = (2gh)^0.5         =2*9.81*0.30^0.5
                                 v=                     7.707672 m/s
           d1 =Q/(L/v)           =0.41/3*0.77
                                 d1                      0.17688 m
Hence initial depth d1                                       0.18 m
Froude's No.        "F =v/(gd)^0.5            =0.77/(9.81x0.18)^0.5
Froude's No.        "F"                                 5.800327
Sequent depth     "d2" =d1/2(-1+(1+8F2)^0.5)
                    =0.18/2(-1+(1+8*0.58^2)^0.5)
Sequent depth     "d2"                                       1.389262 m
Basin floor level       RWL - Sequent Depth                  =298.4-0.14
                                                             297.0107 m
Depth of cistern          =            1/4(H.HL)^2/3 as per page 634 Irrigation and hydraulic
                                                        structures by S.K. Garg
             HL =         U/S FSL - D/S FSL
                          =               299.8 -                        298.4
                          HL                                                1.4 m
                          H                                                0.82 m
Depth of cistern          DC           =1/4*(0.83*1.4)^2/3
                          DC                                         0.273706 m
Provide a basin depth of                                                  0.3 m
 Basin floor level=                                         296.9 -                 0.3 =       296.6
(III) Typical Design of Various Irrigation Structures - 8.Vertical drop ( Design)                       Page No.
PWD, WRO
Irrigation Design Handbook
Basin floor level based on hydraulic criteria =     297.0107 *
Provide basin floor level as                             296.6 m
Length of basin     5x(H*HL)^0.5 As per page 629 of Irrigation engineering and
                                    hydraulic structures by S.K. Garg
                                    =5X(0.83*1.4)^0.5
                                                            5.351534 m
                                                     Say          5.40 m
Provide a basin length of                                          5.5 m
DESIGN OF PERMEABLE FOUNDATION
Bottom width of drop body wall (from drop wall stabilit            2.6 m
Scour depth and depth of cutoff
Scour depth = 0.475(Q/f)^1/3
taking silt factor "f" =1.0
Scour depth = "R" =0.475*(0.41/1)^1/3
Scour depth "R"                                             0.759629 m
U/S Scour level= U/S MFL -1.25 R                            298.8505 m
U/s Floor level (taken = basin level unless specified            296.6 m
If u/s floor level is different type in cell F119                296.6 m
Depth of cutoff required from scour considerations =U/S floor level-scour level
                                                  =296.60-0.2989
Depth of cutoff required from scour considerations           -2.25046 m
Minimum depth of cutoff =(u/s water depth/3)+0.6                   1.1 m
Provide a u/s cutoff depth of                                      1.1 m
However provide a depth of                                         1.5 m
Depth of u/s cutoff                                                1.5 m
Bottom of u/s cutoff=               =296.60-1.5                  295.1 m
D/s Scour level          D/S FSL - 1.5R                     297.2606 m
Depth of Cutoff required from scour considerations           -0.36056 m
Minimum depth of cutoff =(D/s water depth/2)+0.6                  1.35 m
Provide a d/s cutoff depth of                                      1.4 m
However provide a depth of                                           2m
Depth of d/s cutoff                                                  2m
Bottom of d/s cutoff                =296.9-2.0                   294.9 m
Floor Length Required From Exit Gradient Considerations
Exit gradient                                                      0.2
Taking head upto bed level only
 H = U/S Bed level - D/S Bed level                =298.3-296.9
 H = U/S Bed level - D/S Bed level                                 1.4 m
  d = Depth of d/scutoff                                             2m
                         Ge =                   H     1
                                                d PÖl
                                l       =               1.240863
                               l        =            (1+(1+a2)^0.5)/2
                               a        = Ö (2 l-1)2 -1             1.09 m
(III) Typical Design of Various Irrigation Structures - 8.Vertical drop ( Design)   Page No.
PWD, WRO
Irrigation Design Handbook
Length of floor required from exit gradient                   2.19 m
Length of floor required from hydraulic criteria =length of basin+width of bodywall+
                                                                   2*cut-off thick
Length of floor required from hydraulic criteria =       5.50+2.600+2*0.60
Length of floor required from hydraulic criteria               9.3 m
                     Maximum say                               9.5 m
Length of floor provided                                       9.5 m
Calculation of pressures
u/s pile
             = b/d        '=           6.333
              1/a         =            0.158      Say         0.16
From table in pg 91 of CBIP pub. no. 12
   For        1/a         =             0.16
              fD          =           23.953
              fE          =           34.779
   fE1        =100 -      0                    =              100 %
   fD1        =100 - 23.953                     =        76.04737 %
   fc1        =100 - 34.779                     =        65.22105 %
Correction for floor thickness
Assumed floor thickness for U/S                   =             0.6 m
CorrectionCf =( ( fD1-fC1)/d)*thickness
          CorrectionCf                            =        4.330526 +ve
Correction for mutual interference of pile
          Ci            =     19x ÖD/b1x         (d+D)/b
Where                  b1 = centre to centre distance of piles
                       b = total floor length provided
          d             = depth of pile          =1.5-0.6       0.9
          D             = depthof pile below the floor          1.1
                            of the first pile whose inter-
                            ference has to be determined
                                                 Ci =      1.406246
          corrected       fc1      =0.652+0.43+0.14
                       corrected         fc1           =   70.95783 %
D/S Pile
            = b/d       '=            4.75
             1/a        =     0.21052632                    Say            0.21
From table in pg 91 of CBIP pub. no. 12
   For       1/a        =             0.21
              fD        =         27.1263
              fE        =           39.747
                                            fE2         =            39.74737 %
                                            fD2         =            27.12632 %
(III) Typical Design of Various Irrigation Structures - 8.Vertical drop ( Design)      Page No.
PWD, WRO
Irrigation Design Handbook
                                            fc2          =                     0%
(III) Typical Design of Various Irrigation Structures - 8.Vertical drop ( Design)   Page No.
PWD, WRO
Irrigation Design Handbook
Correction for floor thickness
Assumed floor thickness for D/S                          =                  1m
          CorrectionCf                                   =           6.310526
Correction for mutual interference of pile
          Ci           =    19x ÖD/b1x                  (d+D)/b
Where
          d            = depth of pile                               1.110738
             D             =  depthof pile below the floor 0.910738
                              of the first pile whose inter-
                              ference has to be determined
                                                   Ci =      1.293302
                          corrected       f E2           =   32.14354 %
                 s.no.          f            pile1        pile2
                   1           fE             100         32.14
                   2           fD            76.05        27.13
                   3           fC            70.96        0.00
                                                                    Elevation of HGL
 U/S WL       D/S WL           Head                      U/S Pile                          D/S Pile
                                                 fE1       fD1          fC1         fE2      fD2        fC2
                                                     100 76.04737        70.96       32.14    27.13       0.00
Static head
  299.00          296.9             2.1             2.1 1.596995 1.490114 0.675014 0.569653                  0
                                                    299 298.497 298.3901 297.575 297.4697                296.9
Dynamic head
   299.8   298.4                    1.4              1.4 1.064663 0.99341 0.45001 0.379768                   0
                                                   299.8 299.4647 299.3934 298.85 298.7798               298.4
                          HGL             Line
299.3934
                                                                                                        298.85
298.3901
                                                                                                       297.575
                                                                                                      296.9
                                                             8.9
(III) Typical Design of Various Irrigation Structures - 8.Vertical drop ( Design)                                Page No.
PWD, WRO
Irrigation Design Handbook
FLOOR            THICKNESS
Assuming that there is water in the basin upto d/S bed level, immedieately after the flow ceases,
the head is calculated from d/s bed level.                                                        5.5
   (a)    Unbalanced head at          1.3              m from                                     0.6
           centre of d/s pile                                        0.794074
          Thickness required=H/(G-1)                                 0.567196
Provide a thickness                                                       0.6 m
   (b)    Unbalanced head at          3.3              m from
           centre of d/s pile                                        0.977242
          Thickness required                                          0.69803
Provide a thickness of                                                    0.7 m
   (c)    Unbalanced head at          5.8              m from
           centre of d/s pile ie at toe                              1.206203
          Thickness required                                         0.861574
Provide a thickness of                                                    0.9 m
Dynamic condition
Check for thickness of drop at toe
Assuming the jump forms at toe itself for worst condition
Elevaton of HGL at toe ie                5.8 m from 299.2041
          Centre of D/s pile
          Unbalanced head at                      5.8 m from         2.304135
           centre of d/s pile ie at toe
Taking 2/3 rd the head ,      Head =                                  1.53609
          Thickness required                                         1.097207
Provide a thickness of                                                    1.1 m
UPSTREAM            PROTECTION            WORKS
As per pg 304 of Theory and Design of Irrigation structures       by R.S Varshney
Pitching for a length equal to u/s water depth shall be provided with a slope of 1:10
U/S water depth             1.5 m
Provide stone protection for length =                           3m
DOWNSTREAM               PROTECTION            WORKS
As per pg 305 of Theory and Design of Irrigation structures                         by R.S Varshney
Pitching for a minimum length
equal to 3 times d/s water depth shall be provided
D/S water depth             1.5 m
Length of pitching required                                                 4.5
Provide stone pitching for a length of                            5m
(III) Typical Design of Various Irrigation Structures - 8.Vertical drop ( Design)                       Page No.
  PWD, WRO
  Irrigation Design Handbook
STABILITY ANALYSIS OF DROP WALL:
T.B.L                                                       300.3       m
F.T.L                                                      299.00       m
Maximum flood discharge                                      4.09       cumecs
U/S. bed level                                              298.3       m
D/S bed level                                               296.9       m
Depth of water =                                              1.5       m
U/S waterlevel=                                             299.8       m
D/S waterlevel=                                             298.4       m
Top level of wingwall=                                     299.00       m
Foundation level=                                           296.6       m
Height of wing wall=                                          2.4       m
Width of platform=     B=                                     0.8       m
Rear slope=               1:                                 0.75
Rear batter                                                   1.8       m
Front slope=              1:                                    0
Front batter=                                                   0       m
b3=          Base width=                                      2.6       m
Height=                                                       2.4       m
Density=                                                            2 t/m3
f=                                                                 22   o
d=             f/2=                                                11   o
a o=                                                                0
ah=            B*I*ao                                               0
av=            1/2*ah=                                              0
l=             tan a(h)/(1±a(v)=
                   -1
                                                                    00               or          0
a=                                                       36.8699        o
i=                                                                  0
Increment=                                                          0%
Unit weight of masonry=                                            2.3 t/m3
Unit weight of water=                 1 t/m3
 STRESS DUE TO EARTH PRESSURE ACTIVE EARTH PRESSURE:
cosl                                            1
Cos^2(f-l-a)=                             0.9341
Cos^2a=                                      0.64
Cos(d+l+a)=                               0.6708
Sin(f+d)=                                 0.5446
Sin(f-i-l)=                               0.3746
Cos(a-i)=                                     0.8
Cos(d+l+a)=                               0.6708
           1+ Sin(f+d)*Sin(f-i-l)                        0.5
                                                               =            1.6166
              Cos(a-i)*Cos(d+a+l)
                       1                             2
           1+ Sin(f+d)*Sin(f-i-l) 0.5            =       0.38265
  (III) Typical Design of Various Irrigation Structures - 8.Vertical Drop (Stability analysis of Drop wall)   Page No.
  PWD, WRO
  Irrigation Design Handbook
               Cos(a-i)*Cos(d+a+l)
                 Cos^2( f-d-a)                  =         2.17586
      cosl*    Cos^2a* f-a-l)
(1+aV)=                                                         1
Ca=            (1+aV)* cos^2 ( f-d-a)                                   1              2
                   cosl*  Cos^2( Cos(d+a)                      1+ Sin(f+d)*Sin(f-i) ^0.5
                                                                  Cos(a-i)*Cos(d+a)
                   Ca        =               0.83259
Ps=1/2*w*h *Ca=
              2
Earth pressure:                                           4.79572 t
Vertical component=                                       3.55662 t
Horizontal component=                                     3.21705 t
                                               0.8         299.00
                   0.75
               1                       2.4
                                         a      b
                                                          O         296.6
                                               0.8
                                 1.8
                                                    2.6
Condition1: No Flow Condition
Sl.no                                                                             FORCES
             Coefficient L                      B         H         Unit wt. Verticl HorizontaL.A                 MOMENT
I .Weight of masonry                                                                                              +VE      -VE
a.                   0.5     1                      1.8       2.4        2.3     4.968                        1.4   6.9552
b.                     1     1                      0.8       2.4        2.3     4.416                        0.4   1.7664
III . Static earth pressure:
Vertical component:                                                            3.55662                          2 7.113235
Horizontal component:                                                                  3.21705                0.8          2.573637
                                                                  V=           12.9406 3.21705                    15.83483 2.573637
X=                                                        1.02477 m
e= b/2-x=                                                 0.27523                                                 13.2612
6e/b=                                                     0.63514
Maximum stress=                              P/A*(1+6e/b)=            8.1383 t/m2
Minimum stress=                              P/A*(1-6e/b)=             1.816 t/m2
  (III) Typical Design of Various Irrigation Structures - 8.Vertical Drop (Stability analysis of Drop wall)                 Page No.
  PWD, WRO
  Irrigation Design Handbook
Condition2:             Maximum Flow Condition
U/S waterlevel=                          299.8                       m
Top level of wingwall=                  299.00                       m
Foundation level=                        296.6                       m
Height of wing wall=                        2.4                      m
Width of platform=                          0.8                      m
Front slope=           b1=      :         0.75
Front batter                  1             1.8                      m
Rear slope=                     :             0
Rear batter=                  1               0                      m
b3=          Base width=                    2.6                      m
Height=                                     2.4                      m
Density=                                                        1 t/m3
f=                                                             22    o
d=             f/4=                                            5.5   o
a o=                                                            0
ah=            B*I*ao                                           0
av=            1/2*ah=                                          0
l=             tan a(h)/(1±a(v)=
                   -1
                                                                00           or                  0
a=                                                         36.8699   o
i=                                                              0
Increment=                                                      0%
Unit weight of masonry=                                        2.3 t/m3
Unit weight of water=                 1 t/m3
 STRESS DUE TO EARTH PRESSURE ACTIVE EARTH PRESSURE:
cosl                                            1
Cos^2(f-l-a)=                             0.9341
Cos^2a=                                      0.64
Cos(d+l+a)=                               0.7388
Sin(f+d)=                                 0.4617
Sin(f-i-l)=                               0.3746
Cos(a-i)=                                     0.8
Cos(d+l+a)=                               0.7388
           1+ Sin(f+d)*Sin(f-i-l 0.5=                      1.54098
              Cos(a-i)*Cos(d+a+l)
                       1                               2
           1+ Sin(f+d)*Sin(f-i-l) 0.5              =       0.42112
              Cos(a-i)*Cos(d+a+l)
                 Cos^2( f-d-a)                 =           1.97561
       cosl*   Cos^2a* f-a-l)
                             (1+aV)=                            1
  (III) Typical Design of Various Irrigation Structures - 8.Vertical Drop (Stability analysis of Drop wall)   Page No.
  PWD, WRO
  Irrigation Design Handbook
Ca=            (1+aV)*                f-a)                             1              2
                   cosl*       Cos^2( Cos(d+a)                1+ Sin(f+d)*Sin(f-i) ^0.5
                             Cos^2a*                             Cos(a-i)*Cos(d+a)
                   Ca        =        0.83197
Pa=1/2*w*h *Ca=
              2
Earth pressure:                                       2.39608 t
Vertical component=                                   1.61475 t
Horizontal component=                                 1.77025 t
                                              0.8                    299.00
                   0.75                                        0
               1                                                    1
                             2.4
                                         a     b          c
                                                                    o           296.6
                                              0.8         0
                                   1.8
                                     2.6
Condition1: At maximum Flow Condition
Sl.no                                                                             FORCES
              Coefficient L        B     H                          Unit wt. Verticl HorizontaL.A                   MOMENT
I .Weight of masonry                                                                                                +VE       -VE
a.                    0.5    1       1.8                      2.4       2.3     4.968                         1.4     6.9552
b.                      1    1       0.8                      2.4       2.3     4.416                         0.4     1.7664
c.                    0.5    1         0                      2.4       2.3         0                                       0
iv Weight of water                                                                  0                                       0
a                     0.5    1       1.8                      2.4         1      2.16                           2        4.32
b                       1    1       2.6                      0.8         1      2.08                         1.3       2.704
ii Earth pressure                                                                                                           0        0
Vertical component:                                                           1.61475                           2   3.229503
Horizontal component:                                                                    1.77025              0.8             1.416196
iii Water pressure
a                       1    1       0.8                      2.4         1                  1.92             1.2               2.304
b                     0.5    1       2.4                      2.4         1                  2.88             0.8               2.304
D/S Water pressure
                      0.5    1       1.5                      1.5         1                 1.125             0.5     0.5625
                                                                              15.2388 7.69525                        19.5376 6.024196
  (III) Typical Design of Various Irrigation Structures - 8.Vertical Drop (Stability analysis of Drop wall)                    Page No.
  PWD, WRO
  Irrigation Design Handbook
Xbar=                                                    0.88678
e= b/2-x=                                                0.41322
6e/b=                                                    0.95359
Maximum stress=                           P/A*(1+6e/b)=                11.45 t/m2
Minimum stress=                           P/A*(1-6e/b)=                0.272 t/m2
DESIGN OF ABUTMENT AND UPSTREAM WING WALL
U/S waterlevel=                  299.8 m
Top level ofabutment=            300.3 m
Foundation level=                296.6 m
Height of wing wall=               3.7 m
Width of platform=     b1=        0.45 m
Front slope=               1:        0
Front batter                         0m
Rear slope=                1:      0.7
Rear batter=                      2.59 m
b3=          Base width=          3.04 m
Height=                            3.7 m
Density=                                                       2 t/m3
f=                                                           22    o
d=             f/2=                                           11   o
a o=                                                        0.02
ah=            B*I*ao                                          0
av=            1/2*ah=                                         0
l=             tan a(h)/(1±a(v)=
                   -1
                                                               00            or                  0
a=                                                        34.992   o
i=                                                             0
Increment=                                                     0%
Unit weight of masonry=                                      2.3 t/m3
Unit weight of water=                 1 t/m3
 STRESS DUE TO EARTH PRESSURE ACTIVE EARTH PRESSURE:
cosl                                           1
Cos^2(f-l-a)=                             0.9495
Cos^2a=                                   0.6711
Cos(d+l+a)=                               0.6948
Sin(f+d)=                                 0.5446
Sin(f-i-l)=                               0.3746
Cos(a-i)=                                 0.8192
Cos(d+l+a)=                               0.6948
           1+ Sin(f+d)*Sin(f-i-l 0.5=                    1.59872
              Cos(a-i)*Cos(d+a+l)
                       1                             2
           1+ Sin(f+d)*Sin(f-i-l) 0.5            =       0.39125
  (III) Typical Design of Various Irrigation Structures - 8.Vertical Drop (Stability analysis of Drop wall)   Page No.
PWD, WRO
Irrigation Design Handbook
             Cos(a-i)*Cos(d+a+l)
(III) Typical Design of Various Irrigation Structures - 8.Vertical Drop (Stability analysis of Drop wall)   Page No.
  PWD, WRO
  Irrigation Design Handbook
                 Cos^2( f-d-a)                 =      2.03624
    cosl*      Cos^2a* f-a-l)
(1+aV)=                                                          1
Ca=            (1+aV)*                f-a)                              1              2
                   cosl*       Cos^2( Cos(d+a)                 1+ Sin(f+d)*Sin(f-i) ^0.5
                             Cos^2a*                              Cos(a-i)*Cos(d+a)
                   Ca        =        0.79668
Pa=1/2*w*h *Ca=
              2
Earth pressure:                                       10.9066 t
Vertical component=                                   7.84448 t
Horizontal component=                                 7.57744 t
                                             0.45         300.3
                    0                                          0.7
               1                                                     1
                                      3.7
                                               a           b
                     296.6                                           o
                                        0    0.45         2.59
                                  0
                                               3.04
Sl.no                                                                              FORCES
             Coefficient          L            B      H              Unit wt. Verticl HorizontaL.A            MOMENT
I .Weight of masonry                                                                                          +VE      -VE
a.                     1                1      0.45            3.7       2.3 3.8295                     2.815 10.78004
b.                   0.5                1      2.59            3.7       2.3 11.0205                1.726667 19.02864
ii Earth pressure
Vertical component:                                                          7.84448             0.863333 6.772399
Horizontal component:                                                                    7.57744 1.233333 9.345503
                                                                             22.6944 7.57744                  45.92659
                                                      2.02369
e= b/2-x=                                             0.50369
6e/b=                                                 0.99413
Maximum stress=                             P/A*(1+6e/b)=             14.887 t/m2
Minimum stress=                             P/A*(1-6e/b)=             0.0438 t/m2
  (III) Typical Design of Various Irrigation Structures - 8.Vertical Drop (Stability analysis of Drop wall)              Page No.
  PWD, WRO
  Irrigation Design Handbook
DESIGN OF DOWNSTREAM WING WALL
D/S waterlevel=                                              298.4   m
Top level ofabutment=                                        298.9   m
Foundation level=                                            296.6   m
Height of wing wall=                                           2.3   m
Width of platform=     b1=                                    0.45   m
Front slope=               1:                                    0
Front batter                                                     0   m
Rear slope=                1:                                  0.7
Rear batter=                                                  1.61   m
b3=          Base width=                                      2.06   m
Height=                                                        2.3   m
Density=                                                        2 t/m3
f=                                                             22    o
d=             f/2=                                             11   o
a o=                                                            0
ah=            B*I*ao                                           0
av=            1/2*ah=                                          0
l=             tan a(h)/(1±a(v)=
                   -1
                                                                00           or                  0
a=                                                          34.992   o
i=                                                              0
Increment=                                                      0%
Unit weight of masonry=                                        2.3 t/m3
Unit weight of water=                 1 t/m3
 STRESS DUE TO EARTH PRESSURE ACTIVE EARTH PRESSURE:
cosl                                           1
Cos^2(f-l-a)=                             0.9495
Cos^2a=                                   0.6711
Cos(d+l+a)=                               0.6948
Sin(f+d)=                                 0.5446
Sin(f-i-l)=                               0.3746
Cos(a-i)=                                 0.8192
Cos(d+l+a)=                               0.6948
           1+ Sin(f+d)*Sin(f-i-l 0.5=                      1.59872
              Cos(a-i)*Cos(d+a+l)
                       1                               2
           1+ Sin(f+d)*Sin(f-i-l) 0.5              =       0.39125
              Cos(a-i)*Cos(d+a+l)
                 Cos^2( f-d-a)                 =           2.03624
    cosl*      Cos^2a* f-a-l)
(1+aV)=                                                         1
  (III) Typical Design of Various Irrigation Structures - 8.Vertical Drop (Stability analysis of Drop wall)   Page No.
  PWD, WRO
  Irrigation Design Handbook
Ca=            (1+aV)*                f-a)                              1              2
                   cosl*       Cos^2( Cos(d+a)                 1+ Sin(f+d)*Sin(f-i) ^0.5
                             Cos^2a*                              Cos(a-i)*Cos(d+a)
                   Ca        =        0.79668
Pa=1/2*w*h2*Ca=
Earth pressure:                                       4.21445 t
Vertical component=                                   3.03121 t
Horizontal component=                                 2.92802 t
                                             0.45         298.9
                    0                                          0.7
               1                                                     1
                                      2.3
                                               a           b
                     296.6                                           o
                                             0.45         1.61
                                  0
                                               2.06
Sl.no                                                                              FORCES
             Coefficient          L            B      H              Unit wt. Verticl HorizontaL.A            MOMENT
I .Weight of masonry                                                                                          +VE      -VE
a.                     1                1      0.45            2.3       2.3 2.3805                     1.835 4.368217
b.                   0.5                1      1.61            2.3       2.3 4.25845                1.073333 4.570736
ii Earth pressure
Vertical component:                                                          3.03121             0.536667 1.62675
Horizontal component:                                                                    2.92802 0.766667 2.244817
                                                                             9.67016 2.92802                  12.81052
                                                      1.32475
e= b/2-x=                                             0.29475
6e/b=                                                 0.85849
Maximum stress=                             P/A*(1+6e/b)=             8.7242 t/m2
Minimum stress=                             P/A*(1-6e/b)=             0.6643 t/m2
  (III) Typical Design of Various Irrigation Structures - 8.Vertical Drop (Stability analysis of Drop wall)              Page No.