PT
SP12-100(12V100AH)
                                                                Specification
                                                                        Nominal Voltage
                                                                                                     106AH (20hr, 1.80V/cell, 25 /77 )
                                                                                                     100AH (10hr, 1.80V/cell, 25 /77 )
                                                                        Nominal Capacity
                                                                                                     85AH (5hr, 1.75V/cell, 25 /77 )
     Features
                                                                                                     60AH (1hr, 1.60V/cell, 25 /77 )
                                                                                                     Width 172 ± 2mm
                                                                           Dimension
     * Maintenance-free operation
     * Stable quality and high reliability                                                           Total Height(with Terminal) 220 ± 2mm
     * Compact design                                                    Approx Weight               Approx 29.5Kg
     *                                                                      Terminal
     * ABS case, Flame Retardant V0 is alternative option               Container Material           ABS
                                                                     Max. Discharge Current          1000A (5S)
                                                                       Internal Resistance
     Application
                                                                                                     Discharge:-15-50     5-122
                                                                     Operating Temp.Range            Charge:0-40    (32-104 )
                                                                                                     Storage: -15-40    (5-104 )
     * Telecommunication system                                   Nominal Operating Temp.Range
     * Alarm and security system                                                                     14.4~14.8V (25 /77 ) Temp.Coefficient -30mV/
                                                                            Cycle Use
     * Backup power for testing and measuring instruments                                            Initial Charging Current Less than 30A
     * UPS                                                                                           13.5~13.8V (25 /77 ) Temp.Coefficient -20mV/
                                                                          Standby Use
     * Emergency lighting                                                                            No limit on Initial Charging Current
     * Fire alarm and security systems
                                                                      Capacity affected by
     * Auto control system
                                                                         Temperature
     * Electronic apparatus and equipment
     * Communication power supply
     * DC power supply                                                   Self Discharge              At 25   (77 ) and then a freshening charge is required.
                                                                                                     For higher temperatures the time interval will be shorter.
     Dimension
                   Unit: mm
                        φ20
                         M8
              6
                                                                              173±2
                                                 220±3
                                                212±3
                                                                                                 330±3
                                                                                                             PT. Solid Power Energi Indonesia
                                                                                                                  www.solidpower.co.id
                                                                  PT
Cycle Life With Depth Of Discharge (D.O.D.)   Charge Characteristics Curve For Standby Use
Storage Characteristics                       Effects Of Temperature On Float Life
Discharge Characteristics Curve               Temperature Effects With Capacity
                                                           PT. Solid Power Energi Indonesia
                                                                www.solidpower.co.id