                      The e-mobility CSS solution with integrated energy             Equipment description
                      storage provides electrification to power cabinets,            The CSS typically houses medium voltage switchgear
E-mobility CSS with
integrated energy     while simultaneously providing a buffer of power in            (up to 40.5 kV), transformers (oil or dry type), a low
storage
                      parallel to the grid. This solution’s typical application is   voltage switchboard with protection devices, ie circuit
                                                                                     breakers or fused disconnects, and integrated energy
                      the peak power demand control. The ease of
                                                                                     storage. The CSS is compartmentalized to isolate the
                      installation of a pre-wired solution drastically reduces
                                                                                     sections to reduce risk of accidental handling.
                      site activities in terms of man-hours, excavation and
                      civil works activities. Different internal layouts are
                      available.                                                     Technical data
                                                                                     Key specifications
                      Features of solution                                           Medium voltage level     from 2.4 – 40.5 kV
                      •   Available in multiple enclosure materials:
                                                                                     Typical ratings (kVA)    up to 1250 kVA
                          -    Steel for rural areas
                          -    Glass reinforced polyester (GRP) for harsh and        Secondary voltage        400-480 V
                               challenging environmental conditions                  Storage power            300 kW
                      •   Internal arc tested design assures high safety             Storage capacity         300 kWh
                          standards for service personnel and public                 Trafo type               Oil or dry
                      •   Lockable enclosure to prevent unauthorized entry
                                                                                     Protection degree        IP 54/23D (MV SWGR,
                      •   Compact design to reduce footprint installation
                                                                                                              LV and storage /trafo)
                      •   Fire tested according to ISO 834
                                                                                     Applicable standards     IEC, GB, AS, GOST,
                      •   Flammability according to UL 94
                                                                                                              ANSI, CSA, and more
                      •   Toxicity according to EN 45545
                       Optional equipment                                                            Installation
                       -   Seismic certifications                                                    -   One-piece delivery factory assembled and tested
                       -   IP35 or IP45 protection for challenging conditions                        -   MV connection and power cabinet connection
                       -   Cooling area chosen to fit different conditions                               needed at site
                       -   SCADA ready                                                               -   Reduced site works
                       -   Remote monitoring                                                         -   Compact design for reduced footprint
                       -   Remote monitoring and control                                             -   No heavy crane needed
                       -   Energy management systems
                       Single line diagram
                                               E-mobility CSS solution with integrated energy storage
—
ABB Ltd.                          —
                                                                                                                                                           1VPD110001A0460 REV A MAY 2019
                                  We reserve the right to make technical           We reserve all rights in this document and in
                                  changes or modify the contents of this doc-      the subject matter and illustrations
                                  ument without prior notice. With regard to       contained therein. Any reproduction,
                                  purchase orders, the agreed particulars shall    disclosure to third parties or utilization of its
                                  prevail. ABB AG does not accept any              contents in whole or in parts is forbidden
                                  responsibility whatsoever for potential          without prior written consent of ABB AG.
                                  errors or possible lack of information in this   Copyright© 2018 ABB
                                  document.                                        All rights reserved
  www.abb.com/mediumvoltage/