Download as PDF, TXT or read online on Scribd
You are on page 1/ 129

2020

2020

L G AI R
SOLUTION

LG Electronics Distributed by
http://www.lg.com
http://partner.lge.com

Copyright © 2020 LG Electronics. All rights reserved.


022-101 164-169
OUTDOOR HOT WATER
UNITS SOLUTION
MULTI V 5 024 HYDRO KIT 166

MULTI V S 052

MULTI V M 070

MULTI V WATER IV 078


(HEAT PUMP / HEAT RECOVERY)

170-179 180-235
VENTILATION CONTROL
SOLUTIONS SOLUTIONS
ERV 172 INDIVIDUAL CONTROL 184
ERV WITH DX COIL 178 CENTRALIZED CONTROL 192

INTEGRATION DEVICE 204

102-163
236-257
INDOOR
ACCESSORIES
UNITS
MECHANICAL ACCESSORIES 238
WALL MOUNTED 104
INDEX

PIPING ACCESSORIES 246


CEILING MOUNTED CASSETTE 114

CEILING MOUNTED ROUND CASSETTE 132

CEILING CONCEALED DUCT 136

FRESH AIR INTAKE 148

CEILING & FLOOR CONVERTIBLE 150


CEILING SUSPENDED

CONSOLE & FLOOR STANDING 154

COMPATIBILITY 160

FEATURE FUNCTIONS 163

002 / 003
10 ADVANTAGES
OF MULTI V

5 SMART
CONTROLS 6 BUSINESS
SUPPORT
MUTI V responds to diverse building - Engineering Tools & Support
environments with LG ThinQ-based - LG Air Conditioning Academy
AI control and individual/central - European LG Energy Lab
integrated control solutions - European Air Conditioning
Distribution Center

1 ULTIMATE
EFFICIENCY 3 SUPERIOR
DURABILITY 4 DESIGN
FLEXIBILITY
Ultimate Energy Saving with LG’s exclusive “Ocean Black Fin” Flexible Installation with
Dual Sensing Control heat exchanger is designed
to perform even in corrosive
Environments.
Large Capacity Outdoor Unit.

MULTI V 5 enables easy type


change-over to suit the purpose
7 DIVERSE
PRODUCT
LINEUP
9
R32
10
BRAND
of any building
Hydrophilic film
MULTI V S allows versatile design LG offers a specialized product
APPLICATION RELIABILITY
Acryl + Epoxy +
Melamine resin with flexible piping locations lineup suited for various business
environments, perfectly responding New line-up applying the Global production sites facilitate
Humidity Temperature Aluminum fin
to the unique conditions no matter industry-first mini VRF with R32 world-class customer service.
the use case. refrigerant to MULTI V S

2
8 DIVERSE
Certified protection

INNOVATIVE INTEGRATED
TECHNOLOGIES SOLUTION
Ultimate Inverter Compressor Integrated solution optimized for
- MULTI V 5 various business environments,
Revolutionary Scroll R1 Compressor including hot water, AHU, BMS,
- MULTI V S R32, MULTI V M ※ Verification of corrosion resistance performance
- Declared by TUV Rheinland
and EMS
- Test Method B of ISO21207
- Test condition: Salt contaminated condition
+ s evere industrial/traffic
environment(NO2/SO2)

004 / 005
WHY LG MULTI V

MULTI V BRAND HISTORY INFRASTRUCTURE IN EUROPE

2017 ~

2013 · Dual Sensing Control


· Ultimate Inverter
Compressor
· Eurovent Certification
2010 · One Unified Platform
LG Air Conditioning Academy European Air Conditioning
· Active Refrigerant Heat pump & Heat
Distribution Center
Control recovery
· High Pressure Oil Return · Variable Heat Exchanger LG has set up 20 official air conditioning academies in Europe, LG’s European Air Conditioning Distribution Center is locat-
2008 · Ocean Black Fin
· Vapor Injection Circuit teaching much needed skills to thousands of current industry ed in Oosterhout, the Netherlands. Supplying and delivering
· Continuous Heating · Smart Load Control professionals including installers, consultants, designers, sales products all over Europe, this distribution hub has contributed
· Ø7.0 Wide louver staff and service technicians. The academy program is being to smooth and rapid delivery, direct shipping for smaller or-
2006 · Smart Oil Return
· LGDC Inverter · Vapor Injection used to share expertise ders and delivery tailored to air conditioners. The hub tries to
(Advanced)
and educate these HVAC experts by providing a cutting-edge manage inventory efficiency by taking advantage of LG EU’s
· Heat Recovery
technical experience with the newest and most advanced established inventory pool.
technologies and equipment. Moreover, as LG’s entire prod-
· Ø7.0 Corrugate
uct range is installed on site, professionals can be trained in
· Fuzzy Algorithm
a realistic way that offers them the chance to experience the
· AC Inverter
latest products first-hand.
· R410A

Since the time when LG launched Korea’s first residential air Multi V’s wide range of VRF solutions satisfies various building
conditioner in 1968, the company has worked to continuously types and sizes. Multi V S’s size discharge was designed Air Conditioning Academy
enhance its technological innovation and reliability. As a for small to mid-sized buildings while Multi V Water is a
result of sustained improvement, LG VRF launched the first water-cooled VRF solution with variable water flow control Europe Energy Lab
generation of MULTI V in 2006 and achieved significant technology.
development. With the best-in-class compressor technology European Distribution Center
and innovation applied to every part and control solution, In 2017, the ultimate VRF solution was introduced with Multi V 5.
Multi V has evolved to be on of the world’s most efficient and This generation has fully improved its technological potential
reliable VRF solutions. with the powerful and reliable yet economical Ultimate Inverter
Compressor, effective corrosion resistance with the Ocean
The first and second generations of Multi V boasted inverter Black Fin coating and enlarged fans. Dual Sensing Control
technology and non-ozone depleting technology, while Multi V III was offers the most pleasant indoor environment while minimizing
produced with cutting edge tech like oil return with HiPORTM unnecessary energy loss by sensing both temperature and
and double compression features with mid-pressure refrigerant humidity to efficiently manage cooling, heating and part load.
allowed by Vapor Injection. The innovative technologies of
Multi V’s fourth generation brought about product leadership Multi V 5 has been designed for the ultimate efficiency,
in efficiency. Its smart load control adjusts with the outdoor performance, flexibility, comfort and control, ensuring the most
temperature, while optimizing refrigeration management and pleasant indoor experience.
heat exchange for both cooling and heating.

006 / 007
WHY LG MULTI V

ENGINEERING TOOLS & SUPPORT


From planning to service & maintenance and then to de-construction, an architectural project goes through many stages from 01 Draft Energy Estimation
the beginning to the end of its lifecycle. Along those stages, various engineering tools are applied to solve the diverse issues
happening in each stage, with the most optimal solution possible. Given the usage of such tools, buildings are effectively LATS Energy
designed, built, supervised, and maintained throughout their lifecycle. LATS Energy is a program developed by LG to estimate energy consumption and
Dedicated to provide the best HVAC engineering support, LG Electronics Air Solution Business Unit offers several engineering analyze the life cycle cost of LG commercial air conditioning systems during a
tools and solutions focused on HVAC, during the overall lifecycle of a building, related to the three categories. Among them, the project's early stages.
LATS* Program series has been developed to offer the best tool for LG HVAC systems, providing our customers with a solution
that allows for faster, easier and more accurate model selection, draft energy estimations and more.

02 Building Energy Modeling


* LATS : LG Air-conditioner Technical Solution
eQuest, EnergyPro, Trace700 and More
These are certified commercial programs which assess the HVAC system efficiency
and building’s annual energy savings for building standards or certifications, like LEED.
LG HQ supports these programs for the project stages of Design Development and
Construction Design wherein the overall designing is finished.

03 Model Selection
I II III LATS HVAC
LATS HVAC is a model selection program that accurately and quickly selects the
Energy Estimation Model Selection Installation most suitable LG commercial air conditioning systems for each design. In addition
& Energy Modeling & Design Environment to model selection, faster estimation on refrigerant piping diameter and additional
Simulation refrigerant is possible, along with auto printing of reports.

04 Design
01 Planning LATS CAD
LATS CAD enables faster and more accurate 2D design of LG commercial air
LATS conditioning systems. It also enables modules for quotation and installation
ENERGY review that minimize inherent problems during installation and commissioning.
* AutoCAD program is required.

02 Schematic Design
LATS REVIT
LATS
LATS REVIT allows BIM users to have an attractive 3D design of LG commercial
HVAC air conditioning systems with embedded calculations for refrigerant and efficiency
features.
* AutoCAD Revit program is required.
03 Design Development
Energy
Modeling LATS CAD
- eQUEST Ⓡ LATS REVIT
- TRNSYS
05 Environment Simulation
CFD
04 Construction Design - FLUENT CFD Analysis
CFD Analysis is applied in areas of estimating: indoor airflow and temperature
distribution while operating VRF products, outdoor airflow distribution, and noise
level. By running a simulation before construction, engineers estimate possible issues
and find optimal solutions for malfunctions that could occur after construction.
05 Construction

06 Service & Maintenance


LGMV
06 Service & Maintenance LGMV LGMV offers real-time MULTI V cycle monitoring. During start-up, LGMV can
check for normal operation as well as troubleshoot any errors. Also it helps to
find causes of errors and solve the problem faster.

008 / 009
WHY LG MULTI V

BENEFITS OF LG MULTI V

Benefits for Benefits for


Building Owners Consultants
Efficient Management & Cost Reduction Versatile Solutions
- Fault Detection Diagnosis enables easy maintenance - Air-cooled, Water-cooled, Heating, and Air Handing
- Requires no extra manpower for regular Unit interlocking solutions
maintenance
- With diverse control systems, maintenance cost is
Professional Design Support
minimized
- LATS(LG Air-conditioner Technical Solution) for
Reliablility at Every Stage draft energy estimation, model selection, HVAC
-U
 ltimate Inverter Compressor developed and design and 3D designing
manufactured in Korea - CFD Analysis to ensure suitable solutions and
-C
 orrosion resistant Ocean Black Fin for harsh prevent malfunctions
conditions operation - Energy simulation offered to find the optimal
-S
 mart Oil management (Auto Oil Balancing and solution
Active Oil return) decreases compressor damage
Optimized Convenience with HVAC Design
Customized Comfort and Solution - Flexible and longer piping length facilitates
- Compatible option between Heat pump and Heat HVAC designing process
recovery system is possible - Meets any type of customer requirements of
diverse environment, design conditions, and
building applications

Benefits for Benefits for


Developers & Construction Companies End-users

Green Solutions Cost Saving Operation


- Optmized for LEED/BREEAM certification - High efficiency guaranteed throughout product
- Renewable energy solution provided through line-up
geothermal application - Up to 31% cost savings with Multi V's Smart Load
Control*
Maximizing Space Utilization
- L arge capacity in compact size enhances space
utilization Comfort Cooling & Heating
- Smart Load Control maximizes indoor comfort level
- Dual Sensing Control offers pleasant and
Smart Building Solutions comfortable cooling and heating environment
- Seamless integration with current Building - Duration time of Continuous Heating is 11%
Management Systems longer than previous model**
- Wi-fi control available for anytime, anywhere
access (via the 'LG ThinQ' mobile app) Convenient Functions
- Energy management and control according to - Low-noise operation provides a pleasant
usage and planning is possible with LG’s centralized environment
control solution

* Dual Smart Load Control ESEER based, below 50% humidity, model ARUM260LTE5
** LG internal test result

010 / 011
WHY LG MULTI V

APPLICATION SOLUTIONS

Office Residential
Supporting efficiency with flexibility Creating a comfortable home

High Rise Office Building Small to Medium sized Office Building Condominium & Apartments Single Family House & Villa

• MULTI V WATER IV • High Static Duct • Variable water flow • MULTI V S HR • 1/2 Way CST
• MULTI V 5 / S • 4 Way CST* • PDI** • MULTI V S • Therma V • ESS* & PV** Solar
• DX AHU • PDI** control kit • Hydro Kit • 3rd party controller RTU gateway

The MULTI V series revitalizes the workspace by providing fresh air at all times. LG's intelligent control solutions add comfort Remarkably compact size and high static pressure of MULTI V S enables optimal space solution, providing comfort to every
to any space. space through individual zone control and hot water solution.

Commercial Hospitality
Maximizing business, minimizing cost Meeting diverse needs

Shopping Mall Retail Quick Service Restaurant (QSR)

• MULTI V M • Convertible • MULTI V M • Hydro Kit


• MULTI V 5 • DX AHU • MULTI V 5 • DX AHU • Hydro Kit • Low Static Duct • Remote control • Refrigerant leak detector
• ERV • ERV • 4 Way CST

The highly efficient, energy saving MULTI V 5 and MULTI V M reduces operation costs, and provides comfort that suits any The diverse applications that can be applied to MULTI V 5 helps bring just the right solution to a sophisticated hotel business.
purpose and any space, helping to invest the extra space and expense to your business.

* CST : Cassette ** PDI : Power Distribution Indicator * ESS : Energy Storage System * PV : Photovoltaics

012 / 013
WHY LG MULTI V

DIVERSE INTEGRATED SOLUTION DIVERSE INTEGRATED SOLUTION


Hot Water Solution Refrigerant Leak Detection Solution Energy Management Solution Interlocking Solution
Water heating costs can be reduced with a heat pump, which provides Real-time refrigerant leak detection ensures a safe environment. When Since HVAC systems use a significant portion of any building’s total by Using ACU Module
higher efficiency than a boiler system. The Hydro Kit can be connected refrigerant concentration exceeds 6,000ppm for 5 seconds, the indoor amount of energy, the energy saving functions of a controller can make a
It is costly to introduce a BMS system to control multiple devices or
to Multi V 5, providing temperatures up to 80C. Energy savings can be unit will stop operation and alert users with a buzzer or light switch big difference. The energy navigation function enables you to set target
systems in a small building. With the ACU module, various IO contact
maximized with the combination of the Hydro Kit and the Multi V 5 (dry contact option). values for energy consumption over a certain period of time. In addition,
points (DI, DO, UI, AO) can be interlocked and integrated , while control
Heat Recovery system. to achieve that value, the administrator can set the energy saving logic
is possible from the LG central controller. This enables an efficient
in 7 steps and predict the expected usage relative to the target value.
ROOM management of lighting, pumps and other devices in the building in
Indoor Unit Active self-management enables energy savings through out the building.
Buzzer Alarm conjunction with the HVAC system.
Card Key
Multi V 5
Outdoor Unit Saving Engineering Cost
Cooling I/O Module
70% Pump Lighting Fan Sensor
Strengthen
Maintenance Efficiency
HR Unit Compressor Capacity IDU Operation IDU Operation
Ball Valve Control Ratio Control Level
ACS IO Module
(field supply)
Multi V 5
Outdoor Unit
Refrigerant Remote
Detector Controller
Target
AC Smart (ACP)
※ Regulation : EN378, BREEAM, ASHRAE Std. 15 & 34
Forecasting
Hydro Kit Heating Hot Water

Power Consumption Distribution Solution Interlocking Solution Using Dry Contact


Air Handling Unit (AHU) Solution In case of shared power consumption in a building, a solution to 3rd party thermostats can be used to control LG air conditioners in a
distribute the power consumption amount per tenant might be room by using a multi point dry contact. The dry contact enables basic
AHU is a suitable solution for cooling and heating in large space. necessary. Electricity charges can be billed to each tenant by using control of air conditioners as well as making it possible to report the
With an LG AHU Comm. Kit (for both return air / supply air control) output from the LG Power Distributor Indicator (PDI). An administrator status and any errors impacting the indoor unit.
connected to the DX coil of the AHU, LG VRF system can be applied to is able to check the power usage for each space and date as needed. If Integration Solution with BMS The Standard III remote control has a DO port. With this DO port, it
deliver conditioned air. the PDI is used in conjunction with an LG central controller, the results
There are many BMS protocols used for the control of buildings’ various is possible to interlock the indoor unit with 3rd party devices such as
can be exported to Excel.
Multi V 5 B Office systems such as HVAC, lighting, power and security. LG has a wide lighting, a fan, or a radiator, based on things like operation mode or
Outdoor Unit 20 kWh
WHM range of gateway products for different protocols such as BACnet, current temperature.
C Office
(Watt Meter)
Pulse Signal 30 kWh D Office Modbus, and LonWorks. In addition, LG gateways include Stand-alone The indoor unit can be interlocked with various types of input such as
A Office
20 kWh central control capability to act as a back-up controller of the BMS if
30 kWh card key-tag, door sensor, human detection sensor etc. so that the air
needed. conditioner is automatically operated. In addition, the dry contact
option settings enable operation of air conditioner to maintain proper
Small - Medium size building Medium - Large size building temperature when the occupant is absent. This solution makes sure
Power PDI
100 kWh that the room does not overheat or become too cold when unoccupied
IDU ~64 : ACP LonWorks so that energy cost can be saved.

Total Control of Any Device IDU 16~64 : Modbus RTU


IDU ~128 : AC Smart 5
(BACnet IP/Modbus TCP)
EEV Signal In order to manage multiple spaces and multiple buildings, the
administrators should be able to control systems from wherever they
Communication are. The LG central controller can be controlled from any web browser IDU ~256 : ACP 5
Kit Indoor Unit that supports HTML5. Now through the implementation of HTML5, (BACnet IP/Modbus TCP)
EEV Kit
the interface will look great and perform well on any device.

BMS Protocol
BMS System

Ref. pipe (Liquid)


Ref. pipe (Gas)
Communication

AHU

Management office Library Main administration building


PC Tablet Mobile

014 / 015
LINE-UP

OUTDOOR UNITS LINE-UP Unit : HP


● 380V, 3Ø ○ 220V, 1Ø

Features Appearance 4 5 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 .... 96

● ● ●

● ● ● ● ● ● ●
• Dual Sensing Control
• Large capacity ODU (Up to 26HP)
• Continuous Heating
• Ocean Black Fin heat exchanger ● ● ● ● ● ● ● ● ● ● ● ● ● ●
High Rise
• Heat pump or heat recovery function
Building
• Flexible installation with
heat recovery unit and large capacity
• For large space, high rise building and ● ● ● ● ● ● ● ● ● ● ● ●
individual control building

● ● ● ● ● ●

○ ○

• Space saving
• Flexible design applications ● ○● ○●
- Slim, light, and broad range (4 - 12 HP) Small-sized
- Large number of connectable indoor units
Building
(Up to 20 Units)
• For small / medium building
● ● ●


Heat Recovery

○ ○ ○
R32

• High flexibility of installation ●


• Quiet operation
Small-sized
•V
 arious indoor unit combinations & Building
long distance between modules

● ● ● ●

Heat Pump / Heat Recovery

•H
 igh efficiency system regardless external conditions ● ● ● ● ● ● ● ●
• Indoor installation
• Low noise operation (no fan)
•F
 or water-sourced system, high rise building and Large-sized
building with aesthetic requirements. ● ● ● ● ● ● Building
• Simultaneous cooling and heating
•M
 inimized energy cost by water sourced
heat recovery system
• For individual control building
● ● ● ● ● ●

016 / 017
LINE-UP

INDOOR UNITS LINE-UP INDOOR UNITS FEATURE OVERVIEW


Thermo Thermo Static Pressure 1 Point Auto
kW 1.5 2.2 2.8 3.6 4.5 5.6 6.2 7.1 8.2 9.0 10.6 12.3 14.1 15.8 22.4 28.0 Occupied /
Model Refrigerant On / Off On / Off 11 Step Control External Filter Sign Rerstart
Energy 2 Set Unoccupied Group Test Run Test Run Auto Wi-Fi
Information Leakage Range Range (Only for Ceiling Input (Remaining Function
Monitoring Point Scheduling Control (Cooling) (Heating) Addressing Ready
Type Btu/h 5k 7k 9k 12k 15k 18k 21k 24k 28k 30k 36k 42k 48k 54k 76k 96k Function
Monitoring Detection Setting Setting Concealed (On / Off Time) Disable /
(Cooling) (Heating) Duct Type) Control) Enable

Artcool Gallery ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

4 generation
th

Wall
Artcool Mirror ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Mounted
Unit

Standard ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

4 Way Cassette
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
(570 x 570)

4 Way Cassette
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
(840 x 840)

4 Way Cassette High Sensible


4th generation (840 x 840) ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Ceiling
Mounted
Cassette Round Ceiling Cassette ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

2 Way Cassette ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

1 Way Cassette ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

Mid /
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
High Statics
4 generation
th

Ceiling
Low Statics ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Concealed
Duct

High Sensible ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

4th generation
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Fresh Air Intake Units

4th generation
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Ceiling & Floor Convertible Unit

4th generation
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Ceiling Suspended Unit

4th generation
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Console

Floor Standing Unit


4th generation with Case ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Floor
Standing
Unit Floor Standing Unit
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
without Case

Low Temperature ● ● ● ● ● ● ● ● ● ● ● ● ● ●
4th generation
HYDRO KIT
High Temperature ● ● ● ● ● ● ● ● ● ● ● ● ●

4th generation with Humidifier ● ● ● ● ● ● ● ● ● ●


Energy
Recovery
Ventilator
with DX Coil without Humidifier ● ● ● ● ● ● ● ● ● ●

1) If 4th generation indoor units are connected to MULTI V WATER S, several funtions are not available.
2) If 4th generation indoor units are combined to 2nd generation indoor units, several funtions are not available.
More detailed information, refer to the "MULTI V Indoor units Compatibility Table"

018 / 019
LINE-UP

LG HVAC CONTROL LINE-UP


INDIVIDUAL CONTROL CENTRALIZED CONTROL CENTRALIZED CONTROL INTEGRATION DEVICE
Wired Remote Controller Wireless Remote Indoor Unit
Display Platform Gateway Facility Integrator Outdoor Unit AHU Kit
Standard Simple Controller Dry Contact Control Accessory
PDI IO Module
Standard III (White) NEW AC Ez ACP 5 ACP Lonworks (Power Distribution Indicator) Group Control Wire (Input / Output Module) Communication Kit

PREMTB100 PQRCVCL0QW PWLSSB21H (H/P) PQCSZ250S0 PACP5A000 PLNWKB000 Premium (8 port) Simple Dry Contact PZCWRCG3 For MULTI V 5 Return/Room Air control
(Indoor Unit ~32) (Indoor Unit ~256) (Indoor Unit ~64) PQNUD1S40 PDRYCB000 PVDSMN000 PAHCMR000
BACnet IP / Standard (2 port)
Modbus TCP PPWRDB000
Wi-Fi Controller
ACS IO Module Variable Water Flow
Standard III (Black) LG Wi-Fi Modem AC Ez Touch AC Manager 5 Modbus RTU Gateway (Input / Output Module) Remote Temperature Sensor Control kit

PEXPMB000 Dry Contact for Thermostat PQRSTA0 For MULTI V WATER IV Discharge/Supply Air control
PREMTBB10 PQRCVCL0Q For Indoor Unit PACEZA000 PACM5A000 PMBUSB00A
PDRYCB300 PWFCKN000 PAHCMS000
PWFMDD200 (Indoor Unit ~64) (Indoor Unit ~8,192)
Low Profile Remote
Chiller Option Kit Temperature Button Sensor Low Ambient Kit Controller Module
Standard II (White) AC Smart 5 PI-485

PCHLLN000 Dry contact for Thermostat ZRTBS01 For MULTI V IV, 5 Main module
(For using universal input) PRVC2 NEWPAHCMM000
NEW PDRYCB320
PREMTB001 PQRCHCA0QW PACS5A000 For Indoor Unit (ERV)
(Simple for Hotel) (Indoor Unit ~128) PHNFP14A0 ACU IO Module
BACnet IP /
Modbus TCP UIO Zone Controller Cool / Heat Selector
Standard II (Black)

PEXPMB300 2 Points Dry Contact (For Setback) 4 Zones by PRDSBM Communication module
PDRYCB400 thermostat ABZCA NEW PAHCMC000

PREMTBB01 PQRCHCA0Q
(Simple for Hotel) UO Water Communication Module Control kit

Premium

PEXPMB200 For Modbus NEW PAHCMW000 NEW PAHCNM000


PDRYCB500 (Max 3 Outdoor Units)

UI EEV Kit
PREMTA000 (Electronic Expansion Valve)
PREMTA000A
PREMTA000B

PEXPMB100 PRLK048A0 (~ 28 kW)


PRLK096A0 (~ 56 kW)

NEW PRLK396A0
(~ 112 kW)

NEW PRLK594A0
(~ 168kW)

020 / 021
OUTDOOR
UNITS

MULTI V 5 / MULTI V S / MULTI V M

MULTI V WATER IV (HEAT PUMP / HEAT RECOVERY)

022 / 023
OUTDOOR
UNITS
1,000m 225m
TOTAL PIPING LENGTH Longest Piping Length

- Air cooled VRF Heat Pump & Heat Recovery

between ODU ~ IDU

MULTI V 5
Height Difference
- 22.4kW ~ 268.8kW (Cooling capacity based)
- 3Φ, 380 ~ 415V, 50Hz

110m
- Top discharge outdoor unit
- Ability to function as Heat Pump or Heat Recovery

1,000M
TOTAL PIPING LENGTH

between IDU ~ IDU


Height Difference
40m
How does it work?
Dual Sensing

Energy savings

Partial Defrost

Reliability

Designed Interchangeable between


heat pump and heat recovery
For
The Ultimate Low noise

Type
Changeover

Advanced performance

024 / 025
OUTDOOR UNIT _ MULTI V 5 _ KEY FEATURES

INNOVATIVE TECHNOLOGIES INNOVATIVE TECHNOLOGIES

OUTDOOR
UNITS
Dual Sensing Smart Load Control (SLC) Energy Savings with Dual Sensing Control Comfort Cooling Intelligent Defrost
Enhanced energy saving & increased indoor comfort (Temperature & Humidity) Increased indoor comfort & enhanced operating efficiency Increased heating run-hours
Cooling loads vary according to both temperature and humidity. Case study First reference use Indoor Unit (IDU) is operating in a season when MULTI V has provided an intelligent defrost algorithm and settings
With Dual Sensing SLC, work exherted to meet the load depends its load is less than the design load, the comfort cooling algorithm based on current outdoor ambient temperature. With the addition

MULTI V 5
Weather characteristics of Warsaw, Poland
on both temperature and humidity. As a result, less capacity will be controls the indoor unit’s coil superheat, thus raising the discharged of the outdoor air humidity sensor, MULTI V 5 Intelligent Defrost just
The portion of cooling operation hours at low humidity condition (below
required in lower humidity conditions. air temperature as the space temperature is approaching set point. got smarter.
50% RH) is big. The cooling load of this condition is less than the load at
MULTI V 5’s comfort control algorithm monitors the outdoor air MULTI V 5 computes the current ambient air dew point temperature
It influences the VRF system main processor’s decision on where to standard (50 ~ 70% RH) or high (over 70% RH) humidity condition even in
temperature and humidity conditions. When changing weather - the temperature at which frost will form on the outdoor unit coil in
set the system’s target high or low system pressure values. the same outdoor air temperature. MULTI V 5 raises the evaporating Temp.
up at low load (low humidity) condition to enable energy saving and prevent conditions are deteriorating and there is a high potential the indoor during winter operation. MULTI V 5 makes continuous adjustments to
over-cooling which can happen when the system is controlled only by using unit’s load will remain stable or may increase, comfort cooling delays the refrigeration cycle's operating parameters to keep the outdoor coil
Smart Load Control responds to: outdoor air Temp. or abandons raising the target superheat as the room temperature surface temperature above actual dew point which can be calculated
1) Outdoor ambient dry bulb temperature approaches set-point. When changing weather conditions are
Warsaw weather in Summer by using dry bulb Temp. and relative humidity. When the refrigeration
2) Outdoor ambient relative humidity (when enabled) favorable to raising target superheat, target superheat is moderated. cycle's operating parameters can be adjusted no further without
90%
Cooling Indoor Units - adjusts target low pressure sacrificing heating comfort, further adjustment is stopped and frost is
80% High Humidity
Raises the target low pressure value as cooling load falls and/or ambient temperature falls.
Lowers the target low pressure value as cooling load rises and/or ambient temperature rises.
70% ~ 100% What are the benefits? allowed to build on the the coil, therefore activating defrost.

Relative Humidity
70%
Heating Indoor Units - adjusts target high pressure Mid Humidity Dual Increased indoor comfort
60% SLC Sensing
Lowers the target high pressure as heating load falls and/or ambient temperature rises. 50% ~ 70%
SLC If comfort cooling is turned off, and the temperature of the leaving air is not What are the benefits?
Raises the target high pressure as heating load rises and/or ambient temperature falls. 50%
raised, when the fan speed is reduced to low speed, there is a potential that
Low Humidity The Intelligent Defrost algorithm increases the VRF system’s heating run-hours
40% 0% ~ 50% occupants located directly under a cassette IDU or supply air registers could
What are the benefits? feel cold air falling on them resulting in a lower overall comfort experience.
and reduces the number of defrost cycles required to maintain optimum
30% heating performance irrelevant of the mode and method of defrost selected.
Enhanced energy savings With comfort cooling turned on, the discharged air temperature is controlled.
20%
When the IDU controller reduces the fan speed, the potential for cold air falling
- Cooling Mode 23°C 25°C 27°C 29°C 31°C 33°C 35°C
on occupants located under the cassette IDU or supply air registers is reduced.
By raising the target low pressure during off-peak cooling operation, the Source : Outdoor Air Temperature
https://energyplus.net/weather
compressor lift is reduced. This slows compressor’s speed which leads to a
Time Portion of Relative Humidity in Summer
Enhanced operating efficiency
decrease in compressor’s power consumption.
(Warsaw, Poland) Raising superheat reduces refrigerant volume flowing through the coil. As
- Heating Mode
RH (%) Portion flow decreases, demand on the compressor decreases and the compressor Conventional
By lowering the target high pressure during off-peak heating operation, the
speed will be reduced, thus saving energy. Defrost
compressor lift is reduced. This slows compressor’s speed which leads to a 70% ~ 100% 8%
decrease in compressor’s power consumption. 50% ~ 70% 45%
Previous Model Frost
0% ~ 50% 47% accumulation begins
Increased indoor comfort Coil
Surface (°C)
Smart Load Control uses one (or two) sensors to measure changing outdoor
weather conditions and prepares the VRF system for operation under Comfort &
the revised weather conditions before changing conditions impact indoor
Energy Consumption in Cooling Season Repeated on & off Continuous Cooling
When we compared the energy consumption between SLC (Outdoor air Dew Frost accumulation
comfort. Point (°C)
Temp. sensing only) and Dual sensing SLC (Outdoor air Temp. and humidity
Cooling load according to Cooling load according to
temperature change humidity change sensing), Dual sensing SLC control can save 6% more energy compared to
SLC. So dual sensing control is more efficient than SLC.
Cooling Load

Cooling Load

Cooling Mode Fan Mode Cooling Mode

EER * Indoor unit set up available with Standard III Remote Controller
MULTI V 5 SLC
MULTI V 5 Dual Sensing SLC 9.4 9.4
9.2
9.0 Preventing cold draft & repeated turn On / Offs
8.1 8.6
25°C 30°C 35°C Temperature 40% 60% 80% Relative 7.9
Humidity Improved Indoor Comfort
Latent heat load Sensible heat load 6.9 6.9
* constant indoor temp. condition 6.0
Indoor temp.
Cooling Load
Previous Cooling Capacity LG Intelligent Defrost /
For low temperature, Adjusting capacity Smart Heating
lower load and
to meet load Frost
Actually 31°C ~ 29 ~ 31°C 27 ~ 29°C 25 ~ 27°C 23 ~ 25°C Not cool accumulation begins
capacity are required External Load zone Coil
Required
Cooling
Outdoor Air Temperature Surface (°C)
Internal Load
Capacity
* This energy simulation was performed in LG internally based on 16HP model.
Temperature & Humidity
Evaporation Temperature
Low Humidity
Power Consumption in Cooling Season
Dew
SLC
Yearly Power Input (kWh) - ODU Point (°C)
Lower load and Comfort
OAT MV4 (Fixed) MV5 SLC MV5 Dual SLC zone Set
capacity need High Humidity Additional Time
temperature
higher evaporation 31 ~ 17 15 13 Spent Heating
Outdoor
temperature Standard Temperature (°C) 29 ~ 31 91 73 62
(Non SLC)
Low Temperature High Temperature 27 ~ 29 183 136 124

Efficiency 25 ~ 27 243 170 165


Too cool
Low Humidity
23 ~ 25 155 110 109 zone Increased heating operation time per day : Up to 17%
SLC
Total 690 (137%) 503 (100%) 474 (94%)
• LG Internal Test result,
Higher evaporation • Test condition (MULTI V 5 vs MULTI V IV, 22HP)
High Humidity
temperature results 6% more energy saving
in higher efficiency
Standard compared to SLC Previous Model Time - Outdoor : 2/1℃ , Indoor : 20/15℃
(Non SLC) Outdoor
Temperature (°C)
- Humidity : 83%, Dew Point : -0.5℃
Low Temperature High Temperature

026 / 027
OUTDOOR UNIT _ MULTI V 5 _ KEY FEATURES

INNOVATIVE TECHNOLOGIES INNOVATIVE TECHNOLOGIES

OUTDOOR
UNITS
Variable Path Heat Exchanger Active Refrigerant Control HiPORTM Sub-cooling & Vapor Injection
Optimized system efficiency & continuous heating Stable operation & sustaining most efficient operation Advanced compressor reliablity & efficiency Increased heating performance
MULTI V 5 outdoor units (ODU) are manufactured with horizontally The accumulator in the outdoor unit has a storage tank mounted HiPOR™ is an LG trademark that stands for High Pressure Oil Return. MULTI V 5 is equipped with advanced sub-cooler and vapor injection
split ODU coil consisting of two independent circuit sections. Each inside known as the receiver tank. The receiver tank is equipped It consists of an oil separator, oil drain line between the separator and the control system. The sub-cooler algorithm sub-cools liquid refrigerant

MULTI V 5
half of the coil is independently controlled. with inlet and outlet valves that are electronically opened and compressor. HiPOR™ technology enables oil to return directly into the just enough so that it can travel to the farthest IDU in the system
This split coil feature makes it possible for MULTI V 5 to provide closed. Refrigerant is being passed between the accumulator compressor, instead of returning through the refrigerant suction pipe. operating in cooling mode without changing state. During low
continuous heating during defrost. The split coil and valve and the receiver tank on a continuous basis. MULTI V 5 active This prevents energy waste when oil flows between the separator ambient operation down to -25°C (heating mode), the sub-cooler
arrangement also makes it possible for the MULTI V 5 to change refrigerant control algorithm goal is to minimize the amount of and the compressor. Because the operating pressure in the chamber provides medium temperature refrigerant gas to the compressor’s
the flow path of refrigerant through one of the two coils only, or refrigerant in circulation. The lower the volume in circulation the containing the oil sump of the compressor and the pressure in the oil vapor injection system. When injected into the compression
through both coils in either a series or parallel arrangement. Based lower the cost to move it around the system and the higher the separator are nearly equal, there is no loss in compressor efficiency. chamber, system mass flow increases which stabilizes the system’s
on system pressures, ambient temperature conditions, and mode of stability of the refrigeration cycle. It accomplishes this by constantly suction pressure. In all cases the vapor injection increases the
monitoring the system operating pressures and temperatures and What are the benefits? compressors cycle efficiency and reduces operating cost.
operation, the system controller may modify the selected path at
a variety of other vital control metrics of the refrigeration cycle. Maximizes reliability and efficiency of the compressor
any time.
When the cycle is out of balance, an adjustment in the amount of Non HiPOR™ HiPOR™ What are the benefits?
circulating refrigerant occurs. Compressor
1 Refrigerant Provides stable refrigeration cycle operation over a wide range of outdoor
What are the benefits? 3 ambient operating conditions.
4
Optimizes system efficiency regardless of operating modes as ambient weather Increases compressor efficiency when compared to systems without vapor
conditions change. What are the benefits? Efficiency Increase
Up to 33%
injection technology.
Customizes the used area of the outdoor unit’s heat exchange surface.
Widens the ambient temperature range at which stable operation occurs. 2

Oil Technology Mechanism


Low ambient cooling and / or light building load Sustains most efficient system operation regardless of outdoor weather 5

conditions, operating mode, or building load.


• Half active High-pressure
Non HiPOR™ HiPOR™
• Lower idle Low pressure High pressure Oil Low pressure High pressure Oil Low-pressure
Cooling Heating Part Load refrigerant Comprressor refrigerant Separator refrigerant Comprressor refrigerant Separator
1 2 3 4 1 2 3 4

Amount of refrigerant
Full load cooling in receiver
• Upper & lower active 5 Energy loss in suction gas No energy loss in suction gas 5

• Series circuited • LG Internal Test result,


• High velocity refrigerant flow • Test condition - 15Hz Rating Condition : TC = 37.9C˚, Te : 7.2℃

Heating - all conditions Smart Oil Management Mid-pressure


(Vapor injection port)
• Upper & lower active Energy saving, enhanced heating & increased compressor reliability
• Parallel circuited
• Low velocity refrigerant flow MULTI V 5 performs oil return when needed under normal operating
IDU (heating)
conditions. An oil level sensor is provided in every LG VRF compressor.
If the sensor indicates the compressor oil level is low, the main system
Efficiency
processor is notified that an oil return cycle is necessary. Oil balancing
EEV
Heating cycle occurs every hour and does not hinder system performance.
It balances the oil level deposit between both compressors in multi- High temp
discharge
compressor frames. Older VRF technology protects compressors from
Cooling Non-receiver tank
oil loss based on timed oil return logic because there was no way to
Fixed refrigerant amount Control optimized Refrigerant amount
Maximized efficiency know if the oil level in any one compressor was low. LG’s unique oil level MID-stage Injection
SC
Series Half Active Parallel measuring sensor actively monitors the oil level in each compressor. HEX
Low temp
Efficiency
Continuous Heating
What are the benefits? suction

Fixed refrigerant type Energy savings : f ewer oil return cycles eliminate unnecessary energy
Heating performance
consumption.
Increases system heating run-time during winter operation.
Heating ODU Coil
efficiency 3% Increases compressor reliability.

Part load Heating Performance Smart Oil Return


efficiency 10%
On Heating supply On Performance Comparison
Heating performance
Heating Heating Heating

Oil Oil
Non heating Non heating Non-Vapor Injection
Oil
Time
27%
Timed oil return logic (Non-oil Sensor) Oil Level Sensor
Effect of partial defrost
Increased heating operation time per day Auto Oil Balancing Up to
: Up to 12% -25℃
• LG Internal Test result,
Cooling
efficiency • Test condition
- without oil level sensor : -25 -20 -15 -10 -5 0 7 11 15
Time Active Refrigerant Control
Non-Partial defrost Refrigerant quantity (kg) every 8 hour oil recovery operation Oil Outdoor temp.(°C)
- with oil level sensor : * Improved heating performance by 27%
non oil recovery operation * Comparison tested on 10HP model
Oil Level Sensor

028 / 029
OUTDOOR UNIT _ MULTI V 5 _ KEY FEATURES

INNOVATIVE TECHNOLOGIES DESIGN FLEXIBILITY

OUTDOOR
UNITS
Corrosion Resistance Black Fin Biomimetic Fan One Unified Model Flexible Installation with
Improved durability Maximized performance Heat pump / Heat recovery with one platform Large Capacity Outdoor Units
The black coating with enhanced epoxy resin is applied on the heat The fans in Multi V 5's outdoor unit have been upgraded to feature a LG MULTI V 5 satisfies users’ various needs with just one platform. More flexible design potential & Space saving
exchanger for strong protection from various corrosive external moire pattern similar to that of a clam shell's exterior that help with Heat Pump System works for the sites where either cooling or heating

MULTI V 5
Large capacity outdoor units of MULTI V 5 minimize installation
conditions such as salt contamination and air pollution. Moreover, noise reduction. At the same time, unlike the fans installed in previous operation is needed, while Heat Recovery System fits perfectly to the
space that spares valuable floor space and significantly decreases
the hydrophilic film keeps water from accumulating on the heat products that generate separation of flow due to absence of tubercles, sites wherein both the cooling and heating operations are simultaneously
total installed weight. This gives users more flexible design potential
exchanger’s fin, minimizing moisture buildup and eventually making the bumpy back design inspired by the bumps on the humpback needed or locations installed with Hot Water Solution to provide hot
and better use of the saved space.
it even more corrosion resistant. whale’s flipper is applied as the tubercles on the back side of the fans, water and heating via radiators.
LG Corrosion Resistance solution passed ISO 21207 accelerated increasing wind power by reducing flacking. In addition to the biomimetic 12.25m2
corrosion test conducted by an independent test organization technology-based fans, extended shroud of MULTI V 5 allows more high
and the result has been certified by prestigious global certification static pressure and helps fans to blow higher air volume for efficient
organization, TUV. operation. With wider air guide, discharged air current is stabilized and What are the benefits?
Previous Model
noise level is reduced. MULTI V 5 allows the building previously installed with Heat Pump system to
23%
What are the benefits? switch to the Heat Recovery system (by adding HR boxes and a third pipe) 9.42m2 Reduction
for changing purpose of the building or remodeling reasons via simple piping
This improvement in durability prolongs the product’s lifespan and lowers both What are the benefits?
construction.
the operational and maintenance costs. Based on the biomimetic technology, the fans of MULTI V 5 increased air
flow rate by 10% in comparison to previous model and reduced its power
Heat Pump System
consumption up to 20% when compared with the fan blade design on
MULTI V IV. This eventually results in maximized performance with large capacity. 23% 15%
Reduction Reduction

12.25m2 9.42m2 3,640kg 3,100kg

Previous Model Previous Model

※ Verification of corrosion resistance performance Foot print area Product weight


- Declared by TUV Rheinland
Humpback * Comparison basis : 1 Rows of outdoor units 728kW (72.8kW x 10sets) installation case
- Test Method B of ISO21207
Whale Desigan
- Test condition: Salt contaminated condition
+ s evere industrial/traffic
environment(NO2/SO2)
Clam Shell
Pattern
Slave 1 Master
Outdoor unit Outdoor unit
Wider Operation Range
2 pipes Able to operate at extreme conditions
Hydrophilic film (Water flow)
THe Hydrophilic coating minimizes moisture Liquid Pipe
With improved inverter cooling technology, sub-cooling and vapor
buildup on the fin. Gas Pipe injection, MULTI V 5 offers an extended range of heating and cooling
Acryl + Epoxy + Melamine resin operations. It can perform normal heating operations at temperatures
(Corrosion resistant) Indoor unit
as low as -25°C. Cooling operations function at temperatures as low as
The Black coating provides strong protection

Changeover
from corrosion.
-15°C or as high as 48°C making it an adequate solution for specialized

Type
Aluminum fin areas like technical rooms. Moreover, MULTI V 5’s cycle technology
with enhanced durability enables optimal cooling performance at high
temperature that increases up to 48°C.
SST (Salt Spray Test)
Heat Recovery System Outdoor air temp. (°C WB)
Test Process Test Result
(5% Area of defects compared to initial)
18°C
15°C
1,950 hr

Process
repeated 1,000 hr
Fog1) 95%
(35°C, 24hr)

Test process is conducted according to ISO 9227. Gold Fin Black Fin
1) Salty water concentration : NaCl aqueous solution (5%) 100% copper material to -20°C
Air flow rate Power consumption
prevent corrosion & refrigerant -25°C
leakage m3/min W 10°C 15°C 20°C 27°C

Heating Indoor air temp.(°C DB)


CCT (Cyclic Corrosion Test) Heat Recovery Unit

Test Process Test Result


(5% Area of defects compared to initial) 320 1,500 Outdoor air temp. (°C DB)
20%
1,300 hr
10% Slave 1 Master 48°C
290 Outdoor unit Outdoor unit
3 pipes 43°C
500 hr
Fog1) Wet2) 1,200
(35°C, 2hr)
Dry
(70°C, 2hr) (50°C, 2hr)
160%
Previous Model

Gold Fin Black Fin


Process
repeated 100% copper material to Indoor unit -10°C
prevent corrosion & refrigerant
Test process is conducted according to ISO 14933. leakage Liquid Pipe -15°C
1) Salty water concentration : NaCl aqueous solution (5%) High Pressure Gas Pipe 10°C 14°C 25°C 27°C
※ Dry condition changed : 60°C, 4hr → 70°C, 2hr Previous Model Previous Fan Design
Low Pressure Gas Pipe Cooling Indoor air temp.(°C WB)
2) Deionized water
* Comparison based on 20HP model * Comparison based on air volume of 290m3/min HR unit

030 / 031
OUTDOOR UNIT _ MULTI V 5 _ KEY FEATURES OUTDOOR UNIT _ MULTI V 5 _ TECHNICAL DATA

USER-FRIENDLY CONTROL Nomenclature Multi


MultiVV
55

OUTDOOR
Outdoor
Outdoor
Units
Units
Cooling / Heating Operation

UNITS
ARU M 100 L T E 5 9.9.Operation
OperationLimits
Limits
Low-Noise Operation Simple Test Run via LGMV Serial number
Cooling
Cooling
Cooling / Heating
/ Heating
Operation
Operation Heating
For noise sensitive environment Increased overall efficiency in installation
E: High Efficiency 50°C 20°C
48°C
Unlike the previous model which enables Low-Noise Operation To make sure that the product functions properly, conducting a test run Air Discharge Type 45°C
18°C
T : Top Discharge 15°C
only during night after judgment time, the Low-Noise Operation of is recommended. For previous product, professional engineer who is well-

Outdoor Temperature (°C WB)

MULTI V 5
Outdoor Temperature (°C DB)
40°C
MULTI V 5 can function regardless of the time at the noise sensitive aware of more than 40 different functional settings and more than 200 Electrical Ratings
10°C

Range for warming up operation


Range for continuous operation

Range for continuous operation


L : 3Ø, 380 ~ 415 V, 50Hz 35°C

Range for pull down operation


areas. When used, the speed of the outdoor unit fans is restricted error codes had to check main parts in order to make sure that the test
Total Cooling capacity in Horse Power(HP) unit 30°C 5°C
during normal operation. run had succeeded. With Mobile LGMV of MULTI V 5, fast and accurate EX) 8HP → ‘080’, 10HP → ‘100’
Multi V 5
25°C
auto test run can be executed and the professional installer running the Outdoor Units 0°C
Combination of Inverter Type and Cooling Only, 20°C
Previous Model test can receive test results via email, which shortens installation hours Heat Pump or Heat Recovery
and increases overall efficiency in installation processes. 10. Sound Levels M : Inverter, Heat Pump and Heat Recovery 15°C -5°C

MULTI V System with Indoor Unit using R410A 10°C


ARU : Global line-up -10°C
Previous 10.1 Sound Pressure Level 5°C

0°C -15°C
Position of Sound Pressure Level Measuring -5°C
Load Note -20°C
-10°C
• Data is valid at free field condition -25°C
• Data is valid at nominal
-15°C
operating condition
10°C 14°C 15°C 20°C 25°C 27°C 30°C 10°C 15°C 20°C 25°C27°C 30°C
Sound level Off • Sound level will vary depending on a range of
Indoor Temperature (°C WB) Indoor Temperature (°C DB)
factors such as the construction(acoustic
1m Note
Note
(Judgment time) Low-noise operation time absorption1.coefficient)
1.
These
These
figures
figures
ofassume
assume
particular
thethe
following
room
following
inconditions:
operating
operating conditions:
which the equipment
Note
Equivalent
Equivalent is
piping installed
piping
length:7.5m
length:7.5m
1m 1. These figures assume the following operating conditions:
• Sound level can
Level be increased
Level
difference:0m
difference:0m
Equivalent piping length in :static
7.5m
On pressure mode
2. 2.
Rangeorofused
Range
Level
pull
of pull
downairoperation:
down
difference : guide.
operation:
0m
If the
If the
relative
relative
humidity
humidity
is too
is too
high,
high,
cooling
cooling
capacity
capacity
cancan
be be
decreased
decreased
by by
thethe
sensible
sensible
heat
heat
reduction.
reduction.
6:00 12:00 13:00 18:00 21:00 0:00 6:00
• Data is valid at free field condition 2. Range of pull down operation :
If the relative humidity is too high, cooling capacity can be decreased by the sensible heat
Highest Start End • Data is valid at nominal operating condition reduction. Unit:dB(A)
outdoor temp. • Sound level will vary depending on a range of factors such as the 3. Warming up operation means that the outdoor unit operates to reach the range
construction Mo(acoustic
del Coolingroom in
absorption coefficient) of particular H e a t i n g
of continuous operating, however it may not operate continuously due to safety or
A R U M 0 8 0 LT E 5
which the equipment is installed 58.0 59.0
protection logic.

• SoundAlevel
RUMcan 100be LTincreased
E5 in static pressure mode58 or.0used air guide. 59.0
ARUM120LTE5 59.0 Multi 60.0
Multi V 5V 5 Outdoor
Outdoor Units
Units
ARUM140LTE5 60.0 61.0
Outdoor Unit Function 9. Operation
Simultaneous
9. Operation6Limits Limits
Cooling / Heating Operation
ARUM160LTE5 60.5 1.5
ARUM180LTE5
Category Functions 61.0 MULTI V 5 Simultaneous
Cooling
Simultaneous 6Cooling
2.0 / Heating
Cooling / Heating Operation
Operation Heating
ARUM200LTVariable E5 Path of Outdoor Unit HEX 62.0 ○ 64.5
HiPORTM (High Pressure Oil Return) ○
Load
ARUM220LTE5
Key Refrigerant 64.5 30°C 65.5 20°C
Humidity Sensor ○
Components
ARUM240LTCorrosionE5 65.0 ○ 67.0
Resistance Black Fin 25°C 16°C 675675
ARUM260LTOil E5Sensor 65.0 ○ 67.0

Outdoor Temperature (°C WB)


Outdoor Temperature (°C DB)
15°C
Sound level Scheduled setting available ARUM221LTDual E5 Sensing 61.5 ○ 20°C 62.5

Range for continuous operation

Range for pull down operation


Low Noise Operation ○
ARUM241LTE5 62.0 63.0

Range for warming up operation

Range for continuous operation


Hgih Static Mode of Outdoor Unit Fan ○ 15°C
ARUM261LTPartial E5 Defrosting 62.5 ○ 63.5 10°C

Low-noise Low-noise
ARUM280LTAuto E5 Dust Removal of Outdoor Unit 62.8 ○ 10°C 63.8
operation operation Wi–Fi MV Module
ARUM300LT(Fan
Useful Function E5 reverse rotation) 63.1 64.1 5°C
On Off On Indoor Cooling Comfort Mode Based 5°C
ARUM320LTOutdoor E5 Temperature 63.8 ○ 65.8
6:00 12:00 18:00 6:00 ARUM340LTSmart E5 Load Control (SLC) 65.6 0°C 66.6
(Changing indoor discharge air ○ 0°C
Start End Start End ARUM360LTtemperature
E5 according to load) 66.0 67.8
-5°C
ARUM380LTOutdoor E5 Unit Control Refer to Humidity 66.2 ○ 68.0
Indoor setting available ARUM400LTDefrost E5 / Deicing 66.3 ○ 68.1 -5°C
-10°C
High Pressure Switch ○
ARUM420LTE5 66.5 68.2
Phase Protection ○ -15°C
ARUM440LTRestart
Reliability E5 Delay (3-minutes) 66.8 ○ 68.9 20°C
10°C 14°C 15°C 25°C 27°C 30°C -10°C
ARUM460LTSelf E5 Diagnosis 67.8 ○ 69.3 10°C 15°C 20°C 25°C27°C 30°C

ARUM480LTSoft E5 Start 68.0 ○ 70.0


Indoor Temperature (°C WB) Indoor Temperature (°C DB)
Note
ARUM500LTTest E5 Run Function 67.0 ○ Note 68.6the following operating conditions:
AC Ez (Simple Controller) PQCSZ250S0 1. 1. These
These figures
figures assume
assume the following operating conditions:
ARUM520LTAC E5Ez Touch 67.PACEZA000
1 Note
Equivalent
Equivalent piping
piping 6length:7.5m
8.7
length:7.5m
ARUM540LTAC E5Smart IV 67.PACS4B000
2 Level difference:0m 68.8 the following operating conditions:
1. These
Level figures
difference:0massume
Cycle Monitoring Diagnosis Installation Smart Management 2. 2.
Range
Equivalent
Range of pull
of pull
piping
down
down
length : 7.5m
operation:
operation:
Central A RUM560LTAC
Controller E5Smart 5 67.4PACS5A000 IfLevel
If the the difference
relative
relative humidity69 is .too
: 0m
humidity 5is too high,
high, cooling
cooling capacity
capacity cancan
be be decreased
decreased by the
by the sensible
sensible heatheat reduction.
reduction.
2. Range of pull down operation :
ARUM580LTACP E5 (Advanced Control Platform) IV 68.3 PACP4B000
69.8 is too high, cooling capacity can be decreased by the sensible heat
If the relative humidity
LGMV ACP (Advanced Control Platform) 5 PACP5A000
ARUM600LTAC E5Manager 5 68.PACM5A000
5 reduction. 70.4
ARUM620LTACP
BNU (Building E5 Lonworks 68.PLNWKB000
6 70.5
Network AUnit)
RUM640LTACP E5 BACnet 68.7PQNFB17C0 70.6
ARUM660LTRefrigerant
Installation E5 Charging Kit 68.8 PRAC1 70.6
Variable Water Flow Valve Control Kit -
ARUM680LTStandard E5 69.PPWRDB000
0 71.1
PDI (Power
ARU
Distribution M700LTPremium
Indicator) E5 69.PQNUD1S40
6 71.3
ARUSelector
Cool / Heat M720LTE5 69.8 PRDSBM 71.8
Low Ambient
ARUM Kit740LTE5 69.1 PRVC2 70.9
IO Module (ODU Dry Contact) PVDSMN000
ARUM760LTLGMV E5 69.2 PRCTIL0 70.9
Cycle Monitoring
Device Mobile LGMV PLGMVW100
677
※ ○ : Applied, - : Not Applied 676676

032 / 033
OUTDOOR UNIT _ MULTI V 5 _ TECHNICAL DATA

ARUM080LTE5 / ARUM100LTE5 / ARUM120LTE5

ARUM080LTE5
ARUM080LTE5 / ARUM100LTE5 / ARUM120LTE5 ARUM140LTE5 / ARUM160LTE5 / ARUM180LTE5 / ARUM200LTE5

ARUM080LTE5 / ARUM100LTE5 / ARUM120LTE5

ARUM080LTE5

OUTDOOR
ARUM080LTE5
2. Dimensions
Multi V 5
ARUM220LTE5 / ARUM240LTE5 / ARUM260LTE5

2.
Multi
2. Dimensions
Multi

2.
Multi V 5

UNITS
[Unit : mm] No. Part Name Description

2.Dimensions
Multi
1 Leakage test hole (side) Ø 22.2
2 Wire routing hole (bottom) 2-Ø 22.2 [Unit : mm] No. Part Name Description
3 Power cord routing hole (bottom) 2-Ø 50 1 Leakage test hole (side) Ø 22.2

Dimensions
4 Pipe routing hole (front) - 2 Wire routing hole (bottom) 2-Ø 22.2

Dimensions
5 Pipe routing hole (bottom) 2-Ø 66, Ø 53.88 3 Power cord routing hole (bottom) 2-Ø 50
6 Power cord routing hole (front) 2-Ø 45 4 Pipe routing hole (front) -

ARUM080LTE5 / ARUM100LTE5 / ARUM120LTE5


5 Pipe routing hole (bottom) 2-Ø 66, Ø 53.88
t
7 Wire routing hole (front) 2-Ø 30

VV5
V5
Gravity point

2. Dimensions
Multi V 5
point Gravity
point point
6 Power cord routing hole (front) 2-Ø 45

Gravity
7 Wire routing hole (front) 2-Ø 30

MULTI V 5
ARUM220LTE5 / ARUM240LTE5 / ARUM260LTE5
ARUM140LTE5
5
2. Dimensions
Multi V 5
/ /ARUM100LTE5

/ ARUM100LTE5 / ARUM120LTE5
ARUM100LTE5/ /ARUM120LTE5

/ ARUM160LTE5 / ARUM180LTE5 / ARUM200LTE5


3D View
3D View

ARUM120LTE5
[mm(inch)]
1,690

1,690
System Heat Recovery Heat Pump
Liquid Low Pressure High Pressure Liquid Gas
HP
pipe Gas pipe Gas pipe pipe pipe

14~16 Ø 12.7 (1/2) Ø 28.58 (1-1/8) Ø 22.2 (7/8) Ø 12.7 (1/2) Ø 28.58 (1-1/8)
[mm(inch)] 18~20 Ø 15.88 (5/8) Ø 28.58 (1-1/8) Ø 22.2 (7/8) Ø 15.88 (5/8) Ø 28.58 (1-1/8)
799

System Heat Recovery Heat Pump 22 Ø 15.88 (5/8) Ø 28.58(1-1/8) Ø 28.58 (1-1/8) Ø 15.88 (5/8) Ø 28.58 (1-1/8)

705
Liquid Low Pressure High Pressure Liquid Gas 24 Ø 15.88 (5/8) Ø 34.9(1-3/8) Ø 28.58 (1-1/8) Ø 15.88 (5/8) Ø 34.9 (1-3/8)
HP
pipe Gas pipe Gas pipe pipe pipe
165 165 26~34 Ø 19.05 (3/4) Ø 34.9 (1-3/8) Ø 28.58 (1-1/8) Ø 19.05 (3/4) Ø 34.9 (1-3/8)
92 175

92 176
8 Ø 9.52 (3/8) Ø 19.05 (3/4) Ø 15.88 (5/8) Ø 9.52 (3/8) Ø 19.05 (3/4)
36~40 Ø 19.05 (3/4) Ø 41.3 (1-5/8) Ø 28.58 (1-1/8) Ø 19.05 (3/4) Ø 41.3 (1-5/8)
219

220
10 Ø 9.52 (3/8) Ø 22.2 (7/8) Ø 19.05 (3/4) Ø 9.52 (3/8) Ø 22.2 (7/8)
162

162
141

140
42~60 Ø 19.05 (3/4) Ø 41.3 (1-5/8) Ø 34.9 (1-3/8) Ø 19.05 (3/4) Ø 41.3 (1-5/8)
12 Ø 12.7 (1/2) Ø 28.58 (1-1/8) Ø 19.05 (3/4) Ø 12.7 (1/2) Ø 28.58 (1-1/8)
62~64 Ø 22.2 (7/8) Ø 44.5 (1-3/4) Ø 41.3 (1-5/8) Ø 22.2 (7/8) Ø 44.5 (1-3/4)
144 159 71 71 138 159 System
66~96 Ø 22.2 (7/8) Ø 53.98 (2-1/8) Ø 44.5 (1-3/4) Ø 22.2 (7/8) Ø 53.98 (2-1/8) 71 71
462 439
414 444 442.5 System
HP
625
670 503
760
675 760 508 HP
14~16
735 593
740 1,240 18~20Ø 1
14~16
930
[mm(inch)]
Outdoor Units

[mm(inch)] [mm(inch)] [mm(inch)] 22 Ø 1


18~20
System Heat Recovery 302 Heat Pump [mm(inch)]
System System System
Heat Recovery Heat Recovery Heat Recovery Heat Pump Heat Pump Heat Pump 22 24 Ø 1
System Heat Recovery Heat Pump

Outdoor Units
280
333 Liquid Low Pressure
Liquid High Pressure Liquid GasLiquid Gas
HP Liquid Low Liquid
Low PressureLow High Liquid
Pressure Gas Liquid Gas 26~34Ø 1
HP pipe HP GasLiquidHP Pressure
pipe Gas
High
pipe
Pressure Pressure
pipe Highpipe
Pressure 24
Gas pipe GasLiquid Gas
pipe Low Pressure 267Pressure
High pipe pipe
312 pipe
HP Gas pipe pipe Gas Gas
pipe pipeGas pipe pipe pipe pipe pipe
pipe Gas pipe Gas pipe
214
pipe pipe 36~40Ø 1
26~34
298 8 Ø 9.52 (3/8) 8 Ø 19.05 (3/4)(3/8)Ø 15.88 (5/8)(3/4)Ø 9.52 (3/8)(5/8)
Ø 19.05 (3/4)(3/8) Ø 19.05 (3/4)
8 Ø 9.52 (3/8) Ø 9.52
Ø 819.05 Ø 19.05
Ø 9.52
(3/4) Ø(3/8)
15.88Ø(5/8) Ø 15.88
19.05 (3/4) Ø 9.52
Ø 15.88
Ø 9.52 (3/8) Ø(5/8) Ø 9.52 (3/8) Ø 19.05 (3/4)
19.05 (3/4)
42~60Ø 1
36~40
Ø 9.52 (3/8)810 Ø 22.2
Ø 9.52
(7/8)(3/8) ØØ 19.05 (3/4) Ø Ø 15.88 (5/8) Ø 22.2
Ø 9.52 (3/8) Ø 19.05 (3/4)
245 205
10 19.05 (3/4) 9.52 (3/8) (7/8)
10 Ø 9.52 (3/8) Ø 9.52
Ø1022.2(3/8) Ø 22.2
Ø 9.52
(7/8) Ø (7/8)Ø(3/4)
(3/8)
19.05 Ø 19.05
22.2
154 (7/8)
(3/4)
Ø 9.52 Ø 9.52
Ø 19.05
(3/8) Ø(3/4)(3/8)
22.2 Ø 22.2
Ø 9.52
(7/8) (3/8)(7/8)Ø 22.2 (7/8)
236 10 Ø 9.52 (3/8) Ø 22.2 (7/8) Ø 19.05 (3/4) Ø 9.52 (3/8) Ø 22.2 (7/8) 62~64Ø 1
42~60
51

12 Ø 12.7 (1/2)12Ø 28.58 (1-1/8) Ø 19.05 (3/4) Ø 12.7 (1/2) Ø 28.58 (1-1/8)
185 12 Ø 12.7 (1/2) ØØ12.7
12
28.58(1/2)ØØ 12.7
(1-1/8) 28.58
Ø (1-1/8)
(1/2)
19.05 Ø(3/4) Ø 19.05
28.58
125 (1-1/8)
Ø 12.7(3/4) ØØ
Ø 19.05
(1/2) 12.7 (1/2)
(3/4)
28.58 Ø 28.58
Ø 12.7
(1-1/8) (1/2)(1-1/8)
Ø 28.58 (1-1/8)
156
12 Ø 12.7 (1/2) Ø 28.58 (1-1/8) Ø 19.05 (3/4) Ø 12.7 (1/2) Ø 28.58 (1-1/8) 66~96Ø 2
62~64

109

(Pitch of foundation bolt holes)


121

92
66~96 Ø2

189
76

(Pitch of foundation bolt holes)


114
172

76
731

Outdoor Units

Outdoor
100 1,040

Outdoor Units

Outdoor Units
101 730

OutdoorUnits
(Pitch of foundation bolt holes) (Pitch of foundation bolt holes)

Units
034 / 035
OUTDOOR UNIT _ MULTI V 5 _ Q&A

MULTI V 5 Q&A MULTI V 5 Q&A

OUTDOOR
UNITS
Q1 What are the differences between MULTI V IV and MULTI V 5? Q3 How does MULTI V 5 operate when humidity reference of the dual sensing SLC is that of the outdoor?
A1 Category MULTI V IV H/P (ARUN***LTE4) MULTI V 5 H/P & H/R (ARUM***LTE5) A3 During dual sensing SLC, outdoor unit changes target pressure of the system referring to temperature and humidity in cooling mode.

MULTI V 5
-W
 hen the humidity of outdoor side is higher than that of indoor side, outdoor unit will lower target pressure to remove humidity, thus
Vapor Injection ◯ ◯
outdoor unit will consume more energy and indoor will be more cooled compared to SLC operation but more efficiency than normal operation
HiPORTM ◯ ◯

Smart Oil Control (Oil Level Sensor) ◯ ◯


Outdoor humidity is higher than indoor unit Evaporation temperature & efficiency
Active Refrigerant Control ◯ ◯ Outdoor unit will consume more energy Dual Sensing SLC (RH 70%↑)
Variable Heat Exchanger Circuit ◯ ◯ Relative Humidity >70%

Continuous Heating ◯ ◯ Discharge


SLC under the high humidity condition
Temperature
Smart Load Control ◯ ◯ (˚C)

Dual sensing (Humidity Sensor) - ◯


Normal operation (non -SLC)
Comfort Cooling ◯ ◯
20°C 25°C 30°C 35°C
Ocean Black Fin - ◯ Discharge air will be more cold than normal or
SLC operation Efficiency SLC under the high humidity condition
(%)
Maximum Capacity (1 Unit / 4 Unit) 20 HP / 80 HP 26 HP / 96 HP

Height Difference (ODU ~ IDU / IDU ~ IDU) 110m / 40m 110m / 40m
Normal operation (non -SLC)
Cooling Operating Range (OAT, °CDB) -10 ~ 43 -15 ~ 48
20°C 25°C 30°C 35°C
Heating Operating Range (OAT, °CWB) -25 ~ 18 -25 ~ 18

1 Unit 50 ~ 200% 50 ~ 200% - When the humidity of outdoor side is lower than that of indoor side, outdoor unit will rise target pressure to save energy and keep
Combination ratio of
2 Unit 50 ~ 160% 50 ~ 160% comfort, but indoor humidity will be less removed compared to normal operation.
IDU
3 or 4 Units 50 ~ 130% 50 ~ 130%
Outdoor humidity is lower than indoor unit Evaporation temperature & efficiency
※ ○ : Applied, - : Not Applied
Outdoor unit will consume less energy Dual Sensing SLC (Low Humidity)
30%< Relative Humidity< 50%

Discharge SLC under the low humidity condition


Q2 Can MULTI V 5 ODU be connected with the 2 series indoor unit? Temperature
(˚C)
A2 Yes, MULTI V 5 ODU can be connected with the 2 series indoor unit. In this case, the ODU DIP Switch No.3 should be “OFF” which is
default setting. Refer to the below table. Normal operation (non -SLC)

ODU IDU Compatibility ODU DIP Switch No. 3 If dip switch setting is not correct Ref. 20°C 25°C 30°C 35°C
Discharge air will be less cold than normal or
SLC operation. Efficiency SLC under the low humidity condition
Can not communicate between Indoor (%)
Must be OFF
Gen. 2 (ARNU*2) ◯ & Outdoor unit
(factory default)
(System will not be operated)

Normal operation (non -SLC)


When Dip Switch No. 3 is OFF, 20°C 25°C 30°C 35°C
MULTI V IV Must be ON to enable
Gen. 4 (ARNU*4) ◯ System can be operated, but
MULTI V 5 gen. 4 functions
some function of Gen. 4 is not available
To maximize comfort and energy efficiency, the outdoor unit's humidity sensing can be turned off or a standard remote control can be
When Dip Switch No. 3 is ON, installed to sense indoor humidity.
Must be OFF Can not communicate between Gen. Some functions of
Gen. 2 + Gen. 4 ◯
(factory default) 2 Indoor & Outdoor unit (Gen 2 units are not Gen.4 are not available
operated), only Gen 4 Units are operated. Sensing point SLC Setting
CASE 1. Dual Sensing SLC with Outdoor humidity sensor in ODU Setting
※ ○ : Applied, - : Not Applied Outdoor humidity
by humidity sensor (ODU) DIP-SW01

ODU dip switch setting procedure (No.3) 7-Segment

ODU main PCB dip switch is all “OFF” at default state SW04C ( X : cancel) Setting summary
SW03C (▶: forward) DIP-SW01 #5 On
(1) Check and make sure that all connected indoor units are 4 series. (ARNU******4.) SW02C (◀ : backward) Func > Fn14 >
(2) Change Dip switch No. 3 from OFF → ON Off, op1 ~ op3
SW01C (●: Confirm/
(3) Push the reset button. Automatic Addressing)
SW01D (reset)
Dip Switch 7 segment
Indoor humidity CASE 2. Dual Sensing SLC with Indoor humidity sensor in New Standard
ON ON R/C setting (PREMTB100)

Setting summary
Reset Function>
button Smart Load Control>
Off, op1 ~ op3
1 2 3 4 5 6 7 1 2 3 4 5 6 7
1 2 3 4 5 6 7 1 2 3 4 5 6 7
※ User can turn off humidity control in ODU Setting (humidity reference)
<Setting summary> ODU DIP-SW01 #5 On > Func > Fn16 > Off

036 / 037
OUTDOOR UNIT _ MULTI V 5 _ Q&A

MULTI V 5 Q&A

OUTDOOR
UNITS
Q4 What is the principle and accuracy of humidity sensor? Other Questions
A4 Total Tolerance (%) = Sensor measurement tolerance (%) + Location of sensor tolerance (%) Item Question Answer

MULTI V 5
Upper electrode
The capacitive measurement principle established and proved itself as a standard in the past. Thin-film polymer
For this principle, the sensor element is built out of a capacitor. The dielectric is a polymer Lower electrode The static pressure of MULTI V 5 is Max.
Fan Yes, the static pressure of MULTI V 5 is the same as MULTI V IV.
which absorbs or releases water proportional to the relative environmental humidity, and thus Glass substrate 8 mmAq as MULTI V IV??
changes the capacitance of the capacitor. This change in capacitance can be measured by an
electronic circuit. For humidity sensors with CMOSensⓇ technology, a “micro-machined” finger
electrode system with different protective and polymer cover layers forms the capacitance for Is the limitation of Compressor max. Hz applied by the capacity of No, the limitation of comp Hz is not applied for default. But, it can be set by
Compressor
the sensor chip, and, in addition to providing the sensor property, simultaneously protects the outdoor unit? option for limitation of max Hz (or current).
sensor from interference in ways previously not achieved.

Model Humidity Sensor of Outdoor Humidity Sensor of R/Controller MULTI V 5 has the function of both H/P and H/R by one unit.

Size (mm) 3 x 3 x 1.1 2.5 x 2.5 x 0.9 Main valve has a function to change the operation mode.
4Way V/V The usage of main & sub 4 way valve for MULTI V 5 ?
(cooling ↔ heating) Sub. Valve has a functions to change the
Supply voltage range 2.1 to 3.6 V 2.4 to 5.5 V product type (H/P ↔ H/R)

RH operating range 0 ~ 100% RH 0 ~ 100% RH

T operating range -40 to +125°C (-40 to +257°F) -40 to +125°C (-40 to +257°F) The optimal middle pressure for vapor injection is 1.2 PS.
VI In case of vapor injection, how much is the middle pressure?
RH response time 8 sec (tau 63%) 8 sec (tau63%) PS : Suction pressure of compressor

By how much is heating capacity increased


VI Generally, the heating capacity is increased up to 15 ~ 20%.
by vapor injection?

Q5 What is difference in refrigerant piping connection between heat pump and heat recovery?
Humidity
A5 From MULTI V 5, Low pressure gas pipe in heat pump operation changes to high pressure gas pipe in heat recovery operation Sensor
Where is Indoor Humidity sensor? It is placed inside of the RS3 remote controller.
due to internal cycle. So for heat pump cycle, no. 1, 3 pipe should be connected and for heat recovery operation, No. 1,2,3 pipe is
connected. (For the heat pump operation, DO NOT connect No.2 pipe)

Remote Does remote controller show the humidity information (status) Yes. It shows the current humidity information on screen.

Heat Recovery Installation Heat Pump Installation Controller as well? (for RS3 Only) But has no function to control the humidity

Close Close
Remote Is it possible to connect the local humidity sensor with Remote No. All of RS3 remote controller can not be connected with local humidity
Controller controller (RS3)? sensor.

Close Close
1 Close 2 3 1 2 3
Close
SLC Does dual sensing SLC function control the humidity ratio? No. There is no control of humidity ratio.
High Pressure
Low Pressure
Liquide pipe

Liquide pipe
Gas pipe

Gas pipe

Gas pipe

Is SLC fully used on Eurovent? Isn’t humdity fixed


SLC Eurovent (RH 47%) and AHRI (RH 51%) have fixed humidity test condition.
for the test? What about AHRI?
Reducer for Gas Pipe

8HP 9.52 19.05 15.88 8HP 9.52 No Use 19.05 15.88 19.05
Comfort cooling need super heating controlled and Comfort heating need
10HP 9.52 22.2 19.05 10HP 9.52 No Use 22.2 19.05 22.2 Comfort
Why is not the comfort heating applied in product? sub cooling controlled. In case of controlling EEV for sub cooling, noise and
Cooling
20HP 15.88 28.58 22.2 20HP 15.88 No Use 28.58 stable operation may be affected and critical.
22.2 28.58

※ For using as Heat Pump, Reducer for Gas pipe should be used.
Reducer is included in outdoor unit.
Does the IDU – Central controller direct connection for
Installation No, it is not possible.
communication cable is possible? (Flat connection)

038 / 039
OUTDOOR UNIT _ MULTI V 5 _ SPECIFICATION

MULTI V 5 MULTI V 5

OUTDOOR
UNITS
ARUM080LTE5 / ARUM100LTE5 ARUM160LTE5 / ARUM180LTE5
ARUM120LTE5 / ARUM140LTE5 ARUM200LTE5 / ARUM220LTE5

LG participates in the ECP programme for EUROVENT LG participates in the ECP programme for EUROVENT
VRF program. Check ongoing validity of certification VRF program. Check ongoing validity of certification
: www.eurovent-certification.com : www.eurovent-certification.com

HP 8 10 12 14 HP 16 18 20 22
Combination Unit ARUM080LTE5 ARUM100LTE5 ARUM120LTE5 ARUM140LTE5 Combination Unit ARUM160LTE5 ARUM180LTE5 ARUM200LTE5 ARUM220LTE5
Model Name Model Name
Independent Unit ARUM080LTE5 ARUM100LTE5 ARUM120LTE5 ARUM140LTE5 Independent Unit ARUM160LTE5 ARUM180LTE5 ARUM200LTE5 ARUM220LTE5
Cooling (Rated) kW 22.4 28.0 33.6 39.2 Cooling (Rated) kW 44.8 50.4 56.0 61.6
Capacity Heating (Rated) kW 22.4 28.0 33.6 39.2 Capacity Heating (Rated) kW 44.8 50.4 56.0 61.6
Heating (Max) kW 25.2 31.5 37.8 44.1 Heating (Max) kW 50.4 56.7 63.0 69.3
Cooling (Rated) kW 4.49 5.80 7.58 8.68 Cooling (Rated) kW 10.89 10.91 12.77 15.70
Input Heating (Rated) kW 3.97 4.92 6.85 8.13 Input Heating (Rated) kW 10.28 10.12 12.20 14.15
Heating (Max) kW 4.78 5.92 8.26 9.72 Heating (Max) kW 12.39 11.94 14.69 16.76
EER 4.99 4.83 4.43 4.52 EER 4.11 4.62 4.39 3.92
SEER 10.1 9.7 9.59 8.89 SEER 8.38 8.23 8.05 7.51
Rated Capacity 5.64 5.69 4.91 4.82 Rated Capacity 4.36 4.98 4.59 4.35
COP COP
Max. Capacity 5.27 5.32 4.58 4.54 Max. Capacity 4.07 4.75 4.29 4.13
SCOP 4.69 4.51 5.01 4.63 SCOP 4.83 4.0 3.98 3.9
Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray
Exterior Exterior
RAL Code (Classic) RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL Code (Classic) RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037
Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 1 (Inverter) x 1 (Inverter) x 1 (Inverter) x 1 Combination x No. (Inverter) x 1 (Inverter) x 2 (Inverter) x 2 (Inverter) x 2
Motor Output x Motor Output x
Compressor W x No. 4,200 x 1 5,300 x 1 5,300 x 1 5,300 x 1 Compressor W x No. 5,300 x 1 (5,300 x 1) + (4,200 x 1) (5,300 x 1) + (4,200 x 1) (5,300 x 1) + (4,200 x 1)
Number Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 3,900 3,900 3,900 3,900 Oil Charge cc 3,900 5,200 5,200 5,200
Type Propeller fan Propeller fan Propeller fan Propeller fan Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Motor Output x
W x No. 1,200 x 1 1,200 x 1 1,200 x 1 900 x 2 W x No. 900 x 2 900 x 2 900 x 2 900 x 2
Number Number
Fan Air Flow Rate (High) m /min x No.
3
240 x 1 240 x 1 240 x 1 320 x 1 Fan Air Flow Rate (High) m /min x No.
3
320 x 1 320 x 1 320 x 1 320 x 1
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 12.7 (1/2) Ø 12.7 (1/2) Pipe Liquid Pipe mm (inch) Ø 12.7 (1/2) Ø 15.88 (5/8) Ø 15.88 (5/8) Ø 15.88 (5/8)
Connections Connections
Low Pressure Gas Pipe mm (inch) Ø 19.05 (3/4) Ø 22.2 (7/8) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8) Low Pressure Gas Pipe mm (inch) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8)
for Heat for Heat
Recovery High Pressure Gas Pipe mm (inch) Ø 15.88 (5/8) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 22.2 (7/8) Recovery High Pressure Gas Pipe mm (inch) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 28.58 (1-1/8)
Pipe Liquid Pipe mm (inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 12.7 (1/2) Ø 12.7 (1/2) Pipe Liquid Pipe mm (inch) Ø 12.7 (1/2) Ø 15.88 (5/8) Ø 15.88 (5/8) Ø 15.88 (5/8)
Connections Connections
for Heat Pump Gas Pipe mm (inch) Ø 19.05 (3/4) Ø 22.2 (7/8) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8) for Heat Pump Gas Pipe mm (inch) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8)
Dimensions (W x H x D) mm x No. (930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x1 Dimensions (W x H x D) mm x No. (1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1
Dimensions (W x H x D) - Shipping mm x No. (960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1 (1,280 x 1,825 x 796) x 1 Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 1 (1,280 x 1,825 x 796) x 1 (1,280 x 1,825 x 796) x 1 (1,280 x 1,825 x 796) x 1
Net Weight kg x No. 198 x 1 215 x 1 215 x 1 237 x 1 Net Weight kg x No. 237 x 1 300 x 1 300 x 1 300 x 1
Shipping Weight kg x No. 208 x 1 225 x 1 225 x 1 250 x 1 Shipping Weight kg x No. 250 x 1 312 x 1 312 x 1 312 x 1
Sound Cooling dB(A) 58.0 58.0 59.0 60.0 Sound Cooling dB(A) 60.5 61.0 62.0 64.5
Pressure Level Heating dB(A) 59.0 59.0 60.0 61.0 Pressure Level Heating dB(A) 61.5 62.0 64.5 65.5
Sound Cooling dB(A) 84.0 85.0 86.0 89.0 Sound Power Cooling dB(A) 90.0 92.0 93.0 93.0
Power Level Heating dB(A) 87.0 88.0 89.0 93.0 Level Heating dB(A) 94.0 95.0 96.0 97.0
mm2 x No. mm2 x No.
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
(VCTF-SB) (VCTF-SB)
Refrigerant Name R410A R410A R410A R410A Refrigerant Name R410A R410A R410A R410A
Precharged Amount Precharged Amount
kg 7.5 9.5 9.5 13.5 kg 13.5 16.0 16.0 16.0
Refrigerant in Factory Refrigerant in Factory
t-CO2 eq. 15.7 19.8 19.8 28.2 t-CO2 eq. 28.2 33.4 33.4 33.4
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 13 (20) 16 (25) 20 (30) 23 (35) Number of Maximum Connectable Indoor Units 1) 26 (40) 29 (45) 32 (50) 35 (56)

1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance 1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination(160% ~ 200%). The recommended ratio is 130%. with outdoor units combination(160% ~ 200%). The recommended ratio is 130%.

040 / 041
OUTDOOR UNIT _ MULTI V 5 _ SPECIFICATION

MULTI V 5 MULTI V 5

OUTDOOR
UNITS
ARUM240LTE5 / ARUM260LTE5 ARUM261LTE5 / ARUM280LTE5
ARUM221LTE5 / ARUM241LTE5 ARUM300LTE5 / ARUM320LTE5

MULTI V 5
LG participates in the ECP programme for EUROVENT LG participates in the ECP programme for EUROVENT
VRF program. Check ongoing validity of certification VRF program. Check ongoing validity of certification
: www.eurovent-certification.com : www.eurovent-certification.com

HP 24 26 22' 24' HP 26' 28 30 32


Combination Unit ARUM240LTE5 ARUM260LTE5 ARUM221LTE5 ARUM241LTE5 Combination Unit ARUM261LTE5 ARUM280LTE5 ARUM300LTE5 ARUM320LTE5
Model Name ARUM120LTE5 ARUM120LTE5 Model Name ARUM140LTE5 ARUM160LTE5 ARUM180LTE5 ARUM200LTE5
Independent Unit ARUM240LTE5 ARUM260LTE5 Independent Unit
ARUM100LTE5 ARUM120LTE5 ARUM120LTE5 ARUM120LTE5 ARUM120LTE5 ARUM120LTE5
Cooling (Rated) kW 67.2 72.8 61.6 67.2 Cooling (Rated) kW 72.8 78.4 84.0 89.6
Capacity Heating (Rated) kW 67.2 67.2 61.6 67.2 Capacity Heating (Rated) kW 72.8 78.4 84.0 89.6
Heating (Max) kW 74.3 74.3 69.3 75.6 Heating (Max) kW 81.9 88.2 94.5 100.8
Cooling (Rated) kW 17.40 20.20 13.38 15.16 Cooling (Rated) kW 16.26 18.47 18.49 20.35
Input Heating (Rated) kW 15.89 15.99 11.77 13.70 Input Heating (Rated) kW 14.98 17.13 16.97 19.05
Heating (Max) kW 18.80 19.15 14.18 16.52 Heating (Max) kW 17.98 20.65 20.20 22.95
EER 3.86 3.60 4.60 4.43 EER 4.48 4.24 4.54 4.40
SEER 7.88 7.55 - - SEER - - - -
Rated Capacity 4.23 4.20 5.23 4.91 Rated Capacity 4.86 4.58 4.95 4.70
COP COP
Max. Capacity 3.95 3.88 4.89 4.58 Max. Capacity 4.56 4.27 4.68 4.39
SCOP 4.34 4.34 - - SCOP - - - -
Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray
Exterior Exterior
RAL Code (Classic) RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL Code (Classic) RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037
Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 2 (Inverter) x 2 (Inverter) x 2 (Inverter) x 2 Combination x No. (Inverter) x 2 (Inverter) x 2 (Inverter) x 3 (Inverter) x 3
Motor Output x Motor Output x
Compressor W x No. 5,300 x 2 5,300 x 2 5,300 x 2 5,300 x 2 Compressor W x No. 5,300 x 2 5,300 x 2 (5,300 x 2) + (4,200 x 1) (5,300 x 2) + (4,200 x 1)
Number Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 5,200 5,200 7,800 7,800 Oil Charge cc 7,800 7,800 9,100 9,100
Type Propeller fan Propeller fan Propeller fan Propeller fan Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Motor Output x
W x No. 900 x 2 900 x 2 (1,200 x 1) + (1,200 x 1) (1,200 x 1) + (1,200 x 1) W x No. (900 x 2) + (1,200 x 1) (900 x 2) + (1,200 x 1) (900 x 2) + (1,200 x 1) (900 x 2) + (1,200 x 1)
Number Number
Fan Air Flow Rate (High) m3/min x No. 320 x 1 320 x 1 (240 x 1) + (240 x 1) (240 x 1) + (240 x 1) Fan Air Flow Rate (High) m3/min x No. (320 x 1) + (240 x 1) (320 x 1) + (240 x 1) (320 x 1) + (240 x 1) (320 x 1) + (240 x 1)
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) Ø 15.88 (5/8) Ø 19.05 (3/4) Ø 15.88 (5/8) Ø 15.88 (5/8) Pipe Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4)
Connections Connections
Low Pressure Gas Pipe mm (inch) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Ø 28.58 (1-1/8) Ø 34.9 (1-3/8) Low Pressure Gas Pipe mm (inch) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8)
for Heat for Heat
Recovery High Pressure Gas Pipe mm (inch) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8) Recovery High Pressure Gas Pipe mm (inch) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8)
Pipe Liquid Pipe mm (inch) Ø 15.88 (5/8) Ø 19.05 (3/4) Ø 15.88 (5/8) Ø 15.88 (5/8) Pipe Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4)
Connections Connections
for Heat Pump Gas Pipe mm (inch) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Ø 28.58 (1-1/8) Ø 34.9 (1-3/8) for Heat Pump Gas Pipe mm (inch) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8)
(930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1 + (1,240 x 1,690 x 760) x 1 + (1,240 x 1,690 x 760) x 1 + (1,240 x 1,690 x 760) x 1 + (1,240 x 1,690 x 760) x 1 +
Dimensions (W x H x D) mm x No. (1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1 Dimensions (W x H x D) mm x No.
(930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1
(960 x 1,825 x 796) x 1 + (960 x 1,825 x 796) x 1 + (1,280 x 1,825 x 796) x 1 + (1,280 x 1,825 x 796) x 1 + (1,280 x 1,825 x 796) x 1 + (1,280 x 1,825 x 796) x 1 +
Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 1 (1,280 x 1,825 x 796) x 1 Dimensions (W x H x D) - Shipping mm x No.
(960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1
Net Weight kg x No. 310 x 1 310 x 1 (215 x 1) + (215 x 1) (215 x 1) + (215 x 1) Net Weight kg x No. (237 x 1) + (215 x 1) (237 x 1) + (215 x 1) (300 x 1) + (215 x 1) (300 x 1) + (215 x 1)
Shipping Weight kg x No. 320 x 1 320 x 1 (225 x 1) + (225 x 1) (225 x 1) + (225 x 1) Shipping Weight kg x No. (250 x 1) + (225 x 1) (250 x 1) + (225 x 1) (312 x 1) + (225 x 1) (312 x 1) + (225 x 1)
Sound Cooling dB(A) 65.0 65.0 61.5 62.0 Sound Cooling dB(A) 62.5 62.8 63.1 63.8
Pressure Level Heating dB(A) 67.0 67.0 62.5 63.0 Pressure Level Heating dB(A) 63.5 63.8 64.1 65.8
Sound Power Cooling dB(A) 95.0 95.0 88.5 89.0 Sound Power Cooling dB(A) 90.8 91.5 93.0 93.8
Level Heating dB(A) 99.0 99.0 91.5 92.0 Level Heating dB(A) 94.5 95.2 96.0 96.8
mm2 x No. mm2 x No.
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
(VCTF-SB) (VCTF-SB)
Refrigerant Name R410A R410A R410A R410A Refrigerant Name R410A R410A R410A R410A
Precharged Amount Precharged Amount
kg 17.0 17.0 19.0 19.0 kg 23.0 23.0 25.5 25.5
Refrigerant in Factory Refrigerant in Factory
t-CO2 eq. 35.5 35.5 39.7 39.7 t-CO2 eq. 48.0 48.0 53.2 53.2
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 39 (61) 42 (64) 35 (44) 39 (48) Number of Maximum Connectable Indoor Units 1) 42 (52) 45 (56) 49 (60) 52 (64)

1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance 1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination(160% ~ 200%). The recommended ratio is 130%. with outdoor units combination(160% ~ 200%). The recommended ratio is 130%.

042 / 043
OUTDOOR UNIT _ MULTI V 5 _ SPECIFICATION

MULTI V 5 MULTI V 5

OUTDOOR
UNITS
ARUM340LTE5 / ARUM360LTE5 ARUM420LTE5 / ARUM440LTE5
ARUM380LTE5 / ARUM400LTE5 ARUM460LTE5 / ARUM480LTE5

MULTI V 5
HP 34 36 38 40 HP 42 44 46 48
Combination Unit ARUM340LTE5 ARUM360LTE5 ARUM380LTE5 ARUM400LTE5 Combination Unit ARUM420LTE5 ARUM440LTE5 ARUM460LTE5 ARUM480LTE5
Model Name ARUM220LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
Independent Unit Independent Unit
ARUM120LTE5 ARUM120LTE5 ARUM140LTE5 ARUM160LTE5 ARUM180LTE5 ARUM200LTE5 ARUM220LTE5 ARUM240LTE5
Cooling (Rated) kW 95.2 100.8 106.4 112.0 Cooling (Rated) kW 117.6 123.2 128.8 134.4
Capacity Heating (Rated) kW 95.2 100.8 106.4 112.0 Capacity Heating (Rated) kW 117.6 123.2 128.8 134.4
Heating (Max) kW 107.1 112.1 118.4 124.7 Heating (Max) kW 131.0 137.3 143.6 148.5
Cooling (Rated) kW 23.28 24.98 26.08 28.29 Cooling (Rated) kW 28.31 30.17 33.10 34.80
Input Heating (Rated) kW 21.00 22.74 24.02 26.17 Input Heating (Rated) kW 26.01 28.09 30.04 31.78
Heating (Max) kW 25.02 27.06 28.52 31.19 Heating (Max) kW 30.74 33.48 35.56 37.60
EER 4.09 4.04 4.08 3.96 EER 4.15 4.08 3.89 3.86
SEER - - - - SEER - - - -
Rated Capacity 4.53 4.43 4.43 4.28 Rated Capacity 4.52 4.39 4.29 4.23
COP COP
Max. Capacity 4.28 4.14 4.15 4.00 Max. Capacity 4.26 4.10 4.04 3.95
SCOP - - - - SCOP - - - -
Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray
Exterior Exterior
RAL Code (Classic) RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL Code (Classic) RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037
Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 3 (Inverter) x 3 (Inverter) x 3 (Inverter) x 3 Combination x No. (Inverter) x 4 (Inverter) x 4 (Inverter) x 4 (Inverter) x 4
Motor Output x Motor Output x
Compressor W x No. (5,300 x 2) + (4,200 x 1) 5,300 x 3 5,300 x 3 5,300 x 3 Compressor W x No. (5,300 x 3) + (4,200 x 1) (5,300 x 3) + (4,200 x 1) (5,300 x 3) + (4,200 x 1) 5,300 x 4
Number Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 9,100 9,100 9,100 9,100 Oil Charge cc 10,400 10,400 10,400 10,400
Type Propeller fan Propeller fan Propeller fan Propeller fan Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Motor Output x
W x No. (900 x 2) + (1,200 x 1) (900 x 2) + (1,200 x 1) 900 x 4 900 x 4 W x No. 900 x 4 900 x 4 900 x 4 900 x 4
Number Number
Fan Air Flow Rate (High) m3/min x No. (320 x 1) + (240 x 1) (320 x 1) + (240 x 1) 320 x 2 320 x 2 Fan Air Flow Rate (High) m3/min x No. 320 x 2 320 x 2 320 x 2 320 x 2
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) Pipe Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4)
Connections Connections
Low Pressure Gas Pipe mm (inch) Ø 34.9 (1-3/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Low Pressure Gas Pipe mm (inch) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8)
for Heat for Heat
Recovery High Pressure Gas Pipe mm (inch) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Recovery High Pressure Gas Pipe mm (inch) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8)
Pipe Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) Pipe Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4)
Connections Connections
for Heat Pump Gas Pipe mm (inch) Ø 34.9 (1-3/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) for Heat Pump Gas Pipe mm (inch) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8)
(1,240 x 1,690 x 760) x 1 + (1,240 x 1,690 x 760) x 1 + Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 2 (1,240 x1,690 x 760) x 2 (1,240 x1,690 x 760) x 2 (1,240 x1,690 x 760) x 2
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 2 (1,240 x1,690 x 760) x 2
(930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1
Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 2 (1,280 x 1,825 x 796) x 2 (1,280 x 1,825 x 796) x 2 (1,280 x 1,825 x 796) x 2
(1,280 x 1,825 x 796) x 1 + (1,280 x 1,825 x 796) x 1 +
Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 2 (1,280 x 1,825 x 796) x 2 Net Weight kg x No. (310 x 1) + (300 x 1) (310 x 1) + (300 x 1) (310 x 1) + (300 x 1) 310 x 2
(960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1
Net Weight kg x No. (300 x 1) + (215 x 1) (310 x 1) + (215 x 1) (310 x 1) + (237 x 1) (310 x 1) + (237 x 1) Shipping Weight kg x No. (320 x 1) + (312 x 1) (320 x 1) + (312 x 1) (320 x 1) + (312 x 1) 320 x 2
Shipping Weight kg x No. (312 x 1) + (225 x 1) (320 x 1) + (225 x 1) (320 x 1) + (250 x 1) (320 x 1) + (250 x 1) Sound Cooling dB(A) 66.5 66.8 67.8 68.0
Sound Cooling dB(A) 65.6 66.0 66.2 66.3 Pressure Level Heating dB(A) 68.2 68.9 69.3 70.0
Pressure Level Heating dB(A) 66.6 67.8 68.0 68.1 Cooling dB(A) 96.8 97.1 97.1 98.0
Sound Power
Sound Power Cooling dB(A) 93.8 95.5 96.0 96.2 Level Heating dB(A) 100.5 100.8 101.1 102.0
Level Heating dB(A) 97.6 99.4 100.0 100.2 mm2 x No.
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
mm2 x No. (VCTF-SB)
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Refrigerant Name R410A R410A R410A R410A
(VCTF-SB)
Refrigerant Name R410A R410A R410A R410A Precharged Amount
kg 33.0 33.0 33.0 34.0
Precharged Amount Refrigerant in Factory
kg 25.5 26.5 30.5 30.5 t-CO2 eq. 68.9 68.9 68.9 71.0
Refrigerant in Factory
t-CO2 eq. 53.2 55.3 63.7 63.7 Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 Number of Maximum Connectable Indoor Units 1) 64 64 64 64
Number of Maximum Connectable Indoor Units 1) 55 (64) 58 (64) 61 (64) 64

1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance 1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination(160% ~ 200%). The recommended ratio is 130%. with outdoor units combination(160% ~ 200%). The recommended ratio is 130%.

044 / 045
OUTDOOR UNIT _ MULTI V 5 _ SPECIFICATION

MULTI V 5 MULTI V 5

OUTDOOR
UNITS
ARUM500LTE5 / ARUM520LTE5 ARUM580LTE5 / ARUM600LTE5
ARUM540LTE5 / ARUM560LTE5 ARUM620LTE5 / ARUM640LTE5
ARUM660LTE5

MULTI V 5
HP 50 52 54 56 HP 58 60 62 64 66
Combination Unit ARUM500LTE5 ARUM520LTE5 ARUM540LTE5 ARUM560LTE5 Combination Unit ARUM580LTE5 ARUM600LTE5 ARUM620LTE5 ARUM640LTE5 ARUM660LTE5
Model Name ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 Model Name ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
Independent Unit ARUM140LTE5 ARUM160LTE5 ARUM180LTE5 ARUM200LTE5 Independent Unit ARUM220LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
ARUM120LTE5 ARUM120LTE5 ARUM120LTE5 ARUM120LTE5 ARUM120LTE5 ARUM120LTE5 ARUM140LTE5 ARUM160LTE5 ARUM180LTE5
Cooling (Rated) kW 140 145.6 151.2 156.8 Cooling (Rated) kW 162.4 168.0 173.6 179.2 184.8
Capacity Heating (Rated) kW 140 145.6 151.2 156.8 Capacity Heating (Rated) kW 162.4 168.0 173.6 179.2 184.8
Heating (Max) kW 156.2 162.5 168.8 175.1 Heating (Max) kW 181.4 186.3 192.6 198.9 205.2
Cooling (Rated) kW 33.66 35.87 35.89 37.75 Cooling (Rated) kW 40.68 42.38 43.48 45.69 45.71
Input Heating (Rated) kW 30.87 33.02 32.86 34.94 Input Heating (Rated) kW 36.89 38.63 39.91 42.06 41.90
Heating (Max) kW 36.78 39.45 39 41.74 Heating (Max) kW 43.82 45.86 47.32 49.99 49.54
EER 4.16 4.06 4.21 4.15 EER 3.99 3.96 3.99 3.92 4.04
SEER - - - - SEER - - - - -
Rated Capacity 4.54 4.41 4.6 4.49 Rated Capacity 4.40 4.35 4.35 4.26 4.41
COP COP
Max. Capacity 4.25 4.12 4.33 4.19 Max. Capacity 4.14 4.06 4.07 3.98 4.14
SCOP - - - - SCOP - - - - -
Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray
Exterior Exterior
RAL Code (Classic) RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL Code (Classic) RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037
Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus /
Heat Exchanger Type
Black Fin Black Fin Black Fin Black Fin Black Fin
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed
Combination x No. (Inverter) x 4 (Inverter) x 4 (Inverter) x 5 (Inverter) x 5 Type
Scroll Scroll Scroll Scroll Scroll
Motor Output x Combination x No. (Inverter) x 5 (Inverter) x 5 (Inverter) x 5 (Inverter) x 5 (Inverter) x 6
Compressor W x No. 5,300 x 4 5,300 x 4 (5,300 x 4) + (4,200 x 1) (5,300 x 4) + (4,200 x 1)
Number Motor Output x
Compressor W x No. (5,300 x 4) + (4,200 x 1) 5,300 x 5 5,300 x 5 5,300 x 5 (5,300 x 5) + (4,200 x 1)
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) Number
Oil Charge cc 13,000 13,000 14,300 14,300 Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Type Propeller fan Propeller fan Propeller fan Propeller fan Oil Charge cc 14,300 14,300 14,300 14,300 15,600
Motor Output x Type Propeller fan Propeller fan Propeller fan Propeller fan Propeller fan
W x No. (900 x 4) + (1,200 x 1) (900 x 4) + (1,200 x 1) (900 x 4) + (1,200 x 1) (900 x 4) + (1,200 x 1)
Number Motor Output x
Fan Air Flow Rate (High) m3/min x No. (320 x 2) + (240 x 1) (320 x 2) + (240 x 1) (320 x 2) + (240 x 1) (320 x 2) + (240 x 1) W x No. (900 x 4) + (1,200 x 1) (900 x 4) + (1,200 x 1) 900 x 6 900 x 6 900 x 6
Number
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER Fan Air Flow Rate (High) m3/min x No. (320 x 2) + (240 x 1) (320 x 2) + (240 x 1) 320 x 3 320 x 3 320 x 3
Discharge Side / Top TOP TOP TOP TOP Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Pipe Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) Discharge Side / Top TOP TOP TOP TOP TOP
Connections Pipe Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8)
Low Pressure Gas Pipe mm (inch) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8)
for Heat Connections
Recovery High Pressure Gas Pipe mm (inch) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Low Pressure Gas Pipe mm (inch) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) Ø 53.98 (2-1/8)
for Heat
Pipe Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) Recovery High Pressure Gas Pipe mm (inch) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 44.5 (1-3/4)
Connections Pipe
Gas Pipe mm (inch) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8)
for Heat Pump Connections
(1,240 x 1,690 x 760) x 2 + (1,240 x 1,690 x 760) x 2 + (1,240 x 1,690 x 760) x 2 + (1,240 x 1,690 x 760) x 2 + for Heat Pump Gas Pipe mm (inch) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) Ø 53.98 (2-1/8)
Dimensions (W x H x D) mm x No.
(930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 2 (1,240 x 1,690 x 760) x 2
(1,280 x 1,825 x 796) x 2 + (1,280 x 1,825 x 796) x 2 + (1,280 x 1,825 x 796) x 2 + (1,280 x 1,825 x 796) x 2 + Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 3 (1,240 x1,690 x 760) x 3 (1,240 x1,690 x 760) x 3
Dimensions (W x H x D) - Shipping mm x No. + (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1
(960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1 (1,280 x 1,825 x 796) x 2 (1,280 x 1,825 x 796) x 2
(310 x 1) + (237 x 1) + (215 (310 x 1) + (237 x 1) + (215 (310 x 1) + (300 x 1) + (310 x 1) + (300 x 1) + Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3
Net Weight kg x No. + (960 x 1,825 x 796) x 1 + (960 x 1,825 x 796) x 1
x 1) x 1) (215 x 1) (215 x 1) (310 x 1) + (300 x 1) +
(320 x 1) + (250 x 1) + (320 x 1) + (250 x 1) + (320 x 1) + (312 x 1) + (225 (320 x 1) + (312 x 1) + (225 Net Weight kg x No. (310 x 2) + (215 x 1) (310 x 2) + (237 x 1) (310 x 2) + (237 x 1) (310 x 2) + (300 x 1)
Shipping Weight kg x No. (215 x 1)
(225 x 1) (225 x 1) x 1) x 1) (320 x 1) + (312 x 1) +
Cooling dB(A) 67 67.1 67.2 67.4 Shipping Weight kg x No. (320 x 2) + (225 x 1) (320 x 2) + (250 x 1) (320 x 2) + (250 x 1) (320 x 2) + (312 x 1)
Sound (225 x 1)
Pressure Level Heating dB(A) 68.6 68.7 68.8 69.5 Sound Cooling dB(A) 68.3 68.5 68.6 68.7 68.8
Cooling dB(A) 96.4 96.6 97.1 97.4 Pressure Level Heating dB(A) 69.8 70.4 70.5 70.6 70.6
Sound Power
Level Heating dB(A) 100.3 100.5 100.8 101 Sound Power Cooling dB(A) 97.4 98.3 98.5 98.6 99.0
mm2 x No. Level Heating dB(A) 101.4 102.2 102.5 102.6 102.8
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
(VCTF-SB) mm2 x No.
Refrigerant Name R410A R410A R410A R410A Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
(VCTF-SB)
Precharged Amount Refrigerant Name R410A R410A R410A R410A R410A
kg 40 40 42.5 42.5
Refrigerant in Factory Precharged Amount
t-CO2 eq. 83.5 83.5 88.7 88.7 kg 42.5 43.5 47.5 47.5 50.0
in Factory
Refrigerant
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve t-CO2 eq. 88.7 90.8 99.2 99.2 104.4
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion
Control
Valve Valve Valve Valve Valve
Number of Maximum Connectable Indoor Units 1) 64 64 64 64
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 64 64 64 64 64

1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance 1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination(160% ~ 200%). The recommended ratio is 130%. with outdoor units combination(160% ~ 200%). The recommended ratio is 130%.

046 / 047
OUTDOOR UNIT _ MULTI V 5 _ SPECIFICATION

MULTI V 5 MULTI V 5

OUTDOOR
UNITS
ARUM680LTE5 / ARUM700LTE5 ARUM780LTE5 / ARUM800LTE5
ARUM720LTE5 / ARUM740LTE5 ARUM820LTE5 / ARUM840LTE5
ARUM760LTE5 ARUM860LTE5

MULTI V 5
HP 68 70 72 74 76 HP 78 80 82 84 86
Combination Unit ARUM680LTE5 ARUM700LTE5 ARUM720LTE5 ARUM740LTE5 ARUM760LTE5 Combination Unit ARUM780LTE5 ARUM800LTE5 ARUM820LTE5 ARUM840LTE5 ARUM860LTE5
ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
Model Name ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 Model Name
ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
Independent Unit ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 Independent Unit
ARUM140LTE5 ARUM160LTE5 ARUM180LTE5 ARUM200LTE5 ARUM220LTE5 ARUM240LTE5 ARUM240LTE5
ARUM200LTE5 ARUM220LTE5 ARUM240LTE5
ARUM120LTE5 ARUM120LTE5 ARUM120LTE5 ARUM120LTE5 ARUM120LTE5 ARUM120LTE5 ARUM140LTE5
Cooling (Rated) kW 190.4 196.0 201.6 207.2 212.8 Cooling (Rated) kW 218.4 224.0 229.6 235.2 240.8
Capacity Heating (Rated) kW 190.4 196.0 201.6 207.2 212.8 Capacity Heating (Rated) kW 218.4 224.0 229.6 235.2 240.8
Heating (Max) kW 211.5 217.8 222.8 230.4 236.7 Heating (Max) kW 243.0 249.3 255.6 260.6 266.9
Cooling (Rated) kW 47.57 50.50 52.20 51.06 53.27 Cooling (Rated) kW 53.29 55.15 58.08 59.78 60.88
Input Heating (Rated) kW 43.98 45.93 47.67 46.76 48.91 Input Heating (Rated) kW 48.75 50.83 52.78 54.52 55.80
Heating (Max) kW 52.28 54.36 56.40 55.58 58.25 Heating (Max) kW 57.80 60.54 62.62 64.66 66.12
EER 4.00 3.88 3.86 4.06 3.99 EER 4.10 4.06 3.95 3.93 3.96
SEER - - - - - SEER - - - - -
Rated Capacity 4.33 4.27 4.23 4.43 4.35 Rated Capacity 4.48 4.41 4.35 4.31 4.32
COP COP
Max. Capacity 4.05 4.01 3.95 4.15 4.06 Max. Capacity 4.20 4.12 4.08 4.03 4.04
SCOP - - - - - SCOP - - - - -
Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray
Exterior Exterior
RAL Code (Classic) RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL Code (Classic) RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037
Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus /
Heat Exchanger Type Heat Exchanger Type
Black Fin Black Fin Black Fin Black Fin Black Fin Black Fin Black Fin Black Fin Black Fin Black Fin
Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed
Type Type
Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll
Combination x No. (Inverter) x 6 (Inverter) x 6 (Inverter) x 6 (Inverter) x 6 (Inverter) x 6 Combination x No. (Inverter) x 7 (Inverter) x 7 (Inverter) x 7 (Inverter) x 7 (Inverter) x 7
Compressor Motor Output x Compressor Motor Output x
W x No. (5,300 x 5) + (4,200 x 1) (5,300 x 5) + (4,200 x 1) 5,300 x 6 5,300 x 6 5,300 x 6 W x No. (5,300 x 6) + (4,200 x 1) (5,300 x 6) + (4,200 x 1) (5,300 x 6) + (4,200 x 1) 5,300 x 7 5,300 x 7
Number Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 15,600 15,600 15,600 18,200 18,200 Oil Charge cc 19,500 19,500 19,500 19,500 19,500
Type Propeller fan Propeller fan Propeller fan Propeller fan Propeller fan Type Propeller fan Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Motor Output x
W x No. 900 x 6 900 x 6 900 x 6 (900 x 6) + (1,200 x 1) (900 x 6) + (1,200 x 1) W x No. (900 x 6) + (1,200 x 1) (900 x 6) + (1,200 x 1) (900 x 6) + (1,200 x 1) (900 x 6) + (1,200 x 1) 900 x 8
Number Number
Fan Air Flow Rate (High) m /min x No.
3
320 x 3 320 x 3 320 x 3 (320 x 3) + (240 x 1) (320 x 3) + (240 x 1) Fan Air Flow Rate (High) m /min x No.
3
(320 x 3) + (240 x 1) (320 x 3) + (240 x 1) (320 x 3) + (240 x 1) (320 x 3) + (240 x 1) 320 x 4
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER DC INVERTER Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP TOP Discharge Side / Top TOP TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Pipe Liquid Pipe mm (inch) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8)
Connections Connections
Low Pressure Gas Pipe mm (inch) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Low Pressure Gas Pipe mm (inch) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8)
for Heat for Heat
Recovery High Pressure Gas Pipe mm (inch) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) Recovery High Pressure Gas Pipe mm (inch) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4)
Pipe Liquid Pipe mm (inch) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Pipe Liquid Pipe mm (inch) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8)
Connections Connections
for Heat Pump Gas Pipe mm (inch) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) for Heat Pump Gas Pipe mm (inch) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8)
(1,240 x 1,690 x 760) x 3 (1,240 x 1,690 x 760) x 3 (1,240 x 1,690 x 760) x 3 (1,240 x 1,690 x 760) x 3 (1,240 x 1,690 x 760) x 3 (1,240 x 1,690 x 760) x 3
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 3 (1,240 x1,690 x 760) x 3 (1,240 x1,690 x 760) x 3 Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 4
+ (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1
(1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3
Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3 Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 4
+ (960 x 1,825 x 796) x 1 + (960 x 1,825 x 796) x 1 + (960 x 1,825 x 796) x 1 + (960 x 1,825 x 796) x 1 + (960 x 1,825 x 796) x 1 + (960 x 1,825 x 796) x 1
(310 x 2) + (237 x 1) + (310 x 2) + (237 x 1) + (310 x 2) + (300 x 1) + (310 x 2) + (300 x 1) + (310 x 2) + (300 x 1) +
Net Weight kg x No. (310 x 2) + (300 x 1) (310 x 2) + (300 x 1) 310 x 3 Net Weight kg x No. (310 x 3) + (215 x 1) (310 x 3) + (237 x 1)
(215 x 1) (215 x 1) (215 x 1) (215 x 1) (215 x 1)
(320 x 2) + (250 x 1) + (320 x 2) + (250 x 1) + (320 x 2) + (312 x 1) + (320 x 2) + (312 x 1) + (320 x 2) + (312 x 1) +
Shipping Weight kg x No. (320 x 2) + (312 x 1) (320 x 2) + (312 x 1) 320 x 3 Shipping Weight kg x No. (320 x 3) + (225 x 1) (320 x 3) + (250 x 1)
(225 x 1) (225 x 1) (225 x 1) (225 x 1) (225 x 1)
Sound Cooling dB(A) 69.0 69.6 69.8 69.1 69.2 Sound Cooling dB(A) 69.2 69.4 70.0 70.1 70.2
Pressure Level Heating dB(A) 71.1 71.3 71.8 70.9 70.9 Pressure Level Heating dB(A) 71.0 71.4 71.6 72.1 72.1
Sound Power Cooling dB(A) 99.2 99.2 99.8 98.8 98.9 Sound Power Cooling dB(A) 99.2 99.4 99.4 99.9 100.1
Level Heating dB(A) 103.0 103.2 103.8 102.7 102.8 Level Heating dB(A) 103.0 103.2 103.4 103.9 104.1
mm2 x No. mm2 x No.
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
(VCTF-SB) (VCTF-SB)
Refrigerant Name R410A R410A R410A R410A R410A Refrigerant Name R410A R410A R410A R410A R410A
Precharged Amount Precharged Amount
kg 50.0 50.0 51.0 57.0 57.0 kg 59.5 59.5 59.5 60.5 64.5
in Factory in Factory
Refrigerant Refrigerant
t-CO2 eq. 104.4 104.4 106.5 119.0 119.0 t-CO2 eq. 124.2 124.2 124.2 126.3 134.6
Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion
Control Control
Valve Valve Valve Valve Valve Valve Valve Valve Valve Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 64 64 64 64 64 Number of Maximum Connectable Indoor Units 1) 64 64 64 64 64

1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance 1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination(160% ~ 200%). The recommended ratio is 130%. with outdoor units combination(160% ~ 200%). The recommended ratio is 130%.

048 / 049
OUTDOOR UNIT _ MULTI V 5 _ SPECIFICATION OUTDOOR UNIT _ MULTI V 5 _ NOTE

MULTI V 5 NOTES

OUTDOOR
UNITS
ARUM880LTE5 / ARUM900LTE5
1. Eurovent Test Condition : For more info regarding program consult www.eurovent-certification.com
ARUM920LTE5 / ARUM940LTE5
ARUM960LTE5

MULTI V 5
2. Capacities are based on the following conditions :
• Cooling Temperature : Indoor 27°C (80.6°F) DB / 19°C (66.2°F) WB Outdoor 35°C (95°F) DB / 24°C (75.2°F) WB
• Heating Temperature : Indoor 20°C (68°F) DB / 15°C (59°F) WB Outdoor 7°C (44.6°F) DB / 6°C (42.8°F) WB
• Piping Length : Interconnected Pipe Length = 7.5m
• Difference Limit of Elevation (Outdoor ~ Indoor Unit) is 0m.

HP 88 90 92 94 96
Combination Unit ARUM880LTE5 ARUM900LTE5 ARUM920LTE5 ARUM940LTE5 ARUM960LTE5
3. Wiring cable size must comply with the applicable local and national code.
ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
Model Name ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
Independent Unit
ARUM240LTE5
ARUM160LTE5
ARUM240LTE5
ARUM180LTE5
ARUM240LTE5
ARUM200LTE5
ARUM240LTE5
ARUM220LTE5
ARUM240LTE5
ARUM240LTE5
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Cooling (Rated) kW 246.4 252.0 257.6 263.2 268.8 Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Capacity Heating (Rated) kW 246.4 252.0 257.6 263.2 268.8
Therefore, these values can be increased owing to ambient conditions during operation.
Heating (Max) kW 273.2 279.5 285.8 292.1 297.0
Cooling (Rated) kW 63.09 63.11 64.97 67.90 69.60
Input Heating (Rated) kW 57.95 57.79 59.87 61.82 63.56 5. Explanation of Terms
Heating (Max) kW 68.79 68.34 71.08 73.16 75.19
• EER : Energy Efficiency Ratio (Cooling)
EER 3.91 3.99 3.96 3.88 3.86
SEER - - - - - • SEER : Seasonal Energy Efficiency Ratio (Refer to Typical Cooling Season)
Rated Capacity 4.25 4.36 4.30 4.26 4.23 • COP : Coefficient Of Performance (Heating)
COP
Max. Capacity 3.97 4.09 4.02 3.99 3.95
SCOP - - - - -
• SCOP : Seasonal Coefficient Of Performance (Refer to Typical Heating Season)
Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037 RAL 7044 / RAL 7037
6. Due to our policy of innovation some specifications may be changed without notification.
Heat Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus /
Type
Exchanger Black Fin Black Fin Black Fin Black Fin Black Fin
Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed
Type
Scroll Scroll Scroll Scroll Scroll 7. This product contains Fluorinated greenhouse gases.
Combination x No. (Inverter) x 7 (Inverter) x 8 (Inverter) x 8 (Inverter) x 8 (Inverter) x 8
Compressor Motor Output x
W x No. 5,300 x 7 (5,300 x 7) + (4,200 x 1) (5,300 x 7) + (4,200 x 1) (5,300 x 7) + (4,200 x 1) 5,300 x 8
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 19,500 20,800 20,800 20,800 20,800
Type Propeller fan Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x
W x No. 900 x 8 900 x 8 900 x 8 900 x 8 900 x 8
Number
Fan Air Flow Rate (High) m /min x No.
3
320 x 4 320 x 4 320 x 4 320 x 4 320 x 4
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8)
Connections
Low Pressure Gas Pipe mm (inch) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8)
for Heat
Recovery High Pressure Gas Pipe mm (inch) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4)
Pipe Liquid Pipe mm (inch) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8)
Connections
for Heat Pump Gas Pipe mm (inch) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8)
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 4 (1,240 x1,690 x 760) x 4 (1,240 x1,690 x 760) x 4 (1,240 x1,690 x 760) x 4 (1,240 x1,690 x 760) x 4
Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 4 (1,280 x 1,825 x 796) x 4 (1,280 x 1,825 x 796) x 4 (1,280 x 1,825 x 796) x 4 (1,280 x 1,825 x 796) x 4
Net Weight kg x No. (310 x 3) + (237 x 1) (310 x 3) + (300 x 1) (310 x 3) + (300 x 1) (310 x 3) + (300 x 1) 310 x 4
Shipping Weight kg x No. (320 x 3) + (250 x 1) (320 x 3) + (312 x 1) (320 x 3) + (312 x 1) (320 x 3) + (312 x 1) 320 x 4
Sound Cooling dB(A) 70.3 70.3 70.4 70.9 71.0
Pressure Level Heating dB(A) 72.2 72.2 72.5 72.7 73.0
Sound Power Cooling dB(A) 100.2 100.4 100.6 100.6 101.0
Level Heating dB(A) 104.2 104.3 104.4 104.6 105.0
mm2 x No.
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
(VCTF-SB)
Refrigerant Name R410A R410A R410A R410A R410A
Precharged Amount
kg 64.5 67.0 67.0 67.0 68.0
in Factory
Refrigerant
t-CO2 eq. 134.6 139.9 139.9 139.9 142.0
Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion
Control
Valve Valve Valve Valve Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 64 64 64 64 64

1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination(160% ~ 200%). The recommended ratio is 130%.

050 / 051
OUTDOOR
UNITS
300m
TOTAL PIPING LENGTH 150m (175m)
- Air cooled VRF Heat pump & Heat Recovery Longest piping length
from ODU ~ IDU (Equivalent)

MULTI V S
- 12.1 ~ 33.6kW (Cooling capacity based)
- Both 1Φ, 220 ~ 240V, 50Hz and 3Φ, 380 ~ 415V, 50Hz
- Side discharge outdoor unit
- Includes the industry’s first single phase Heat Recovery system

300M
TOTAL PIPING LENGTH

between ODU ~ IDU


Height Difference
50m

between IDU ~ IDU


Height Difference
15m
* Only applies to Multi V S with R410A refrigerant

How does it work?


Available in Heat Pump and
Heat Recovery Configurations

Energy savings Energy saving by heat


recovery unit

Compact yet
Combination of Cooling,
powerful VRF Heating and Hot Water Solution
For premium Reliability

residences and INDOOR UNIT

small offices
HYDRO KIT
MULTI V S
Heat Recovery
Convenience * Heat Pump and Recovery are separated models.

052 / 053
OUTDOOR UNIT _ MULTI V S _ KEY FEATURES

ENERGY SAVINGS RELIABILITY

OUTDOOR
UNITS
EER / COP / Part Load Inverter Twin Rotary & Reliable Refrigerant Components
Cost savings with energy efficiency Inverter Scroll Compressor LG technology allows for superior performance and component durability
Heat Pump Adapted High Efficient Compressor according to Capacity
EER (Cooling) COP (Heating) Inverter Twin Rotary Inverter scroll compressor Refrigerant

MULTI V S
(12.1kw ~ 15.5kw) (22.4kw ~ 33.6kw) ❶ Cyclonic oil separator Refrigerant
+Oil
Compressor Efficiency Comparison - Highly reliable and efficient oil separation by
43%

Efficiency
Scroll Compressor centrifuge using cyclonic methods Cyclone
16% 3.90 5.30 Rotary Compressor Centrifuges
3.35 3.71 - High collection efficiency as well as outstanding
Oil
resistance to high temperature and pressure Oil Separator

Conventional MULTI V S HR Conventional MULTI V S HR


(MULTI V S H/P) (MULTI V S H/P) 12.1 19.6 28 kw
* Comparison Based on 15.5kW in cooling mode * Comparison Based on 15.5kW in heating mode * Based on internal test data
(Cooling capacity) ❷ Large Volume Accumulator
- Improved reliability by adopting the large volume accumulator
Heat Recovery Inverter Twin Rotary (38% volume up compared to conventional) Accumulator
Cooling Mode Heating Mode Concentrated Winding Motor -P  revents the liquid refrigerant entering the compressor suction
Oil path area is improved by over 50% by increasing the extra stator cavity. Due to
Cooling EER is 5% higher than Heating COP is 5% higher than -M aximize efficiency by optimal amount of refrigerant
conventional on average. conventional on average. this, caloric value of motor is reduced, improving the cooling function of stator coil.
- Protects compressor breakdown to increase product lifetime
Twin Rotary Rotor

5% 5% 4.39
Upper and lower part rotor offset imbalance in shaft rotor rotation. Vibration and
40% 20%
❸ BLDC Fan Motor

Efficiency (%)
100
3.90 4.18 noise is reduced. Max torque load decreased by 45% compared to single rotor. BLDC
3.71 Motor
Surface Coating - T he BLDC Fan motor is more efficient than a conventional

50
Surface coating of outstanding abrasion resistance property on vane and crank shaft. AC motor, offering an additional 40% energy savings AC
Conventional MULTI V S HR Conventional MULTI V S HR
at low speeds and 20% at high speeds Motor
(MULTI V S H/P) (MULTI V S H/P)
500 1,000
* Comparison Based on 15.5kW in cooling mode * Comparison Based on 15.5kW in heating mode Inverter scroll compressor Motor Speed (RPM)

Best-in-class Compressor Speed

Operation Range (Hz)


150
❹ Double Sub-cool Interchanger
Smart Load Control Applied - Rapid response capability
- Compact core design (Concentrated motor)
120

20 -R eliability is enhanced by minimizing pressure drop due to high


Enhanced comfort and up to 23% energy savings with - Down to 15Hz : Part load efficiency improvement 15 MULTI V S improved reliability with advanced technology :
efficiency spiral structure and 2 times larger size
Conventional
MULTI V load control 6 Bypass Valve - Oil separator  Long pipe is possible (up to* 175m) and high elevation (up to* 50m)
Compressor reliability is maximized with 6 Bypass Valve - Accumulator Reduction of indoor refrigerant noise level
MULTI V S changes indoor discharge air temperature continuously - Prevent compressor damage due to excessively compressed refrigerant more - Sub-cooling * Based on equivalent pipe length Double Sub-cool Interchanger
according to load, to save energy. efficiently than 4 Bypass valve

SLC (Smart Load Control) operation Direct Oil Injection


Startup Operation Real Time Operation ... - Eliminate suction refrigerant gas heat loss through direct oil injection into

Startup After 20 minutes


compression chamber (efficiency increases)
- Increased reliability with regulated oil supply Smart Control Corrosion Resistance Proven by Certified Tests
Pressure control applied for smart, quick and precise LG Corrosion Resistance solution passed ISO 21207 accelerated
Startup Operation Scroll Profile
response to user's temperature request corrosion test conducted by an independent test organization and the
-T  he enhanced reliability by Increased reliability with regulated oil supply.
Basic Operation Smart Load Control - Efficiency increases by expanding 96% Bypass area and 17% improved volume ratio by non- result has been certified by prestigious global certification organization,
Indoor uniform scroll thickness Temperature + Pressure Control TUV.
Discharge Air
Temperature
Senses and controls pressure directly
Certified protection
Power
Input
Optimal Heat Exchanger using pressure sensor for faster and more
exact response to load variation.
Maximize Efficiency according to different Heat Exchanger
Indoor air discharge temperature
Until 20 minutes after startup operation path by cooling and heating High Pressure Low Pressure
- Energy efficiency increased by 3-step Smart Load Control during startup phase Sensor Sensor
- Discharge air temperature adjusted according to outdoor and indoor temperature
Variable Heat Exchanger Circuit intelligently selects the optimal
- Comfort level in cooling / heating operations ensured Quick Operating Response Outlet Temp. (°C)
path for both heating and cooling operations. With this smart path
Max. 10% Energy saving selection technology, an average of 6% increase in the efficiency of
Desired temperature can be 27

reached up to 14% faster in 14%


both operations has been achieved. The paths number and circuit Quicker
Real Time Operation cooling mode with pressure ※ Verification of corrosion resistance performance
velocity are adjusted to match temperatures and operation modes in 12
- Declared by TUV Rheinland
Basic Operation Smart Load Control control, allowing more accurate 14%
order to maximize efficiency instead of compromising efficiency for - Test Method B of ISO21207
control of indoor environment for - Test condition: Salt contaminated condition
3°C 10°C each operation when the number and direction of paths are fixed 2min Time + s evere industrial/traffic
Refrigerant Refrigerant maximized comfort. Pressure +Temperature Control
independently of temperature operation mode. environment(NO2/SO2)
20°C 20°C Temperature Control
* Specifications may vary for each model.

3°C 3°C
Refrigerant Refrigerant Enhanced Coating Layers
Fixed heat
35°C 35°C exchanger circuit The black coating with enhanced epoxy resin is applied for strong
Cooling Heating
protection from various corrosive external conditions such as salt
Fixed refrigerant temperature Variable refrigerant temperature Efficiency performance Efficiency up due to Fin shape Corrosion Resistance Black Fin contamination and air pollution. Moreover, the hydrophilic film keeps
Efficiency
Improved heat exchanger efficiency of up to 28% Strong Durability against high salinity and heavily polluted air water from accumulating on the heat exchanger’s fin, minimizing
Max. 13% Energy saving
Conventional Wide Louver Plus Fin moisture buildup and eventually making it even more corrosion resistant.
How to set up:: By dip switch in outdoor unit (Referred to Product Data Book) Factory default setting is Off. Heating Ocean Black Fin ensures continued operation of MULTI V S in highly
* ESEER (European seasonal energy efficiency Ratio) conditions based on 15.5kw unit Cooling 100% Cooling 128% corrosive environments like salt concentration in coastal towns or severe air Hydrophilic film (Water flow)
- Outdoor temperature condition :
The Hydrophilic coating minimizes moisture buildup on the fin.
EER 100% / 75% / 50% / 25% = 35℃ (DB) / 30℃ (DB) / 25℃ (DB) / 20℃ (DB) Cooling pollution in industrial cities keeps. This improvement in durability prolongs the
- Indoor temperature condition : 27°C (DB) / 19°C (WB) Heating 100% Heating 123%
product’s lifespan and lowers both the operational and maintenance costs. Acryl + Epoxy + Melamine resin (Corrosion resistant)
* Dual sensing (Temparature & humidity) smart load control is possible with Remote controller
Previous Design Number of The Black coating provides strong protection from corrosion.
PTEMTB100 (White) /PREMTBB10 (Black) (Fixed) circuit
Aluminum fin

054 / 055
OUTDOOR UNIT _ MULTI V S _ KEY FEATURES OUTDOOR UNIT _ MULTI V S _ TECHNICAL DATA

IMPROVED USER CONVENIENCE Nomenclature [Unit : mm] Symbols

OUTDOOR
A 165 620 Piping Direction

UNITS
A Datum Iine
ARU N 100 L S S 0 Piping

Sufficient Piping Length Fan Technology and RPM Control Direction

390
360
Serial number

Increased piping length allows for flexible design External static pressure control for outdoor unit fan to adapt Model Type
S : Standard 4 holes for Anchor Bolts (M10)
and installation more flexibly to various installation conditions of outdoor unit L : Compact C A
330 (34) 26 950
Air Discharge Type C
(7) 81 26 97 82 244
S : Side Discharge
MULTI V S inverter technology and sub cooling control circuit For enhanced efficiency, new axial fan boasts higher air volume, increased

MULTI V S
Electrical Ratings 5 5
technology allows greater piping length and outstanding elevation static pressure and decreased noise. L : 3Ø, 380-415V, 50Hz
5 5
differences. A cooling system can be implemented more flexibly in a G : 1Ø, 220-240V, 50Hz

834
Total Cooling Capacity in Horse Power(HP) unit
shop, office and even high-rise building, reducing the designer’s work

660
627
Fan Technology EX) 8HP → '080', 10HP → '100'
3

141 466
476
time and providing more efficient design. Combination of Inverter Type and Cooling Only
The new axial fan has a mogul trailing edge, narrow hub blade and reverse hub,

24
or Heat Pump B B B

83
this provides a high efficiency, low noise, wide fan, as well as improving the air N : Inverter and H/P, V : Inverter and C/O 51 148
1 64
2 4
Piping Capabilities flow rate. MULTI V System Outdoor Unit using R410A 416
40

111
291
276
Reverse
300m Mogul hub
Total piping length trailing edge Outdoor Unit Function 5-1.D. Ø 20 holes for drain connection 91
250 696
Category Functions MULTI V S
50m 526mm Variable Path of Outdoor Unit HEX -
A

ODU ~ IDU
Height Narrow HiPORTM (High Pressure Oil Return) -
150m difference hub blade Key Refrigerant
Humidity Sensor ARUB060GSS4 only
(1Ø) 4 / 5HP (1Ø) 5 / 6HP Components
(175m) (3Ø) 4 / 5 / 6 / 8HP Corrosion Resistance Black Fin ○
Longest
pipe length
15m Oil Sensor -
IDU ~ IDU Super cannon fan increases the air volume in 50 CMM and the noise level is
(Equivalent) Dual Sensing ARUB060GSS4 only
Height decreased by 4dB(A). 3D View
Low Noise Operation ○
difference
Hgih Static Mode of Outdoor Unit Fan ○
Grooved Piping
[Unit : mm] 620
suction surface Partial Defrosting - Direction

Auto Dust Removal of Outdoor Unit

14
Special Function -

390
360
(Fan reverse rotation)
Indoor Cooling Comfort Mode Based

Tip vortex Outdoor Temperature C A
suppressor Smart Load Control (SLC) 4 holes for Anchor Bolts (M10)
(Changing indoor discharge air ○
temperature according to load) C
4 Way Piping Super Canon Fan 330 26
A 950
(3Ø) 10 / 12HP Outdoor Unit Control Refer to Humidity ARUB060GSS4 only 90
- Free design and installation by 4 way piping. C
Defrost / Deicing ○
Fan RPM control High Pressure Switch ○
Flow of air is straight due to fan shroud and Fan RPM control even in high-rise Phase Protection ○
5

1380
building. Basic Function Restart Delay (3-minutes) ○
Self Diagnosis ○ 2

606
Soft Start ○

80
Fan RPM Test Run Function - 80
52
control
+ + 25 26

52
(Fan Max. AC Ez (Simple Controller) PQCSZ250S0 B 1 6 96 B 96
7
RPM Up)
AC Ez Touch PACEZA000 695
416
Fan Shroud AC Smart IV PACS4B000 250
91
164
Central Controller AC Smart 5 PACS5A000 40
* E.S.P : External Static Pressure
• Straight air flow

111
ACP (Advanced Control Platform) IV PACP4B000

291
276
Low Noise Operation - New shroud adopted
- Performs high static pressure ACP (Advanced Control Platform) 5 PACP5A000 5-1.D. Ø
Decreased noise during operation with low noise functionalitiy AC Manager 5 PACM5A000
20 holes for drain connection

ACP Lonworks PLNWKB000 75


BNU (Building A
At night mode, noise reduced maximum 14% compared to normal mode. Network Unit) ACP BACnet PQNFB17C0
Upgraded Fault Detection and Diagnosis

60
44
IO Module (ODU Dry Contact) PVDSMN000
Capacity Easy and convenient maintenance with self-diagnosis PDI (Power Standard PPWRDB000
42
91

Load Distribution 4
The inclusion of FDD elements - Auto start-up, auto refrigerant check, Indicator) Premium PQNUD1S40 3
black box functionality, simultaneous evaluation, and auto refrigerant Cool / Heat Selector PRDSBM

606

536
557
collection, provides the optimal solution for user reliability and ease Cycle Monitoring LGMV PRCTIL0
Sound Level
Night

85
58
of maintenance. Device Mobile LGMV PLGMVW100
Mode Start Mode End 24

52
○ B 25 8
56 Step 1
(Logical operation) 3D View 81

53 Step 2
- Auto commissioning Mode Refrigerant Charging Kit Piping connection port
Not applied to 94
50 Step 3
- Auto Refrigerant Collection Additional kit ARUB060GSS4
8:00 12:00 16:00 20:00 0:00 4:00 8:00 12:00 16:00
- Auto evaluation of refrigerant amount Low Ambient Kit - Note No. Part Name Description
Time
and charging FDD Variable Water Flow Valve Control Kit -
1. Unit should be installed in compliance with the 1
2
Air Outlet
Power and communication cable Hole
-
-
MICOM installation manual in the product box.
Max. - Able to access LGMV (LG Monitoring 2. Unit should be grounded in accordance with the
3 Gas Pipe Connection Welding joint
4 Liquid Pipe Connection Welding joint
58 8dB(A) View) by smartphone ※ ○ : Applied, - : Not Applied local regulation or applicable national codes. 5 Handle -
3. All electrical components and materials to be 6 Pipe routing hole (front) -
- Black box function 7 Pipe routing hole (side) -
supplied from the site must comply with the local
8 Pipe routing hole (back) -
- Piping & wiring error check-up regulations or international codes.
50 4. Electrical characteristics chapter should be
* Normal mode noise level (28kw) : 58dB(A) considered for electrical work and design.
50dB(A) * Night 3 step noise level (28kw) : Especially the power cable and circuit breaker
56dB(A),53dB(A), 50dB(A)
should be selected in accordance with that.
* Sound pressure tested by following conditions :
Day Night 1m distance / 1.5m height

056 / 057
OUTDOOR UNIT _ MULTI V S _ TECHNICAL DATA OUTDOOR UNIT _ MULTI V S _ SPECIFICATION

Heat Pump
MULTI V S HEAT PUMP

OUTDOOR
UNITS
Cooling 45°C Heating 20°C
43°C 18°C
40°C 15°C
ARUN040GSS0 / ARUN050GSL0

Outdoor Temperature (°C WB)

Range for warming up operation


Outdoor Temperature (°C DB)

Range for continuous operation


Range for continuous operation
35°C
10°C

Range for pull down operation


30°C
5°C
25°C

MULTI V S
20°C 0°C

15°C -5°C

10°C
-10°C
LG participates in the ECP programme for EUROVENT
5°C
-15°C VRF program. Check ongoing validity of certification
0°C : www.eurovent-certification.com
-20°C
-5°C
-10°C -25°C
10°C 14°C 15°C 20°C 25°C 27°C 30°C 10°C 15°C 20°C 25°C 27°C 30°C
HP 4 5
Indoor Temperature (°C WB) Indoor Temperature (°C DB)
Model Name ARUN040GSS0 ARUN050GSL0
Cooling (Rated) kW 12.1 14.0
Heat Recovery Capacity
Heating (Rated) kW 12.5 15.0
Cooling (Rated) kW 3.78 4.38
Input
Cooling 50°C
Heating Heating (Rated) kW 2.10 2.65
48°C
20°C EER 3.20 3.20
45°C
18°C SEER 5.98 6.60
40°C
15°C

Range for warming up operation


COP Rated Capacity 5.9 5.7
Range for continuous operation

Range for pull down operation

continuous operation
35°C

Outdoor Temperature (°C WB)


SCOP 5.15 4.96
Outdoor Temperature (°C DB)

10°C
30°C

Range for
5°C
Color (General) Warm Gray Warm Gray
25°C Exterior
RAL Code (Classic) RAL 7044 RAL 7044
0°C
20°C Heat
Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Exchanger
15°C -5°C
Type BLDC Inverter Twin Rotary BLDC Inverter Twin Rotary
10°C
-10°C Combination x No. (Inverter) x 1 (Inverter) x 1
5°C
-15°C Compressor Motor Output x Number W x No. 4,000 x 1 4,000 x 1
0°C Oil Type FVC68D (PVE) FVC68D (PVE)
-20°C
-5°C Oil Charge cc 1,300 1,300
-10°C -25°C Type Axial Flow Fan Axial Flow Fan
10°C 15°C 20°C 25°C 27°C 30°C
-15°C Motor Output x Number W x No. 124 x 1 124 x 1
10°C 14°C 15°C 20°C 25°C 27°C 30°C Indoor Temperature (°C DB) Fan Air Flow Rate (High) m3/min x No. 60 x 1 60 x 1
Indoor Temperature (°C WB) Drive DC INVERTER DC INVERTER
Discharge Side / Top Side Side
Pipe Liquid Pipe mm (inch) Ø 9.52 (3/8) Ø 9.52 (3/8)
Simultaneous Cooling Simultaneous Heating
Connctions Gas Pipe mm (inch) Ø 15.88 (5/8) Ø 15.88 (5/8)
30°C 20°C
Dimensions (W x H x D) mm x No. (950 x 834 x 330) x 1 (950 x 834 x 330) x 1
27°C
25°C
16°C Dimensions (W x H x D) - Shipping mm x No. (1,065 x 918 x 461) x 1 (1,065 x 918 x 461) x 1
15°C
Net Weight kg x No. 70 x 1 73 x 1
Range for continuous operation

Outdoor Temperature (°C WB)


Range for pull down operation
Outdoor Temperature (°C DB)

20°C
Range for continuous operation
Range for pull down operation

Shipping Weight kg x No. 77 x 1 81 x 1


10°C
15°C Sound Cooling dB(A) 50.0 52.0
Pressure
10°C Level Heating dB(A) 52.0 58.0
5°C
5°C Sound Cooling dB(A) 72.0 72.0
Power Level Heating dB(A) 76.0 75.0
0°C 0°C
mm2 x No.
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
(VCTF-SB)
-5°C
-5°C Refrigerant Name R410A R410A
-10°C Precharged Amount in
kg 1.8 2.4
Refrigerant factory
-15°C -10°C
t-CO2 eq. 3.8 5.0
10°C 14°C 15°C 20°C 25°C 27°C 30°C 10°C 15°C 20°C 25°C 30°C
Control Electronic Expansion Valve Electronic Expansion Valve
Indoor Temperature (°C WB) Indoor Temperature (°C DB)
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50
Note Number of Maximum Connectable Indoor Units 8 8*
1. These figures assume the following operating conditions : Equivalent piping length : 7.5m
Level difference : 0m
2. Range of pull down operation : If the relative humidity is too high, cooling capacity can be decreased by the sensible

Position of Sound Level Measuring


* : In case of ARUN050GSL0, maximum combination ratio is 130%.
Note
Note
1. Eurovent Test Condition : Type of indoor unit connected is only Ceiling Concealed Duct.
These figures assume the following operating conditions:
- Refer to EUROVENT certification regulation for more detail test conditions.
Equivalent piping length : 7.5m
- Refer to EUROVENT website for test values connected Ceiling Cassette type indoors.
Level difference : 0m
2. Performances are based on the following conditions :
- Cooling Temperature : Indoor 27°C (80.6°F) DB / 19°C (66.2°F) WB / Outdoor 35°C (95°F) DB / 24°C (75.2°F) WB
1.5m

- Heating Temperature : Indoor 20°C (68°F) DB / 15°C (59°F) WB / Outdoor 7°C (44.6°F) DB / 6°C (42.8°F) WB
3. The maximum combination ratio is 160%. (the maximum combination ratio of ARUN050GSL0 is 130%.)
1m 4. Wiring cable size must comply with the applicable local and national codes.
5. Due to our policy of innovation some specifications may be changed without notification.
6. S
 ound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is
measured on the rated condition in the reverberation rooms by ISO 3741 standard. Therefore, these values can be increased
owing to ambient conditions during operation.
7. Power factor could vary less than ±1% according to the operating conditions.
8. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)

058 / 059
OUTDOOR UNIT _ MULTI V S _ SPECIFICATION

MULTI V S HEAT PUMP MULTI V S HEAT PUMP

OUTDOOR
UNITS
ARUN050GSS0 / ARUN060GSS0 ARUN040LSS0 / ARUN050LSS0
ARUN060LSS0

MULTI V S
LG participates in the ECP programme for EUROVENT LG participates in the ECP programme for EUROVENT
VRF program. Check ongoing validity of certification VRF program. Check ongoing validity of certification
: www.eurovent-certification.com : www.eurovent-certification.com

HP 5 6 HP 4 5 6
Model Name ARUN050GSS0 ARUN060GSS0 Model Name ARUN040LSS0 ARUN050LSS0 ARUN060LSS0
Cooling (Rated) kW 14.0 15.5 Cooling (Rated) kW 12.1 14.0 15.5
Capacity Capacity
Heating (Rated) kW 16.0 18.0 Heating (Rated) kW 12.5 16.0 18.0
Cooling (Rated) kW 3.33 3.97 Cooling (Rated) kW 2.37 3.33 3.97
Input Input
Heating (Rated) kW 2.77 3.40 Heating (Rated) kW 1.93 2.77 3.40
EER 4.20 3.90 EER 5.10 4.20 3.90
SEER 6.56 6.65 SEER 6.46 6.56 6.65
COP Rated Capacity 5.77 5.30 COP Rated Capacity 6.49 5.77 5.30
SCOP 5.23 5.19 SCOP 5.02 5.23 5.19
Color (General) Warm Gray Warm Gray Color (General) Warm Gray Warm Gray Warm Gray
Exterior Exterior
RAL Code (Classic) RAL 7044 RAL 7044 RAL Code (Classic) RAL 7044 RAL 7044 RAL 7044
Heat Heat
Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Exchanger Exchanger
Type BLDC Inverter Twin Rotary BLDC Inverter Twin Rotary Type BLDC Inverter Twin Rotary BLDC Inverter Twin Rotary BLDC Inverter Twin Rotary
Combination x No. (Inverter) x 1 (Inverter) x 1 Combination x No. (Inverter) x 1 (Inverter) x 1 (Inverter) x 1
Compressor Motor Output x Number W x No. 4,000 x 1 4,000 x 1 Compressor Motor Output x Number W x No. 4,000 x 1 4,000 x 1 4,000 x 1
Oil Type FVC68D (PVE) FVC68D (PVE) Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 1,300 1,300 Oil Charge cc 1,300 1,300 1,300
Type Axial Flow Fan Axial Flow Fan Type Axial Flow Fan Axial Flow Fan Axial Flow Fan
Motor Output x Number W x No. 124 x 2 124 x 2 Motor Output x Number W x No. 124 x 2 124 x 2 124 x 2
Fan Air Flow Rate (High) m3/min x No. 110 x 1 110 x 1 Fan Air Flow Rate (High) m3/min x No. 110 x 1 110 x 1 110 x 1
Drive DC INVERTER DC INVERTER Drive DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top Side Side Discharge Side / Top Side Side Side
Pipe Liquid Pipe mm (inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Pipe Liquid Pipe mm (inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 9.52 (3/8)
Connctions Gas Pipe mm (inch) Ø 15.88 (5/8) Ø 19.05 (3/4) Connctions Gas Pipe mm (inch) Ø 15.88 (5/8) Ø 15.88 (5/8) Ø 19.05 (3/4)
Dimensions (W x H x D) mm x No. (950 x 1,380 x 330) x 1 (950 x 1,380 x 330) x 1 Dimensions (W x H x D) mm x No. (950 x 1,380 x 330) x 1 (950 x 1,380 x 330) x 1 (950 x 1,380 x 330) x 1
Dimensions (W x H x D) - Shipping mm x No. (1,140 x 1,462 x 461) x 1 (1,140 x 1,462 x 461) x 1 Dimensions (W x H x D) - Shipping mm x No. (1,140 x 1,462 x 461) x 1 (1,140 x 1,462 x 461) x 1 (1,140 x 1,462 x 461) x 1
Net Weight kg x No. 94 x 1 94 x 1 Net Weight kg x No. 96 x 1 96 x 1 96 x 1
Shipping Weight kg x No. 106 x 1 106 x 1 Shipping Weight kg x No. 108 x 1 106 x 1 106 x 1
Sound Cooling dB(A) 51.0 52.0 Sound Cooling dB(A) 50.0 51.0 52.0
Pressure Pressure
Level Heating dB(A) 53.0 54.0 Level Heating dB(A) 52.0 53.0 54.0
Sound Cooling dB(A) 72.0 72.0 Sound Cooling dB(A) 72.0 72.0 72.0
Power Level Heating dB(A) 76.0 77.0 Power Level Heating dB(A) 76.0 76.0 77.0
mm2 x No. mm2 x No.
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
(VCTF-SB) (VCTF-SB)
Refrigerant Name R410A R410A Refrigerant Name R410A R410A R410A
Precharged Amount in Precharged Amount in
kg 3.0 3.0 kg 3.0 3.0 3.0
Refrigerant factory Refrigerant factory
t-CO2 eq. 6.3 6.3 t-CO2 eq. 6.3 6.3 6.3
Control Electronic Expansion Valve Electronic Expansion Valve Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 10 13 Number of Maximum Connectable Indoor Units 8 10 13

* : In case of ARUN050GSL0, maximum combination ratio is 130%. * : In case of ARUN050GSL0, maximum combination ratio is 130%.
Note Note
1. Eurovent Test Condition : Type of indoor unit connected is only Ceiling Concealed Duct. 1. Eurovent Test Condition : Type of indoor unit connected is only Ceiling Concealed Duct.
- Refer to EUROVENT certification regulation for more detail test conditions. - Refer to EUROVENT certification regulation for more detail test conditions.
- Refer to EUROVENT website for test values connected Ceiling Cassette type indoors. - Refer to EUROVENT website for test values connected Ceiling Cassette type indoors.
2. Performances are based on the following conditions : 2. Performances are based on the following conditions :
- Cooling Temperature : Indoor 27°C (80.6°F) DB / 19°C (66.2°F) WB / Outdoor 35°C (95°F) DB / 24°C (75.2°F) WB - Cooling Temperature : Indoor 27°C (80.6°F) DB / 19°C (66.2°F) WB / Outdoor 35°C (95°F) DB / 24°C (75.2°F) WB
- Heating Temperature : Indoor 20°C (68°F) DB / 15°C (59°F) WB / Outdoor 7°C (44.6°F) DB / 6°C (42.8°F) WB - Heating Temperature : Indoor 20°C (68°F) DB / 15°C (59°F) WB / Outdoor 7°C (44.6°F) DB / 6°C (42.8°F) WB
3. The maximum combination ratio is 160%. (the maximum combination ratio of ARUN050GSL0 is 130%.) 3. The maximum combination ratio is 160%. (the maximum combination ratio of ARUN050GSL0 is 130%.)
4. Wiring cable size must comply with the applicable local and national codes. 4. Wiring cable size must comply with the applicable local and national codes.
5. Due to our policy of innovation some specifications may be changed without notification. 5. Due to our policy of innovation some specifications may be changed without notification.
6. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is 6. S
 ound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is
measured on the rated condition in the reverberation rooms by ISO 3741 standard. Therefore, these values can be increased measured on the rated condition in the reverberation rooms by ISO 3741 standard. Therefore, these values can be increased
owing to ambient conditions during operation. owing to ambient conditions during operation.
7. Power factor could vary less than ±1% according to the operating conditions. 7. Power factor could vary less than ±1% according to the operating conditions.
8. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5) 8. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)

060 / 061
OUTDOOR UNIT _ MULTI V S _ SPECIFICATION

MULTI V S HEAT PUMP MULTI V S HEAT RECOVERY

OUTDOOR
UNITS
ARUN080LSS0 / ARUN100LSS0 ARUB060GSS4
ARUN120LSS0

MULTI V S
LG participates in the ECP programme for EUROVENT LG participates in the ECP programme for EUROVENT
VRF program. Check ongoing validity of certification VRF program. Check ongoing validity of certification
: www.eurovent-certification.com : www.eurovent-certification.com

HP 8 10 12 HP 6
Model Name ARUN080LSS0 ARUN100LSS0 ARUN120LSS0 Model Name ARUB060GSS4
Cooling (Rated) kW 22.4 28.0 33.6 Cooling (Rated) kW 15.5
Capacity Capacity
Heating (Rated) kW 24.5 30.6 36.7 Heating (Rated) kW 18.0
Cooling (Rated) kW 8.30 8.75 14.00 Cooling (Rated) kW 3.97
Input Input
Heating (Rated) kW 6.62 8.12 7.46 Heating (Rated) kW 4.10
EER 2.70 3.20 2.40 EER 3.90
SEER 6.03 6.59 5.72 SEER 6.84
COP Rated Capacity 3.70 3.77 4.92 COP Rated Capacity 4.39
SCOP 4.33 4.17 3.86 SCOP 4.38
Color (General) Warm Gray Warm Gray Warm Gray Color Warm Gray
Exterior Exterior
RAL Code (Classic), General RAL 7044 RAL 7044 RAL 7044 RAL Code (Classic) RAL 7044
Heat Heat
Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Type Wide Louver Plus
Exchanger Exchanger
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Type Hermetically Sealed Scroll
Combination x No. (Inverter) x 1 (Inverter) x 1 (Inverter) x 1 Combination x No. (Inverter) x 1
Compressor Motor Output x Number W x No. 4,200 x 1 5,300 x 1 5,300 x 1 Compressor Motor Output x Number W x No. 4,200 x 1
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) Oil Type FVC68D (PVE)
Oil Charge cc 2,400 2,600 3,400 Oil Charge cc 1,700
Type Propeller fan Propeller fan Propeller fan Type Axial Flow Fan
Motor Output x Number W x No. 124 x 2 250 x 2 250 x 2 Motor Output x Number W x No. 124 x 2
Fan Air Flow Rate (High) m3/min x No. 140 x 1 190 x 1 190 x 1 m3/min x
Fan Air Flow Rate (High) 110 x 1
No.
Drive DC INVERTER DC INVERTER DC INVERTER
Drive DC INVERTER
Discharge Side / Top Side Side Side
Discharge Side / Top Side
Pipe Liquid Pipe mm (inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 12.7 (1/2)
Pipe Liquid Pipe mm (inch) Ø 9.52 (3/8)
Connctions Gas Pipe mm (inch) Ø 19.05 (3/4) Ø 22.2 (7/8) Ø 28.58 (1-1/8)
Connctions Low Pressure Gas Pipe mm (inch) Ø 19.05 (3/4)
Dimensions (W x H x D) mm x No. (950 x 1,380 x 330) x 1 (1,090 x 1,625 x 380) x 1 (1,090 x 1,625 x 380) x 1 #1 High Pressure Gas Pipe mm (inch) Ø 15.88 (5/8)
Dimensions (W x H x D) - Shipping mm x No. (1,140 x 1,462 x 461) x 1 (1,215 x 1,795 x 500) x 1 (1,215 x 1,795 x 500) x 1
Dimensions (W x H x D) mm x No. (950 x 1,380 x 330) x 1
Net Weight kg x No. 115 x 1 144 x 1 157 x 1
Dimensions (W x H x D) - shipping mm x No. (1,140 x 1,549 x 466) x 1
Shipping Weight kg x No. 127 x 1 160 x 1 173 x 1
Net Weight kg x No. 118 x 1
Sound Cooling dB(A) 57.0 58.0 60.0
Shipping Weight kg x No. 132 x 1
Pressure Level Heating dB(A) 57.0 58.0 60.0
Sound Cooling dB(A) 56.0
Sound Cooling dB(A) 81.0 80.0 81.0 Pressure Level Heating dB(A) 58.0
Power Level Heating dB(A) 84.0 84.0 85.0
Sound Cooling dB(A) 76.0
mm2 x No.
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Power Level Heating dB(A) 78.0
(VCTF-SB)
Refrigerant Name R410A R410A R410A mm2 x No.
Communication Cable 1.0 ~ 1.5 x 2C
Precharged Amount in (VCTF-SB)
kg 3.5 4.5 6.0 Refrigerant Name R410A
Refrigerant factory
t-CO2 eq. 7.3 9.4 12.5 Precharged Amount in
kg 3.5
Refrigerant factory
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
t-CO2 eq. 7.3
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Control Electronic Expansion Valve
Number of Maximum Connectable Indoor Units 13 16 20
Power Supply Ø, V, Hz 1, 220-240, 50
Number of Maximum Connectable Indoor Units 13

* : In case of ARUN050GSL0, maximum combination ratio is 130%. * : In case of ARUN050GSL0, maximum combination ratio is 130%.
Note Note
1. Eurovent Test Condition : Type of indoor unit connected is only Ceiling Concealed Duct. 1. Eurovent Test Condition : Type of indoor unit connected is only Ceiling Concealed Duct.
- Refer to EUROVENT certification regulation for more detail test conditions. - Refer to EUROVENT certification regulation for more detail test conditions.
- Refer to EUROVENT website for test values connected Ceiling Cassette type indoors. - Refer to EUROVENT website for test values connected Ceiling Cassette type indoors.
2. Performances are based on the following conditions : 2. Performances are based on the following conditions :
- Cooling Temperature : Indoor 27°C (80.6°F) DB / 19°C (66.2°F) WB / Outdoor 35°C (95°F) DB / 24°C (75.2°F) WB - Cooling Temperature : Indoor 27°C (80.6°F) DB / 19°C (66.2°F) WB / Outdoor 35°C (95°F) DB / 24°C (75.2°F) WB
- Heating Temperature : Indoor 20°C (68°F) DB / 15°C (59°F) WB / Outdoor 7°C (44.6°F) DB / 6°C (42.8°F) WB - Heating Temperature : Indoor 20°C (68°F) DB / 15°C (59°F) WB / Outdoor 7°C (44.6°F) DB / 6°C (42.8°F) WB
3. The maximum combination ratio is 160%. (the maximum combination ratio of ARUN050GSL0 is 130%.) 3. The maximum combination ratio is 160%. (the maximum combination ratio of ARUN050GSL0 is 130%.)
4. Wiring cable size must comply with the applicable local and national codes. 4. Wiring cable size must comply with the applicable local and national codes.
5. Due to our policy of innovation some specifications may be changed without notification. 5. Due to our policy of innovation some specifications may be changed without notification.
6. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is 6. S
 ound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is
measured on the rated condition in the reverberation rooms by ISO 3741 standard. Therefore, these values can be increased measured on the rated condition in the reverberation rooms by ISO 3741 standard. Therefore, these values can be increased
owing to ambient conditions during operation. owing to ambient conditions during operation.
7. Power factor could vary less than ±1% according to the operating conditions. 7. Power factor could vary less than ±1% according to the operating conditions.
8. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5) 8. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)

062 / 063
OUTDOOR UNIT _ MULTI V S _ KEY FEATURES

MULTI V S MULTI V S

OUTDOOR
UNITS
Energy Savings Energy Savings
Energy consumption can be reduced as indoor heat is absorbed and transfered to hot water supply. Energy consumption can be reduced as indoor heat is absorbed and transfered to hot water supply.

MULTI V S
Conventional MULTI V S Heat Recovery with HYDRO KIT
Absorbed heat is released to outdoor air. Absorbed heat from indoor space is used for making hot water.

Heat Heat Transfer Heat Transfer


Released

HR Unit

Heat Heat
Absorption Absorption

Conventional
Heat Recovery

Hot water Hot water

Boiler Domestic HYDRO KIT Domestic


(Gas or Electric) Hot Water Tank Hot Water Supply Cooling Hot Water Tank Hot Water Supply Cooling

064 / 065
OUTDOOR UNIT _ MULTI V S R32 _ KEY FEATURES

INNOVATIVE TECHNOLOGIES

OUTDOOR
UNITS
R1 Compressor is one that combines high-efficiency, low sound characteristics of the scroll and the simple compressing
- Air cooled VRF Heat pump
structure of the rotary compressor. This technology enables a highly efficient compact model.
- 12.1 ~ 15.5kW (Cooling capacity based)
- Both 1Φ, 220 ~ 240V, 50Hz and 3Φ, 380 ~ 415V, 50Hz

MULTI V S R32
Centrifugal oil return
- Side discharge outdoor unit
& Oil separating guide
for oil discharge reduction

WHY R32 REFRIGERANT? WHY MULTI V S R32?


Low global warming potential (GWP) Higher Efficiency Extended Operation Range
(max 150Hz)
- Higher Cooling Performance
What is GWP? LG Multi V S achieved high efficiency through technology of biomimetic fan and revolutionary
scroll compressor
Global warming potential is a measure that allows for an accurate comparison of the
environmental impact of different gases. GWP measures how much energy the emissions
of 1 ton of a gas will absorb over a given period of time, relative to the emissions of 1 ton
EER 3.65
VS
EER 4.20 15%
of carbon dioxide (CO2). COP 4.10 EER 5.15 25%
Shaft-through Structure
& Support both ends of shaft
- Solid compressor operation assuring higher durability

Superior to
competitor’s
R410A R134a R32 N2O CH4
2,088 molecules 1,430 molecules 675 molecules 298 molecules 25 molecules
※ The values based on 5HP model Bottom Compression - Lower Noise & Vibration (*max 4dB(A) ↓)
& Simple Structure - Less Weight (*20% ↓)
Global Trend and EU Regulation for F-Gas - Superior Reliability
HFC* Phase Down 79% by 2030 Compact Size & Light Weight
100 93 Its compact size and light weight make it easy to install and optimize space. (5/6HP)
% Phase down of HFC Consumption

90
80 79%
70
60
63
HFCs refrigerants 23% Conventional Compressor
50 45 should be reduced Light Weight
40 by 79% by 2030 546mm Scroll : High efficiency / Low sound Revolutionary Scroll : H
 igh efficiency / Stable
30
21 compared to 2013. (Continuous compression, but complex structure) & Simple Structure
20
10 * Hydrofluorocarbon : One of
the alternative freon gas that
Hybrid Scroll Shape
2014 2016 2018 2020 2022 2024 2026 2028 2030 2032 does not harm the Earth's
compression (LG patent)*
Year ozone layer
Previous New part(upper) * Patent registration
number (S.Korea :
10-1059880, USA :
Cost Savings with R32 Less Refrigerant Charge
RE46106)

Motor compression part


Higher Efficiency Less Refrigerant Charge LG reduced refrigerant charge by applying environment-friendly refrigerant R32.
Savings on cost of energy Savings on cost of injecting & Motor
Total amount : 5.6 kg sub-frame
consumption. replacing refrigerant . Factory Charging : 3 kg Total amount : 4.3 kg 23% Oil
Compression parts
Factory Charging : 2 kg
(upper → lower)
20% Scroll penetrated by shaft
→ remove tilting moment

Simple structure :
Previous New Rotary : Simple structure without sub-frame
※ IDU (Wall Mounted Unit) : 5 kBtu/h, 8 EA
※ This result can be different depending on actual environment (Compression per 1 rotation ) Oil feeding structure better
Reduced Equipment Sizes Reduced Refrigerant Volume than previous scroll
Savings on product purcahse and Savings on refrigerant purchase Corrosion Resistance Black Fin Oil
labor cost for installation and and recycling costs
The black coating with enhanced epoxy resin is applied for strong protection from various
maintenance corrosive external conditions
Motor
Extended operation (Max. 150Hz)
compression
Hydrophilic film (Water flow) part (lower) Low noise & Vibration (Max. 4dB(A)↓)
The Hydrophilic coating minimizes moisture buildup on the fin.
Oil Less weight (20%↓)
Acryl + Epoxy + Melamine resin (Corrosion resistant) compression part
The Black coating provides strong protection from corrosion.

Aluminum fin Compact model


(Size 40%↓, Weight 25%↓)

066 / 067
OUTDOOR UNIT _ MULTI V S R32 _ SPECIFICATION

MULTI V S HEAT PUMP R32 MULTI V S HEAT PUMP R32

OUTDOOR
UNITS
ZRUN040GSS0 / ZRUN050GSS0 ZRUN040LSS0 / ZRUN050LSS0
ZRUN060GSS0 ZRUN060LSS0

MULTI V S R32
Available from June 2020

LG participates in the ECP programme for EUROVENT LG participates in the ECP programme for EUROVENT
VRF program. Check ongoing validity of certification VRF program. Check ongoing validity of certification
: www.eurovent-certification.com : www.eurovent-certification.com

HP 4 5 6 HP 4 5 6
Model Name ZRUN040GSS0 ZRUN050GSS0 ZRUN060GSS0 Model Name ZRUN040LSS0 ZRUN050LSS0 ZRUN060LSS0
Cooling (Rated) kW 12.1 14.0 15.5 Cooling (Rated) kW 12.1 14.0 15.5
Capacity Heating (Rated) kW 12.1 14.0 15.5 Capacity Heating (Rated) kW 12.1 14.0 15.5
Heating (Max) kW 14.2 16.0 18.0 Heating (Max) kW 14.2 16.0 18.0
Cooling (Rated) kW 3.43 3.33 3.97 Cooling (Rated) kW 3.43 3.33 3.97
Input Heating (Rated) kW 2.30 2.72 3.23 Input Heating (Rated) kW 2.30 2.72 3.23
Heating (Max) kW 2.93 3.48 4.29 Heating (Max) kW 2.93 3.48 4.29
EER (Rated) 3.53 4.20 3.90 EER (Rated) 3.53 4.20 3.90
SEER 8.10 8.70 8.50 SEER 8.10 8.70 8.50
COP (Rated) 5.26 5.15 4.80 COP (Rated) 5.26 5.15 4.80
COP (Max) 4.84 4.60 4.20 COP (Max) 4.84 4.60 4.20
SCOP 4.70 4.80 5.00 SCOP 4.70 4.80 5.00
Color Warm Gray Warm Gray Warm Gray Color Warm Gray Warm Gray Warm Gray
Exterior Exterior
RAL Code RAL 7044 RAL 7044 RAL 7044 RAL Code RAL 7044 RAL 7044 RAL 7044
Heat Exchanger Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Heat Exchanger Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Type LG Inverter Scroll (R1) LG Inverter Scroll (R1) LG Inverter Scroll (R1) Type LG Inverter Scroll (R1) LG Inverter Scroll (R1) LG Inverter Scroll (R1)
Combination x No. (Inverter) x 1 (Inverter) x 1 (Inverter) x 1 Combination x No. (Inverter) x 1 (Inverter) x 1 (Inverter) x 1
Compressor Motor Output x Number W x No. 3,198 x 1 3,198 x 1 3,198 x 1 Compressor Motor Output x Number W x No. 3,198 x 1 3,198 x 1 3,198 x 1
Oil Type FW68D FW68D FW68D Oil Type FW68D FW68D FW68D
Oil Charge cc 1,100 1,100 1,100 Oil Charge cc 1,100 1,100 1,100
Type Axial Flow Fan Axial Flow Fan Axial Flow Fan Type Axial Flow Fan Axial Flow Fan Axial Flow Fan
Motor Output x Number W x No. 124 x 1 200 x 1 200 x 1 Motor Output x Number W x No. 124 x 1 200 x 1 200 x 1
Fan Air Flow Rate (High) m3/min x No. 60 x 1 80 x 1 80 x 1 Fan Air Flow Rate (High) m3/min x No. 60 x 1 80 x 1 80 x 1
Drive DC INVERTER DC INVERTER DC INVERTER Drive DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top Side Side Side Discharge Side / Top Side Side Side
Pipe Liquid Pipe mm (inch) Ø 9.52(3/8) Ø 9.52(3/8) Ø 9.52(3/8) Pipe Liquid Pipe mm (inch) Ø 9.52(3/8) Ø 9.52(3/8) Ø 9.52(3/8)
Connctions Gas Pipe mm (inch) Ø 15.88(5/8) Ø 15.88(5/8) Ø 19.05(3/4) Connctions Gas Pipe mm (inch) Ø 15.88(5/8) Ø 15.88(5/8) Ø 19.05(3/4)
Dimensions (W x H x D) mm x No. (950 × 834 × 330) x 1 (950 × 834 × 330) x 1 (950 × 834 × 330) x 1 Dimensions (W x H x D) mm x No. (950 × 834 × 330) x 1 (950 × 834 × 330) x 1 (950 × 834 × 330) x 1
Dimensions (W x H x D) - Shipping mm x No. (1,147 x 919 x 461) x 1 (1,147 x 919 x 461) x 1 (1,147 x 919 x 461) x 1 Dimensions (W x H x D) - Shipping mm x No. (1,147 x 919 x 461) x 1 (1,147 x 919 x 461) x 1 (1,147 x 919 x 461) x 1
Net Weight kg x No. 64.7 x 1 71.6 x 1 71.6 x 1 Net Weight kg x No. 64.7 x 1 71.6 x 1 71.6 x 1
Shipping Weight kg x No. 73.7 x 1 79.6 x 1 79.6 x 1 Shipping Weight kg x No. 73.7 x 1 79.6 x 1 79.6 x 1
Sound Pressure Cooling dB(A) 50 51 52 Sound Pressure Cooling dB(A) 50 51 52
Level Heating dB(A) 52 53 54 Level Heating dB(A) 52 53 54
Sound Power Cooling dB(A) 67 70 71 Sound Power Cooling dB(A) 67 70 71
Level Heating dB(A) 71 74 75 Level Heating dB(A) 71 74 75
mm2 x No. mm2 x No.
Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Communication Cable 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
(VCTF-SB) (VCTF-SB)
Refigerant name R32 R32 R32 Refigerant name R32 R32 R32
Precharged Amount kg 1.5 2.0 2.0 Precharged Amount kg 1.5 2.0 2.0
Refigerant Refigerant
t-CO2 eq 1.01 1.35 1.35 t-CO2 eq 1.01 1.35 1.35
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of maxmum connectable indoor units 8 10 13 Number of maxmum connectable indoor units 8 10 13

Note 4. Performances are based on the following conditions : Note 4. Performances are based on the following conditions :
1. Due to our policy of innovation some specifications may be changed without notification. • *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB 1. D
 ue to our policy of innovation some specifications may be changed without notification. • *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
2. W
 iring cable size must comply with the applicable local and national codes. And “Electric • *Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB 2. W
 iring cable size must comply with the applicable local and national codes. And “Electric • *Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
characteristics” chapter should be considered for electrical work and design. Especially the power • Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m. characteristics” chapter should be considered for electrical work and design. Especially the power • Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
cable and circuit breaker should be selected in accordance with that. 5. EUROVENT Test Condition : cable and circuit breaker should be selected in accordance with that. 5. EUROVENT Test Condition :
3. S
 ound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 • Performance values on the this PDB are based on Ceiling mounted cassette combination. 3. S
 ound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 • Performance values on the this PDB are based on Ceiling mounted cassette combination.
standard. Sound power level is measured on the rated condition in the reverberation rooms by • Refer to EUROVENT web site(www.eurovent-certification.com) for other indoor unit combination standard. Sound power level is measured on the rated condition in the reverberation rooms by • Refer to EUROVENT web site(www.eurovent-certification.com) for other indoor unit combination
ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during and more detail test conditions. ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during and more detail test conditions.
operation. 6. The maximum combination ratio is 160%. operation. 6. The maximum combination ratio is 160%.
7. This product contains Fluorinated greenhouse gases. 7. This product contains Fluorinated greenhouse gases."

068 / 069
OUTDOOR
UNITS
- Air Cooled VRF Heat Pump

MULTI V M
- 14kW (Cooling capacity based) 70m 140m
Longest piping length from Compressor
- 3Φ, 380 ~ 415V, 50Hz (Compressor Module) Module to Indoor unit
TOTAL PIPING LENGTH
- 1Φ, 220 ~ 240V, 50Hz (Heat Exchanger Module)
- Outdoor unit is installed inside building

140M
TOTAL PIPING LENGTH

30m
Longest piping
length from Heat
Exchanger Module to
Compressor Module

How does it work?

Direct Inlet / Outlet Case


Flexible design
Indoor unit

Duct
Heat
exchanger

Cost savings Compressor

Concealed VRF
technology
for enhanced Duct Connected Case

flexibility and Indoor


unit
Compressor
Space savings
aesthetic building
requirements Duct
Heat
exchanger

Easy maintenance

070 / 071
OUTDOOR UNIT _ MULTI V M _ KEY FEATURES

HIGH CLASS EFFICIENCY FLEXIBLE DESIGN & INSTALLATION

OUTDOOR
UNITS
Best-in-class inverter compressor with smart load control
and Wide Louver Plus fin technology

Energy Efficiency Wide Louver Plus Fin Module Type Heat exchanger module can be installed in false ceiling spaces

+ Corrosion Resistance Increased design freedom

MULTI V M
Cooling Efficiency (EER) Heating Efficiency (COP)
- Additional structre installation and ceiling construction
Wide Louver Plus fin technology increases efficiency and heating
not required
2.6% performance compared to conventional fin.
6.2% - Ease of service - compressor replacement
3.40 3.80 3.90 - Low noise with module
3.20

+
Ease of service (Replacement of the comp)
Low noise by module (vs Integrated Type)
A Company MULTI V M A Company MULTI V M
Module type (Eurovent) Module type (Eurovent)

R1 Compressor Conventional 100%


Heat Exchanger
Module
MULTI V M ensures world-class efficiency with innovative
technology including R1 Compressor. Wide Louver Max.
Plus Fin 128% 28% Compressor module can be installed anywhere indoors
10 indoor units
(Cooling) Max.70m
Wide Louver Max.30m
Motor Plus Fin 123% 23% Compressor
(Heating) Module
Heat exchange rate (%)

Quiet Operation
Bottom
Low sound level of both compressor module and heat exchanger
compression
section module allows outdoor units to be installed and operated inside.

Oil
New type of Flexible Piping Location
compression section
Tidy & simple installation with flexibile piping location
Smart Load Control
Top side piping
To save operation energy consumption, automatically controls the
refrigerant temperature according to outdoor temperature.
SPACE SAVING &
CONVENIENT INSTALLATION
35°C 20°C Rear side piping

Volume
Compressor Module Heat Exchanger Module
0.233 m3 0.826 m3

3°C 10°C
REGULATORY COMPLIANCE A Company
Building permit could be simplified 0.603 m3
Increased design freedom A Company 0.203 m3 B Company
0.494 m3
Additional structure installation nor ceiling construction not required, LG LG

Regulation in Spain making compressor replacement and general maintenance easier. Split
Indoor Discharge
Air Temperature

During Start up Weather Dependent module provides low noise operation compared to integrated type.

Changed by
Indoor Temperature
E.S.P. (External Static Pressure) Control
Exposure regulation of
Heat exchanger up to 30 Pa up to 157 Pa
outdoor unit on wall (max)
installation
Power Input

Compressor

Time
• Can only be installed inside the building
Up to 30% Energy Saving • Discharge air volume less than 60CMM Conventional Outdoor Unit Normal Mode High Static Pressure Mode
Smooth (Level1) SLC Contol
• Securing more than 5m distance between outdoor discharge grilles
SLC Start up
Quick (Level 2) Basic Operation (Default Setting)
• Securing at least 2.5m from the floor
Operation
Power (Level 3)
• Securing more than 2.5m from surrounding windows

072 / 073
OUTDOOR UNIT _ MULTI V M _ TECHNICAL DATA

11.1 Sound Pressure Level


Nomenclature Compressor Module 11.1 Sound Pressure
Position of Sound Level
Pressure Level Measuring

OUTDOOR
UNITS
[Compressor Module] [Heat Exchanger Module]
[Unit : mm] C
ARU N 050 L M S 0
Compressor Module Heat Exchanger Module
Serial number 36 110 [Compressor Module] [Heat Exchanger Module]
Model Type
DISCHARE SUCTION

101
S : Set Microphone
C : Compressor Module
E : Heat Exchanger Module DUCT DUCT

500
A
Outdoor unit Type

MULTI V M
1.5 m

216
M : Modular Type
Electrical Ratings 1.5 m
L : 3Ø, 380-415V, 50Hz 580
G : 1Ø, 220-240V, 50Hz 2m 2m
Total Cooling Capacity in Horse Power(HP) unit B
EX) 5HP → '050', 8HP → '080'
Combination of Inverter Type and Cooling Only 1.0 m
or Heat Pump
N: Inverter and H/P, V: Inverter and C/O * Measuring place : Anechoic chamber * Measuring place : Anechoic chamber
MULTI V System Outdoor Unit using R410A
Installation Space for Compressor Module

700
Outdoor Unit Function

512

512
352
Category Functions Modular
Installation Space for Compressor Module
Variable Path of Outdoor Unit HEX -
HiPORTM (High Pressure Oil Return) -
Key Refrigerant
Humidity Sensor -
249 327 249 Installation Space for Compressor Module
Installation Space for Compressor Module
Components
Corrosion Resistance Black Fin ○ Left Front Right

Oil Sensor - Top View b a Front View


Dual Sensing - D
c

19
Low Noise Operation ○
15
Hgih Static Mode of Outdoor Unit Fan ○
22.5
Ø15

7.5
Partial Defrosting - e

462
Auto Dust Cleaning of Outdoor Unit
-
Useful Function (Fan reverse rotation)
Installation Space for Compressor Module
Detail D
Indoor Cooling Comfort Mode Based

Outdoor Temperature

19
Smart Load Control (SLC) 25 530 25
(Changing indoor discharge air ○
temperature according to load) Front Side

Outdoor Unit Control Refer to Humidity -


Defrost / Deicing ○
High Pressure Switch ○ Service Space
(Front Side)
Phase Protection ○ d
Reliability Restart Delay (3-minutes) ○
Self Diagnosis ○ Top View Front View
Soft Start ○
Test Run Function - Installation Space
Category Mark
Description

122
AC Ez (Simple Controller) PQCSZ250S0 Top View Front View [ mm ]
AC Ez Touch PACEZA000 150 30 a Right 10 or more
AC Smart IV PACS4B000 3D View b Left Installation Space 10 or more
Category Top
Category View
Mark Compressor
Mark Front
Description View
Description Installation Space (mm)
Central Controller AC Smart 5 PACS5A000 c Rear [ mm ] 10 or more
Module
ACP (Advanced Control Platform) IV PACP4B000 a a d Right Right Front 10 or more 10 or More500 or more
ACP (Advanced Control Platform) 5 PACP5A000 Category Mark b b
Description e Left Left Installation TopSpace 10 or more 10 or More200 or more
AC Manager 5 PACM5A000 Heat Exchanger Module Compressor
Compressor
c R e a r [ mm ] 1 0 or more 10 or More
Module
a d Right Space for FHeat 10 or more
c Rear
BNU (Building ACP Lonworks PLNWKB000 [Unit : mm] Module
Installation ront Exchanger Module 500 or more
Network Unit) ACP BACnet PQNFB17C0 1681 b d e L e f t Top Front 1 0 o r m o r e 200 or more500 or More
1622
Compressor c Rear 10 or more
Installation
Refrigerant Charging Kit -
1397 Module e Top View Top 200 or More
Variable Water Flow Valve Control Kit - d Front 500 or more
Installation Space for Heat Exchanger Module
19

PDI (Power Standard - Top View e Top


Front View 200 or more
Distribution Indicator) Premium - Top View
560

Cool / Heat Selector PRDSBM Installation Space for Heat Exchanger Module
Installation Space
Category Mark Description
300

Low Ambient Kit - [ mm ]


RTop
ight View
IO Module
a 10 or more
19

PVDSMN000
(ODU Dry Contact) 850
LGMV PRCTIL0 b Left 10 or more
Cycle Monitoring Compressor c Rear 10 or more
Device Mobile LGMV PLGMVW100 Module
d Front 500 or more
※ ○ : Applied, - : Not Applied Installation
e Space for
TopCompressor Module 200 or more
292

29 28 69 335 314 335

[Unit: mm]
294

Installation Space for


Top Heat
View Exchanger Module
462
393

Heat Pump Front View


352

352

357

352

352
222

[Unit : mm] [Unit : mm]


Cooling Heating 221 1122 219 551
555 Top View [Unit: mm]
1562 Air Suction 600 x 600
Front View
113
22
95

45°C 20°C 625 (Service Inspection Hole)


111
43°C 18°C
40°C
[Unit: mm]

10 or More
15°C
242 170
Outdoor Temperature (°C WB)

Range for warming up operation


Outdoor Temperature (°C DB)

Range for continuous operation


Range for continuous operation

35°C
Front View
Range for pull down operation

10°C
30°C
5°C
25°C
Front View H = 100 or More
20°C 0°C
[Unit: mm]
15°C -5°C
Air Discharge
10°C
-10°C
5°C
1389
[Unit: mm] [Unit: mm]
-15°C 70 or More 600 or More
0°C
388

-5°C
-20°C [Unit: mm]
-25°C
-10°C
Indoor Temperature (°C WB) Front View
10°C 14°C 15°C 20°C 25°C 27°C 30°C 10°C 15°C 20°C 25°C 27°C 30°C
Indoor Temperature (°C DB)

074 / 075

[Unit: mm]
OUTDOOR UNIT _ MULTI V M _ SPECIFICATION

MULTI V M MULTI V M

OUTDOOR
UNITS
MULTI V M
LG participates in the ECP programme for EUROVENT LG participates in the ECP programme for EUROVENT
VRF program. Check ongoing validity of certification VRF program. Check ongoing validity of certification
: www.eurovent-certification.com : www.eurovent-certification.com

System Module
HP 5 HP 5
Set ARUN050LMS0 Compressor Module Heat Exchanger Module
Model Names
Model Name Compressor Module ARUN050LMC0 ARUN050LMC0 ARUN050GME0

Heat Exchanger Module ARUN050GME0 Color Morning Gray -


Exterior
RAL Code (Classic) RAL 7030 -
Cooling* (Rated) kW 14.0
Dimensions Net mm x No. 580 x 700 x 500 1,562 x 460 x 688
Capacity Heating* (Rated) kW 14.0
(W x H x D) Shipping mm x No. 618 x 833 x 564 1,806 x 537 x 825
Heating* (Max.) kW 16.0
Net kg x No. 69 x 1 84 x 1
Cooling* (Rated) kW 4.12 Weight
Shipping kg x No. 76 x 1 95 x 1
Input Heating* (Rated) kW 3.59 Type Hermetic Motor Compressor -
Heating* (Max.) kW 4.32 Combination x No. (Inverter) x 1 -
EER Based on Rated Capacity 3.40 Compressor Motor Output W x No. 3,200 -
SEER 7.03 Oil Type FVC68D (PVE) -

Based on Rated Capacity 3.90 Oil Charge cc 1,300


COP Heat Exchanger Type - Wide Louver Plus / Black Fin
Based on Max. Capacity 3.70
Type - Sirocco Fan
SCOP 4.12
Fan Motor Output x Number W x No. - 400 x 2
Number of Maximum Connectable Indoor Units 10
Air Flow Rate (Rated) m3/min x No. - 60
External Static Nominal (Rated, Factory Set) mmAq (Pa) - 3 (29)
Pressure Max. mmAq (Pa) - 16 (157)
Liquid mm (inch) Ø 9.52 (3/8) to IDU Ø 12.7 (1/2) to Comp. Module
Pipe Connctions Gas mm (inch) Ø 15.88 (5/8) to IDU Ø 19.05 (3/4) to Comp. Module
Drain mm (inch) - Ø 25 (1)
Sound Pressure Cooling (Rated) dB(A) 45.0 45.0
Level Heating (Rated) dB(A) 45.0 45.0
Sound Power Level dB(A) 59.0 72.0
mm2 x No.
Communication Cable 1.0 ~ 1.5 x 2C to IDU 1.0 ~ 1.5 x 2C to Comp. Module
(VCTF-SB)
Refigerant Name R410A R410A
Precharged Amount kg 2.0 -
Refrigerant
t-CO2 eq. 4.175 -
Control - Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 1, 220 ~ 240, 50

※ ○ : Applied, - : Not Applied ※ ○ : Applied, - : Not Applied


Note Note
1. Due to our policy of innovation some specifications may be changed without notification. 1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design. Especially the 2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design. Especially the
power cable and circuit breaker should be selected in accordance with that. power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions. 3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms 4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation. by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions : 5. Performances are based on the following conditions :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB • *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• *Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB • *Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length and Difference of Elevation : – Heat Exchanger Module ~ Compressor Module = 5m • Interconnected Pipe Length and Difference of Elevation : – Heat Exchanger Module ~ Compressor Module = 5m
– Compressor Module ~ Indoor Unit = 7.5m – Compressor Module ~ Indoor Unit = 7.5m
– Difference of Elevation (Heat Exchanger Module~ Compressor Moduler ~ Indoor Unit) is Zero – Difference of Elevation (Heat Exchanger Module~ Compressor Moduler ~ Indoor Unit) is Zero
6. The maximum combination ratio is 130%. 6. The maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2,087.5) 7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2,087.5)

076 / 077
OUTDOOR
UNITS
MULTI V WATER IV
- Water Cooled VRF Heat Pump & Heat Recovery
- 22.4 ~ 201.6kw (Cooling capacity based)

300M
- 3Φ, 380 ~ 415V, 50Hz Longest piping length after 1st branch
40m (Conditional application)
- Outdoor unit installed indoor

40m
Height between
IDU ~ IDU

TOTAL PIPING LENGTH


50m
Height between
ODU ~ IDU

Longest piping length from


150m ODU ~ IDU (Equivalent)

How does it work?


Operation independent of weather conditions

Energy savings
Outdoor Wind
Temp.

Available in Heat Pump & Heat Recovery Configuration


Energy saving by heat
recovery unit

Heating based
Space savings Simultaneous operation
External energy saving by between
heat recovery system

Economical,
Cooling based
Simultaneous operation

efficient system Geothermal Application


37℃
Convenient Cooling
32℃
Tower
installation
Water
Pump
Control
Room 1 Room 2 Room 3 Panel

Under Ground MULTI V


HEX WATER IV

078 / 079
OUTDOOR UNIT _ MULTI V WATER IV _ KEY FEATURES

INNOVATIVE ENERGY SAVING WATER SAVINGS FLEXIBLE DESIGN &

OUTDOOR
TECHNOLOGIES SPACE SAVINGS

UNITS
Economical, Highly Efficient System Variable Water Flow Control (Option)
LG’s key technologies are integrated to inverter compressor In support of green building initiatives
High Efficiency System Regardless of With 4th generation inverter compressor, the Multi V Water IV The world’s first variable water flow control system for water cooled
Largest Capacity
External Conditions boasts top-class energy efficiency. VRF system. LG applied Variable Water Flow Control to optimize
Sufficient pipe length limitation provides flexible design

MULTI V WATER IV
water flow control regarding partial cooling or heating load conditions. and installation
Regardless of outdoor temperature and other environmental conditions,
Extended Compressor Speed 20Hz ~ 140Hz Because of this it’s also possible to reduce circulation pump energy
MULTI V WATER IV is the optimal solution. Providing 8 ~ 20HP (22.4 ~ 56kW) with single unit, and up to the
- Rapid operation response consumption.
- Capable of reaching required temperature quickly
world’s largest capacity 80HP (224kW) by combination.
- Increase part load efficiency
HP 8 10 14 20 22 24 28 30 34 40 42 ~ 60 62 ~ 80
kW 22.4 28 39.2 56 61.6 67.2 78.4 84 95.2 112 117.6 ~ 168 173.6 ~ 224
HiPORTM (High Pressure Oil Return) Variable Water
-E liminating loss in suction gas by returning oil directly Flow Control Valve
to compressor LG
CoolingTower DC 0 ~ 10V
- Resolve compressor efficiency loss caused by oil return
1 Unit 2 Units 3 Units 4 Units
Active oil control (Oil level sensor)
- Oil recovery operation occurs only when required
Outdoor Temp. Wind - Enhanced compressor reliability & continuous heating Inverter
Pump
Longest Piping Length
Geothermal
- Oil distribution between compressors Sufficient pipes length limitation in design and Installation
PWFCKN00 of immense variety of building
Maximum COP River / Sea
Provide flexible installation up to 300m of total piping length.
COP

Maximum COP 8.5 As water pipes are not connected to indoor units, users are free
7
MULTI V WATER IV System for from water leakage problems.

Total Water Flow (m3)


6
Geothermal Applications 15,456 Longest piping length Height
5
Uses underground heat sources like soil, ground water, lakes, rivers and after 1st branch difference 50m
Cooling based Heating based 71%
4
more as renewable energy for cooling and heating. Water or antifreeze operation operation
Height
solution is circulated through the closed loop HDPE (High Density Poly- 0 between IDU
Ethylene) pipes buried beneath the earth’s surface. 20 40 60 80 100 Operation Ratio (%)
* Outdoor unit water inlet temperature : 7°C
* Indoor temperature : 20°C DB / 15°C WB 4,439
- The Circulating water temperature range is between -5°C ~ 45°C * Maximum COP Condition : Cooling 40% + Heating 60% operation
Total Piping Length 300m
- Antifreeze should be applied depending on the application.
Constant Water Flow Variable Water Flow Actual longest piping length (Equivalent) 150m (175m)
Economical, Highly Efficient System
2,000 Note Longest piping length after 1st branch (Conditional application) 40m (90m)
Power Input (kWh)

1. Location : Paris, France


1,800 Height difference between ODU ~ IDU 50m
Average 2. Office, 68,000m2
1,600 3. Operation time : 1,344 hours (cooling period)
energy saving Height difference between IDU ~ IDU 40m
1,400
1,200 12%
1,000
800
600
Compact Size
400 Project Example : 63F (Pump : 20,064 LPM, 42.4mAq * 4ea) Thanks to compact size of product, it provides more space
200
Previous Model MULTI V WATER IV
1) Inverter pump with MULTI V WATER and variable water flow control kit for commercial or public use as much as possible.
2) Constant pump (Step control) with Water cooled VRF
Pump
The optimal design of the compact, lightweight outdoor unit enables
Machine Room
MULTI V WATER IV
LG’s 4th Generation Inverter Compressor double stacking, which results in 50% savings in installation space.
10 years energy cost ($)
Efficiency (EER)

5.5 5% HEX Optimization

Total Water Flow (m3)


10%
Under ground 2% Cycle Composition Conventional MULTI V WATER IV
HEX Improvement
5.0 2,600,518 36%
1% Inverter Control [100%] 61%
1% Active Oil Control Reduced

1% HiPOR™
Chiller - FCU MULTI V WATER IV 1,653,093 28kW x 4EA 56kW x 2EA
Cooling Tower Per each Per each
Cooling Tower (Open type cooling towers can be used.) Previous Model MULTI V WATER IV 880 x 550 mm 755 x 500 mm
Ref. * Comparison between 10HP (28kW) in cooling mode
pipe. * 112kw, Floor area based
(Independent
control)
Integrated Part Load Efficiency Constant Pump Inverter Pump
Lightweight
Efficiency (EER)

FCU 6% HEX Optimization


13% 6.7
4% Cycle Composition
5 years 10 years
Nothing or Decrease additional load reinforcement work at building
Improvement
5.8 Unit
1% Inverter Control Energy Use Pump Running Energy Use Pump Running Easier to transport and install thanks to 18% reduction in overall weight.
1% Active Oil Control (kWh) Cost ($) (kWh) Cost ($)
AHU
1% HiPOR™
MULTI V Constant pump 7,952,040 1,142,441 15,904,080 2,600,518 18% 127kg
WATER IV Reduced
MULTI V WATER IV
Water piping
Inverter pump 5,054,940 726,225 10,109,880 1,653,093 154kg
Water
Cooled Chiller Pump Pump Boiler Boiler MULTI V WATER II MULTI V WATER IV Previous Model
(Space Saving) • Power consumption rate : 0.13$/kWh
Water piping Pump • Annual power consumption rate expected to increase by 5% * Based on 28kW
Central control Independent control

080 / 081
OUTDOOR UNIT _ MULTI V WATER IV _ TECHNICAL DATA

Nomenclature Operation Limits MULTI V WATER IV Heating Dissipation Value by Model Precaution of Installation

OUTDOOR
UNITS
ARW N 100 L A S 4 Model HP Heating Dissipation Value 1. Do not install the unit at the outdoors. (Installation of the unit
Cooling Heating
ARWN080LAS4 8 600 W 515.9 kcal/h 0.143 kcal/s outdoors could result in fire or electric shock.) Recommended
Serial number ambient temperature of outdoor unit is between 0 ~ 40°C
45 45 ARWN100LAS4 10 630 W 541.7 kcal/h 0.150 kcal/s

Range for continuous operation


S : Standard 40 40 ARWN120LAS4 12 660 W 567.5 kcal/h 0.158 kcal/s 2. Keep the water temperature between 10 ~ 45°C. Standard water

Inlet water Temperature (°C)

Inlet water Temperature (°C)

Range for warming up operation

Range for continuous


Range for pull down operation
35 35
A : Basic Function ARWN140LAS4 14 690 W 593.3 kcal/h 0.165 kcal/s supply temperature is 30°C for cooling and 20°C for heating.

operation

MULTI V WATER IV
30
30 ARWN160LAS4 16 700 W 601.9 kcal/h 0.167 kcal/s
Electrical Ratings 3. Establish an anti-freeze plan for the water supply when the
25
L : 3Ø, 380 ~ 415 V, 50Hz ARWN180LAS4 18 720 W 619.1 kcal/h 0.172 kcal/s product is stopped during the winter.
25
20 ARWN200LAS4 20 750 W 644.9 kcal/h 0.179 kcal/s
Total Cooling Capacity in Horse
Power(HP) unit
20 4. Be careful of the water purity control. Ensure water purity
15 Test condition : 1) Indoor air temperature : DB 40℃, WB : 32℃
EX) 10HP → '100' ※ A design stage should be considered to ventilation system in mechanical room. control to avoid breakdown due to water pipe corrosion. Refer to
15 Range for
Range for
10 operation ‘Standard Table for Water Purity Control’ in PDB (Product Data
Combination of Inverter Type and Cooling Only operation
or Heat Pump 10 -5 Book)
10 15 20 25 30 10 15 20 25 30
N: Inverter and H/P
ARWN080LAS4 / ARWN100LAS4 / ARWN140LAS4 5. The water pressure resistance of the water pipe system of this
Indoor Temperature (°CWB) Indoor Temperature (°CDB)
MULTI V Water System with Outdoor unit / ARWN200LAS4 product is 1.98MPa
using R410A [Unit : mm]
Note
1. These figures assume the following operating conditions: 755 6. Always install a trap so that the drained water does not back flush
2. Equivalent piping length :7.5m
3. Level difference : 0m
7. Install a pressure gauge and temperature gauge at the inlet and
Outdoor Unit Function outlet of the water pipe.

500
Category Functions MULTI V WATER IV
Variable Path of Outdoor unit HEX -
8. Flexible joints must be installed not to cause any leakage from
the vibration of pipes.
HiPOR TM
(High Pressure Oil Return) ○ Position of Sound Pressure Level Measuring
Key Refrigerant
Humidity Sensor -
Components 9. Install a service port to clean the heat exchanger at the each end
Corrosion Resistance Black Fin -
of the water inlet and outlet.
Oil Sensor ○ Liquid pipe 79
Gas pipe 79
Dual Sensing - High/Low pressure 10. It is recommended to install the flow switch to the water
Common 79
Low Noise Operation -
Water pipe outlet
collection pipe system connecting to the outdoor unit. (Flow switch
Hgih Static Mode of Outdoor Unit Fan - 58 acts as the 1st protection device when the heat water is not

997
Partial Defrosting - supplied.)

913
828
742
Auto Dust Cleaning of Outdoor Unit

635
-
Useful Function (Fan reverse rotation) 58 11. When setting the flow switch, it is recommended to use the

420
Indoor Cooling Comfort Mode Based
-
Water
pipe inlet product with default set value to satisfy the minimum flow rate of
Outdoor Temperature

169
this product. (The minimum flow rate range of this product is 50%.)

95
Smart Load Control (SLC)
(Changing indoor discharge air - 345 250
temperature according to load) 378
500
12. To protect the water cooling type product, you must install a
Note 755
Outdoor Unit Control Refer to Humidity - 1. Data is valid at free field condition strainer with 50 mesh or more on the heat water supply pipe.
2. Data is valid at nominal operating condition If not installed, it can result in damage of heat exchanger by the
Defrost / Deicing - 3. Sound level will vary depending on a range of factors such as the construction
High Pressure Switch ○ (acoustic absorption coefficient) of particular room in which the equipment is installed following situation.
4. Sound level can be increased in static pressure mode or air guide application. Individual Installation
Phase Protection ○ 1) Heat water supply within the plate type heat exchanger is
Reliability Restart Delay (3-minutes) ○ composed of multiple small paths.
Self Diagnosis ○ 2) If you do not use a strainer with 50 mesh or more, alien
Soft Start ○ particles can partially block the water paths.
Optional Accessories 3) When running the heater, the plate type heat exchanger plays
Test Run Function ○
AC Ez (Simple Controller) PQCSZ250S0 No. Name Model the role of the evaporator, and at this time, the temperature
AC Ez Touch PACEZA000 ARBLN01621 of the refrigerant side drops to drop the temperature of the
AC Smart IV PACS4B000 ARBLN03321 heat water supply, which can result in icing point in the water
Central Controller AC Smart 5 PACS5A000 1 Y branch pipe ARBLN07121 paths.
ACP (Advanced Control Platform) IV PQCPC22A0 4) As the heating process progresses, the water paths can
ARBLN14521
ACP (Advanced Control Platform) 5 PACP5A000 be partially frozen to lead to damage in plate type heat
ARBLN23220
AC Manager 5 PACM5A000 exchanger.
ACP Lonworks PLNWKB000 ARBL054 5) As a result of the damage of the heat exchanger from the
BNU (Building
Network Unit) ACP BACnet PQNFB17C0 ARBL057 freezing, the refrigerant side and the heat water source side
Refrigerant Charging Kit - ARBL104 will be mixed to make the product unusable.
Installation 2 Header
Variable Water Flow Valve Control Kit PWFCKN000 ARBL107
PDI (Power Standard PPWRDB000
Water Piping Installation
Distribution ARBL1010
Indicator) Premium PQNUD1S40
ARBL2010
Cool / Heat Selector PRDSBM
ARCNN21
Low Ambient Kit -
3 Connection pipe of Outdoor Units ARCNN31
IO Module (ODU Dry Contact) PVDSMN000
LGMV PRCTIL0 ARCNN41
Cycle Monitoring
Device Mobile LGMV PLGMVW100
※ ○ : Applied, - : Not Applied

082 / 083
OUTDOOR UNIT _ MULTI V WATER IV _ REFERENCE SITE OUTDOOR UNIT _ MULTI V WATER IV _ SPECIFICATION

REFERENCE SITE MULTI V WATER IV HEAT PUMP

OUTDOOR
UNITS
Bouygues Challenger
ARWN080LAS4 / ARWN100LAS4
LG MULTI V WATER Solution with Geothermal Application
ARWN140LAS4

MULTI V WATER IV
HP 8 10 14
Combination Unit ARWN080LAS4 ARWN100LAS4 ARWN140LAS4
Model Name
Independent Unit ARWN080LAS4 ARWN100LAS4 ARWN140LAS4
Cooling (Rated) kW 22.4 28.0 39.2
Capacity
Heating (Rated) kW 25.2 31.5 44.1
Cooling (Rated) kW 3.86 5.09 7.84
Input
Heating (Rated) kW 4.2 5.34 8.17
EER 5.80 5.50 5.00
COP Rated Capacity 6.00 5.90 5.40
Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 10.7 15.8 28.6
Rated Water Flow LPM 77 96 135
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 1 (Inverter) x 1 (Inverter) x 1
Motor Output x
Compressor W x No. 4,200 x 1 4,200 x 1 4,200 x 1
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 2,800 2,800 2,800
Refrigerant Liquid Pipe mm (inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 12.7 (1/2)
Connecting Pipes Gas Pipe mm (inch) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 25.4 (1)
Inlet A (inch) 40A(PT 1-1/2) (Internal Thread) 40A(PT 1-1/2) (Internal Thread) 40A(PT 1-1/2) (Internal Thread)
Water Connecting
Outlet A (inch) 40A(PT 1-1/2) (Internal Thread) 40A(PT 1-1/2) (Internal Thread) 40A(PT 1-1/2) (Internal Thread)
Pipes
Drain Outlet A (inch) 20A(PT 3/4) (External Thread) 20A(PT 3/4) (External Thread) 20A(PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 1 (755 x 997 x 500) x 1 (755 x 997 x 500) x 1
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 1 (804 x 1,143 x 630) x 1 (804 x 1,143 x 630) x 1
Net Weight kg x No. 127 x 1 127 x 1 127 x 1
Shipping Weight kg x No. 137 x 1 137 x 1 137 x 1
Sound Pressure Cooling dB(A) 47.0 50.0 58.0
Site Information Level Heating dB(A) 51.0 53.0 57.0
Cooling dB(A) 59.0 62.0 70.0
The industrial group Bouygues was established in France in 1952. It now maintains operations in 80 countries and employs more than 131,000 people. Sound Power Level
Heating dB(A) 63.0 65.0 69.0
In 1988, after two years of construction, the new headquarters for Bouygues Construction was officially opened for business. Named Challenger, the Communication mm2 x No.
1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
Cable (VCTF-SB)
complex became a technological showcase for late 20th century architecture.
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 5.8 5.8 5.8
Refrigerant Factory
t-CO2 eq. 12.1 12.1 12.1
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
LG Solution Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Bouygues decided to convert their headquarters into an eco-friendly building by significantly reducing its energy footprint. The LG MULTI V Water system Number of Maximum Connectable Indoor Units 1) 13 (20) 16 (25) 23 (35)

was chosen as the ideal HVAC solution for this project. The system not only saves energy but also reduces water usage as it recycles water in order to
regulate the temperature of the building. With LG’s advanced technology, the building’s water consumption was reduced by more than 70 percent.

Note
1. M
 aximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination(160% ~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F)
- Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. S
 ound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)

084 / 085
OUTDOOR UNIT _ MULTI V WATER IV _ SPECIFICATION

MULTI V WATER IV HEAT PUMP MULTI V WATER IV HEAT PUMP

OUTDOOR
UNITS
ARWN200LAS4 / ARWN160LAS4 ARWN220LAS4 / ARWN240LAS4
ARWN180LAS4 ARWN280LAS4

MULTI V WATER IV
HP 20 16 18 HP 22 24 28
Combination Unit ARWN200LAS4 ARWN160LAS4 ARWN180LAS4 Combination Unit ARWN220LAS4 ARWN240LAS4 ARWN280LAS4
Model Name ARWN080LAS4 ARWN100LAS4 Model Name ARWN140LAS4 ARWN140LAS4 ARWN140LAS4
Independent Unit ARWN200LAS4 Independent Unit
ARWN080LAS4 ARWN080LAS4 ARWN080LAS4 ARWN100LAS4 ARWN140LAS4
Cooling (Rated) kW 56.0 44.8 50.4 Cooling (Rated) kW 61.6 67.2 78.4
Capacity Capacity
Heating (Rated) kW 63.0 50.4 56.7 Heating (Rated) kW 69.3 75.6 88.2
Cooling (Rated) kW 11.20 7.72 8.95 Cooling (Rated) kW 11.70 12.93 15.68
Input Input
Heating (Rated) kW 11.67 8.40 9.54 Heating (Rated) kW 12.37 13.51 16.34
EER 5.00 5.80 5.63 EER 5.26 5.20 5.00
COP Rated Capacity 5.40 6.00 5.94 COP Rated Capacity 5.60 5.60 5.40
Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray
Exterior Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure Maximum Pressure
kgf/cm2 45 45 45 kgf/cm2 45 45 45
Heat Exchanger Resistance Heat Exchanger Resistance
Head Loss kPa 30.1 10.7 + 10.7 15.8 + 10.7 Head Loss kPa 28.6 + 10.7 28.6 + 15.8 28.6 + 28.6
Rated Water Flow LPM 192 77 + 77 96 + 77 Rated Water Flow LPM 135 + 77 135 + 96 135 + 135
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 1 (Inverter) x 2 (Inverter) x 2 Combination x No. (Inverter) x 2 (Inverter) x 2 (Inverter) x 2
Motor Output x Motor Output x
Compressor W x No. 5,300 x 1 4,200 x 2 4,200 x 2 Compressor W x No. 4,200 x 2 4,200 x 2 4,200 x 2
Number Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 3,000 5,600 5,600 Oil Charge cc 5,600 5,600 5,600
Refrigerant Liquid Pipe mm (inch) Ø 12.7 (1/2) Ø 12.7 (1/2) Ø 12.7 (1/2) Refrigerant Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4)
Connecting Pipes Gas Pipe mm (inch) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8) Connecting Pipes Gas Pipe mm (inch) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8)
40A(PT 1-1/2) + 40A(PT 1-1/2) 40A(PT 1-1/2) + 40A(PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Inlet A (inch) 40A(PT 1-1/2) (Internal Thread) Inlet A (inch)
(Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread)
Water Connecting 40A(PT 1-1/2) + 40A(PT 1-1/2) 40A(PT 1-1/2) + 40A(PT 1-1/2) Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Pipes Outlet A (inch) 40A(PT 1-1/2) (Internal Thread) Pipes Outlet A (inch)
(Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread)
Drain Outlet A (inch) 20A(PT 3/4) (External Thread) 20A(PT 3/4) (External Thread) 20A(PT 3/4) (External Thread) Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 1 (755 x 997 x 500) x 2 (755 x 997 x 500) x 2 Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 2 (755 x 997 x 500) x 2 (755 x 997 x 500) x 2
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 1 (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2 Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2
Net Weight kg x No. 140 x 1 127 x 2 127 x 2 Net Weight kg x No. 127 x 2 127 x 2 127 x 2
Shipping Weight kg x No. 150 x 1 137 x 2 137 x 2 Shipping Weight kg x No. 137 x 2 137 x 2 137 x 2
Sound Pressure Cooling dB(A) 54.0 50.0 51.8 Sound Pressure Cooling dB(A) 58.3 58.6 59.0
Level Heating dB(A) 60.0 54.0 55.1 Level Heating dB(A) 58.0 58.5 58.0
Cooling dB(A) 66.0 62.0 63.8 Cooling dB(A) 70.3 70.6 72.0
Sound Power Level Sound Power Level
Heating dB(A) 72.0 66.0 67.1 Heating dB(A) 70.0 70.5 71.0
Communication mm2 x No. Communication mm2 x No.
1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
Cable (VCTF-SB) Cable (VCTF-SB)
Refrigerant Name R410A R410A R410A Refrigerant Name R410A R410A R410A
Precharged Amount in Precharged Amount in
kg 3.0 11.6 11.6 kg 11.6 11.6 11.6
Refrigerant Factory Refrigerant Factory
t-CO2 eq. 6.3 24.2 24.2 t-CO2 eq. 24.2 24.2 24.2
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 32 (50) 26 (40) 29 (45) Number of Maximum Connectable Indoor Units 1) 35 (44) 39 (48) 45 (56)

Note Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance 1. M
 aximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination(160% ~ 200%). The recommended ratio is 130%. with outdoor units combination(160% ~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification 2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions 3. Performances are based on the following conditions
- Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F) - Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F)
- Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F) - Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m. - Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms 4. S
 ound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation. by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A) 5. This product contains Fluorinated Greenhouse Gases. (R410A)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.) 6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)

086 / 087
OUTDOOR UNIT _ MULTI V WATER IV _ SPECIFICATION

MULTI V WATER IV HEAT PUMP MULTI V WATER IV HEAT PUMP

OUTDOOR
UNITS
ARWN220LAS4 / ARWN240LAS4 ARWN420LAS4 / ARWN440LAS4
ARWN280LAS4 ARWN480LAS4

MULTI V WATER IV
HP 30 34 40 HP 42 44 48
Combination Unit ARWN300LAS4 ARWN340LAS4 ARWN400LAS4 Combination Unit ARWN420LAS4 ARWN440LAS4 ARWN480LAS4
Model Name ARWN200LAS4 ARWN200LAS4 ARWN200LAS4 ARWN200LAS4 ARWN200LAS4 ARWN200LAS4
Independent Unit Model Name
ARWN100LAS4 ARWN140LAS4 ARWN200LAS4 Independent Unit ARWN140LAS4 ARWN140LAS4 ARWN140LAS4
Cooling (Rated) kW 84.0 95.2 112.0 ARWN080LAS4 ARWN100LAS4 ARWN140LAS4
Capacity Cooling (Rated) kW 117.6 123.2 134.4
Heating (Rated) kW 94.5 107.1 126.0 Capacity
Cooling (Rated) kW 16.29 19.04 22.40 Heating (Rated) kW 132.3 138.6 151.2
Input Cooling (Rated) kW 22.9 24.13 26.88
Heating (Rated) kW 17.01 19.84 23.34 Input
EER 5.16 5.00 5.00 Heating (Rated) kW 24.04 25.18 28.01

COP Rated Capacity 5.56 5.40 5.40 EER 5.14 5.11 5.00

Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray COP Rated Capacity 5.50 5.50 5.40
Exterior Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 Exterior
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Maximum Pressure Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
kgf/cm2 45 45 45
Heat Exchanger Resistance Maximum Pressure
kgf/cm2 45 45 45
Head Loss kPa 30.1 + 15.8 30.1 + 28.6 30.1 + 30.1 Heat Exchanger Resistance
Rated Water Flow LPM 192 + 96 192 + 135 192 + 192 Head Loss kPa 30.1 + 28.6 + 10.7 30.1 + 28.6 + 15.8 30.1 + 28.6 + 28.6

Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Rated Water Flow LPM 192 + 135 + 77 192 + 135 + 96 192 + 135 + 135

Combination x No. (Inverter) x 2 (Inverter) x 2 (Inverter) x 2 Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Motor Output x Combination x No. (Inverter) x 3 (Inverter) x 3 (Inverter) x 3
Compressor W x No. 5,300 x 1 + 4,200 x 1 5,300 x 1 + 4,200 x 1 5,300 x 2
Number Motor Output x
Compressor W x No. 5,300 x 1 + 4,200 x 2 5,300 x 1 + 4,200 x 2 5,300 x 1 + 4,200 x 2
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) Number
Oil Charge cc 5,800 5,800 6,000 Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)

Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) Oil Charge cc 8,600 8,600 8,600
Refrigerant
Connecting Pipes Gas Pipe mm (inch) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Ø 41.3 (1-5/8) Refrigerant Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4)
Connecting Pipes Gas Pipe mm (inch) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8)
40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Inlet A (inch)
(Internal Thread) (Internal Thread) (Internal Thread) 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) +
Water Connecting Inlet A (inch)
40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread)
Pipes Outlet A (inch) Water Connecting
(Internal Thread) (Internal Thread) (Internal Thread) 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) +
Pipes Outlet A (inch)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 2 (755 x 997 x 500) x 2 (755 x 997 x 500) x 2 Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)

Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2 Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 3 (755 x 997 x 500) x 3 (755 x 997 x 500) x 3

Net Weight kg x No. (140 x 1) + (127 x 1) (140 x 1) + (127 x 1) 140 x 2 Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3

Shipping Weight kg x No. (150 x 1) + (137 x 1) (150 x 1) + (137 x 1) 150 x 2 Net Weight kg x No. (140 x 1) + (127 X 2) (140 x 1) + (127 X 2) (140 x 1) + (127 X 2)

Cooling dB(A) 55.5 59.0 55.0 Shipping Weight kg x No. (150 x 1) + (137 X 2) (150 x 1) + (137 X 2) (150 x 1) + (137 X 2)
Sound Pressure
Level Heating dB(A) 60.8 61.0 61.0 Sound Pressure Cooling dB(A) 59.7 59.9 60.0
Level Heating dB(A) 62.1 62.3 62.0
Cooling dB(A) 67.5 72.0 68.0
Sound Power Level Cooling dB(A) 71.7 71.9 74.0
Heating dB(A) 72.8 74.0 74.0 Sound Power Level
Communication mm2 x No. Heating dB(A) 74.1 74.3 76.0
1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
Cable (VCTF-SB) Communication mm2 x No.
1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
Refrigerant Name R410A R410A R410A Cable (VCTF-SB)
Precharged Amount in Refrigerant Name R410A R410A R410A
kg 8.8 8.8 6.0
Refrigerant Factory Precharged Amount in
kg 14.6 14.6 14.6
t-CO2 eq. 18.4 18.4 12.5 Refrigerant Factory
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve t-CO2 eq. 30.5 30.5 30.5

Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve

Number of Maximum Connectable Indoor Units 1)


49 (60) 55 (64) 64 Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 64 64 64

Note Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance 1. M
 aximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination(160% ~ 200%). The recommended ratio is 130%. with outdoor units combination(160% ~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification 2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions 3. Performances are based on the following conditions
- Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F) - Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F)
- Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F) - Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m. - Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms 4. S
 ound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation. by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A) 5. This product contains Fluorinated Greenhouse Gases. (R410A)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.) 6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)

088 / 089
OUTDOOR UNIT _ MULTI V WATER IV _ SPECIFICATION

MULTI V WATER IV HEAT PUMP MULTI V WATER IV HEAT PUMP

OUTDOOR
UNITS
ARWN500LAS4 / ARWN540LAS4 ARWN620LAS4 / ARWN640LAS4
ARWN600LAS4 ARWN680LAS4

MULTI V WATER IV
HP 50 54 60 HP 62 64 68
Combination Unit ARWN500LAS4 ARWN540LAS4 ARWN600LAS4 Combination Unit ARWN620LAS4 ARWN640LAS4 ARWN680LAS4
Model Name ARWN200LAS4 ARWN200LAS4 ARWN200LAS4 ARWN200LAS4 ARWN200LAS4 ARWN200LAS4
Independent Unit ARWN200LAS4 ARWN200LAS4 ARWN200LAS4 Model Name ARWN200LAS4 ARWN200LAS4 ARWN200LAS4
Independent Unit
ARWN100LAS4 ARWN140LAS4 ARWN200LAS4 ARWN140LAS4 ARWN140LAS4 ARWN140LAS4
Cooling (Rated) kW 140.0 151.2 168.0 ARWN080LAS4 ARWN100LAS4 ARWN140LAS4
Capacity Cooling (Rated) kW 173.6 179.2 190.4
Heating (Rated) kW 157.5 170.1 189.0 Capacity
Heating (Rated) kW 195.3 201.6 214.2
Cooling (Rated) kW 27.49 30.24 33.60
Input Cooling (Rated) kW 34.10 35.33 38.08
Heating (Rated) kW 28.68 31.51 35.01 Input
Heating (Rated) kW 35.71 36.85 39.68
EER 5.09 5.00 5.00
EER 5.09 5.07 5.00
COP Rated Capacity 5.49 5.40 5.40
COP Rated Capacity 5.47 5.47 5.40
Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray
Exterior Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45 Maximum Pressure
Heat Exchanger Resistance kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 30.1 + 30.1 + 15.8 30.1 + 28.6 + 28.6 30.1 + 30.1 + 30.1
Head Loss kPa 30.1 + 30.1 + 28.6 + 10.7 30.1 + 30.1 + 28.6 + 15.8 30.1 + 30.1 + 28.6 + 28.6
Rated Water Flow LPM 192 + 192 + 96 192 + 192 + 135 192 + 192+ 192
Rated Water Flow LPM 192 + 192 + 135 + 77 192 + 192 + 135 + 96 192 + 192 + 135 + 135
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 3 (Inverter) x 3 (Inverter) x 3 Combination x No. (Inverter) x 4 (Inverter) x 4 (Inverter) x 4
Motor Output x Motor Output x
Compressor W x No. 5,300 x 2 + 4,200 x 1 5,300 x 2 + 4,200 x 1 5,300 x 3 Compressor W x No. 5,300 x 2 + 4,200 x 2 5,300 x 2 + 4,200 x 2 5,300 x 2 + 4,200 x 2
Number Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 8,800 8,800 9,000 Oil Charge cc 11,600 11,600 11,600
Refrigerant Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) Liquid Pipe mm (inch) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8)
Refrigerant
Connecting Pipes Gas Pipe mm (inch) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Connecting Pipes Gas Pipe mm (inch) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) Ø 53.98 (2-1/8)
40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Inlet A (inch)
40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) Inlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40
Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) +
Outlet A (inch) (Internal Thread) (Internal Thread) (Internal Thread)
Pipes 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) Pipes Outlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40
(Internal Thread) (Internal Thread) (Internal Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 3 (755 x 997 x 500) x 3 (755 x 997 x 500) x 3
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 4 (755 x 997 x 500) x 4 (755 x 997 x 500) x 4
Net Weight kg x No. (140 x 2) + (127 x 1) (140 x 2) + (127 x 1) 140 x 3
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4
Shipping Weight kg x No. (150 x 2) + (137 x 1) (150 x 2) + (137 x 1) 150 x 3
Net Weight kg x No. (140 x 2) + (127 x 2) (140 x 2) + (127 x 2) (140 x 2) + (127 x 2)
Sound Pressure Cooling dB(A) 57.8 60.0 56.0
Shipping Weight kg x No. (150 x 2) + (137 x 2) (150 x 2) + (137 x 2) (150 x 2) + (137 x 2)
Level Heating dB(A) 63.4 62.0 62.0
Sound Pressure Cooling dB(A) 60.7 60.9 61.0
Cooling dB(A) 69.8 74.0 70.0 Level
Sound Power Level Heating dB(A) 64.2 64.3 63.0
Heating dB(A) 75.4 76.0 76.0
Cooling dB(A) 72.7 72.9 75.0
Communication mm2 x No. Sound Power Level
1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Heating dB(A) 76.2 76.3 77.0
Cable (VCTF-SB)
Refrigerant Name R410A R410A R410A Communication mm2 x No.
1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
Cable (VCTF-SB)
Precharged Amount in
kg 11.8 11.8 9.0 Refrigerant Name R410A R410A R410A
Refrigerant Factory
t-CO2 eq. 24.6 24.6 18.8 Precharged Amount in
kg 17.6 17.6 17.6
Refrigerant Factory
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve t-CO2 eq. 36.7 36.7 36.7
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Number of Maximum Connectable Indoor Units 1) 64 64 64 Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 64 64 64

Note Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance 1. M
 aximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination(160% ~ 200%). The recommended ratio is 130%. with outdoor units combination(160% ~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification 2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions 3. Performances are based on the following conditions
- Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F) - Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F)
- Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F) - Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m. - Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms 4. S
 ound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation. by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A) 5. This product contains Fluorinated Greenhouse Gases. (R410A)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.) 6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)

090 / 091
OUTDOOR UNIT _ MULTI V WATER IV _ SPECIFICATION

MULTI V WATER IV HEAT PUMP MULTI V WATER IV HEAT RECOVERY

OUTDOOR
UNITS
ARWN700LAS4 / ARWN740LAS4 ARWB080LAS4 / ARWB100LAS4
ARWN800LAS4 ARWB140LAS4

MULTI V WATER IV
HP 70 74 80 HP 8 10 14
Combination Unit ARWN700LAS4 ARWN740LAS4 ARWN800LAS4 Combination Unit ARWB080LAS4 ARWB100LAS4 ARWB140LAS4
Model Name
ARWN200LAS4 ARWN200LAS4 ARWN200LAS4 Independent Unit ARWB080LAS4 ARWB100LAS4 ARWB140LAS4
Model Name ARWN200LAS4 ARWN200LAS4 ARWN200LAS4
Independent Unit Cooling (Rated) kW 22.4 28.0 39.2
ARWN200LAS4 ARWN200LAS4 ARWN200LAS4 Capacity
ARWN100LAS4 ARWN140LAS4 ARWN200LAS4 Heating (Rated) kW 25.2 31.5 44.1
Cooling (Rated) kW 196.0 207.2 224.0 Cooling (Rated) kW 3.86 5.09 7.84
Capacity Input
Heating (Rated) kW 220.5 233.1 252.0 Heating (Rated) kW 4.20 5.34 8.17
Cooling (Rated) kW 38.69 41.44 44.80 EER 5.80 5.50 5.00
Input
Heating (Rated) kW 40.35 43.18 46.68 COP Rated Capacity 6.00 5.90 5.40
EER 5.07 5.00 5.00 Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray
Exterior
COP Rated Capacity 5.46 5.40 5.40 RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 Maximum Pressure
kgf/cm2 45 45 45
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate Heat Exchanger Resistance
Maximum Pressure Head Loss kPa 10.7 15.8 28.6
kgf/cm2 45 45 45
Heat Exchanger Resistance Rated Water Flow LPM 77 96 135
Head Loss kPa 30.1 + 30.1 + 30.1 + 15.8 30.1 + 30.1 + 30.1 + 28.6 30.1 + 30.1 + 30.1 + 30.1 Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Rated Water Flow LPM 192 + 192 + 192 + 96 192 + 192 + 192 + 135 192 + 192 + 192 + 192 Combination x No. (Inverter) x 1 (Inverter) x 1 (Inverter) x 1
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Motor Output x
Compressor W x No. 4,200 x 1 4,200 x 1 4,200 x 1
Combination x No. (Inverter) x 4 (Inverter) x 4 (Inverter) x 4 Number
Motor Output x Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Compressor W x No. 5,300 x 3 + 4,200 x 1 5,300 x 3 + 4,200 x 1 5,300 x 4
Number Oil Charge cc 2,800 2,800 2,800
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) Liquid Pipe mm (inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Ø 12.7 (1/2)
Oil Charge cc 11,800 11,800 12,000 Refrigerant
Low Pressure Gas Pipe mm (inch) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 25.4 (1)
Connecting Pipes
Refrigerant Liquid Pipe mm (inch) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8) High Pressure Gas Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4)
Connecting Pipes Gas Pipe mm (inch) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Inlet A (inch) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread)
40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) Water Connecting
Outlet A (inch) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread)
Inlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 Pipes
(Internal Thread) (Internal Thread) (Internal Thread) Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 1 (755 x 997 x 500) x 1 (755 x 997 x 500) x 1
Pipes Outlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40
(Internal Thread) (Internal Thread) (Internal Thread) Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 1 (804 x 1,143 x 630) x 1 (804 x 1,143 x 630) x 1
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) Net Weight kg x No. 127 x 1 127 x 1 127 x 1
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 4 (755 x 997 x 500) x 4 (755 x 997 x 500) x 4 Shipping Weight kg x No. 137 x 1 137 x 1 137 x 1
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4 Sound Pressure Cooling dB(A) 47.0 50.0 58.0
Net Weight kg x No. (140 x 3) + (127 x 1) (140 x 3) + (127 x 1) 140 x 4 Level Heating dB(A) 51.0 53.0 57.0
Shipping Weight kg x No. (150 x 3) + (137 x 1) (150 x 3) + (137 x 1) 150 x 4 Cooling dB(A) 59.0 62.0 70.0
Sound Power Level
Sound Pressure Cooling dB(A) 59.3 61.0 57.0 Heating dB(A) 63.0 65.0 69.0
Level Heating dB(A) 65.1 63.0 63.0 Communication mm2 x No.
1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
Cable (VCTF-SB)
Cooling dB(A) 71.3 75.0 71.0
Sound Power Level Refrigerant Name R410A R410A R410A
Heating dB(A) 77.1 77.0 77.0 Precharged Amount in
kg 5.8 5.8 5.8
Communication mm2 x No. Refrigerant Factory
1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
Cable (VCTF-SB) t-CO2 eq. 12.1 12.1 12.1
Refrigerant Name R410A R410A R410A
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Precharged Amount in
kg 14.8 14.8 12.0 Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Refrigerant Factory
t-CO2 eq. 30.9 30.9 25.1 Number of Maximum Connectable Indoor Units 1) 13 (20) 16 (25) 23 (35)
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 64 64 64

Note Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance 1. M
 aximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination(160% ~ 200%). The recommended ratio is 130%. with outdoor units combination(160% ~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification 2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions 3. Performances are based on the following conditions
- Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F) - Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F)
- Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F) - Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m. - Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms 4. S
 ound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation. by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A) 5. This product contains Fluorinated Greenhouse Gases. (R410A)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.) 6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)

092 / 093
OUTDOOR UNIT _ MULTI V WATER IV _ SPECIFICATION

MULTI V WATER IV HEAT RECOVERY MULTI V WATER IV HEAT RECOVERY

OUTDOOR
UNITS
ARWB200LAS4 / ARWB160LAS4 ARWB220LAS4 / ARWB240LAS4
ARWB180LAS4 ARWB280LAS4

MULTI V WATER IV
HP 20 16 18 HP 22 24 28
Combination Unit ARWB200LAS4 ARWB160LAS4 ARWB180LAS4 Combination Unit ARWB220LAS4 ARWB240LAS4 ARWB280LAS4
Model Name ARWB080LAS4 ARWB100LAS4 Model Name ARWB140LAS4 ARWB140LAS4 ARWB140LAS4
Independent Unit ARWB200LAS4 Independent Unit
ARWB080LAS4 ARWB080LAS4 ARWB080LAS4 ARWB100LAS4 ARWB140LAS4
Cooling (Rated) kW 56.0 44.8 50.4 Cooling (Rated) kW 61.6 67.2 78.4
Capacity Capacity
Heating (Rated) kW 63.0 50.4 56.7 Heating (Rated) kW 69.3 75.6 88.2
Cooling (Rated) kW 11.20 7.72 8.95 Cooling (Rated) kW 11.70 12.93 15.68
Input Input
Heating (Rated) kW 11.67 8.40 9.54 Heating (Rated) kW 12.37 13.51 16.34
EER 5.00 5.80 5.63 EER 5.26 5.20 5.00
COP Rated Capacity 5.40 6.00 5.94 COP Rated Capacity 5.60 5.60 5.40
Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray
Exterior Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure Maximum Pressure
kgf/cm2 45 45 45 kgf/cm2 45 45 45
Heat Exchanger Resistance Heat Exchanger Resistance
Head Loss kPa 30.1 10.7 + 10.7 15.8 + 10.7 Head Loss kPa 28.6 + 10.7 28.6 + 15.8 28.6 + 28.6
Rated Water Flow LPM 192 77 + 77 96 + 77 Rated Water Flow LPM 135 + 77 135 + 96 135 + 135
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 1 (Inverter) x 2 (Inverter) x 2 Combination x No. (Inverter) x 2 (Inverter) x 2 (Inverter) x 2
Motor Output x Motor Output x
Compressor W x No. 5,300 x 1 4,200 x 2 4,200 x 2 Compressor W x No. 4,200 x 2 4,200 x 2 4,200 x 2
Number Number
Oil Type FVC68D(PVE) FVC68D(PVE) FVC68D(PVE) Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 3,000 5,600 5,600 Oil Charge cc 5,600 5,600 5,600
Liquid Pipe mm (inch) Ø 12.7(1/2) Ø 12.7(1/2) Ø 12.7(1/2) Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4)
Refrigerant Refrigerant
Low Pressure Gas Pipe mm (inch) Ø 28.58(1-1/8) Ø 28.58(1-1/8) Ø 28.58(1-1/8) Low Pressure Gas Pipe mm (inch) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8)
Connecting Pipes Connecting Pipes
High Pressure Gas Pipe mm (inch) Ø 19.05(3/4) Ø 19.05(3/4) Ø 19.05(3/4) High Pressure Gas Pipe mm (inch) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8)
40A(PT 1-1/2) + 40A(PT 1-1/2) 40A(PT 1-1/2) + 40A(PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Inlet A (inch) 40A(PT 1-1/2) (Internal Thread) Inlet A (inch)
(Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread)
Water Connecting 40A(PT 1-1/2) + 40A(PT 1-1/2) 40A(PT 1-1/2) + 40A(PT 1-1/2) Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Pipes Outlet A (inch) 40A(PT 1-1/2) (Internal Thread) Pipes Outlet A (inch)
(Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread) (Internal Thread)
Drain Outlet A (inch) 20A(PT 3/4) (External Thread) 20A(PT 3/4) (External Thread) 20A(PT 3/4) (External Thread) Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 1 (755 x 997 x 500) x 2 (755 x 997 x 500) x 2 Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 2 (755 x 997 x 500) x 2 (755 x 997 x 500) x 2
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 1 (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2 Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2
Net Weight kg x No. 140 x 1 127 x 2 127 x 2 Net Weight kg x No. 127 x 2 127 x 2 127 x 2
Shipping Weight kg x No. 150 x 1 137 x 2 137 x 2 Shipping Weight kg x No. 137 x 2 137 x 2 137 x 2
Sound Pressure Cooling dB(A) 54.0 50.0 52.0 Sound Pressure Cooling dB(A) 58.0 59.0 59.0
Level Heating dB(A) 60.0 54.0 55.0 Level Heating dB(A) 58.0 58.0 58.0
Cooling dB(A) 66.0 62.0 64.0 Cooling dB(A) 70.0 71.0 72.0
Sound Power Level Sound Power Level
Heating dB(A) 72.0 66.0 67.0 Heating dB(A) 70.0 70.0 71.0
Communication mm2 x No. Communication mm2 x No.
1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
Cable (VCTF-SB) Cable (VCTF-SB)
Refrigerant Name R410A R410A R410A Refrigerant Name R410A R410A R410A
Precharged Amount in Precharged Amount in
kg 3.0 11.6 11.6 kg 11.6 11.6 11.6
Refrigerant Factory Refrigerant Factory
t-CO2 eq. 6.3 24.2 24.2 t-CO2 eq. 24.2 24.2 24.2
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 32(50) 26(40) 29(45) Number of Maximum Connectable Indoor Units 1) 35 (44) 39 (48) 45 (56)

Note Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance 1. M
 aximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination(160% ~ 200%). The recommended ratio is 130%. with outdoor units combination(160% ~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification 2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions 3. Performances are based on the following conditions
- Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F) - Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F)
- Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F) - Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m. - Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms 4. S
 ound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation. by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A) 5. This product contains Fluorinated Greenhouse Gases. (R410A)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.) 6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)

094 / 095
OUTDOOR UNIT _ MULTI V WATER IV _ SPECIFICATION

MULTI V WATER IV HEAT RECOVERY MULTI V WATER IV HEAT RECOVERY

OUTDOOR
UNITS
ARWB300LAS4 / ARWB340LAS4 ARWB420LAS4 / ARWB440LAS4
ARWB400LAS4 ARWB480LAS4

MULTI V WATER IV
HP 30 34 40 HP 42 44 48
Combination Unit ARWB300LAS4 ARWB340LAS4 ARWB400LAS4 Combination Unit ARWB420LAS4 ARWB440LAS4 ARWB480LAS4
Model Name ARWB200LAS4 ARWB200LAS4 ARWB200LAS4 ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
Independent Unit Model Name
ARWB100LAS4 ARWB140LAS4 ARWB200LAS4 Independent Unit ARWB140LAS4 ARWB140LAS4 ARWB140LAS4
Cooling (Rated) kW 84.0 95.2 112.0 ARWB080LAS4 ARWB100LAS4 ARWB140LAS4
Capacity Cooling (Rated) kW 117.6 123.2 134.4
Heating (Rated) kW 94.5 107.1 126.0 Capacity
Cooling (Rated) kW 16.29 19.04 22.40 Heating (Rated) kW 132.3 138.6 151.2
Input Cooling (Rated) kW 22.9 24.13 26.88
Heating (Rated) kW 17.01 19.84 23.34 Input
EER 5.16 5.00 5.00 Heating (Rated) kW 24.04 25.18 28.01

COP Rated Capacity 5.56 5.40 5.40 EER 5.14 5.11 5.00

Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray COP Rated Capacity 5.50 5.50 5.40
Exterior Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 Exterior
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Maximum Pressure Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
kgf/cm2 45 45 45
Heat Exchanger Resistance Maximum Pressure
kgf/cm2 45 45 45
Head Loss kPa 30.1 + 15.8 30.1 + 28.6 30.1 + 30.1 Heat Exchanger Resistance
Rated Water Flow LPM 192 + 96 192 + 135 192 + 192 Head Loss kPa 30.1 + 28.6 + 10.7 30.1 + 28.6 + 15.8 30.1 + 28.6 + 28.6

Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Rated Water Flow LPM 192 + 135 + 77 192 + 135 + 96 192 + 135 + 135

Combination x No. (Inverter) x 2 (Inverter) x 2 (Inverter) x 2 Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Motor Output x Combination x No. (Inverter) x 3 (Inverter) x 3 (Inverter) x 3
Compressor W x No. 5,300 x 1 + 4,200 x 1 5,300 x 1 + 4,200 x 1 5,300 x 2
Number Motor Output x
Compressor W x No. 5,300 x 1 + 4,200 x 2 5,300 x 1 + 4,200 x 2 5,300 x 1 + 4,200 x 2
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) Number
Oil Charge cc 5,800 5,800 6,000 Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)

Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) Oil Charge cc 8,600 8,600 8,600
Refrigerant Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4)
Low Pressure Gas Pipe mm (inch) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Ø 41.3 (1-5/8)
Connecting Pipes Refrigerant
High Pressure Gas Pipe mm (inch) Ø 28.58 (1-1/8) Ø 28.58 (1-1/8) Ø 34.9 (1-3/8) Low Pressure Gas Pipe mm (inch) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8)
Connecting Pipes
40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) High Pressure Gas Pipe mm (inch) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8)
Inlet A (inch)
(Internal Thread) (Internal Thread) (Internal Thread) 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) +
Water Connecting Inlet A (inch)
40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread)
Pipes Outlet A (inch) Water Connecting
(Internal Thread) (Internal Thread) (Internal Thread) 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) +
Pipes Outlet A (inch)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 2 (755 x 997 x 500) x 2 (755 x 997 x 500) x 2 Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)

Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2 Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 3 (755 x 997 x 500) x 3 (755 x 997 x 500) x 3

Net Weight kg x No. (140 x 1) + (127 x 1) (140 x 1) + (127 x 1) 140 x 2 Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3

Shipping Weight kg x No. (150 x 1) + (137 x 1) (150 x 1) + (137 x 1) 150 x 2 Net Weight kg x No. (140 x 1) + (127 X 2) (140 x 1) + (127 X 2) (140 x 1) + (127 X 2)

Cooling dB(A) 55.0 59.0 55.0 Shipping Weight kg x No. (150 x 1) + (137 X 2) (150 x 1) + (137 X 2) (150 x 1) + (137 X 2)
Sound Pressure
Level Heating dB(A) 61.0 61.0 61.0 Sound Pressure Cooling dB(A) 60.0 60.0 60.0
Level Heating dB(A) 62.0 62.0 62.0
Cooling dB(A) 67.0 72.0 68.0
Sound Power Level Cooling dB(A) 72.0 72.0 74.0
Heating dB(A) 73.0 74.0 74.0 Sound Power Level
Communication mm2 x No. Heating dB(A) 74.0 74.0 76.0
1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
Cable (VCTF-SB) Communication mm2 x No.
1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
Refrigerant Name R410A R410A R410A Cable (VCTF-SB)
Precharged Amount in Refrigerant Name R410A R410A R410A
kg 8.8 8.8 6.0
Refrigerant Factory Precharged Amount in
kg 14.6 14.6 14.6
t-CO2 eq. 18.4 18.4 12.5 Refrigerant Factory
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve t-CO2 eq. 30.5 30.5 30.5

Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve

Number of Maximum Connectable Indoor Units 1) 49 (60) 55 (64) 64 Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 64 64 64

Note Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance 1. M
 aximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination(160% ~ 200%). The recommended ratio is 130%. with outdoor units combination(160% ~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification 2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions 3. Performances are based on the following conditions
- Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F) - Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F)
- Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F) - Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m. - Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms 4. S
 ound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation. by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A) 5. This product contains Fluorinated Greenhouse Gases. (R410A)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.) 6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)

096 / 097
OUTDOOR UNIT _ MULTI V WATER IV _ SPECIFICATION

MULTI V WATER IV HEAT RECOVERY MULTI V WATER IV HEAT RECOVERY

OUTDOOR
UNITS
ARWB500LAS4 / ARWB540LAS4 ARWB620LAS4 / ARWB640LAS4
ARWB600LAS4 ARWB680LAS4

MULTI V WATER IV
HP 50 54 60 HP 62 64 68
Combination Unit ARWB500LAS4 ARWB540LAS4 ARWB600LAS4 Combination Unit ARWB620LAS4 ARWB640LAS4 ARWB680LAS4
Model Name ARWB200LAS4 ARWB200LAS4 ARWB200LAS4 ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
Independent Unit ARWB200LAS4 ARWB200LAS4 ARWB200LAS4 Model Name ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
Independent Unit
ARWB100LAS4 ARWB140LAS4 ARWB200LAS4 ARWB140LAS4 ARWB140LAS4 ARWB140LAS4
Cooling (Rated) kW 140.0 151.2 168.0 ARWB080LAS4 ARWB100LAS4 ARWB140LAS4
Capacity Cooling (Rated) kW 173.6 179.2 190.4
Heating (Rated) kW 157.5 170.1 189.0 Capacity
Heating (Rated) kW 195.3 201.6 214.2
Cooling (Rated) kW 27.49 30.24 33.60
Input Cooling (Rated) kW 34.10 35.33 38.08
Heating (Rated) kW 28.68 31.51 35.01 Input
Heating (Rated) kW 35.71 36.85 39.68
EER 5.09 5.00 5.00
EER 5.09 5.07 5.00
COP Rated Capacity 5.49 5.40 5.40
COP Rated Capacity 5.47 5.47 5.40
Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray
Exterior Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45 Maximum Pressure
Heat Exchanger Resistance kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 30.1 + 30.1 + 15.8 30.1 + 28.6 + 28.6 30.1 + 30.1 + 30.1
Head Loss kPa 30.1 + 30.1 + 28.6 + 10.7 30.1 + 30.1 + 28.6 + 15.8 30.1 + 30.1 + 28.6 + 28.6
Rated Water Flow LPM 192 + 192 + 96 192 + 192 + 135 192 + 192+ 192
Rated Water Flow LPM 192 + 192 + 135 + 77 192 + 192 + 135 + 96 192 + 192 + 135 + 135
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 3 (Inverter) x 3 (Inverter) x 3 Combination x No. (Inverter) x 4 (Inverter) x 4 (Inverter) x 4
Motor Output x Motor Output x
Compressor W x No. 5,300 x 2 + 4,200 x 1 5,300 x 2 + 4,200 x 1 5,300 x 3 Compressor W x No. 5,300 x 2 + 4,200 x 2 5,300 x 2 + 4,200 x 2 5,300 x 2 + 4,200 x 2
Number Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 8,800 8,800 9,000 Oil Charge cc 11,600 11,600 11,600
Liquid Pipe mm (inch) Ø 19.05 (3/4) Ø 19.05 (3/4) Ø 19.05 (3/4) Liquid Pipe mm (inch) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8)
Refrigerant Refrigerant
Low Pressure Gas Pipe mm (inch) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Low Pressure Gas Pipe mm (inch) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) Ø 53.98 (2-1/8)
Connecting Pipes Connecting Pipes
High Pressure Gas Pipe mm (inch) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) Ø 34.9 (1-3/8) High Pressure Gas Pipe mm (inch) Ø 41.3 (1-5/8) Ø 41.3 (1-5/8) Ø 44.5 (1-3/4)
40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Inlet A (inch)
40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) Inlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40
Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + (Internal Thread) (Internal Thread) (Internal Thread)
Pipes Outlet A (inch) Water Connecting
40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) Pipes Outlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40
(Internal Thread) (Internal Thread) (Internal Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 3 (755 x 997 x 500) x 3 (755 x 997 x 500) x 3
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 4 (755 x 997 x 500) x 4 (755 x 997 x 500) x 4
Net Weight kg x No. (140 x 2) + (127 X 1) (140 x 2) + (127 X 1) 140 x 3
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4
Shipping Weight kg x No. (150 x 2) + (137 X 1) (150 x 2) + (137 X 1) 150 x 3
Net Weight kg x No. (140 x 2) + (127 x 2) (140 x 2) + (127 x 2) (140 x 2) + (127 x 2)
Sound Pressure Cooling dB(A) 58.0 60.0 56.0
Shipping Weight kg x No. (150 x 2) + (137 x 2) (150 x 2) + (137 x 2) (150 x 2) + (137 x 2)
Level Heating dB(A) 63.0 62.0 62.0
Sound Pressure Cooling dB(A) 61.0 61.0 61.0
Cooling dB(A) 70.0 74.0 70.0 Level
Sound Power Level Heating dB(A) 64.0 64.0 63.0
Heating dB(A) 75.0 76.0 76.0
Cooling dB(A) 73.0 73.0 75.0
Communication mm2 x No. Sound Power Level
1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Heating dB(A) 76.0 76.0 77.0
Cable (VCTF-SB)
Refrigerant Name R410A R410A R410A Communication mm2 x No.
1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
Cable (VCTF-SB)
Precharged Amount in
kg 11.8 11.8 9.0 Refrigerant Name R410A R410A R410A
Refrigerant Factory
Precharged Amount in
t-CO2 eq. 24.6 24.6 18.8 kg 17.6 17.6 17.6
Refrigerant Factory
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve t-CO2 eq. 36.7 36.7 36.7
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Number of Maximum Connectable Indoor Units 1)
64 64 64 Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 64 64 64

Note Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance 1. M
 aximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination(160% ~ 200%). The recommended ratio is 130%. with outdoor units combination(160% ~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification 2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions 3. Performances are based on the following conditions
- Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F) - Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F)
- Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F) - Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m. - Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms 4. S
 ound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation. by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A) 5. This product contains Fluorinated Greenhouse Gases. (R410A)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.) 6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)

098 / 099
OUTDOOR UNIT _ MULTI V WATER IV _ SPECIFICATION

MULTI V WATER IV HEAT RECOVERY

OUTDOOR
UNITS
ARWB700LAS4 / ARWB740LAS4
ARWB800LAS4

MULTI V WATER IV
HP 70 74 80
Combination Unit ARWB700LAS4 ARWB740LAS4 ARWB800LAS4
ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
Model Name ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
Independent Unit
ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
ARWB100LAS4 ARWB140LAS4 ARWB200LAS4
Cooling (Rated) kW 196.0 207.2 224.0
Capacity
Heating (Rated) kW 220.5 233.1 252.0
Cooling (Rated) kW 38.69 41.44 44.80
Input
Heating (Rated) kW 40.35 43.18 46.68
EER 5.07 5.00 5.00
COP Rated Capacity 5.46 5.40 5.40
Color Warm Gray / Mornig Gray Warm Gray / Mornig Gray Warm Gray / Mornig Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 30.1 + 30.1 + 30.1 + 15.8 30.1 + 30.1 + 30.1 + 28.6 30.1 + 30.1 + 30.1 + 30.1
Rated Water Flow LPM 192 + 192 + 192 + 96 192 + 192 + 192 + 135 192 + 192 + 192 + 192
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 4 (Inverter) x 4 (Inverter) x 4
Motor Output x
Compressor W x No. 5,300 x 3 + 4,200 x 1 5,300 x 3 + 4,200 x 1 5,300 x 4
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 11,800 11,800 12,000
Liquid Pipe mm (inch) Ø 22.2 (7/8) Ø 22.2 (7/8) Ø 22.2 (7/8)
Refrigerant
Low Pressure Gas Pipe mm (inch) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8) Ø 53.98 (2-1/8)
Connecting Pipes
High Pressure Gas Pipe mm (inch) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4) Ø 44.5 (1-3/4)
40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Inlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40
(Internal Thread) (Internal Thread) (Internal Thread)
Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Pipes Outlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40
(Internal Thread) (Internal Thread) (Internal Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 4 (755 x 997 x 500) x 4 (755 x 997 x 500) x 4
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4
Net Weight kg x No. (140 x 3) + (127 x 1) (140 x 3) + (127 x 1) 140 x 4
Shipping Weight kg x No. (150 x 3) + (137 x 1) (150 x 3) + (137 x 1) 150 x 4
Sound Pressure Cooling dB(A) 59.0 61.0 57.0
Level Heating dB(A) 65.0 63.0 63.0
Cooling dB(A) 71.0 75.0 71.0
Sound Power Level
Heating dB(A) 77.0 77.0 77.0
Communication mm2 x No.
1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
Cable (VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 14.8 14.8 12.0
Refrigerant Factory
t-CO2 eq. 30.9 30.9 25.1
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 64 64 64

Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination(160% ~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp. 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp. 30°C (86°F)
- Heating : Indoor temp. 20°C (68°F) DB, Water inlet temp. 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)

100 / 101
INDOOR

INDOOR
UNITS
UNITS

WALL MOUNTED / CEILING MOUNTED CASSETTE /

CEILING MOUNTED ROUND CASSETTE /

CEILING CONCEALED DUCT / FRESH AIR INTAKE /

CEILING & FLOOR CONVERTIBLE / CEILING SUSPENDED /

CONSOLE & FLOOR STANDING / COMPATIBILITY /

FEATURE FUNCTIONS

102 / 103
INDOOR UNIT _ WALL MOUNTED UNIT INDOOR UNIT _ WALL MOUNTED UNIT _ KEY FEATURES

SMART
Wi-Fi Control
WALL MOUNTED Anytime, anywhere access to the unit with Android & iOS-based smartphones.

UNIT

INDOOR
LG ThinQ

UNITS
Search “LG ThinQ” on Google market or the App Store to download the app.
LG ThinQ

Integrated Home Appliances Control Access your air conditioner anytime and from anywhere
Control / Monitor all your LG appliances from one place. with a Wi-Fi equipped device and LG’s exclusive control app, Smart ThinQ.

WALL MOUNTED UNIT


Easy Registration and Log-in
Follow the easy set-up steps that will activate LG ThinQ’s user-friendly features. Wi-Fi Connectivity
Each user can set and save temperature and fan speed preferences in
the LG ThinQ app. If a household has more than one indoor unit, separate
temperature settings can be set for each.

Multiple Devices

Features & Benefits Key Applications


• 6 different discharge angles can be programmed via the remote controller. • Retail • Hotel Simple operation for various functions
• Easily detachable full surface cover helps to clean the air conditioner. • Restaurant • Multi-family Residence
• Drain pipe can be easily hidden from sight. • Office * Can be controlled by multiple users, but not simultaneously.

Multi-Control
Wall Mounted Unit Artcool Mirror Artcool Gallery Standard
Smart Wi-Fi ○ ○ ○
Energy Efficiency Energy Display ○ ○ ○
On/Off, Current Temp Mode, Set Temp Vane Control
Fast Cooling & Jet Cool ○ ○ ○
Heating Auto Swing (up & down) ○ ○ ○
○ Straight forward Management
Ionizer ○ -
~7.1kW Only
Health Pre Filter ○ ○ ○
Auto Cleaning ○ ○ ○
Sleep Mode ○ ○ ○
Timer (on / off) ○ ○ ○
Comfort Timer (weekly) ○ ○ ○
Two Thermistor Control ○ ○ ○
Group Control ○ ○ ○ Reservation Energy Smart Filter
Monitoring Diagnosis Management
※ ○: Applied, - : Not applied

104 / 105
INDOOR UNIT _ WALL MOUNTED UNIT _ KEY FEATURES

FRESH AIR FAST COOLING & HEATING COMFORT


Ionizer PLUS Cleans Filter with Regular Airflow Auto Swing Scheduled Operation
The comprehensive auto cleaning function prevents the formation of bacteria
The powerful Ionizer protects you from bad odors and Cool air extends to the entire room regardless of where You can set the daily temperature, fan speed, the operation
and mold on the heat exchanger.
ilizes Over Escherichia
3 Million coliIons)
and Staphylococcus in the surface with over the unit is situated. mode and automatic on/off time for two weeks. It will
3 million ions to sterilize to make a safer, and cleaner
particles by infusing the air passing through the air conditioner with over 3 millions ions. How It Works
* Specifications may vary for each model. keep running on that time until cancelled by the user.
environment.

INDOOR
UNITS
* Specifications may vary for each model.
6-step Vane,
6-Step Vane Control up to
Control up to 70°
70° 5-Step Louver, Control
* This function upremote
is for wired to 55°
controller only.
* Depending on the experimental conditions. H H The
Thevertical vane,
vertical which
vane, moves
which up andup
moves down,
andhas 6 different
down, has 6settings including
different full-auto swing.
settings * Wired
The louver, which remote
sways leftcontroller
and right,ishas
need to be separately
5 different settingspurchased.
including full auto-swing.
H H
H H
O- including full-auto swing.
H+ Sterilization and Deodorization (Utilizes Over 3 Million Ions) Schedule 1 Schedule 2
O- Ionizer+ reduces E.coli and Staphylococcus in the surface with over Setting temperature : 19℃ Setting temperature : 21℃
By dehumidifying, (some models are by Operation time : 09:00 ~ 12:00 Operation time : 13:00 ~ 18:00
H+ 3 million ions.

WALL MOUNTED UNIT


O- dehumififying and ionizing), the auto cleaning
function prevents potentially harmful substances
1
from forming on the surface of the heat exchanger.
How It Works Up & Down 2
rmful Substances OH Radical Production Chemical Reaction Complete
Cleans Filter with Sterilization
Regular Airflow 70° 3
harmful particles Ion Cluster OH Surrounding
radicles inactivate OH
harmful 4
Radicalsubstances OH radicles
Chemical Reaction bond with H particles inThe
Sterilization thecomprehensive
air Hauto
2O molecules are produced
cleaning function prevents the formation of bacteria and mold on the heat exchanger, providing a more pleasant and comfortable environment. Heating 5
Generation
Ions are released
Harmful Substances Production
H- and O- bond to How It Works
OH radicles inactivate OH radicles bond H2O molecules are
6
into air
2
harmful particles harmful substances with H particles
H H
produced How It Works * Angle can be different from each model and working mode. 9:00 12:00 13:00 18:00
Cleans Filter withHRegular
H H
H Airflow
Sterilization Performance Evaluations 6-Step Vane, Control up to 70°
The comprehensive auto cleaning function prevents the formation of bacteria and mold on the heat exchanger, providing a more pleasant and comfortable environment. Control
5-Step up toControl
Louver, 110° up to 55°
The vertical vane, which moves up and down, has 6 different settings including full-auto swing.
TheLouver
louver, can
whichbesways left and right, hasto5 extend
differentleft
settings
and including full auto-swing.
Sterilize Bacteria E.coli over 99.9% in 30 min. and staphylococcus over
The indoor environment remains odorless By preventing pollution of the heat 110 degrees.
adjusted manually right swing to
Two Thermistors Control
99.6% in 60min. * Test Conditions : with the advanced deodorizing function. exchanger caused by various germs and The indoor temperature can be checked using the
Space : 5 2m3 Chamber (measuring
By eliminating the humidity and bacteriabacteria,
left in the performance and lifespan
The indoor environment of the with
remains odorless air the By preventing the polluting of the heat exchangerBenefit
Survival Rate Virus Bacteria (%)

100
2 H
H Hwith the specimen in the
H
center of test chamber)
air conditioner, the auto cleaning function removes advanced deodorizing function.
conditioner can be increased over 10 years. by various germs and bacteria, the cooling performance thermistors in the remote controller as well as from the
H H all substances that might be harmful to human body. and longevity ofthe air conditioner remains unchanged
80 Temperature & Humidity : Normal even after 10 years of usage.
4 Way Swing indoor unit. There may be a significant difference between
60 Pain Point Bacteria E.coli
Bacteria : E coil colon bacillus,
Staphylococcus Aureus Certificate
Benefit ceiling and floor air temperature. Two thermistors can
4 Way Swing disperses cool air quickly and effectively in multiple directions to each corner of a room.
99.9% Tested by Intertek Auto cleaning
40
2.1 odor strength decrease in 60 minutes Air conditioners with
Sanitization
vanes that only move
By eliminating
up and
staphylococcus
down are Removes
Auto Harmful Particles
Intertek, Verification Certifying Antibacterial
the humidity and bacteria left in the TheCleaning
indoor environment
provides remains odorless
clean withpreventing
air by the By preventing the polluting
bacteria, mold of the
andheat exchanger
odors that Left & Right optimise indoor air temperature for a more comfortable
20 unable to suitably cool all areas of aairroom.
conditioner, the auto cleaning function removes Auto Cleaning deodorizing
advancedprovides cleanfunction.
air by eliminating bacteria, moldbyand
various
odorsgerms andotherwise
that can bacteria, the cooling performance
accumulate in an indoor unit.
30 min.
99.9%
An odor of strength 2 or less indicates that there is odor but no sense
all substances that might be harmful to human body.
Sanitization
Function of Plasmaster Ionizer+ / Ionizer
can otherwise accumulate in an indoor unit. and longevity ofthe air conditioner remains unchanged
even after 10 years of usage.
110° environment.
Heating /
of displeasure
0 (degree of odor permissible).
Benefit Cooling
d and bacteria growing on 15 30 45 60 Time (min)
* Angle can be different from each model and working mode.
he heat exchanger is wet. Removes Harmful Particles
2.1
Odor
odor strength decrease
Autoin 60 minutes
Cleaning provides clean air by eliminating bacteria, mold and odors that can otherwise accumulate in an indoor unit. Easy and Simple Control Indoor Unit
1 2 3 4
Strength
An odor of measured as 2 European odor units (ouE/m³) or less Thermistor
Airflow direction can be changed
indicates that the level of odor falls within permissible limits.
by LG ThinQ Wi-Fi app.
Normal Odor Strength 1 2 3 4
reus Offensive
odor Benefit Bacteria Elimination Odor Elimination Mold Elimination
substance
Offensive
sensitivity odor
4 Way Swing
substance
Mountain
smell
Indoor life
smell
Bathroom
smell
Food waste
smell
How It Works
sensitivity Mountain Indoor life Bathroom Food waste 4 Way Swing disperses cool air quickly and effectively in multiple directions to each corner of a room.
smell smell smell smell Up / Down Swing
and down are Odor strength Light Moderate Strong Very Strong Cleans Filter with Regular Airflow Remote Controller
level Thermistor
Odor strength level Light Moderate Strong Very Strong The comprehensive auto cleaning function prevents the formation of bacteria and mold on the heat exchanger, providing a more pleasant and comfortable environment.
Bacteria
Bacteria Elimination Odor Odor
Elimination MoldMold
Elimination Jet Cool
1.5 3.6 Prevention Elimination Elimination
LG air conditioners provide optimized high-speed airflow,
Odor strength reduce 3.6 1.5 / The Odor floating in the room as well as curtain and clothes. which can cool rooms faster while delivering cool air evenly Group Control
60
me(min)
Odor*strength reduce 3.6
Test conditions : 1.5 / The Odor floating in the room as well as curtain and clothes. in every direction. Group control by new remote controller (PREMTB100/
Space: 8m3 Chamber
Temperature & Humidify : Normal * Specifications may vary for each model.
Tested by Intertek * Depending on the experimental conditions. PREMTBB10) has more functions than previous model.
INSTALLATION One Click “Jet Mode”
Auto Cleaning Installation Support
By eliminating the humidity and bacteria left in the The indoor environment remains odorless with the
Clip
air conditioner, the auto cleaning function removes advanced deodorizing function.
By preventing
Reduces thetemperature
the polluting of theof
heat exchanger air to 18°C for 30 minutes with
outflowing
by various germs and bacteria, the cooling performance
The unit has a self-cleaning funtion that dries the heat all substances that might be harmful to human body. just
and one click.
longevity ofthe air conditioner remains unchanged
A support clip creates adequate space between the wall and the unit for even after 10 years of usage.
exchanger before sterilizing the interior. easier installation.
Benefit
Cooling / Heating Dehumidification
Removes Harmful Particles Fan only operating Setting temp.
Pain Point 25°
Auto Cleaning provides clean air by eliminating bacteria, mold and odors that can otherwise accumulate in an indoor unit.
The main cause of odor within air conditioners is mold and bacteria
growing on the heat exchanger. These germs can spread when the heat Standard Operation
exchanger is wet.
ng on
wet. More Powerful Performance In Case of Group Control
By reducing the second vortex, which
decreases airflow within the air outlet,
and enlarging the fan size, the amount of
167mm
air flow is increased to 13 CMM.

Low Magnitude of High


Velocity
Bacteria Elimination Odor Elimination Mold Elimination

106 / 107
INDOOR UNIT _ WALL MOUNTED UNIT _ SPECIFICATION

ARTCOOL MIRROR ARTCOOL MIRROR


ARNU05GSJR4 / ARNU07GSJR4 ARNU18GSKR4 / ARNU24GSKR4
ARNU09GSJR4 / ARNU12GSJR4
ARNU15GSJR4

INDOOR
UNITS
WALL MOUNTED UNIT
Model Unit ARNU05GSJR4 ARNU07GSJR4 ARNU09GSJR4 ARNU12GSJR4 ARNU15GSJR4 Model Unit ARNU18GSKR4 ARNU24GSKR4
Cooling Capacity kW 1.6 2.2 2.8 3.6 4.5 Cooling Capacity kW 5.6 7.1
Heating Capacity kW 1.8 2.5 3.2 4.0 5.0 Heating Capacity kW 6.3 7.5
Power Input Power Input
Nominal W 11 / 10 / 9 12 / 11 / 9 13 / 12 / 9 15 / 13 / 11 23 / 18 / 11 Nominal W 32 / 26 / 16 39 / 26 / 16
(H / M / L) (H / M / L)
Exterior Color Mirror (Black) Mirror (Black) Mirror (Black) Mirror (Black) Mirror (Black) Exterior Color Mirror (Black) Mirror (Black)
RAL Code RAL 9005 RAL 9005 RAL 9005 RAL 9005 RAL 9005 RAL Code RAL 9005 RAL 9005
Dimensions Body mm 837 x 308 x 192 837 x 308 x 192 837 x 308 x 192 837 x 308 x 192 837 x 308 x 192 Dimensions Body mm 998 x 345 x 212 998 x 345 x 212
(W x H x D) Shipping mm 909 x 383 x 256 909 x 383 x 256 909 x 383 x 256 909 x 383 x 256 909 x 383 x 256 (W x H x D) Shipping mm 1,080 x 422 x 281 1,080 x 422 x 281
Type Cross Flow Fan Cross Flow Fan Cross Flow Fan Cross Flow Fan Cross Flow Fan Type Cross Flow Fan Cross Flow Fan
Motor Output x Number W x No. 30 x 1 30 x 1 30 x 1 30 x 1 30 x 1 Motor Output x Number W x No. 58 x 1 58 x 1
Fan Fan
Air Flow Rate (H / M / L) m³/min 6.8 / 6.5 / 5.9 7.2 / 6.8 / 5.9 7.8 / 7.2 / 5.9 8.5 / 7.8 / 6.8 10.5 / 9.5 / 6.8 Air Flow Rate (H / M / L) m³/min 14.0 / 12.0 / 10.5 15.2 / 12.7 / 10.5
Motor Type BLDC BLDC BLDC BLDC BLDC Motor Type BLDC BLDC
Air Filter Pre Filter Pre Filter Pre Filter Pre Filter Pre Filter Air Filter Pre Filter Pre Filter
Liquid Side mm (inch) Ø6.35 (1/4) Ø6.35 (1/4) Ø6.35 (1/4) Ø6.35 (1/4) Ø6.35 (1/4) Liquid Side mm (inch) Ø6.35 (1/4) Ø9.52 (3/8)
Pipe Pipe
Gas Side mm (inch) Ø12.7 (1/2) Ø12.7 (1/2) Ø12.7 (1/2) Ø12.7 (1/2) Ø12.7 (1/2) Gas Side mm (inch) Ø12.7 (1/2) Ø15.88 (5/8)
Connections Connections
Drain Pipe (Internal Dia.) mm (inch) Ø16 (5/8) Ø16 (5/8) Ø16 (5/8) Ø16 (5/8) Ø16 (5/8) Drain Pipe (Internal Dia.) mm (inch) Ø16(5/8) Ø16 (5/8)
Weight Body kg 9.2 9.2 9.2 9.2 9.2 Weight Body kg 13.4 13.4
Sound Pressure Levels (H / M / L) dB(A) 30 / 29 / 28 32 / 30 / 28 34 / 32 / 28 37 / 34 / 30 42 / 39 / 32 Sound Pressure Levels (H / M / L) dB(A) 43 / 39 / 34 46 / 41 / 34
Sound Power Levels (H / M / L) dB(A) 54 / 53 / 52 54 / 53 / 52 55 / 54 / 52 55 / 54 / 53 58 / 56 / 54 Sound Power Levels (H / M / L) dB(A) 63 / 57 / 54 65 / 60 / 54
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50
Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C

Note : 1. Performance tested under EN14511 Note : 1. Performance tested under EN14511
2. Capacities are based on the following conditions 2. Capacities are based on the following conditions
- Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero
3. Due to our policy of innovation, some specifications may be changed without notification 3. Due to our policy of innovation, some specifications may be changed without notification

Accessories Accessories
Chassis ARNU05GSJR4 ARNU07GSJR4 ARNU09GSJR4 ARNU12GSJR4 ARNU15GSJR4 Chassis ARNU18GSKR4 ARNU24GSKR4
Drain Pump - Drain Pump -
Cassette Cover - Cassette Cover -
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
EEV Kit PRGK024A0 EEV Kit PRGK024A0
Independent Power Module PRIP0 Independent Power Module PRIP0
Robot Cleaner - Robot Cleaner -
Pre Filter (washable) ○ Pre Filter (washable) ○
Ion Generator ○ Ion Generator ○
CO2 Sensor - CO2 Sensor -
Ventilation Kit - Ventilation Kit -
IR Receiver - IR Receiver -
Zone Controller - Zone Controller -
PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible), PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible),
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus) PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus)
External Input (1 point) ○ External Input (1 point) ○
Wi-Fi ○ Wi-Fi ○

※ ○ : Applied, - : Not applied ※ ○ : Applied, - : Not applied


Option : Refer to model name in table Option : Refer to model name in table
1) Available from April 2020 1) Available from April 2020

108 / 109
INDOOR UNIT _ WALL MOUNTED UNIT _ SPECIFICATION

ARTCOOL GALLERY STANDARD


ARNU07GSF14 / ARNU09GSF14 ARNU05GSJ*4 / ARNU07GSJ*4
ARNU12GSF14 ARNU09GSJ*4 / ARNU12GSJ*4
ARNU15GSJ*4

INDOOR
UNITS
WALL MOUNTED UNIT
Model Unit ARNU07GSF14 ARNU09GSF14 ARNU12GSF14 Model Unit ARNU05GSJ*4 ARNU07GSJ*4 ARNU09GSJ*4 ARNU12GSJ*4 ARNU15GSJ*4
Cooling Capacity kW 2.2 2.8 3.6 Cooling Capacity kW 1.6 2.2 2.8 3.6 4.5
Heating Capacity kW 2.5 3.2 4.0 Heating Capacity kW 1.8 2.5 3.2 4.0 5.0
Power Input Power Input
Nominal W 28 / 16 / 10 28 / 16 / 10 32 / 20 / 12 Nominal W 11 / 10 / 9 12 / 11 / 9 13 / 12 / 9 15 / 13 / 11 23 / 18 / 11
(H / M / L) (H / M / L)
Dimensions Body mm 600 x 600 x 146 600 x 600 x 146 600 x 600 x 146 Exterior Color White White White White White
(W x H x D) Shipping mm 685 x 670 x 215 685 x 670 x 215 685 x 670 x 215 RAL Code RAL 9016 RAL 9016 RAL 9016 RAL 9016 RAL 9016
Type Turbo Fan Turbo Fan Turbo Fan Dimensions Body mm 818 x 316 x 189 818 x 316 x 189 818 x 316 x 189 818 x 316 x 189 818 x 316 x 189
Motor Output x Number W x No. 30 x 1 30 x 1 30 x 1 (W x H x D) Shipping mm 892 x 381 x 249 892 x 381 x 249 892 x 381 x 249 892 x 381 x 249 892 x 381 x 249
Fan
Air Flow Rate (H / M / L) m³/min 8.1 / 6.3 / 4.2 8.1 / 6.3 / 4.2 9.3 / 7.7 / 6.0 Type Cross Flow Fan Cross Flow Fan Cross Flow Fan Cross Flow Fan Cross Flow Fan
Motor Type BLDC BLDC BLDC Motor Output x Number W x No. 30 x 1 30 x 1 30 x 1 30 x 1 30 x 1
Fan
Air Filter Pre Filter Pre Filter Pre Filter Air Flow Rate (H / M / L) m³/min 6.8 / 6.5 / 5.9 7.2 / 6.8 / 5.9 7.8 / 7.2 / 5.9 8.5 / 7.8 / 6.8 10.5 / 9.5 / 6.8
Liquid Side mm (inch) Ø6.35 (1/4) Ø6.35 (1/4) Ø6.35 (1/4) Motor Type BLDC BLDC BLDC BLDC BLDC
Pipe
Gas Side mm (inch) Ø12.7 (1/2) Ø12.7 (1/2) Ø12.7 (1/2) Air Filter Pre Filter Pre Filter Pre Filter Pre Filter Pre Filter
Connections
Drain Pipe (Internal Dia.) mm (inch) Ø12 (15/32) Ø12 (15/32) Ø12 (15/32) Liquid Side mm (inch) Ø6.35 (1/4) Ø6.35 (1/4) Ø6.35 (1/4) Ø6.35 (1/4) Ø6.35 (1/4)
Pipe
Weight Body kg 15.0 15.0 15.0 Gas Side mm (inch) Ø12.7 (1/2) Ø12.7 (1/2) Ø12.7 (1/2) Ø12.7 (1/2) Ø12.7 (1/2)
Connections
Sound Pressure Levels (H / M / L) dB(A) 38 / 32 / 27 38 / 32 / 27 44 / 38 / 32 Drain Pipe (Internal Dia.) mm (inch) Ø16 (5/8) Ø16 (5/8) Ø16 (5/8) Ø16 (5/8) Ø16 (5/8)
Sound Power Levels (H / M / L) dB(A) 48 / 46 / 41 48 / 46 / 41 54 / 46 / 38 Weight Body kg 8.4 8.4 8.4 8.4 8.4
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 Sound Pressure Levels (H / M / L) dB(A) 30 / 29 / 28 32 / 30 / 28 34 / 32 / 28 37 / 34 / 30 42 / 39 / 32
Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Sound Power Levels (H / M / L) dB(A) 54 / 53 / 52 54 / 53 / 52 55 / 54 / 52 55 / 54 / 53 58 / 56 / 54
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
Note : 1. Performance tested under EN14511
2. Capacities are based on the following conditions Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
- Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero * : N or C can be applied which has little bit different shape of panel.
3. Due to our policy of innovation, some specifications may be changed without notification Note : 1. Performance tested under EN14511
2. Capacities are based on the following conditions
- Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero
3. Due to our policy of innovation, some specifications may be changed without notification

Accessories Accessories
Chassis ARNU07GSF14 ARNU09GSF14 ARNU12GSF14 Chassis ARNU05GSJ*4 ARNU07GSJ*4 ARNU09GSJ*4 ARNU12GSJ*4 ARNU15GSJ*4
Drain Pump - Drain Pump -
Cassette Cover - Cassette Cover -
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
EEV Kit PRGK024A0 EEV Kit PRGK024A0
Independent Power Module PRIP0 Independent Power Module PRIP0
Robot Cleaner - Robot Cleaner -
Pre Filter (washable) ○ Pre Filter (washable) ○
Ion Generator - Ion Generator ○
CO2 Sensor - CO2 Sensor -
Ventilation Kit - Ventilation Kit -
IR Receiver - IR Receiver -
Zone Controller - Zone Controller -
PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible), PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible),
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus) PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus)
External Input (1 point) ○ External Input (1 point) ○
Wi-Fi PWFMDD2002) Wi-Fi ○

※ ○ : Applied, - : Not applied ※ ○ : Applied, - : Not applied


Option : Refer to model name in table Option : Refer to model name in table
1) Available from April 2020 1) Available from April 2020
2) External installation only

110 / 111
INDOOR UNIT _ WALL MOUNTED UNIT _ SPECIFICATION

STANDARD STANDARD
ARNU18GSK*4 / ARNU24GSK*4 ARNU30GSVA4 / ARNU36GSVA4

INDOOR
UNITS
WALL MOUNTED UNIT
Model Unit ARNU18GSK*4 ARNU24GSK*4 Model Unit ARNU30GSVA4 ARNU36GSVA4
Cooling Capacity kW 5.6 7.1 Cooling Capacity kW 8.8 10.4
Heating Capacity kW 6.3 7.5 Heating Capacity kW 9.4 10.8
Power Input Power Input
Nominal W 32 / 26 / 16 39 / 26 / 16 Nominal W 54 / 43 / 31 85 / 51 / 36
(H / M / L) (H / M / L)
Exterior Color White White Exterior Color White White
RAL Code RAL 9016 RAL 9016 RAL Code RAL 9016 RAL 9016
Dimensions Body mm 975 x 354 x 209 975 x 354 x 209 Dimensions Body mm 1,190 x 346 x 265 1,190 x 346 x 265
(W x H x D) Shipping mm 1,063 x 420 x 274 1,063 x 420 x 274 (W x H x D) Shipping mm 1,265 x 432 x 335 1,265 x 432 x 335
Type Cross Flow Fan Cross Flow Fan Type Cross Flow Fan Cross Flow Fan
Motor Output x Number W x No. 58 x 1 58 x 1 Motor Output x Number W x No. 113 x 1 113 x 1
Fan Fan
Air Flow Rate (H / M / L) m³/min 14.0 / 12.0 / 10.5 15.2 / 12.7 / 10.5 Air Flow Rate (H / M / L) m³/min 23.0 / 20.0 / 17.0 26.0 / 23.0 / 19.0
Motor Type BLDC BLDC Motor Type BLDC BLDC
Air Filter Pre Filter Pre Filter Air Filter Pre Filter Pre Filter
Liquid Side mm (inch) Ø6.35 (1/4) Ø9.52 (3/8) Liquid Side mm (inch) Ø9.52 (3/8) Ø9.52 (3/8)
Pipe Pipe
Gas Side mm (inch) Ø12.7 (1/2) Ø15.88 (5/8) Gas Side mm (inch) Ø15.88 (5/8) Ø15.88 (5/8)
Connections Connections
Drain Pipe (Internal Dia.) mm (inch) Ø16 (5/8) Ø16 (5/8) Drain Pipe (Internal Dia.) mm (inch) Ø16 (5/8) Ø16 (5/8)
Weight Body kg 12.2 12.2 Weight Body kg 16.6 16.6
Sound Pressure Levels (H / M / L) dB(A) 43 / 39 / 34 46 / 41 / 34 Sound Pressure Levels (H / M / L) dB(A) 49 / 44 / 42 52 / 47 / 43
Sound Power Levels (H / M / L) dB(A) 63 / 57 / 54 65 / 60 / 54 Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
Note : 1. Performance tested under EN14511
* : N or C can be applied which has little bit different shape of panel. 2. Capacities are based on the following conditions
Note : 1. Performance tested under EN14511 - Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
2. Capacities are based on the following conditions - Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero
- Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero 3. Due to our policy of innovation, some specifications may be changed without notification
- Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero
3. Due to our policy of innovation, some specifications may be changed without notification

Accessories Accessories
Chassis ARNU18GSK*4 ARNU24GSK*4 Chassis ARNU30GSVA4 ARNU36GSVA4
Drain Pump - Drain Pump -
Cassette Cover - Cassette Cover -
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
EEV Kit PRGK024A0 EEV Kit -
Independent Power Module PRIP0 Independent Power Module PRIP0
Robot Cleaner - Robot Cleaner -
Pre Filter (washable) ○ Pre Filter (washable) ○
Ion Generator ○ Ion Generator -
CO2 Sensor - CO2 Sensor -
Ventilation Kit - Ventilation Kit -
IR Receiver - IR Receiver -
Zone Controller - Zone Controller -
PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible), PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible),
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus) PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus)
External Input (1 point) ○ External Input (1 point) ○
Wi-Fi ○ Wi-Fi PWFMDD2002)

※ ○ : Applied, - : Not applied ※ ○ : Applied, - : Not applied


Option : Refer to model name in table Option : Refer to model name in table
1) Available from April 2020 1) Available from April 2020
2) External installation only

112 / 113
INDOOR UNIT _ CEILING MOUNTED CASSETTE INDOOR UNIT _ CEILING MOUNTED CASSETTE _ KEY FEATURES

NEW DESIGN
4-way Air Flow with New Design Wide Design
CEILING MOUNTED New Excellent Technology (NET) certifies new 4-way dual vane Bigger inlet and outlet make faster cooling / heating airflow.
design that promotes comfortable and convienient airflow.
CASSETTE

INDOOR
UNITS
4-way
Dual Vane Increased Inlet Area

Normal 4Way

CEILING MOUNTED CASSETTE


x2

Dual Vane 4Way

*New types wind


Normal Dual Vane
Full 3D Turbo Fan
Full 3D Turbo fan decreases air resistance,
so it makes High Efficient and reduces noise level
Indirect
Wind Turbo fan

Direct
Wind

Full 3D Turbo fan


*6 Airflows mode Power consumption 13W ↓, Noise 3dB(A) ↓

Fast and Quick Fresh and Natural Auto Vane Control


Power Mode Up / Down Swing Smart Mode

Improved outlet flow rate

5m
Features & Benefits Key Applications High Efficiency Heat Exchanger (HEX)
• New dual vane 4 way cassette allows comfortable air flow • Retail Indirect cooling & Heating Suitable for High Ceiling Provide high concentration
Indirect Wind Direct Wind Refresh Mode
Ø5 High Density Heat Exchanger increases cooling
• Full 3D Turbo fan decreases air resistance, providing high air flow and • School / heating efficiency by 10%.
low sound levels. • Office
Normal Ø7 HEX
• Hotel
Brighter Color
• Dormitory
• Restaurant Color enhancement allows cassette to blend in to most
interior ceiling spaces. 20mm

Cassette 4 Way 2 Way 1 Way Normal Ivory Dual Vane White


Smart Wi-Fi ○ ○ ○ Tube Column 12 Column
Energy Efficiency Human Detect Sensor ○ - - 12 Column
Fin per Inch 21
Drain Pump ○ ○ ○
Sleep Mode ○ ○ ○
High Efficient Ø5 HEX
Timer (on / off) ○ ○ ○
Comfort
Timer (weekly) ○ ○ ○
Two Thermistor Control ○ ○ ○
Group Control ○ ○ ○ 14mm

Tube Column 18 Column


18 Column Fin per Inch 22

114 / 115
INDOOR UNIT _ CEILING MOUNTED CASSETTE _ KEY FEATURES

SMART SMART INSTALLATION


Ceiling to Floor Temperature Sensing High-performance Air Cleaning Air Cleaning Status Display Minimized Height
With a height of 132mm, the LG 1-Way Cassette is the ideal
With a special sensor that sense both ceiling and floor Air cleaning function provides fresh, filtered air. Wi-Fi functionality for anytime, anywhere indoor unit
solution for limited-space installations.
temperature, dual vane 4 way cassette provides comfort air control and air cleaning status display.
① IDU LED ② Remote controller

INDOOR
UNITS
IDU Temperature Real-time indoor air quality status Fine dust concentration & air quality
displayed on indoor unit status displayed on remote control
132mm

CEILING MOUNTED CASSETTE


Good Bad
Calculate Room
Temperature Normal Very Bad

Size Comparison (Unit : mm)


③ Mobile
Anytime, anywhere access to check A Company B Company LG
Floor Temperature
& control air status via mobile
1 Way
215 230 132
Cassette
※ Available only for products with floor temperature sensor..

Human-detection Air Flow


Flexible Installation
Human detection provides users with direct or indirect air 1 way cassette doesn’t require the inspection access hole,
flow preferences. so that simple installation is possible.
Indirect comfort Direct cooling
Dual Elevating Grille
1 Way cassette Duct
Provides air flow that blows away
from user for comfort.
Provides air flow that blows directly
onto user for cooling. Convenient & Powerful 5-step Air Grille automatically detaches and re-attaches with 4 touchpoints
for enhanced stability & convenient filter management. Duct
Cleaning
Normal 4way Smart Dual Vane IDU
Easy-to-manage air cleaning system with one-touch air
cleaning filter.
Inspection hole

No touch Direct airflow


Indirect airflow 4m
2°C
Comfort Cooler

Installation Standard
① Horizontal Sensor ② Check Close grille ①D  etect Obstacle ③ Set Stop Point
② Horizontal Sensor ④ C
 heck Close grille
Human Detection for Optimized Air
cleaning Photocatalytic Deodorizing filter Phase 4 I Deodorizing Filter
Efficiency kit
LG ThinQ connectivity
Indoor unit senses human presence to switch on or off

300 or more
Phase 3 I Ultra Fine Dust Kit
Dielectric Dust collecting filter
Anytime anywhere access to indoor units with LG ThinQ Ceiling
for maximum power savings of 54%. mobile app. Ceiling Board
Ceiling Board
Dust electrification
Operation On Turning Off Turning On

300 or less
On Off On
Phase 2 I Dust Electrification 500 or

or more
500 or

1,000
more more

4,000 or less
Above 2,500
Pre-filter PM1.0
Dust
Sensor Phase 1 I Pre-filter
Unit : mm

Air
In office Absence In office cleaning
Floor
panel
Learning time for
↑2°C, running
Power saving Max. 54%
25min Power saving
Manageable set time Power saving
(If set time 30min) ①M  onitoring Air status ②M  obile Remote Control
30min/60min/90min Electrical diffusion makes Air condition Easy to check indoor air status Remote control by using mobile phone
dustelectrification. LED Status • Ultra Fine / Extra Fine / Fine Dust • Control Mode / Temperature
Absence → Turn off after 30min (set turn off)
• Day / Week /Month / Yearly / Air flow etc.
Learning time for Absence Cycle Management
5min Dust ③D  isplay Power Consumption
Pre-filter Ultra Fine Dust Kit Deodorizing Filter Check power consumption of A/C
※ Smart Dual Vane Indoor Unit ‘19 Line up. Electrification
※ Data Based on actual test of LG, single product 2 hours measurement result. • Check energy display
Easy removable 6 months /
(cooling 26 ℃, strong wind) pre-filter - Washable
6 months / Dry • Set target energy consumption level

116 / 117
INDOOR UNIT _ CEILING MOUNTED CASSETTE _ SPECIFICATION

DUAL VANE 4WAY CASSETTE DUAL VANE 4WAY CASSETTE


(840 X 840) (840 X 840)
ARNU24GTBB4 / ARNU28GTBB4 ARNU36GTAB4 / ARNU42GTAB4

INDOOR
UNITS
ARNU30GTBB4 ARNU48GTAB4

Available from JUNE 2020 Available from JUNE 2020

CEILING MOUNTED CASSETTE


Model Unit ARNU24GTBB4 ARNU28GTBB4 ARNU30GTBB4 Model Unit ARNU36GTAB4 ARNU42GTAB4 ARNU48GTAB4
Cooling Capacity kW 7.1 8.2 9.0 Cooling Capacity kW 10.6 12.3 14.1
Heating Capacity kW 8.0 9.2 10.0 Heating Capacity kW 11.9 13.8 15.9
Power Input Power Input
Nominal W 32 / 27 / 20 37 / 30 / 22 48 / 36 / 25 Nominal W 69 / 49 / 37 97 / 69 / 49 110 / 76 / 61
(H / M / L) (H / M / L)
Dimensions Body mm 840 x 204 x 840 840 x 204 x 840 840 x 204 x 840 Dimensions Body mm 840 x 288 x 840 840 x 288 x 840 840 x 288 x 840
(W x H x D) Shipping mm 922 x 276 x 917 922 x 276 x 917 922 x 276 x 917 (W x H x D) Shipping mm 922 x 360 X 917 922 x 360 X 917 922 x 360 X 917
Type Full 3D Turbo Fan Full 3D Turbo Fan Full 3D Turbo Fan Type Full 3D Turbo Fan Full 3D Turbo Fan Full 3D Turbo Fan
Motor Output x Number W 51 x 1 51 x 1 51 x 1 Motor Output x Number W 135 x 1 135 x 1 135 x 1
Fan Fan
Air Flow Rate(H/M/L) m3/min 18 / 17 / 15 19 / 17 / 15 21 / 19 / 16 Air Flow Rate(H/M/L) m3/min 29 / 26 / 22 33 / 29 / 26 34 / 30 / 28
Motor Type BLDC BLDC BLDC Motor Type BLDC BLDC BLDC
Air Filter Pre Filter Pre Filter Pre Filter Air Filter Pre Filter Pre Filter Pre Filter
Liquid Side mm(inch) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8) Liquid Side mm(inch) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8)
Pipe Pipe
Gas Side mm(inch) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Gas Side mm(inch) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8)
Connections Connections
Drain Pipe (Internal Dia.) mm(inch) Ø25(1) Ø25(1) Ø25(1) Drain Pipe (Internal Dia.) mm(inch) Ø25(1) Ø25(1) Ø25(1)
Weight Body kg 21 21 21 Weight Body kg 26 26 26
Sound Pressure Level (H / M / L) dB(A) 36 / 34 / 31 39 / 35 / 34 40 / 36 / 33 Sound Pressure Level (H / M / L) dB(A) 42 / 39 / 36 44 / 41 / 39 46 / 43 / 41
Sound Power Level (H / M / L) dB(A) 46 / 44 / 42 50 / 46 / 43 53 / 50 / 45 Sound Power Level (H / M / L) dB(A) 54 / 51 / 47 56 / 53 / 49 58 / 54 / 53
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
Communication Cable mm2 x No. 1.25 x 2C 1.25 x 2C 1.25 x 2C Communication Cable mm2 x No. 1.25 x 2C 1.25 x 2C 1.25 x 2C
PT-AAGW0 PT-AAGW0 PT-AAGW0 PT-AAGW0 PT-AAGW0 PT-AAGW0
Model Name PT-AFGW0 PT-AFGW0 PT-AFGW0 Model Name PT-AFGW0 PT-AFGW0 PT-AFGW0
PT-AEGW0 PT-AEGW0 PT-AEGW0 PT-AEGW0 PT-AEGW0 PT-AEGW0
Decoration Exterior Color White White White Decoration Exterior Color White White White
Panel Panel
RAL Code RAL 9003 RAL 9003 RAL 9003 RAL Code RAL 9003 RAL 9003 RAL 9003
(Accessory) (Accessory)
Net Dimensions Net Dimensions
mm 950 x 35 x 950 950 x 35 x 950 950 x 35 x 950 mm 950 x 35 x 950 950 x 35 x 950 950 x 35 x 950
(W x H x D) (W x H x D)
Net Weight kg 7.1 / 7.5 / 8.5 7.1 / 7.5 / 8.5 7.1 / 7.5 / 8.5 Net Weight kg 7.1 / 7.5 / 8.5 7.1 / 7.5 / 8.5 7.1 / 7.5 / 8.5

Note : 1. Performance tested under EN14511 Note : 1. Performance tested under EN14511
2. Capacities are based on the following conditions 2. Capacities are based on the following conditions
- Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero
3. Due to our policy of innovation, some specifications may be changed without notification 3. Due to our policy of innovation, some specifications may be changed without notification

Accessories Accessories
Chassis ARNU24GTBB4 ARNU28GTBB4 ARNU30GTBB4 Chassis ARNU36GTAB4 ARNU42GTAB4 ARNU48GTAB4
Drain Pump ○ Drain Pump ○
Cassette Cover PTDCA Cassette Cover PTDCA
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
EEV Kit - EEV Kit -
Independent Power Module PRIP0 Independent Power Module PRIP0
Robot Cleaner - Robot Cleaner -
Pre Filter (washable) ○ Pre Filter (washable) ○
Ion Generator - Ion Generator -
CO2 Sensor - CO2 Sensor -
Ventilation Kit - Ventilation Kit -
IR Receiver - IR Receiver -
Zone Controller - Zone Controller -
PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible), PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible),
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus) PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus)
External Input (1 Point) ○ External Input (1 Point) ○
Wi-Fi PWFMDD200 Wi-Fi PWFMDD200
Human detection sensor PTVSAA0 Human detection sensor PTVSAA0
Floor Temperature Sensor PT-AFGW0 :○ Floor Temperature Sensor PT-AFGW0 :○
Air cleaning kit PT-AFGW0 : PTAFMP0 Air cleaning kit PT-AFGW0 : PTAFMP0
Elevation Grille PT-AEGW0 :○ Elevation Grille PT-AEGW0 :○

1) Available from April 2020 1) Available from April 2020

118 / 119
INDOOR UNIT _ CEILING MOUNTED CASSETTE _ SPECIFICATION

DUAL VANE 4WAY CASSETTE DUAL VANE 4WAY CASSETTE


(840 X 840) HIGH SENSIBLE (840 X 840) HIGH SENSIBLE
ARNU07GTAA4 / ARNU09GTAA4 ARNU24GTAA4 / ARNU28GTAA4

INDOOR
UNITS
ARNU12GTAA4 / ARNU15GTAA4 ARNU36GTAA4 / ARNU42GTAA4
ARNU18GTAA4 ARNU48GTAA4

Available from JUNE 2020 Available from JUNE 2020

CEILING MOUNTED CASSETTE


Model Unit ARNU07GTAA4 ARNU09GTAA4 ARNU12GTAA4 ARNU15GTAA4 ARNU18GTAA4 Model Unit ARNU24GTAA4 ARNU28GTAA4 ARNU36GTAA4 ARNU42GTAA4 ARNU48GTAA4
Cooling Capacity kW 2.2 2.8 3.6 4.5 5.6 Cooling Capacity kW 7.1 8.2 10.6 12.3 14.1
Heating Capacity kW 2.5 3.2 4.0 5.0 6.3 Heating Capacity kW 8.0 9.2 11.9 13.8 15.9
Power Input Power Input
Nominal W 23 / 16 / 11 25 / 18 / 11 26 / 19 / 13 29 / 20 / 15 31 / 23 / 16 Nominal W 35 / 29 / 20 40 / 31 / 25 65 / 43 / 31 86 / 65 / 43 100 / 67 / 53
(H / M / L) (H / M / L)
Dimensions Body mm 840 x 288 x 840 840 x 288 x 840 840 x 288 x 840 840 x 288 x 840 840 x 288 x 840 Dimensions Body mm 840 x 288 x 840 840 x 288 x 840 840 x 288 x 840 840 x 288 x 840 840 x 288 x 840
(W x H x D) Shipping mm 922 x 360 X 917 922 x 360 X 917 922 x 360 X 917 922 x 360 X 917 922 x 360 X 917 (W x H x D) Shipping mm 922 x 360 X 917 922 x 360 X 917 922 x 360 X 917 922 x 360 X 917 922 x 360 X 917
Type Full 3D Turbo Fan Full 3D Turbo Fan Full 3D Turbo Fan Full 3D Turbo Fan Full 3D Turbo Fan Type Full 3D Turbo Fan Full 3D Turbo Fan Full 3D Turbo Fan Full 3D Turbo Fan Full 3D Turbo Fan
Motor Output x Number W 166 x 1 166 x 1 166 x 1 166 x 1 166 x 1 Motor Output x Number W 166 x 1 166 x 1 166 x 1 166 x 1 166 x 1
Fan Running Cuurent A 0.23 0.25 0.25 0.27 0.28 Fan Running Cuurent A 0.38 0.46 0.60 0.80 0.88
Air Flow Rate(H/M/L) m3/min 19 / 16 / 13 19 / 16 / 13 20 / 17 / 15 20 / 17 / 15 21 / 19 / 16 Air Flow Rate(H/M/L) m3/min 23 / 21 / 19 24 / 22 / 20 28 / 24 / 21 31 / 28 / 24 33 / 28 / 26
Motor Type BLDC BLDC BLDC BLDC BLDC Motor Type BLDC BLDC BLDC BLDC BLDC
Air Filter Pre Filter Pre Filter Pre Filter Pre Filter Pre Filter Air Filter Pre Filter Pre Filter Pre Filter Pre Filter Pre Filter
Liquid Side mm(inch) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8) Liquid Side mm(inch) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8)
Pipe Pipe
Gas Side mm(inch) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Gas Side mm(inch) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8)
Connections Connections
Drain Pipe (Internal Dia.) mm(inch) Ø25(1) Ø25(1) Ø25(1) Ø25(1) Ø25(1) Drain Pipe (Internal Dia.) mm(inch) Ø25(1) Ø25(1) Ø25(1) Ø25(1) Ø25(1)
Weight Body kg 26 26 26 26 26 Weight Body kg 26 26 26 26 26
Sound Pressure Level (H / M / L) dB(A) 32 / 30 / 26 33 / 30 / 26 34 / 31 / 27 34 / 32 / 29 35 / 32 / 30 Sound Pressure Level (H / M / L) dB(A) 39 / 36 / 33 40 / 37 / 34 42 / 39 / 35 46 / 42 / 39 47 / 43 / 41
Sound Power Level (H / M / L) dB(A) 41 / 38 / 34 42 / 39 / 34 42 / 40 / 36 43 / 40 / 37 44 / 41 / 38 Sound Power Level (H / M / L) dB(A) 47 / 45 / 42 48 / 46 / 42 51 / 48 / 44 54 / 51 / 48 56 / 52 / 50
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
Communication Cable mm2 x No. 1.25 x 2C 1.25 x 2C 1.25 x 2C 1.25 x 2C 1.25 x 2C Communication Cable mm2 x No. 1.25 x 2C 1.25 x 2C 1.25 x 2C 1.25 x 2C 1.25 x 2C
Exterior Color White White White White White PT-AAGW0 PT-AAGW0 PT-AAGW0 PT-AAGW0 PT-AAGW0
Model Name PT-AFGW0 PT-AFGW0 PT-AFGW0 PT-AFGW0 PT-AFGW0
Decoration RAL Code RAL 9003 RAL 9003 RAL 9003 RAL 9003 RAL 9003 PT-AEGW0 PT-AEGW0 PT-AEGW0 PT-AEGW0 PT-AEGW0
Panel Net Dimensions
(Accessory) mm 950 x 35 x 950 950 x 35 x 950 950 x 35 x 950 950 x 35 x 950 950 x 35 x 950 Decoration Exterior Color White White White White White
(W x H x D) Panel
Net Weight kg 7.1 / 7.5 / 8.5 7.1 / 7.5 / 8.5 7.1 / 7.5 / 8.5 7.1 / 7.5 / 8.5 7.1 / 7.5 / 8.5 RAL Code RAL 9003 RAL 9003 RAL 9003 RAL 9003 RAL 9003
(Accessory)
Net Dimensions
mm 950 x 35 x 950 950 x 35 x 950 950 x 35 x 950 950 x 35 x 950 950 x 35 x 950
Note : 1. Performance tested under EN14511 (W x H x D)
2. Capacities are based on the following conditions Net Weight kg 7.1 / 7.5 / 8.5 7.1 / 7.5 / 8.5 7.1 / 7.5 / 8.5 7.1 / 7.5 / 8.5 7.1 / 7.5 / 8.5
- Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero Note : 1. Performance tested under EN14511
3. Due to our policy of innovation, some specifications may be changed without notification 2. Capacities are based on the following conditions
- Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero
3. Due to our policy of innovation, some specifications may be changed without notification

Accessories Accessories
Chassis ARNU07GTAA4 ARNU09GTAA4 ARNU12GTAA4 ARNU15GTAA4 ARNU18GTAA4 Chassis ARNU24GTAA4 ARNU28GTAA4 ARNU36GTAA4 ARNU42GTAA4 ARNU48GTAA4
Drain Pump ○ Drain Pump ○
Cassette Cover PTDCA Cassette Cover PTDCA
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
EEV Kit - EEV Kit -
Independent Power Module PRIP0 Independent Power Module PRIP0
Robot Cleaner - Robot Cleaner -
Pre Filter (washable) ○ Pre Filter (washable) ○
Ion Generator - Ion Generator -
CO2 Sensor - CO2 Sensor -
Ventilation Kit - Ventilation Kit -
IR Receiver - IR Receiver -
Zone Controller - Zone Controller -
PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible), PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible),
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus) PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus)
External Input (1 Point) ○ External Input (1 Point) ○
Wi-Fi PWFMDD200 Wi-Fi PWFMDD200
Human detection sensor PTVSAA0 Human detection sensor PTVSAA0
Floor Temperature Sensor PT-AFGW0 :○ Floor Temperature Sensor PT-AFGW0 :○
Air cleaning kit PT-AFGW0 : PTAFMP0 Air cleaning kit PT-AFGW0 : PTAFMP0
Elevation Grille PT-AEGW0 :○ Elevation Grille PT-AEGW0 :○

1) Available from April 2020 1) Available from April 2020

120 / 121
INDOOR UNIT _ CEILING MOUNTED CASSETTE _ SPECIFICATION

4 WAY CASSETTE (570 X 570) 4 WAY CASSETTE (570 X 570)


ARNU05GTRB4 / ARNU07GTRB4 ARNU15GTQB4 / ARNU18GTQB4
ARNU09GTRB4 / ARNU12GTRB4 ARNU21GTQB4

INDOOR
UNITS
Model Unit ARNU05GTRB4 ARNU07GTRB4 ARNU09GTRB4 ARNU12GTRB4 Model Unit ARNU15GTQB4 ARNU18GTQB4 ARNU21GTQB4
Cooling Capacity kW 1.6 2.2 2.8 3.6 Cooling Capacity kW 4.5 5.6 6.0
Heating Capacity kW 1.8 2.5 3.2 4.0 Heating Capacity kW 5.0 6.3 6.8
Power Input Power Input
Nominal W 13 / 12 / 11 13 / 12 / 11 14 / 13 / 12 17 / 15 / 13 Nominal W 24 / 21 / 18 25 / 22 / 19 28 / 23 / 20
(H / M / L) (H / M / L)
Dimensions Body mm 570 x 214 x 570 570 x 214 x 570 570 x 214 x 570 570 x 214 x 570 Dimensions Body mm 570 x 256 x 570 570 x 256 x 570 570 x 256 x 570
(W x H x D) Shipping mm 667 x 285 x 646 667 x 285 x 646 667 x 285 x 646 667 x 285 x 646 (W x H x D) Shipping mm 667 x 327 x 646 667 x 327 x 646 667 x 327 x 646
Type Turbo Fan Turbo Fan Turbo Fan Turbo Fan Type Turbo Fan Turbo Fan Turbo Fan
Motor Output x Number W 43 x 1 43 x 1 43 x 1 43 x 1 Motor Output x Number W 43 x 1 43 x 1 43 x 1
Fan Fan
Air Flow Rate (H / M / L) m³/min 7.5 / 7.0 / 6.6 7.5 / 7.0 / 6.6 8.0 / 7.5 / 7.1 8.7 / 8.0 / 7.0 Air Flow Rate (H / M / L) m³/min 11.0 / 10.0 / 9.3 11.2 / 11.0 / 10.0 12.0 / 11.1 / 9.4
Motor Type BLDC BLDC BLDC BLDC Motor Type BLDC BLDC BLDC
Air Filter Pre Filter Pre Filter Pre Filter Pre Filter Air Filter Pre Filter Pre Filter Pre Filter
Liquid Side mm (inch) Ø6.35 (1/4) Ø6.35 (1/4) Ø6.35 (1/4) Ø6.35 (1/4) Liquid Side mm (inch) Ø6.35 (1/4) Ø6.35 (1/4) Ø9.52 (3/8)
Pipe Pipe
Gas Side mm (inch) Ø12.7 (1/2) Ø12.7 (1/2) Ø12.7 (1/2) Ø12.7 (1/2) Gas Side mm (inch) Ø12.7 (1/2) Ø12.7 (1/2) Ø15.88 (5/8)
Connections Connections
Drain Pipe (Internal Dia.) mm (inch) Ø25 (1) Ø25 (1) Ø25 (1) Ø25 (1) Drain Pipe (Internal Dia.) mm (inch) Ø25 (1) Ø25 (1) Ø25 (1)
Weight Body kg 12.6 12.6 13.7 13.7 Weight Body kg 15.0 15.0 15.0
Sound Pressure Levels (H / M / L) dB(A) 29 / 27 / 26 29 / 27 / 26 30 / 29 / 27 32 / 30 / 27 Sound Pressure Levels (H / M / L) dB(A) 36 / 34 / 32 37 / 35 / 34 40 / 38 / 34
Sound Power Levels (H / M / L) dB(A) 45 / 43 / 42 45 / 43 / 42 46 / 43 / 42 48 / 46 / 43 Sound Power Levels (H / M / L) dB(A) 50 / 48 / 46 51 / 50 / 46 53 / 51 / 46
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
PT-UQC PT-UQC PT-UQC PT-UQC PT-UQC PT-UQC PT-UQC
Model Name Model Name
PT-QCHW0 PT-QCHW0 PT-QCHW0 PT-QCHW0 PT-QCHW0 PT-QCHW0 PT-QCHW0
Decoration Exterior Color Morning Fog Morning Fog Morning Fog Morning Fog Decoration Exterior Color Morning Fog Morning Fog Morning Fog
Panel RAL Code RAL 9001 RAL 9001 RAL 9001 RAL 9001 Panel RAL Code RAL 9001 RAL 9001 RAL 9001
(Accessory) Net Dimensions 700 x 22 x700 620 x 20 700 x 22 x700 620 x 20 700 x 22 x700 620 x 20 700 x 22 x700 620 x 20 (Accessory) Net Dimensions
mm mm 700 x 22 x700 620 x 20 x 620 700 x 22 x700 620 x 20 x 620 700 x 22 x700 620 x 20 x 620
(W x H x D) x 620 x 620 x 620 x 620 (W x H x D)
Net Weight kg 3.0 / 3.0 3.0 / 3.0 3.0 / 3.0 3.0 / 3.0 Net Weight kg 3.0 / 3.0 3.0 / 3.0 3.0 / 3.0

Note : 1. Performance tested under EN14511 Note : 1. Performance tested under EN14511
2. Capacities are based on the following conditions 2. Capacities are based on the following conditions
- Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero
3. Due to our policy of innovation, some specifications may be changed without notification 3. Due to our policy of innovation, some specifications may be changed without notification

Accessories Accessories
Chassis ARNU05GTRB4 ARNU07GTRB4 ARNU09GTRB4 ARNU12GTRB4 Chassis ARNU15GTQB4 ARNU18GTQB4 ARNU21GTQB4
Drain Pump ○ Drain Pump ○
Cassette Cover PTDCQ Cassette Cover PTDCQ
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
EEV Kit PRGK024A0 (~4.5kW) EEV Kit PRGK024A0 (~4.5kW)
Independent Power Module PRIP0 Independent Power Module PRIP0
Robot Cleaner - Robot Cleaner -
Pre Filter (washable) ○ Pre Filter (washable) ○
Ion Generator - Ion Generator -
CO2 Sensor - CO2 Sensor -
Ventilation Kit PTVK430 Ventilation Kit PTVK430
IR Receiver - IR Receiver -
Zone Controller - Zone Controller -
PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible), PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible),
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus) PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus)
External Input (1 point) ○ External Input (1 point) ○
Wi-Fi PWFMDD200 Wi-Fi PWFMDD200

※ ○ : Applied, - : Not applied ※ ○ : Applied, - : Not applied


Option : Refer to model name in table Option : Refer to model name in table
1) Available from April 2020 1) Available from April 2020

122 / 123
INDOOR UNIT _ CEILING MOUNTED CASSETTE _ SPECIFICATION

4 WAY CASSETTE (840 X 840) 4 WAY CASSETTE (840 X 840)


ARNU24GTPC4 / ARNU28GTPC4 ARNU42GTM / C4ARNU48GTMC4
ARNU30GTPC4 / ARNU36GTNC4 ARNU54GTMC4

INDOOR
UNITS
Model Unit ARNU24GTPC4 ARNU28GTPC4 ARNU30GTPC4 ARNU36GTNC4 Model Unit ARNU42GTMC4 ARNU48GTMC4 ARNU54GTMC4
Cooling Capacity kW 7.1 8.2 9.0 10.6 Cooling Capacity kW 12.3 14.1 15.8
Heating Capacity kW 8.0 9.2 10.0 11.9 Heating Capacity kW 13.8 15.9 18
Power Input Power Input
Nominal W 31 / 26 / 23 40 / 31 / 25 40 / 34 / 27 70 / 53 / 43 Nominal W 104 / 75 / 53 120 / 80 / 62 135 / 93 / 70
(H / M / L) (H / M / L)
Dimensions Body mm 840 x 204 x 840 840 x 204 x 840 840 x 204 x 840 840 x 246 x 840 Dimensions Body mm 840 x 288 x 840 840 x 288 x 840 840 x 288 x 840
(W x H x D) Shipping mm 922 x 276 x 917 922 x 276 x 917 922 x 276 x 917 922 x 318 x 917 (W x H x D) Shipping mm 922 x 360 x 917 922 x 360 x 917 922 x 360 x 917
Type Turbo Fan Turbo Fan Turbo Fan Turbo Fan Type Turbo Fan Turbo Fan Turbo Fan
Motor Output x Number W 30 x 1 30 x 1 30 x 1 135 x 1 Motor Output x Number W 135 x 1 135 x 1 135 x 1
Fan Fan
Air Flow Rate (H / M / L) m³/min 17.0 / 15.0 / 13.0 19.0 / 16.0 / 14.0 24.3 / 22.8 / 19.5 25.0 / 21.0 / 19.0 Air Flow Rate (H / M / L) m³/min 30.0 / 27.0 / 24.0 31.0 / 29.0 / 27.0 34.0 / 32.0 / 27.0
Motor Type BLDC BLDC BLDC BLDC Motor Type BLDC BLDC BLDC
Air Filter Pre Filter Pre Filter Pre Filter Pre Filter Air Filter Pre Filter Pre Filter Pre Filter
Liquid Side mm (inch) Ø9.52 (3/8) Ø9.52 (3/8) Ø9.52 (3/8) Ø9.52 (3/8) Liquid Side mm (inch) Ø9.52 (3/8) Ø9.52 (3/8) Ø9.52 (3/8)
Pipe Pipe
Gas Side mm (inch) Ø15.88 (5/8) Ø15.88 (5/8) Ø15.88 (5/8) Ø15.88 (5/8) Gas Side mm (inch) Ø15.88 (5/8) Ø15.88 (5/8) Ø15.88 (5/8)
Connections Connections
Drain Pipe (Internal Dia.) mm (inch) Ø25 (1) Ø25 (1) Ø25 (1) Ø25 (1) Drain Pipe (Internal Dia.) mm (inch) Ø25 (1) Ø25 (1) Ø25 (1)
Weight Body kg 20.8 20.8 20.8 23.5 Weight Body kg 25.6 25.6 26.5
Sound Pressure Levels (H / M / L) dB(A) 36 / 34 / 31 39 / 35 / 33 40 / 36 / 33 43 / 40 / 37 Sound Pressure Levels (H / M / L) dB(A) 44 / 41 / 38 46 / 43 / 41 50 / 48 / 44
Sound Power Levels (H / M / L) dB(A) 46 / 44 / 43 52 / 46 / 44 58 / 57 / 54 56 / 53 / 51 Sound Power Levels (H / M / L) dB(A) 58 / 55 / 50 60 / 56 / 55 60 / 58 / 55
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
PT-UMC1 PT-UMC1 PT-UMC1 PT-UMC1 PT-UMC1 PT-UMC1 PT-UMC1
Model Name Model Name
PT-MCHW0 PT-MCHW0 PT-MCHW0 PT-MCHW0 PT-MCHW0 PT-MCHW0 PT-MCHW0
Decoration Exterior Color Morning Fog Morning Fog Morning Fog Morning Fog Decoration Exterior Color Morning Fog Morning Fog Morning Fog
Panel RAL Code RAL 9001 RAL 9001 RAL 9001 RAL 9001 Panel RAL Code RAL 9001 RAL 9001 RAL 9001
(Accessory) Net Dimensions 950 x 25 x 950 950 x 25 x 950 950 x 25 x 950 950 x 25 x 950 (Accessory) Net Dimensions 950 x 25 x 950 950 x 25 x 950 950 x 25 x 950
mm mm
(W x H x D) 950 x 35 x 950 950 x 35 x 950 950 x 35 x 950 950 x 35 x 950 (W x H x D) 950 x 35 x 950 950 x 35 x 950 950 x 35 x 950
Net Weight kg 5.0 / 6.3 5.0 / 6.3 5.0 / 6.3 5.0 / 6.3 Net Weight kg 5.0 / 6.3 5.0 / 6.3 5.0 / 6.3

Note : 1. Performance tested under EN14511 Note : 1. Performance tested under EN14511
2. Capacities are based on the following conditions 2. Capacities are based on the following conditions
- Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero
3. Due to our policy of innovation, some specifications may be changed without notification 3. Due to our policy of innovation, some specifications may be changed without notification

Accessories Accessories
Chassis ARNU24GTPC4 ARNU28GTPC4 ARNU30GTPC4 ARNU36GTNC4 Chassis ARNU42GTMC4 ARNU48GTMC4 ARNU54GTMC4
Drain Pump ○ Drain Pump ○
Cassette Cover PTDCM Cassette Cover PTDCM
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
EEV Kit - EEV Kit -
Independent Power Module PRIP0 Independent Power Module PRIP0
Robot Cleaner - Robot Cleaner -
Pre Filter (washable) ○ Pre Filter (washable) ○
Ion Generator - Ion Generator -
CO2 Sensor - CO2 Sensor -
Ventilation Kit PTVK430 Ventilation Kit PTVK430
IR Receiver - IR Receiver -
Zone Controller - Zone Controller -
PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible), PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible),
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB502 (Modbus) PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB502 (Modbus)
External Input (1 point) ○ External Input (1 point) ○
Wi-Fi PWFMDD200 Wi-Fi PWFMDD200

※ ○ : Applied, - : Not applied ※ ○ : Applied, - : Not applied


Option : Refer to model name in table Option : Refer to model name in table
1) Available from April 2020 1) Available from April 2020

124 / 125
INDOOR UNIT _ CEILING MOUNTED CASSETTE _ SPECIFICATION

4 WAY CASSETTE (840 X 840) 4 WAY CASSETTE (840 X 840)


ARNU07GTNA4 / ARNU09GTNA4 ARNU24GTMA4 / ARNU28GTMA4
ARNU12GTNA4 / ARNU15GTNA4 ARNU36GTMA4 / ARNU42GTMA4
ARNU18GTNA4

INDOOR
UNITS
Model Unit ARNU07GTNA4 ARNU09GTNA4 ARNU12GTNA4 ARNU15GTNA4 ARNU18GTNA4 Model Unit ARNU24GTMA4 ARNU28GTMA4 ARNU36GTMA4 ARNU42GTMA4
Cooling Capacity kW 2.2 2.8 3.6 4.5 5.6 Cooling Capacity kW 7.1 8.2 10.6 12.3
Heating Capacity kW 2.5 3.2 4 5 6.3 Heating Capacity kW 8 9.2 11.9 13.8
Power Input Power Input
Nominal W 18 / 15 / 12 19 / 15 / 12 22 / 17 / 14 25 / 17 / 14 27 / 18 / 14 Nominal W 47 / 39 / 31 52 / 43 / 31  64 / 47 / 34 104 / 75 / 53
(H / M / L) (H / M / L)
Dimensions Body mm 840 x 246 x 840 840 x 246 x 840 840 x 246 x 840 840 x 246 x 840 840 x 246 x 840 Dimensions Body mm 840 x 288 x 840 840 x 288 x 840 840 x 288 x 840 840 x 288 x 840
(W x H x D) Shipping mm 922 x 318 x 917 922 x 318 x 917 922 x 318 x 917 922 x 318 x 917 922 x 318 x 917 (W x H x D) Shipping mm 922 x 360 x 917 922 x 360 x 917 922 x 360 x 917 922 x 360 x 917
Type Turbo Fan Turbo Fan Turbo Fan Turbo Fan Turbo Fan Type Turbo Fan Turbo Fan Turbo Fan Turbo Fan
Motor Output x Number W 135 x 1 135 x 1 135 x 1 135 x 1 135 x 1 Motor Output x Number W 135 x 1 135 x 1 135 x 1 135 x 1
Fan Fan
Air Flow Rate (H / M / L) m³/min 13.0 / 12.0 / 11.0 13.5 / 12.0 / 11.0 14.0 / 13.0 / 12.0 15.0 / 13.0 / 12.0 16.0 / 14.0 / 12.0 Air Flow Rate (H / M / L) m³/min 22.0 / 20.0 / 18.0 23.0 / 21.0 / 18.0 26.0 / 23.0 / 20.0 30.0 / 26.0 / 23.0
Motor Type BLDC BLDC BLDC BLDC BLDC Motor Type BLDC BLDC BLDC BLDC
Air Filter Pre Filter Pre Filter Pre Filter Pre Filter Pre Filter Air Filter Pre Filter Pre Filter Pre Filter Pre Filter
Liquid Side mm (inch) Ø9.52 (3/8) Ø9.52 (3/8) Ø9.52 (3/8) Ø9.52 (3/8) Ø9.52 (3/8) Liquid Side mm (inch) Ø9.52 (3/8) Ø9.52 (3/8) Ø9.52 (3/8) Ø9.52 (3/8)
Pipe Pipe
Gas Side mm (inch) Ø15.88 (5/8) Ø15.88 (5/8) Ø15.88 (5/8) Ø15.88 (5/8) Ø15.88 (5/8) Gas Side mm (inch) Ø15.88 (5/8) Ø15.88 (5/8) Ø15.88 (5/8) Ø15.88 (5/8)
Connections Connections
Drain Pipe (Internal Dia.) mm (inch) Ø25 (1) Ø25 (1) Ø25 (1) Ø25 (1) Ø25 (1) Drain Pipe (Internal Dia.) mm (inch) Ø25 (1) Ø25 (1) Ø25 (1) Ø25 (1)
Weight Body kg 23.5 23.5 23.5 23.5 23.5 Weight Body kg 25.6 25.6 25.6 25.6
Sound Pressure Levels (H / M / L) dB(A) 35 / 33 / 30 35 / 33 / 30 37 / 35 / 33 39 / 35 / 33 40 / 35 / 33 Sound Pressure Levels (H / M / L) dB(A) 42 / 40 / 38 43 / 41 / 38 46 / 42 / 39 49 / 45 / 42
Sound Power Levels (H / M / L) dB(A) 42 / 38 / 36 42 / 38 / 36 43 / 40 / 38 44 / 40 / 38 45 / 41 / 38 Sound Power Levels (H / M / L) dB(A) 48 / 45 / 43 49 / 47 / 43 52 / 48 / 44 55 / 51 / 48
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 Power Supply Ø, V, Hz 1, 220 ~ 240, 50 1, 220 ~ 240, 50 1, 220 ~ 240, 50 1, 220 ~ 240, 50
Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
PT-UMC1 PT-UMC1 PT-UMC1 PT-UMC1 PT-UMC1 PT-UMC1 PT-UMC1 PT-UMC1 PT-UMC1
Model Name Model Name
PT-MCHW0 PT-MCHW0 PT-MCHW0 PT-MCHW0 PT-MCHW0 PT-MCHW0 PT-MCHW0 PT-MCHW0 PT-MCHW0
Decoration Exterior Color Morning Fog Morning Fog Morning Fog Morning Fog Morning Fog Decoration Exterior Color Morning Fog Morning Fog Morning Fog Morning Fog
Panel RAL Code RAL 9001 RAL 9001 RAL 9001 RAL 9001 RAL 9001 Panel RAL Code RAL 9001 RAL 9001 RAL 9001 RAL 9001
(Accessory) Net Dimensions 950 x 25 x 950 950 x 25 x 950 950 x 25 x 950 950 x 25 x 950 950 x 25 x 950 (Accessory) Net Dimensions 950 x 25 x 950 950 x 25 x 950 950 x 25 x 950 950 x 25 x 950
mm mm
(W x H x D) 950 x 35 x 950 950 x 35 x 950 950 x 35 x 950 950 x 35 x 950 950 x 35 x 950 (W x H x D) 950 x 35 x 950 950 x 35 x 950 950 x 35 x 950 950 x 35 x 950
Net Weight kg 5.0 / 6.3 5.0 / 6.3 5.0 / 6.3 5.0 / 6.3 5.0 / 6.3 Net Weight kg 5.0 / 6.3 5.0 / 6.3 5.0 / 6.3 5.0 / 6.3

Note : 1. Performance tested under EN14511 Note : 1. Performance tested under EN14511
2. Capacities are based on the following conditions 2. Capacities are based on the following conditions
- Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero
3. Due to our policy of innovation, some specifications may be changed without notification 3. Due to our policy of innovation, some specifications may be changed without notification

Accessories Accessories
Chassis ARNU07GTNA4 ARNU09GTNA4 ARNU12GTNA4 ARNU15GTNA4 ARNU18GTNA4 Chassis ARNU24GTMA4 ARNU28GTMA4 ARNU36GTMA4 ARNU42GTMA4
Drain Pump ○ Drain Pump ○
Cassette Cover PTDCM Cassette Cover PTDCM
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
EEV Kit - EEV Kit -
Independent Power Module PRIP0 Independent Power Module PRIP0
Robot Cleaner - Robot Cleaner -
Pre Filter (washable) ○ Pre Filter (washable) ○
Ion Generator - Ion Generator -
CO2 Sensor - CO2 Sensor -
Ventilation Kit PTVK430 Ventilation Kit PTVK430
IR Receiver - IR Receiver -
Zone Controller - Zone Controller -
PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible), PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible),
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus) PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus)
External Input (1 point) ○ External Input (1 point) ○
Wi-Fi PWFMDD200 Wi-Fi PWFMDD200

※ ○ : Applied, - : Not applied ※ ○ : Applied, - : Not applied


Option : Refer to model name in table Option : Refer to model name in table
1) Available from April 2020 1) Available from April 2020

126 / 127
INDOOR UNIT _ CEILING MOUNTED CASSETTE _ SPECIFICATION

2 WAY CASSETTE 2 WAY CASSETTE


ARNU09GTSC4 / ARNU12GTSC4 ARNU18GTSC4 / ARNU24GTSC4

INDOOR
UNITS
CEILING MOUNTED CASSETTE
Model Unit ARNU09GTSC4 ARNU12GTSC4 Model Unit ARNU18GTSC4 ARNU24GTSC4
Cooling Capacity kW 2.8 3.6 Cooling Capacity kW 5.6 7.1
Heating Capacity kW 3.2 4.0 Heating Capacity kW 6.3 8.0
Power Input Power Input
Nominal W 16 / 14 / 11 18 / 14 / 11 Nominal W 19 / 16 / 14 31 / 22 / 14
(H / M / L) (H / M / L)
Dimensions Body mm 830 x 225 x 600 830 x 225 x 600 Dimensions Body mm 830 x 225 x 600 830 x 225 x 600
(W x H x D) Shipping mm 1,055 × 290 × 682 1,055 × 290 × 682 (W x H x D) Shipping mm 1,055 × 290 × 682 1,055 × 290 × 682
Type Turbo Fan Turbo Fan Type Turbo Fan Turbo Fan
Motor Output x Number W x No. 37 x 1 37 x 1 Motor Output x Number W x No. 37 x 1 37 x 1
Fan Fan
Air Flow Rate (H / M / L) m³/min 10.8 / 9.8 / 9.1 11.1 / 10.3 / 9.1 Air Flow Rate (H / M / L) m³/min 11.8 / 10.8 / 9.8 14.5 / 12.4 / 10.3
Motor Type BLDC BLDC Motor Type BLDC BLDC
Air Filter Pre Filter Pre Filter Air Filter Pre Filter Pre Filter
Liquid Side mm (inch) Ø6.35 (1/4) Ø6.35 (1/4) Liquid Side mm (inch) Ø6.35 (1/4) Ø9.52 (3/8)
Pipe Pipe
Gas Side mm (inch) Ø12.7 (1/2) Ø12.7 (1/2) Gas Side mm (inch) Ø12.7 (1/2) Ø15.88 (5/8)
Connections Connections
Drain Pipe (Internal Dia.) mm (inch) Ø25 (1) Ø25 (1) Drain Pipe (Internal Dia.) mm (inch) Ø25 (1) Ø25 (1)
Weight Body kg 18.1 18.1 Weight Body kg 18.1 18.1
Sound Pressure Levels (H / M / L) dB(A) 33 / 31 / 29 34 / 32 / 29 Sound Pressure Levels (H / M / L) dB(A) 35 / 33 / 31 40 / 37 / 33
Sound Power Levels (H / M / L) dB(A) 42 / 40 / 38 43 / 41 / 39 Sound Power Levels (H / M / L) dB(A) 44 / 42 / 40 48 / 45 / 40
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50
Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
Model Name PT-USC PT-USC Model Name PT-USC PT-USC
Exterior Color Morning Fog Morning Fog Exterior Color Morning Fog Morning Fog
Decoration Decoration
Panel RAL Code RAL 9001 RAL 9001 Panel RAL Code RAL 9001 RAL 9001
(Accessory) Net Dimensions mm 1,100 x 28 x 690 1,100 x 28 x 690 (Accessory) Net Dimensions mm 1,100 x 28 x 690 1,100 x 28 x 690
(W x H x D) (W x H x D)
Net Weight kg 4.7 4.7 Net Weight kg 4.7 4.7

Note : 1. Performance tested under EN14511 Note : 1. Performance tested under EN14511
2. Capacities are based on the following conditions 2. Capacities are based on the following conditions
- Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero
3. Due to our policy of innovation, some specifications may be changed without notification 3. Due to our policy of innovation, some specifications may be changed without notification

Accessories Accessories
Chassis ARNU09GTSC4 ARNU12GTSC4 Chassis ARNU18GTSC4 ARNU24GTSC4
Drain Pump ○ Drain Pump ○
Cassette Cover - Cassette Cover -
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
EEV Kit PRGK024A0 (~5.6kW) EEV Kit PRGK024A0 (~5.6kW)
Independent Power Module PRIP0 Independent Power Module PRIP0
Robot Cleaner - Robot Cleaner -
Pre Filter (washable) ○ Pre Filter (washable) ○
Ion Generator - Ion Generator -
CO2 Sensor - CO2 Sensor -
Ventilation Kit - Ventilation Kit -
IR Receiver - IR Receiver -
Zone Controller - Zone Controller -
PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible), PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible),
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB320 (Universal input ), PDRYCB400 (2 points input), PDRYCB500 (Modbus)
1)
PDRYCB320 (Universal input ), PDRYCB400 (2 points input), PDRYCB500 (Modbus)
1)

External Input (1 point) ○ External Input (1 point) ○


Wi-Fi PWFMDD200 Wi-Fi PWFMDD200

※ ○ : Applied, - : Not applied ※ ○ : Applied, - : Not applied


Option : Refer to model name in table Option : Refer to model name in table
1) Available from April 2020 1) Available from April 2020

128 / 129
INDOOR UNIT _ CEILING MOUNTED CASSETTE _ SPECIFICATION

1 WAY CASSETTE 1 WAY CASSETTE


ARNU07GTUB4 / ARNU09GTUB4 ARNU18GTTB4 / ARNU24GTTB4
ARNU12GTUB4

INDOOR
UNITS
CEILING MOUNTED CASSETTE
Model Unit ARNU07GTUB4 ARNU09GTUB4 ARNU12GTUB4 Model Unit ARNU18GTTB4 ARNU24GTTB4
Cooling Capacity kW 2.2 2.8 3.6 Cooling Capacity kW 5.6 7.1
Heating Capacity kW 2.5 3.2 4.0 Heating Capacity kW 6.3 7.1
Power Input Power Input
Nominal W 20 / 18 / 16 22 / 20 / 18 24 / 22 / 20 Nominal W 38 / 28 / 24 51 / 33 / 26
(H / M / L) (H / M / L)
Dimensions Body mm 860 x 132 x 450 860 x 132 x 450 860 x 132 x 450 Dimensions Body mm 1,180 x 132 x 450 1,180 x 132 x 450
(W x H x D) Shipping mm 1,129 x 259 x 538 1,129 x 259 x 538 1,129 x 259 x 538 (W x H x D) Shipping mm 1,499 x 259 x 538 1,499 x 259 x 538
Type Cross Flow Fan Cross Flow Fan Cross Flow Fan Type Cross Flow Fan Cross Flow Fan
Motor Output x Number W x No. 30 x 1 30 x 1 30 x 1 Motor Output x Number W x No. 30 x 1 30 x 1
Fan Fan
Air Flow Rate (H / M / L) m³/min 8.2 / 7.3 / 6.4 9.2 / 8.6 / 8.2 10.0 / 9.2 / 8.2 Air Flow Rate (H / M / L) m³/min 13.3 / 12.1 / 10.9 14.6 / 13.3 / 11.5
Motor Type BLDC BLDC BLDC Motor Type BLDC BLDC
Air Filter Pre Filter Pre Filter Pre Filter Air Filter Pre Filter Pre Filter
Liquid Side mm (inch) Ø6.35 (1/4) Ø6.35 (1/4) Ø6.35 (1/4) Liquid Side mm (inch) Ø6.35 (1/4) Ø9.52 (3/8)
Pipe Pipe
Gas Side mm (inch) Ø12.7 (1/2) Ø12.7 (1/2) Ø12.7 (1/2) Gas Side mm (inch) Ø12.7 (1/2) Ø15.88 (5/8)
Connections Connections
Drain Pipe (Internal Dia.) mm (inch) Ø25 (1) Ø25 (1) Ø25 (1) Drain Pipe (Internal Dia.) mm (inch) Ø25 (1) Ø25 (1)
Weight Body kg 13.6 13.6 13.6 Weight Body kg 15.6 15.6
Sound Pressure Levels (H / M / L) dB(A) 32 / 29 / 25 35 / 34 / 32 38 / 35 / 32 Sound Pressure Levels (H / M / L) dB(A) 40 / 37 / 35 43 / 40 / 36
Sound Power Levels (H / M / L) dB(A) 47 / 44 / 41 50 / 48 / 47 52 / 50 / 47 Sound Power Levels (H / M / L) dB(A) 56 / 51 / 48 59 / 53 / 50
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50
Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
Model Name PT-UUC (Grill), PT-UUD (Panel) PT-UUC (Grill), PT-UUD (Panel) PT-UUC (Grill), PT-UUD (Panel) Model Name PT-UUC (Grill), PT-UUD (Panel) PT-UUC (Grill), PT-UUD (Panel)
Exterior Color Noble White Noble White Noble White Exterior Color Noble White Noble White
Decoration Decoration
Panel RAL Code RAL 9003 RAL 9003 RAL 9003 Panel RAL Code RAL 9003 RAL 9003
(Accessory) Net Dimensions mm 1,100 x 34 x 500 1,100 x 34 x 500 1,100 x 34 x 500 (Accessory) Net Dimensions mm 1,420 x 34 x 500 1,420 x 34 x 500
(W x H x D) (W x H x D)
Net Weight kg 4.6 / 5.3 4.6 / 5.3 4.6 / 5.3 Net Weight kg 5.5 / 6.5 5.5 / 6.5

Note : 1. Performance tested under EN14511 Note : 1. Performance tested under EN14511
2. Capacities are based on the following conditions 2. Capacities are based on the following conditions
- Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero
3. Due to our policy of innovation, some specifications may be changed without notification 3. Due to our policy of innovation, some specifications may be changed without notification

Accessories Accessories
Chassis ARNU07GTUB4 ARNU09GTUB4 ARNU12GTUB4 Chassis ARNU18GTTB4 ARNU24GTTB4
Drain Pump ○ Drain Pump ○
Cassette Cover - Cassette Cover -
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
EEV Kit PRGK024A0 EEV Kit -
Independent Power Module PRIP0 Independent Power Module PRIP0
Robot Cleaner - Robot Cleaner -
Pre Filter (washable) ○ Pre Filter (washable) ○
Ion Generator - Ion Generator -
CO2 Sensor - CO2 Sensor -
Ventilation Kit - Ventilation Kit -
IR Receiver - IR Receiver -
Zone Controller - Zone Controller -
PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible), PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible),
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus) PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus)
External Input (1 point) ○ External Input (1 point) ○
Wi-Fi PWFMDD200 Wi-Fi PWFMDD200

※ ○ : Applied, - : Not applied ※ ○ : Applied, - : Not applied


Option : Refer to model name in table Option : Refer to model name in table
1) Available from April 2020 1) Available from April 2020

130 / 131
INDOOR UNIT _ CEILING MOUNTED ROUND CASSETTE INDOOR UNIT _ CEILING MOUNTED ROUND CASSETTE _ KEY FEATURES

NEW DESIGN
Slim and Compact design Visible air flow
CEILING MOUNTED Reduce the height of the body by 15% save space and With crystal vein for 6-step precision control, you can send
maximize the openness of the interior space. cool / heated air wherever you want.
ROUND CASSETTE Other Brand LG Round Cassette Other Brand LG Round Cassette

INDOOR
UNITS
384mm
330mm

15% less body height makes


room more higher Crystal Vein
※ Product : 48 kBtu
Wind direction Wind direction
control ❶ ❷ ❸ control ❶ ❷ ❸ ❹ ❺ ❻

Minimal exposure design Powerful and Quiet air flow


Pipes are brought together in one place to minimize exposure. 3D fan increases airflow by 5% and noise reduction
Hanger covers hide installations to add a clean look. technology makes a quieter, more comfortable space.
Other Brand LG Round Cassette Full 3D Fan, Air flow rate 5% ↑ Full 3D Fan, Low noise

Talking
❶ Drain Pipe Library 50 dB(A) Office
40 dB(A) 55 dB(A)
LG Vacuum
Round CST Cleaner
39 dB(A) 70 dB(A)
Previous New
(4 Way) (Round) ※ 48 kBtu, Low flow rate

❷ Refrigerant Pipe ❶ Piping in One Direction Only

❸ Exposed Hanger ❷ Hanger Cover Normal communication Library Noise level 40dB(A)
Noise level 50dB(A)

Features & Benefits Key Applications


• Luxury round design can make a luxurious space with a round design • Retail Perfect round air flow 30% Faster in cooling
considering side view. • Restaurant Perfect round flow without blind spots. Larger airflow rate, cooling rate is faster than 30%.
• Perfect round air flow without blind spots. • Office
Other Brand LG Round Cassette
• Hotel

Cassette Round
Smart Wi-Fi O
Energy Efficiency Human Detect Sensor - Other Brand LG Round Cassette
Drain Pump O
Sleep Mode O
Timer (on / off) O
Comfort
Timer (weekly) O
Two Thermistor Control O
Group Control O Set temperature reach time 18 minutes Set temperature reach time 12 minutes
(Height 1.1m) (Height 1.1m)

※ Based on test results from LG chamber, this image is designed to help customers
understand. Experimental environment: height 3.2m, 48 kBtu, cooling mode,
3-way airflow with blind spot. Perfect circular airflow without blind spots. high flow rate, horizontal air flow direction

132 / 133
INDOOR UNIT _ CEILING MOUNTED ROUND CASSETTE _ SPECIFICATION

ROUND CEILING CASSETTE


ARNU24GTYA4 / ARNU36GTYA4
ARNU48GTYA4

INDOOR
Available from JUNE 2020

UNITS
Model Unit ARNU24GTYA4 ARNU36GTYA4 ARNU48GTYA4
Cooling Capacity kW 7.1 10.6 14.1
Heating Capacity kW 8.0 11.9 15.9
Power Input
Nominal W 44 / 36 / 29 63 / 47 / 36 98 / 70 / 44
(H / M / L)
Dimensions Body mm 1,050 x 330 x 1,050 1,050 x 330 x 1,050 1,050 x 330 x 1,050
(W x H x D) Shipping mm 1,137 x 395 x 1,132 1,137 x 395 x 1,132 1,137 x 395 x 1,132
Type 3D Turbo Fan 3D Turbo Fan 3D Turbo Fan
Motor Output x Number W 157 x 1 157 x 1 157 x 1
Fan
Air Flow Rate (H/M/L) m3/min 22 / 21 / 19 27 / 24 / 21 32 / 28 / 23
Motor Type BLDC BLDC BLDC
Air Filter Long life Long life Long life
Liquid Side mm (inch) Ø9.52 (3/8) Ø9.52 (3/8) Ø9.52 (3/8)
Pipe
Gas Side mm (inch) Ø15.88 (5/8) Ø15.88 (5/8) Ø15.88 (5/8)
Connections
Drain Pipe(Internal Dia.) mm (inch) Ø25 (1) Ø25 (1) Ø25 (1)
Weight Body kg 30 30 30
Sound Pressure Level (H / M / L) dB(A) 39 / 37 / 34 43 / 39 / 37 47 / 44 / 39
Sound Power Level (H / M / L) dB(A) 48 / 46 / 43 52 / 48 / 46 56 / 53 / 48
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
Communication Cable mm2 x No. 1.0~1.5 x 2C 1.0~1.5 x 2C 1.0~1.5 x 2C

Note : 1. Performance tested under EN14511


2. Capacities are based on the following conditions
- Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero
3. Due to our policy of innovation, some specifications may be changed without notification

Accessories
Chassis ARNU07GM1A4 ARNU09GM1A4 ARNU12GM1A4
Drain Pump ○
Cassette Cover -
Refrigerant Leakage Detector PRLDNVS0
EEV Kit -
Independent Power Module PRIP0
Robot Cleaner -
Pre Filter (washable) ○
Ion Generator -
CO2 Sensor -
Ventilation Kit -
IR Receiver -
Zone Controller -
PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible),
Dry Contact (with additional accessory)
PDRYCB320 (Universal input ), PDRYCB400 (2 points input), PDRYCB500 (Modbus)
1)

External Input (1 Point) ○


Wi-Fi PWFMDD200
Human detection sensor -
Floor Temperature Sensor -
Air cleaning kit -
Elevation Grille -

※ ○ : Applied, - : Not applied


Option : Refer to model name in table
1) Available from April 2020

134 / 135
INDOOR UNIT _ CEILING CONCEALED DUCT INDOOR UNIT _ CEILING CONCEALED DUCT _ KEY FEATURES

SMART ENERGY EFFICIENCY


Wi-Fi Control External Static Pressure (ESP) Control
CEILING Anytime, anywhere access with LG ThinQ mobile app User has easy access to air volume selection via remote
controller using the ESP control function. The BLDC

CONCEALED DUCT LG ThinQ motor can control fan speed and air volume. No additional
accessories are necessary to control air flow.

INDOOR
Search “LG ThinQ” on Google market or Appstore then

UNITS
LG ThinQ download the app.
E.S.P. E.S.P.
Control Control

Comfort Cooling / Comfort Cooling /

CEILING CONCEALED CASSETTE


Wi-Fi Heating Heating

Static Pressure 11-step Control


Depending on the installation environment, LG's
ceiling concealed duct controls the static pressure
with 11-steyps to provide maximized comfort to any
environment.

LG ThinQ Conventional New

1 step
Static Pressure
Low Setting

Easy Registration and Log-in


Follow the easy set-up steps that will activate LG ThinQ’s user-friendly features.
11 steps
Static Pressure
Power Setting

Energy Monitoring
Accumulated electric energy of the indoor unit can be
identified with wired remote control, as well as with
the central controller. This function is an advantage for
energy management.

Features & Benefits Key Applications


Install Scene Apply for multistory building
• Easy and flexible duct adjusts air volume with External Static Pressure (ESP) • Office 100kWh
control fuction • Hotel
Watt PDI
• Minimalist visibility (hidden within ceiling) to blend seamlessly into any interior • Retail Meter
• Residential building Total Power
Input

Simple operation for various functions Premium Wired Total accumulated


Remote Controller electric energy 20kWh
595kWh

Duct High Middle Low 50kWh


Smart Wi-Fi ○ ○ ○
Energy Efficiency E.S.P Control ○ ○ ○ Standard Wired Total accumulated
Drain Pump ○ ○ ○ Remote Controller electric energy 30kWh
Timer (on / off) ○ ○ ○ On/Off, Current Temp Mode, Set Temp Vane Control 3,977kWh

Comfort Timer (weekly) ○ ○ ○


* Outdoor unit's accumulated electric energy / using rate of individual indoor unit + indoor
Two Thermistor Control ○ ○ ○ unit's accumulated electric energy is displayed in wired remote controller, only when
Group Control ○ ○ ○ central controller, digital integrating electricity meter and PDI are installed and PDI,
outdoor unit and indoor unit are connected with power wire. Only total accumulated
※ ○ : Applied, - : Not applied electric energy is displayed in standard wired remote controller. In premium wired remote
controller, that are displayed into week / month / year.

136 / 137
INDOOR UNIT _ CEILING CONCEALED DUCT _ KEY FEATURES

COMFORT
Multiple Room Operation Minimized Height
Using a spiral duct (embedded or flexible type) and New mid-static ducts provide ideal solution for installation
stream chamber, it is possible to operate cooling / heating in limited space.
for several rooms simultaneously.

INDOOR
UNITS
270mm

8 / 10kW 12.5kW
380
mm
298

CEILING CONCEALED CASSETTE


mm

270 270
mm mm

Conventional New Conventional New

Filter Alert Two Thermistors Control


The alarm is activated when the filter needs to be cleaned, The indoor temperature can be checked using the thermi-
and the time remaining for cleaning is displayed on the stors in the remote controller as well as from the indoor
screen. unit. There may be a significant difference between ceiling
and floor air temperature. Two thermistors can optimise in-
Remain Time Until Indoor Filter Cleaning + Alarm
door air temperature for a more comfortable environment.

Indoor Unit Thermistor


Standard Wired
Remote Controller

Remain time until indoor filter cleaning 2400hr.

Premium Wired
Remote Controller
Remote Controller Thermistor
Remain time until indoor filter cleaning 1729hr.

1 Point External Input (On / Off Control)


Flexible Installation (Low Static Duct Only) Indoor unit can be controlled by external devices without dry
The low static duct allows the air intake at the rear or contact, so customer can save cost of installation.
bottom under specific installation conditions.
Connection between an indoor unit and external devices directly
Not Necessary
Air intake at the rear or bottom
Motion Detector
Sensor

Not Necessary
for Dry Contact

Cost Savings

Key Tag

* In case of needing more functions beside on / off control, a dry contact is required to be installed.

138 / 139
INDOOR UNIT _ CEILING CONCEALED DUCT _ SPECIFICATION

MID STATIC MID STATIC


ARNU07GM1A4 / ARNU09GM1A4 ARNU28GM2A4 / ARNU36GM2A4
ARNU12GM1A4 / ARNU15GM1A4 ARNU42GM2A4 / ARNU48GM3A4
ARNU18GM1A4 / ARNU24GM1A4 ARNU54GM3A4

INDOOR
UNITS
CEILING CONCEALED CASSETTE
Model Unit ARNU07GM1A4 ARNU09GM1A4 ARNU12GM1A4 ARNU15GM1A4 ARNU18GM1A4 ARNU24GM1A4 Model Unit ARNU28GM2A4 ARNU36GM2A4 ARNU42GM2A4 ARNU48GM3A4 ARNU54GM3A4
Cooling Capacity kW 2.2 2.8 3.6 4.5 5.6 7.1 Cooling Capacity kW 8.2 10.6 12.3 14.1 15.8
Heating Capacity kW 2.5 3.2 4.0 5.0 6.3 8.0 Heating Capacity kW 9.2 11.9 13.8 15.9 18.0
Power Input Power Input
Nominal W 39 / 30 / 25 40 / 32 / 26 46 / 38 / 31 67 / 53 / 46 85 / 63 / 55 91 / 74 / 58 Nominal W 123 / 81 / 57 184 / 123 / 81 231 / 162 / 111 172 / 105 / 65 260 / 215 / 172
(H / M / L) (H / M / L)
Dimensions Body mm 900 x 270 x 700 900 x 270 x 700 900 x 270 x 700 900 x 270 x 700 900 x 270 x 700 900 x 270 x 700 Dimensions Body mm 1,250 x 270 x 700 1,250 x 270 x 700 1,250 x 270 x 700 1,250 x 360 x 700 1,250 x 360 x 700
(W x H x D) Shipping mm 1,100 x 338 x 773 1,100 x 338 x 773 1,100 x 338 x 773 1,100 x 338 x 773 1,100 x 338 x 773 1,100 x 338 x 773 (W x H x D) Shipping mm 1,450 x 338 x 773 1,450 x 338 x 773 1,450 x 338 x 773 1,450 x 428 x 773 1,450 x 428 x 773
Type Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan Type Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan
Motor Output x Number W x No. 136 x 1 136 x 1 136 x 1 136 x 1 136 x 1 136 x 1 Motor Output x Number W x No. 350 x 1 350 x 1 350 x 1 350 x 1 350 x 1
Air Flow Rate (H / M / L) m³/min 9.0 / 7.5 / 6.0 9.5 / 7.5 / 6.0 11.0 / 9.0 / 7.0 16.0 / 12.0 / 9.0 17.0 / 14.5 / 12.0 19.0 / 16.0 / 14.0 Air Flow Rate (H / M / L) m³/min 28.0 / 24.0 / 21.0 32.0 / 28.0 / 24.0 38.0 / 33.0 / 28.0 40.0 / 34.0 / 28.0 50.0 / 45.0 / 40.0
External Static Pressure External Static Pressure
mmAq (Pa) 6 (59) 6 (59) 6 (59) 6 (59) 6 (59) 6 (59) mmAq (Pa) 6 (59) 6 (59) 6 (59) 6 (59) 6 (59)
Fan (High Mode) Fan (High Mode)
Air Flow Rate (H / M / L) Air Flow Rate (H / M / L)
m³/min 9.0 / 7.5 / 6.0 9.5 / 7.5 / 6.0 11.0 / 9.0 / 7.0 16.0 / 12.0 / 9.0 17.0 / 14.5 / 12.0 19.0 / 16.0 / 14.0 m³/min 28.0 / 24.0 / 21.0 32.0 / 28.0 / 24.0 38.0 / 33.0 / 28.0 40.0 / 34.0 / 28.0 50.0 / 45.0 / 40.0
(Standard Mode) (Standard Mode)
External Static Pressure External Static Pressure
mmAq (Pa) 2.5 (25) 2.5 (25) 2.5 (25) 2.5 (25) 2.5 (25) 2.5 (25) mmAq (Pa) 5 (49) 5 (49) 5 (49) 5 (49) 5 (49)
(Standard Mode) (Standard Mode)
Motor Type BLDC BLDC BLDC BLDC BLDC BLDC Motor Type BLDC BLDC BLDC BLDC BLDC
Air Filter Pre Filter Pre Filter Pre Filter Pre Filter Pre Filter Pre Filter Air Filter Pre Filter Pre Filter Pre Filter Pre Filter Pre Filter
Liquid Side mm (inch) Ø6.35 (1/4) Ø6.35 (1/4) Ø6.35 (1/4) Ø6.35 (1/4) Ø6.35 (1/4) Ø9.52 (3/8) Liquid Side mm (inch) Ø9.52 (3/8) Ø9.52 (3/8) Ø9.52 (3/8) Ø9.52 (3/8) Ø9.52 (3/8)
Pipe Pipe
Gas Side mm (inch) Ø12.7 (1/2) Ø12.7 (1/2) Ø12.7 (1/2) Ø12.7 (1/2) Ø12.7 (1/2) Ø15.88 (5/8) Gas Side mm (inch) Ø15.88 (5/8) Ø15.88 (5/8) Ø15.88 (5/8) Ø15.88 (5/8) Ø19.05 (3/4)
Connections Connections
Drain Pipe (Internal Dia.) mm (inch) 25 (1) 25 (1) Ø25 (1) Ø25 (1) Ø25 (1) Ø25 (1) Drain Pipe (Internal Dia.) mm (inch) Ø25 (1) Ø25 (1) Ø25 (1) Ø25 (1) Ø25 (1)
Weight Body kg 25.5 25.5 25.5 25.5 25.5 26.5 Weight Body kg 38.0 38.0 39.5 44.0 44.0
Sound Pressure Levels (H / M / L) dB(A) 26 / 24 / 23 27 / 25 / 23 27 / 25 / 23 30 / 27 / 23 31 / 28 / 25 32 / 29 / 26 Sound Pressure Levels (H / M / L) dB(A) 36 / 34 / 33 37 / 36 / 34 38 / 37 / 36 39 / 37 / 35 42 / 40 / 39
Sound Power Levels (H / M / L) dB(A) 55 / 54 / 51 55 / 54 / 52 56 / 54 / 52 59 / 57 / 55 59 / 57 / 55 59 / 58 / 56 Sound Power Levels (H / M / L) dB(A) 59 / 57 / 55 60 / 59 / 57 62 / 61 / 60 63 / 60 / 59 65 / 64 / 62
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C

Note : 1. Performance tested under EN14511 Note : 1. Performance tested under EN14511
2. Capacities are based on the following conditions 2. Capacities are based on the following conditions
- Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero
3. Due to our policy of innovation, some specifications may be changed without notification 3. Due to our policy of innovation, some specifications may be changed without notification

Accessories Accessories
Chassis ARNU07GM1A4 ARNU09GM1A4 ARNU12GM1A4 ARNU15GM1A4 ARNU18GM1A4 ARNU24GM1A4 Chassis ARNU28GM2A4 ARNU36GM2A4 ARNU42GM2A4 ARNU48GM3A4 ARNU54GM3A4
Drain Pump ○ Drain Pump ○
Cassette Cover - Cassette Cover -
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
EEV Kit PRGK024A0 (~5.6kW) EEV Kit -
Independent Power Module PRIP0 Independent Power Module PRIP0
Robot Cleaner - Robot Cleaner -
Pre Filter (washable) ○ Pre Filter (washable) ○
Ion Generator - Ion Generator -
CO2 Sensor - CO2 Sensor -
Ventilation Kit - Ventilation Kit -
IR Receiver PWLRVN000 IR Receiver PWLRVN000
Zone Controller ABZCA Zone Controller ABZCA
PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible), PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible),
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus) PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus)
External Input (1 point) ○ External Input (1 point) ○
Wi-Fi PWFMDD200 Wi-Fi PWFMDD200

※ ○ : Applied, - : Not applied ※ ○ : Applied, - : Not applied


Option : Refer to model name in table Option : Refer to model name in table
1) Available from April 2020 1) Available from April 2020

140 / 141
INDOOR UNIT _ CEILING CONCEALED DUCT _ SPECIFICATION

HIGH STATIC LOW STATIC


ARNU76GB8A4 / ARNU96GB8A4 ARNU05GL1G4 / ARNU07GL1G4
ARNU09GL1G4

INDOOR
UNITS
CEILING CONCEALED CASSETTE
Model Unit ARNU76GB8A4 ARNU96GB8A4 Model Unit ARNU05GL1G4 ARNU07GL1G4 ARNU09GL1G4
Cooling Capacity kW 22.4 28.0 Cooling Capacity kW 1.7 2.2 2.8
Heating Capacity kW 25.2 31.5 Heating Capacity kW 1.9 2.5 3.2
Power Input Power Input
Nominal W 765 / 500 / 500 800 / 750 / 750 Nominal W 29 / 26 / 24 31 / 28 / 24 39 / 29 / 24
(H / M / L) (H / M / L)
Dimensions Body mm 1,562 x 460 x 688 1,562 x 460 x 688 Dimensions Body mm 700 x 190 x 700 700 x 190 x 700 700 x 190 x 700
(W x H x D) Shipping mm 1,806 x 537 x 825 1,806 x 537 x 825 (W x H x D) Shipping mm 862 x 255 x 781 862 x 255 x 781 862 x 255 x 781
Type Sirocco Fan Sirocco Fan Type Sirocco Fan Sirocco Fan Sirocco Fan
Motor Output x Number W x No. 375 x 2 375 x 2 Motor Output x Number W x No. 19 x 1 19 x 1 19 x 1
Air Flow Rate (H / M / L) Air Flow Rate (H / M / L)
m³/min 60.0 / 50.0 / 50.0 72.0 / 64.0 / 64.0 m³/min 6.7 / 6.2 / 5.5 7.5 / 6.5 / 5.5 9.0 / 7.0 / 5.5
(High Mode-Factory Set) (High Mode-Factory Set)
External Static Pressure External Static Pressure
Fan mmAq (Pa) 22 (216) 22 (216) Fan mmAq (Pa) 2.54 (25) 2.54 (25) 2.54 (25)
(High Mode) (High Mode)
Air Flow Rate (H / M / L) Air Flow Rate (H / M / L)
m³/min 64.0 / 50.0 / 50.0 76.0 / 64.0 / 64.0 m³/min 6.7 / 6.2 / 5.5 7.5 / 6.5 / 5.5 9.0 / 7.0 / 5.5
(Standard Mode) (Standard Mode)
External Static Pressure External Static Pressure
mmAq (Pa) 15 (147) 15 (147) mmAq (Pa) 0 (0) 0 (0) 0 (0)
(Standard Mode) (Standard Mode)
Motor Type BLDC BLDC Motor Type BLDC BLDC BLDC
Air Filter Pre Filter Pre Filter Air Filter Pre Filter Pre Filter Pre Filter
Liquid Side mm (inch) Ø9.52 (3/8) Ø9.52 (3/8) Liquid Side mm (inch) Ø6.35 (1/4) Ø6.35 (1/4) Ø6.35 (1/4)
Pipe Pipe
Gas Side mm (inch) Ø19.05 (3/4) Ø22.2 (7/8) Gas Side mm (inch) Ø12.7 (1/2) Ø12.7 (1/2) Ø12.7 (1/2)
Connections Connections
Drain Pipe (Internal Dia.) mm (inch) Ø25 (1) Ø25 (1) Drain Pipe (Internal Dia.) mm (inch) Ø25 (1) Ø25 (1) Ø25 (1)
Weight Body kg 87.0 87.0 Weight Body kg 17.5 17.5 17.5
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 Sound Pressure Levels (H / M / L) dB(A) 25 / 24 / 22 26 / 24 / 22 28 / 25 / 22
Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Sound Power Levels (H / M / L) dB(A) 48 / 46 / 45 50 / 47 / 45 53 / 49 / 45
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
Note : 1. Performance tested under EN14511
2. Capacities are based on the following conditions Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
- Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero Note : 1. Performance tested under EN14511
3. Due to our policy of innovation, some specifications may be changed without notification 2. Capacities are based on the following conditions
- Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero
3. Due to our policy of innovation, some specifications may be changed without notification

Accessories Accessories
Chassis ARNU76GB8A4 ARNU96GB8A4 Chassis ARNU05GL1G4 ARNU07GL1G4 ARNU09GL1G4
Drain Pump ○ Drain Pump ○
Cassette Cover - Cassette Cover -
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
EEV Kit ○ EEV Kit PRGK024A0
Independent Power Module PRIP0 Independent Power Module PRIP0
Robot Cleaner - Robot Cleaner -
Pre Filter (washable) ○ Pre Filter (washable) ○
Ion Generator - Ion Generator -
CO2 Sensor - CO2 Sensor -
Ventilation Kit - Ventilation Kit -
IR Receiver PWLRVN000 IR Receiver PWLRVN000
Zone Controller ABZCA Zone Controller ABZCA
PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible), PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible),
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus) PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus)
External Input (1 point) ○ External Input (1 point) ○
Wi-Fi PWFMDD200 Wi-Fi PWFMDD200

※ ○ : Applied, - : Not applied ※ ○ : Applied, - : Not applied


Option : Refer to model name in table Option : Refer to model name in table
1) Available from April 2020 1) Available from April 2020

142 / 143
INDOOR UNIT _ CEILING CONCEALED DUCT _ SPECIFICATION

LOW STATIC LOW STATIC


ARNU12GL2G4 / ARNU15GL2G4 ARNU21GL3G4 / ARNU24GL3G4
ARNU18GL2G4

INDOOR
UNITS
CEILING CONCEALED CASSETTE
Model Unit ARNU12GL2G4 ARNU15GL2G4 ARNU18GL2G4 Model Unit ARNU21GL3G4 ARNU24GL3G4
Cooling Capacity kW 3.6 4.5 5.6 Cooling Capacity kW 6.2 7.1
Heating Capacity kW 4.0 5.0 6.3 Heating Capacity kW 7.0 8.0
Power Input Power Input
Nominal W 41 / 34 / 29 56 / 41 / 34 71 / 56 / 41 Nominal W 72 / 53 / 48 103 / 63 / 48
(H / M / L) (H / M / L)
Dimensions Body mm 900 x 190 x 700 900 x 190 x 700 900 x 190 x 700 Dimensions Body mm 1,100 x 190 x 700 1,100 x 190 x 700
(W x H x D) Shipping mm 1,062 x 255 x 781 1,062 x 255 x 781 1,062 x 255 x 781 (W x H x D) Shipping mm 1,262 x 255 x781 1,262 x 255 x781
Type Sirocco Fan Sirocco Fan Sirocco Fan Type Sirocco Fan Sirocco Fan
Motor Output x Number W x No. 19 x 1, 5 x 1 19 x 1, 5 x 1 19 x 1, 5 x 1 Motor Output x Number W x No. 19 x 2 19 x 2
Air Flow Rate (H / M / L) Air Flow Rate (H / M / L)
m³/min 10.0 / 8.5 / 7.0 12.5 / 10.0 / 8.5 15.0 / 12.5 / 10.0 m³/min 17.5 / 14.0 / 12.0 20.0 / 16.0 / 12.0
(High Mode-Factory Set) (High Mode-Factory Set)
External Static Pressure External Static Pressure
Fan mmAq (Pa) 2.54 (25) 2.54 (25) 2.54 (25) Fan mmAq (Pa) 2.54 (25) 2.54 (25)
(High Mode) (High Mode)
Air Flow Rate (H / M / L) Air Flow Rate (H / M / L)
m³/min 10.0 / 8.5 / 7.0 12.5 / 10.0 / 8.5 15.0 / 12.5 / 10.0 m³/min 17.5 / 14.0 / 12.0 20.0 / 16.0 / 12.0
(Standard Mode) (Standard Mode)
External Static Pressure External Static Pressure
mmAq (Pa) 0 (0) 0 (0) 0 (0) mmAq (Pa) 0 (0) 0 (0)
(Standard Mode) (Standard Mode)
Motor Type BLDC BLDC BLDC Motor Type BLDC BLDC
Air Filter Pre Filter Pre Filter Pre Filter Air Filter Pre Filter Pre Filter
Liquid Side mm (inch) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Liquid Side mm (inch) Ø9.52 (3/8) Ø9.52 (3/8)
Pipe Pipe
Gas Side mm (inch) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Gas Side mm (inch) Ø15.88 (5/8) Ø15.88 (5/8)
Connections Connections
Drain Pipe (Internal Dia.) mm (inch) Ø25 (1) Ø25 (1) Ø25 (1) Drain Pipe (Internal Dia.) mm (inch) Ø25 (1) Ø25 (1)
Weight Body kg 23.0 23.0 23.0 Weight Body kg 27.0 27.0
Sound Pressure Levels (H / M / L) dB(A) 30 / 27 / 25 33 / 30 / 28 35 / 32 / 29 Sound Pressure Levels (H / M / L) dB(A) 35 / 29 / 28 36 / 33 / 28
Sound Power Levels (H / M / L) dB(A) 50 / 47 / 46 54 / 51 / 47 56 / 54 / 51 Sound Power Levels (H / M / L) dB(A) 59 / 55 / 54 63 / 59 / 55
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50
Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C

Note : 1. Performance tested under EN14511 Note : 1. Performance tested under EN14511
2. Capacities are based on the following conditions 2. Capacities are based on the following conditions
- Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero
3. Due to our policy of innovation, some specifications may be changed without notification 3. Due to our policy of innovation, some specifications may be changed without notification

Accessories Accessories
Chassis ARNU12GL2G4 ARNU15GL2G4 ARNU18GL2G4 Chassis ARNU21GL3G4 ARNU24GL3G4
Drain Pump ○ Drain Pump ○
Cassette Cover - Cassette Cover -
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
EEV Kit - EEV Kit PRGK024A0
Independent Power Module PRIP0 Independent Power Module PRIP0
Robot Cleaner - Robot Cleaner -
Pre Filter (washable) ○ Pre Filter (washable) ○
Ion Generator - Ion Generator -
CO2 Sensor - CO2 Sensor -
Ventilation Kit - Ventilation Kit -
IR Receiver PWLRVN000 IR Receiver PWLRVN000
Zone Controller ABZCA Zone Controller ABZCA
PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible), PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible),
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus) PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus)
External Input (1 point) ○ External Input (1 point) ○
Wi-Fi PWFMDD200 Wi-Fi PWFMDD200

※ ○ : Applied, - : Not applied ※ ○ : Applied, - : Not applied


Option : Refer to model name in table Option : Refer to model name in table
1) Available from April 2020 1) Available from April 2020

144 / 145
INDOOR UNIT _ CEILING CONCEALED DUCT _ SPECIFICATION

HIGH SENSIBLE HIGH SENSIBLE


ARNU07GM2A4 / ARNU09GM2A4 ARNU24GM3A4 / ARNU28GM3A4
ARNU12GM2A4 / ARNU15GM2A4 ARNU36GB8A4 / ARNU42GB8A4
ARNU18GM3A4 ARNU48GB8A4

INDOOR
UNITS
CEILING CONCEALED CASSETTE
Model Unit ARNU07GM2A4 ARNU09GM2A4 ARNU12GM2A4 ARNU15GM2A4 ARNU18GM3A4 Model Unit ARNU24GM3A4 ARNU28GM3A4 ARNU36GB8A4 ARNU42GB8A4 ARNU48GB8A4
Cooling Capacity kW 2.2 2.8 3.6 4.5 5.6 Cooling Capacity kW 7.1 8.2 10.6 12.3 14.1
Heating Capacity kW 2.5 3.2 4.0 5.0 6.3 Heating Capacity kW 8.0 9.2 11.9 13.8 15.9
Power Input Power Input
W 32 / 29 / 27 32 / 29 / 27 33 / 30 / 28 33 / 30 / 28 97 / 70 / 51 W 109 / 83 / 60 109 / 83 / 60 420 / 403 / 478 528 / 497 / 465 538 / 505 / 482
(H / M / L) (H / M / L)
Dimensions Dimensions
Body mm 1,250 × 270 × 700 1,250 × 270 × 700 1,250 × 270 × 700 1,250 × 270 × 700 1,250 × 360 × 700 Body mm 1,250 × 360 × 700 1,250 × 360 × 700 1,562 x 460 x 688 1,562 x 460 x 688 1,562 x 460 x 688
(W x H x D) (W x H x D)
Type Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan Type Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan
Motor Output x Number W x No. 350 x 1 350 x 1 350 x 1 350 x 1 500 x 1 Motor Output x Number W x No. 500 x 1 500 x 1 375 x 2 375 x 2 375 x 2
Air Flow Rate (H / M / L) Air Flow Rate (H / M / L)
(High static Mode m³/min 13.3 / 9.4 / 6.8 13.3 / 9.4 / 6.8 14.8 / 10.2 / 7.4 14.8 / 10.2 / 7.4 32.7 / 26.7 / 23.0 (High static Mode m³/min 35.5 / 30.6 / 26.2 35.5 / 30.6 / 26.2 49.0 / 37.3 / 30.2 54.2 / 41.3 / 31.8 57.2 / 43.0 / 34.0
- factory set) - factory set)
Fan Fan
External Static Pressure mmAq (Pa) 6 (59) 6 (59) 6 (59) 6 (59) 6 (59) External Static Pressure mmAq (Pa) 6 (59) 6 (59) 18 (176) 18 (176) 18 (176)
Air Flow Rate (H / M / L) Air Flow Rate (H / M / L)
m³/min 13.3 / 9.4 / 6.8 13.3 / 9.4 / 6.8 14.8 / 10.2 / 7.4 14.8 / 10.2 / 7.4 32.7 / 26.7 / 23.0 m³/min 35.5 / 30.6 / 26.2 35.5 / 30.6 / 26.2 53.7 / 49.5 / 43.9 55.6 / 50.6 / 45.0 58.0 / 52.3 / 47.3
(Standard Mode) (Standard Mode)
External Static Pressure mmAq (Pa) 5 (49) 5 (49) 5 (49) 5 (49) 5 (49) External Static Pressure mmAq (Pa) 5 (49) 5 (49) 9 (88) 9 (88) 9 (88)
Motor type BLDC BLDC BLDC BLDC BLDC Motor type BLDC BLDC BLDC BLDC BLDC
Air Filter - - - - - Air Filter - - - - -
Liquid Side mm (inch) Ø9.52 (3/8) Ø9.52 (3/8) Ø9.52 (3/8) Ø9.52 (3/8) Ø9.52 (3/8) Liquid Side mm (inch) Ø9.52 (3/8) Ø9.52 (3/8) Ø9.52 (3/8) Ø9.52 (3/8) Ø9.52 (3/8)
Pipe Pipe
Gas Side mm (inch) Ø15.88 (5/8) Ø15.88 (5/8) Ø15.88 (5/8) Ø15.88 (5/8) Ø15.88 (5/8) Gas Side mm (inch) Ø15.88 (5/8) Ø15.88 (5/8) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Connections Connections
Drain Pipe (Internal Dia.) mm (inch) 25 (1) 25 (1) 25 (1) 25 (1) 25 (1) Drain Pipe (Internal Dia.) mm (inch) 25 (1) 25 (1) 25 (1) 25 (1) 25 (1)
Net Weight kg 38 38 38 38 44 Net Weight kg 44 44 87 87 87
Sound Pressure Levels (H / M / L) dB(A) 33 / 33 / 32 33 / 33 / 32 34 / 33 / 32 34 / 33 / 32 38 / 36 / 34 Sound Pressure Levels (H / M / L) dB(A) 39 / 37 / 35 39 / 37 / 35 46 / 45 / 42 47 / 46 / 43 47 / 46 / 44
Sound Power Levels (H / M / L) dB(A) 52 / 52 / 52 52 / 52 / 52 53 / 52 / 52 53 / 52 / 52 52 / 51 / 50 Sound Power Levels (H / M / L) dB(A) 53 / 52 / 51 53 / 52 / 51 65 / 64 / 62 66 / 65 / 63 66 / 65 / 64
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
Transmission cable mm² 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Transmission cable mm² 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C

Note : 1. Due to our policy of innovation some specifications may be changed without notification. Note : 1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national code. And “Electric characteristics” chapter should be considered for electrical work and design. 2. Wiring cable size must comply with the applicable local and national code. And “Electric characteristics” chapter should be considered for electrical work and design.
Especially the power cable and circuit breaker should be selected in accordance with that. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition 3. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition
in the reverberation rooms by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation. in the reverberation rooms by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
4. Capacities are net capacities and based on the following conditions. Refer to the Outdoor Unit Specifications for calculating the real capacity. 4. Capacities are net capacities and based on the following conditions. Refer to the Outdoor Unit Specifications for calculating the real capacity.
- Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB - Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
- Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB - Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
- Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero. - Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
5. Sound levels are measured at 50Pa External Static Pressure condition. 5. Sound levels are measured at 50Pa External Static Pressure condition.
6. * : Air flow rate could be different in accordance with External Static Pressure and setting value. 6. * : Air flow rate could be different in accordance with External Static Pressure and setting value.

Accessories Accessories
Chassis ARNU07GM2A4 ARNU09GM2A4 ARNU12GM2A4 ARNU15GM2A4 ARNU18GM3A4 Chassis ARNU24GM3A4 ARNU28GM3A4 ARNU36GB8A4 ARNU42GB8A4 ARNU48GB8A4
Drain Pump ○ Drain Pump ○
Cassette Cover - Cassette Cover -
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
EEV Kit - EEV Kit -
Independent Power Module PRIP0 Independent Power Module PRIP0
Robot Cleaner - Robot Cleaner -
Pre Filter (washable) ○ Pre Filter (washable) ○
Ion Generator - Ion Generator -
CO2 Sensor - CO2 Sensor -
Ventilation Kit - Ventilation Kit -
IR Receiver PWLRVN000 IR Receiver PWLRVN000
Zone Controller ABZCA Zone Controller ABZCA
PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible), PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible),
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus) PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus)
External Input (1 point) ○ External Input (1 point) ○
Wi-Fi PWFMDD200 Wi-Fi PWFMDD200

※ ○ : Applied, - : Not applied ※ ○ : Applied, - : Not applied


Option : Refer to model name in table Option : Refer to model name in table
1) Available from April 2020 1) Available from April 2020

146 / 147
INDOOR UNIT _ CEILING CONCEALED DUCT _ KEY FEATURES INDOOR UNIT _ CEILING CONCEALED DUCT _ SPECIFICATION

FRESH AIR INTAKE FRESH AIR INTAKE UNIT


Fresh Outdoor Air Supply
The LG Fresh Air Intake Unit (FAU) is the alternative solution for ventilation, which supplies the fresh outdoor ARNU76GB8Z4 / ARNU96GB8Z4
air indoors as well as being able to cool and heat air inside simultaneously. It means the indoor space can have
positive air pressure consistently, which can block cold, hot or contaminated air from outside.

INDOOR
This allows the indoor space to have consistent postive air pressure blocking cold.

UNITS
Fresh Air Intake Unit

100%
Outdoor Air Indoor Unit Diffuser Indoor Unit Diffuser Indoor Unit Diffuser

FRESH AIR INTAKE UNIT


Model Unit ARNU76GB8Z4 ARNU96GB8Z4
Air Conditioning Cooling Capacity kW 22.4 28.0
Air Conditioning + Heating Capacity kW 21.4 26.7
Outdoor Air Supply Power Input
Nominal W 230 / 200 / 200 360 / 230 / 230
(H / M / L)
Dimensions Body mm 1,562 x 460 x 688 1,562 x 460 x 688
(W x H x D) Shipping mm 1,806 x 537 x 825 1,806 x 537 x 825
MULTI V 5 Outdoor Unit Type Sirocco Fan Sirocco Fan
Motor Output x Number W x No. 375 x 1 375 x 1
Air Flow Rate (H / M / L)
Fan m³/min 23.7 / 13.2 / 13.2 35.7 / 23.7 / 23.7
(High Mode-Factoty Set)
External Static Pressure mmAq (Pa) 22 (216) 22 (216)
Motor Type BLDC BLDC
Air Filter Long Life Filter Long Life Filter
Economic Operation Liquid Side mm (inch) Ø9.52 (3/8) Ø9.52 (3/8)
Natural outdoor air is utilized as seasons change for cost efficiency. Pipe
Gas Side mm (inch) Ø19.05 (3/4) Ø22.2 (7/8)
Connections
Drain Pipe (Internal Dia.) mm (inch) Ø25 (1) Ø25 (1)
Spring Season Autumn Season Weight Body kg 73.0 73.0
Fresh Air Intake Unit Fresh Air Intake Unit
Sound Pressure Levels (H / M / L) dB(A) 45 / 43 / 43 47 / 45 / 45
Sound Power Levels (H / M / L) dB(A) 70 / 67 / 67 72 / 70 / 70
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50
Indoor Unit Diffuser Indoor Unit Diffuser
Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
OFF OFF
Note : 1. Performance tested under EN14511
2. Capacities are based on the following conditions
Warm Air Cool Air - Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
+ + - Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero
Outdoor Air Supply Outdoor Air Supply 3. Due to our policy of innovation, some specifications may be changed without notification

CAUTION
1. Operation range (Cooling : 5°C ~ 43°C, Heating : -5°C ~ 43°C) 2. Installation of exhaust fan is recommended for a sealed room. 3. Indoor Unit Connection
MULTI V 5 Outdoor Unit MULTI V 5 Outdoor Unit
No Connection Condition Combination
Fresh air intake units only 1) The total capcity of fresh air intak unit should be 50 ~ 100% of outdoor unit.
1
are connected with outdoor units 2) The max quantity of fresh air intake is 4 units.
Mixture connection with 1) The total capacity of indoor units (Standard Indoor Unit + Fresh Air Intake Unit) should be 50 ~ 100% of outdoor unit.
2
general indoor unit and fresh intake units 2) The total capacity of fresh air intake unit should be less than 30% of the total capacity of indoor units.

Installation Scene
Accessories
Min. 2m
Chassis ARNU76GB8Z4 ARNU96GB8Z4
Drain Pump ○
Cassette Cover -
Refrigerant Leakage Detector PRLDNVS0
1/30 Slope EEV Kit -
Outlet Air Independent Power Module PRIP0
Robot Cleaner -
Pre Filter (washable) ○
Ion Generator -
CO2 Sensor -
Exhaust Air Ventilation Kit -
IR Receiver PWLRVN000
Zone Controller -
Inlet Hood Intake Air Duct Fresh Air Intake Unit PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible),
Dry Contact (with additional accessory)
Exhaust Fan Door PDRYCB320 (Universal input ), PDRYCB400 (2 points input), PDRYCB500 (Modbus)
1)

External Input (1 point) ○


Wi-Fi PWFMDD200

※ ○ : Applied, - : Not applied


Option : Refer to model name in table
1) Available from April 2020

148 / 149
INDOOR _ CEILING & FLOOR CONVERTIBLE UNIT CEILING SUSPENDED UNIT INDOOR _ CEILING & FLOOR CONVERTIBLE UNIT CEILING SUSPENDED UNIT _ KEY FEATURES

SMART COMFORT(CEILING SUSPENDED UNIT)


Wi-Fi Control Differentiated Design
CEILING & FLOOR CONVERTIBLE UNIT Access your air conditioner anytime and from anywhere. Modern elegance design with V-shape and black vane is
appropriate for any commercial space. It received iF Design
LG ThinQ
CEILING SUSPENDED UNIT Search “LG ThinQ” on Google market or Appstore then
Award.

INDOOR
UNITS
LG ThinQ download the app.

Access your air conditioner anytime and from anywhere

LG ThinQ
Wi-Fi

CEILING & FLOOR CONVERTIBLE UNIT CEILING SUSPENDED UNIT


Easy Registration and Log-in
Powerful Cooling & Heating
Follow the easy set-up steps that will
High ceiling mode provides powerful cooling and heating up to
activate SmartThinQ’s impressive feature. 4.2m in height from floor, 15m away from ceiling.

COMFORT(CONVERTIBLE UNIT)
One Touch & 2 Piece Filter
Flexible Easy in / out filter structure as well as a simplified two-piece
The ceiling and floor models can be installed either on the filter, which slides out for easy cleaning and maintenance.
ceiling or on the floor.

Features & Benefits Key Applications


Air flow Direction Control One Touch Filter

• Modern design with V-shape and black vane • Retail Vertical air flow direction can be adjusted using remote controller,
• Powerful air speed and volume can reach up to 15m • Shop and horizontal Air flow direction can be adjusted manually.
• Restaurant Two Thermistors Control
Users can purchase a wired remote controller that includes
a second thermistor, allowing for temperature checks from
Horizontal Vertical
100 °
93 ° multiple locations.
Ceilings Ceiling & Floor Convertible Unit Ceiling Suspended Unit
Smart Wi-Fi ○ ○ 80 °
Close 63 ° Close
Fast Cooling & Heating Jet Cool ○ ○
Cooling Heating
Sleep mode ○ ○ Two
Thermistors

Comfort
Timer (on / off)
Timer (weekly)




Filter Change Alarm Indoor Unit
Remote
Controller Thermistor
The filter change alarm informs you when the unit has been
Two thermistor control
Group control




operating for 2,400hours. 15M
15M
Thermistor

※ ○ : Applied, - : Not applied

One Touch Filter Velocity in Stn Frame


Contour 1
2,000e+001
Filter Change Alarm
ANSYS
R15.0

1,800e+001
1,600e+001
1,400e+001
1,200e+001
1,000e+001
8,000e+000
150 / 151
6,000e+000
4,000e+000
2,000e+000
Velocity in Stn Frame 0,000e+000 ANSYS
Contour 1 [m s^-1] R15. 0
2,000e+00 1
1,800e+00 1
1,600e+00 1
INDOOR _ CEILING & FLOOR CONVERTIBLE UNIT CEILING SUSPENDED UNIT _ SPECIFICATION

CEILING & FLOOR CONVERTIBLE UNIT CEILING SUSPENDED UNIT


ARNU09GVEA4 / ARNU12GVEA4 ARNU18GV1A4 / ARNU24GV1A4
ARNU36GV2A4 / ARNU48GV2A4

INDOOR
UNITS
CEILING & FLOOR CONVERTIBLE UNIT CEILING SUSPENDED UNIT
Model Unit ARNU09GVEA4 ARNU12GVEA4 Model Unit ARNU18GV1A4 ARNU24GV1A4 ARNU36GV2A4 ARNU48GV2A4
Cooling Capacity kW 2.8 3.6 Cooling Capacity kW 5.6 7.1 10.6 14.1
Heating Capacity kW 3.2 4.0 Heating Capacity kW 6.3 8.0 11.9 15.9
Power Input Power Input
Nominal W 19 / 15 / 11 28 / 19 / 15 Nominal W 23 / 20 / 17 25 / 21 / 17 84 / 77 / 66 91 / 79 / 66
(H / M / L) (H / M / L)
Exterior Color Morning Fog Morning Fog Exterior Color Morning Fog Morning Fog Morning Fog Morning Fog
RAL Code RAL 9001 RAL 9001 RAL Code RAL 9001 RAL 9001 RAL 9001 RAL 9001
Dimensions Body mm 900 x 490 x 200 900 x 490 x 200 Dimensions Body mm 1,200 x 235 x 690 1,200 x 235 x 690 1,600 x 235 x 690 1,600 x 235 x 690
(W x H x D) Shipping mm 975 x 279 x 562 975 x 279 x 562 (W x H x D) Shipping mm 1,315 x 320 x 772 1,315 x 320 x 772 1,715 x 320 x 772 1,715 x 320 x 772
Type Cross Flow Fan Cross Flow Fan Type Cross Flow Fan Cross Flow Fan Cross Flow Fan Cross Flow Fan
Motor Output x Number W x No. 27 x 1 27 x 1 Motor Output x Number W x No. 85.9 x 1 85.9 x 1 125 x 1 125 x 1
Fan
Fan m³/min 7.6 / 6.9 / 6.2 9.2 / 7.6 / 6.9 Air Flow Rate (H / M / L) m³/min 13.5 / 12.5 / 12.0 14.0 / 13.0 / 12.0 27.0 / 24.0 / 20.0 29.0 / 24.0 / 20.0
Air Flow Rate (H / M / L)
cfm 268 / 244 / 219 325 / 268 / 244 Motor Type BLDC BLDC BLDC BLDC
Motor Type BLDC BLDC Air Filter Pre Filter Pre Filter Pre Filter Pre Filter
Air Filter Pre Filter Pre Filter Liquid Side mm (inch) Ø6.35 (1/4) Ø9.52 (3/8) Ø9.52 (3/8) Ø9.52 (3/8)
Pipe
Liquid Side mm (inch) Ø6.35 (1/4) Ø6.35 (1/4) Gas Side mm (inch) Ø12.7 (1/2) Ø15.88 (5/8) Ø15.88 (5/8) Ø15.88 (5/8)
Pipe Connections
Gas Side mm (inch) Ø12.7 (1/2) Ø12.7 (1/2) Drain Pipe (Internal Dia.) mm (inch) Ø16 (5/8) Ø16 (5/8) Ø16 (5/8) Ø16 (5/8)
Connections
Drain Pipe (Internal Dia.) mm (inch) Ø16 (5/8) Ø16 (5/8) Weight Body kg 29.0 29.0 37.0 37.0
Weight Body kg 13.3 13.3 Sound Pressure Levels (H / M / L) dB(A) 36 / 34 / 33 37 / 35 / 33 48 / 46 / 44 49 / 47 / 44
Sound Pressure Levels (H / M / L) dB(A) 36 / 32 / 28 38 / 36 / 30 Sound Power Levels (H / M / L) dB(A) 61 / 59 / 56 62 / 59 / 56 68 / 66 / 64 68 / 67 / 66
Sound Power Levels (H / M / L) dB(A) 55 / 51 / 45 56 / 55 / 49 Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
Note : 1. Performance tested under EN14511
2. Capacities are based on the following conditions
Note : 1. Performance tested under EN14511
- Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
2. Capacities are based on the following conditions
- Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero
- Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
3. Due to our policy of innovation, some specifications may be changed without notification
- Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero
3. Due to our policy of innovation, some specifications may be changed without notification

Accessories Accessories
Chassis ARNU09GVEA4 ARNU12GVEA4 Chassis ARNU18GV1A4 ARNU24GV1A4 ARNU36GV2A4 ARNU48GV2A4
Drain Pump - Drain Pump -
Refrigerant Leakage Detector - Cassette Cover -
EEV Kit PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
Independent Power Module PRGK024A0 EEV Kit -
Plasma Kit PRIP0 Independent Power Module PRIP0
Robot Cleaner - Robot Cleaner -
Pre Filter (washable) ○ Pre Filter (washable) ○
Ion Generator - Ion Generator -
CO2 Sensor - CO2 Sensor -
Ventilation Kit - Ventilation Kit -
IR Receiver - IR Receiver -
Zone Controller - Zone Controller -
PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible), PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible),
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus) PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus)
External Input (1 point) ○ External Input (1 point) ○
Wi-Fi PWFMDD200 1) Wi-Fi PWFMDD200

※ ○ : Applied, - : Not Applied ※ ○ : Applied, - : Not Applied


Option: Refer to model name in table Option: Refer to model name in table
1) Available from April 2020 1) Available from April 2020

152 / 153
INDOOR _ CONSOLE & FLOOR STANDING UNIT INDOOR _ CONSOLE & FLOOR STANDING UNIT _ KEY FEATURES

SMART COMFORT(FLOOR STANDING UNIT)


Wi-Fi Control Protect Cold Draft
CONSOLE & Access your air conditioner anytime and from anywhere. The floor standing unit protects cold draft coming from
window and preventing condensation.

FLOOR STANDING UNIT


LG ThinQ
Without Floor Standing
Search “LG ThinQ” on Google market or Appstore then

INDOOR
UNITS
LG ThinQ download the app.

Wi-Fi

CONSOLE & FLOOR STANDING UNIT


LG ThinQ
Cold Draft

With Floor Standing

Block cold draft and


supply heating

COMFORT(CONSOLE)
Air Flow Direction Change
During the cooling operation, the vane adjusts upwards to direct the
air flow towards the ceiling. When heating, the vane directs the warm
air downwards to balance the room temperature especially for floor. 3 Way Flexible Piping
Cooling Heating (Normal) Heating (Option) It is possible to install and connect the outdoor unit in 3
different ways (Side, Back, Floor).

Back

Cold Draft Protection


The console protects cold draft from windows to provide
comfortable environment. Side

Without Console With Console Floor

Features & Benefits Key Applications


Sliding Type Filter
• 6 way flexible piping • Residential building Easy maintenance and extended product life with sliding type filter.
• Cold draft window protection • Hotel 5-Step Vane Control
• Condensation protection • Historical building There are 5 different stages to control air flow direction.
Step3 Step4
Step2

Step5
Floor standing Console Floor Standing Unit
Smart Wi-Fi ○ ○ Step1
Energy Efficiency Jet Cool - ○
Sliding type
Health Lonizer ○ - Easy cleaning
Fast Cooling & Heating Jet Cool
Sleep Mode


-

6 Way Flexible Piping
It is possible to install and connect the outdoor unit in 6 different ways.
Timer (on / off) ○ ○
(Right Side, Right Back, Right Floor, Left Side, Left Back, Left Floor)
Comfort Timer (weekly) ○ ○
Two Thermistor Control ○ ○
Group Control ○ ○
※ ○ : Applied, - : Not applied

154 / 155
INDOOR _ CONSOLE & FLOOR STANDING UNIT _ SPECIFICATION

CONSOLE CONSOLE
ARNU07GQAA4 / ARNU09GQAA4 ARNU12GQAA4 / ARNU15GQAA4

INDOOR
UNITS
CONSOLE & FLOOR STANDING UNIT
Model Unit ARNU07GQAA4 ARNU09GQAA4 Model Unit ARNU12GQAA4 ARNU15GQAA4
Cooling Capacity kW 2.2 2.8 Cooling Capacity kW 3.6 4.5
Heating Capacity kW 2.5 3.2 Heating Capacity kW 4.0 5.0
Power Input Power Input
Nominal W 15 / 12 / 10 15 / 12 / 10 Nominal W 18 / 15 / 13 24 / 19 / 17
(H / M / L) (H / M / L)
Exterior Color Morning Fog Morning Fog Exterior Color Morning Fog Morning Fog
RAL Code RAL 9001 RAL 9001 RAL Code RAL 9001 RAL 9001
Dimensions Body mm 700 x 600 x 210 700 x 600 x 210 Dimensions Body mm 700 x 600 x 210 700 x 600 x 210
(W x H x D) Shipping mm 775 x 662 x 284 775 x 662 x 284 (W x H x D) Shipping mm 775 x 662 x 284 775 x 662 x 284
Type Turbo fan Turbo fan Type Turbo fan Turbo fan
Motor Output x Number W x No. 48 x 1 48 x 1 Motor Output x Number W x No. 48 x 1 48 x 1
Fan Fan
Air Flow Rate (H / M / L) m³/min 6.7 / 5.9 / 4.8 6.7 / 5.9 / 4.8 Air Flow Rate (H / M / L) m³/min 7.5 / 5.9 / 4.8 8.7 / 6.7 / 5.9
Motor Type BLDC BLDC Motor Type BLDC BLDC
Air Filter Pre Filter Pre Filter Air Filter Pre Filter Pre Filter
Liquid Side mm (inch) Ø6.35 (1/4) Ø6.35 (1/4) Liquid Side mm (inch) Ø6.35 (1/4) Ø6.35 (1/4)
Pipe Pipe
Gas Side mm (inch) Ø12.7 (1/2) Ø12.7 (1/2) Gas Side mm (inch) Ø12.7 (1/2) Ø12.7 (1/2)
Connections Connections
Drain Pipe (Internal Dia.) mm (inch) Ø12 (15/32) Ø12 (15/32) Drain Pipe (Internal Dia.) mm (inch) Ø12 (15/32) Ø12 (15/32)
Weight Body kg 14.0 14.0 Weight Body kg 14.0 14.0
Sound Pressure Levels (H / M / L) dB(A) 37 / 34 / 28 37 / 34 / 28 Sound Pressure Levels (H / M / L) dB(A) 39 / 34 / 28 42 / 37 / 31
Sound Power Levels (H / M / L) dB(A) 53 / 50 / 44 53 / 50 / 44 Sound Power Levels (H / M / L) dB(A) 56 / 50 / 44 58 / 53 / 50
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50
Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C

Note : 1. Performance tested under EN14511 Note : 1. Performance tested under EN14511
2. Capacities are based on the following conditions 2. Capacities are based on the following conditions
- Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero - Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero
3. Due to our policy of innovation, some specifications may be changed without notification 3. Due to our policy of innovation, some specifications may be changed without notification

Accessories Accessories
Chassis ARNU07GQAA4 ARNU15GQAA4 Chassis ARNU12GQAA4 ARNU15GQAA4
Drain Pump - Drain Pump -
Cassette Cover - Cassette Cover -
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
EEV Kit PRGK024A0 EEV Kit PRGK024A0
Independent Power Module PRIP0 Independent Power Module PRIP0
Robot Cleaner - Robot Cleaner -
Pre Filter (washable) ○ Pre Filter (washable) ○
Ion Generator ○ Ion Generator ○
CO2 Sensor - CO2 Sensor -
Ventilation Kit - Ventilation Kit -
IR Receiver - IR Receiver -
Zone Controller - Zone Controller -
PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible), PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible),
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus) PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus)
External Input (1 point) ○ External Input (1 point) ○
Wi-Fi PWFMDD200 Wi-Fi PWFMDD200

※ ○ : Applied, - : Not Applied ※ ○ : Applied, - : Not Applied


Option: Refer to model name in table Option: Refer to model name in table
1) Available from April 2020 1) Available from April 2020

156 / 157
INDOOR _ CONSOLE & FLOOR STANDING UNIT _ SPECIFICATION

FLOOR STANDING UNIT FLOOR STANDING UNIT


ARNU07GCEA4 / ARNU09GCEA4 ARNU07GCEU4 / ARNU09GCEU4
ARNU12GCEA4 / ARNU15GCEA4 ARNU12GCEU4 / ARNU15GCEU4
ARNU18GCFA4 / ARNU24GCFA4 ARNU18GCFU4 / ARNU24GCFU4

INDOOR
UNITS
* A : Floor Standing with case * U : Floor Standing without case

CONSOLE & FLOOR STANDING UNIT


Model Unit ARNU07GCEA4 ARNU09GCEA4 ARNU12GCEA4 ARNU15GCEA4 ARNU18GCFA4 ARNU24GCFA4 Model Unit ARNU07GCEU4 ARNU09GCEU4 ARNU12GCEU4 ARNU15GCEU4 ARNU18GCFU4 ARNU24GCFU4
Cooling Capacity kW 2.2 2.8 3.6 4.5 5.6 7.1 Cooling Capacity kW 2.2 2.8 3.6 4.5 5.6 7.1
Heating Capacity kW 2.5 3.2 4.0 5.0 6.3 8.0 Heating Capacity kW 2.5 3.2 4.0 5.0 6.3 8.0
Power Input Power Input
Nominal W 24 / 17 / 14 30 / 24 / 17 36 / 30 / 24 44 / 35 / 28 54 / 41 / 29 84 / 54 / 41 Nominal W 24 / 17 / 14 30 / 24 / 17 36 / 30 / 24 44 / 35 / 28 54 / 41 / 29 84 / 54 / 41
(H / M / L) (H / M / L)
Exterior Color Morning Fog Morning Fog Morning Fog Morning Fog Morning Fog Morning Fog Dimensions Body mm 978 x 639 x 190 978 x 639 x 190 978 x 639 x 190 978 x 639 x 190 1,256 x 639 x 190 1,256 x 639 x 190
RAL Code RAL 9001 RAL 9001 RAL 9001 RAL 9001 RAL 9001 RAL 9001 (W x H x D) Shipping mm 1,055 x 702 x 260 1,055 x 702 x 260 1,055 x 702 x 260 1,055 x 702 x 260 1,333 x 702 x 260 1,333 x 702 x 260
Dimensions Body mm 1,067 x 635 x 203 1,067 x 635 x 203 1,067 x 635 x 203 1,067 x 635 x 203 1,345 x 635 x 203 1,345 x 635 x 203 Type Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan
(W x H x D) Shipping mm 1,154 x 705 x 289 1,154 x 705 x 289 1,154 x 705 x 289 1,154 x 705 x 289 1,432 x 705 x 289 1,432 x 705 x 289 Motor Output x Number W x No. 19 x 1, 5 x 1 19 x 1, 5 x 1 19 x 1, 5 x 1 19 x 1, 5 x 1 19 x 2 19 x 2
Fan
Type Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan Air Flow Rate (H / M / L) m³/min 8.5 / 7.5 / 6.5 9.5 / 8.5 / 7.5 10.5 / 9.5 / 8.5 11.5 / 10.0 / 9.5 16.0 / 14.0 / 12.0 18.0 / 16.0 / 14.0
Motor Output x Number W x No. 19 x 1, 5 x 1 19 x 1, 5 x 1 19 x 1, 5 x 1 19 x 1, 5 x 1 19 x 2 19 x 2 Motor Type BLDC BLDC BLDC BLDC BLDC BLDC
Fan
Air Flow Rate (H / M / L) m³/min 8.5 / 7.5 / 6.5 9.5 / 8.5 / 7.5 10.5 / 9.5 / 8.5 11.5 / 10.0 / 9.5 16.0 / 14.0 / 12.0 18.0 / 16.0 / 14.0 Air Filter Pre Filter Pre Filter Pre Filter Pre Filter Pre Filter Pre Filter
Motor Type BLDC BLDC BLDC BLDC BLDC BLDC Liquid Side mm (inch) Ø6.35 (1/4) Ø6.35 (1/4) Ø6.35 (1/4) Ø6.35 (1/4) Ø6.35 (1/4) Ø9.52 (3/8)
Pipe
Air Filter Pre Filter Pre Filter Pre Filter Pre Filter Pre Filter Pre Filter Gas Side mm (inch) Ø12.7 (1/2) Ø12.7 (1/2) Ø12.7 (1/2) Ø12.7 (1/2) Ø12.7 (1/2) Ø15.88 (5/8)
Connections
Liquid Side mm (inch) Ø6.35 (1/4) Ø6.35 (1/4) Ø6.35 (1/4) Ø6.35 (1/4) Ø6.35 (1/4) Ø9.52 (3/8) Drain Pipe (Internal Dia.) mm (inch) Ø12 (15/32) Ø12 (15/32) Ø12 (15/32) Ø12 (15/32) Ø12 (15/32) Ø12 (15/32)
Pipe
Gas Side mm (inch) Ø12.7 (1/2) Ø12.7 (1/2) Ø12.7 (1/2) Ø12.7 (1/2) Ø12.7 (1/2) Ø15.88 (5/8) Weight Body kg 20.0 20.0 20.0 20.0 26.0 26.0
Connections
Drain Pipe (Internal Dia.) mm (inch) Ø12 (15/32) Ø12 (15/32) Ø12 (15/32) Ø12 (15/32) Ø12 (15/32) Ø12 (15/32) Sound Pressure Levels (H / M / L) dB(A) 35 / 33 / 31 36 / 34 / 32 37 / 35 / 33 38 / 37 / 35 40 / 37 / 34 43 / 40 / 37
Weight Body kg 27.0 27.0 27.0 27.0 34.0 34.0 Sound Power Levels (H / M / L) dB(A) 52 / 47 / 43 54 / 51 / 47 54 / 51 / 50 55 / 54 / 51 57 / 54 / 50 61 / 57 / 54
Sound Pressure Levels (H / M / L) dB(A) 35 / 33 / 31 36 / 34 / 32 37 / 35 / 33 38 / 37 / 35 40 / 37 / 34 43 / 40 / 37 Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
Sound Power Levels (H / M / L) dB(A) 52 / 47 / 43 54 / 51 / 47 54 / 51 / 50 55 / 54 / 51 57 / 54 / 50 61 / 57 / 54 Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
Note : 1. Performance tested under EN14511
Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C 2. Capacities are based on the following conditions
- Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
Note : 1. Performance tested under EN14511 - Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero
2. Capacities are based on the following conditions 3. Due to our policy of innovation, some specifications may be changed without notification
- Cooling : Indoor temp. 27℃ (80.6℉) DB / 19℃ (66.2℉) WB, Outdoor temp. 35℃ (95℉) DB / 24℃ (75.2℉) WB, Interconnecting piping length 7.5m, Level difference of zero
- Heating : Indoor temp. 20℃ (68℉) DB / 15℃ (59℉) WB, Outdoor temp. 7℃ (44.6℉) DB / 6℃ (42.8℉) WB, Interconnecting piping length 7.5m, Level difference of zero
3. Due to our policy of innovation, some specifications may be changed without notification

Accessories Accessories
Chassis ARNU07GCEA4 ARNU09GCEA4 ARNU12GCEA4 ARNU15GCEA4 ARNU18GCFA4 ARNU24GCFA4 Chassis ARNU07GCEU4 ARNU09GCEU4 ARNU12GCEU4 ARNU15GCEU4 ARNU18GCFU4 ARNU24GCFU4
Drain Pump - - Drain Pump - -
Cassette Cover - - Cassette Cover - -
Refrigerant Leakage Detector PRLDNVS0 PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0 PRLDNVS0
EEV Kit PRGK024A0 - EEV Kit PRGK024A0 -
Independent Power Module PRIP0 PRIP0 Independent Power Module PRIP0 PRIP0
Robot Cleaner - - Robot Cleaner - -
Pre Filter (washable) ○ ○ Pre Filter (washable) ○ ○
Ion Generator - - Ion Generator - -
CO2 Sensor - - CO2 Sensor - -
Ventilation Kit - - Ventilation Kit - -
IR Receiver PWLRVN000 PWLRVN000 IR Receiver PWLRVN000 PWLRVN000
Zone Controller - - Zone Controller - -
PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible), PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible),
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus) PDRYCB320 (Universal input1)), PDRYCB400 (2 points input), PDRYCB500 (Modbus)
External Input (1 point) ○ ○ External Input (1 point) ○ ○
Wi-Fi PWFMDD200 PWFMDD200 Wi-Fi PWFMDD200 PWFMDD200

※ ○ : Applied, - : Not Applied ※ ○ : Applied, - : Not Applied


Option: Refer to model name in table Option: Refer to model name in table
1) Available from April 2020 1) Available from April 2020

158 / 159
INDOOR _ CONSOLE & FLOOR STANDING UNIT _ COMPATIBILITY

COMPATIBILITY

INDOOR
Wired Remote Controller

UNITS
Required Controller Centralized Controller
New
Premium Simple
Function Name Standard III Standard II
No. Function Description Wired Remarks (PREMTA000 Simple for Hotel Simple
(4th generation Centralized (PREMTB100) (PREMTBB01)
Remote AC EZ AC EZ Touch AC Smart 5 ACP 5 AC Manager 5
indoor) Controller PREMTA000A (PQRCHCA0Q / (PQRCVCL0Q /
Controller (PREMTBB10) (PREMTB001) (PQCSZ250S0) (PACEZA000) (PACS5A000) (PACP5A000) (PACM5A000)
PREMTA000B) QW) QW)

Monitoring accumulated power consumption * Neccesary to install the PDI (Power Distribution Indicator) and central controller
by Wired Remote Controller
○ ○ * Combined with MULTI V WATER S outdoor unit, this function is not available. ○ ○ ○ - - - ○ ○ ○ ○
Energy Monitoring

COMPATIBILITY
1 (Accumulated Electric
Energy Check) Monitoring accumulated power consumption * Neccesary to install the PDI (Power Distribution Indicator)
by Central Control Device / PDI
- ○ * To make a report, central controller must be installed - - - - - - ○ ○ ○ ○

1) 2 set point control by Indoor and Central controller


* Wired remote controller and central controller must be installed
2 2 Set Point 2) Synchronization function with remote control ○ ○ * Combined with MULTI V WATER S outdoor unit, this function is not available.
○ ○ - - - - ○ ○ ○ ○
(Synchronization Setting and Monitoring)

* Centralized control is able to when you combine only 4th generation indoor
1) Synchronization according to occupied/unoccupied
units (Use together with 2nd generation and 4th generation indoors,
Occupied / Unoccupied by Indoor and Central control
only wired remote controller is able to set this function as existing way) ○ ○ - - - - ○ ○ ○ ○
3 Scheduling Function ○ ○ * Wired remote controller or central controller must be installed
(Sub Func. Enable) 2) Synchronization icon with remote controller
(Function can be activeated using just one control device.)
(Synchronization Monitoring)
* Combined with MULTI V WATER S outdoor unit, this function is not available.

4 Group Control Group Control can use Additional function ○ ○


* Check more details in PDB (Product Data Book) ○ ○ ○ - - - - ○ ○ ○
* Central controller can create and control group.

Test run mode can be operated in cooling mode and ○ ○ ○ - - - - - - -


5 Test Run (Heating)
heating mode for easy service
○ -

Model Information Product Type / Indoor Type / Indoor capacity ○ ○ ○ - - - - - - -


6
Monitoring information can be monitored by remote controller
○ -

Indoor unit address ○ ○ ○ - - - - - - -


7
checking
Wired remote controller can check indoor unit address information ○ -

* Central controller has been installed, CH230 error code can be recognized
(Old/New Same)
Refrigerant Leakage ○ ○ ○ - - - - ○ ○ -
8
Detection
Function error sign display when refrigerant leakage occurred ○ ○ * Without Central Controller, it is able to recognize with wired remote controller (CH230)
* Combined with MULTI V WATER S outdoor unit, this function is not available.
* Accessory PRLDNVS0 must be separately ordered

Thermo On / Off range User can set cooling thermo on/off range with wired remote ○ ○ ○ - - - - - - -
9
Setting (Cooling) controller for prevention overcooling
○ - * Thermo On / Off temperature setting (3 step)

Thermo On / Off range User can set heating thermo on/off range with wired remote ○ (4 step) ○ (4 step) ○ (3 step) ○ (3 step) ○ (3 step) - - - - -
10
Setting (Heating) controller for prevention overheating. (4 Steps)
○ - * Thermo On / Off temperature setting (4 step)

Static Pressure
Depends on the installation environment, 4th generation Ceiling
11 Step Control
11 Concealed Duct can control the static pressure by 11 steps for ○ - * Only applied in Ceiling Concealed Duct ○ ○ ○ ○ ○ - - - - -
(Only for Ceiling
providing comfortable environment
Concealed Duct Type)

* Simple On/Off control by Dry Contact at Indoor

[Example of Contact port by product type]


1 point External Input Indoor unit can be controlled by external devices without purchasing
12 ○ - * 2 Way Cassette : CN-CC Port - ○ ○ - - - - - - -
(On / Off control) Dry contact as an accessory (All 4th generation indoors)
(Wired remote controller installation function mode 41 is required)
* 1 Way / 4 Way Cassette / Ceiling Concealed Duct / Wall Mounted Unit
Console / FAU / Floor Standing (with case / without case) : CN-EXT Port

Filter Sign The alarm activates when the filter needs to be cleaned, * The alarm activates on the central controller, but the remaining time is
13 ○ ○ ○ ○ ○ - - ○ ○ ○ ○ ○
(Remaining Time) and the time remaining for cleaning is displayed on the screen. not displayed.

Auto restart function After the power failure compensation, stand by at OFF mode
14 ○ - ○ ○ ○ - - - - - - -
Disable / Enable Restore the operation for the status before the power off

15 Indoor Humidity display Monitoring indoor humidity Wired Remote Controller ○ ○ * Available only with MULTI V 5 - ○ - - - - - ○ ○ -

16 Comfort Cooling setting set the outdoor unit Comfort cooling operation value ○ ○ * Available only with MULTI V 5 - ○ - - - - - ○ ○ -

17 Smart Load Control setting Change the outdoor unit’s Smart Load Control stage value. ○ ○ * Available only with MULTI V 5 - ○ - - - - - ○ ○ -

ODU Refrigerant Noise


18
Reduction setting
set the outdoor unit’s refrigerant noise reduction function ○ ○ * Available only with MULTI V 5 - ○ - - - - - ○ ○ -

Low noise mode time


19
setting
set the start and end time of the outdoor unit’s low noise mode operation ○ ○ * Available only with MULTI V 5 - ○ - - - - ○ ○ ○ -

Note : 1) No.1, 2, 3, 8 : Functions are available to use together with 4th generation Indoor units only. If used together 2nd generation indoor unit and ※ ○ : Applied, - : Not applied
4th generation indoor unit functions will not be activate. Combined with MULTI V Water S outdoor unit this function is not available
2) No. 4, 5, 6, 7, 9, 10, 11, 12, 13, 14 : If used together 2nd generation indoor unit and 4th generation indoor unit these functions will be activate only in 4th generation indoor
3) 2nd generation indoor unit : Ceiling & Floor Convertible Unit, Ceiling Suspended Unit, HYDRO KIT (Low Temp. / High Temp.), ERV DX (with Humidifier, without Humidifier),
AHU Communication Kit

160 / 161
INDOOR _ CONSOLE & FLOOR STANDING UNIT _ COMPATIBILITY INDOOR _ CONSOLE & FLOOR STANDING UNIT _ FEATURE FUNCTIONS

COMPATIBILITY FEATURE FUNCTIONS

INDOOR
Premium Standard llI Standard ll Simple Simple for Hotel Wireless Dry Contact

UNITS
Wired Remote Controller Wireless
Controller Name Wi-fi
Remote Controller
Controller Premium Standard III Standard II Simple Simple(Hotel) Controller

Dry Contact for


Thermostat
Product PREMTA000
PREMTA000A PREMTBB10 PREMTB100 PREMTBB01 PREMTB001 PQRCVCLOQ PQRCVC0QW PQRCHCA0Q
PQRCH-
NEW Simple Dry 2 points Dry
Contact Contact PDRYCB300 For Modbus
CA0QW PWLSSB21H PDRYCB500
PREMTA000B (H/P) PDRYCB000 PDRYCB400 NEW
PDRYCB320*

COMPATIBILITY / FEATURE FUNTIONS


Model Name
ARNU-A4
ARNU-B4
○ ○ ○ ○ ○ ○ ○ ○ ○ ○
4 Way PREMTA000
PREMTB100 PREMTB001 PQRCVCL0Q PQRCHCA0Q NEW
PREMTA000A PWFMDD200
PREMTBB10 PREMTBB01 PQRCVCL0QW PQRCHCA0QW PWLSSB21H (H/P)
Ceiling PREMTA000B
ARNU-B4
Mounted
ARNU-C4
○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Cassette On / Off ○ ○ ○ ○ ○ ○ ○
2 Way / 1 Way

Fan Speed Control ○ ○ ○ ○ ○ ○ ○


ARNU-A4 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Temperature Setting ○ ○ ○ ○ ○ ○ ○
Round CST

Mode Change ○ ○ ○ ○ - ○ ○
ARNU-A4 ○ ○ ○ ○ ○ △ ○ ○ ○ ○
Auto Swing ○ ○ ○ ○ ○ ○
High Sensible

Vane Control
Ceiling Basic ○ ○ ○ ○ ○ ○ ○
(Louver Angle)
Concealed ARNU-A4 ○ ○ ○ ○ ○ △ ○ ○ ○ ○
Duct
High / Mid Statics E.S.P
○ ○ ○ ○ ○ - -
(External Static Pressure)

ARNU-G4 ○ ○ ○ ○ ○ △ ○ ○ ○ ○ Electric Failure


○ ○ ○ ○ ○ - ○
Low Statics Compensation

FAU Indoor Temperature Display ○ ○ ○ ○ ○ ○


(Fresh Air ARNU-Z4 ○ ○ ○ ○ ○ △ ○ ○ ○ ○
intake Unit) ALL Button Lock
○ ○ ○ ○ ○ - -
(Child Lock)
Convertible
& Ceiling Schedule / Timer Weekly~Yearly Weekly~Yearly Weekly - - Sleep / On / Off Weekly
Suspended
ARNU-A4 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Unit Additional Mode Setting 1)
○ ○ ○ - - - -
MULTI V

Time Display ○ ○ ○ - - ○ -
Console ARNU-A4 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Humid. Display ○ ○ - - - - -
Floor ARNU-A4 Advanced Lock
Standing ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ (mode, set point, set point Advanced Lock Advanced Lock - - - - -
Unit ARNU-U4 range, on/off Lock)
Advanced
Filter Sign ○ ○ ○ - - - -
ARNU-A4 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Energy Management 2) ○ ○ ○ - - - -

Wall Dual Set Point ○ ○ - - - - -


Mounted ARNU-R4 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Unit Human Detection - ○ - - - - -

ARNU-A4 Temp, Humidity


○ ○ - - - - -
ARNU-C4 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Compensation
ARNU-N4
Wifi AP mode setting ○ ○ ○ ○ ○ ○ -

HYDRO Operation Status LED ○ ○ ○ ○ ○ - -


KIT 1)
ARNH-A4 - - - - - - ○ - ○ -
Wireless Remote Controller
○3) - ○3) ○3) ○3) - -
Energy Receiver
Recovery
Ventilator ○ ○ ○ - - - ○ - - ○ ETC Display 5 inch Color 4.3 inch Color 4.3 inch mono 2.6 inch mono 2.6 inch mono 2 inch mono -
Ventilation
Energy Recovery Size (W x H x D, mm) 137 x 121 x 16.5 120 x 120 x 16 120 x 120 x 16 64 x 120 x 15 64 x 120 x 15 51 x 153 x 26 -
Ventilator with
DX coil
○ ○ ○ - - - ○ - - ○ Black Light Control for
○ ○ - - - - -
Screen Saver

※ ○ : Compatible, △ : Need wired remote controller / IR receiver, - : Not compatible ※ ○ : Applied, - : Not Applied
* Available from April 2020
AHU Communication Kit ○ ○ ○ - - △ - - - - 1) It might not be indicated or operated at the partial product
1) It has a separate remote controller 2) Centralized control (PACEZA000 / PACS5A000 / PACP5A000 / PLNWKB000) and PDI (PQNUD1S40 / PPWRDB000) should be installed for this function
3) For ceiling type duct
Note.
- Indoor unit should have functions requested by the controller
- If you need more detail, please refer to the manual of product. (http://partner.lge.com: Home> Doc.Library> Manual)

162 / 163
HOT WATER
SOLUTION

HOT WATER
SOLUTION
HYDRO KIT

164 / 165
INDOOR _ HYDRO KIT INDOOR _ HYDRO KIT _ KEY FEATURES

HYDRO KIT EFFICIENCY


Features & Benefits Key Applications Cost Savings with High Efficiency High Temperature HYDRO KIT
• Lower operation cost compared to fossil fuel-based systems such as boilers. •W
 here Hot Water is needed such as domestic Hot Water,
Equivalent installation cost of traditional boiler with reduced Cycle Diagram
operational costs.
• More energy saving through MULTI V heat recovery system. In-floor or radiant heat. Where cold water is needed such as Outdoor Unit High Temperature HYDRO KIT Heating
1st Proposal MULTI V 5 HYDRO KIT by Hot Water
Refrigerant - Refrigerant -
Fan coil unit and chilled beam. (Air Conditioning + Hot Water Supply + Floor Heating)
Air-Refrigerant Refrigerant Water
2nd Proposal MULTI V 5 Air-Conditioning + Gas Boiler
(Hot Water Supply + Floor Heating)
3rd Proposal MULTI V 5 Air-Conditioning + Oil Boiler AIR
50°C 80°C
(Hot Water Supply + Floor Heating)
Analysis Conditions
- Building Type : Dormitory, Flats
- Cooling / Floor Heating / Sanitary Hot Water for 10 years High Temperature Technology

HOT WATER
SOLUTION
- Cooling : MULTI V IV Indoor Unit

Pressure
Water
- Floor Heating : Medium Temp. HYDRO KIT (1ea)
- Sanitary Hot Water : High Temp. HYDRO KIT (2ea), Sanitary Hot Water Tanks
- Electricity Cost : Average Cost in EU R410A
- Gas Cost : Average Cost in EU
R134A
- Oil Cost : Average Cost in EU Stage 1
Hot Water Heating Cooling
Stage 2
Air
Initial Costs Annual Operating Costs

HYDRO KIT
Enthalpy

25,000 100% 90% 95% 25,000 229%


Radiant Heating / Cooling Fan Coil Unit Heating / Cooling Hot water / Cold Water
20,000

15,000
20,000

15,000 171% Various Applications


Radiator 10,000 10,000 100% Applicable to a variety of facilities including hospitals,
5,000 5,000 residences and resorts that need floor heating and
FCU Gas Boiler Oil Boiler Gas Boiler Oil Boiler domestic hot water supply.
Floor heating
LCC
50,000
Oil boiler
Gas boiler
40,000

Combination 30,000

20,000 Dormitory Hotel Office Restaurant

10,000
1 2 3 4 5 6 7 8 9 10 (Year)

Thermal Storage Tank

Hot water+ Radiant heating HR unit (Cooling & Hot water) Thermal Storage System
Energy Savings through Fitness Hospital Factory Residential

Heat Recovery
Energy costs can be minimized by reusing the wasted

CONVENIENCE heat from indoor units. Hotel Application


Constant simultaneous
Conventional
Absorbed heat is released to outdoor air. cooling and heating operatin
Total Solution Eco-friendly Solution during summer to provide hot
Heat Transfer water by using wasted heat
Total solution provided with heat pump, air conditioning Green energy solution through the reduction of CO2 Heat
Released
(cooling by refrigerant and cold water/heating by refrigerant emmisions. energy from indoor cooling
pump
hot water) and domestic hot water supply. Hot water Heat
Absorption
process.
Conventional System
CO2 Emissions
Refrigerant piping Water piping Conventional Boiler Domestic
(%) Hot Water Tank
HR Unit Hot Water Supply Cooling
Indoor Unit 120

HYDRO KIT
Domestic
Hot Water Tank 100
100%
Absorbed heat from indoor space is used for making hot water. Office Application
76% Hot water can be supplied
Air Heat Transfer
Hot water conditioning 60 at all times in the office by
HYDRO KIT HR Unit
supply cooling the HR unit to
MULTI V 5 40 30%
On Average
pump
Hot water Heat
Absorption
warm up the sanitary tank,
High temperature using waste energy.
MULTI V 5 Domestic
20 Hydro Kit
(Heat Recovery) Hot Water Tank
Oil Gas Hot Water Supply Cooling
Boiler Boiler
MULTI V
Outdoor Unit Floor heating
(Water Cooled) Middle temperature

166 / 167
INDOOR _ HYDRO KIT _ SPECIFICATION

HYDRO KIT HYDRO KIT


ARNH04GK2A4 / ARNH10GK2A4 ARNH04GK3A4 / ARNH08GK3A4

HOT WATER
SOLUTION
Model Unit ARNH04GK2A4 ARNH10GK2A4 Model Unit ARNH04GK3A4 ARNH08GK3A4
Cooling Capacity kW 12.3 28.0 Heating Capacity kW 13.8 25.2
Heating Capacity kW 13.8 31.5 Power Input Nominal W 2,300 5,000
Power Input Nominal W 10 10 Exterior Color Morning Gray Morning Gray
Exterior Color Morning Gray Morning Gray RAL Code RAL 7030 RAL 7030
RAL Code RAL 7030 RAL 7030 Dimensions Body mm 520 x 1,080 x 330 520 x 1,080 x 330
Dimensions Body mm 520 x 631 x 330 520 x 631 x 330 (W x H x D) Shipping mm 682 x 1,168 x 423 682 x 1,168 x 423

HYDRO KIT
(W x H x D) Shipping mm 677 x 687 x 418 677 x 687 x 418 Liquid Side mm (inch) Ø9.52 (3/8) Ø9.52 (3/8)
Pipe
Liquid Side mm (inch) Ø9.52 (3/8) Ø9.52 (3/8) Gas Side mm (inch) Ø15.88 (5/8) Ø19.05 (3/4)
Pipe Connections
Gas Side mm (inch) Ø15.88 (5/8) Ø22.2 (7/8) Drain Pipe (Internal Dia.) A (inch) 25A (Male PT 1) 25A (Male PT 1)
Connections
Drain Pipe (Internal Dia.) A (inch) 25A (Male PT 1) 25A (Male PT 1) Water Pipe Inlet A (inch) 25A (Male PT 1) 25A (Male PT 1)
Water Pipe Inlet A (inch) 25A (Male PT 1) 25A (Male PT 1) Connections Outlet A (inch) 25A (Male PT 1) 25A (Male PT 1)
Connections Outlet A (inch) 25A (Male PT 1) 25A (Male PT 1) Weight Body kg 87.0 91.0
Weight Body kg 29.2 33.7 Sound Pressure Levels (H / M / L) dB(A) 43 46
Sound Pressure Levels (H / M / L) dB(A) 26 26 Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
Communication Cable mm2 x No. 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
1) Nominal : Performance tested under EN14511
Note : 1. Capacities are based on the following conditions :
1) Nominal : Performance tested under EN14511
- Heating : Indoor 20°C (68°F) DB / 15°C (59°F) WB, Outdoor 7°C (44.6°F) DB / 6°C (42.8°F) WB, Water Inlet 55°C (131°F) / Outlet 65°C (149°F)
Note : 1. Capacities are based on the following conditions :
2. Piping Length : Interconnected Pipe Length = 7.5m
- Cooling : Indoor 27°C (80.6°F) DB / 19° C (66.2°F) WB, Outdoor 35°C (95°F) DB / 24°C (75.2°F) WB, Water Inlet 23°C (73.4°F) / Outlet 18°C (64.4°F)
3. Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero.
- Heating : Indoor 20°C (68°F) DB / 15°C (59°F) WB, Outdoor 7°C (44.6°F) DB / 6°C (42.8°F) WB, Water Inlet 30°C (86°F) / Outlet 35°C (95°F)
4. MULTI V S 4HP (ARUN040GSS0, ARUN040LSS0) cannot be connected to Hydro Kit.
2. Piping Length : Interconnected Pipe Length = 7.5m
5. MULTI V Water S cannot be connected to Hydro Kit.
3. Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero.
4. MULTI V S 4HP (ARUN040GSS0, ARUN040LSS0) cannot be connected to Hydro Kit.
5. MULTI V Water S cannot be connected to Hydro Kit.
6. Anti freezing liquid should be added under 10°C (outdoor temp.) during cooling mode.

Accessories Accessories
Chassis ARNH04GK2A4 ARNH10GK2A4 Chassis ARNH04GK3A4 ARNH08GK3A4
Drain Pump - Drain Pump -
Cassette Cover - Cassette Cover -
Refrigerant Leakage Detector PRLDNVS0 Refrigerant Leakage Detector PRLDNVS0
EEV Kit - EEV Kit -
Independent Power Module ○ Independent Power Module ○
Robot Cleaner - Robot Cleaner -
Pre Filter (washable) - Pre Filter (washable) -
Ion Generator - Ion Generator -
CO2 Sensor - CO2 Sensor -
Ventilation Kit - Ventilation Kit -
IR Receiver - IR Receiver -
Zone Controller -
Zone Controller -
PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible)
PDRYCB000 (1 point contact), PDRYCB300 (8 points for thermostat compatible) Dry Contact (with additional accessory)
Dry Contact (with additional accessory) PDRYCB320 (Universal input1))
PDRYCB320 (Universal input1))
External Input (1 point) ○
External Input (1 point) ○
Wi-Fi PWFMDD200
Wi-Fi PWFMDD200
※ ○ : Applied, - : Not applied
※ ○ : Applied, - : Not applied Option : Refer to model name in table
Option : Refer to model name in table 1) Available from April 2020
1) Available from April 2020

168 / 169
VENTILATION
SOLUTIONS

VENTILATION
SOLUTIONS
ERV / ERV WITH DX COIL

170 / 171
INDOOR _ VENTILATION SOLUTIONS INDOOR _ VENTILATION SOLUTIONS _ KEY FEATURES

HIGH EFFICIENCY
High Efficiency Heat Exchanger CO2 Auto Operation
ENERGY RECOVERY Efficiency and comfort is ensured through the high-efficiency
energy recovery central core which recovers energy from
LG ERV reduces energy loss with auto fan speed control
following CO2 level

VENTILATION (ERV)
Fine CO2 level
the indoor air and transfers it to the fresh incoming air High occupancy Low occupancy CO2 level
without mixing the air stream. (high CO2 level) (low CO2 level) Fan speed

- Reduce power consumption


for ventilation
- Reduce cooling, heating
energy loss by ventilation

Air Filter
Low
Exchanger Air
Supply Air
4% Energy Saving
(Annually)

Extra high
Outdoor Air Indoor Air high

9 o’clock 10 11 12 13 14 15 16 17
* This function is operated with ‘Night Time Free Cooling’ on remote controller. (with MULTI V only)
** Energy saving ratio can be differed by weather condition.
※ Test Condition - Office (49,000ft2) / Occupancy : 30 / Area : London, UK
- ERV (1000 CMH) + MULTI V 4 (12HP) Unit Combination

VENTILATION
- Other conditions are subject to BREEAM.

SOLUTIONS
Exhaust System Seasonal Auto Operation
The exhaust system uses a high static sirocco fan to LG ERV senses outdoor temperature and operates
effectively remove contaminants from indoor air. Supply automatically following weather condition.
and exhaust air flows are completely separated in the heat High temp. Natural ventilation

ERV
Heat recovery LG ERV heat recovery mode
exchanger, allowing the LG ERV to filter out impurities mode LG ERV bypass mode
before supplying outdoor air to ensure indoor air is fresh
Proper temp.
and healthy. Bypass mode 5% Energy Saving
(Annually)
Exchanger Air Supply Air
Exchanger Damper
Low temp.
Air Heat recovery
Return
Air mode

Supply Month Jan. Feb. Mar. Apr. May. Jun. Jul. Aug. Sep. Oct. Nov. Dec.
Air
Heat recovery mode Bypass mode
Outdoor
Outdoor Air Indoor Air Air
Indoor Outdoor Indoor Outdoor

Outdoors Indoors Total Heat Exchanger Automatic


Change
Damper Damper
Heat Exchanger Heat Exchanger
* This function is operated with ‘Auto’ mode by wired remote control.
** Energy saving ratio can be differed by weather condition.
※ Test Condition: - Office (49,000ft2) / Occupancy : 30 / Area : London, UK
Night Time Free Cooling - ERV (1,000 CMH) + MULTI V 4 (12HP) Unit Combination
- Other conditions are subject to BREEAM.
During summer nights, indoor heat can be discharged

NECESSITY OF ERV outdoors and cool outdoor air can be brought indoors for
energy savings.
Delay Operation
Afternoon Night Morning When the air conditioner and ERV are switched on simultaneously,
Indoor lemp Outdoor lemp delay operation can reduce unnecessary heating and cooling
Energy Recovery Ventilation (ERV) (winter)
22℃ -5℃ energy loss by slowing down automatic ERV operation.
Operation Delay operation
Set Temp. Operation starts Operation air conditioner simultaneously. Operation starts with air conditioner

16 ℃ ERV makes inside coolier Inside Temp.


with bypass mode like Outside Temp. ON Energy consumption Fine CO2 level
natural ventilation
OFF 2%
Energy Saving
(Annually)
ON
CO2 level

Natural Ventilation

Office time
Outdoor lemp
-5℃
Indoor lemp
22℃
-5℃ Inside is getting
higher in the night
2% Energy Saving
(Annually) starts

24% Indoor temp Outdoor temp


because of business
machines.
Operation
time
Comfort air + Energy Saving 22℃ -5℃ * This function is operated with ‘Night Time Free Cooling’ on remote controller. (with MULTI V only)
Demand Cooling only Demand Cooling & Ventilation
Compare to natural ventilation ** Energy saving ratio can be differed by weather condition.
Energy Saving * This function is operated with ‘Night Time Free Cooling’ on remote controller. (with MULTI V only)
Heat exchanger collects wasted ※ Test Condition ** Energy saving ratio can be differed by weather condition.
Natural Ventilation loss - Office (49,000ft2) / Occupancy : 30 / Area : London, UK ※ Test Condition - Office (49,000ft2) / Occupancy : 30 / Area : London, UK
energy while ventilating. heat energy. - ERV (1000 CMH) + MULTI V 4 (12HP) Unit Combination - ERV (1000 CMH) + MULTI V 4 (12HP) Unit Combination
- Other conditions are subject to BREEAM. - Other conditions are subject to BREEAM.

172 / 173
INDOOR _ VENTILATION SOLUTIONS _ KEY FEATURES

COMFORT & RELIABILITY CONVENIENCE CONVENIENCE


CO2 Level Monitoring Easy Control Fast Ventilation Mode Installation Scene
CO2 sensor senses CO2 level in the room. Users can monitor Wired remote controller is easy for usage. Fast ventilation mode prevents the spread of contaminants LZ-H025GBA4 / LZ-H035GBA5 / LZ-050GBA5
CO2 level on new wired remote controller, and ERV controls under negative indoor pressure, and makes indoor air fresh
the fan speed automatically following the level. and comfortable quickly.
Ceiling
Ceiling suspension
suspension
Only Exhausting boltsbolts position
position Air return
Air return grillegrille
CO2 Level Visualization (user-supplied)
(user-supplied)

CO2 sensor senses indoor CO2 level and displays it on new wired remote controller. Convenient
• Flexible display EAEA
(Exhaust
(Exhaust
- Dual display with air conditioner. air outlet)
air outlet)
- Zoom selected directory to increase legibility.
Exhausting operation causes
negative indoor air pressure,
Ceiling Fixing Bolt and cannot fully ventilate.
Easy
• Navigation buttons, easy to use.
(M10~12) OAOA
(Fresh
(Fresh
• Easy installation setting air outlet)
air outlet)
Nut

150~250
Min.600
Visible Inspection

150~250
Min.600
Inspection
Main display Further information partpart
• Indoor CO2 level
Washer, Spring Lock Exhausting and Supplying 450(600)
450(600)
If the CO2 level is above 900ppm in CO2 level and room condition are • Alarm for filter change / Remained time to change filters Fast Ventilation Mode Simultaneously
the room, the red mark is on. displayed continuously. Washer, Plain Air supply
Air supply grillegrille
(user-supplied)
(user-supplied)
Monitoring CO2 Nut

VENTILATION
Maintenance
Maintenance space
space

SOLUTIONS
CO2 1215 ppm tal heat
tal heat Exchanger
Exchanger
Air Filter
Air Filter

comfort level Group Control Exhaust


Fan DuctDuct normal diameter
20.5° normal diameter
* The remote controller screen image may change. CO2 1 wired remote controller up to 16 ERV (including air Supply ØC(user-supplied)
ØC(user-supplied) Ceiling
Ceiling Fixing
Fixing BoltBolt
CO2 (user-supplied)
(user-supplied)
* Applicable to only Standard III, Premium remote 1215 ppm SEVERE
conditioner). It is convenient for large common space such Ceiling Fixing Bolt
Fan
controller.
(M10~12)
as lobby.
Nut
CO2 Concentration Control Several units combination
Duct

ERV
Using CO2 sensor, LG ERV controls exhaust air flow automatically 16 units group control is available with 1 remote controller. Washer, Spring Lock Air supply
Air supply grillegrille
Air return
Air return grillegrille

to keep indoor air fresh under settled CO2 concentration. Good looking interior External
Washer, Plain Static Pressure Control
EAEA
(Exhaust
(Exhaust
air outlet)
Inspection
Inspection partpart
The high static pressure fan can control the air volume depending
air outlet)
OAOA 450(600)
450(600)
Nut (Fresh
(Fresh air outlet)
air outlet)
RARASASA
on the length of the duct. It is also easy to control the pressure DuctDuct slope:
slope: MoreMore
thanthan
Obtaining
Obtaining
1/30(toward
1/30(toward
of right
of right
the wall)
the wall)
distance
distance (Return
(Return air) air)(Supply
(Supply
air) air)
CO2 Sensor (preventing penetration of rain water)
(AHCS 100H0) RS3 Remote level by using the remote controller for a more flexible duct (preventing penetration of rain water)

(Internal type : Default) Controller installation and easier testing.


Conventional New Air
Taping
Connection of Duct
CO2
(ppm) Controller & installation cost saving Volume Duct
Windows Windows Windows Windows

2,500
Closed Open Closed Open H Duct
M
L
1,000

0 ERV with CO2 H


Concentration Control M
L
Time (min)

Interlocking with Air Conditioning System


High Durability - LG ERV can be interlocked with air conditioners Taping
LG ERV durability is increased through bacteria-resistant material Taping
and controlled individually. Duct External Static Pressure (mmAq)

of heat exchanger and corrosion protection coating. It prevents 30 30


- This function can be operated when the system Heat Insulating Material
shortening product life due to corrosion and mold and supplies
high quality air to inside by minimizing the bacteria.
is connected with 1 remote controller. Easy Cleaning and Filter Change Aluminium
Filter can be conveniently changed and cleaned.
Others LG ERV
Remote
Inside ERV Inside ERV Control
Corrosion
occurrence
Corrosion
Main Body
protection coating MAX 16
+ Finish insulator
Duct to OA
Taping
ERV Unit Remove Side Panel

Duct
Heat Connection Flange
Insulating Material
Heat exchanger and filter Heat exchanger
Aluminium

Change Filter Remove Heat Exchanger


Breading mold Bacteria-resistant
Main Body

Duct to OA 174 / 175

Duct Connection Flange


INDOOR _ VENTILATION SOLUTIONS _ SPECIFICATION

ERV ERV
LZ-H025GBA4 / LZ-H035GBA5 LZ-H080GBA5 / LZ-H100GBA5
LZ-H050GBA5 LZ-H150GBA5 / LZ-H200GBA5

Model Unit LZ-H025GBA4 LZ-H035GBA5 LZ-H050GBA5 Model Unit LZ-H080GBA5 LZ-H100GBA5 LZ-H150GBA5 LZ-H200GBA5
Dimensions Dimensions
Body mm 988 x 273 x 1,014 Body mm 1,101 x 405 x 1,230 1,353 x 815 x 1,230
(W x H x D) (W x H x D)
Weight Body kg 44 Weight Body kg 63 130
Power Supply Ø, V, Hz 1, 220-240, 50 Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50
Normal Air flow m³/h 250 350 500 Normal Air flow m³/h 800 1,000 1,500 2,000
Operating Step Super-high / High / Low Operating Step Super-high / High / Low Super-high / High / Low
Current SH / H / L A 0.70 / 0.60 / 0.42 1.05 / 0.90 / 0.50 1.65 / 1.56 / 0.80 Current SH / H / L A 2.13 / 1.75 / 1.00 2.92 / 2.38 / 1.40 4.26 / 3.50 / 2.00 5.92 / 4.76 / 2.80

VENTILATION
SOLUTIONS
Power Input SH / H / L W 97 / 87 /52 150 / 125 / 60 247 / 230 / 95 Power Input SH / H / L W 328 / 266 / 144 463 / 370 / 208 660 / 530 / 290 926 / 740 / 420
Air Flow SH / H / L m³/h 250 / 250 / 150 350 / 350 / 210 500 / 500 / 320 Air Flow SH / H / L m³/h 800 / 800/ 660 1,000 / 1,000 / 800 1,500 / 1,500 / 1,200 2,000 / 2,000 / 1,600
External Static Pressure SH / H / L Pa 100 / 70 / 50 150 / 100 / 50 150 / 100 / 50 External Static Pressure SH / H / L Pa 160 / 100 / 50 160 / 100 / 50 160 / 100 / 50 160 / 100 / 50
Temperature Exchange ERV Mode Temperature Exchange
ERV Mode SH / H / L % 80 / 80 / 83 80 / 80 / 82 79 / 79 / 82 SH / H / L % 82 / 82 / 83 80 / 80 / 81 82 / 82 / 83 80 / 80 / 81
Efficiency Efficiency
Enthalpy Exchange Heating (SH / H / L) % 70 / 70 / 72 75 / 75 / 80 75 / 75 / 78 Enthalpy Exchange Heating (SH / H / L) % 73 / 73 / 76 71 / 71/ 73 73 / 73 / 76 71 / 71/ 73
Efficiency Cooling (SH / H / L) % 66 / 66 / 68 71 / 71 / 75 68 / 68 / 75 Efficiency Cooling (SH / H / L) % 66 / 66 / 70 64 / 64 / 67 66 / 66 / 70 64 / 64 / 67
Energy Label A+ to G Scale A B B Sound Pressure Level SH / H / L dB(A) 40 / 36 / 32 40 / 37 / 33 43 / 39 / 35 43 / 40 / 36
Sound Pressure Level SH / H / L dB(A) 29 / 28/ 24 35 / 32 / 26 37 / 36 / 28 Sound Power Level SH / H / L dB(A) 56 / 53 / 47 59 / 56 / 52 59 / 56 / 50 62 / 59 / 55

ERV
Sound Power Level SH / H / L dB(A) 50 53 / 50 / 42 57 / 56 / 46 Operating Step Super-high / High / Low Super-high / High / Low
Operating Step Super-high / High / Low Current SH / H / L A 2.13 / 1.75 / 1.00 2.92 / 2.38 / 1.40 4.26 / 3.50 / 2.00 5.92 / 4.76 / 2.80
Current SH / H / L A 0.70 / 0.60 / 0.42 1.05 / 0.90 / 0.50 1.65 / 1.56 / 0.80 Power Input SH / H / L W 328 / 266 / 144 463 / 370 / 208 660 / 530 / 290 926 / 740 / 420
Bypass Mode
Power Input SH / H / L W 97 / 87 /52 150 / 125 / 60 247 / 230 / 95 Air Flow SH / H / L m³/h 800 / 800/ 660 1,000 / 1,000 / 800 1,500 / 1,500 / 1,200 2,000 / 2,000 / 1,600
Bypass Mode
Air Flow SH / H / L m³/h 250 / 250 / 150 350 / 350 / 210 500 / 500 / 320 External Static Pressure SH / H / L Pa 160 / 100 / 50 160 / 100 / 50 160 / 100 / 50 160 / 100 / 50
External Static Pressure SH / H / L Pa 100 / 70 / 50 150 / 100 / 50 150 / 100 / 50 Sound Pressure Level SH / H / L dB(A) 41 / 37 / 33 41 / 38 / 34 44 / 40 / 36 44/ 41 / 37
Sound Pressure Level SH / H / L dB(A) 29 / 29/ 25 35 / 33 / 26 37 / 37 / 28 Qty EA 4 4+2
Duct Work
Qty EA 4 Size (Φ) mm Φ250 Φ250 + Φ350
Duct Work
Size (Φ) mm Φ200 Qty EA 1 2
Supply Air Fan
Qty EA 1 Type Direct-Drive Sirocco Direct-Drive Sirocco
Supply Air Fan
Type Direct-Drive Sirocco Qty EA 1 2
Exhaust Air Fan
Qty EA 1 Type Direct-Drive Sirocco Direct-Drive Sirocco
Exhaust Air Fan
Type Direct-Drive Sirocco Qty EA 2 4
Qty EA 2 Filters Type Cleanable fibrous fleeces Cleanable fibrous fleeces
Filters Type Cleanable fibrous fleeces Size (W x H x D) mm 1,148 x 6 x 245 1,148 x 6 x 245
Size (W x H x D) mm 855 x 10 x 166
Note : 1. ERV mode : Total Heat Recovery Ventilation mode
Note : 1. ERV mode : Total Heat Recovery Ventilation mode 2. * : Refer to dimensional drawings.
2. * : Refer to dimensional drawings. 3. Noise level :
3. Noise level : - The operating conditions are assumed to be standard
- The operating conditions are assumed to be standard - Sound measured at 1.5m below the center the body.
- Sound measured at 1.5m below the center the body. - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed.
- Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed. - The sound level at the air discharge port is about 8 dB(A) higher than the unit’s operating sound.
- The sound level at the air discharge port is about 8 dB(A) higher than the unit's operating sound. 4. Temperature and Enthalpy Exchange Efficiency at cooling Indoor Temperature : 26.5°C DB, 64.5% RH, Outdoor Temperature : 34.5°C DB, 75% RH
4. Temperature and Enthalpy Exchange Efficiency at cooling Indoor Temperature : 26.5°C DB, 64.5% RH, Outdoor Temperature : 34.5°C DB, 75% RH 5. Temperature and Enthalpy Exchange Efficiency at heating Indoor Temperature : 20.5°C DB, 59.5% RH, Outdoor Temperature : 5°C DB, 65% RH
5. Temperature and Enthalpy Exchange Efficiency at heating Indoor Temperature : 20.5°C DB, 59.5% RH, Outdoor Temperature : 5°C DB, 65% RH 6. Temperature Exchange efficiency is tested at heating condition.
6. Temperature Exchange efficiency is tested at heating condition.

Accessories Accessories
Chassis LZ-H025GBA4 LZ-H035GBA5 LZ-H050GBA5 Chassis LZ-H080GBA5 LZ-H100GBA5 LZ-H150GBA5 LZ-H200GBA5
Drain Pump - Drain Pump -
Cassette Cover - Cassette Cover -
Refrigerant Leakage Detector - Refrigerant Leakage Detector -
EEV Kit - EEV Kit -
Independent Power Module - Independent Power Module -
Robot Cleaner - Robot Cleaner -
Pre Filter (washable) - Pre Filter (washable) -
Ion Generator - Ion Generator -
CO2 Sensor ○ CO2 Sensor ○
Ventilation Kit - Ventilation Kit -
IR Receiver - IR Receiver -
Zone Controller - Zone Controller -
PDRYCB000 (1 point contact) PDRYCB000 (1 point contact)
Dry Contact (with additional accessory) Dry Contact (with additional accessory)
PDRYCB500 (Modbus) PDRYCB500 (Modbus)
External Input (1 point) - External Input (1 point) -
Wi-Fi - Wi-Fi -

※ ○ : Applied, - : Not applied ※ ○ : Applied, - : Not applied


Option : Refer to model name in table Option : Refer to model name in table

176 / 177
INDOOR _ VENTILATION SOLUTIONS _ KEY FEATURES INDOOR _ VENTILATION SOLUTIONS _ SPECIFICATION

ERV WITH DX COIL ERV WITH DX COIL


Providing Cool & Warm Fresh Air
During the summer, ERV DX can transform outdoor warm air into cool air for indoors, LZ-H050GXH4 / LZ-H080GXH4
and it can prevent cold draft during the winter by supplying warm air. LZ-H100GXH4 / LZ-H050GXN4
LZ-H080GXN4 / LZ-H100GXN4

Cooling Heating

Model LZ-H050GXH4 LZ-H080GXH4 LZ-H100GXH4 LZ-H050GXN4 LZ-H080GXN4 LZ-H100GXN4


Fresh Air Cooling kW 4.93 7.46 9.12 4.93 7.46 9.12
Conditioning Load Heating kW 6.73 9.80 11.72 6.73 9.80 11.72
Temperature
SH / H / L % 86 / 86 / 87 80 / 80 / 81 76 / 76 / 78 86 / 86 / 87 80 / 80 / 81 76 / 76 / 78
Exchange Efficiency
Enthalpy Exchange Cooling (SH / H / L) % 61 / 61 / 63 50 / 50 / 53 45 / 45 / 50 61 / 61 / 63 50 / 50 / 53 45 / 45 / 50
Efficiency Heating (SH / H / L) % 76 / 76 / 77 67 / 67 / 69 64 / 64 / 66 76 / 76 / 77 67 / 67 / 69 64 / 64 / 66
Operation Range Outdoor air Temperature °C -15 ~ 45 -15 ~ 45 -15 ~ 45 -15 ~ 45 -15 ~ 45 -15 ~ 45

VENTILATION
SOLUTIONS
Heat Exchange Mode (SH / H / L) CMH 500 / 500 / 440 800 / 800 / 640 1,000 / 1,000 / 820 500 / 500 / 440 800 / 800 / 640 1,000 / 1,000 / 820
Air Flow Rate
Bypass Mode (SH / H / L) CMH 500 / 500 / 440 800 / 800 / 640 1,000 / 1,000 / 820 500 / 500 / 440 800 / 800 / 640 1,000 / 1,000 / 820
Fan External Static Pressure (SH / H / L) Pa 160 / 120 / 100 140 / 90 / 70 110 / 70 / 60 180 / 150 / 110 170 / 120 / 80 150 / 100 / 70
System Natural Evaporating Type -
Humidifier Amount kg/h 2.70 4.00 5.40 -
Total Air Conditioning Solution Pressure Feed Water
Heat Exchange Mode (SH / H / L)
Mpa
dB(A) 38 / 36 / 33
0.02 ~ 0.49
39 / 37 / 34 40 / 38 / 35 39 / 37 / 35
-
41 / 38 / 36 41 / 39 / 36
LG ERV DX can be used as a Total Air Conditioning Solution. It can control condition of incoming air with the DX coil Sound Pressure
Bypass Mode (SH / H / L) dB(A) 39 / 37 / 34 40 / 38 / 35 40 / 38 / 35 39 / 37 / 35 41 / 38 / 36 41 / 39 / 36
and humidifier for making comfortable indoor air. In the summer, LG ERV DX provides air conditioning by cooling and Refrigerant R410A

ERV DX
Power Supply Ø, V, Hz 1, 220-240, 50,60
dehumidifying incoming air. During winter, warm air is provided by heating and humidifying incoming air. Power Input Heat Exchange Mode (SH / H / L) kW 0.25 / 0.20 / 0.15 0.42 / 0.35 / 0.25 0.48 / 0.42 / 0.27 0.25 / 0.20 / 0.15 0.42 / 0.35 / 0.25 0.48 / 0.42 / 0.27
(Nominal) Bypass Mode (SH / H / L) kW 0.25 / 0.20 / 0.15 0.42 / 0.35 / 0.25 0.48 / 0.42 / 0.27 0.25 / 0.20 / 0.15 0.42 / 0.35 / 0.25 0.48 / 0.42 / 0.27
Nominal Running Heat Exchange Mode (SH / H / L) A 1.5 / 1.3 / 1.0 2.5 / 2.0 / 1.5 3.6 / 3.2 / 2.3 1.5 / 1.3 / 1.0 2.5 / 2.0 / 1.5 3.6 / 3.2 / 2.3
Current (RLA) Bypass Mode (SH / H / L) A 1.5 / 1.3 / 1.0 2.5 / 2.0 / 1.5 3.6 / 3.2 / 2.3 1.5 / 1.3 / 1.0 2.5 / 2.0 / 1.5 3.6 / 3.2 / 2.3
Heat exchange DX Coil Humidification Air to air cross flow total heat Air to air cross flow total heat
Heat Exchange System
(sensible + latent heat) exchange (sensible + latent heat) exchange
Heat Exchange Element Specially processed non-flammable paper Specially processed non-flammable paper
Air Filter Multidirectional fibrous fleeces Multidirectional fibrous fleeces
Dimensions WxHxD mm 1,667 x 365 x 1,140 1,667 x 365 x 1,140
Exhaust Supply
Net Weight kg 105 98
Air Air
Liquid mm Ø6.35 Ø6.35
Gas mm Ø12.7 Ø12.7
Piping Connection Water mm Ø6.35 -
mm
Drain Pipe (Internal Dia.) Ø25 (1) Ø25 (1)
(inch)
Connection Duct Diameter mm Ø250 Ø250
Outdoor Return
Air Air Note : 1. Cooling Capacity Test condition - Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB
2. Heating Capacity Test condition - Indoor temperature : 20°C DB / Outdoor temperature : 7°C DB, 6°C WB
3. Humidifying capacity is based on the following conditions - Indoor temperature : 20°C DB, 15°C WB / Outdoor temperature : 7°C DB, 6°C WB
4. Cooling and heating capacities are based on the following conditions. : Fan is based on High and Super-high.
5. The operating sound measured at the point 1.5 m below the center of the unit is converted to that measured at an anechoic chamber.
6. The specifications, designs and information here are subject to change without notice.

Accessories
Chassis LZ-H050GXH4 LZ-H080GXH4 LZ-H100GXH4 LZ-H050GXN4 LZ-H080GXN4 LZ-H100GXN4
Interlocking with MULTI V Drain Pump -
LG ERV DX can be interlocked with MULTI V. It can be controlled individually by a wired remote controller connected Cassette Cover -
to MULTI V indoor units. Refrigerant Leakage Detector PRLDNVS0
EEV Kit -
Independent Power Module -
Indoor Units ERV DX Robot Cleaner -
Pre Filter (washable) -
Ion Generator -
CO2 Sensor AHCS100H0
Ventilation Kit -
IR Receiver -
Zone Controller -
PDRYCB000 (1 point contact)
Dry Contact (with additional accessory)
PDRYCB500 (Modbus)
External Input (1 point) ○
Wi-Fi -

※ ○ : Applied, - : Not applied


Outdoor Option : Refer to model name in table

178 / 179
CONTROL
SOLUTIONS

INDIVIDUAL CONTROL / CENTRALIZED CONTROL

INTEGRATION DEVICE

180 / 181
LG CONTROL SOLUTIONS
MULTI V 5 offers a diverse range of effective control solutions that satisfy specific needs of each building and its user scene.
These control systems are equipped with user-friendly interface, flexible interlocking environment, energy management and smart
individual controller for optimized controlling conditions and smart building management.

HOTEL OFFICE

Hotel Room Solution Central Control Solution

3rd Party BMS Cloud System

• Energy Management

SOLUTION
CONTROL
• External Device

Lighting Pump Fan CO2 Temp.


Sensor Sensor

APARTMENT RESIDENTIAL SMALL BUILDING

Power Distribution Solution Smart Individual Control Solution Small Central Control Solution

Integration Solution
182 / 183
INDIVIDUAL CONTROL

FEATURE FUNCTIONS
INDIVIDUAL Controller Name
Premium
Wired Remote Controller

Standard III Standard II Simple Simple(Hotel)


Wireless
Remote
Controller
Wi-Fi
Controller

CONTROL
Model Name

PREMTA000
PREMTB100 PREMTB001 PQRCVCL0Q PQRCHCA0Q NEW
PREMTA000A PWFMDD200
PREMTBB10 PREMTBB01 PQRCVCL0QW PQRCHCA0QW PWLSSB21H (H/P)
PREMTA000B

On / Off ○ ○ ○ ○ ○ ○ ○

Fan Speed Control ○ ○ ○ ○ ○ ○ ○

Temperature Setting ○ ○ ○ ○ ○ ○ ○

Mode Change ○ ○ ○ ○ - ○ ○

Auto Swing ○ ○ ○ ○ ○ ○

Vane Control
○ ○ ○ ○ ○ ○ ○
Basic (Louver Angle)

E.S.P
○ ○ ○ ○ ○ - -
(External Static Pressure)

Electric Failure
○ ○ ○ ○ ○ - ○
Compensation

Indoor Temperature Display ○ ○ ○ ○ ○ ○

ALL Button Lock


○ ○ ○ ○ ○ - -
(Child Lock)

SOLUTION
CONTROL
Schedule / Timer Weekly~Yearly Weekly~Yearly Weekly - - Sleep / On / Off Weekly

Additional Mode Setting 1)


○ ○ ○ - - - -

Time Display ○ ○ ○ - - ○ -

Humid. Display ○ ○ - - - - -

Advanced Lock
(mode, set point, set point Advanced Lock Advanced Lock - - - - -
range, On / Off Lock)
Advanced
Filter Sign ○ ○ ○ - - - -

Energy Management 2) ○ ○ ○ - - - -

Dual Set Point ○ ○ - - - - -

Human Detection - ○ - - - - -

Temp, Humidity
○ ○ - - - - -
Compensation

Wi-Fi AP Mode Setting ○ ○ ○ ○ ○ ○ -

Operation Status LED ○ ○ ○ ○ ○ - -

Wireless Remote Controller


○3) - ○3) ○3) ○3) - -
Receiver

ETC Display 5 inch Color 4.3 inch Color 4.3 inch mono 2.6 inch mono 2.6 inch mono 2 inch mono -

Size (W x H x D, mm) 137 x 121 x 16.5 120 x 120 x 16 120 x 120 x 16 64 x 120 x 15 64 x 120 x 15 51 x 153 x 26 -

Black Light Control for


○ ○ - - - - -
Screen Saver

※ ○ : Applied, - : Not Applied


1) It might not be indicated or operated at the partial product
2) Centralized control (PACEZA000 / PACS5A000 / PACP5A000 / PLNWKB000) and PDI (PQNUD1S40 / PPWRDB000) should be installed for this function
3) For ceiling type duct
Note : 1. Indoor unit should have functions requested by the controller
2. If you need more detail, please refer to the manual of product. (http://partner.lge.com: Home> Doc.Library> Manual)

184 / 185
INDIVIDUAL CONTROL

STANDARD III WIRED REMOTE CONTROLLER


4.3 inch colored screen with modern design Energy Savings
Energy Management
Model Name PREMTB100 / PREMTBB10
- Energy Monitoring & Alarm
On / Off ○
Fan Speed Control ○
Real-time and day / week / month / year energy usage
Temperature Setting ○ monitoring is possible. In addition, it can set target for
Mode Change Cooling / Heating / Auto / Dehumidification / Fan energy usage and operation time, and alarm will be
Energy-Saving Cooling / Robot Cleaning / Heater /
Additional Mode Setting 1)
Humidification / Comfort Cooling
displayed when exceeded.
Instantaneous Power Check Energy Usage Target Setting
Auto Swing ○ * PDI (PQNUD1S40 / PPWRDB000) is required.
Vane Control (Louver direction) ○
PREMTB100 (White) PREMTBB10 (Black) E.S.P

(External Static Pressure) 2)
Reservation Simple / Sleep / On & Off timer / Weekly / Yearly / Holiday Time Limit Control
Time Display ○ - The time-limit operation controls product by amount of
Features & Benefits Electric Failure Compensation ○
time. By setting the device operation time in advance,
Lock All / On & Off / Mode / Set temperature range
• The optimized controller for MULTI V 5 Filter Sign ○ (Remain time + Alarm) users can control for how long a device works and have
- Humidity sensor embedded Check Energy Usage 3) / Check Operation Time / Target Setting it stop automatically.
Energy Management (Energy, Operation Time) / Time Limit Operation / Alarm Popup
- Comfort cooling setting / Initialization Usage Data
- Smart Load Control setting Operation Status LED ○
Indoor Temperature Display ○
- Outdoor unit low noise setting
Indoor Humidity Display ○
- Defrost mode setting Human Detection ○
• New modern design & easy interface Display 4.3 inch TFT color LCD (480 x 272)
- Seamless design / Touch button Size (W x H x D, mm) 120 x 120 x 16
- 4.3 inch color LCD / Intuitive GUI Black light for Screen saver ○
2 Set Points Control

SOLUTION
CONTROL
Home Leave 2 set points control
• Energy saving functions
※ ○ : Applied, - : Not Applied Auto Changeover for convenience
- Instantaneous power monitor Temperature
1) It might not be indicated or operated at the partial product -W
 ith 2 set points control function, indoor unit manages
- Energy consumption check 2) This function is available for duct type
3) This function requires PDI (PQNUD1S40 / PPWRDB000) to be installed. room temperature automatically.
(power consumption, operation time) Note : 1. Indoor unit needs to have functions requested by the controller Cooling set point
2. 2 set points control works normally with MULTI V Heat Recovery and Single Split for Unoccupied Cooling
- Temp. Setback timer, time limit control Heat Pump. But in case of MULTI V Heat Pump, It may not work properly Setback for energy savings and comfort Cooling Set Point
- Target setting (ODU capacity, Instantaneous power) - In the user's absense, the room temperature will remain for Occupied
Occupied Unoccupied
• Group control between two set points rather than switching off providing Heating Set Point
for Occupied
- Up to 16 Indoor units can be controlled with one quick comfort when the mode is changed to occupied. Heating
Heating Set Point
remote control * This function is for Heat Recovery system or Single heat pump. Otherwise it is not for Unoccupied
guaranteed. Cooling Heating
• External device On / Off (1 point)
Time
- Customized interlocking control with indoor unit is Arrive at a room Leave a room
possible without dry contact Thermo-off
• 2 set points control Indoor temperature

- Increase convenience and comfort


- Auto changeover, Setback (home leave)
External Device On / Off
External Equipment Control Customized Interlocking Control
User can turn the external User can create a control scenario
equipment off or on through where the external heater
contact point output. switches on when temperature
Comfort Level drops below or rises above a
certain temperature.

Touch Button
Schedule Function
Simple Schedule Status Exception Day settings
Energy Contents Standard III remote controller Possible to set up exceptional
provides clock type daily schedule. date on regular schedule.

Cool Heat Dry Fan Auto

Error History

186 / 187
INDIVIDUAL CONTROL

PREMIUM WIRED REMOTE CONTROLLER STANDARD II WIRED REMOTE CONTROLLER


5 inch full touch screen with a premium design. Providing easy control of one or a group of indoor units with various functions.

Model Name PREMTA000 / PREMTA000A / PREMTA000B Model Name PREMTB001 / PREMTBB01


On / Off ○ On / Off ○
Fan Speed Control ○ Fan Speed Control ○
Temperature Setting ○ Temperature Setting ○
Mode Change Cooling / Heating / Auto / Dehumidification / Fan Mode Change Cooling / Heating / Auto / Dehumidification / Fan
Energy-Saving Cooling / Robot Cleaning / Heater / Energy-Saving Cooling /
Additional Mode Setting 1) Additional Mode Setting
Humidification Robot Cleaning / Heater / Humidification
Auto Swing ○ Auto Swing ○
Vane Control (Louver direction) ○ Vane Control (Louver direction) ○
E.S.P E.S.P (External Static Pressure) ○
○ Reservation Simple / Sleep / On / Off / Weekly / Holiday
PREMTA000 1) / PREMTA000A 2) / PREMTA000B 3) (External Static Pressure) 2) PREMTB001 (White) PREMTBB01 (Black) Time Display ○
Reservation Simple / Sleep / On / Off / Weekly / Yearly / Holiday
1) English / Portuguese / Spanish / French Electric Failure Compensation ○
2) English / Italian / Russian / Chinese Time Display ○
3) English / German / Polish / Czech Electric Failure Compensation
Child Lock


Features & Benefits Child Lock
Filter Sign

○ (Remain time + Alarm)
Operation Status LED ○
Filter Sign ○ (Remain time + Alarm) • Wired remote controller that can implement various Indoor Temperature Display ○
Features & Benefits Energy Management
Check Energy Usage3) / Check Operation Time / Target
Setting (Energy, Operation Time) / Time Limit Opera- functions such as scheduling or filter alert. Wireless Remote Controller
○1)
tion / Alarm Popup / Initialization Usage Data Receiver
• Full Touch screen Operation Status LED ○ Size (W x H x D, mm) 120 x 120 x 16
Blacklight ○
• The optimized controller for MULTI V 5 Indoor Temperature Display ○
Power Consumption Monitoring ○2)
Wireless Remote Controller
- Comfort cooling setting Receiver
○4) Check Model Information ○
- Smart Load Control setting Display 5 Inch TFT color LCD (480 x 272) ※ ○ : Applied, - : Not Applied
Size (W x H x D, mm) 137 x 121 x 16.5 1) For ceiling type ducted unit
- Outdoor unit low noise setting Black Light for Screen Saver ○ 2)This function requires PDI (PQNUD1S40 / PPWRDB000) to be installed.
Note : Indoor unit needs to have functions requested by the controller
- Defrost mode setting Home Leave 2 Set Points Control
• Design with user’s convenience ※ ○ : Applied, - : Not Applied
1) It might not be indicated or operated at the partial product
- Intuitive GUI 2) This function is available for duct type

SOLUTION
CONTROL
SIMPLE WIRED REMOTE CONTROLLER
- Main display simple mode 3) This function requires PDI (PQNUD1S40 / PPWRDB000) to be installed.
4) For ceiling type ducted unit
- 5 inch color LCD Note : 1. Indoor unit needs to have functions requested by the controller
2. 2 set points control works normally with MULT V Heat Recovery and Single Split Heat
• Energy saving functions Pump. But in case of MULTI V Heat Pump, It may not work properly
- Instantaneous power monitor A simple way to control office or hotel systems in a compact design
- Energy consumption check
(power consumption, operation time) Model Name PQRCVCL0QW / PQRCHCA0QW /
PQRCVCL0Q PQRCHCA0Q
- Temp. Setback timer, Time limit control On / Off ○ ○
- Target setting (ODU capacity, Instantaneous power…etc) Fan Speed Control ○ ○
Temperature Setting ○ ○
• Group control Cooling / Heating / Auto /
Mode Change -
-U  p to 16 Indoor units can be controlled with one remote control Dehumidification / Fan
Auto Swing ○ ○
• 2 set points control Vane Control (Louver direction) ○ ○
- Increase convenience and comfort E.S.P (External Static Pressure) ○ ○
Electric Failure Compensation ○ ○
- Auto changeover, Setback (home leave) PQRCVCL0QW (White) / PQRCHCA0QW (White) / Child Lock ○ ○
PQRCVCL0Q (Black) PQRCHCA0Q (Black) Indoor Temperature Display ○ ○
Wireless Remote Controller
Easy Energy Management Receiver
○1) ○1)
Full Touch
Screen
- Check the operation hour or electricity usage
-C  omparison of usage compared to last year
Features & Benefits Size (W x H x D, mm)
Blacklight
70 x 121 x 16

70 x 121 x 16

-S  et the target usage and time • Small remote control with minimal functionality ※ ○ : Applied, - : Not Applied
1) For ceiling type ducted unit
Note : Indoor unit needs to have functions requested by the controller
Easy Scheduling
-D
 aily, Weekly, Yearly schedule function
-S
 chedule pattern setting

WIRELESS REMOTE CONTROLLER


-S
 chedule copy

2 Set points Control Temperature

-A
 uto changeover switching the operation Cooling Model Name PWLSSB21H (H/P)
Upper
mode automatically Temperature limit On / Off ○
-S
 etback (Home Leave) Changing status by Lower
Auto Changeover Setback Fan Speed Control ○1)
occupied / unoccupied Temperature limit Temperature Setting ○
Heating
Mode Change Cooling / Heating / Auto / Dehumidification / Fan
* This function is only for Heat Recovery system
and Single heat pump. Time Plasma Purification / Energy-Saving Cooling /
Leave For Home Leave For Home Additional Mode Setting
Robot Cleaning / Auto Dry
Group Control Auto Swing ○
Indoor unit 1 Indoor unit 2 Indoor unit 3 Vane Control (Louver direction) ○
1.Max. 16 Indoor units by one remote controller. NEW
1 Master
1 Slave Slave
Reservation Sleep / On / Off
Time Display ○
Red (12V)
Yellow (Sig)
Black (GND)
Yellow (Sig)
Black (GND)
Yellow (Sig)
Black (GND) PWLSSB21H (H/P) Indoor Temperature Display ○
Sleep Mode Auto Max. 7 hours
2 2 Features & Benefits Size (W x H x D, mm) 51.4 x 153 x 26
Master ※ ○ : Applied, - : Not Applied
• Easy to use while moving • Main functions are available 1) For some products, you can use “slow” fan speed function.

188 / 189
INDIVIDUAL CONTROL

LG Wi-Fi MODEM
Control LG air conditioners by using internet devices as Android or iOS smartphones. LG ThinQ Connectivity
Model Name PWFMDD200
Size (W x H x D, mm) 48 x 68 x 14 LG ThinQ
Interfaceable Products MULTI V Indoor unit 3)
Connection Type Indoor unit 1:1
Communication Frequency 2.4 GHz ➋
Wireless Standards IEEE 802.11b/g/n
LG SmartThinQ (Android v4.1(Jellybean) or higher, iPhone
Mobile Application
iOS 9.0 or higher)
PWFMDD200 Optional Extension Cable PWYREW000 (10m extension)

1) Vane Control may not be possible according to the type of Indoor unit ➊ ➊ ➌
2) LG Centralized controller and PDI installation is required for this function
Features & Benefits 3) For the compatibility with Indoor unit, please contact regional LG office
Note : 1. Functionality may be different according to each IDU model
2. User interface of application shall be revised for its design and contents improvement
• User can enjoy anytime, anywhere access with Wi-Fi 3. Application is optimized for smartphone use, so it may not be well functioning with tablet
equipped device through LG's ThinQ mobile app. devices Internet
Service Provider
• This allows the user to access the unit remotely to Wireless AP
switch unit on or off before or after leaving the vicinity. (Router)
• LG’s exclusive Home Appliances control app(SmartThinQ)
is available Connection (Pairing) Order
• Simple operation for various functions ➊ Make LG account on LG Smart ThinQ and select the Router that will be used
- On / Off ➋ Insert passwords of selected router and set AP(Access Point) by LG remote controller
- Operation Mode ➌ Confirm the pairing between Wi-Fi Modem and Router
- Current/Set Temperature

SOLUTION
CONTROL
- Fan Speed
- Vane Control 1)
- Reservation (Sleep, Weekly On / Off) ThinQ Mobile App
- Energy Monitoring 2)
- Filter Management Simple operation for various functions
Controlling Reservation Energy
- Error Check & Monitioring Monitoring On / Off, Current Temp Mode, Set Temp Vane Control

Overview

Wi-Fi
Modem ThinQ Server

USB Wire

Easy Management
Reservation Energy Monitoring Smart Diagnosis Filter Management
LG ThinQ
* Search “LG SmartThinQ” on Google market or Appstore then download the app.
* Internet service with Wi-Fi connection has to be available.

Installation Scene Control box

Indoor unit PCB

Control panel
USB cable Wi-Fi modem

* Each indoor unit has a Wifi modem installation location inside the product, and it can be installed by exposure if necessary.

190 / 191
CENTRALIZED CONTROL

CENTRALIZED CONTROLLER FEATURE LIST


CENTRALIZED Controller Name AC Ez AC Ez Touch AC Smart 5 5) ACP 5 5) ACP Lonworks AC Manager 5 3)

CONTROL Model Name

PQCSZ250S0 PACEZA000 PACS5A000 PACP5A000 PLNWKB000 PACM5A000


DO - - 2 4 2 -
DI - 1 2 10 2 -
IDUs 32 64 128 256 64 8,192
Product ERV 32 64 128 256 64 8,192
Max.
Connectable A/C + ERV 32 64 128 256 64 8,192
No.
AHU - - 16 16 16 4)
16x32
Chiller - - 5 Optional 2) 10 Optional 2) - 10x32
Air Conditioner ○ 1) ○ ○ ○ ○ ○
Ventilation (ERV / ERV DX) ○ 2) ○ ○ ○ ○ ○
Heating - ○ ○ ○ ○ ○
Compatibility
AHU - - ○ ○ ○ ○
Chiller - - ○ 4) ○ 4) - ○
ACS IO - - ○ 4) ○ 4) ○ 4) ○
Add Drawing - - ○ 4)
○ 4)
○ 4) ○
Group Management - - ○ 4) ○ 4) ○ 4) ○

SOLUTION
CONTROL
Auto Changer Over - ○ ○ 4) ○ 4) ○ 4) ○

Additional Set Back - ○ ○ 4) ○ 4) ○ 4) ○


Function 2 Set - ○ ○ ○ ○ 4) ○
Change Alarm - Filter Filter Filter Filter Filter
Indoor Unit Lock - ○ ○ ○ ○ 4) -
Cycle - - ○ ○ ○ 4) ○
Schedule ○ ○ ○ 4) ○ 4) ○ 4) ○

Peak Priority Control - ○ ○ ○ ○ 4) ○


Control Outdoor Unit Capacity Control - - ○ 4) ○ 4) ○ 4) ○
Auto Control
Time limit control - - ○ 4) ○ 4) ○ 4) ○
InterLocking - - ○ 4) ○ 4) ○ 4) ○
Energy Navigation - - ○ 4)
○ 4)
- ○
Power - ○ ○ ○ ○ 4) ○
Gas - - ○ ○ ○ 4) ○
Energy
Run time - - ○ 4)
○ 4)
○ 4) ○
Report
Email - - - - ○ 4) -
PC / USB - - ○ 4) PC PC PC
Trend Reporting - - - - - ○
Report (Control / Error) - Error ○ 4)
○ 4)
○ 4)

History Send Email - - ○ 4) ○ 4) ○ 4) ○
Save to PC / USB 6) - - - - ○ 4) -
Summer Time - ○ ○ 4) ○ 4) ○ 4) ○
Outdoor Unit Oil-Return Operation - - ○ 4) ○ 4) ○ 4) -
etc
User Authority - Password ○ 4) ○ 4) ○ 4) ○
PC Access - ○ ○ 4) ○ 4) ○ 4) ○

※ ○ : Applied, - : Not Applied


1) Except for some feature (individual lock, limit, temp., etc.)
2) Except for some feature (user mode, additional function, etc)
3) ACP 5 or AC Smart 5 is required
4) This function is possible to use in Web Only (BMS Point is not applied)
5) Without additional device, ACP 5 and AC Smart 5 provide BACnet IP and Modbus TCP interface for BMS
6) Save to PC / USB function will be available from 4Q 2020

192 / 193
CENTRALIZED CONTROL

AC EZ TOUCH
Smart management with 5 inch touch screen for small site. Energy Mode Schedule
When using energy mode function, operation mode changes Schedule control allows user to set the events in advance
Model Name PACEZA000 from cooling to fan or heating to off mode by force. to maximize system performance. Also, by blocking
Size (W x H x D, mm) 137 x 121 x 25 (It is available only for operating indoor unit) unnecessary operation, it prevents a waste of energy.
Interfaceable Products MULTI V / ERV / ERV DX / HYDRO KIT / THERMA V
Maximum number of units 64
Individual / Group Control On & Off / Mode / Temperature / Fan speed
Individual Controller Lock Temperature / Mode / Fan speed / All
Error Check ○
Slave Mode (Interlocking with

PACEZA000 higher level controller)
Schedule Weekly / Monthly / Yearly / Exception day
Remote Access By client S/W
Features & Benefits Emergency Stop & Alarm

Display
• User-friendly control with iconographic interface
Power Consumption

• Total 200 schedule events Monitoring (with PDI)
• Energy saving mode Auto Changeover / Setback ○ Alarm Indicator Group / Individual Control
• Energy monitoring (with PDI) Temperature Limit ○ It shows errors and alarm information. Users can respond User can control each indoor unit individually or by group
Operation History Error record immediately according to alarm indicator therefore HVAC by simply clicking each unit on control screen.
• 2 set point function (upper / lower temperature setting)
ODU Low Noise 1) ○
• Temperature set points range limit system is monitored consistently.
Daylight Saving Time ○
• Remote controller lock (All, Temp, Mode, Fan Speed)
External IO Port DI 1
• Operation history
IPv6 Support ○
• Clean or change filter alert
※ ○ : Applied, - : Not Applied
• Emergency stop 1) It is only available in some products

SOLUTION
CONTROL
Overview

IDU
...

PC Internet AC EZ TOUCH

...
IDU AC EZ
Easy to manage up to 32 indoor units, including ERV with simple interface.

ERV Model Name PQCSZ250S0


Size (W x H x D, mm) 190 x 120 x 20
Interfaceable Products MULTI V / ERV / ERV DX
Display LED / LCD Display
Feature Power DC 12V

PC Access Energy Statistics (with PDI) Maximum number of units 32


Individual / Group Control On & Off / Mode / Temperature / Fan speed
Users can control each space efficiently through PC access. Statistics of operational status (time, power consumption)
Individual Controller Lock All
are provided to help make intelligent system operation PQCSZ250S0 Error Check ○
decisions. Slave Mode (Interlocking with

higher level controller)
Schedule Weekly

※ ○ : Applied, - : Not Applied

* IPv6 supported
Features & Benefits
• 32 indoor units control
• Weekly Schedule
• Individual / Group Control
Internet
Appropriate PI 485 should be • MULTI V 5 • MULTI V • MULTI V S • MULTI SPLIT • ERV
used according to PDB • MULTI V IV WATER IV • SINGLE SPLIT
* Fix Public IP is mandatory • MULTI V III • MULTI V
* Router´s Configuration of NAT is mandatory. Open port 80 & 9300 • MULTI V II WATER II

194 / 195
CENTRALIZED CONTROL

AC SMART 5
10-inch touch screen with HTML5 GUI (Graphic User Interface) for easy control. Building Management System (BMS) Integration Advanced Network Accessibility
Without additional device, AC Smart 5 provides BACnet IP & Modbus TCP inter- AC Smart 5 reflects the state of the art of network technology trend. IPv6
Model Name PACS5A000 face for BMS integration as well as its own management function. (Internet Protocol version 6), which is the most recent version of the Internet
Size (W x H x D, mm) 253.2 x 167.7 x 28.9 Protocol, provides accessibility to the IPv6 compatible network environment.
MULTI V / ERV / ERV DX / HYDRO KIT / In addition, HTML5 allows you to easily control LG HVAC system on a variety
Interfaceable Products
THERMA V / AHU kit / LG Chiller 1) of platforms (PC, Mobile, Tablet), at any time and from any location, not just
Maximum number of units 128 on the touch screen.
Individual / Group Control On & Off / Mode / Temperature / Fan speed BACnet over IP BMS
Individual Controller Lock Temperature / Mode / Fan speed / All
Comfort Cooling / ODU Low Noise / ODU Defrost Mode /
Advanced Function Setting and
Comfort Level display / CO2 Level display (for ERV /
Display 2)
ERV DX) / Night Time Free Cooling (for ERV / ERV DX)
Error Check ○
PACS5A000 Slave Mode (Interlocking with

higher level controller) IPv6
Schedule Weekly / Monthly / Yearly / Exception day Network
Features & Benefits Web Access ○
Emergency Stop & Alarm

• The central controller allows control of the LG Display
Power Consumption
HVAC system to various platforms. Monitoring (with PDI)
○ HTML5 web design
(Touch screen, PC, Smartphone, Tablet) Auto Changeover / Setback ○
Temperature Limit ○
- DI : 2 / DO : 2 Operation Time Limit ○
- Max. 128 IDU control Visual Navigation ○
Operation Trend ○
- BACnet IP/Modbus TCP
Interlock Control ○ Energy Management Visualized Control
- Schedule Virtual Group Control ○
The energy navigation function allows the air conditioners’ operational energy Visual navigation enables controlling and monitoring the unit on floor plan
- Map view (Visual navigation) ODU Capacity Control ○
usage to be manged monthly, weekly and yearly. By analyzing present energy view for the intuitive management.
Energy Navigation (with PDI) ○
- Time limit control / Auto change over Daylight Saving Time ○
consumption and comparing with the plan, overuse of system operational costs
- Energy monitoring External IO Port DI 2 / DO 2 can be prevented.

SOLUTION
CONTROL
BMS Integration 3) BACnet IP / Modbus TCP
- History / Operation trend
IPv6 Support ○
- Interlock with 3rd party equipment
※ ○ : Applied, - : Not Applied
(ACS IO, ACU IO Module is needed) 1) Chiller Option Kit (PCHLLN000) is required
2) It is only available in some products
- Multi level grouping 3) For the detail point list, please refer to the installation manual
- Emergency stop & alarm
- Error alarm by e-mail

Overview
IDU
Internet AC Smart 5

...
PC
Multi Level Group Composition Interlocking with 3rd party equipment
User can make frequent and multi level group to control and monitor the device AC Smart 5 can make operation scenario with 3rd party equipment by ACS IO
...
easily. Module. Control coverage is expanded. (Air conditioner only → Sensors, Fans,
Pumps, Switches…)
Smartphone
ERV LG SAC
ODU

OR OR
Tablet Chiller AHU Air Water Hydro Kit IDUs
ACS IO Option kit AHU Controller AC Smart 5 cooled cooled

3rd party interlocking Chiller AHU Comm. kit 3rd party interlocking
Sensor Facility Sensor Facility

Temp. CO2 Cooling Emergency


Motion Temp. CO2 Cooling Pump Centrifugal Absorption tower
tower
Etc. Occupancy
Valve Fan

...
Sensor
Screw Invert Scroll
Emergency Lighting Valve Fan Expansion
Control coverage
* Fix Public IP is mandatory Temp. Lighting
* Router´s Configuration of NAT is mandatory. Open port 80 & 9300 ACS IO

196 / 197
CENTRALIZED CONTROL

ACP 5 ACP LONWORKS GATEWAY


Advanced solution for BMS integration up to 256 units via BACnet and Modbus protocol as well as its own smart LonWorks easily link LG air conditioners and other existing building systems. By including ACP control function,
management function with web server interface. the controlling continues even when error occurs with BMS.

Model Name PACP5A000 Control Monitoring


Size (W x H x D, mm) 270 x 155 x 65 On / Off Command On / Off
MULTI V / ERV / ERV DX / HYDRO KIT / Operation Mode Setting Operation Mode
Interfaceable Products
THERMA V / AHU kit / LG Chiller 1)
Maximum number of units 256 Lock Lock
Individual / Group Control On & Off / Mode / Temperature / Fan speed Temperature Temperature
Individual Controller Lock Temperature / Mode / Fan speed / All Fan Level Fan Level
Comfort Cooling / ODU Low Noise / ODU Defrost Mode / Fan Direction Auto Fan Direction Auto
Advanced Function Setting and
Comfort Level display / CO2 Level display (for ERV / ERV DX) /
Display 2) Mode Lock Mode Lock
Night Time Free Cooling (for ERV / ERV DX)
Error Check ○ Fan Level Lock Fan Level Lock
PACP5A000 Schedule Weekly / Monthly / Yearly / Exception day
PLNWKB000
Temperature Lock Temperature Lock
Web Access ○ Temperature Lower Limit Temperature Lower Limit
Emergency Stop & Alarm
Features & Benefits Display
○ Features & Benefits Temperature Higher Limit Temperature Higher Limit
Power Consumption Peak Convert Cycle Peak Convert Cycle

• The central controller allows control of the LG HVAC Monitoring (with PDI) • Connect to use LonworksⓇ protocol and LG air Peak Setting Peak Setting
Auto Changeover / Setback ○
system by various platforms. (PC, Smartphone, Tablet) Temperature Limit ○
conditioner protocol. Temperature Unit Temperature Unit
Total Temperature Lock -
- DI :10 / DO : 4 Operation Time Limit ○ • Process ability (Max. connection) : Indoor unit
Visual Navigation ○ Total On / Off -
- Max. 256 IDU control 64EA, AHU Control Kit : Max. 16EA
Operation Trend ○ Total Temperature -
- BACnet IP/Modbus TCP Interlock Control ○ • Self installation verification using internet - Product Type
- Schedule Virtual Group Control ○ (Web Server Included) - Diagnosis of communication - Product Address
ODU Capacity Control ○
- Map view (Visual navigation) Energy Navigation (with PDI) ○
status on LG Air-conditioner network - Current Temperature
- Alarm
- Time limit control / Auto change over Daylight Saving Time ○ • It offers a variety of functions as ACP which allows
External IO Port DI 10 / DO 4 - Power
- Energy monitoring the customer to efficiently control various types of - Error Code

SOLUTION
BMS Integration 3) BACnet IP / Modbus TCP

CONTROL
- History / Operation trend IPv6 Support ○ equipment from the customer’s own Integration. - Peak Current Operating Percent
- Interlock with 3rd party equipment ※ ○ : Applied, - : Not Applied - Total Accumulate Power
(ACS IO, ACU IO Module is needed) 1) Chiller Option Kit (PCHLLN000) is required
※ ○ : Applied, - : Not Applied
2) It is only available in some products
- Multi level grouping 3) For the detail point list, please refer to the installation manual

- Emergency stop & alarm Overview


- Error alarm by e-mail

Overview CH5 BMS system


Lighting control Remote checking Utility control
Internet ACP 5 IDU
CH1 ~ 4 Indoor unit : Max. 64 units (Air conditioner & Ventilation) / Indoor address : 00 ~ FF

PC * Master
... 1)

Internet

Smartphone ... AC Smart 5


* Slave • MULTI V 5 • MULTI V • MULTI V S • MULTI SPLIT • ERV • AHU (Control Kit)
• MULTI V IV WATER IV • SINGLE SPLIT
• MULTI V III • MULTI V
OR OR Backup operation • MULTI V II WATER II
ERV
Chiller
ACS IO Option kit AHU Controller * Fix Public IP is mandatory Appropriate PI 485 should be used according to PDB (Product Data Book)
Tablet * Router´s Configuration of NAT is mandatory. Open port 80 & 9300
1) Assignment of public IP address is required to access central controller through internet.

3rd party interlocking Chiller AHU


AHU
Sensor Facility

Motion Temp. CO2 Cooling


tower
Pump Centrifugal Absorption
Comm. kit
PI 485
Etc.
PI 485 converts LG air conditioner’s protocol to the RS485 protocol for the central controller
Screw Invert Scroll
Emergency Lighting Valve Fan
• Power : C
 onnected with the
Multi level group / Indoor Units
Advanced Network Accessibility Energy Navigation BACnet IP & Modbus TCP Special control group
• 1 for Each Indoor Unit
BACnet over IP BMS - Indoor Unit (ERV)

IPv6
Network

PHNFP14A0
HTML5 web design
* Fix Public IP is mandatory
* Router´s Configuration of NAT is mandatory. Open port 80 & 9300

198 / 199
CENTRALIZED CONTROL

AC MANAGER 5
Multiple ACP and AC Smart integration solution to manage multi sites up to 8,192 units as a single system. Stand-alone
Integrated with S/W program and Hardware platform, it is
Model Name PACM5A000
convenient to install since users no longer need to install
Size (W x H x D, mm) 270 x 155 x 65
program with lock-key on PC.
MULTI V / ERV / ERV DX / HYDRO KIT /
Interfaceable Products
THERMA V / AHU kit / LG Chiller 1)
Maximum number of units 8,192 (supports 32 ACP 5 or AC Smart 5)
Individual / Group Control On & Off / Mode / Temperature / Fan speed
Individual Controller Lock Temperature / Mode / Fan speed / All
Error Check ○ Up to 8,192 Connections for Indoor Units Max. IDU 256 EA

PACM5A000 Schedule Weekly / Monthly / Yearly / Exception day


Administrators can easily and conveniently manage a ...
Web Access ○
Emergency Alarm Display ○
variety of LG HVAC equipment. Also, it is available to Max. IDU 128 EA
Features & Benefits Power Consumption manage many buildings or areas at one place via AC
○ ...
• Consol Type : No needs software installation and lock-key
Monitoring (with PDI) Manager 5.
Auto Changeover / Setback ○
• Max 8,192 IDU Control

...

...
Temperature Limit ○
• Schedule Operation Time Limit ○
Max. IDU 256 EA
• Map View (Visual Navigation) Visual Navigation ○ ...
• Time limit control / Auto change over Operation Trend ○
• Energy Monitoring / Navigation Interlock Control ○
• History / Operation Trend Virtual Group Control ○

• Emergency stop & alarm ODU Capacity Control ○ Advanced Network Accessibility & User Friendly GUI (reddot award)
Energy Navigation (with PDI) ○
• Error alarm by E-mail As an advanced central controller, AC Manager 5 offers flexible
• Multi Language ※ ○ : Applied, - : Not Applied
interface for each user by assessing the device screen and

SOLUTION
1) Chiller Option Kit (PCHLLN000) is required

CONTROL
(Eng, Ita, Spa, Por, Rus, Fra, Ger, Tur, Pol, Chi, Kor) Note : AC Manager 5 requires ACP 5 or AC Smart 5
automatically customizing the layout to provide the most
optimized interface.

Overview
AC Manager 5 ACP 5 ODU / IDU & ERV
AHU
PC Comm.kit
Energy Navigation & Energy Usage Trend
Internet
Chiller & AHU Energy navigation is the function to set the target usage
Chiller Option kit AHU Controller amount to limit the monthly power consumption and to
Mobile control so that the total accumulated power consumption
does not exceed the target usage amount. It performs
total of 7 control levels with the estimated/actual usage
3rd party Device
amount exceeding ratio compared to the monthly target
usage amount. For the control method, there are indoor unit
Tablet Compressor Capacity IDU operation IDU operation
ACS IO Module operation ratio, outdoor unit capacity control, and indoor Control Ratio Control level
ODU / IDU, ERV, Chiller, AHU, 3rd party Device
unit operation control.
AC Smart 5

* Fix Public IP is mandatory Operation ratio (IDUs) Control ODU Capacity Control
* Router´s Configuration of NAT is mandatory. Open port 80 & 9300 Peak Control
9 Step Operation rate (%)
This function can reduce electricity use. There are two kinds [ 0, 40, 45, 50, 60, 70, 80, 90, 100 ]
Indoor unit Priority Control
of control logic. Energy saving effect by indoor unit operation gradually stop depending on
importance of room.
rate control. Load management effect by outdoor unit capacity
control.
Robby  Office  VIP room Compressor Hz Control

AC Manager 5
AC Manager 5 Control tower
Multi Level Group Composition
ACP 5 ACP 5 AC Smart 5
User can make frequent and multi level group to control and
monitor the device easily.

200 / 201
CENTRALIZED CONTROL

MODBUS RTU GATEWAY MODBUS RTU GATEWAY


Providing Modbus RTU connection between LG Air conditioners and BMS. Holding Register (0 x 03)
Data Bit
No. Function Register
Air Conditioner ERV / DX ERV HydroKit & THERMA V
0 : Cooling, 1: Dehumidifying,
2 : Fan, 3 : Auto, 4: Heating Hydrokit
1 Operate Mode Operate Mode Connected IDU (Middle Temp. DHW)/AWHP
– 0 : Cooling, 3 : Auto, 4:Heating
Hydrokit(High Temp. DHW)
2 Fan Speed Fan Speed Target Temp. DHW 2) 1 : Low, 2 : Mid, 3 : High, 4 : Auto Register = N X 20 + ①
(N = Indoor Unit Central Address)
3 Target Temp. Target Temp. 1) Target Temp. 2) 16.0 ~ 30.0 [°C] x 10
4 Target Temp. Limit (Upper) Target Temp. Limit 1) (Upper) Reserved 16.0 ~ 30.0 [°C] x 10
5 Target Temp. Limit (Lower) Target Temp. Limit 1) (Lower) Reserved 16.0 ~ 30.0 [°C] x 10
6 Reserved Vent. Operate Mode Reserved 0 : HEX, 1 : Auto, 2 : Normal

* Note 1) : This register value is applied ‘DX Ventilator’ ONLY.


* Note 2) : This value range can be between 0 ~ 127[°C]. And it would be limited by upper & lower value according to the setting of remote controller.

PMBUSB00A Input Register (0 x 04)


Data Bit
Features & Benefits No.
Air Conditioner ERV / DX ERV HydroKit & THERMA V
Function Register

• Function 1 Error Code Error Code Error Code


0 ~ 255 ※ Please refer to the
product error table.
- MODBUS RTU communication with MODBUS - Size (W x H x D) : 53.6 x 89.7 x 60.7
2 Room Temp. RA Temp. Room Temp. -99.0 ~ 99.0 [°C] x 10
master controller -M ax. 16 IDUs with single module / Max. 64
3 Pipe In Temp. OA Temp. 1) Water Inlet Temp. -99.0 ~ 99.0 [°C] x 10 Register = N X 20 + ①
- MODBUS RTU slave (RS485) / 9,600 bps IDUs with 4 modules 4 Pipe Out Temp. SA Temp. 1) Water Outlet Temp. -99.0 ~ 99.0 [°C] x 10
(N = Indoor Unit Central Address)

- Applicable for MULTI V 5, MULTI V S, ERV, - Power : DC 12V 5 Reserved Pipe In Temp. 1) Sanitary Tank Temp. -99.0 ~ 99.0 [°C] x 10
THERMA V 6 Reserved Pipe Out Temp. 1) Solar Temp. 2) -99.0 ~ 99.0 [°C] x 10

SOLUTION
CONTROL
* Note : This register value is applied ‘DX Ventilator’ ONLY.
1)

* Note 2) : This register value is applied ‘AWHP’ ONLY.

Modbus Gateway Memory Map Installation Scene


Baud Rate : 9 600 bps, Stop Bit : 1 stop bit, Parity : None Parity, Byte size : 8 bits • Single module
Max. 16 indoor units with a single module
Coil Register (0 x 01)
Data Bit Modbus RTU
No. Function Register
Air Conditioner ERV / DX ERV HydroKit & THERMA V
1 Operate (On/Off) Operate (On/Off) Operate (On/Off) 0: Stop / 1: Run
2 Auto Swing Aircon Operate (On/Off) Hot Water Mode (On/Off) 0: Disable / 1: Enable
3 Filter Alarm Release Filter Alarm Release 1) Reserved 0: Normal / 1: Alarm Release BMS RS485 (LGAP)
4 Lock Remote Controller Lock Remote Controller Lock Remote Controller 0: UnLock / 1: Lock
5 Lock Operate Mode Lock Operate Mode 1) Reserved 0: UnLock / 1: Lock Register = N X 16 + ①
6 Lock Fan Speed Lock Fan Speed 1) Reserved 0: UnLock / 1: Lock (N = Indoor Unit Central Address)

7 Lock Target Temp. Lock Target Temp. 1) Reserved 0: UnLock / 1: Lock


8 Lock IDU Address Lock IDU Address 1) Reserved 0: UnLock / 1: Lock
9 Reserved Quick Ventilate Reserved 0: Disable / 1: Enable
10 Reserved EnergySave Reserved 0: Disable / 1: Enable

* Note 1) : This register value is applied ‘DX Ventilator’ ONLY.


• Multiple module
Max. 64 indoor units with 4 modules in one Modbus communication line
Modbus RTU
Discrete Register (0 x 02)
Data Bit
No. Function Register
Air Conditioner ERV / DX ERV HydroKit & THERMA V
1 Connected IDU Connected IDU Connected IDU 0 : Disconnected / 1: Connected
2 Alarm Alarm Alarm 0: Normal / 1: Alarm
BMS RS485(LGAP)
0 : Normal / 1: Alarm Hydrokit Register = N X 16 + ①
3 Filter Alarm Filter Alarm 1)
Hot Water Only 2)
– 0 : Normal / 1: Hot Water Only (N = Indoor Unit Central Address)
4 Reserved Reserved Target Temp Select 0: Air / 1: Water
5 Reserved Reserved Error Division 2) 0 : CH type error / 1: BC type error Max. 16 outdoor units in
one RS485(LGAP) line
* Note 1) : This register value is applied ‘DX Ventilator’ ONLY. * Note 2) : This register value is applied ‘Hydrokit’ ONLY.

202 / 203
INTEGRATION DEVICE

PDI (POWER DISTRIBUTION INDICATOR)


INTEGRATION PDI shows distributed power consumption of up to 128 indoor units

DEVICE
Model Name PQNUD1S40 PPWRDB000
Size (W x H x D, mm) 270 x 155 x 65
Interfaceable Products Air conditioner, ERV DX

Maximum Number of Power EHP : 8 Watt meter EHP : 2 Watt meter


GHP : 4
 Watt meter/ 4 GHP : 1 Watt meter/ 1
Meters Gas meter Gas meter
Maximum Number of
MULTI V : 128
Indoor Units
Data Backup When Power
PQNUD1S40 (Premium, 8 port) Outage

PPWRDB000 (Standard, 2 port) Power Input PDI : AC 24V, Transformer : AC 220V


※ ○ : Applied, - : Not Applied
Features & Benefits
• Enables total and indoor power consumption monitoring
• With LG central control connectivity, energy montioring, energy savings operations and target usage setting functions are enabled
• Enables gas consumption and electricity distribution

Pulse line
ACS Central controller

SOLUTIONS
SOLUTION
CONTROL
220 V~
ACP 5
24 V~

PDI power source RS485

BUS-A BUS-B AC Smart 5

50kW

Measurement
MENU

AC Manager 5 70kW
SELECT
(00) ~ (03)
160kW [00] [01] [02] [03]

ACP 5 50kW
[10] [11] [12] [13]
[ Slave 1]
[ Master ] [20] [21] [22] [23]
AC Smart5 ACP

Graphing [30] [31] [32] [33]

Note : 1. Power cable and type could be different from this scene depending on the Outdoor unit’s specification
2. Measured power consumption could be different between PDI and Watt meter
3. Applicable Central Controller : ACP 5, ACP Lonworks, AC Smart 5, AC Ez Touch
(Combination : we recommend to connect separated watt meter for Outdoor units to have correct power distribution value)

204 / 205
INTEGRATION DEVICE

ACS IO MODULE ACU IO MODULE


This module can be connected with ACP 5 or AC Smart 5 controller if additional I/O points such as DI/DO and This module can be connected with ACP 5 or AC Smart 5 controller if additional I/O points such as UIO / UI / UO
AI/AO for 3rd party devices control and monitoring are needed. for 3rd party devices control and monitoring are needed.

Model Name PEXPMB000 ACU.UIO ACU.UO ACU.UI Module Name PEXPMB300 PEXPMB200 PEXPMB100
PACS4B000 Linkable Products PACS5A000, PACP5A000
PACP4B000
Linkable Products Communication
PACS5A000 2 ch. 1) 1 ch. 1 ch.
PACP5A000 RS-485
Communication RS-485 1 ch. Digital Input - - 3port
Digital Input 3 port Digital Output 2port 6port -
Digital Output 3 port Universal Input 2) 4port - 6port
I/O
Universal Input 1) 4 port Analog Output 2port 4port
PEXPMB000 Analog Output 4 port PEXPMB300 PEXPMB200 PEXPMB100
Value Spec Min. Max.
Value Spec Min. Max. Analog Input DC (Voltage) 0V 10V
NTC 10k 0.68kΩ 177kΩ Analog Output DC (Voltage) 0V 10V
PT 1000 803kΩ 1,573kΩ Binary Input
Digital Input - -
(Non Voltage)
Analog Input Ni 1000 871.7kΩ 1,675.2kΩ
Digital Output Normal Open - 30VDC, 1A
DC (Voltage) 0V 10V
※ ○ : Applied, - : Not Applied
DC (Current) 0mA 20mA
1) 1ch is reserved for internal communication
Analog Output - 0V 10V 2) The type of UI (Universal Input) is selectable among Digital Input and Analog Input
Binary Input
Features & Benefits
Digital Input - -
(Non Voltage)
• Interlocking with 3rd party equipment LG Central controller can make operation scenario with 3rd party equipment by ACU IO Module.
Digital Output Normal open - 30VAC / 30VDC, 2A
• Applicable devices are expanded. (Air conditioner only → Sensors, Fans, Pumps, Switches …)
※ ○ : Applied, - : Not Applied
1) The type of UI (Universal Input) is selectable among Digital Input and Analog Input

SOLUTION
CONTROL
Features & Benefits
• Interlocking with 3rd party equipment LG Central controller can make operation scenario with 3rd party equipment by ACS IO Module.
• Control coverage is expanded. (Air conditioner only → Sensors, Fans, Pumps, Switches …) CHILLER OPTION KIT
LG central controller 5 series with Chiller Option Kit can provide LG chiller remote control and cycle monitoring.
Key Application
LG Central Control LG SAC Model Name PCHLLN000
ODU Evaporator status / Compressor status (Scroll, Screw,
Monitoring Points Centrifugal chiller only) / Condensor status /
Generator status (Abs. chiller only)
On / Off ○
Air cooled Water cooled Hydro Kit IDUs Target Temp. setting ○
AC Manager 5 ACP 5 Mode Change Scroll chiller only
ACS IO Module
3rd party interlocking Schedule ○
Sensor Facility Interfaceable Products Scroll, Screw, Centrifugal, Absorption (LG Only)
PCHLLN000
※ ○ : Applied, - : Not Applied

AC Smart 5 Temp. CO2 Occupancy Cooling Emergency Valve


tower
Fan Cycle Display Example Installation Scene
Sensor • Chiller Option Kit installation of LG HVAC Solution product
should be conducted by a specialized installation service
...

Expansion engineer.
Control coverage
• Chiller Option Kit installation can be achieved with a SD Card.
Temp. Lighting
• The SD Card can install Chiller Option Kit in one LG HVAC
Solution product.
* DI : Digital Input, DO : Digital Output, UI : Universal Input, AO : Analog Output / Please contact our regional office to have connectable relay specification for analog output
Insert the SD Card in the LG HVAC Solution product. If a backup
SD Card is inserted, replace it with a ChillerOption Kit SD Card.

206 / 207
INTEGRATION DEVICE

DRY CONTACT
Connection between an indoor unit and external devices to control various functions. PDRYCB000
Model Name PDRYCB000 PDRYCB400 PDRYCB300 PDRYCB320* PDRYCB500 Contact Point Input
CN - CC Dry contact
Operation On / Off
Indoor Unit (Contact point linked with 3rd party)
NEW Status
PCB
Error Alarm
CN - CC

Case ○ ○ ○ ○ ○ Key Lighting Fire Alarm Timer Motion Door Check


Switch Sensor Detect Sensor Sensor
Input Port 1 2 8 8 - System Structure

Universal Input port - - - 1 -

Comm. Protocol - - - - Modbus RTU


PDRYCB400
Power AC 220V Connect to Indoor unit PCB (CN_CC)
2 inputs interworking
Contact Point Input 1
On / Off ○ ○ ○ ○ ○
Contact Point Input 2 CN - CC
Indoor Unit
PCB Operation On / Off
Oper Mode - ○ ○ ○ ○
Status
Error Alarm Window Sensor
Set Temp. - (Select & Fix) (Select & Fix) (Select & Fix) ○ CN - CC

Aircon Fan Speed - - ○ ○ ○

SOLUTION
CONTROL
Card key
Thermo-Off - (Select & Fix) ○ ○ -

Energy Saving - (Select & Fix) - - - Refrigerant leakage detection alarm

Lock/Unlock - (Select & Fix) - - -


CN - CC

On / Off ○ - ○ ○ - Leakage Alarm

DHW On / Off - - ○ ○ -
Control
Thermo-Off - - ○ ○ - Card key Leakage Detector
AWHP
Oper Mode - - ○ ○ -

Silent Mode - - ○ ○ - PDRYCB300 / PDRYCB320


Emergency Mode - - ○ ○ - Target temperature setting (0~10V)
Operation On / Off CN - CC
On / Off ○ - - - ○ Thermo On / Off
Indoor Unit Operation Mode (Fan / Heat / Cool)
Oper Mode - - - - ○ PCB
Fan Speed (Low / Middle / High) Control Module
Vent Aircon Mode - - - - ○ Operation On / Off Status
CN - CC
Error Alarm
Additional Mode - - - - ○

Fan Speed - - - - ○
※ Please contact our regional office to have full compatible room controller list

Operation Status ○ ○ ○ ○ ○

Output Error ○ ○ ○ ○ ○
PDRYCB500 <Modbus Communication Function>
Room Temp. - - - - ○

※ ○ : Applied, - : Not Applied CN-CC


*Available from April 2020
Note : 1. Compatibility of PDRYCB300 / PDRYCB320
- Can use with all types of aircon indoor units after 2010 (Cassette, Ducted, Convertible, Applied PAC, Wall mounted, Console) Indoor Unit Modbus Master Controller
- Can not use with Single package models

...
- AWHP : 3 series split and monobloc models Max. 16 Indoor units per one
2. Compatibility of PDRYCB400 Modbus master controller
- Can use with all types of aircon indoor units after 2010 (Cassette, Ducted, Convertible, Applied PAC, Wall mounted, Console) One to one connection between
- Can not use with single package models dry contact and indoor unit
- Can not use with AWHP, Hydrokit models
3. (Select & Fix) : This function is preset by rotary switch.
CN-CC

Indoor Unit

※ Please contact our regional office to check the compatibility with 3rd party room controller

208 / 209
INTEGRATION DEVICE

GROUP CONTROL WIRE LOW PROFILE REMOTE TEMPERATURE BUTTON SENSOR


Cables used to connect a wired remote controller up to 16 indoor units. Allows for easy and discreet installation as well as connection to an indoor unit

Model Name PZCWRCG3 Model Name ZRTBS01


Y-type Cable 0.25m Length Operation Range -40℃ to 85℃ (0 to 100%RH, Non-condensing)

Long Cable 9.6m Length Sensing Element Thermistor


Sensing Element Accuracy 0.2℃ (0 to 70℃)
Material Etched Teflon
Wire Leads Length 15m
Thickness 0.33mm2
Mounting 10mm hole, push in plastic sheath with peel off tape strip
PZCWRCG3 ZRTBS01 Enclosure Material Ratings Plastic, NEMA 1, UL94

Installation Scene Indoor 1 MAIN PCB

Indoor 1 Indoor 2 Indoor 3 Features & Benefits


Indoor terminal block Indoor terminal block Indoor terminal block
• Ideal for locations where aesthetics are as important as the temperature measurement
RED (12V) • Inconspicuous wall sensor that mounts easily by pushing through a 10mm hole and secured with a peel off tape strip
YL (SIGNAL) YL (SIGNAL)
YL (SIGNAL)
BK (GND) BK (GND)
BK (GND) • Small flush sensor mounting
• Accurate direct air measurement
• Paintable with latex or oil base

Note : 1 Y type Cable assembly is for connecting indoor unit and long cable.
2 Long Cable assembly is for connecting indoor to indoor.
Key Application Models Applied

SOLUTION
CONTROL
• LG indoor units excluding Wall-Mounted Type
Extension cable
Control
box

REMOTE TEMPERATURE SENSOR


Sensor for detecting the room temperature. Wired Remote
Controller
Low Profile
Button Sensor

Installation Scene Drawing


Adhesive Ring

PQRSTA0 Main PCB 22.2mm

Indoor Unit
Features & Benefits 9mm
1.6mm
• It detects the exact room temperature instead of indoor unit’s air temperature sensor
15.2mm
• Applied to Ceiling Mounted Cassette, Ceiling Concealed Duct, THERMA V and HYDRO KIT
• Extension cable (15m) is included

Main PCB
Installation Scene Extension Cable
CN-ROOM
1. Wire to the control box in the indoor unit by
Low Profile Remote
removing the existing thermistor and connect Temperature Button Sensor CN-ROOM Connector
the extension cable its place.
Indoor Unit
2. Cut the extension cable to the appropriate
length and connect the screw terminal of the
Remote Wired Remote
remote sensor. Temperature Sensor Controller

210 / 211
INTEGRATION DEVICE

ZONE CONTROLLER IO MODULE


Controls air conditioning in up to 4 zones by external thermostat. Interface module between system air conditioner’s outdoor unit and external device.

ROOM1 ROOM2 Models Applied


Indoor Unit
Thermostat Thermostat
(Duct Type) • MULTI V 5 • MULTI V WATER IV
• MULTI V S
Part Description

1) Digital Input Part (DI : Dry Contact Input)


• Demand control by contact input (3 Step)
ABZCA PVDSMN000 • Low Noise Operation input
•P riority Setting input : Setting the priority of demand control command
(Capacity control for external signal from DDC vs Peak control by LG
Features & Benefits Thermostat Thermostat
Features Central controller)
- Open : External signal has priority to central controller (Default)
• Controls different zones (up to 4 zones) by external Function - Close : Central controller has priority to external signal
Zone Control ROOM3 ROOM4
thermostat (AC 24V) sub PCB • Demand control
2) Analog Input Part (AI : DC 0 ~ 10V)
• Maintain proper air volume of each zone • Low noise operation
• Demand control by analog input (10 Step)
• Auto variation of dampers • Output outdoor or indoor unit operation status
• Auto control of fan speed and On / Off operation • Output error status 3) Digital Output Part (DO : AC 250V, Max. 1A)
• Error status relay output
• Operation status relay output
Description • Valve control
• IO Module is communication interface module for
connection between MULTI V 5 and external IO
Models Applied (Input / Output Module) devices.

SOLUTION
CONTROL
• Ceiling Concealed Duct (refer to Product Data Book for applicable models) Note : IO Module is not compatible for MULTI V III

Key Application
Wiring Diagram Demand Control Low Noise Operation
Provides variable setting for demand control according to input method to To reduce noise level , control outdoor unit’s fan speed by dry contact input.
reduce power consumption. This function supports 2 types of input signal : AI
(0 ~ 10V, 10 Step) and contact signal (3 Step).
Ceiling Concealed Duct
Max. 7 dB*
1
(dB)
2
3 DDC DDC
CN - ZONE 4 IO Module (Direct Digital Controller) IO Module (Direct Digital Controller) Timer
5
6 Capacity
7 Control with Noise Level or
8 MULTI V WATER IV
or
Contact Signal
(3 Points / 3 Steps) Contact Signal
AC 24V
Range of Operation Rate
ROOM(External) Damper AI 0 ~ 10V : 0%, 40% ~ 100%
THERMOSTAT #1 Or Relay Contact signal (3 steps) : 0%, 40% ~ 80%
MULTI V 5

Zone controller MULTI V 5 * 8 HP (22.4kW) model, Sound power level can be changed by outdoor unit operation
ROOM Damper status and low noise operation input signal.
THERMOSTAT #2 Or Relay

ROOM Damper Refrigerant Leakage detection with Pump-down


THERMOSTAT #3 Or Relay
For safety, IO module close refrigerant valve when Pump-down operation.

ROOM Damper 2. Valve Close


THERMOSTAT #4 Or Relay Liquid Pipe

Gas Pipe

IO Module
3. Operation Stop 1. Sense the Gas
MULTI V 5
Alarm
Gas Gas
Sensor Sensor
Refrigerant

212 / 213
INTEGRATION DEVICE

WATER COMMUNICATION MODULE NEW

This module is intended to connect 3rd party plate heat exchanger to LG outdoor unit
with the ability to control water temperature from 3rd party DDC or LG remote controller.

Contents Connection Port Function Compatibility & Accessory


CH1 (A+ / B-) Module Comm. Port Communication Port Modbus
RS485
CH2 (A+ / B-) IDU Comm. Port
Communication with Multi V EEV (LG MODEL)
Outdoor
UNIVERSAL UI1 Flow Switch Flow Switch Input by 3rd party Capacity (kW)
INPUT Model PAHCMW000
UI2 0 ~ 10V Set Temp Target Temp. Setting Min Max
(Cooling/ UI3 Cooling Thermostat Signal Thermostat Cooling Signal
Heating PAEEVC000 3.6 28 HP/HR
Setting) UI4 Heating Thermostat Signal Thermostat Heating Signal PRLK048A0 3.6 28 HP/HR
UI1 Flow Switch Flow Switch Input by 3rd party PRLK096A0 28.1 56 HP
UNIVERSAL UI2 0-10V Set Temp Target Temp. Setting
Note: Water communication module can accept plate heat exchangers from 3,6 to 112 kW for combination with Multi V Outdoor units
INPUT DHW Temperature Measured Water Temp Input
(DHW Only) UI3
Transmitter 0 ~ 10V by 3rd party 0 ~ 10 V sensor
UI4 DHW Thermostat Signal DHW Heating Signal
PAHCMW000 NTC
RI1 Water Inlet Sensor PHEX Water Inlet Sensor
RI2 Water Outlet Sensor PHEX Water Outlet Sensor
+12V / SIG /
REMO LG Remote Controller - LG Controllers
GND
SINGLE Reserved - -
Individual Controller Centralized Controller
Output for defrost signal Dry Contact
DO1 Defrost / Mode Controller Standard Ⅲ AC EZ touch AC smart 5
and/or cool mode
DIGITAL
DO2 Pump Output signal for pump on/off PREMTW101 PACEZA000 PACS5A000 PDRYCB000
OUTPUT
Output signal for PHEX Bypass
DO3 Bypass
Valve
RI3 Thermistor Pipe In PHEX Ref. Inlet Pipe Sensor
NTC
RI4 Thermistor Pipe Out PHEX Ref. Outlet Pipe Sensor
+12V / 1 / 2
EEV Expansion Valve EEV Control
/3 /4

SOLUTION
CONTROL
Features & Benefits
Interlocking with 3rd parties can make various solution with LG MULTI V outdoor unit. Specification for Field supply item
• The 3rd party can select the for best usable version

Solenoid valve for Bypass


Capacity (kW) Kv Value of solenoid and
EEV type System Pipe size
Min Max Non-Return Valve
PAEEVC000
Overview 3.6 28
PRLK048A0
HP/HR 0.95 3/8" / 9.52mm
>28 56 PRLK096A0 HP 1.9 1/2" / 12.7mm

Flow switch
3rd Party DDC •The nominal flow and cut of flow can be Controller Nominal Flow Flow switch Cut off
Modbus RTU / DI+AI
Water Communication LG Remote calculated using the values below. L/min*kW 3.29 1.23
Module Controller
• Example : ODU nominal Cooling Capacity 28 kW
28 x 3.29 = 92.12 L/min nominal flow
28 x 1.23 = 34.44 L/min flow switch cut off
FS ❹


❶ ❺
DHW
Refrigerant Side M Water Side
Tank
TT

1. EEV Heat
2. Solenoid Valve (NC)
Exchanger
3. Non-Return Valve
4. FS : Flow Switch
5. TT : DHW Temperature Transmitter

• 3rd party solenoid, non-return valve, heat exchanger, flow switch and DHW temperature transmitter(optional) must be purchased separately (field supplied items)

214 / 215
INTEGRATION DEVICE

WATER COMMUNICATION MODULE APPLICATION


Installation scene with Contact connection Installation scene with Modbus / LG Control(optional) connection 
Contact signal + DHW Only Setting Modbus+ DHW Only Setting

Water side
Water side
Water inlet (5m)
DHW On/Off Water inlet (5m) Modbus Water outlet (5m)
3rd Party
3 Party
rd Water outlet (5m) Controller
set temp (0~10V)
Controller
Error / Normal Flow switch (Field Supply)
Drycontact
(Option) Flow switch (Field Supply) DHW temp sensor
LG Central controller (Option)
Defrost / (0~10V)
LG Central controller (Option) Normal DHW temp sensor
(0~10V)
Filed Supply
Filed Supply Standard III Remote
Standard III Remote Controller (Option) Ref. side
Controller (Option) LGAP
Ref. side
LGAP

CH1 CH2 UI1 UI2 UI3 UI4 RI1 RI2


CH2 UI1 UI2 UI3 UI4 RI1 RI2
MULTI V
MULTI V
CN-CC

DO1 DO2 DO3 RI3 RI4 EEV


DO1 DO2 DO3 RI3 RI4 EEV

SOLUTION
pipe out (5m)

CONTROL
pipe out (5m) Bypass pipe in (5m)
Bypass pipe in (5m) On/Off
On/Off
3rd Party Solenoid
3rd Party Solenoid Valve (By Pass)
Valve (By Pass) + Non-Return Valve
+ Non-Return Valve
Filed Supply
EEV kit
Filed Supply
EEV kit

Contact signal + Heating / Cooling Setting Modbus+ Heating/Cooling Setting


Water side Water side

Pump Pump
Heating On/Off
Cooling On/Off
3rd Party 3rd Party Modbus
set temp(0~10V) Water inlet (5m) Water inlet (5m)
Controller Controller
Error / Normal Water outlet(5m) Water outlet(5m)
Drycontact
(Option)
Defrost /
LG Central controller (Option) Normal Flow switch (Field Supply) LG Central controller (Option) Flow switch (Field Supply)

Standard III Remote Standard III Remote


Controller (Option) Controller (Option)
LGAP LGAP

Ref. side Ref. side


CH2 UI1 UI2 UI3 UI4 RI1 RI2 CH1 CH2 UI1 UI2 UI3 UI4 RI1 RI2

MULTI V MULTI V
CN-CC

DO1 DO2 DO3 RI3 RI4 EEV DO1 DO2 DO3 RI3 RI4 EEV

Pump On/Off Pump On/Off


pipe out (5m) pipe out (5m)

Bypass pipe in(5m) Bypass pipe in(5m)


On/Off On/Off

3rd Party Solenoid 3rd Party Solenoid


Valve (By Pass) Valve (By Pass)
+ Non-Return Valve + Non-Return Valve

Filed Supply Filed Supply


EEV kit EEV kit

※ In case of Contact control, LG controllers can only support monitoring functions

216 / 217
INTEGRATION DEVICE

VARIABLE WATER FLOW CONTROL KIT LOW AMBIENT KIT


Accessory developed for controlling the water flow. External integration module for cooling operation with -25°C low ambient temperature.

PWFCKN000 PRVC2
(MULTI V WATER IV)
Features
Features Function
Function • 25°C Low ambient cooling operation by Low ambient kit and hood
• Water pump or valve control (0 ~ 10V) with damper (Analog output 0 ~ 10V)
• Minimum output voltage setting available • Demand control
• Operation, error output (AC 250V, Max. 1A) • Low noise operation
• Dry contact input and analog output for demand control • Output outdoor or indoor unit operation status (AC 250V, Max. 1A)
• Digital output for operation, error status (AC 250V, Max. 1A) • Output error status (AC 250V, Max. 1A)

Advantage Description
• Water flow consumption reduction • Low ambient kit supports -25° C cooling operation by making stable

SOLUTION
CONTROL
• Pump electricity consumption reduction condensing pressure with reducing air flow rate from hood and
• Including IO Module (Dry contact input, Analog input / output, Digital output) damper control given 0 ~ 10V proportional to condensing pressure.
: Using Dry contact and variable water flow control function simultaneously • Low ambient kit provides IO Module function. Front Back
• External snow hood and air damper are required for this item.
: Field Supply item
• Transformer and terminal block are included.

Wiring Diagram
Cooling Tower

Models Applied
• MULTI V 5
Single Line • MULTI V IV
Cooling Tower

Water Flow Line


0 ~ 10V (Analog output)

Flow
control
valve Pump / Cooling Tower
Controller
Installation Scene Reference : Air Damper

Main PCB
Flow
control
valve Pressure
sensor Damper Actuator
(0 ~ 10V)
Transformer
AC 220V
-> AC 220V
From Water Source

Inverter pump

MULTI V 5 IO Module
• Flow control valve : Regulates the flow or pressure of a fluid, normally responding to signals generated by independent devices. DC 0 ~ 10V
• Flow Meter : Measures mass flow rate of a fluid traveling through a tube. (The mass flow rate is the mass of the fluid traveling past a fixed point per unit time.) Common
• Pressure Sensor : Measures the pressure.
Control AC 24V

Note : The IO Module can control maximum three actuators. Please, review damper actuator’s installation manual.

218 / 219

Cooling Tower
INTEGRATION DEVICE

COOL / HEAT SELECTOR AHU KITS


Cooling only, heating only, and fan mode can be selected. A solution to connect LG’s high efficiency system to the DX coil of an air handling unit for the maximum energy savings.
NEW
COMMUNICATION KIT CONTROL KIT EEV KIT

PAHCMR000 PAHCMS000 PAHCNM000 PRLK048A0


PRDSBM
PRLK096A0
NEW
Features CONTROLLER MODULE NEW

• Indoor unit mode control without central controller


• Select operation mode : Cooling, Heating, Fan mode
• Mode lock for cooling & heating mixing error-proof during the change of season
PRLK396A0
Fan Mode Mode Change

PAHCMM000 PAHCMC000 NEW


Cooling Heating
only only +

SOLUTION
CONTROL
PRLK594A0

Specifications
Control Application Kit
Dimensions (mm) IP
Type Model Power Supply Description
W H D Rating
Return / Room air temperature control by DDC or LG
PAHCMR000 300 300 155 1Φ, 220~240 V, 50/60 Hz IP66
Communication individual / centralized controller.
Kit Discharge air / Supply air temperature control by DDC
Models Applied PAHCMS000 380 300 155 1Φ, 220~240 V, 50/60 Hz IP66
or LG individual / centralized controller

• MULTI V 5 • MULTI V WATER II • MULTI V WATER IV PAHCMM000 162 90 61 DC 12V IP20 Main Controller module
Controller
• MULTI V IV • MULTI V S Module
PAHCMC000 108 90 61 DC 12V IP20 Communication Controller module
• MULTI V WATER S • MUL TI V PLUS II, MULTI V PLUS
Various AHU control functions with multiple DX coils
Control Kit PAHCNM000 500 500 210 1Φ, 220~240 V, 50/60 Hz
(Maximum connectable ODU is 3 units)

Wiring Diagram Expansion Application Kit


Dimensions (mm) Pipe Diameter (mm)
Type Model Capacity Index Range
W H D Liquid
<Outdoor Main PCB >
PRLK048A0 217 404 83 12.7 3.6 ~ 28 kW
Push Button
• Connect Terminals (1, 2, GND) on the back side of the outdoor dry PRLK096A0 217 404 83 12.7 28.1 ~ 56 kW
Insert wire method contact to terminals (1, 2, GND) of outdoor as shown below. EEV Kit
PRLK396A0 349.5 345.5 180 19.05 56.1 ~ 112 kW

PRLK594A0 409.5 345.5 180 19.05 112.1 ~ 168 kW


Push arrow direction

Insert wire to * Communication line length can be maximum 300m, use


Field wiring connector Communication line as thick 1.25mm
Connected wiring

220 / 221
INTEGRATION DEVICE

AHU KITS
Communication Kit Single Split Application (Communication Kit & Controller Module)
HIGH ENERGY EFFICIENCY Single Split + Return / Room Air Temperature Control
LG's DX AHU solutions' superior perfomance provides
a highly efficient heat source system. Temp. Sensors
Comm. Line
Central Comm. Line to ODU
• High energy efficiency inverter system Ref. Pipe
• Large range of expansion application Kit AHU MULTI V 5
TE = Evaporator Temperature
: Max 168 kW EEV Kit1) (Liquid Pipe / Gas Pipe)
• Connected to various heat sources TR = Return Air Temperature
TROOM = Room Air Temperature
: MULTI V, MULTI V WATER, MULTI V S, SINGLE SPLIT Control Option
TE
1) Maximum connectable EEV capacity for PAHCMR000, PAHCMC000 is 112 kW
SINGLE SPLIT
MULTI V WATER IV MULTI V S SINGLE SPLIT Centralized Controller 1)

AHU DX Coil

TR

OR / AND
DIVERSE OPTIONS FOR CONTROL
AHU communication kit can be connected to various LG Controller DDC by Contact signal DDC by Modbus ROOM
control systems such as LG individual/central controller
and DDC 1). It can be directly connected to DDC
without separated controller, so DDC can receive TROOM PAHCMR000
DDC

SOLUTION
CONTROL
Central Individual (Modbus or Contact signal)
product control and monitor information through OR
Controller Controller DDC DDC
contact signal or Modbus protocol.
AI / DI / DO
signal PAHCMC000
• LG Individual/Central controller supported
- LG controller stand alone or combination with DDC Single Split + Discharge Air Temperature Control
• Direct wiring between DDC and AHU communication kit
- Embedded Digital I/O and Analog Input Temp. Sensors
- Modbus RTU protocol supported AHU Kit AHU Kit AHU Kit Comm. Line
Central Comm. Line to ODU
1) DDC : Direct Digital Controller
Ref. Pipe

TE = Evaporator Temperature
(Liquid Pipe / Gas Pipe)
TD = Discharge Air Temperature
TROOM = Room Air Temperature

EXPANDABLE SYSTEM DESIGN Control Option


TE
LG AHU system can be a suitable solution for
various sites due to its application flexibility and SINGLE SPLIT
Centralized Controller 1)
TD
wide range of line up with large capacity models.
AHU DX Coil
According to the required capacity, a single or multiple
module combination is possible due to the AHU
communication kit's modular design.
Discharge Air control Return Air control Return Air control Return Air control OR / AND
• Multiple module combination for large capacity AHU
ROOM

TROOM PAHCMS000
DDC
OR (Modbus or Contact signal 2))

PAHCMM000 PAHCMC000
1) PI485 (PMNFP14A1) is required for centralized controller
2) In case of applying DDC with contact signal, discharge air temperature should be measured and controlled by DDC
Note : For more detail, please refer to the PDB

222 / 223
INTEGRATION DEVICE

AHU KITS
Multi V Application (Communication Kit & Controller Module)
Multi V + EEV Kit + IDU + Return / Room Air Temperature Control Multi V + EEV Kit + Discharge Air Temperature Control

Temp. Sensors Temp. Sensors


Comm. Line Comm. Line
Central Comm. Line to ODU Central Comm. Line to ODU
Ref. Pipe Ref. Pipe
TE = Evaporator Temperature Comm. Line between modules
(Liquid Pipe / Gas Pipe) TE = Evaporator Temperature
TR = Return Air Temperature (Liquid Pipe / Gas Pipe)
TROOM = Room Air Temperature TD = Discharge Air Temperature
TROOM = Room Air Temperature

EEV Kit 1) MULTI V

Control Option
TE
Control Option
MULTI V
Centralized Controller TE
AHU DX Coil
TD Centralized Controller

SOLUTION
AHU DX Coil

CONTROL
TR

OR / AND

OR / AND
ROOM

ROOM

TROOM PAHCMR000
DDC
(Modbus or Contact signal)
OR
TROOM PAHCMS000
DDC
OR (Modbus or Contact signal 2))
PAHCMC000 +

PAHCMM000 PAHCMC000

1) Multiple EEV kits can be applicable with multiple DX Coils and PAHCMR000s 1) Multiple EEV kits can be applicable with multiple DX Coils and PAHCMR000s
2) In case of applying DDC with contact signal, discharge air temperature should be measured and controlled by DDC 2) In case of applying DDC with contact signal, discharge air temperature should be measured and controlled by DDC
Note : For more detail, please refer to the PDB Note : For more detail, please refer to the PDB

224 / 225
INTEGRATION DEVICE

AHU KITS
Communication Kit Function Communication Kit Function
Communication with DDC via Contact Signal With LG Control system (Individual & Centralized Controller)
PAHCMS000 PAHCMS000
PAHCMR000 PAHCMR000
Function List (PAHCMM000 + Type Note Function List (PAHCMM000 Note
(PAHCMC000) (PAHCMC000)
PAHCMC000) +PAHCMC000)
Operation On/Off On/Off On/Off Digital Input (Non Voltage) - Operation On/Off On/Off On/Off -
Available operation mode can vary depending on Available operation mode can vary depending on
Operation Mode Cooling/Heating Cooling/Heating Digital Input (Non Voltage) Operation Mode Cooling/Heating/Fan Cooling/Heating/Fan
the settings of Communication Kit the settings of Communication Kit
Return (Room) Air Temperature2) 16 ~ 30 ℃ - Analog Input (DC 0~10 V/ 20mA) - Return (Room) Air Temperature2) 16 ~ 30 ℃ - -
Control1)
Discharge air temperature should be controller Standard II : 16 ~ 30 ℃
Control1) Discharge Air Temperature 2) - - -
directly by DDC using 'ODU Capacity Control Discharge Air Temperature2) - 12 ~ 50 ℃ Standard III : 12 ~ 50 ℃ (Available in April, 2020)
Central Controllers : 12~50℃
Fan Speed3) - High / Middle / Low Digital Input (Non Voltage) -
To control the AHU fan, dip switch 1-3 'DO type' should be
Forced Thermal On / Off - Digital Input (Non Voltage) - Fan Speed3) High/Mid/Low High/Mid/Low
set 'On(Fan Speed)' (PAHCMR000)
ODU Capacity - 40 ~ 100% Analog Input (DC 0~10 V/ 20mA) -
Operation On/Off On/Off -
Emergency Stop - Stop / Normal Digital Input (Non Voltage) -
Operation Mode Cooling/Heating/Fan Cooling/Heating/Fan -
Digital Output For PACHMR000, dip sw1-3 DO Type should be ○ ○
Return (Room) Air Temperature -
Operation On / Off On / Off (Max : DC 30 V / 1 A, set 'Off' (Status), In this case, 'fan speed' cannot
AC 250V / 1 A ) monitored by DO ports Discharge Air Temperature ○ -
Monitor
Operation Mode - - It needs to be checked through control signal Fan Speed High/Middle/Low High/Middle/Low -
Digital Output For PACHMR000, dip sw1-3 DO Type should be Defrost Operation On/Off On/Off Only with Individual Controller
Fan Speed High / Middle / Low High / Middle / Low (Max : DC 30 V / 1 A, set 'On' (Fan Mode) In this case, ‘On/Off, defrost,
AC 250V / 1 A ) error Status' cannot monitored by DO ports Error Alram Error Code Error Code Error code will be displayed on the screen

Digital Output For PACHMR000, dip sw1-3 DO Type should be Compressor On/Off On/Off On/Off Only with Individual Controller
Monitor
Defrost Operation Defrost / Normal Defrost / Normal (Max : DC 30 V / 1 A, set ‘Off' (Status), In this case, 'fan speed' cannot
AC 250V / 1 A ) monitored by DO ports ※ ○ : Applied, - : Not Applied
1) Control functions for LG individual and central controller are not available in case of using together with DDC via contact signal
Digital Output, Relay C contact For PACHMR000, dip sw1-3 DO Type should be 2) The range of setting temperature is different depending on the type of the controllers. And operation may different from setting range.
Error Alram Error/Normal Error/Normal (Max : DC 30 V / 1 A, set 'Off' (Status), In this case, 'fan speed' cannot 3) To control fan speeds, DO port of the fan speed status should be connected to the fan control panel
AC 250V / 1 A ) monitored by DO ports Note : For more detail information, please refer to the product data book

SOLUTION
CONTROL
Digital Output,
Compressor On/Off - On / Off (Max : DC 30 V / 1 A, -
AC 250V / 1 A )

1) Control functions for LG individual and central controller are not available in case of using together with DDC via contact signal
2) The range of temp. is differ depending on the type of the controller. Compatibility with LG HVAC Controllers
3) To control fan speeds, DO port of the fan speed status should be connected to the fan control panel
Note : For more detail information, please refer to the product data book BMS
Individual Controller Centralized Controller PDI
Gateway
AC Premium
Premium Standard III Standard II AC Ez AC Ez Touch AC Smart 5 ACP 5 Manager 5 1) ACP Lonworks Standard
Controller
Communication with DDC via Modbus protocol
PAHCMS000
PAHCMR000
Function List (PAHCMM000 Note
(PAHCMC000) +PAHCMC000)
PREMTA000
Operation On/Off On / Off On / Off PREMTB100 PQNUD1S40
Model no. PREMTA000A PREMTB001 PQCSZ250S0 PACEZA000 PACS5A000 PACP5A000 PACM5A000 PLNWKB000
PREMTBB10 PPWRDB000
Operation Mode Cooling / Heating / Fan Cooling / Heating / Fan PREMTA000B
Return (Room) Air Temperature 16 ~ 30 ℃ - PAHCMR000 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Discharge Air Temperature2) - 12 ~ 50 ℃ Dip SW1-2 Discharge Temp. Control Type should be set 'On' PAHCMS000 - ○2) ○ - - ○ ○ ○ - -
Control1)
Fan Speed3) High / Middle / Low -
※ ○ : Applied, - : Not Applied
Forced Thermal On/Off - - 1) AC Manager 5 is an integrator, so the installation with AC Smart 5 or ACP 5 is required
ODU Capacity Control2) - 40 ~ 100% Dip SW1-2 Discharge Temp. Control Type should be set 'On' 2) Set temperature range of this model shall be extended April, 2020
Note : 1. Dry contact for indoor unit (PDRYCB000 / 400 / 300 / 500) is not applied
Emergency Stop - - 2. For more details, please refer to the product data book
Operation On / Off On / Off
Operation Mode Cooling / Heating / Fan Cooling / Heating / Fan
Return(Room) Air Temperature ○ - Corresponding air temperature sensor connected to AHU
Discharge Air Temperature - ○ Comm. Kit is required
Monitor
Fan Speed High / Middle / Low High / Middle / Low
Defrost Operation Defrost/Normal Defrost/Normal
Error Alram Error / Normal, Error code Error / Normal, Error code
Compressor On/Off On / Off On / Off

※ ○ : Applied, - : Not Applied


1) Control functions for LG individual and central controller are not available in case of using together with DDC via contact signal
2) In case of PAHCMS000, control type between “Discharge Air Temperature” and “ODU Capacity Control” is selectable
3) To control fan speeds, DO port of the fan speed status should be connected to the fan control panel
Note : For the Modbus memory map and more detail information, please refer to the product data book

226 / 227
INTEGRATION DEVICE

AHU KITS
Outdoor Unit Compatibility Control Kit
For Small Size Application (~ 15kW) - Single Split List Required Item
Heating / Cooling SA / RA temperature sensor (or SA / RA temperature & humidity sensor)
UUA1 UUB1 UUC1 UUD1 / UUD3 Automatic Ventilation SA / RA temperature, CO2 sensor, Damper actuator (OA, EA, MA)
Type Model (2.5 ~ 5.0 kW)1) (5.0 ~ 8.0 kW)1) (7.1 ~ 10.0 kW)1) (10.0 ~ 15.0 kW)1)
Energy Saving (Cooling Mode Only) SA temperature, OA / RA temp&humidity sensor, Damper actuator (OA, EA, MA)
PAHCMR000 Humidification SA temperature, RA temperature & humidity sensor, Humidifier
- ○ ○ ○
Communication Kit (PAHCMC000) Inverter Fan Control SA / RA temperature, Static pressure sensor, Inverter driver for fan control
(Controller Module) PAHCMS000
- ○ ○ ○ Filter Alarm Difference pressure sensor
(PAHCMM000 + PAHCMC000)
Smoke Detecting Smoke detection sensor
Control Kit PAHCNM000 - - - -
RA : Return Air, EA : Exhaust Air, OA : Outdoor Air, SA : Supply Air, MA : Mix air (RA + OA)

Field Supplied Item


For Medium-Large Size Application (~ 672 kW) - MULTI V List Required Specification Apply Location
- Power : AC 24V, Output signal : DC 0 ~ 10V
MULTI V MULTI V WATER Temperature Sensor - Apply to MA, SA, RA
- Temperature boundary : -50 ~ 50°C
Type Model
5 Ⅳ Ⅲ S Ⅳ Ⅱ - Power : AC 24V, Output signal : DC 0 ~ 10V
- Apply to SA, RA, OA
Temperature & Humidity Sensor - Temperature boundary : -40 ~ 70°C
PAHCMR000 - Can not be applied to MA
○ ○ ○ ○ ○ ○ - Humidity boundary : 0 ~ 95% RH
Communication Kit (PAHCMC000)
- Power : AC 24V, In/Output signal : DC 0 ~ 10V
(Controller Module) Damper Actuator - Apply to OA, EA, MA damper
PAHCMS000 - Rotation angle : 90°
○ ○ ○ ○ ○ ○
(PAHCMM000 + PAHCMC000) - Power : AC 24V, Output signal : DC 0 ~ 10V
Difference Pressure Sensor (for Filter) * Boundary : 0 ~ 1000Pa - Apply to filter
Control Kit PAHCNM000 ○ ○ ○ ○ ○ ○
- Switch type : Relay Open / Close
- Power : AC 24V, Output signal : DC 0 ~ 10V
Static Pressure Sensor - Apply to SA (for inverter control)

SOLUTION
CONTROL
- Boundary : 0 ~ 1000pa
- Power : AC 24V, Output signal : DC 0 ~ 10V
CO2 Sensor - Apply to RA duct
- Boundary : 0 ~ 2000ppm
Smoke Detection Sensor - Power : AC 24V, From : Contact point type - Apply to RA duct

Expansion Application Kit Compatibility

Control Application Kit


Capacity index (kW) Connection by ODU system
(Maximum connectable EEV Kits)
EEV Kit
Model PAHCMS000 MULTI V
PAHCMR000
Min. Max. (PAHCMC000) (PAHCMM000 + PAHCNM000 Single Split
PAHCMC000) Heat Pump Heat Recovery

PRLK048A0 3.6 28 ○ (1) ○ (1) ○ (6) ○ ○ - Various Control with Control kit – Multiple MULTI V + EEV Kits

PRLK096A0 28.1 56 ○ (1) ○ (1) ○ (6) ○ -
(Max 33.7 kW)
Air handling unit (3rd party)
PRLK396A0 56.1 112 ○ (1) ○ (1) ○ (6) ○ - - MULTI V (ODU)
EA OA EEV Kit
RA SA
PRLK594A0 112.1 168 - ○ (1) ○ (3) ○ - - Temperature Sensor
- Return Air, Supply Air (Essential)
※ O : Applied, - : Not applied - Mixed Air
Note 1. Table of the outdoor unit compatibility is based on European regional model.
2. When connecting outdoor units in other areas, please check whether they are compatible or not. Temp & Humidity Sensor
3. Expansion application kit compatibility is based on capacity index of the system, it may changed according to system design condition. - Return Air / Supply Air / Outdoor Air EEV Kit
MULTI V (ODU)
Damper Actuator
- Exhaust Air / Outdoor Air / Mixed Air

Differential Pressure Switch

Valve for Humidifier


Control Kit

CO2 Sensor

Smoke Detector

Fan
- Supply / Return

Connection Pipe
Communication line
Thermistor (Pipe Temp.)
Signal
AHU HMI

228 / 229
APPLICATION

HOTEL SHOPPING MALL


Hotel Control Solution Shopping Mall Control Solution

Guest Rooms Retail


Air conditioner automatically switches Proportionally distribute and manage
off when guests depart the power consumption by tenants
Dry contact PDI

Integrated control of air conditioner Real-time system issue detection


with the hotel room controller and alert Central controller
Dry contact (Operation trend)

Air conditioner can be controlled with


existing hotel thermostat Dry contact Maintenance Office
For thermostat

Reduces energy by checking


Prioritizes guest safety with refrigerant operational trends Central controller
(Operation trend)
leak detection Refrigerant
Leak detector

Reception Atrium
Integrated management of AHU applied
Air conditioner control in conjunction
to large spaces
with check-in or check out AC Smart 5 Comm. Kit
(Schedule)

Public Areas Chiller and VRF integrated control

SOLUTION
CONTROL
Central controller
Centralized management of the public areas (Operation trend) Chiller option kit

Design Proposal Design Proposal


Guest Room Lobby Retail Maintenance Office Atrium

The air conditioner Integrated control of Control with existing Guest safety is Air conditioner control Proportionally distribute Fast problem detection Reduces energy Integrated Chiller and VRF
automatically turns off air conditioner with the hotel thermostat the first priority in conjunction with and manage power and alarms by checking management of AHU integrated control
when guests leave hotel room controller check-in or check out consumption by the tenant operational trends applied to large spaces
WHM
(Watt-Hour Meter) Chiller option
Error C store
Pulse signal kit (S/W)
Over
24°C Cooling

21°C
ACP 5

Power PDI
100 kWh

PDRYCB400 PDRYCB500 PDRYCB300 PRLDNVS0 PACS5A000 PPWRDB000 PACS5A000 PAHCMR000 PCHLLN000


2 contact point Modbus RTU(9,600bps) NEW PDRYCB320* Refrigerant leakage detector AC Smart 5 PDI Standard (2 port) AC Smart 5 AHU Comm. Kit Chiller option kit
8 contact point
Input Function • 6000ppm • BMS Integration • Max. 128 IDU • BMS Integration • Return air
• Operation On / Off • Operation Input (BACnet IP, Modbus TCP) (BACnet IP, Modbus TCP)
• Indoor temperature • Universal Input*
Output • Error alarm • Operation On / Off
• Operation On / Off status • Set run mode • Thermo On / Off PACP5A000 PACS5A000
• Error alarm • Set temperature • Operation mode ACP 5 AC Smart 5
• Set fan speed (Fan / Heat / Cool)
• Fan speed
(Low / Middle / High)
PREMTB100 PACP5A000 PQNUD1S40 PACP5A000 PAHCMS000
Wired remote controller ACP 5 PDI Premium (8 port) ACP 5 AHU Comm. Kit
Output
• Operation On / Off status • 4.3 inch color LCD • BMS Integration • Max. 128 IDU • BMS Integration • Discharge air
• Error alarm • Touch button (BACnet IP, Modbus TCP) (BACnet IP, Modbus TCP)

* Available from April 2020

230 / 231
APPLICATION

HOSPITAL ACADEMIC INSTITUTION


Hospital Control Solution Academic Institution Control Solution

Hospital Ward Classroom


Automatically save energy in the
Proper airflow management for patients absence of students Wired remote
Wired remote controller
controller

Central controls prevent students from


Monitor the comfort level for each
arbitrary control
hospital ward Central controller
Central controller
(Lock)
(Comport level)

Lecture Hall
Control fan speed and air volume
Dry contact
Schedule management according to
academic plan Central controller
(Schedule)

Service Zone
Energy savings based on flexible Maintenance Office
scheduling Central controller Integrated management of distributed
(Schedule)
buildings Central controller
(Multiple management)

Lobby
Centralized management of AHU for Centralized management with multiple
large spaces interfaces Central controller

SOLUTION
CONTROL
(HTML5)
Comm. Kit

Design Proposal Design Proposal


Hospital Ward Service Zone Lobby Class Room Lecture Room Maintenance Office

Proper airflow Monitor the comfort level External device Energy savings based on Centralized management Automatically save Central controls Schedule management Integrated management Centralized management
management for patients for each hospital ward interlock control flexible scheduling of AHU for large space energy in the absence prevent students from according to academic plan of distributed buildings with multiple interfaces
of students arbitrary control

Relay

PTVSMA0 PACS5A000 PDRYCB400 PACS5A000 PAHCMR000 PTVSMA0


Human detection sensor AC Smart 5 2 contact point AC Smart 5 AHU Comm. Kit Human detection sensor

• BMS Integration Input • BMS Integration • Return air


(BACnet IP, Modbus TCP) • Operation On / Off (BACnet IP, Modbus TCP)

Output PACS5A000 PACP5A000 PACM5A000


• Operation On / Off status AC Smart 5 ACP 5 AC Manager 5
• Error alarm
• BMS Integration • BMS Integration
(BACnet IP, Modbus TCP) (BACnet IP, Modbus TCP)
PREMTB100 PACP5A000 PACP5A000 PAHCMS000 PREMTB100
Wired remote controller ACP 5 ACP 5 AHU Comm. Kit Wired remote controller

• 4.3 inch color LCD • BMS Integration • BMS Integration • Discharge air • 4.3 inch color LCD
• Touch button (BACnet IP, Modbus TCP) (BACnet IP, Modbus TCP) • Touch button

232 / 233
APPLICATION

OFFICE RESIDENTIAL
Office Control Solution Residential Control Solution

Maintenance 0ffice
Energy savings and management
throughout the building Central controller
Home
(Energy Navi.)
Anytime, anywhere air conditioner
control and access
Integrated management of HVAC with Wi-Fi Modem

BMS system Central controller


(BMS Gateway)
Integrate systems
for smart connectivity throughout
Modbus RTU
Reduce costs by replacing BMS
Central controller
(Operation trend) ACS IO Module

Office Room Bed Room


Reasonable power distribution to
Use a familiar residential thermostat
tenants Dry contact
PDI For thermostat

Server Room Simple interlocking control by remote


control Wired remote
controller
24-hour backup management
Central controller
(Backup operation)
Apartment / Residence
Meeting Room

SOLUTION
Stable system operation

CONTROL
Independent
Energy savings based on occupancy power module

detection Wired remote


controller

Design Proposal Design Proposal


Maintenance Office Office Room Server Room Meeting Room Home Bed Room Apartment

Energy savings Integrated Reduce costs by Reasonable power Main equipment Energy savings Control your home air Build a Smart house Use a familiar residential Simple interlocking Stable system
and management management of HVAC replacing BMS distribution to tenants 24 hours back up based on occupancy conditioner anytime, thermostat control by remote control operation when indoor
throughout the building with BMS system management detection anywhere unit power is lost

WHM Human
BMS Protocol Pump Lighting Fan Sensor (Watt-Hour Meter) detection
Pulse signal sensor

Target Error Lighting

Power PDI A B
Fan
BMS System 100 kWh
Forecasting

Radiator

PACS5A000 PLNWKB000 PEXPMB000 PPWRDB000 PACS5A000 PTVSMA0 PWFMDD200 PDRYCB500 PDRYCB300 PREMTB100 PRIP0
AC Smart 5 LonWorks gateway ACS IO Module PDI Standard (2 port) AC Smart 5 Human detection sensor LG Wi-Fi modem Modbus RTU (9,600bps) NEW PDRYCB320* Wired remote controller Independent power module
8 contact point
• BMS Integration • Max. 128 IDU • BMS Integration Function Function • 4.3 inch color LCD • EEV full close function
(BACnet IP, Modbus TCP) (BACnet IP, Modbus TCP) • On / Off • Operation Input • Touch button
• Fan speed • Indoor temperature • Universal Input*
• Operation mode • Error alarm • Operation On / Off
• Vane control • Set operation mode • Thermo On / Off
• Reservation • Set temperature • Operation mode
(Sleep, Weekly On / Off) • Set fan speed (Fan / Heat / Cool)
• Error check • Fan speed
PACP5A000 PMBUSB00A PEXPM300 PQNUD1S40 PACP5A000 PREMTB100 (Low / Middle / High)
ACP 5 Modbus RTU gateway PEXPM200 PDI Premium (8 port) ACP 5 Wired remote controller
PEXPM100 Output
• BMS Integration • Max. 128 IDU • BMS Integration • 4.3 inch color LCD • Operation On / Off status
ACU IO Module
(BACnet IP, Modbus TCP) (BACnet IP, Modbus TCP) • Touch button • Error alarm
* Available from April 2020

234 / 235
ACCESSORIES

MECHANICAL ACCESSORIES / PIPING ACCESSORIES

ACCESSORIES
236 / 237
MECHANICAL ACCESSORIES

CASSETTE PANEL DUAL VANE CASSETTE PANEL


The Independent Vane Operation makes desired and comfortable air flow. Model Name
PT-AAGW0
Model Name & Applied Products PT-AEGW0
4 Way Cassette PT-AFGW0
PT-MCHW0
PT-QCHW0
PT-UQC / PT-UMC1
2 Way Cassette Key Features
PT-QCHW0, PT-MCHW0 PT-UQC, PT-UMC1 PT-USC
PT-USC Function
1 Way Cassette (Grill Type) Model
Dual Vane Wi-Fi Floor Temperature Air Purification Elevating Grille Occupancy Sensor
Sensor
PT-UUC / PT-UUC1 / PT-UTC
O Optional X X X Optional
PT-AAGW0
1 way cassette (Panel Type) PT-AEGW0 O Optional X X O Optional
PT-UUD / PT-UTD PT-AFGW0
O Optional O Optional X Optional

PT-UUC, PT-UUC-1, PT-UTC PT-UUD, PT-UTD


Specification
Key Features Model Suction
Type
Color
(RAL) Gloss Weight
(kg)
Dimension (mm)
W H D
• Independent vane operation uses separate motors, making it Possible to control all 1, 2, and 4 vanes independently. Grid White (RAL 9003) - 7.1 950 35 950
PT-AAGW0
• The detachable corner design makes it easy to adjust the hanger during installation and to check for leakages in the drain PT-AEGW0 Grid White (RAL 9003) - 8.5 950 35 950
PT-AFGW0
pipe and refrigerant pipes. Grid White (RAL 9003) - 7.5 950 35 950

Air Purification Kit


Dielectric Photocatalytic
Dust collecting Deodorizing HVPS Ionizer
Compact and Stylish Design Model Image Model name
filter filter

• New 4 way cassette panel adapted unibody shape and matching with into the ceiling
Cassette cover installation manual
• Panel size is fit into the ceiling tile

ACCESSORIES
Follow the details to install the external cover correctly.
• Read the installation manual carefully before installing the cover.
• To prevent the exterior of the cover from being scratched or become dirty during the
Air cleaning kit assembly, always put a clean sheet on the floor.
PTAHMP0 O O O O
• Always use the screw included in the product. This product is composed of the following components.
(If you use other screws, it can damage the product.)
Unibody
The purpose of this external cover is to prevent the
Shape indoor unit from being exposed externally.
(No Inlet Line) Cassette cover installation manual
• Use this when install the cassette air conditioner on the ceiling without any finishing.

Ceiling Ceiling
8mm
8mm
Indoor unit Indoor unit 266mm
308mm

TM model TN model Follow the details to install the external cover correctly.
Ceiling • Read the installation manual carefully before installing the cover.

CASSETTE COVER • To prevent the exterior of the cover from being scratched or become dirty during the
50mm
266mm assembly, always put a clean sheet on the floor.
This product is composed of the followin
Indoor unit
• Always use the screw included in the product.
TP model (If you use other screws, it can damage the product.)

Cover in case of exposed cassette installation. Cassette


The characteristics of this external cover are as follows.cover installation manual
The purpose of this external cover is to prevent the
1. The height of the cover can be adjusted according to the height of the product.
(Refer to top picture)
2. Cover on the piping side can be detached. indoor unit from being exposed externally.
Follow the details to install the external cover
• Use this when correctly.
install
Model Name
the cassette air conditioner on the ceiling without any finishing.
• Read the installation manual carefully before installing the cover.
• To prevent the exterior of the cover from being scratched or becomeCeiling
dirty during the
PTDCM / PTDCQ 8mm
Ceiling
assembly, always put a clean sheet on the floor. 8mm
• Always use the screw included in the product.
Indoor unit 308mm This product
Indoor unit
is composed
266mm
of the following components.
(If you use other screws, it can damage the product.)

Cassette
Cassette Thecover cover
purpose installation
of thisinstallation
external cover manual
ismanual
Applied Products
Detach function

to prevent the
TM model

Ceiling
TN model

Specification Cassette
Cassette
indoor unit from being exposed externally.
• Usecover cover
this when installation
installation
install the cassette manual
air conditioner on manual
the ceiling without any finishing.
50mm
4 Way Cassette (for chassis TP, TN, TM, TQ, TR)
Indoor unit
266mm

Follow the details to install the external cover correctly.


Follow the details to install the external cover correctly. P/No.:3828A20128R

Suction Color
Dimension (mm) Applied Model Capacity (kW)* Key Features • Read the installation manual carefully before installing the cover.
• Read the installation manual carefully before installing
• To prevent the exterior of the cover from 8mm
the cover.
Ceiling
being scratched or become dirty during the
TPCeiling
model

Included Parts
Gloss Weight Follow the details to install thescratched
external cover dirtycorrectly.
8mm

Model Follow
assembly,the
• To prevent
always details
the exterior
put a clean tosheet
ofinstall
the
on thethe
cover
floor. external cover correctly.
from being or become during the
The characteristics of this
266mm external cover are as follows.
Single Split MULTI Split MULTI V assembly, always put a clean sheet on the floor. Indoor unit Indoor unit
This product is composed of the offollowing components.
308mm
Type (RAL) (kg) W H D •
Read the
• Always Read
use the installation
installation
the screwmanual
included manual
carefully carefully before installing
before installing the cover.
in the product. the cover. This
cover product is according
composed the
of thefollowing components.
R32 R410A R32 R410A R410A • Specially designed for indoor unit
• (If
To you
• Always use the screw included in the product.
• use
To you
prevent other
prevent
theuse screws, itthe
the exterior
exterior can
ofscrews, ofdamage
coveritthe
the
cover
from product.)
from
being being scratched
scratched ormodel or become
become dirty the
dirty during during the
1. The height of the
(Refer toTN
topmodel
picture)
can be adjusted to the height product.

assembly,
(If
assembly,
other
always always put asheet
put a clean cleanon
can damage
sheet
the
on the floor.
the floor.
TM
product.)
• Cover A, Cover B • Screws
PT-QCHW0 Grill Morning Fog (RAL 9001) - 3.0 620 35 620 2.5 ~ 5.0 2.5 ~ 5.0 1.5 ~ 5.3 1.5 ~ 5.3 1.6 ~ 6.2 • Covers the side area of cassette • Always use the screw included in the product. Ceiling This
product product
is is
2. Cover on the piping side can be detached.
This composed
composed of theof the
followingfollowing components.
components.
The purpose of this external
• Always use the screw included in the product.
(If youThe purpose it of
can this
it canexternal cover is to is
cover prevent
to prevent the the
(If you
use usescrews,
other other screws, damage damage the product.)
the product.)
50mm • Cover C, Cover D • Installation Manual
4 Way
PT-MCHW0 Grill Morning Fog (RAL 9001) - 6.3 950 35 950 6.8 ~ 14.6 6.8 ~ 14.6 6.7 - 7.1 ~ 15.8
• Gives elegantindoor
looks unit from
indoor unit from beingbeingexposed exposed externally.
externally.
Indoor unit
266mm

PT-UQC Grill Morning Fog (RAL 9001) - 3.0 700 22 700 2.5 ~ 5.0 2.5 ~ 5.0 - 1.5 ~ 5.3 1.6 ~ 6.2 The The
purpose
• Use this purpose
when
• Use this when oftheexternal
ofinstall
this this
install the cassette external
cassette air cover
air conditioner on cover
the ceilingis
isonto
conditioner to prevent
theprevent
without
ceiling
any finishing.the
the
without any finishing.
• Light weightindoor indoor unit from
unitCeiling
from beingbeingexposed exposed externally.
externally.
TP model
Ceiling
PT-UQC Grill Morning Fog (RAL 9001) - 5.6 950 25 950 6.8 ~ 14.6 6.8 ~ 14.6 - 6.7 7.1 ~ 15.8 • Use thisinstallCeiling
whenthe
install the cassette air conditioner on the without
ceiling without
Ceiling
any finishing.
The characteristics of this external cover are as follows.
8mm
8mm• Use this when cassette air conditioner on the
8mmceiling any finishing.
8mm 266mm
Indoor unit 308mm Indoor unit 266mm
Indoor unit Indoor unit
2 Way PT-USC Grill Morning Fog (RAL 9001) - 4.7 1,100 28 690 - - - - 2.8 ~ 7.1 Ceiling Ceiling
308mm
1. The height of the cover canCeiling
Ceiling
be adjusted according to the height of the product.

PT-UUC Grill Noble White (RAL 9003) ○ 4.6 1,100 34 500 - - - - 2.2 ~ 3.6 Specification 8mm 8mm TM model
TMIndoor
model
Indoor unit unit 308mm
2.
(Refer to
8mm top picture)
8mm
TN model
Cover on the piping
308mm sideTN
Indoor can
unit
model
be unit
Indoor detached.266mm 266mm Detach function
Ceiling
Ceiling
PT-UUC1 Grill Noble White (RAL 9003) - 4.4 1,100 34 500 - - 2.6 ~ 3.5 2.6 ~ 3.5 - 50mm TM model
TM model TN model
TN model
50mm
Weight
266mm (kg) Dimensions (mm) Cover A (4 units) Cover B (4 units) Screw (32 units)
Indoor unitCeiling 266mm
1 Way PT-UTC Grill Noble White (RAL 9003) ○ 5.5 1,420 34 500 - - - - 5.6 ~ 7.1 Model Front Panel
Ceiling
Indoor unit
50mm 50mm
TP model
NET Gross W H D
PT-UUD Panel Noble White (RAL 9003) ○ 4.6 1,100 34 500 - - - - 2.2 ~ 3.6 TP model
Indoor unit
Indoor unit
266mm 266mm

TP / TN of this
The characteristics
PT-UMC / characteristics 5.9external 8.8cover1,157 are as 1,157
follows. 268
PT-UTD Panel Noble White (RAL 9003) ○ 5.5 1,420 34 500 - - - - 5.6 ~ 7.1 PTDCM The of this external cover are as follows.
PT-UMC1 theTP
1. The heightTPofmodel model
cover can be adjusted according to the height of the product.
1. The heightTMof the cover can 5.9 8.8 to the
be adjusted according 1,157
height of the1,157
product. 310
(Refer to top picture)
* Based on cooling capacity The The
2. Cover
characteristics
characteristics
on the piping side can of
(Refer to top picture) of external
this this external
be detached. covercover are
are as as follows.
follows. Detach function
2. Cover on the piping side can be detached.
TR 5.0 7.2 907 907 268
※ ○ : Applied, - : Not applied 1. Theof
1. The height height of thecan
the cover cover
be can be adjusted
adjusted according
according to theof
to the height height of the product.
the product.
PTDCQ PT-UQC (Refer
(Refer to to top picture)
top picture)
2.on
2. Cover Cover
the pipingTQ
on theside
piping
canside
be can 5.0
be detached.
detached. 7.2 907 907 310 Cover C (4 units) Cover D (4 units) Installation Manual
P/No.:3828A20128R

238 / 239

Detach function
Detach function
MECHANICAL ACCESSORIES

CO2 SENSOR REFRIGERANT LEAKAGE DETECTOR


CO2 sensor in ventilation system. R410A refrigerant leakage detector ensures room safety.

Model Name Model Name


AHCS100H0 PRLDNVS0

Applied products Applied Products


LZ-H025GBA4 MULTI V 5
LZ-H035GBA5 / LZ-H050GBA5 MULTI V IV Heat Pump & Heat Recovery
LZ-H080GBA5 / LZ-H100GBA5 MULTI V WATER IV
LZ-H150GBA5 / LZ-H200GBA5

Applicable products Key Features Specification


LZ-H050GXN0 / LZ-H080GXN0 •T  his detector senses refrigerant leakage when the Parts Specification

LZ-H100GXN0 / LZ-H050GXH0 refrigerant concentration exceeds 6,000ppm. Rated Voltage (V) DC 5.0 5%
Dimensions (W x H x D, mm) 31 x 44 x 20
LZ-H080GXH0 / LZ-H100GXH0 (The green and red LED lights blink simultaneously.) Weight (g) 22
• Alarm is “on” when refrigerant leaks out more than Detectable Refrigerant R410A
Sensor
6,000ppm for 5 seconds. If it is reduced less than Detected Concentration (ppm) 0 / 6,000 Alarm Off / On
Key Features 6,000ppm for 5 seconds, alarm is “off”.
Operating Temperature Range (oC) -10 ~ 50
Preserved Temperature Range (oC) -40 ~ 60
Specification Dimensions (unit : mm) • When the alarm of the refrigerant leak detector is switched Average Power Consumption (mA) 35
Connecting
• Applied Model : ERV (Embeded), ERV DX (Option) 69 26.4 on the user must ventilate the room until the alarm is Cable Cable Length (m) 10
Sensor Dimensions of Front Plate (W x H x D, mm) 80 x 110 x 44.6
• Supply voltage : DV12V 5% disabled. Protective
Cover Dimension of Backplate (W x H x D, mm) 80 x 110 x 6.5
• Output : 0.6 ~ 4.4V (Linear output, 240 ~ 1,760 ppm CO2) • The detector has to be installed inside the room and it shuld This function available for ARU****L**5 and 4(Multi V 5, Multi V IV H/P, H/R model)
• Accuracy : 10% (2 days after installation)
50

be installed 300 ~ 500mm above the floor.


Description
• The product is especially designed to detect CO2
Included Parts
• This model requires Standard III Wired Remote Controller for display

ACCESSORIES
Key Application
CO2 (ppm)

Sensor Connecting Cable Sensor Protective Cover


Windows Windows Windows Windows
Closed Open Closed Open
2,500

CO2 Sensor (AHCS100H0)


Without ERV Key Application
Embedded inside of ERV With ERV
1,000 Refrigerant Leakage Detector has three application methods.
Standard III Wired
Remote Controller 0
ERV with CO2 Concentration Control Case 1) Case 2) Case 3)
Time (min) Stop Operating Main Pipe Closing & Branch Pipe Closing &
(System Termination) Pump Down Continuous Operating

How to Intstall
1. R
 emove a screw on the service cover. Pull the service cover fixing bracket(①), then remove the service cover(②). Remove two elements(③) and two air filters(④). Room 1 Room 2 Room 1 Room 2 Room 1 Room 2

2. Install the sensor with two screws.


3. Remove a screw, then remove the right side of element rail(⑤).
 ress the holder(⑥) into the hole to fix the CO2 sensor cable(⑦).
4. P
5. Connect the wire terminal to the CN-CO2 port of PCB. Room 3 Room 4 Room 3 Room 4 Room 3 Room 4

※ Airflow can be controlled by concentration of CO2, after setting automatic operation mode at remote controller.
※ Use the screwdriver whose total length is less than 250mm. Accessory Specification (To realize the case 2 application)

Screw1 Screw2 [Optional / Field Supply]


I/O Module PRLDNVS0 [Optional / Field Supply] PDRYCB400 Buzzer alarm [Field Supply] Central Control Devices
PVDSMN000 (Refrigerant Automatic (Dry contact) for central control room Buzzer alarm for room
leak detector) Ball Valve1) (Direct connection ~ DC 30V, ~ 1A)
Screw
※ Necessary accessory 1) Please contact to subsidiary to get
1 2 3 4 5 6 the recommended specification.
(LG Electronic don’t provide this accessory)

240 / 241
MECHANICAL ACCESSORIES

EEV KIT (FOR INDOOR UNIT) IR RECEIVER


MULTI V EEV KIT is specially designed to reduce noise and make comfort environment. IR RECEIVER can be connected to ceiling concealed duct and floor standing unit which the customer wants to control
by wireless remote controller.
Model Name Model Name
PRGK024A0 PWLRVN000

Applied Products
Applied Products
Indoor Unt Model Chassis Applicable
1 Way Cassette TU ○ MULTI V Indoors (Ceiling Concealed Duct, Floor Standing Units)
TT N/A
2 Way Cassette
TS ○(~5.6kW)
Cassette TR ○
TQ ○(~4.5kW)
Key Features 4 Way Cassette TP
TN
N/A
N/A
Key Features
TM -
• Decreasing noise level of Multi V Indoor units and easy BG - •D  esigned for wireless control
High Sensible BR -
installation B8 -
• Indication lamps (3 colors) and Self-diagnosis function
High Static B8 -
Duct M1 ○(~5.6kW)
Middle Static M2 -
M3 -

Low Static
L1
L2

-
Key Application
L3 -
Floor Standing
CE ○ Note : D
 o not install both the IR Receiver and Wired Remote Controller. This may cause malfunctions.
CF -
Convertible VE ○
V1 -
Ceiling Suspended
V2 -
SJ ○
Etc Wall Mounted SK ○
SV -
Art Cool SF ○
Console QA ○
K2 -
HYDRO KIT
K3 -

Key Application ※ ○ : Applied, - : Not applied, N/A : Not Applicable Wired Remote
Controller IR Receiver

EEV Kit can be applied for the space which requires quiet

ACCESSORIES
Pipe
Wire environment and noise sensitive space.
Refrigerant flow (Cooling)
Refrigerant flow (Heating)
Outdoor Unit Wireless Remote
Controller
(Standard)
C / Box EEV
Kit
Luxury Hotel Villa
Indoor Unit Operation of Indication Lamps Test Run Mode
① Emergency Operation button : After installing the product, you must run a
Turns the indoor unit on or off when Test Run mode. Press the Emergency Operation
Indoor Unit EEV Kit Outdoor Unit remote controller is not working. button for 5 seconds, until the LED flickers. Then
Indoor Heat Exchanger
Electronic ② Signal Detector : the indoor unit, duct runs cooling mode for 18
Expansion Valve minutes, where the setting temperature is 18℃
Fan M Receives the signal from remote controler.
③ Timer lamp (Green) : and the fan speed is high.
COMP
M Fan Heat Exchanger
Executive office Meeting room Lights up during the timer operation.
Note : If you don’t use EEV of same specification, Cooling (Heating) capacity could be decreased. ④ Hotstart lamp (Orange) :
Lights up during the pre-heating operation,
defrost operation as well as latent heat
6 5 removal operation in heat mode. Available
4 3 only for the heat pump models, not cooling
only models.
How to Install 2 1
⑤ System On/Off lamp (Red) :
Lights up during system controller
Open Indoor unit’s control box cover. Signal Receiver operation.
① Open fully indoor unit’s EEV through vacuum mode of ODU setting. Indoor Unit ⑥ Filter Sign lamp (Green) :
② Detach the Indoor unit’s EEV connector from PCB and then push the reset C/Box  Lights up after 2,400 hours from the time
button of Outdoor unit’s PCB
of first power on operation.
③ After connecting indoor unit’s EEV CONNECTOR, repeat the process Existing
① & ②. Then, connect the EEV CONNECTOR of EEV KIT in PCB of indoor unit. EEV
④ Finally connect the lead wire of the EEV Kit to the indoor unit’s PCB. KIT
EEV
⑤ Assemble the control box cover.
CN-EEV

242 / 243
MECHANICAL ACCESSORIES

INDEPENDENT POWER MODULE AUXILIARY HEATER RELAY KIT


It closes EEV in indoor unit when power cut.   Providing an efficient way to add auxiliary heat

Model Name Model Name


PRIP0 PRARS1
Applied Products
Applied Products Wall Mounted, Art Cool Mirror, Art Cool Gallery
MULTI V Indoor Units
Model Name
PRARH1
Key Features Applied Products
• Independent Power Module is specially designed to close the Indoor EEV when power cut-off.
1,2,4 Way Ceiling Cassette, High Static Ducted,
- Supply Voltage : DC 12V 50% Key Features Low Static Ducted, Ceiling Suspended
- Provides two stages of auxiliary heat for indoor unit
- Provides ability to use the two stage auxiliary heater as
IncludedIncluded
Items
Included
ItemsItems
the primary or secondary heating source
Included Parts Key Application
Model PRIP0 (Others) If the EEV is opened due to power cut off, liquid refrigerant
2. Included
2. 2.
IncludedItems
Included
Included Items
Items
Parts
Included Items
Key Application
Electrical Wiring

2. Included Items

ENGLISH

ENGLISH
ENGLISH
• Harness 1 (1m)
Item
Independent
Screw
Clamp
• Harness 2 (1m)
flows into compressor. It could damage the compressor in Model ModelModel Model PRARH1 PRARH1
PRARH1
PRARH1 3 rdParty Scope
3 rd
Party Scope
(Tie Wrap)

ENGLISH
Power Kit cooling mode. Also condensing might be happened for unclosed
• Harness 3 (1m) PRARH1
Item Auxliary
Item Heater
Item Auxliary Relay
Auxliary
Model
Heater
Item Kit
Heater
Relay Kit Screw
Relay
Auxliary Kit ScrewScrew
Heater Insulation
Screw InsulationInstallation
Insulation
Insulation Manual
Installation
Installation
Installation ManualManual
Q,ty 1 2 4 • Installation Manual EEV’s indoor unit due to flow of refrigerant. Q’ty Q ’ t y 1 Item 1
Relay Kit
Auxliary Heater 2
Relay Kit 2 2
Screw 2
Insulation
Manual
1Installation 1
• Insulation (PE) Q’ty 1 2 2 1 Manual RADIATOR
RADIATOR
Q’ty
Q'ty 11 2 2 2 2 1 1
IncludedIncluded Items Items
ItemsIncluded
Electricity Cut-off EEV Valve
Hot Water

2. Included Items
Close Hot Water

2. Included
2. Included
Figure FigureFigure
Items Items
Figure
Figure Included Items
Figure

ENGLISH
External Power supply

ENGLISH

ACCESSORIES
ENGLISH
2. Included Items
- Supply voltage : AC 24V
M4 x10
• PRARH1 applies to High Static Duct, Low Static Duct, 1Way CST, 2Way CST, 4Way CST and Ceiling
PRARS1 PRARS1

ENGLISH
Model ModelModel Suspended types.
Model PRARS1 PRARS1 LG Scope
LG Scope
• PRARH1 applies
• PRARH1 to
• PRARH1 High
applies Static
applies
to High Duct,
to HighLow
Static Static
Static
Duct, LowDuct,
Duct, Low1Way
Static Duct,CST,
Static 2Way
Duct,
1Way CST,CST,
1Way CST,4Way
2Way CST,CST
2Way CST,
4Way and Ceiling
4Way
CST CSTCeiling
and and Ceiling
Item
Item Suspended
Suspended Item
Auxliary
types. Auxliary
SuspendedHeater Heater
Auxliary
Relay Kit
Model
types.
types. Item Relay
Heater Kit
Relay
Auxliary Kit
Heater
Screw Screw PRARS1
Screw Insulation
Insulation
Screw Installation
Installation
Insulation
Installation
Insulation Manual Manual
Installation Manual Indoor Unit
Indoor Unit

Relay Kit Manual


Q’ty Q’ty Q’ty 1 Item 1 1 Heater Relay
Auxliary 2 Kit 2 2 2
Screw 2Insulation
2 1
Installation1(Unit
Manual 1
: inch)
Q’ty
Q'ty 11 22 2 2 1 1

(Unit : inch)
(Unit : (Unit
inch) : inch)
CN_PTC

DC12V
DC12V

How to Install Figure FigureFigure Figure Auxiliary Relay


Auxiliary Kit
Relay Kit
Figure

A
2-19/32

B
CN_PTC1

A
DUCT / FS / CVT / FAU CST / Console / Hydro Kit Gen2 Wall Mounted / ARTCOOL Gen4 Wall Mounted ① Turn the power off using circuit breaker.

B
② Disconnect the EEV cable of the indoor unitʼs PCB
CN_WRITE or CN1
CN_WRITE or CN1

(CN-EEV) • PRARS1 applies to Wall mounted and Art cool types.

2-19/32

2-19/32
③ Connect the independent power module (CN-EEV/

2-19/32
• PRARS1
• PRARS1 applies applies
• PRARS1
to to Walltomounted
Wallapplies
mounted Wall
and Art and Art
mounted
cool cool
and
types.Arttypes.
cool types. 7-9/32
CN_EEV
CN_EEV CN_EEV LOAD) to the indoor unitʼs EEV, using harness 1.
How to Install (Unit : inch)
CN_WRITE or CN1

CN_EEV Harness 2 1-13/32 6-23/32


CN_WRITE or CN1

Harness 2 EEV EEV


Harness 3
EEV ④ Connect the independent power module (CN-EEV/
EEV Harness 3 Harness 4
MAIN) to the indoor unitʼs PCB (CN-EEV/CN-
CN_EEV / MAIN CN_EEV / MAIN
CN_EEV / MAIN
(Unit : inch)
(Unit : inch) (Unit : inch)
CN_EEV / MAIN WRITE), using harness 2 or 3.
⑤ Supply the power. Model : PREMBTB100

3-13/32
7-9/32 14 Auxiliary Heater Relay Kit
7-9/32 7-9/32

2-19/32
CN_EEV / LOAD

2-7/32
CN_EEV / LOAD
CN_EEV / LOAD CN_EEV / LOAD

2 3/16
Harness 1 1-13/32 1-13/321-13/32 6-23/32 6-23/326-23/32

1-7/16
Harness 1 Harness 1 Harness 1
* FS : Floor Standing Aux heater
Aux heater communication
* CVT : Convertible communication lines Aux heater communication lines lines
To Indoor unit’s EEV
* FAU : Fresh Air Intake Unit

2 3/16
To Indoor unit’s EEV

2 3/16
To Indoor unit’s EEV To Indoor unit’s EEV
* CST : Cassette 2 3/16
High Static Ducted 7 Low
9/32 Static Ducted Ceiling Suspended Wall Mounted
1 13/32 6 23/32
3-13/32

3-13/32
3-13/32
2-19/32

2-19/32
2-19/32
2-7/32

2-7/32
2-7/32
Aux heater Installation Manual 5
1-7/16

1-7/16
1-7/16

communication
lines
7 9/32 7 9/32
3 13/32
7 9/32

1 13/32 1 13/321 13/32 2 7/32 6 23/32 6 23/326 23/32


1 7/16

Aux heater Aux heater


communication communication lines
lines

1 Way Cassette 2 Way Cassette 4 Way Cassette


3 13/32

3 13/32
3 13/32

2 7/32

Installation Manual 5 Manual 5


2 7/32

Installation
2 7/32

Installation Manual 5
1 7/16

1 7/16
1 7/16

Installation Manual 5
244 / 245
PIPING ACCESSORIES

HEAT RECOVERY UNIT

Model Name Included Parts


PRHR023 (2 Branch Unit) • HR unit (1EA)
PRHR033 (3 Branch Unit) • Hanging bolts M10 or M8 (4EA)
PRHR043 (4 Branch Unit) • Nut M8 or M10 (8EA)
PRHR063 (6 Branch Unit) • Washers M10 (8EA)
PRHR083 (8 Branch Unit) • Reducers

Applied Products
MULTI V 5
MULTI V IV
MULTI V WATER IV

Key Features Specification


• Max. 64 indoor units can be connected (Max. 8 indoor units per branch) Model PRHR023 PRHR033 PRHR043 PRHR063 PRHR083
• It is easy to install due to the automatic search algorithm for piping detection Number of Branch EA 2 3 4 6 8
• Subcooling cycle in HR unit makes the system efficiency maximum Maximum Connectable Capacity of Indoor Units
kW 17.5 / 35 17.5 / 52.5 17.5 / 69.5 17.5 / 69.5 17.5 / 69.5
(Per branch / unit)
Maximum Number of Connectable Indoor Units Per Branch EA 8 8 8 8 8
Connection Capacity Flexible Connection Nominal Input
Cooling kW 0.040 0.040 0.040 0.076 0.076
Maximum number of connectable indoor units : Series connection can be installed without pipes crossing. Heating kW 0.038 0.038 0.038 0.072 0.072
64 IDUs/HR unit (in case of 8 ports model) Net. Weight kg 18.5 20.3 22.0 28.3 31.8
New Dimensions (W x H x D) mm 786 x 218 x 657 786 x 218 x 657 786 x 218 x 657 1,113 x 218 x 657 1,113 x 218 x 657
8 Ports Liquid mm (inch) 9.52 (3/8) 9.52 (3/8) 9.52 (3/8) 9.52 (3/8) 9.52 (3/8)
Indoor Unit
Gas mm (inch) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8)
Piping
Liquid mm (inch) 9.52 (3/8) 12.7 (1/2) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8)
Connections
Outdoor Unit Low Pressure mm (inch) 22.2 (7/8) 28.58 (11/8) 28.58 (11/8) 28.58 (11/8) 28.58 (11/8)

ACCESSORIES
High Pressure mm (inch) 19.05 (3/4) 22.2 (7/8) 22.2 (7/8) 22.2 (7/8) 22.2 (7/8)
1 / 220 ~ 240 / 50 1 / 220 ~ 240 / 50 1 / 220 ~ 240 / 50 1 / 220 ~ 240 / 50 1 / 220 ~ 240 / 50
Power Supply Ø / V / Hz
Considering the direction for Indoor 1 / 220 / 60 1 / 220 / 60 1 / 220 / 60 1 / 220 / 60 1 / 220 / 60
64 kBtu / Port units and SVC port, connection for
reverse direction makes much easier

Max 230 kBtu

Reducers for Indoor Unit and HR Unit (Unit : mm)


Reduce Noise
Model Liquid High Pressure Low Pressure

dB(A)
46 dB(A) Indoor Unit Reducer
13dB
33 dB(A)

PRHR023

HR Unit Reducer
Conventional New

Test Condition (ISO Standard) PRHR033


- Temp. : (Cooling) 27℃ DB / 19℃ WB, 35℃ DB / 24℃ WB PRHR043
PRHR063
(Heating) 20℃ DB / 15℃ WB, 7℃ DB / 6℃ WB
PRHR083
- Operating : cooling → heating switching operation

246 / 247
PIPING ACCESSORIES

Y BRANCH AND HEADER BRANCH


For refrigerant distribution of indoor units.

Model Name Specification


Refer to specifications
Header Branch
R410A
Applied Products
(Unit : mm)
MULTI V 5
Model Gas Pipe Liquid Pipe
MULTI V IV
MULTI V III, MULTI V PLUS II, MULTI V PLUS
MULTI V S
Key Features MULTI V WATER IV ARBL054
• Various Y Branch pipe of different capacities make Multi V MULTI V WATER II (4 Branch)
installation much easier MULTI V WATER S
• Y Branch and header branch for both gas and liquid are provided.
• Insulation material is also provided for covering the branches

ARBL057
(7 Branch)

Key Application
Heat Pump System
ARBL104
(4 Branch)

ACCESSORIES
Y Branch for Header for
Indoor Units (2 Pipes) Indoor Units (2 Pipes)

ARBL107
(7 Branch)
Y Branch for Heat Pump
Outdoor Units (2 Pipes)

Heat Recovery System


ARBL1010
(10 Branch)

Y Branch for
Heat Recovery Units (3 Pipes)

HR Unit
ARBL2010
Y Branch for Heat Recovery (10 Branch)
Outdoor Units (3 Pipes)

Y Branch for
Zoning Control (2 Pipes)

HR Unit

248 / 249
PIPING ACCESSORIES

PIPING ACCESSORIES
Y Branch pipe for connection of outdoor units.

Specification Specification
Heat Pump Heat Recovery
R410A MULTI V 5, MULTI V IV, MULTI V III, MULTI V WATER IV, MULTI V WATER II R410A MULTI V 5, MULTI V IV Heat Recovery, MULTI V III Heat Recovery, MULTI V WATER IV Heat Recovery,
MULTI V WATER II Heat Recovery
(Unit : mm) (Unit : mm)

2 Outdoor Units 2 Outdoor Units


Liquid Pipe High Pressure Gas Pipe Liquid Pipe High Pressure Gas Pipe
Model High Pressure Gas Pipe Liquid Pipe Low Pressure Gas Pipe Liquid Pipe
Model High Pressure
Low Gas
Pressure
High Pressure GasPipe
Pipe Gas Pipe Liquid Pipe
Liquid Pipe High Pressure Low
GasPressure
Low PressurePipe
Gas Pipe Gas Pipe

LiquidI.D.Pipe
O.D.15.88 19.05 High Pressure Gas Pipe
O.D. 22.2 I.D. 19.05
LiquidI.D.Pipe
O.D.15.88 19.05 Low Pressure GasPressure
High
I.D.22.2 O.D. 28.58 I.D.34.9
Pipe Gas Pipe
O.D. 22.2 I.D. 19.05
LiquidI.D.Pipe
O.D.15.88 19.05 High Pressure Low
I.D.22.2O.D.
O.D.22.2
Gas
Pressure Pipe Gas Pipe
28.58I.D.I.D.34.9
19.05
LiquidI.D.Pipe
O.D.15.88 19.05 High Pressure Low
Gas
O.D. 22.2O.D.I.D.
I.D.22.2
Pressure
Pipe
19.05I.D.34.9
28.58
Gas Pipe
331
314 416
331
314
Low
416 Pressure Gas Pipe
416
Liquid 331 Pipe
314
High Pressure Low 416 Gas
416
Pressure Pipe Gas Pipe Liquid
331 Pipe
314
High Pressure Low
416
Gas
416 Pressure
Pipe Gas Pipe
I.D.15.88 I.D.15.88 I.D.15.88 I.D.15.88 408 I.D.15.88 I.D.15.88 408 I.D.15.88 I.D.15.88 408 I.D.15
408 408 408 408
I.D.28.58 I.D.28.58 I.D.28.58 I.D.28.58 I.D.28.58 I.D.28.58
I.D.28.58 I.D.28.58 I.D.22.2 O.D. 28.58 I.D.34.9 I.D.28.58 I.D.28.58O.D.15.88 I.D. 19.05 I.D.28.58
I.D.22.2O.D.
O.D.22.2 I.D.28.58
28.58I.D.I.D.34.9
19.05 O.D.15.88 I.D. 19.05 I.D.28.58 I.D.22.2
O.D. 22.2O.D.I.D. I.D.28.58
19.05
28.58 I.D.34.9
O.D.15.88 I.D. 19.05 O.D. 22.2 I.D. 19.05 O.D.15.88 I.D. 19.05 O.D. 22.2 I.D. 19.05 331 331
D.19.05 I.D.12.7 I.D.9.52 83 I.D.19.05 I.D.12.7 I.D.9.52 83 416 I.D.19.05 O.D.15.88 314I.D. I.D.12.7
19.05 I.D.9.52 83 416 I.D.19.05 O.D.15.88 314I.D. I.D.12.7
19.05 I.D.9.52 83 416 I.D.19.05
331 111 331 I.D.22.2 O.D. 28.58 I.D.34.9
I.D.22.2 111
111 I.D.22.2O.D.
O.D.22.2
28.58I.D.I.D.34.9
416 19.05
I.D.22.2 111
111
O.D. 416
22.2O.D.
I.D.22.2 I.D. 19.05I.D.34.9
28.58 I.D.22.2111 111
Liquid Pipe High Pressure Gas Pipe Liquid Pipe
408
High Pressure Gas Pipe
ARCNN21 I.D.22.2 I.D.22.2 408 I.D.22.2 408 I.D.22.2
314 I.D.31.8 I.D.34.9 416 314 I.D.31.8 I.D.34.9
I.D.31.8 I.D.34.9 416
I.D.15.88 331 ARCNB21 I.D.15.88 I.D.31.8 I.D.34.9 408
I.D.31.8 I.D.34.9 416
I.D.15.88 331 I.D.15.88 I.D.31.8 I.D.34.9
I.D.31.8 I.D.34.9 408 I.D.15
I.D.28.58 416 I.D.28.58 I.D.28.58 I.D.28.58 I.D.28.58 416 I.D.28.58 I.D.28.58
I.D.15.88 I.D.15.88 408 I.D.15.88 I.D.15.88 408 314 I.D.28.58 416 I.D.28.58 314 I.D.28.58 416
I.D.22.2 O.D.19.05 I.D.22.2 O.D.19.05 408 I.D.22.2 O.D.19.05
I.D.15.88 I.D.15.88 408 I.D.22.2 O.D.19.05
I.D.15.88 I.D.15.88 408 I.D.22
I.D.15
I.D.12.7 I.D.15.88 I.D.28.58 I.D.28.58 I.D.12.7 I.D.15.88I.D.41.3 I.D.38.1 O.D.34.9 I.D.28.58 I.D.28.58 I.D.12.7 I.D.15.88 I.D.41.3 408
I.D.38.1 O.D.34.9 I.D.12.7 I.D.15.88 I.D.41.3 408 O.D.34.9
I.D.38.1
I.D.28.58 I.D.28.58 I.D.19.05 I.D.12.7 I.D.9.52 83 I.D.28.58 I.D.28.58 I.D.19.05 I.D.12.7 I.D.9.52 83 I.D.28.58 I.D.28.58 I.D.19.05
I.D.28.58 111 I.D.28.58 I.D.28.58
I.D.28.58 111 I.D.28.58 I.D.28.58 I.D.28.58 111
I.D.12.7 I.D.9.52 83 I.D.28.58 I.D.12.7 I.D.9.52 83 I.D.22.2 I.D.28.58 I.D.22.2
I.D.28.58 111 I.D.22.2111
I.D.28.58
D.19.05 I.D.19.05 I.D.22.2 I.D.22.2
O.D.12.7 I.D.9.52 O.D.12.7 I.D.31.8
I.D.9.52 I.D.34.9 O.D.12.7
I.D.12.7 I.D.9.52 I.D.9.5283 I.D.31.8 I.D.34.9
I.D.31.8 I.D.34.9 O.D.12.7
I.D.12.7 I.D.9.5283
I.D.9.52
I.D.31.8 I.D.34.9
I.D.31.8 I.D.34.9
70 I.D.22.2 111 70 I.D.19.05
I.D.22.2 70 111 I.D.19.05 70 I.D.19.05
130 I.D.22.2 111 130 I.D.22.2 111 130 I.D.22.2111 111
O.D.15.88 I.D. 19.05 I.D.31.8 I.D.34.9 O.D.15.88 I.D. 19.05 I.D.31.8 I.D.34.9 I.D.22.2 O.D.19.05 I.D.22.2 111 I.D.22.2 O.D.19.05 I.D.22.2 I.D.22
I.D.31.8
I.D.41.3 I.D.34.9
I.D.38.1 O.D.34.9 I.D.31.8
I.D.41.3 I.D.34.9
I.D.38.1 O.D.34.9 I.D.31.8 I.D.34.9
I.D.22.2 O.D.19.05
O.D. 22.2 I.D. 19.05
I.D.22.2 O.D.19.05
O.D. 22.2 I.D. 19.05 I.D.12.7 I.D.15.88 I.D.31.8 I.D.34.9 I.D.12.7 I.D.15.88 I.D.31.8 I.D.41.3
I.D.34.9I.D.38.1 O.D.34.9
331 I.D.12.7 I.D.15.88 O.D.28.58 I.D. 19.05 331 I.D.12.7 I.D.15.88 I.D.28.58 O.D.28.58 I.D. 19.05
I.D.22.2 O.D.19.05 O.D.28.58 I.D. 19.05I.D.28.58 I.D.22.2 O.D.19.05 O.D.28.58 I.D. 19.05 I.D.28.58 I.D.22
I.D.28.58 I.D.28.58
314 I.D.22.2
416 314 I.D.41.3 I.D.38.1 O.D.34.9 I.D.22.2
416 I.D.12.7 I.D.9.52
O.D.12.7 I.D.15.88 I.D.22.2
I.D.41.3 I.D.38.1 O.D.34.9 I.D.9.52
O.D.12.7 I.D.15.88
I.D.12.7 I.D.22.2
I.D.41.3 I.D.38.1 O.D.34.9
O.D.15.88
I.D.15.88 I.D. 19.05
I.D.15.88 I.D.9.52 I.D.28.58 I.D.15.88O.D.15.88 I.D. 19.05
I.D.15.88 I.D.9.52 I.D.22.2 O.D.28.58 I.D.34.9 I.D.28.58
O.D.15.88
70 I.D. 19.05 I.D.22.2 O.D.28.58 I.D.34.9 O.D.15.88
70 I.D. 19.05 I.D.22.2 O.D.28.58 I.D.34.9
O.D.12.7 408 O.D.12.7 130 I.D.28.58 408 130 I.D.28.58 130 I.D.28.58
I.D.28.58 I.D.28.58
70 I.D.28.58 I.D.28.58 70 I.D.28.58 I.D.28.58 O.D.12.7 I.D.9.52 O.D.12.7 I.D.9.52
70 O.D.28.58 I.D. 19.05 70 O.D.28.58 130 I.D. 19.05
D.19.05 I.D.12.7 I.D.9.52 83 I.D.19.05 I.D.12.7 I.D.9.52 83 130 130
O.D.28.58 I.D. 19.05 O.D.28.58 I.D. 19.05 I.D.22.2 I.D.22.2
I.D.22.2 111 I.D.22.2 O.D.28.58 I.D.34.9 I.D.22.2 111
O.D.15.88 I.D. 19.05 I.D.22.2 O.D.28.58 I.D.34.9 O.D.15.88 I.D. 19.05 I.D.22.2 O.D.28.58 I.D.34.9
I.D.31.8 I.D.34.9 I.D.22.2 I.D.31.8 I.D.34.9 I.D.22.2 O.D.28.58 I.D. 19.05 O.D.28.58 I.D. 19.05
O.D.15.88 I.D. 19.05 3 Outdoor Units O.D.15.88 I.D. 19.05 I.D.22.2 3 Outdoor Units I.D.22.2
I.D.22.2 O.D.19.05 I.D.22.2 O.D.19.05 I.D.22.2 O.D.28.58 I.D.34.9 O.D.15.88 I.D. 19.05 I.D.22.2 O.D.28.58 I.D.34.9 O.D.15.88 I.D. 19.05 I.D.22.2 O.D.28.58 I.D.34.9
I.D.12.7 I.D.15.88 I.D.12.7 I.D.15.88 I.D.41.3 O.D.34.9 I.D.41.3 O.D.34.9 I.D.41.3 O.D.34.9
I.D.22.2 O.D.28.58 I.D.34.9 O.D.34.9 I.D.28.58 I.D.22.2 O.D.28.58 I.D.34.9 O.D.34.9 I.D.28.58 O.D.34.9 I.D.28.58
.D.19.05 I.D.12.7 Model I.D.22.2
O.D.19.05 High Pressure Gas PipeI.D.28.58
O.D.19.05 Liquid Pipe
I.D.12.7 O.D.19.05 I.D.22.2 I.D.28.58
Model High Pressure Gas Pipe Liquid Pipe Low Pressure Gas Pipe
I.D.15.88 416 I.D.15.88 416 I.D.22.2 O.D.28.58 I.D.34.9 I.D.22.2 O.D.28.58 I.D.34.9
O.D.12.7 I.D.9.52 O.D.12.7 I.D.9.52
70 408 70 408 O.D.19.05 I.D.12.7 O.D.19.05 I.D.22.2 O.D.19.05 I.D.12.7 O.D.19.05 I.D.22.2 O.D.19.05
334 334 125I.D.28.58 I.D.15.88 416 125 I.D.15.88 416 125 I
I.D.28.58 I.D.28.58 I.D.41.3 O.D.34.9 I.D.28.58 I.D.41.3 O.D.34.9 I.D.41.3 O.D.34.9
281 281 341 341
408 408 341
O.D.34.9 I.D.28.58298 334 O.D.34.9 I.D.28.58
298 334 O.D.34.9 I.D.28.58
298 I.D.28.58
O.D.28.58 I.D. 19.05 O.D.28.58 I.D. 19.05 I.D.28.58 I.D.28.58 I.D.28.58
I.D.22.2 I.D.22.2
O.D.28.58 I.D.34.9 I.D.41.3 O.D.34.9 I.D.22.2 O.D.28.58
I.D.22.2 I.D.34.9 281 I.D.22.2 O.D.28.58 I.D.41.3 O.D.34.9
I.D.34.9 281 I.D.22.2 O.D.28.58 I.D.34.9 I.D.41.3 O.D.34.9
.D.19.05 I.D.12.7 O.D.19.05 I.D.22.2 I.D.22.2 111 O.D.19.05 I.D.12.7 O.D.19.05 I.D.22.2 I.D.22.2
O.D.19.05 111 I.D.12.7 O.D.19.05 I.D.12.7 O.D.19.05
O.D.15.88
I.D.15.88 I.D. 19.05 O.D.15.88
I.D.15.88 I.D. 19.05 O.D.34.9 I.D.28.58 O.D.19.05 I.D.22.2 O.D.34.9 I.D.28.58 O.D.19.05 I.D.22.2 O.D.34.9 I.D.28.58
I.D.31.8 I.D.34.9 416 I.D.31.8
125 I.D.34.9 416 I.D.15.88 416 125 I.D.15.88 416 125 I

ACCESSORIES
408 408 I.D.22.2 408
O.D.28.58 I.D.34.9
I.D.22.2 111 I.D.22.2 408O.D.28.58 I.D.34.9
I.D.22.2 111
334 I.D.19.05 83 I.D.41.3 334 I.D.19.05 83 341 341 341
.22.2 I.D.19.05 I.D.28.58I.D.38.1 O.D.34.9 I.D.28.58 I.D.22.2 I.D.19.05
I.D.41.3 298 I.D.34.9
I.D.41.3
I.D.28.58 I.D.38.1 O.D.34.9O.D.19.05
I.D.28.58 I.D.12.7
334 O.D.19.05 I.D.22.2 I.D.31.8 I.D.34.9
I.D.28.58
I.D.41.3 298 I.D.28.58
I.D.34.9
O.D.19.05 I.D.12.7
334 O.D.19.05 I.D.22.2 I.D.31.8 I.D.34.9
I.D.28.58
I.D.41.3 298 I.D.28.58I.D.34.9
O.D.19.05
281 281 125 111 I.D.15.88 416 125 111 I.D.15.88 416 125 111 I
I.D.22.2 I.D.19.05 281 I.D.19.05 83 I.D.41.3 I.D.38.1 408
O.D.34.9 I.D.22.2 I.D.19.05 281 I.D.19.05 83 I.D.41.3 I.D.38.1 408 O.D.34.9 I.D.22.2 I.D.1
I.D.28.58 341 I.D.28.58 341 341
298 334 I.D.28.58 298 I.D.28.58 334 I.D.28.58 298 I.D.28.58
I.D.22.2 111 I.D.22.2 111 281 I.D.28.58 111 281 I.D.28.58 111
I.D.15.88 I.D.12.7 130 I.D.15.88 I.D.12.7 130 I.D.22.2 I.D.22.2
I.D.31.8 I.D.34.9 I.D.31.8 I.D.34.9 I.D.31.8 I.D.34.9 I.D.31.8 I.D.34.9
I.D.28.58 O.D.22.2 ARCNN31
I.D.19.05 83 I.D.28.58 O.D.22.2 I.D.41.383
I.D.19.05I.D.53.98
I.D.28.58 111
I.D.34.9 ARCNB31
I.D.15.88 I.D.12.783 I.D.41.3 130 I.D.28.58 111
I.D.34.9 I.D.15.88 I.D.12.783 I.D.41.3130 I.D.28.58 111
I.D.34.9
.22.2 I.D.19.05 I.D.41.3 I.D.22.2 I.D. 34.9 O.D.28.58
I.D.38.1 O.D.34.9
O.D.28.58 I.D.34.9I.D.22.2 I.D.22.2 I.D.19.05 I.D. 44.5 O.D.41.3 I.D.41.3 I.D.22.2 I.D. 34.9
I.D.38.1 O.D.34.9
O.D.28.58 O.D.28.58
I.D.22.2 I.D.34.9 I.D.22.2
I.D.19.05 I.D.19.05 I.D.53.98 I.D. 44.5
I.D.41.3 I.D.38.1 O.D.41.3 I.D.22.2
O.D.34.9 111 I.D.22.2 I.D.19.05 I.D.19.05 I.D.53.98
I.D.41.3 I.D.38.1 I.D. 44.5 O.D.41.3
O.D.34.9 I.D.22.2 111 I.D.22.2 I.D.1
.D.19.05 I.D.12.7 O.D.19.05 I.D.22.2 O.D.19.05 I.D.12.7 O.D.19.05 I.D.22.2 I.D.31.8 I.D.34.9 I.D.31.8 I.D.34.9
I.D.15.88 416 I.D.15.88 I.D.41.3 I.D.34.9 416 I.D.28.58 O.D.22.2 I.D.41.3 I.D. 34.9 O.D.28.58
I.D.34.9 I.D.22.2 I.D.28.58 O.D.22.2 I.D.41.3 I.D. 34.9 O.D.28.58I.D.34.9
I.D.22.2 111 I.D.28.58
O.D.15.88 I.D.19.05 I.D.28.58 O.D.15.88 I.D.19.05 111 I.D.28.58 111
408 408 I.D.22.2 I.D.19.05 I.D.19.05 83 I.D.41.3 I.D.38.1 O.D.34.9 I.D.28.58 I.D.22.2 I.D.19.05 I.D.19.05 83 I.D.41.3 I.D.38.1 O.D.34.9 I.D.28.58 I.D.22.2 I.D.1
334 I.D.53.98 I.D.44.5 O.D.41.3
I.D.28.58 I.D.28.58 334 I.D.53.98
I.D.28.58I.D.44.5 O.D.41.3 I.D.28.58
I.D.15.88 I.D.12.7 130 I.D.15.88 I.D.12.7 I.D.22.2 O.D.28.58 I.D.34.9
I.D.28.58 130 O.D.15.88 I.D.19.05 I.D.22.2 O.D.28.58 I.D.34.9
I.D.28.58 O.D.15.88 I.D.19.05 I.D.22.2 O.D.28.58 I.D.34.9
I.D.28.58
281 281 I.D.15.88 I.D.12.7 130 I.D.15.88 I.D.12.7 130
I.D.53.98 I.D. 44.5 O.D.41.3 I.D.53.98I.D.44.5
I.D.53.98 I.D. 44.5 O.D.41.3
O.D.41.3 I.D.28.58 I.D.53.98 I.D.53.98
I.D.44.5 I.D. 44.5 O.D.41.3I.D.28.58
O.D.41.3
I.D.28.58 O.D.22.2 I.D. 34.9 O.D.28.58 I.D.22.2 I.D.28.58 O.D.22.2 I.D. 34.9 O.D.28.58
I.D.28.58 I.D.22.2
O.D.22.2 I.D.28.58 O.D.22.2 I.D.28.58
111 I.D.28.58 111 I.D.15.88 I.D.12.7 I.D.28.58
130 I.D. 34.9 O.D.28.58 I.D.22.2 I.D.15.88 I.D.12.7 I.D.28.58
130 I.D. 34.9 O.D.28.58 I.D.22.2
I.D.22.2 I.D.53.98 I.D. 44.5 O.D.41.3 I.D.22.2 I.D.53.98 I.D. 44.5 O.D.41.3 I.D.53.98 I.D. 44.5 O.D.41.3
O.D.15.88 I.D.19.05 I.D.31.8 I.D.34.9 O.D.15.88 I.D.19.05 I.D.31.8 I.D.34.9
I.D.22.2 O.D.28.58 I.D.34.9 I.D.28.58 O.D.22.2 O.D.15.88 I.D.19.05 I.D.22.2 O.D.28.58
I.D. 34.9 O.D.28.58 I.D.34.9
I.D.22.2 I.D.28.58 O.D.22.2 O.D.15.88 I.D.19.05 I.D.22.2
I.D. 34.9 O.D.28.58
O.D.28.58 I.D.22.2I.D.34.9 I.D.28.58
.22.2 I.D.19.05 I.D.19.05 83 I.D.53.98 I.D.44.5
I.D.38.1 O.D.41.3
I.D.41.3O.D.34.9 O.D.34.9 I.D.22.2 I.D.19.05 I.D.19.05 83 I.D.53.98 I.D.44.5
I.D.38.1 O.D.41.3
I.D.41.3O.D.34.9 O.D.34.9
O.D.19.05 I.D.22.2 I.D.28.58 I.D.41.3 I.D.44.5 O.D.19.05 I.D.22.2 I.D.28.58 I.D.41.3 I.D.44.5 I.D.53.98 I.D.44.5 O.D.41.3 I.D.53.98 I.D.44.5 O.D.41.3
I.D.22.2 O.D.28.58 I.D.34.9 O.D.15.88 I.D.19.05 I.D.22.2 O.D.28.58 I.D.34.9 O.D.15.88 I.D.19.05 I.D.22.2 O.D.28.58 I.D.34.9
334 341 I.D.28.58 334 341 I.D.28.58
I.D.53.98 I.D.44.5 O.D.41.3 I.D.53.98 I.D.44.5 O.D.41.3
281 298 281 298
I.D.15.88 I.D.12.7 130 I.D.15.88 I.D.12.7 130
I.D.28.58 O.D.22.2 I.D.28.58 O.D.22.2
O.D.19.05 I.D.22.2 I.D.28.58 O.D.34.9 I.D. 34.9 O.D.28.58
I.D.41.3 I.D.44.5I.D.22.2
4 Outdoor Units O.D.19.05 I.D.22.2 I.D.28.58 O.D.34.9 I.D. 34.9 O.D.28.58
I.D.41.3 I.D.44.5I.D.22.2 4 Outdoor Units
.22.2 I.D.19.05 I.D.19.05 83 I.D.22.2 I.D.19.05 I.D.19.05 83
334O.D.15.88 I.D.19.05 I.D.41.3 341 I.D.34.9 111 334O.D.15.88 I.D.19.05 I.D.41.3 341 I.D.34.9 111
281 Model High
I.D.53.98 Pressure
I.D.44.5 298
O.D.41.3 Gas Pipe Liquid
281 Pipe O.D.41.3 I.D.44.5 I.D.53.98 298
I.D.53.98 I.D.44.5 O.D.41.3 O.D.19.05 I.D.22.2 Model
I.D.28.58 High Pressure
O.D.41.3
O.D.34.9 I.D.41.3Gas
I.D.44.5 Pipe
I.D.53.98
I.D.44.5 Liquid
O.D.19.05 Pipe I.D.28.58
I.D.22.2 Low Pressure
O.D.41.3
O.D.34.9 Gas
I.D.44.5I.D.44.5
I.D.41.3 Pipe
I.D.53.98 O
415 334 415
341 334 341 415
I.D.15.88 I.D.12.7 I.D.15.88 I.D.12.7
I.D.31.8 I.D.28.58 O.D.22.2 I.D.31.8 I.D.28.58 O.D.22.2 375 281 375
298 281 298 375
I.D.53.98 I.D.44.5 O.D.41.3 I.D.28.58 I.D.53.98 I.D.44.5 O.D.41.3 I.D.28.58
.22.2 I.D.19.05 I.D.19.05 83 I.D.22.2 I.D.19.05 I.D.19.05 83
O.D.41.3 I.D.44.5 I.D.53.98I.D.41.3 O.D.19.05
I.D.41.3 I.D.34.9 111 I.D.34.9 111 I.D.22.2 I.D.28.58 O.D.41.3
O.D.34.9 I.D.44.5
I.D.41.3 I.D.53.98
I.D.44.5 O.D.19.05 I.D.22.2 I.D.28.58 O.D.34.9
O.D.41.3
I.D.41.3
I.D.44.5I.D.44.5
I.D.53.98 O
415 334 415
341 341 415
O.D.19.05 I.D.22.2 I.D.28.58
O.D.15.88 I.D.19.05 O.D.34.9
I.D.34.9 I.D.41.3
O.D.28.58 I.D.44.5
I.D.22.2 O.D.19.05 I.D.22.2 I.D.28.58
O.D.15.88 I.D.19.05 O.D.41.3 I.D.44.5 I.D.53.98 O.D.34.9 I.D.41.3
134 I.D.34.9 O.D.28.58
I.D.44.5
I.D.22.2I.D.22.2
O.D.19.05
I.D.19.05 I.D.22.2 I.D.28.58
I.D.19.05 83 O.D.34.9 I.D.44.5
O.D.41.3 I.D.41.3 I.D.53.98
I.D.44.5 134 O.D.19.05 334
I.D.22.2 I.D.19.05 I.D.22.2 I.D.28.58
I.D.19.05 83 O.D.41.3
O.D.34.9 I.D.44.5I.D.44.5
I.D.41.3 I.D.53.98 134 O
I.D.22.2 I.D.
I.D.44.48 I.D.53.98 375 I.D.41.3 281 I.D.44.48 375
I.D.41.3 I.D.53.98298 I.D.41.3
I.D.34.9 111 281 298
I.D.41.3I.D.44.48 I.D.53.98 375 I.D.34.9 I.D.41.3
111
334 I.D.15.88 I.D.12.7 341 334 I.D.15.88 I.D.12.7 415 341 415
341 341 415
I.D.31.8 I.D.28.58 281
O.D.22.2 I.D.53.98 I.D.44.5 O.D.41.3 I.D.31.8 I.D.28.58 281
O.D.22.2 I.D.53.98 I.D.44.5 O.D.41.3 334 334
298 I.D.28.58 375 298 I.D.28.58 375
298 298 375
281 281
I.D.15.88 I.D.12.7 I.D.15.88 I.D.12.7
I.D.22.2 I.D.28.58 O.D.22.2 I.D.19.05
I.D.31.8I.D.19.05 83 I.D.22.2
I.D.31.8I.D.19.05
I.D.28.58 O.D.22.2 I.D.19.05 83 I.D.22.2
I.D.31.8I.D.I
I.D.44.48 I.D.53.98 I.D.28.58 134
I.D.41.3 I.D.53.98
I.D.41.3 I.D.44.5
I.D.44.48 I.D.53.98O.D.41.3 I.D.28.58134
I.D.28.58
I.D.41.3
I.D.34.9 111 I.D.53.98 I.D.44.5I.D.53.98
I.D.41.3I.D.44.48 O.D.41.3 I.D.28.58
I.D.34.9 I.D.28.58
I.D.41.3111 134
O.D.15.88 I.D.19.05 I.D.34.9 O.D.28.58 I.D.22.2 O.D.15.88 I.D.19.05 I.D.34.9 O.D.28.58 I.D.22.2
.22.2 I.D.19.05 I.D.19.05 83 I.D.22.2 I.D.19.05 I.D.19.05 83
ARCNN41 I.D.41.3 I.D.34.9 111 I.D.22.2 I.D.41.3I.D.41.3
O.D.28.58 I.D.34.9 134 I.D.34.9
I.D.22.2 I.D.19.05111 ARCNB41
I.D.19.05 83
I.D.41.3I.D.22.2 I.D.41.3
I.D.34.9
O.D.28.58 I.D.34.9 134 I.D.22.2 I.D.19.05 I.D.19.05 83
I.D.41.3I.D.44.48
I.D.22.2 I.D.34.9
O.D.28.58 I.D.41.3
I.D.34.9 134 I.D.22.2 I.D.
I.D.44.48 I.D.53.98 I.D.44.48 I.D.53.98 111 I.D.53.98 111
O.D.15.88
I.D.15.88I.D.19.05
I.D.12.7 I.D.34.9 O.D.28.58 I.D.22.2 O.D.15.88
I.D.15.88I.D.19.05
I.D.12.7 I.D.34.9 O.D.28.58 I.D.22.2
I.D.28.58 I.D.31.8 I.D.28.58 O.D.22.2 I.D.53.98 I.D.44.5 O.D.41.3 I.D.28.58
I.D.28.58 I.D.31.8 I.D.28.58 O.D.22.2 I.D.53.98 I.D.44.5 O.D.41.3 I.D.28.58I.D.28.58 I.D.31.8 I
I.D.15.88 I.D.12.7 I.D.15.88 I.D.12.7 I.D.15.88 I.D.12.7 I.D.15.88 I.D.12.7
I.D.31.8 I.D.28.58 O.D.22.2 I.D.53.98 I.D.44.5 O.D.41.3 I.D.28.58 I.D.31.8 I.D.28.58 O.D.22.2 I.D.53.98 I.D.44.5 O.D.41.3 I.D.31.8I.D.28.58
I.D.28.58 O.D.22.2 I.D.31.8 I.D.28.58 O.D.22.2 I.D.31.8 I
I.D.22.2 O.D.28.58 I.D.34.9 I.D.28.58 I.D.53.98I.D.22.2
I.D.44.5 O.D.28.58
O.D.41.3 I.D.34.9
I.D.28.58
I.D.28.58 I.D.53.98 I.D.44.5 O.D.41.3
I.D.22.2 I.D.28.58
O.D.28.58 I.D.28.58
I.D.34.9
O.D.15.88 I.D.19.05 I.D.34.9 O.D.28.58 I.D.22.2 O.D.15.88 I.D.19.05 I.D.34.9 O.D.28.58 I.D.22.2
O.D.15.88 I.D.19.05 I.D.34.9 O.D.28.58 I.D.22.2 O.D.15.88 I.D.19.05 I.D.22.2 O.D.28.58 I.D.34.9 I.D.34.9 O.D.28.58 I.D.22.2 O.D.15.88 I.D.19.05
I.D.22.2 O.D.28.58 I.D.34.9
O.D.15.88 I.D.19.05
I.D.22.2 O.D.28.58 I.D.34.9
I.D.34.9 O.D.28.58 I.D.22.2 I.D.34.9 O.D.28.58 I.D.22.2

250 / 251
PIPING ACCESSORIES

PIPING ACCESSORIES
Y Branch pipe for connection of outdoor units.

Specification Specification
Heat Pump, Heat Recovery Zone Control Heat Recovery
R410A MULTI V 5, MULTI V IV, MULTI V III, MULTI V PLUS II, MULTI V PLUS, MULTI V S, MULTI V MINI, R410A MULTI V 5, MULTI V IV Heat Recovery, MULTI V III Heat Recovery, MULTI V WATER IV Heat Recovery,
MULTI V SPACE II, MULTI V WATER IV, MULTI V WATER S, MULTI V WATER II MULTI V WATER II Heat Recovery
(Unit : mm) (Unit : mm)

Model Gas Pipe Liquid Pipe Model High Pressure Gas Pipe Liquid Pipe Low Pressure Gas Pipe

I.D12.7 I.D15.88 I.D15.88


I.D9.52 I.D9.52 I.D6.35
I.D12.7 I.D15.88
I.D9.52 I.D9.52 I.D6.35

I.D15.88 I.D6.35
ARBLN01621
ARBLB01621 I.D6.35 I.D15.88

I.D12.7 I.D15.88 I.D. 9.52 I.D6.35 I.D12.7


I.D19.05 I.D12.7 I.D15.88
I.D. 9.52 I.D6.35 I.D19.05
O.D9.52 I.D12.7
O.D15.88 O.D9.52 O.D15.88

I.D22.2 I.D19.05 I.D15.88 I.D19.05


I.D9.52 I.D9.52 I.D6.35

I.D12.7
I.D25.4
I.D9.52 I.D9.52 I.D6.35 I.D22.2 I.D19.05 I.D15.88 I.D19.05
I.D12.7 I.D12.7
O.D19.05
ARBLN03321 I.D28.58
I.D15.88 I.D12.7
I.D12.7
I.D19.05 I.D25.4
ARBLB03321 I.D12.7 I.D12.7

I.D9.52 I.D6.35
I.D28.58 O.D19.05
I.D25.4 O.D19.05
O.D19.05 I.D12.7 I.D15.88 I.D12.7
I.D 22.2 I.D 22.2 I.D9.52 I.D6.35
I.D19.05
I.D12.7

I.D25.4 O.D19.05
O.D19.05
I.D 22.2 I.D 22.2

Model Gas Pipe Liquid Pipe


I.D19.05
I.D19.05
I.D19.05 I.D19.05 I.D12.7 I.D15.88 I.D15.88 I.D12.7 I.D28.58 I.D22.2 I.D15.88

ACCESSORIES
I.D28.58 I.D22.2 I.D15.88 I.D12.7 I.D15.88 I.D15.88 I.D12.7

I.D12.7 I.D12.7
I.D12.7 I.D12.7 I.D19.05 I.D31.8
ARBLN07121 I.D31.8 I.D19.05 ARBLB07121
I.D15.88 I.D19.05 I.D19.05 I.D15.88
I.D19.05 I.D15.88 I.D15.88 I.D19.05
O.D12.7 I.D6.35
O.D12.7 I.D6.35
I.D31.8 O.D22.2 I.D9.52 I.D31.8 O.D22.2
I.D9.52
I.D34.9 I.D28.58 O.D19.05 I.D28.58 I.D9.52 I.D9.52
I.D34.9 I.D28.58 O.D19.05 I.D28.58
O.D31.8 I.D22.2 O.D12.7 O.D12.7 O.D31.8 I.D22.2

I.D34.9
I.D34.9 I.D41.3 I.D38.1 I.D28.58
I.D34.9
I.D34.9 I.D41.3 I.D38.1 I.D28.58
I.D28.58
I.D38.1

I.D28.58
ARBLN14521 I.D41.3 O.D34.9
I.D34.9 I.D22.2 I.D38.1

I.D41.3
O.D38.1 I.D38.1
ARBLB14521 I.D41.3 O.D34.9
I.D34.9 I.D22.2

I.D41.3
O.D38.1 I.D38.1

I.D12.7 O.D28.58 I.D19.05


O.D22.2 I.D15.88
O.D15.88 I.D22.2
I.D19.05
I.D15.88 I.D12.7 O.D28.58 I.D19.05
O.D22.2
I.D19.05 O.D15.88 I.D22.2

Model Gas Pipe Liquid Pipe

Model High Pressure Gas Pipe Liquid Pipe Low Pressure Gas Pipe

I.D34.9 I.D34.9 I.D.44.48


I.D.41.3 I.D38.1 I.D28.58 I.D.53.98 I.D41.3 I.D38.1
2 I.D.25.4
I.D25.4 I.D22.2 I.D.22.2 I.D.19.05 2
1
I.D28.58 2 I.D.44.48
I.D38.1
ARBLN23220 I.D34.9 I.D22.2 125 I.D.44.48 I.D41.3 I.D38.1 134
I.D.25.4
471 I.D.22.2 I.D.19.05 96 420
3 3
517
490
346 3
ARBLB23220 I.D19.05 379 I.D.34.9 I.D31.8
O.D22.2 I.D15.88 I.D.53.98 I.D.25.4 I.D.22.2
O.D38.1 I.D41.3 O.D34.9 I.D38.1 O.D.38.1 I.D.28.58 O.D.44.48
O.D.28.58
3 2 3 I.D41.3 I.D19.52 2 2
I.D.15.88 X2 X2 3
O.D.19.05 I.D.12.7 O.D12.7 I.D6.35 3 3
120 90 130
175 100 115
2 3 X2 3
I.D12.7 O.D28.58 I.D22.2 I.D12.7 I.D.19.05 I.D.15.88
3 110 110
2 I.D19.05 3 3
O.D15.88
O.D15.88 O.D.22. 2
70 120
70 120

252 / 253
PIPING ACCESSORIES

REFRIGERANT CHARGING KIT DRAIN HOSE


Recharging refrigerant after a pump down or when refrigerant is either insufficient or excessive. Easy drain installation

Model Name Model Name


PRAC1 PHDHA05T
PHDHA07T
Applied Products PHDHA05B
MULTI V 5
PHDHA07B
MULTI V IV Heat Pump
MULTI V IV Heat Recovery Applied Products
MULTI V III Heat Pump MULTI V Indoor units
MULTI V III Heat Recovery
MULTI V PLUS II
MULTI V SYNC II

How to Use Key Features


•A  rrange manifold, capillary assembly, refrigerant vessel and scale • It reduces the installation time by over 40% with elbow-less drain hose
• Connect manifold to the gas pipe service valve of outdoor uint as shown in the figure • Drain pump covers maximum 700mm high, featuring easy piping installation
• Connect manifold and capillary tube. Use designated capillary assembly only.
If designated capillary assembly isn’t used, the system may get damaged
• Connect capillary and refrigerant vessel
• Purge hose and manifold
• After “568” is displayed, open the valve and charge the refrigerant Key Application
• Ceiling Mounted Cassette and Ceiling Concealed Duct (refer to PDB for applicable model)

ACCESSORIES
Max. 450
Key Application
Mainfold Ceiling Mounted Cassette Flexible Hose
250 (4 Way, 1 Way) Make a Loop Form
Ceiling Concealed Duct
(with Drain Pump)
Capillary Assembly
(Unit : mm)

Specification
* Fault Detect & Diagnosis
Model Length Quantity
PHDHA05T 500mm 30EA
PHDHA07T 700mm 30EA
PHDHA05B 500mm 5EA

Refrigerant PHDHA07B 700mm 5EA

254 / 255
PIPING ACCESSORIES

STOPPER VALVES

Model Name Application


PRVT120 (Under 12.7mm) (Room 3 & 4 : in useCut/ Room
inlet side1of&the
2 :connector,
need to and
install
weldindoor units)
In case of the installation of additional
PMVT780 (Under 22.2mm) the pipe indoor unit, outlet side connector should
be cut according to installation pipe.
PMVT980 (Under 28.58mm)

"A"

9.52 : 19.05

3.0m Room 1
Key Features
9.52 : 19.05 Closed State
Pin (Closed) Pin (Open)
• This unit can be applied for the additional indoor unit’s installation 3.0m
• This unit can be applied for each indoor unit’s service In case of installation of stopper valve,
Stopper Valves
9.52 : 15.88In case of installation of additional
flare part should be facing towards indoor unit, SVC valve should be in Room 2
10.0m
additional indoor unit. closed state

-When welding, service valve shoud be wrapped by wet cloth.


Specification 9.52 : 15.88
5.0m
Model Specification Room 3

6.35 : 12.7
3.0m
PRVT120
Room 4

• In case of installation of additional indoor unit, refrigerant of used indoor unit must be discharged. (Room 3 & Room 4)
PRVT780 • If stopper valve is already installed, you can install additional indoor unit without refrigerant loss from the entire system.

ACCESSORIES
• After installation of additional indoor unit, you just need refrigerant charging for “A” section.
• Then, open the Stopper Valve.
Cut inlet side of the connector, and weld In case of the installation of additional
the pipe indoor unit, outlet side connector should
be cut according to installation pipe.
PRVT980

Open / Close Port


Charge Port

9.52 : 19.05
3.0m

9.52 : 19.05 Pin (Closed) Open State


Pin (Open)
Cut inletCut
sideinlet
of the In case of the installation of additional 3.0m Stopper Valves
sideconnector, and weldand weld
of the connector, In case of the installation of additional
the pipethe pipe indoor unit, outlet
indoor unit,side connector
outlet should should
side connector In case of installation of9.52 : 15.88
stopper valve, In case of installation of additional
be cut according to installation pipe.
be cut according to installation pipe. flare part should be facing towards indoor unit, SVC valve should be in
How to Install additional indoor unit. 10.0m closed state
6.35 : 12.7
3.0m
-When welding, service valve shoud be wrapped by wet cloth. Room 1

9.52 : 15.88
Pin (Closed)
Pin (Closed)
Pin (Open)
Pin (Open) 3.0m
Room 2
Cut
1. inletthe
CCut
ut sideinlet
of the connector,
ofside of theand weldweld In case
con- Iof
2.case the installation
f installing of additional
additional indoor 3.case
When installingof astopper
stopper
inlet side the connector, and In of the installation of additional In of installation
In case valve,valve,
of installation of stopper
4. installation
In case of
valve,
When installing anadditional
of additional
In case of installation of additional
the the
pipepipe indoor unit,unit,
indoor outlet sideside
outlet connector should
connector should
nector, and weld the pipe be cut units, the
according to outlet side
installation connec-
pipe. the
flare flare
part
flare part
should
part be should
facing
should be facing
betowards
facing towards indoor unit, indoor
SVC
indoor unit,
valve
unit, SVC thebe
should
valve SVC
in be
should valve
in
be cut according to installation pipe. additional indoor unit. closed state
tor should be cut according to towards additional indoor unit.
additional indoor unit. should be in closed state.
closed state Room 3
installation pipe.
-When -When
welding,welding,
service service
valve shoud
valvebe wrapped
shoud by wet by
be wrapped cloth.
wet cloth.
* When welding, service valve shoud be wrapped by wet cloth. Room 4

Pin (Closed)
Pin (Closed) Pin (Open)
Pin (Open)

In case of installation
In case of stopper
of installation valve,
of stopper valve, In case of installation
In case of additional
of installation of additional
flareflare
partpart
should be facing
should towards
be facing towards indoor unit,unit,
indoor SVCSVCvalve should
valve be in
should be in
additional indoor unit.
additional indoor unit. closed state
closed state

-When welding,
-When service
welding, valve
service shoud
valve be wrapped
shoud by wet
be wrapped cloth.
by wet cloth. 256 / 257