Green Wall

This document provides specifications for a living wall system including: - GSKY Versa XT frames made of 304 stainless steel - GSKY Versa XT trays with selected plants - GSKY 3/4" supply line and nutrient injector - 100mm and 152mm stainless steel trim for the top, sides and bottom - The wall must be installed on a concrete or CMU wall that can support a load of 30lbs/sqft.

Uploaded by

Raja Sudhan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
263 views5 pages

Green Wall

This document provides specifications for a living wall system including: - GSKY Versa XT frames made of 304 stainless steel - GSKY Versa XT trays with selected plants - GSKY 3/4" supply line and nutrient injector - 100mm and 152mm stainless steel trim for the top, sides and bottom - The wall must be installed on a concrete or CMU wall that can support a load of 30lbs/sqft.

Uploaded by

Raja Sudhan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

GSKY 100MM SS 304 TOP TRIM

VERSA DRIPLINE

WATERPROOFING BY OTHERS

GSKY VERSA XT (304 SS) FRAME

GSKY 3/4" SUPPLY LINE

GSKY VERSA XT TRAYS

GSKY NUTRITIENT INJECTOR

GSKY 152MM SS 304 BOTTOM TRIM

GSKY 100MM SS 304 SIDE TRIM

ABOVE THE GROUND / FRAME OPTION


XAF-64
VARIES 330 330
100 899 - 5 POTS TRAY WIDETH 381 - 2 POTS TRAY WIDETH 100 2
GX-3.0 GSKY SS 304 BRUSHED

100
GSKY SS 304 BRUSHED FINISH TOP TRIM
FINISH TOP TRIM

GSKY SS 304 BRUSHED


FINISH SIDE TRIM

227
GSKY SS 304 BRUSHED
FINISH SIDE TRIM GSKY VERSA XT (T304 SS)
FRAME

GSKY VERSA XT TRAY WITH FASTENER TYPE TBD BY GSKY


SELECTED PLANTS FOR EACH PROJECT

VARIES
VARIES WATERPROOFING ON WALL
SURFACE BY OTHERS

VERSA DRIPLINE TO BE
INSTALLED FOR EVERY 5
ROWS OR LESS

CONCRETE WALL (FULLY


GROUTED CMU WALL)
2 STRUCTURE BY OTHERS;
GSKY SS 304 BRUSHED WALL MUST SUPPORT
GX-3.0
FINISH REMOVABLE TRIM 30lb/sq.ft. SYSTEM WEIGHT

152
152

GSKY 1" DRAIN PIPE

1" DRAIN PIPE STUBOUT


BY OTHERS; COPPER OR
PEX PIPE REQUIRED

TBD
TBD

ELEVATION SECTION SIDE


1 SCALE: 1:30
3 SCALE: 1:30
4 SCALE: 1:30
CONCRETE WALL (FULLY GROUTED
CMU WALL) STRUCTURE BY
OTHERS; WALL MUST SUPPORT
30lb/sq.ft. SYSTEM WEIGHT
WATERPROOFING ON WALL
SURFACE BY OTHERS
VERSA XT (T304 SS) FRAME
FASTENER TYPE TBD BY
GSKY FOR EACH PROJECT

GSKY SS 304 BRUSHED


FINISH SIDE TRIM

GSKY VERSA XT TRAY WITH


SELECTED PLANTS
LINE OF REMOVABLE
TRIM BELOW 1 1
GX-3.0 GX-3.0

PLAN
2 SCALE: 1:30

SERVICE
100 SIDE/TOP
< 8' OK
lb At ICU At ICU At ICU

XAF-64 GENERAL OVERVIEW 152 BOTTOM


AUTOMATED +
WALL
+
WALL
+
WALL
< 13' OK

> 13'
OK

OK OK OK GX 1.0
VER. 1.1 297x420 mm (A3) SYSTEM WEIGHT TRIM REMOTE ICU IRRIGATION MAINT. ACCESS
Versa XT wall system weight SS brushed finish or Require GSky's consultation Walls over 40' / 12m need additional
= 30 lb/sq.ft / 146 kg/sq.m. powder coated aluminum for > 35' / 10.5 m height wall considerations. See GSky
See gsky.com for details. or > 100' / 30.5 m wide wall. maintenance manual.
SINGLE ZONE MAX. 9150 3/4" WATER SUPPLY WITH 3/4" FIPT
FROM ICU ROOM BY OTHERS;
STUB-OUT MUST BE TERMINATED

VERSA DRIPLINE TO BE INSTALLED


WITH ELBOW FACING UP WITHIN
1-1/2" SPACE FROM THE WALL S
FOR EVERY 5 ROWS OR LESS

152
1" CONDUIT WITH FINISH LINE
FROM ICU BY OTHERS; STUB-OUT
MUST BE TERMINATED WITH
ELBOW FACING DOWN WITHIN
1-1/2" SPACE FROM THE WALL

250
VERSA DRIPLINE TO BE INSTALLED
FOR EVERY 5 ROWS OR LESS

GSKY 3/4" SUPPLY LINE


50

TBD
SINGLE ZONE MAX. 3650
WATER CASCADES
FROM TRAY TO TRAY

ELEVATION DETAIL
3 SCALE: 1:8
VERSA DRIPLINE TO BE INSTALLED STUB OUT ELBOWS MUST
FOR EVERY 5 ROWS OR LESS BE FIT WITHIN VERSA XT SS
FRAME (38mm) WIDTH

3/4" WATER SUPPLY WITH 3/4"


FIPT FROM ICU ROOM BY
OTHERS; STUB-OUT MUST BE
TERMINATED WITH ELBOW
3/4" WATER SUPPLY WITH 3/4" FIPT 38 FACING UP WITHIN 38mm
FROM ICU ROOM BY OTHERS; SPACE FROM THE WALL

152
STUB-OUT MUST BE TERMINATED
WITH ELBOW FACING UP WITHIN 1" CONDUIT WITH FINISH LINE
1-1/2" SPACE FROM THE WALL FROM ICU BY OTHERS; STUB-OUT
S MUST BE TERMINATED WITH
152

ELBOW FACING DOWN WITHIN


38mm SPACE FROM THE WALL
250

250
1" CONDUIT WITH FINISH LINE FROM
ICU BY OTHERS; STUB-OUT MUST BE GSKY 1" DRAIN PIPE
TERMINATED WITH ELBOW FACING
60

3
DOWN WITHIN 1-1/2" SPACE FROM
THE WALL -

60
GSKY 1" DRAIN PIPE WARNING! LOCATION OF STUBOUTS 1" DRAIN PIPE STUBOUT
1" DRAIN PIPE STUBOUT FOR WATER AND CONDUIT SUPPLY BY OTHERS; COPPER OR
BY OTHERS; COPPER OR TBD ARE CRITICAL AS IT DETERMINES THE PEX PIPE REQUIRED
PEX PIPE REQUIRED
50
LOCATION OF THE WALL.

TBD
ELEVATION
1 SECTION
SCALE: 1:20
2 SCALE: 1:8

SERVICE
100 SIDE/TOP
< 8' OK
lb At ICU At ICU At ICU

XAF-64 IRRIGATION OVERVIEW 152 BOTTOM


AUTOMATED +
WALL
+
WALL
+
WALL
< 13' OK

> 13'
OK

OK OK OK GX 2.0
VER. 1.1 297x420 mm (A3) SYSTEM WEIGHT TRIM REMOTE ICU IRRIGATION MAINT. ACCESS
Versa XT wall system weight SS brushed finish or Require GSky's consultation Walls over 40' / 12m need additional
= 30 lb/sq.ft / 146 kg/sq.m. powder coated aluminum for > 35' / 10.5 m height wall considerations. See GSky
See gsky.com for details. or > 100' / 30.5 m wide wall. maintenance manual.
*REQUIREMENTS:
*REQUIREMENTS:
*GSKY NUTRIENT INJECTOR - 184 ( mm) h x 560 (mm) w x 181 (mm) d
*GSKY NUTRIENT INJECTOR - 184 ( mm) h x 560 (mm) w x 181 (mm) d *19MM FIPT INLET / OUTLET
*19MM FIPT INLET / OUTLET *EASY ACCESS FOR MAINTENANCE
*EASY ACCESS FOR MAINTENANCE *ADEQUATE PRESSURE TO GET MIN 40 PSI AT GREEN WALL STUB-OUT(S)
*ADEQUATE PRESSURE TO GET MIN 40 PSI AT GREEN WALL STUB-OUT(S) *120V / 15AMP GFCI POWER RECEPTACLE
*120V / 15AMP GFCI POWER RECEPTACLE *BACK-FLOW PREVENTOR AS REQUIRED BY OTHERS (WITH DRAIN)
*BACK-FLOW PREVENTOR AS REQUIRED BY OTHERS (WITH DRAIN) *FLOOR DRAIN FOR MAINTENANCE
*FLOOR DRAIN FOR MAINTENANCE *WATER SUPPLY LINE FROM THE ICU TO WALL STUB-OUT(S) MUST BE FREEZE
*WATER SUPPLY LINE FROM THE ICU TO WALL STUB-OUT(S) MUST BE FREEZE PROTECTED FOR WINTER OPERATION
PROTECTED FOR WINTER OPERATION

1500
1500
560
560

MAIN WATER SUPPLY LINE TO


MAIN WATER SUPPLY LINE TO GSKY TIMER WITH LOCK
GSKY TIMER WITH LOCK GSKY NUTRIENT INJECTOR BY
GSKY NUTRIENT INJECTOR BY OTHERS
OTHERS DUAL RECEPTACLE (120 VAC;
DUAL RECEPTACLE (120 VAC; 15AMP) BY OTHERS
1" CONDUIT TO GREEN WALL 15AMP) BY OTHERS
BY OTHERS 1" CONDUIT TO GREEN WALL HARD WIRE POWER CONNECTION
HARD WIRE POWER CONNECTION BY OTHERS (120 VAC; 15 AMPS) BY OTHERS
(120 VAC; 15 AMPS) BY OTHERS
GSKY 3/4" PUSH & FIT
GSKY 3/4" PUSH & FIT BALL BALL VALVE
VALVE GSKY VALVE ASSEMBLY GSKY NUTRIENT INJECTOR
GSKY NUTRIENT INJECTOR

184
(USE FOR ZONE VALVE)

184
WATER SUPPLY LINE FROM GSKY
VALVE ASSEMBLY(S) TO STUB-OUT
GSKY VALVE ASSEMBLY (USE FOR AT GREEN WALL BY OTHERS
ZONE VALVE)

1500
1500
WATER SUPPLY LINE FROM GSKY
VALVE ASSEMBLY(S) TO STUB-OUT
AT GREEN WALL BY OTHERS

1000
1000
ADDITIONAL ZONE VALVES
AS REQUIRED BY GSKY

FLOOR DRAIN BY OTHERS


FLOOR DRAIN BY OTHERS

IRRIGATION CONTROL UNIT (ZONE VALVE AT ICU) IRRIGATION CONTROL UNIT (ZONE VALVE AT GREEN WALL)
1 SCALE 1:16
2 SCALE 1:16

SERVICE
100 SIDE/TOP
< 8' OK
lb At ICU At ICU At ICU

XAF-64 IRRIGATION SYSTEM 152 BOTTOM


AUTOMATED +
WALL
+
WALL
+
WALL
< 13' OK

> 13'
OK

OK OK OK GX 2.1
VER. 1.1 297x420 mm (A3) SYSTEM WEIGHT TRIM REMOTE ICU IRRIGATION MAINT. ACCESS
Versa XT wall system weight SS brushed finish or Require GSky's consultation Walls over 40' / 12m need additional
= 30 lb/sq.ft / 146 kg/sq.m. powder coated aluminum for > 35' / 10.5 m height wall considerations. See GSky
See gsky.com for details. or > 100' / 30.5 m wide wall. maintenance manual.
330

36 256 38

GSKY SS 304 BRUSHED


FINISH TOP TRIM

CONCRETE WALL (FULLY


GROUTED CMU WALL)
STRUCTURE BY OTHERS;
WALL MUST SUPPORT
30lb/sq.ft. SYSTEM WEIGHT

100
VERSA DRIPLINE

WATERPROOFING BY
OTHERS ON WALL
SURFACE BY OTHERS

± 227
GSKY VERSA XT TRAY
WITH SELECTED PLANTS

FASTENER TYPE TBD BY GSKY


FOR EACH PROJECT
CONCRETE WALL (FULLY
GROUTED CMU WALL) STRUCTURE WATER CASCADES FROM
BY OTHERS; WALL MUST SUPPORT TRAY TO TRAY
30lb/sq.ft. SYSTEM WEIGHT

WATERPROOFING ON WALL
SURFACE BY OTHERS
3/4" WATER SUPPLY WITH 3/4" FIPT
FROM ICU ROOM BY OTHERS;
STUB-OUT MUST BE TERMINATED
WITH ELBOW FACING UP WITHIN 3/4" WATER SUPPLY WITH 3/4"
38mm SPACE FROM THE WALL FIPT FROM ICU ROOM BY
OTHERS; STUB-OUT MUST BE
GSKY VERSA XT FRAME TERMINATED WITH ELBOW
(T304 SS) FACING UP WITHIN 1-1/2"
SPACE FROM THE WALL
FASTENER TYPE TBD BY GSKY
FOR EACH PROJECT GSKY VERSA XT (T304 SS)
FRAME

227 TYP.
38
GSKY 3/4" SUPPLY LINE
1" CONDUIT WITH FINISH LINE
FROM ICU BY OTHERS;
STUB-OUT MUST BE TERMINATED
WITH ELBOW FACING DOWN
WITHIN 38mm SPACE FROM THE
GSKY SS 304 BRUSHED WALL
FINISH SIDE TRIM BY

330
256
GSKY SS 304 BRUSHED

45
TBD
FINISH REMOVABLE TRIM

GSKY 1" DRAIN PIPE

152
VERSA XT TRAY WITH
SELECTED PLANTS

36
1" DRAIN PIPE STUBOUT
LINE OF REMOVABLE BY OTHERS; COPPER OR
TRIM BELOW PEX PIPE REQUIRED

TBD
100

PLAN DETAIL SECTION DETAIL


1 SCALE: 1:8
2 SCALE: 1:8

SERVICE
100 SIDE/TOP
< 8' OK
lb At ICU At ICU At ICU

XAF-64 DETAILS 152 BOTTOM


AUTOMATED +
WALL
+
WALL
+
WALL
< 13' OK

> 13'
OK

OK OK OK GX 3.0
VER. 1.1 297x420 mm (A3) SYSTEM WEIGHT TRIM REMOTE ICU IRRIGATION MAINT. ACCESS
Versa XT wall system weight SS brushed finish or Require GSky's consultation Walls over 40' / 12m need additional
= 30 lb/sq.ft / 146 kg/sq.m. powder coated aluminum for > 35' / 10.5 m height wall considerations. See GSky
See gsky.com for details. or > 100' / 30.5 m wide wall. maintenance manual.

You might also like