0% found this document useful (0 votes)
124 views3 pages

Emergency Stop Relays, Safety Gate Monitors: Pnoz X7 24 V Dc/Ac, Pnoz X7 Ac

The document describes two emergency stop relay models, the PNOZ X7 24 V DC/AC and the PNOZ X7 AC. It provides technical specifications for both models including electrical data, times, mechanical data, internal wiring diagrams, external wiring examples, and general technical data. The relays are used for emergency stop and safety gate monitoring applications meeting Category 2 of EN 954-1.

Uploaded by

RKB
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
124 views3 pages

Emergency Stop Relays, Safety Gate Monitors: Pnoz X7 24 V Dc/Ac, Pnoz X7 Ac

The document describes two emergency stop relay models, the PNOZ X7 24 V DC/AC and the PNOZ X7 AC. It provides technical specifications for both models including electrical data, times, mechanical data, internal wiring diagrams, external wiring examples, and general technical data. The relays are used for emergency stop and safety gate monitoring applications meeting Category 2 of EN 954-1.

Uploaded by

RKB
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Emergency Stop Relays, Safety Gate Monitors

Category 2, EN 954-1
PNOZ X7 24 V DC/AC, PNOZ X7 AC

Technical Data PNOZ X7 24 V DC/AC PNOZ X7 AC

Electrical Data
Supply Voltage 24 V DC/AC 42, 48, 110, 115,
120, 230, 240 V AC
Tolerance 85 ... 110 % 85 ... 110 %
Power Consumption Approx. 2 W/2 VA Approx. 3 VA
Voltage and Current at reset circuit/
feedback control loop 24 V DC, 50 mA 24 VDC, 50 mA
Switching Capability
in accordance with EN 60947-4-1, 10/91 AC1:
240 V/6 A/1500 VA 240 V/3 A/700 VA
DC1:
24 V/6 A/150 W 24 V/3 A/70 W
in accordance with EN 60947-5-1, 10/91 AC15:
230 V/5 A 230 V/3 A
Emergency Stop Relay in DC13:
accordance with VDE 0113 part 1, 24 V/6 A 24 V/3 A
11/98, EN 60204-1, 12/97 and IEC Output Contacts 2 (N/O) safety contacts
204-1, 11/98 Contact Fusing to EN 60947-5-1, 10/91 6 A quick or 4 A slow
Times
Response Delay Aver. 50 ms Aver. 250 ms
Features Max. 400 ms Max. 700 ms
Release Delay Max. 85 ms Max. 120 ms
● Single-channel operation Recovery Time Max. 400 ms Max. 400 ms
Max. Supply Interrupt before Approx. 10 ms Approx. 10 ms
De-energisation
Approvals
Mechanical Data
Max. cross section of 2 x 2.5 mm2 single-core or
PNOZ X7 external conductors multi-core with crimp connectors
Dimensions (H x W x D) 87 x 22.5 x 122 mm
● Weight 190 g 240 g

● Description

● 22.5 mm S-95 housing, DIN-Rail


● Mounting
● Relay outputs, positive guided:
– 2 (N/O) safety contacts
● Connections:
– e-stop button
– reset button
● LED indicators for status and
supply voltage
● Increase in the number of
contacts available by connecting
external contactors/relays

Operating Modes

● Single-channel operation
● Automatic reset
● Manual reset

Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Germany NSG-D-2-046-10/02


Telephone +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de
Emergency Stop Relays, Safety Gate Monitors
Category 2, EN 954-1
PNOZ X7 24 V DC/AC, PNOZ X7 AC

Internal Wiring Diagram

– PNOZ X7 24 V DC/AC

Y1 Y2 13 23

K1
A1

+
Switch-on logic, Channel 1
Cycle test,
Control logic Channel 2

K2
A2

14 24

– PNOZ X7 AC

A1 A2 Y1 Y2 13 23

K1

Switch-on logic, Channel 1


~ Cycle test,
G Control logic Channel 2
=

K2

14 24

External Wiring ● Increase in contacts


If required the number of output
● Example 1 contacts on the PNOZ X7 can be
Single-channel E-Stop wiring with increased using external relays /
manual reset contactors.

UB
(L+) Y1 1L1

S1 K3 K4
S3
Y1 Y2 13

A1 Y2

14
– Key
K3 K4
S1: E-Stop button
1L2
S3: Reset button

Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Germany NSG-D-2-046-10/02


Telephone +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de
Emergency Stop Relays, Safety Gate Monitors
Category 2, EN 954-1
PNOZ X7 24 V DC/AC, PNOZ X7 AC

General Technical Data

Unless stated otherwise in the technical details for the specific unit

Electrical Data
Frequency Range AC 50 ... 60 Hz
Residual Ripple DC 160 %
Contact Material AgSnO2
Continuous Duty 100 %
Environmental Data
EMC EN 50081-1, 01/92, EN 50082-2, 03/95
Vibration in accordance with Frequency: 10 ... 55 Hz,
EN 60068-2-6, 04/95 Amplitude: 0.35 mm
Climatic Suitability DIN IEC 60068-2-3, 12/86
Airgap Creepage DIN VDE 0110 part 1, 04/97
Ambient Temperature -10 ... +55 °C
Storage Temperature -40 ... +85 °C
Mechanical Data
Torque Setting on Connection Terminals 0.6 Nm (screws)
Mounting Position Any
Housing Material Thermoplast Noryl SE 100
Protection Mounting: IP 54
Housing: IP 40
Terminal Range: IP 20

The units were tested in accordance with the relevant standards current at
the time of development.

Order References

Type UB Order No.


PNOZ X7 24 V ACDC 774 059
PNOZ X7 42 V AC 774 058
PNOZ X7 48 V AC 774 049
PNOZ X7 110 V AC 774 053
PNOZ X7 115 V AC 774 054
PNOZ X7 120 V AC 774 055
PNOZ X7 230 V AC 774 056
PNOZ X7 240 V AC 774 057

Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Germany NSG-D-2-046-10/02


Telephone +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de