DEVELOPMENT CONTROL REGULATIONS (DCR)
         Maximum height of building = 15m or G+3 or stilt+4 floors
         Maximum floor space index(FSI) = 1.5
         Maximum plot coverage = 60%
         Front set back= Min-3m up to 18m-3m
                          18m to 24m-4.5m more than 24m & NH&SH-7m
   Site setback = 3m or ¼ height which ever is higher
   Rear set back = 3m or ¼ height which ever is higher
   Minimum width of corridor = 2.0m
   Internal vehicular access way including passage if any with in the site will
    be a clear width of 7.2 metre and such vehicular accesss will be available
    for every building block in the site within a distance of 50 metres further it
    shall be a clear open to sky and no projection of structure over it is
    permissible
   Vehicular ramp in set back spaces around buiding blocks may be permitted
    subject to the condition that the clearance of the proposed ramp from the
    property boundary/street alignment shall be min 1.5m & a clear
    motorable driveway of min 3.5min with is available around building block
   The structure incidental to main activities such as water closet/pump room,
    transformer room, transformer yard, electric room shall not be
    constructed as individual block for the purpose of these rules however
    these structures may be permitted in the prescribed setback space that
    they do not fall in the driveway and its height does not exceed 4 metres
    provided further that transformer and electrical rooms floor area not
    exceed 15 sqm & water closet & pump room block not exceed 6 sqm
   A wachman or caretaker booth or kiosk not exceeding 2.5mx2.5m in size at
    each gate and not exceeding 3m in height or power/transformer room not
    exceeding 4m in height shall be permitted in the setback space at ground
    level after leaving 7m clear setback from the main structure provided that
    the height restrictions shall not apply for an open transformer
   Gate pillars with or without arches with a min headroom clearance of
    5.50m atleast to a width of 3.5m may be permitted after leaving 7m clear
    setback from the main structure
   Layout and subdivision- laying out of land for building purpose
 Splay- A splay at the intersection of two or more streets
 Width of road = road width up to 10m, splay to be left 1.5mx1.5m
                   Road width above 10m,splay to be left 3.0mx3.0m
 BUILDING LINE
 RECREATION SPACE
 NO OF PARKING SPACE
 The dimension of parking stall shall be 5.0mx2.5m with a min which width
  of driveway of 3.5m for one way movement and 7.2m for two way
  movement
 Minimum inside radius of lane 4.5m, preffered gradient 4% (1 in 25),
  absolute maximum gradient 5% (1 in 20)
 The angled parking where a stall is adjacent to large element such as wall,
  min stall width shall be 2.7m for parallel parking, where cars cannot be
  parked by reversing, min stall length shall be 7.2m
 Adequate blending of ramp grades at floor level shall be provided this can
  be achieved by provision of straight slope 3.0m to 3.6m long at half the
  grade of ramp
 Structure permissible in the minimum prescribed front, side, rear setback
  Incase of non-multistorey buildings(including ordinary buildings)
  unsupported sunshades,wardrobes, balconies and other projections from
   the main walls,such structures do not fall within prescribed setback space
 The above (iii)&(vi) shall be permitted in the setback spaces provided a
  minimum clearance of 0.5m for an ordinary building &1.5m for a special
  building/group development & for any non-multistorey building from the
  property boundary or street alignement whichever closer
 If a non-continous projecting structure stated above in the setback
  exceed 50% of side/length of building they shall be taken as forming part
  of main building and shall not be allowed in prescribed setbacks
 Motor room of area not exceeding 2 sqm each & height not exceeding
  1.8m without affecting parking & driveway requirements
 A compound wall of height not exceeding 2m
 2 numbers one entry/one exit Additional gate for every 50m frontage may
  be allowed in large cities if frontage exceeds 50M
 RAIN WATER CONSERVATION
 There shall be a pebble bed of 1m width &1.5m depth all around building
  and filled with rounded pebbles of 5cm to 7.5cm size the concrete
  pavement around building has to be slopped at about 1 in 20 towards the
  pebble that rain water from the terrace and side open spaces flow over
  this pavement and spread into a pebble bed around. dwarf walls in
  masonry of 7.5cm hieght shall be constructedat the entrance and exit
  gates to retard rainwater collected into the compound from draining out
  to the road
 In the ground floor level water closets shall be 0.9m above the road level
  to ensure free flow
 ELECTRICAL ROOM
 Electrical room shall not be less than 3m the electrical room with rcc roof
  shall have clear floor area 6mx4m with a vertical clearance of 2.75m
 Three sides of the room shall be covered with brick wall and the fourth
  side towards approach road shall be covered with M.S rolling grill shutter
  of width not less than 3m with locking facility the electrical room shall
  have raised cement flooring with cable duct of 450mm width &750mm
  depth all around inside the room and close to exterior wall shutters
 Open space within the permises for installation a clear space of 10mx4m
  or 5mx5m open to sky having an approach road of width not less than
  3m upto the public road shall be provided within the consumer premises,
  preferably at main entrance
   NATIONAL BUILDING CODE (NBC)
  The open spaces around the building shall not be less than 6m
  Minimum clear width for staircase 2.00m
REQUIREMENTS:
   Administration block
   Auditorium
     Academic block-labs, art-classroom, studio, lecturer rooms
     Common conference
     Resource centre(library)
     IT lab
     Open amphitheatre(OAT)
     Gallery
     Canteen
     Student facility centre
     Staff residences
     Hostels(boys & girls)
     Guest houses
     Sports and recreation areas
NIFT INFRASRUCTURE ART LABS AND STUDIO
     Machine room and material workshop
     Leather lab
     Jewellery lab
     Painting lab
     Welding workshop
     Design and creative thinking studio
     Surface design lab
     Weaving lab
     Textile testing lab
     Cad lab
     Pattern making lab
     Garment construction lab
     Design studio
     Art lab
     Hand flat lab
     Shima seiki lab
     Sports and lingerie machine lab
     Specialized SPME sewen and product machinery equipment
     Hanger system material handling lab
     Visual merchandise display labs
AUDITORIUM
   Two basic types of seating arrangements
   Multiple aisle & continental aisle
   In a multiple arrangement If an aisle reached from one end of a row
    only the seat count then may be limited to 7 or 8
   In a continental arrangement all seats are located in a central section
    the maximum quantity of chairs per row can greatly exceed the limits
LAYOUT FORM TYPES
  End stage      Wide fan       ¾ Arena           Arena
AUDITORIUM SEATING DIMENSION
   Chair width 18” to 24” most commonly used 20”, 21”,22”inch
   Measured from centre to centre support legs
ROW SPACING
    The spacing provides marginal clearance between a seated person
     knees and the back of the chair in the next forward row at the same
     time it will require that a seated personstand to permit another
     personto get by them
    Minimum dimension 2’-6”(30”)
    Increasing the row spacing to 36”, seating comfort is improved &
     passage along a row of seated persons is accomplished with less
     disruption
    Flat or less steeply sloped floors will usually allow a person to extent
     their knees and legs under minimum row spacing conditions
    Example 12”high rise ,32”row spacing. It is necessary to consider
     increasing the back to back dimension to provide more leg room
    The free space under a chair is also lost when a row of seats is located
     directly behind a low wall in this case a recommended minimum
     clearance would be 11” measured from seat edge in the lower position
     of wall
    As the floor slope is increased free space diminishes
VISIBILITY
    Sightlines require both horizontal and vertical sightlines
NBC
   Clear aisles not greater than 1.2m in width
   Seats not more than 7 seats away from an aisle at one end
   All these aisles do not direcly meet exit doors cross aisles shall be
    provided parallel to line of seating so as to provide direct access to
    exit.provided that not more than one cross aisle for every 10 rows shall
    be required
   Width of cross aisle minimum 1m
   Door width and door height not greater than 2m
   Exit door width not greater than 2m
PARKING
              Bus turning radius                  car turning radius
   Parking spaces   parallel parking     90 degree parking   30 degree parking
45 degree parking    60 degree parking    90           30     45           60
RESOURCE CENTRE
CLASSROOMS