Sejadi Modification Platfrom Project                                                                             Data Sheet for Thermoelectric Generator
Sejadi STS Platform                                                                                                    SP-SJ-ELE-DAS-CV X-000-00001-00
Date: 2-Mar-2015                                                                                                                                 Rev U
Client Chevron Indonesia Company                          Engineering Org.-                                    Spec.No. SP-SJ.ELE.SPC-CVX-000-00001-00
Project Location East Kalimantan                          Specifier Name Nll                                   Equipment No.
Project No.Nil                                                                                                 P.O.No.
  1     SERVICE CONFITIONS                                                                                                VENDOR NOTE’S
1.1     Applicable Standard               : UL, NEC
1.2     Drawing References                :
1.3     Other Related Doc                 :
 2      SERVICE CONFITIONS                                                                                                VENDOR NOTE’S
2.1     Location                          :      Indoor             Outdoor            Dusty
2.2     Design Ambient Temperatur         : Min: 70oF/ 21oC               Max: 95oF/ 35oC
2.3     Relative Humidity                 : Max: 95%
2.4     Altitude (above mean sea level)   : 51 Feet
2.5     Design Wind Velocity              : 100mph
2.6     Earthquake Seismic Zone           : 2
           PARTICULARS OF EQUIPMENT                       UNITS                  REQUIREMENT                             VENDOR RESPONSE
 3      THERMO ELECTRIC GENERATOR
3.1    Vendor                                                                 Global Thermoelectric
3.2    Product Type                                                                    STA
3.3    Mounting Type                                                              Free Standing
3.4    Dimension (L x W x D)                               inch                        STA
3.5    Total Wight                                            Lbs                      STA
3.6    Classification Area                                              Class 1 Division 1, Group D, T3A
3.7    Enclosure Material                                                            SS 316L
3.8    Ingress of Protection                                                       NEMA 4x/7
3.9    Cooling System                                                          Natural Convection
3.10 Color                                                                    Manufacture Standard
3.11 Voltage Output                                                                24 – 30 VDC
3.12 Electrical Measurement                                               Voltmeter and Ampermeter
3.13 Electrical Protection                                                        Blocking Diode
3.14                                                                           DC Voltage Regulator
3.15                                                                    ThEG Failure Dry Contact Alarm
3.16 Power Rating at amb temp 70oF anda 24 VDC            Watt                   100 (Note 3,4,5)
3.17 Power Rating at 20 years usage and 95oF amb temp     Watt                   STA (Note 3,4,5)
 4      MISCELLANEOUS
4.1    Isolator Switch Junction Box
4.2         Dimension (L x W x D)                          inch                        STA
4.3         Mounting                                                              Wall Mounting
4.4         Total Weight                                      Lbs                      STA
4.5         Classification Area                                           Class 1 Zone 1, Group D, T3A
4.6         Enclosure Material                                            Copper Free Cast Aluminum
4.7         Ingress of Protection                                                      IP 56
4.8         Type of Protection                                                        AeX’d’
4.9         Bus Bar Material                                                         Copper
4.10        Rated Busbar Current                                                     50 Amp
4.11        Indication Lamp:                                                       LED Cluster
4.12               On                                                                  Red
4.13        Electrical Protection                                       Over Current (On Load Fuse Isolator)
4.14        Lockable by Padlock                           Yes/No                  Yes, Required
4.15    Voltage Regulator Junction Box
4.16        Dimension (L x W x D)                          Inch                        STA
4.17        Mounting                                                              Wall Mounting
4.18        Total Weight                                      Lbs                      STA
4.19        Classification Area                                           Class 1 Zone 1, Group D, T3A
4.20        Enclosure Material                                            Copper Free Cast Aluminum
Sejadi Modification Platfrom Project                                                                           Data Sheet for Thermoelectric Generator
Sejadi STS Platform                                                                                                   SP-SJ-ELE-DAS-CV X-000-00001-00
Date: 2-Mar-2015                                                                                                                                Rev U
Client Chevron Indonesia Company                             Engineering Org.-                               Spec.No. SP-SJ.ELE.SPC-CVX-000-00001-00
Project Location East Kalimantan                             Specifier Name Nll                              Equipment No.
Project No.Nil                                                                                               P.O.No.
            PARTICULARS OF EQUIPMENT                          UNITS                                                    VENDOR RESPONSE
  4    MISCELLANEOUS – Contd’
4.21      Ingress of Protection                                                        IP 56
4.22        Type of Protection                                                        AEx’d’
4.23        Voltage Regulator Rated Power                                            250 Watt
4.24        Indication Lamp:                                                        LED Cluster
4.25              On                                                                    RED
4.26        Electrical Protection                                                   2 Pole, MCB
4.27        Metering Indication                                                      Volt, Amp
4.28   DC Distribution Board
4.29        Dimension (L x W x D)                              Inch                     STA
4.30        Mounting                                                               Wall Mounting
4.31        Total Weight                                       Lbs                      STA
4.32        Classification Area                                            Class 1 Zone 1, Group D, T3A
4.33        Enclosure Material                                              Copper Free Cast Aluminum
4.34        Ingress of Protection                                                      IP 56
4.35        Type of Protection                                                         AEx’d’
4.36        Bus Bar Material                                                          Copper
4.37        Rated Busbar Current                                                      50 Amp
4.38        Indication Lamp:                                                        LED Cluster
4.39              On                                                                    Red
4.40              Fault                                                                Yellow
4.41        Metering Indication                                                      Volt, Amp
4.42        Lockable by Padlock                              Yes/No                Yes, Required
4.43        Surge Arrestor                                   Yes/No                Yes, Required
4.44        Automatic Insulation Fault Locator               Yes/No                Yes, Required
4.45        Electrical Protection                                                 Reverse Current
4.46                                                                                Short Circuit
4.47                                                                              Thermal Overload
 5     NOTES
 1     STA = Vendor To Advise, TBA = To Be Advise;
 2     Vendor shall provide gas conditioning system to treat COMPANY fuel gas composition (attachment-1) into package fuel gas specification,
       which is complete with overpressure protection system which comply to API 14C. The fuel gas treatment and associated protection device
       shall be rated to 150# ANSI rating class
 3     Vendor shall confirm and warrant maximum and minimum rated continuos power at site ambient temperature and site available fuel gas
       characteristic
 4     Vendor shall advice output power rating for new condition and identify ageing factor after 20 year usage
 5     Vendor shall take into consideration losses power up to downstream connected load and warrant minimum continuous power 80 watt at
       95oF(35oC)
 6     Thermoelectric Generator shall be designed for continuous operation with minimal maintenance or human intervention, required
       maintenance intervals and duration shall be indentified in Vendor documentation
 7     Vendor shall ensure that external surface enclosure ThEG package temperature not exceed 140Of (60Oc) in any condition
 8     Vendor shall ensure reliability and rating of each component inside distribution board cause of explosion proof type distribution board will
       derate their capacity
 9     Vendor shall provide engineering calculation in regard selecting of each equipment such as on load fuse isolator, incomer MCB, etc for
       COMPANY approval
 10    Voltage Regulator / DC to FC converter shall having minimum 90% efficiency, EMI according to IEC 61000 Class A, and having minimum MTBF
       100,000h
 11    Vendor shall provide all necessary instrumentation accessories required such as valve, union, tubing, etc for package TEG
 12    Vendor shall provide all necessary stainless steel 316L bolt nut for equipment mounting purpose