0% found this document useful (0 votes)
95 views11 pages

Tar-Ammonia Liquor Pump Data Sheet

This document provides technical specifications for three centrifugal pumps used in a tar-ammonia liquor separating unit. Pump 1 is used for flushing liquor and has three sets, with two sets for normal operation and one set for standby. Pumps 2 and 3 are also for flushing liquor but have two sets each, with one set for normal operation and one set for standby. The document lists design data for the pumps including flow rates, pressures, temperatures, materials, and drive details. It also provides installation and construction details.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
95 views11 pages

Tar-Ammonia Liquor Pump Data Sheet

This document provides technical specifications for three centrifugal pumps used in a tar-ammonia liquor separating unit. Pump 1 is used for flushing liquor and has three sets, with two sets for normal operation and one set for standby. Pumps 2 and 3 are also for flushing liquor but have two sets each, with one set for normal operation and one set for standby. The document lists design data for the pumps including flow rates, pressures, temperatures, materials, and drive details. It also provides installation and construction details.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

ACRE COKING & SHEET 1 OF 1 Rev.

00
REFRACTORY ENGINEERING TECHNICAL DATA SHEET
Tar-ammonia Liquor Separating Unit
CONSULTING
CORPORATION(DALIAN), MCC PROJ.- NO. :
CENTRIFUGAL PUMP
ACRE-NO. PROJECT: TSK COBP-3,4
1 Use : Flushing liquor pump No. of set: 3 sets Item-No.: 2P41401ABC
2 Normal operation : 2 sets Standby : 1 set
3 Standards :
4 Design data Meteorological and site condition
5 Medium Ammonia water Flow rate 1900 m3/h Altitude above sea level 60m

Seismic condition:
6 Tar
Zone –III as per BIS: 1893
7 Corrosion by Ammonia water Suction pressure 0.08 MPa(g) Atmosphere temperature 17.4~44℃
8 Operating temper at.(normal) 70℃ Atmospheric pressure average 100.63kPa
9 Operating temper at. (max.) 78℃ Pressure head (liquid) 50 m Relative humidity 45~85%
10 Density at t (normal) 998kg/m3 Efficiency estimated
11 Viscosity at. (normal) 0.406mPa.s rating at shaft estimated
12 Vapor press. at.(normal) 0.039MPa(a) Mode of operation continue.
13 Solidification point ℃ NPSH required m
14
15
16 Construction Installation condition Shaft sealing
17 Type Centrifugal pump Location Outdoors single mechanical seal
18 Position of shaft Horizontal Hazard environment / Self-Flushing
19 Impeller type Close
20
21
22 Material Spare part(equipment supply) Other
23 Pump casing S30408 Mechanical seal
24 Impeller S30408
25
26
27 Drive Other
28 Drive E-motor Speed rpm
29 Voltage 6.6 kV Phase 3
30 Frequency 50 Hz Rating estimated 400 kW
31 Ex. Protection / Type of protection IP55
32 Insulation grade F Heater 205W
33 Vary frequency
34
35
36 Remarks : (1) Standard for nozzles:ASME B16.5
37 (2) Base bolt for installation supplied with pump
38 (3) Inlet and outlet pipe flanges, gaskets, bolts supplied with pump
39 (4) Flushing metal tube, flow meter, valves, pressure gauge of mechanical seal supplied with pump
40 (5) DCS monitor signal: Open/Close, Run/Error,1-way Comprehensive Alarm
41 (6) No use cuprum, zincum
42 (7) Other requirements see appendix <General requirement of process electrical and instrument>
43
44

DESED.BY: CHKED.BY: EXAMD.BY: TSL DWG. NO.:TSP-04-02-62-11-018-001


ACRE COKING & SHEET 1 OF 1 Rev. 00
REFRACTORY ENGINEERING TECHNICAL DATA SHEET
Tar-ammonia Liquor Separating Unit
CONSULTING
CORPORATION(DALIAN), MCC PROJ.- NO. :
CENTRIFUGAL PUMP
ACRE-NO. PROJECT: TSK COBP-3,4
1 Use : Flushing liquor pump No. of set : 2 sets Item-No.: 2P41401DE
2 Normal operation : 0 set Standby : 2 sets
3 Standards :
4 Design data Meteorological and site condition
5 Medium tar ammonia mix liquor Flow rate 1900 m3/h Altitude above sea level 60 m
Seismic condition:
6 Tar
Zone – III as per BIS: 1893
7 Corrosion by tar ammonia mix liquor Suction pressure 0.08 MPa(g) Atmosphere temperature 17.4~44℃
8 Operating temper at.(normal) 70℃ Atmospheric pressure average 100.63kPa
9 Operating temper at. (max.) 78℃ Pressure head (liquid) 50 m Relative humidity 45~85%
10 Density at.(normal) 998kg/m3 Efficiency estimated
11 Viscosity at. (normal) 0.406mPa.s rating at shaft estimated
12 Vapor press. at. (normal) 0.039MPa(a) Mode of operation intermittent.
13 Solidification point ℃ NPSH required m
14
15
16 Construction Installation condition Shaft sealing
17 Type Centrifugal pump Location Outdoors single mechanical seal
18 Position of shaft Horizontal Hazard environment / Self-Flushing
19 Impeller type Close
20
21
22 Material Spare part(equipment supply) Other
23 Pump casing S30408 Mechanical seal
24 Impeller S30408
25
26
27 Drive Other
28 Drive Diesel engine Speed rpm
29 Voltage / Phase /
30 Frequency / Rating estimated /
31 Ex. Protection / Type of protection /
32 Insulation grade / Heater No
33 Vary frequency
34
35
36 Remarks : (1) Standard for nozzles:ASME B16.5
37 (2) Base bolt for installation supplied with pump
38 (3) Inlet and outlet pipe flanges, gaskets, bolts supplied with pump
39 (4) Flushing metal tube, flow meter, valves, pressure gauge of mechanical seal supplied with pump
40 (5) DCS monitor signal: Open/Close, Run/Error,1-way Comprehensive Alarm
41 (6) No use cuprum, zincum
42 (7) Other requirements see appendix <General requirement of process electrical and instrument>
43
44

DESED.BY: CHKED.BY: EXAMD.BY: TSL DWG. NO.:TSP-04-02-62-11-018-001


ACRE COKING & SHEET 1 OF 1 Rev. 00
REFRACTORY ENGINEERING TECHNICAL DATA SHEET
Tar-ammonia Liquor Separating Unit
CONSULTING
CORPORATION(DALIAN), MCC PROJ.- NO. :
CENTRIFUGAL PUMP
ACRE-NO. PROJECT: TSK COBP-3,4
1 Use : Coal water pump No. of set : 2 sets Item-No.:2P41402AB
2 Normal operation : 1 set Standby : 1 set
3 Standards :
4 Design data Meteorological and site condition
5 Medium Ammonia water Flow rate 75 m3/h Altitude above sea level 60 m

Seismic condition:
6 Tar
Zone –III as per BIS: 1893
7 Corrosion by Ammonia water Suction pressure 0.05 MPa(g) Atmosphere temperature 17.4~44℃
8 Operating temper at.(normal) 70℃ Atmospheric pressure average 100.63kPa
9 Operating temper at. (max.) 78℃ Pressure head (liquid) 54m Relative humidity 45~85%
10 Density at . (normal) 998kg/m3 Efficiency estimated
11 Viscosity at. (normal) 0.406mPa.s rating at shaft estimated
12 Vapor press. at. (normal) 0.039MPa(a) Mode of operation continue.
13 Solidification point ℃ NPSH required m
14
15
16 Construction Installation condition Shaft sealing
17 Type Centrifugal pump Location Outdoors single end face mechanical seal
18 Position of shaft Horizontal Hazard environment / Self-Flushing
19 Impeller type Close
20
21
22 Material Spare part(equipment supply) Other
23 Pump casing Cast steel Mechanical seal
24 Impeller Cast steel
25
26
27 Drive Other
28 Drive E-motor Speed 1480 rpm
29 Voltage 415 V Phase 3
30 Frequency 50 Hz Rating estimated 37 kW
31 Ex. Protection / Type of protection IP55
32 Insulation grade F Heater No
33 Vary frequency
34
35
36 Remarks : (1) Standard for nozzles:ASME B16.5
37 (2) Base bolt for installation supplied with pump
38 (3) Inlet and outlet pipe flanges, gaskets, bolts supplied with pump
39 (4) Flushing metal tube, flow meter, valves, pressure gauge of mechanical seal supplied with pump
40 (5) DCS monitor signal: Open/Close, Run/Error,1-way Comprehensive Alarm
41 (6) No use cuprum, zincum
42 (7) Other requirements see appendix <General requirement of process electrical and instrument>
43
44

DESED.BY: CHKED.BY: EXAMD.BY: TSL DWG. NO.:TSP-04-02-62-11-018-001


ACRE COKING & SHEET 1 OF 1 Rev. 00
REFRACTORY ENGINEERING TECHNICAL DATA SHEET
Tar-ammonia Liquor Separating Unit
CONSULTING
CORPORATION(DALIAN), MCC PROJ.- NO. :
CENTRIFUGAL PUMP
ACRE-NO. PROJECT: TSK COBP-3,4
1 Use : Tar pump No. of set: 2 sets Item-No.:2P41403AB
2 Normal operation : 1 set Standby : 1 set
3 Standards :
4 Design data Meteorological and site condition
5 Medium tar Flow rate 30m3/h Altitude above sea level 60 m

Seismic condition:
6 Tar
Zone –III as per BIS: 1893
7 Corrosion by tar Suction pressure 0.04 MPa(g) Atmosphere temperature 17.4~44℃
8 Operating temper at.(normal) 70℃ Atmospheric pressure average 100.63kPa
9 Operating temper at. (max.) 78℃ Pressure head (liquid) 45 m Relative humidity 45~85%
10 Density at. (normal) 1150kg/m3 Efficiency estimated
11 Viscosity at.(normal) 38.8mPa.s rating at shaft estimated
12 Vapor press. at.(normal) 0.002MPa(a) Mode of operation continue.
13 Solidification point ℃ NPSH required m
14
15
16 Construction Installation condition Shaft sealing
17 Type Centrifugal pump Location Outdoors single mechanical seal
18 Position of shaft Horizontal Hazard environment / Self-Flushing
19 Impeller type Close
20
21
22 Material Spare part(equipment supply) Other
23 Pump casing Cast steel Mechanical seal
24 Impeller Cast steel
25
26
27 Drive Other
28 Drive E-motor Speed 1450 rpm
29 Voltage 415 V Phase 3
30 Frequency 50 Hz Rating estimated 18.5 kW
31 Ex. Protection / Type of protection IP55
32 Insulation grade F Heater No
33 Vary frequency
34
35
36 Remarks : (1) Standard for nozzles:ASME B16.5
37 (2) Base bolt for installation supplied with pump
38 (3) Inlet and outlet pipe flanges, gaskets, bolts supplied with pump
39 (4) Flushing metal tube, flow meter, valves, pressure gauge of mechanical seal supplied with pump
40 (5) DCS monitor signal: Open/Close, Run/Error,1-way Comprehensive Alarm
41 (6) No use cuprum, zincum
42 (7) Other requirements see appendix <General requirement of process electrical and instrument>
43
44

DESED.BY: CHKED.BY: EXAMD.BY: TSL DWG. NO.:TSP-04-02-62-11-018-001


ACRE COKING & SHEET 1 OF 1 Rev. 00
REFRACTORY ENGINEERING TECHNICAL DATA SHEET
Tar-ammonia Liquor Separating Unit
CONSULTING
CORPORATION(DALIAN), MCC PROJ.- NO. :
SUBMERGED PUMP
ACRE-NO. PROJECT:TSK COBP-3,4
1 Use : Slop pump No. of set : 2 sets Item-No.: 2P41404AB
2 Normal operation : 1 set Standby : 1 set
3 Standards :
4 Design data Meteorological and site condition
5 Medium tar ammonia mix liquor Flow rate 24 m3/h Altitude above sea level 60 m

Seismic condition:
6 Tar
Zone –III as per BIS: 1893
7 Corrosion by tar ammonia mix liquor Suction pressure 0.08 MPa(g) Atmosphere temperature 17.4~44℃
8 Operating temper at.(normal) 25℃ Atmospheric pressure average 100.63kPa
9 Operating temper at. (max.) 30℃ Pressure head (liquid) 28 m Relative humidity 45~85%
10 Density at. (normal) 1050kg/m3 Efficiency estimated
11 Viscosity at. (normal) 4.2mPa.s rating at shaft estimated
12 Vapor press. at. (normal) 0.039MPa(a) Mode of operation intermittent.
13 Solidification point ℃ NPSH required m
14
15
16 Construction Installation condition Shaft sealing
17 Type Centrifugal pump Location Outdoors single mechanical seal
18 Position of shaft Vertical Hazard environment / Flushing with ammonia water (0.45 MPa)
19 Impeller type Close
20
21
22 Material Spare part(equipment supply) Other
23 Pump casing S30408 Packing seal Insert depth(Inc.filler) 1850 mm
24 Impeller S30408
25
26
27 Drive Other
28 Drive E-motor Speed 1450 rpm
29 Voltage 415 V Phase 3
30 Frequency 50 Hz Rating estimated 7.5 kW
31 Ex. Protection dIIBT1 Type of protection IP55
32 Insulation grade F Heater No
33 Vary frequency
34
35
36 Remarks : (1) Standard for nozzles:ASME B16.5
37 (2) Base bolt for installation supplied with pump
38 (3) Inlet and outlet pipe flanges, gaskets, bolts supplied with pump
39 (4) Flushing metal tube, flow meter, valves, pressure gauge of mechanical seal supplied with pump
40 (5) DCS monitor signal: Open/Close, Run/Error,1-way Comprehensive Alarm
41 (6) No use cuprum, zincum
42 (7) Other requirements see appendix <General requirement of process electrical and instrument>
43
44

DESED.BY: CHKED.BY: EXAMD.BY: TSL DWG. NO.:TSP-04-02-62-11-018-001


ACRE COKING & SHEET 1 OF 1 Rev. 00
REFRACTORY ENGINEERING TECHNICAL DATA SHEET
Tar-ammonia Liquor Separating Unit
CONSULTING
CORPORATION(DALIAN), MCC PROJ.- NO. :
CENTRIFUGAL PUMP
ACRE-NO. PROJECT: TSK COBP-3,4
1 Use : Intermediate tar pump No. of set: 2 sets Item-No.:2P41406AB
2 Normal operation : 1 set Standby : 1 set
3 Standards :
4 Design data Meteorological and site condition
5 Medium tar Flow rate 30 m3/h Altitude above sea level 60 m

Seismic condition:
6 Tar
Zone –III as per BIS: 1893
7 Corrosion by tar Suction pressure 0.1 MPa(g) Atmosphere temperature 17.4~44℃
8 Operating temper at.(normal) 70℃ Atmospheric pressure average 100.63kPa
9 Operating temper at. (max.) 78℃ Pressure head (liquid) 28 m Relative humidity 45~85%
10 Density at.(normal) 1150kg/m3 Efficiency estimated
11 Viscosity at. (normal) 38.8mPa.s rating at shaft estimated
12 Vapor press. at. (normal) 0.002MPa(a) Mode of operation continue.
13 Solidification point ℃ NPSH required m
14
15
16 Construction Installation condition Shaft sealing
17 Type Centrifugal pump Location Outdoors single mechanical seal
18 Position of shaft Horizontal Hazard environment / Flushing with ammonia water (0.45 MPa)
19 Impeller type Open
20
21
22 Material Spare part(equipment supply) Other
23 Pump casing Cast steel Mechanical seal
24 Impeller Cast steel
25
26
27 Drive Other
28 Drive E-motor Speed 1450 rpm
29 Voltage 415 V Phase 3
30 Frequency 50 Hz Rating estimated 11 kW
31 Ex. Protection / Type of protection IP55
32 Insulation grade F Heater No
33 Vary frequency
34
35
36 Remarks : (1) Standard for nozzles:ASME B16.5
37 (2) Base bolt for installation supplied with pump
38 (3) Inlet and outlet pipe flanges, gaskets, bolts supplied with pump
39 (4) Flushing metal tube, flow meter, valves, pressure gauge of mechanical seal supplied with pump
40 (5) DCS monitor signal: Open/Close, Run/Error,1-way Comprehensive Alarm
41 (6) No use cuprum, zincum
42 (7) Other requirements see appendix <General requirement of process electrical and instrument>
43
44

DESED.BY: CHKED.BY: EXAMD.BY: TSL DWG. NO.:TSP-04-02-62-11-018-001


ACRE COKING & SHEET 1 OF 1 Rev. 00
REFRACTORY ENGINEERING TECHNICAL DATA SHEET
Tar-ammonia Liquor Separating Unit
CONSULTING
CORPORATION(DALIAN), MCC PROJ.- NO. :
DRAIN PUMP
ACRE-NO. PROJECT: TSK COBP-3,4
1 Use : Drain pump No. of set : 1 set Item-No.:2P41407
2 Normal operation : 1 set Standby : 0 set
3 Standards :
4 Design data Meteorological and site condition
5 Medium Water Flow rate 8~14m3/h Altitude above sea level 60 m

Seismic condition:
6 Tar
Zone –III as per BIS: 1893
7 Corrosion by Ammonia water Suction pressure MPa(g) Atmosphere temperature 17.4~44℃
8 Operating temper at.(normal) 25℃ Atmospheric pressure average 100.63kPa
9 Operating temper at. (max.) 30℃ Pressure head (liquid) 12 m Relative humidity 45~85%
10 Density at. (normal) 998kg/m3 Efficiency estimated
11 Viscosity at . (normal) 1 mPa.s rating at shaft estimated
12 Vapor press. at. (normal) MPa(a) Mode of operation intermittent.
13 Solidification point ℃ NPSH required m
14
15
16 Construction Installation condition Shaft sealing
17 Type Submerged pump Location Outdoors
18 Position of shaft Hazard environment /
19 Impeller type Close
20
21
22 Material Spare part(equipment supply) Other
23 Pump casing Cast Steel Insert depth(Inc.filler) 1430 mm
24 Impeller Cast Steel
25
26
27 Drive Other
28 Drive E-motor Speed 1450rpm
29 Voltage 415 V Phase 3
30 Frequency 50 Hz Rating estimated 2.2 kW
31 Ex. Protection dIIBT1 Type of protection IP55
32 Insulation grade F Heater No
33 Vary frequency
34
35
36 Remarks : (1) Standard for nozzles:ASME B16.5
37 (2) Base bolt for installation supplied with pump
38 (3) Inlet and outlet pipe flanges, gaskets, bolts supplied with pump
39 (4) Flushing metal tube, flow meter, valves, pressure gauge of mechanical seal supplied with pump
40 (5) DCS monitor signal: Open/Close, Run/Error,1-way Comprehensive Alarm
41 (6) No use cuprum, zincum
42 (7) Other requirements see appendix <General requirement of process electrical and instrument>
43
44

DESED.BY: CHKED.BY: EXAMD.BY: TSL DWG. NO.:TSP-04-02-62-11-018-001


ACRE COKING & SHEET 1 OF 1 Rev. 00
REFRACTORY ENGINEERING TECHNICAL DATA SHEET
Tar-ammonia Liquor Separating Unit
CONSULTING
CORPORATION(DALIAN), MCC PROJ.- NO. :
CENTRIFUGAL PUMP
ACRE-NO. PROJECT: TSK COBP-3,4
1 Use : Upper sprinkling pump No. of set : 2 sets Item-No.:2P41409AB
2 Normal operation : 1 set Standby : 1 set
3 Standards :
4 Design data Meteorological and site condition
5 Medium tar ammonia mix liquor Flow rate 180 m3/h Altitude above sea level 60m

Seismic condition:
6 Tar
Zone –III as per BIS: 1893
7 Corrosion by tar ammonia mix liquor Suction pressure 0.05 MPa(g) Atmosphere temperature 17.4~44℃
8 Operating temper at.(normal) 70℃ Atmospheric pressure average 100.63kPa
9 Operating temper at. (max.) 78℃ Pressure head (liquid) 60 m Relative humidity 45~85%
10 Density at.(normal) 1100kg/m3 Efficiency estimated
11 Viscosity at. (normal) 11.1mPa.s rating at shaft estimated
12 Vapor press. at. (normal) 0.039MPa(a) Mode of operation continue.
13 Solidification point ℃ NPSH required m
14
15
16 Construction Installation condition Shaft sealing
17 Type Centrifugal pump Location Outdoors single mechanical seal
18 Position of shaft Horizontal Hazard environment / Flushing with ammonia water (0.45 MPa)
19 Impeller type Close
20
21
22 Material Spare part(equipment supply) Other
23 Pump casing Cast steel Mechanical seal
24 Impeller Cast steel
25
26
27 Drive Other
28 Drive E-motor Speed 1450 rpm
29 Voltage 415 V Phase 3
30 Frequency 50 Hz Rating estimated 75 kW
31 Ex. Protection / Type of protection IP55
32 Insulation grade F Heater No
33 Vary frequency
34
35
36 Remarks : (1) Standard for nozzles:ASME B16.5
37 (2) Base bolt for installation supplied with pump
38 (3) Inlet and outlet pipe flanges, gaskets, bolts supplied with pump
39 (4) Flushing metal tube, flow meter, valves, pressure gauge of mechanical seal supplied with pump
40 (5) DCS monitor signal: Open/Close, Run/Error,1-way Comprehensive Alarm
41 (6) No use cuprum, zincum
42 (7) Other requirements see appendix <General requirement of process electrical and instrument>
43
44

DESED.BY: CHKED.BY: EXAMD.BY: TSL DWG. NO.:TSP-04-02-62-11-018-001


ACRE COKING & SHEET 1 OF 1 Rev. 00
REFRACTORY ENGINEERING TECHNICAL DATA SHEET
Tar-ammonia Liquor Separating Unit
CONSULTING
CORPORATION(DALIAN), MCC PROJ.- NO. :
CENTRIFUGAL PUMP
ACRE-NO. PROJECT: TSK COBP-3,4
1 Use : High pressure flushing liquor pump No. of set : 4 sets Item-No.: 2P41410ABCD
2 Normal operation : 2 set Standby : 2 set
3 Standards :
4 Design data Meteorological and site condition
5 Medium Ammonia water Flow rate 75 m3/h Altitude above sea level 60 m

Seismic condition:
6 Tar
Zone –III as per BIS: 1893
7 Corrosion by Ammonia water Suction pressure 0.01 MPa(g) Atmosphere temperature 17.4~44℃
8 Operating temper at.(normal) 70℃ Atmospheric pressure average 100.63kPa
9 Operating temper at. (max.) 78℃ Pressure head (liquid) 414 m Relative humidity 45~85%
10 Density at. (normal) 998kg/m3 Efficiency estimated
11 Viscosity at . (normal) 0.406mPa.s rating at shaft estimated
12 Vapor press. at. (normal) 0.039MPa(a) Mode of operation continue.
13 Solidification point ℃ NPSH required m
14
15
16 Construction Installation condition Shaft sealing
17 Type Centrifugal pump Location Outdoors single mechanical seal
18 Position of shaft Horizontal Hazard environment / Self-Flushing
19 Impeller type Close
20
21
22 Material Spare part(equipment supply) Other
23 Pump casing Cast steel Mechanical seal
24 Impeller Cast steel
25
26
27 Drive Other
28 Drive E-motor Speed 2980 rpm
29 Voltage 415 V Phase 3
30 Frequency 50 Hz Rating estimated 160 kW
31 Ex. Protection / Type of protection IP55
32 Insulation grade F Heater No
33 Vary frequency VVVF motor
34
35
36 Remarks : (1) Standard for nozzles:ASME B16.5
37 (2) Base bolt for installation supplied with pump
38 (3) Inlet and outlet pipe flanges, gaskets, bolts supplied with pump
39 (4) Flushing metal tube, flow meter, valves, pressure gauge of mechanical seal supplied with pump
40 (5) DCS monitor signal: Open/Close, Run/Error,1-way Comprehensive Alarm
41 (6) No use cuprum, zincum
42 (7) Other requirements see appendix <General requirement of process electrical and instrument>
43
44

DESED.BY: CHKED.BY: EXAMD.BY: TSL DWG. NO.:TSP-04-02-62-11-018-001


ACRE COKING & SHEET 1 of 1 Rev. 00
REFRACTORY ENGINEERING TECHNICAL DATA SHEET
Tar-ammonia Liquor Separating Unit
CONSULTING
CORPORATION(DALIAN), MCC PROJ.- NO. :
CENTRIFUGAL PUMP
ACRE-NO. PROJECT: TSK COBP-3,4
1 Use : Filter washing water pump No. of set : 2 sets Item-No.: 2P41411AB
2 Normal operation : 1 set Standby : 1 set
3 Standards :
4 Design data Meteorological and site condition
5 Medium ammonia water Flow rate 50 m3/h Altitude above sea level 60 m

Seismic condition:
6 Tar
Zone –III as per BIS: 1893
7 Corrosion by tar ammonia mix liquor Suction pressure 0.03 MPa(g) Atmosphere temperature 17.4~44℃
8 Operating temper at.(normal) 70℃ Atmospheric pressure average 100.63kPa
9 Operating temper at. (max.) 78℃ Pressure head (liquid) 42 m Relative humidity 45~85%
10 Density at. (normal) 998kg/m3 Efficiency estimated
11 Viscosity at. (normal) 0.406mPa.s rating at shaft estimated
12 Vapor press at.(normal) 0.039MPa(a) Mode of operation continue.
13 Solidification point ℃ NPSH required m
14
15
16 Construction Installation condition Shaft sealing
17 Type Centrifugal pump Location Outdoors single mechanical seal
18 Position of shaft Horizontal Hazard environment / Self-Flushing
19 Impeller type Close
20
21
22 Material Spare part(equipment supply) Other
23 Pump casing S30408 Mechanical seal
24 Impeller S30408
25
26
27 Drive Other
28 Drive E-motor Speed 1450 rpm
29 Voltage 415 V Phase 3
30 Frequency 50 Hz Rating estimated 15 kW
31 Ex. Protection / Type of protection IP55
32 Insulation grade F Heater No
33 Vary frequency
34
35
36 Remarks : (1) Standard for nozzles:ASME B16.5
37 (2) Base bolt for installation supplied with pump
38 (3) Inlet and outlet pipe flanges, gaskets, bolts supplied with pump
39 (4) Flushing metal tube, flow meter, valves, pressure gauge of mechanical seal supplied with pump
40 (5) DCS monitor signal: Open/Close, Run/Error,1-way Comprehensive Alarm
41 (6) No use cuprum, zincum
42 (7) Other requirements see appendix <General requirement of process electrical and instrument>
43
44

DESED.BY: CHKED.BY: EXAMD.BY: TSL DWG. NO.:TSP-04-02-62-11-018-001


ACRE COKING & SHEET 1 OF 1 Rev. 00
REFRACTORY ENGINEERING TECHNICAL DATA SHEET
Tar-ammonia Liquor Separating Unit
CONSULTING
CORPORATION(DALIAN), MCC PROJ.- NO. :
CENTRIFUGAL PUMP
ACRE-NO. PROJECT: TSK COBP-3,4
1 Use : Washing water pump No. of set: 2 sets Item-No.: 2P41412AB
2 Normal operation : 1 set Standby : 1 set
3 Standards :
4 Design data Meteorological and site condition
5 Medium tar ammonia mix liquor Flow rate 65 m3/h Altitude above sea level 60 m

Seismic condition:
6 Tar
Zone –III as per BIS: 1893
7 Corrosion by tar ammonia mix liquor Suction pressure 0.03 MPa(g) Atmosphere temperature 17.4~44℃
8 Operating temper at.(normal) 70℃ Atmospheric pressure average 100.63kPa
9 Operating temper at. (max.) 78℃ Pressure head (liquid) 33 m Relative humidity 45~85%
10 Density at. (normal) 1130kg/m3 Efficiency estimated
11 Viscosity at. (normal) 38.1mPa.s rating at shaft estimated
12 Vapor press. at. (normal) 0.039MPa(a) Mode of operation continue.
13 Solidification point ℃ NPSH required m
14
15
16 Construction Installation condition Shaft sealing
17 Type Centrifugal pump Location Outdoors single mechanical seal
18 Position of shaft Horizontal Hazard environment / Flushing with ammonia water (0.45 MPa)
19 Impeller type Close
20
21
22 Material Spare part(equipment supply) Other
23 Pump casing S30408 Mechanical seal
24 Impeller S30408
25
26
27 Drive Other
28 Drive E-motor Speed 1450 rpm
29 Voltage 415 V Phase 3
30 Frequency 50 Hz Rating estimated 15 kW
31 Ex. Protection / Type of protection IP55
32 Insulation grade F Heater No
33 Vary frequency
34
35
36 Remarks : (1) Standard for nozzles:ASME B16.5
37 (2) Base bolt for installation supplied with pump
38 (3) Inlet and outlet pipe flanges, gaskets, bolts supplied with pump
39 (4) Flushing metal tube, flow meter, valves, pressure gauge of mechanical seal supplied with pump
40 (5) DCS monitor signal: Open/Close, Run/Error,1-way Comprehensive Alarm
41 (6) No use cuprum, zincum
42 (7) Other requirements see appendix <General requirement of process electrical and instrument>
43
44

DESED.BY: CHKED.BY: EXAMD.BY: TSL DWG. NO.:TSP-04-02-62-11-018-001