Data sheet 3VT5716-3AA30-0AA0

CIRCUIT BREAKER 3VT5 HIGH BREAKING


CAPACITY ICU=55KA, 415V AC 3-POLE; CIRCUIT
BREAKER W/O OVERCURRENT RELEASE WITHOUT
AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM
SWITCH

Model
product brand name SENTRON
Product designation 3VT1_5 molded case circuit breakers
Design of the operating mechanism toggle handle
Type of the driving mechanism / motor drive No

General technical data


Number of poles 3
Size of the circuit-breaker 3VT5
Electrical endurance (switching cycles) / typical 4 000
Usage category A
Performance class for circuit breaker H
Mechanical service life (switching cycles) / typical 10 000
Operating frequency / maximum 1/h 120

Voltage
Insulation voltage / rated value V 690
Surge voltage resistance / rated value kV 8

Protection class
Protection class IP IP40

3VT5716-3AA30-0AA0 Changes preserved


Page 1/5 22.03.2016 © Copyright Siemens AG
Dissipation
Power loss [W]
● for rated value of the current / at AC / in hot W 40
operating state / per pole
● maximum W 120

Electricity
Continuous current / rated value A 1 600
Derating temperature / for the rated value of the °C 50
continuous current

Main circuit
Operating frequency
● 1 / rated value Hz 50
● 2 / rated value Hz 60
Operating voltage
● rated value / maximum V 690
● for main current circuit / at AC / at 50 Hz / V 690
maximum
● for main current circuit / at AC / at 60 Hz / V 690
maximum
● for main current circuit / at DC / maximum V 440
Operating current
● at 40 °C / rated value A 1 600
● at 50 °C / rated value A 1 600
● at 55 °C / rated value A 1 460
● at 60 °C / rated value A 1 460
● at 65 °C / rated value A 1 320
● at 70 °C / rated value A 1 320

Auxiliary circuit
Number of CO contacts / for auxiliary contacts 0
Number of NC contacts / for auxiliary contacts 0
Number of NO contacts / for auxiliary contacts 0

Suitability
Suitability for use Contact unit without release
● Disconnecting means Yes

Product details
Product component
● Trip indicator No
● Auxiliary switch No
● Voltage trigger No
● undervoltage release No

3VT5716-3AA30-0AA0 Changes preserved


Page 2/5 22.03.2016 © Copyright Siemens AG
● undervoltage release with leading contact No
Product extension / optional / motor drive Yes

Product function
Product function
● Ground fault protection No
● for neutral conductors / Short-circuit and No
overload proof
● Phase failure detection No
● Overload protection No

Short circuit
Operational short-circuit current breaking capacity
(Ics)
● at 240 V / rated value kA 45
● at 415 V / rated value kA 36
● at 500 V / rated value kA 30
● at 690 V / rated value kA 20
Maximum short-circuit current breaking capacity (Icu)
● at 240 V / rated value kA 85
● at 415 V / rated value kA 55
● at 500 V / rated value kA 45
● at 690 V / rated value kA 20
Short-circuit current making capacity (Icm)
● at 415 V / rated value kA 140

Connections
Arrangement of electrical connectors / for main front side
current circuit
Type of electrical connection / for main current circuit busbar connection

Mechanical Design
Height mm 494
Width mm 210
Depth mm 157
Mounting position with vertical mounting surface +/-180° rotatable, with
vertical mounting surface +/- 30° tiltable to the front
and back
Mounting type fixed mounting
Net weight kg 22.96

Environmental conditions
Ambient temperature
● during operation / minimum °C -40
● during operation / maximum °C 70
● during storage / minimum °C -40

3VT5716-3AA30-0AA0 Changes preserved


Page 3/5 22.03.2016 © Copyright Siemens AG
● during storage / maximum °C 70

Certificates
Equipment marking
● acc. to DIN EN 61346-2 Q
● acc. to DIN EN 81346-2 Q

General Product Approval Declaration of Test other


Conformity Certificates
Typprüfbescheinigu Umweltbestätigung sonstig
ng/Werkszeugnis

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
http://www.siemens.com/lowvoltage/catalogs
Industry Mall (Online ordering system)
https://eb.automation.siemens.com/mall/en/WW/Catalog/Product/3VT57163AA300AA0
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
http://support.automation.siemens.com/WW/view/en/3VT57163AA300AA0/all
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3VT57163AA300AA0
CAx-Online-Generator
http://www.siemens.com/cax
Tender specifications
http://ausschreibungstexte.siemens.com/tiplv

134,5
x; 210

\fArial|b0|i0|c0|p34;494

0|c0|p34;15

s 3VT4,5 48
;R1
\fArial|b0|i0|c0|p34;240

4;7�

34
314

0|p
0|c
\H34.999x;350

|i
b0
;21�
\H0.028571x;

|p34|c0|p3

l|
ria
\fA
\fArial|b0|i
i0|c0|b0|i0
300

\fArial
\fArial|b0|

9
x
;4
p34
\fArial|b0|i0|c0|p34;18

|c 0|
i0
0|
200

l|b
ria
\fA

\fArial|b0|i0|c0|p34;50 \fArial|b0|i0|c0|p34;70 70

3VT5716-3AA30-0AA0 Changes preserved


Page 4/5 22.03.2016 © Copyright Siemens AG
last modified: 22.03.2016

3VT5716-3AA30-0AA0 Changes preserved


Page 5/5 22.03.2016 © Copyright Siemens AG