MAGLIFE Serenity
MAGNETOM Avanto, photo courtesy of Siemens AG
PERFECTION IN MRI MONITORING -
SAFE, USER-FRIENDLY, MOBILE
The MAGLIFE Serenity provides the guarantee for highest safety:
For years, SCHILLER has been one of the world‘s leading suppliers of
MRI compatible patient monitoring systems. The new MAGLIFE Se-
renity guarantees highest ECG quality during magnetic resonance
imaging (MRI) scanning – even under strongest gradient influence.
It monitors all vital parameters during anaesthesia in an MRI envi-
ronment.
MAGLIFE Serenity
A state-of-the-art monitoring sys-
tem for MRI examinations
There are two features that don‘t seem to go together:
ECG monitoring and MRI examination! However,
SCHILLER now provides ECG recording which is based
on the MR technology. This procedure reduces the risk of
burns as well as signal interference to a minimum and per-
mits a standardised operation just like in a conventional
environment.
During MRI examinations, the body temperature can in-
crease or decrease by several degrees. Therefore, ne-
onates, infants as well as patients suffering from reduced
thermoregulation, severe vascular disorders, cardiac ar-
rhythmia, poor general condition or epilepsy require spe-
cial monitoring during the examination.
Specifically developed for the use during anaesthesia of
adults, children and neonates in an MRI environment.
ECG recording all manufacturers. It has been devel- of the MRI examination is only neces-
The patented ECG preparation guar- oped for everyday use, but also to sary if required by the patient‘s condi-
antees a very high protection against meet the highest requirements in an- tion.
gradient artefacts, which makes the aesthesia, cardiology and hemody-
MAGLIFE Serenity the ideal device for namics in an MRI environment. Mobility
cardiovascular application. The facility to move the MAGLIFE Se-
Optical measurement of core and renity easily and quickly to the patient
Gating skin temperature or the MRI is a significant advantage.
Up to three outputs for vital param- The optical measuring method per- Moreover, operation via mains or bat-
eters are available. Both analogue mits an unrestricted and safe position- tery gives additional mobility and flex-
and digital outputs ensure compat- ing of the temperature sensor, even in ibility. The MAGLIFE Serenity provides
ibility with all types of MRI devices. high-field MRIs. a patient orientated data manage-
ment and documentation in every
Wide operational range MAGSCREEN Serenity situation. Since the MAGLIFE Seren-
The MAGLIFE Serenity is compatible The display unit gives the total control ity can be connected to the MAG-
with 0.2 Tesla to 3.0 Tesla imagers of over the main device. An interruption SCREEN, the system can be used with
MRI MONITORING SYSTEM
The advantages of the MAGLIFE
Serenity at a glance:
• Highest ECG quality even under strongest gradient
influence (MRI)
• Several gating outputs for optimal MRI triggering
• Core and skin temperature measurement by use
of an optical sensor
• State-of-the-art gas analysis during anaesthesia
• Network compatibility (wireless LAN, fibre cable, LAN)
• Safe penetration of the Faraday cage
• Accessories suitable for MRI
• Flexibility in the configuration of options
Safety for all patients
The MAGLIFE Serenity provides the safe solution for high-risk
patients who have to undergo MRI examination. The system
is designed for adults, children as well as neonates.
several MRIs in a confined space. and neonates is guaranteed at all easy and quick transport ensures
times. ideal flexibility. The MAGLIFE Serenity
Wireless data transmission can be placed on the MR compat-
The MAGLIFE Serenity is based on the Monitoring the magnetic field ible anaesthesia cart. The simultane-
latest WLAN technology; therefore, The MAGLIFE Serenity has a built-in ous monitoring of 32 vital parameters
the MAGLIFE Serenity and the display stray field analyser which constantly gives you the overview at all times.
unit can communicate via optical fi- analyses the magnetic field, alarm-
bre cable, ethernet or WLAN. ing when the set threshold is reached
and activating the safety shutdown
Customer care and service when exceeded.
We provide 24 hour technical sup-
port. User-friendly features
Clearly visible colour screens on the
Safe SpO2 measurement TFT monitor as well as on the display
Thanks to the optical sensors, a safe unit and easy to use software guar-
SpO2 measurement for adults, infants antee a user-friendly operation. The
U FA C
AN TU
M
R
ED
N
ED A
MAGLIFE Serenity
IN EUR
GN
SI
O
E
P
D E
Technical Data MAGLIFE Serenity
MAGLIFE Serenity:
Dimensions: 440 x 450 x 310 mm / 17.3 x 17.7 x 12.2 in (L x H x W)
Weight: 23 kg
Power supply: 100 / 110 / 240V 55 VA, class I
Battery: 12V 4Ah lasting 90 minutes, or 12V 17Ah lasting 6hrs
Display: Colour VGA 12,1” TFT, 800 x 600 dots
Alarms: Visual and audible for each parameter, 9 tables configurable, Quick Set / All Alarms Off/ Standard
Display unit: Identical to the main screen, full control of all parameters
Network: Optical, WLAN, Ethernet, Various combinations of main screen and display unit,
HIS, PCAS communication (in preparation)
Patient type: All parameters for neonates, children and adults
ECG: 3 channels, Optical amplifier, Backup battery (non-magnetic), @SCS patent for gradient suppression,
Excellent ECG quality, Accurate QRS detection under difficult conditions, Defibrillation protection,
Bandwidth 0,5 - 22 Hz / 0,5 - 40 Hz for rhythmology/trigger, HR 30-250 bpm, Sensitivity 0,25 / 0,5 / 1 / 2 cm/mV,
Speed 25 / 50 mm/s
SpO2/ pulse: Fibre optic sensors, Photo-spectrometry measurement, Measuring range 0 - 99%,
Precision 2% (70 - 99%), Pulse 30 - 250 bpm, Precision 5 bpm
Capnometry:
Sidestream via infrared photo-spectrometry, Galvanic O2 cell (high-speed), Automatic gas detection (2 out of 5
gases), Inspiratory and expiratory data for CO2 / NO2 / O2 / anaesthetic agents, Display % / mmHg / kPa
CO2: Measuring range 0 - 270 mmHg (0 - 12,6 kPa), Frequency 2 - 100 /min, Precision +/- 0,5% / +/- 1 /min
N2O: Measuring range 0 - 950 mmHg, Precision +/- 3%
Anaesthetic agents: Isoflurane, halothane, enflurane, sevoflurane, desflurane, Measuring range 0 - 30%,
Resolution 0,01%, Precision:
- Isoflurane: +/- 0,2% abs. max. - Sevoflurane: +/- 0,4% abs. max.
- Halothane: +/- 0,2% abs. max. - Desflurane: +/- 1% abs. max.
- Enflurane: +/- 0,2% abs. max.
O2: Galvanic cell, Measuring range 0 - 100%, Resolution 1%
NIBD: Oscillometric measurement, Measuring range: Adults 10 - 290 mmHg / Neonates 5 - 145 mmHg,
Precision 3 mmHg
IBP: Disposable and re-usable sensors (non-magnetic), Adjustable for standard disposable sensors,
Measuring range 0 - 300 mmHg, Precision 4 mmHg, Resolution 1 mmHg, Adjustment range 30 / 60 / 150 / 300 mmHg,
Bandwidth 0 - 10 Hz
Temperature: Optical measuring method, Core and skin temperature measurement, Precision 0,2 °C without
calibration, T1 / T2 and Delta T, Robust sensors
Trigger: Optical trigger outputs, 3x analogue, 3x digital
Recorder: 2 channels, thermal paper, Z-folded, 25 mm/s, Manual or automatic start, Trend printout
Trends: 24 hours for all parameters, Highest resolution without data loss, Patient isolation
MAGSCREEN Serenity:
Dimensions: 450 x 398 x 260 mm / 17.7 x 15.6 x 10.2 in (L x H x W)
Weight: 12 kg
10/09
Power Supply: 100 - 240 VAC, 50/60 Hz 60VA, class I
Display: Colour VGA 12,1” TFT, 800 x 600 dots
*2.500565*
Technical data are subject to change without prior notice.
Data sheet for Part no.: 2.500565
Headquarters: SCHILLER AG, Altgasse 68, CH-6341 Baar, Switzerland, Phone +41 41 766 42 42, Fax +41 41 761 08 80, sales@schiller.ch, www.schiller.ch