0% found this document useful (0 votes)
1K views1 page

Arc Welding Machine Checklist: Name of Project Site

This document is an arc welding machine checklist used to inspect welding equipment and jobsites. It contains sections to check the welding sets, cables and joints, and electrode holders. The checklist ensures the equipment is in good working condition and properly installed to prevent electrical hazards and shocks. Signatures are required from an electrical engineer or authorized electrician, and an HSE manager or officer to verify the inspections.

Uploaded by

Rísês Ãfröz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views1 page

Arc Welding Machine Checklist: Name of Project Site

This document is an arc welding machine checklist used to inspect welding equipment and jobsites. It contains sections to check the welding sets, cables and joints, and electrode holders. The checklist ensures the equipment is in good working condition and properly installed to prevent electrical hazards and shocks. Signatures are required from an electrical engineer or authorized electrician, and an HSE manager or officer to verify the inspections.

Uploaded by

Rísês Ãfröz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 1

Arc Welding Machine Checklist

Name of Project Site: Contractor Name:


Location : Name of Qualified Operator:
Description of Work : Date:

Day Mon Tue Wed Thur Fri Sat Sun


No. ITEMS
Date
A WELDING SETS
1 Connections are properly and effectively insulated.
2 Shock preventor built-in / installed.
3 ON / OFF switch in good working condition.
4 Good earthing and grounding.
B CABLE AND JOINTS
1 Cable and joints are properly and in good condition.
2 Well insulated and no exposed parts.
Size of cable used are proportional to voltage
3
supply.
4 Any overloading whereby cables become hot.
5 Any contact with oil / sharp edges or water.
Are cables properly placed to prevent tripping
6
hazards.
C ELECTRODE HOLDERS
Electrode holders used are in good working
1
condition.
2 Properly insulated and no exposed metal parts.
Holders are kept dried and properly hung up after
3
use.
4 Not in contact with metal parts.
5 Electrodes are detached after welding.
Signature:

Remarks: ( P) good / YES, ( X ) No good / NO. If No, Please indicate in the comments column.

Date: Comments

______________________ ______________________
(Electrical Engineer/ Authorized Electrician) (HSE Manager/ Officer)