Metal One Corp.
Page                      41 - Z
                                                          GEOCONN -TS                                          Date                 26-Feb-18
                                                    Connection Data Sheet
                                                                                                                Rev.                         N-1
                                         Geometry                                               Imperial                                  S.I.
                                         Pipe Body
                                         Grade                                           13CR L80                            13CR L80
                                         Pipe OD ( D )                                      7                     in          177.80                  mm
       GEOCONN-TS                        Weight                                            26.00                 lb/ft         38.69                 kg/m
                                         Wall Thickness ( t )                              0.362                  in           9.19                   mm
                                t        Pipe ID ( d )                                     6.276                  in          159.41                  mm
                                         Drift Dia.                                        6.151                  in          156.24                  mm
                                         Connection
                                         Coupling OD ( W )                                 7.875                in       200.03                      mm
                                         Coupling Length ( NL )                            10.000               in       254.00                      mm
                                         Make up Loss                                      4.500                in       114.30                      mm
                                         Pipe Critical Area                                 7.55               in2        4,868                      mm2
                                                                                                                  2
                                         Box Critical Area                                 10.32               in         6,656                      mm2
                                         Thread Taper                                                     1 / 16 ( 3/4" per ft )
                                         Number of Threads                                                         5 TPI
                                        Performance
                                         Performance Properties for Pipe Body
                                         S.M.Y.S.                    604      kips                                               2,685               kN
     NL                                  M.I.Y.P.                   7,240     psi                                                49.93               MPa
                                         Collapse Strength          5,410     psi                                                37.31               MPa
                                             Note         S.M.Y.S.= Specified Minimum YIELD Strength of Pipe body
                                                          M.I.Y.P. = Minimum Internal Yield Pressure of Pipe body
                               d
                                         Performance Properties for Connection
                                         Min. Connection Joint Strength      100% of                                          S.M.Y.S.
                                         Min. Compression Yield              100% of                                          S.M.Y.S.
                               W         Internal Pressure                   100% of                                          M.I.Y.P.
                                         External Pressure                   100% of                                          Collapse Strength
                                         Max. DLS ( deg. /100ft)                 52
                                         Recommended Torque
                                                 Min.                                       16,500               ft-lb          22,300               N-m
                                                 Opti.                                      18,300               ft-lb          24,800               N-m
                               D                 Max.                                       20,100               ft-lb          27,200               N-m
                                            Operational Max.                                21,200               ft-lb          28,700               N-m
                                                   Note : Operational Max. torque can be applied for high torque application
                                          Connection Yield Torque                           24,900               ft-lb          33,700               N-m
Legal Notice
The use of this information is at the reader/user’s risk and no warranty is implied or expressed by Metal One Corporation or its parents, subsidiaries or
affiliates (herein collectively referred to as “Metal One”) with respect to the use of information contained herein. The information provided on this Connection
Data Sheet is for informational purposes only, and was prepared by reference to engineering information that is specific to the subject products, without
regard to safety-related factors, all of which are the sole responsibility of the operators and users of the subject connectors. Metal One assumes no
responsibility for any errors with respect to this information.
Statements regarding the suitability of products for certain types of applications are based on Metal One’s knowledge of typical requirements that are often
placed on Metal One products in standard well configurations. Such statements are not binding statements about the suitability of products for a particular
application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use
in a particular application
The products described in this Connection Data Sheet are not recommended for use in deep water offshore applications. For more information, please refer
to http://www.mtlo.co.jp/mo-con/_images/top/WebsiteTerms_Active_20333287_1.pdf the contents of which are incorporated by reference into this
Connection Data Sheet.