Vega Lite Specification PDF
Vega Lite Specification PDF
• 1 to 11 outputs
• Voltages from 1.8 to 56V
• Current up to 60 Amps
• Worldwide approvals & CB report
• Medical approval option
• 3 Year Warranty
Key Market Segments & Applications
Instrumentation Broadcast
Vega-Lite Series
Medical ATE
Automation Industrial Computing
550 - 900 Watts Security Lifesciences/Laboratory
Modular power solution Network Servers and Routers
INPUT 1000
Maximum Continuous Output Power
Leakage Current 1.5mA max at 264Vac & 63Hz 300 Vega Lite 750
0
80 100 120 140 160 180 200 220 240 260 280
ac Input Voltage
OUTPUT
Voltage / Current See module tables
Turn on Delay 1.5s max at 90Vac & 100% rated output power
Rise Time <50ms to 90% of voltage, monotonic rise above 10%
Turn on Overshoot <5% or 250mV Load type dependant, no overshoot with resistive load
Efficiency 75% typical at 230Vac & 100% rated power, configuration dependent
Hold up 16ms min at 100Vac & 100% rated output power
Ripple & Noise <1% (or 50mV if higher) Pk- Pk, using EIAJ test method & 20MHz bandwidth
Voltage Accuracy <1% of set Voltage
Standard on single output modules, max 0.75V total line drop
Remote Sense Yes
Option for twin output modules
Minimum Load No on any output
Temperature Coefficient <0.02% of rated voltage per °C
Load Regulation <0.5% or 25mV for 0-100% load change
Line Regulation <0.1% for 100 - 264Vac input change
Cross Regulation <0.2% for 100% load change on any other output
<6% or 300mV of set voltage for 50% load change (above 25% load)
Transient Response Recovery
500µs for recovery to 1% or 100mV of set voltage
120 - 130% of set voltage for outputs > 4.1V (Tracking OVP)
Over Voltage Protection 140 - 150% of set voltage for outputs < 4.1V (Tracking OVP)
120 - 150% of max rated output (Fixed OVP)
Over Current Protection 105 - 125% of rated current, constant current characteristic
Short Circuit Protection <150% of rated current, when output voltage <1%
Over Temperature Protection Yes Shuts down all outputs and fan. Cycle ac off / on to reset
Note 1 shutdown temp varies according to ambient, output power and input V
2 ac fail signal (if fitted) provides 5ms warning of thermal shutdown
ISOLATION
Input to Output Reinforced 4kV (ac), 5.7kV (dc) type tested, production tested to 4.3kVdc.
Input to Earth Basic 2.3 kV (dc) Output to Output / Output to Earth Operational 200 V (dc)
EMISSIONS BS EN61000-6-3:2001 (Residential, Commercial & Light Industrial Supply), also complies with BS EN61000-6-4:2001
See application note for details.
Radiated Electric Field EN55022 Class B (as per CISPR.22)
Only for ‘S’ type leakage versions
Only for ‘S’ type leakage versions.
Conducted Emissions EN55022 Class B (as per CISPR.22)
‘L’ types meet Class A
Conducted Harmonics EN61000-3-2 Compliant to Class A
Flicker EN61000-3-3 Compliant
ENVIRONMENT
Temperature 0° to 65° operational, -40° to 70°C storage (max 12 months)
The extensive range of output modules and options make it possible to achieve all popular combinations of Volts and Amps. The ‘online’ con-
figurator is the best way to achieve the optimum configuration, however you can also create your own Vega configuration from this datasheet
by using the guide below.
Web Configurator
1 Visit http://www.emea.tdk-lambda.com, select ‘Vega Configurator’ and follow the online instructions.
2 Enter your required Volts / Amps, and any additional functions (if required)
3 Enter preferred type of cooling, input connection, lower leakage current (if required) and controls & signal functions, (if required)
4 Configurator will select the most suitable modules and options and give a unique part number.
2 Select Output Modules and Options from the Available Output Voltages tables.
Output V5 550W
Power
V5 F S S F
V7 750W
Input
S Screw terminal
Connection
Ensure you do not select more than a total of 5 slots width of module. This will create a complete product description eg:-
V5FSSF 5L1SN 12/12H3/3S 24C5S which represents a four output 550W Vega with Forward air, Screw input terminals, 1.5mA Earth Leak-
age, ac Fail, Global Inhibit & 5V / 100mA aux supply.
Output 1 = 5V / 35A with output inhibit, Module Good and Current Share option
Output 2 = 12V / 10A
Output 3 = 12V / 6A
Output 4 = 24V / 10A
126.5
12.00
7.50 218.00 45.50
31.30
62.80
31.00
22.00
7.60
65.60
19.37
226.50
Press both tabs then
lever forward to remove
Reverse operation to
re-fit
19.00
92.00
.5 0
R4
Screw Terminal Case
18.35
270.65 (INCLUDING FAN GRILLE)
8 x M4 Customer fixings
Max thread penetration:- 4.5mm
PCB Centre
2.00
9 1
8.52
7.80
2.00
2
0
10
0 PCB Centre
5.15 SC Term
0 PCB Centre
LOCAL DISTRIBUTION