OPERATING INSTRUCTIONS                                            SAFETY SUMMARY                                                   connections are correct.                                 1) Snubber Part No.: APRC - 01.
All safety related codification, symbols and instructions   3.Use lugged terminals to meet M3 screws and ensure that 2) MOV Part No.: AP-MOV - 03.
         800XU                                                     that appear in this operating instruction manual must be         the screws are tightened .                               Note: Use snubber as shown above to increase the life
                                                                   strictly observed to ensure operator as well as equipment                                                                                        of internal relay.
                                                                   safety. The instruction manual is meant for personnel                                                                                      DIP SWITCH SETTINGS FOR SELECTION OF
                                                                   involved in wiring, installation, operation and routine
                                                                                                                                    TERMINAL CONNECTIONS
                                                                                                                                                                                                              DELAY MODES
                                                                                                                                                              A1 ( + )            15              25
                                                                   maintenance of the equipment.                                                                                                              SWITCH SETTINGS
                                                                        If the equipment related above safety measures are not
                                                                                                                                                              A2 ( - )         16 18       26 28                            1    2 SCALE                3    4    TIME RANGE
                                                                   practiced, the manufacturer does not have any liability for
                                                                   human or equipment safety.                                                                            SUPPLY: A1 (+), A2 (-)
                                                                                                                                                                                                                                   1                              SEC
                                                                                                                                                    A1 25
                                                                     ! CAUTION: Read complete instructions prior to                                 15 26                AC: 50 / 60Hz
                                                                        installation and operation of the unit.                                                                                                                       3                           MIN
SPECIFICATIONS                                                       ! CAUTION: Risk of electric shock.
                                                                                                                                                                         CONTACT                                                      10                          HRS
SUPPLY VOLTAGE                                                     MAINTENANCE                                                                      16        28
                                                                                                                                                                         5A,250V AC/
                                                                                                                                                                         24V DC, RESISTIVE
      20 to 240 VAC (AC@50 or 60Hz),12 to 240VDC                   1. The power supply should be switched off before                                18        A2                                                                      30                          HRS
                                                                                                                                                                    ON DELAY                   INTERVAL
INPUT                                                                 removing the equipment for cleaning. Ensure that no                          POWER
      Control contact.                                             parts are charged.                                                              RELAY
                                                                                                                                                                          t                       t
OUTPUT CONTACT                                                     2. Clean the equipment with a clean, soft cloth. Do not use                                  t = Set time
      2 C/O (DPDT)                                                    any organic cleaning agent .
RELAY RATING                                                                                                                                   TERMINAL                        DESCRIPTION
                                                                                                                                                                                                                             DIR           5     MODE
      5A @ 230 VAC/24 VDC, resistive.                              INSTALLATION GUIDELINES                                                             A1                L ( + ) T I M E R S U P P LY
DELAY MODES                                                            CAUTION:                                                                        A2                N ( - ) T I M E R S U P P LY                                            ON DELAY
      On delay / Interval modes                                                                                                                        15                COM
TIME RANGES                                                        1. The equipment is built-in type with Class II construction                                                            RELAY                                                 INTERVAL
                                                                                                                                                       16                NC
                                                                   and is protected by reinforced insulation. Terminals are a                                                              CONTACT 1
      1 / 3 / 10 / 30                                                                                                                                  18                NO
      Sec. / min / hr                                              part of the front panel and are protected by means of finger                        25                COM               RELAY
ACCURACY                                                           guard. Finger guards are not to be removed during wiring,                           26                NC                CONTACT 2
      Setting: ± 5% of full scale.                                                                                                                     28
      Repeat: ±0.5% or 50 msec whichever is greater.               installation, operation or maintenance.                                                               NO
POWER CONSUMPTION                                                  2. Conductors must not come in contact with the internal         TYPICAL LOAD CONNECTIONS
      2 VA max.                                                    circuitry of the equipment as it may lead to a safety hazard.
LED INDICATION                                                                                                                      1. For load current less than 0.5A                                      MODES OF OPERATION
                                                                   3. Circuit breaker or main switch should be installed
      Power ON.                                                                                                                            230VAC
                                                                   between power source and supply terminals to facilitate                 L   N                                                              Fig1. On Delay:
      Relay ON.
RESET : On interruption of power.                                  power ON/OFF function. This installation must be in a                                                                                       Supply
RESET TIME                                                         convenient position normally accessible to the operator.                                                     A1 25
                                                                                                                                                                                 (L)    (COM2)                 Voltage
      Less than 100 msec.                                              CAUTION:                                                                                                  15 26
                                                                                                                                                                                (COM1) (NC2)
SIZE (IN MM)                                                       1.! The equipment should not be installed in the
      22.5 (W) x 75 (H) x 101 (D).                                                                                                                Snubber
                                                                                                                                                                                                               N/O Contact
HOUSING                                                            environmental conditions other than those mentioned in this                                 L
                                                                                                                                                               O
                                                                                                                                                                                                               NC Contact
      Flame retardant engineering plastic.                         manual.                                                                         C
                                                                                                                                                               A                                                                            t
MOUNTING                                                           2. Fuse Protection: The equipment does not have a built-in                      R
                                                                                                                                                               D
                                                                                                                                                                                16 28
                                                                                                                                                               1
      DIN rail mounting.                                           fuse. A fuse of rating 275 VAC/1Amp is recommended.                                                          (NC1)   (NO2)                                     t = set time delay
      Screw mounting.                                                                                                                                                           18 A2
                                                                   EMC Installation Guidelines:                                                                                 (NO1)    (N)                   Fig 2. Interval Delay:
TEMPERATURE
                     o
      Operating: 0 C to 50 C.
                             o                                     1. Use proper input power cables with shortest connections                                                                                  Supply
                   o       o
      Storage: 0 C to 50 C.                                        and twisted type.                                                                                                                           Voltage
HUMIDITY                                                           2. Layout of connecting cables shall be away from any            2. For bigger loads, use interposing relay/contactor
      Up to 95% RH.                                                internal emf source.
WEIGHT                                                                                                                                    230VAC
                                                                   Mechanical Installation Guidelines:                                     L   N                                                               N/O Contact
      115 grams.                                                                                                                                                                                               NC Contact
                                                                   1. The equipment uses a clamp for T type DIN rail only.
                                                                                                                                                                                                                                            t
                                                                   2. Ensure that the rail clamp is correctly fitted.                                                                     A1 25
                                                                                                                                                                                           (L)    (COM2)
PANEL DIMENSIONS                                                   3. Slide the equipment using appropriate tools and holding                                                              15 26
                                                                                                                                                                                          (COM1) (NC2)
                                                                                                                                                                                                                                          t = set time delay
                                                                   the unit from the front side, slide it over the fixed rail.
                                             m
                                                 11.5mm
                                            m
22.5mm
                                        80
                             101mm                                                                                                                            LOAD 1
                                       4.
                                                                   WIRING GUIDELINES                                                                                                                         (Specifications subject to change as development is a
                                                                                                                                                         A2
                                                                                                                                                         CONTACTOR
                                                                                                                                                                          NO                                 continuous process)
                                                                       CAUTION:                                                                                          COM
                                                                                                                                                                          A1                                 Selec Controls Pvt. Ltd.
 R
                                                                   1.! The power should be turned off while wiring and                                                                                       (Formerly Selectron Process Controls Pvt. Ltd.)
                                                          61.0mm
             8 9
                                                                                                                                                                                          16 28
                   10
         7         10
     6                  75           35 75
                                                                                                                                                                                          (NC1)   (NO2)
                                     mm mm
     5
     4
         3         0
                        mm
                                                                   maintenance to prevent the risk of electric shock. Do not                           C    R                                                Tel:91-22-28476443, Fax:91-22-28471733,
                                                                                                                                                                                           18 A2
                   0
             2 1
 ON
                                                                   touch the terminals when power is ON.
                                                                                                                                                        Snubber                           (NO1)       (N)    Website: www.selec.com
                                                                                                                                                                                                             E- mail: sales@selec.com
                                                                   2. Wiring shall be done strictly according to the terminal
                                                                                                                                                                                                            Document name: Operating/0711/800XU/ Version 1   OP218-V01   Page 1 of 1
                              85mm           Mounting holes        layout with shortest connections. Confirm that all the