LOAD (TE) METER IS NOT RESPONDING
1. CHECK FOR PCS KNOCKED OUT
Recover PCS as per the message displayed in EM2000
2. CHECK FOR GOVERNOR AMPHENOL PLUG TIGHTNESS
Tighten the Amphenol plug.
3. CHECK FOR ENGINE RUN SWITCH POSITION
Switch on the engine run switch (it should be up)
4. CHECK FOR THROTTLE POSITION IN EM2000 DIPLAY
If the throttle position in display is not in actual throttle position, change the
control stand and work further
5. CHECK FOR COUPLERS 543A,B,C TIGHTNESS
Tightness of the couplers in short hood control stand
6. CHECK FOR DIO CARD FAILURE
If there is no indication in EM2000 display, swap DIO cards 1&3, 2&3.
If the problem rectified work further.
7. CHECK FOR LOCKED AXLE MESSAGE
Ensure free movement of that particular axle physically.
If the wheel is rotating freely disable the speed sensor through EM2000 and
work further
8. CHECK FOR NO COMPANION ALTERNATOR OUTPUT MESSAGE
Check the message “NO COMPANION ALTERNATOR OUTPUT-NO
AUXILIARY GENERATOR OUTPUT ”
Check AG drive shaft is intact
If shaft is broken, inform to power control of concern shed.
9. CHECK FOR AG FIELD/FEEDBACK BREAKER TRIPPING
If tripped then RESET and work further
10. CHECK FOR AG FIELD CIRCUIT BREAKER TRIPPING IN ECC2
If Auxiliary Generator circuit in ECC2 tripped, RESET and work further.
11. CHECK FOR POSITION OF ISOLATION SWITCH
Keep isolation switch in RUN position
12. CHECK FOR POSITION OF GF BREAKER
Put in on position (UP)
13. CHECK FOR CREW MESSAGE
Act according to crew message
14. CHECK FOR REVERSER INPUT IN DATA METER
Check for reverser input in power data in data meter
This will be shown “PROP” in “”OP MODE