Outdoor Preview
Outdoor Preview
CATALOUGE
002 / 003
WHY LG MULTI V
2017 ~
・ Heat Recovery
・ Ø7.0 Corrugate
・ Fuzzy Algorithm
・ AC Inverter
・ R410A
Since the time when LG launched Korea’s first residential air MULTI V’s wide range of VRF solutions satisfies various building
conditioner in 1968, the company has worked to continuously types and sizes. MULTI V S’s size discharge was designed
enhance its technological innovation and reliability. As a for small to mid-sized buildings while MULTI V Water is a
result of sustained improvement, LG VRF launched the first water-cooled VRF solution with variable water flow control
generation of MULTI V in 2006 and achieved significant technology.
development. With the best-in-class compressor technology
and innovation applied to every part and control solution, In 2017, the ultimate VRF solution was introduced with MULTI V 5.
MULTI V has evolved to be on of the world’s most efficient This generation has fully improved its technological potential
and reliable VRF solutions. with the powerful and reliable yet economical Ultimate Inverter
Compressor, effective corrosion resistance with the Ocean
The first and second generations of MULTI V boasted inverter Black Fin coating and enlarged fans. Dual Sensing Control
technology and non-ozone depleting technology, while MULTI V III was offers the most pleasant indoor environment while minimizing
produced with cutting edge tech like oil return with HiPORTM unnecessary energy loss by sensing both temperature and
and double compression features with mid-pressure refrigerant humidity to efficiently manage cooling, heating and part load.
allowed by Vapor Injection. The innovative technologies of
MULTI V’s fourth generation brought about product leadership MULTI V 5 has been designed for the ultimate efficiency,
in efficiency. Its Smart Load Control adjusts with the outdoor performance, flexibility, comfort and control, ensuring the most
temperature, while optimizing refrigeration management and pleasant indoor experience.
heat exchange for both cooling and heating.
!"#$
· High Efficiency
· Ultimate Inverter Compressor
· Large Capacity ODU with Biomimetics
Technology Fan
· Dual Sensing Control
· Ocean Black Fin
· Ø7.0 Corrugate · Heat Recovery · High Pressure Oil Return · Active Refrigerant Control
· Fuzzy Algorithm · Ø7.0 Wide louver · Vapor Injection · Variable Heat Exchanger Circuit
· AC Inverter · Fuzzy Algorithm · Continuous Heating · Smart Load Control
· R410A · LGDC Inverter · Smart Oil Return
· Vapor Injection (Advanced)
004 / 005
'()'*+,,(-(+.-/
%&'()*+,&-./)&01./',2345+1&06)'57(0-4-6&5/8)/.7()+/)94'&:+'5);0*5,'5,)<-:=,5//-,)+01)>.+4)?50/&06)<-0',-48)@A)B9@C;)D)E)
offers the world class high efficiency. These advanced technologies help MULTI V 5 to achieve the lowest energy
consumption while preserving the environment.
All Inverter
Provide high efficiency with low vibration and low noise
G/)+),5/.4')-H)'(5)I&-:&:5'&7/)'57(0-4-62)&0*50'51)'(,-.6()25+,/)-H)T-&0')/'.12)L&'()>5=+,':50')-H)B57(+0&7+4)+01)
G5,-/=+75)N06&055,&06)-H)?5-.4)M+'&-0+4)90&*5,/&'28)'(5)H+0)-H)B9@C;)D)E)&07,5+/51)L&01)7+=+7&'2)L(&45)&'),51.751)&'/)
power consumption when operating.
010 / 011
DUAL SENSING
CONTROL
The cooling load is mainly based on the amount of both sensible heat load and latent heat load. Most importantly, the
cooling load is keen to, and thus, greatly affected by external humidity, rather than the outdoor temperature. For such
,5+/-08)>.+4)?50/&06)<-0',-4)-H)B9@C;)D)E)/50/5/)I-'()'5:=5,+'.,5)+01)(.:&1&'2)+01)+==4&5/)/50/51)1+'+)H-,)4-+1)
control in order to obtain in-depth understanding of sensible heat load and latent heat load. This helps preventing
5J75//&*5)7--4&06)4-+1)/.==42)+01)5*50'.+442)-HH5,/)'(5):-/')=45+/+0')+01)7-:H-,'+I45)7--4&06)50*&,-0:50')'(5)./5,/)
want with reduction in energy consumption.
Previous VRF
0Single Sensing] 0Dual Sensing]
Seasonal
Efficiency
DID YOU KNOW Up to 18%
THAT VRF UNTIL NOW (vs. standard mode
HAS ONLY SENSED at 26HP)
SINGLE INFORMATION?
Comfort Cooling
B&41)7--4&06)-=5,+'&-0)L&'(-.')/'-==&06)
&0)I5'L550)H-,):+J&:&K51)./5,)7-:H-,'
Improved
Indoor Comfort
OCEAN BLACK FIN
HEAT EXCHANGER
LG’s exclusive “Ocean Black Fin” heat exchanger is specially designed for durable and long-lasting performance even
in corrosive environments. The black coating is applied for protection from various corrosive external conditions and
the hydrophilic film keeps water from accumulating on the heat exchanger’s fin, minimizing moisture buildup. This
improvement in durability prolongs the product’s lifespan and lowers both the operational and maintenance costs.
012 / 013
10 ADVANTAGES
OF MULTI V
1 ULTIMATE
EFFICIENCY 3 SUPERIOR
DURABILITY 4 DESIGN
FLEXIBILITY
Ultimate Energy Saving with LG’s exclusive “Black Fin” Flexible Installation with
Dual Sensing Control. heat exchanger is designed Large Capacity Outdoor Unit.
to perform even in corrosive
MULTI V 5 enables easy type
Environments.
change-over to suit the purpose
of any building.
Hydrophilic film
Acryl + Epoxy +
Melamine resin
2
Certified protection
INNOVATIVE
TECHNOLOGIES
MULTI V 5
- Ultimate Inverter Compressor ※ Verification of corrosion resistance performance
- Declared by TUV Rheinland
- Biomimetics Technology Fan - Test Method B of ISO21207
- Test condition : Salt contaminated condition
+ severe industrial/traffic
environment
Scroll Compressor
5 SMART
CONTROLS 6 BUSINESS
SUPPORT
MULTI V responds to diverse building - Engineering Tools & Support
environments with LG ThinQ-based - LG Air Conditioning Academy
AI control and individual/central - Asia Regional HQ
integrated control solutions.
7 DIVERSE
PRODUCT
LINE UP
9
MADE IN
10
BRAND
LG offers a specialized product
KOREA RELIABILITY
lineup suited for various
business environments, perfectly LG MULTI V line-up emphasizing Global production sites facilitate
responding to the unique high quality and durability with world-class customer service.
conditions no matter the use case. Korea made products.
8 DIVERSE
INTEGRATED
SOLUTION
Integrated solution optimized for
various business environments,
including hot water, AHU, BMS,
and EMS.
014 / 015
WHY LG MULTI V
I II III
Energy Estimation Model Selection Installation
& Energy Modeling & Design Environment
Simulation
01 Planning
LATS
Energy
02 Schematic Design
LATS
HVAC
03 Design Development
Energy
Modeling LATS CAD
- eQUEST Ⓡ LATS REVIT
- TRNSYS
CFD
04 Construction Design - FLUENT
05 Construction
03 Model Selection
LATS HVAC
LATS HVAC is a model selection program that accurately and quickly selects the
most suitable LG commercial air conditioning systems for each design.
In addition to model selection, faster estimation on refrigerant piping diameter
and additional refrigerant is possible, along with auto printing of reports.
04 Design
LATS CAD
LATS CAD enables faster and more accurate 2D design of LG commercial air
conditioning systems. It also enables modules for quotation and installation
review that minimize inherent problems during installation and commissioning.
※ AutoCAD program is required.
LATS REVIT
LATS REVIT allows BIM users to have an attractive 3D design of LG commercial
air conditioning systems with embedded calculations for refrigerant and efficiency
features.
※ AutoCAD Revit program is required.
05 Environment Simulation
CFD Analysis
CFD Analysis is applied in areas of estimating : indoor airflow and temperature
distribution while operating VRF products, outdoor airflow distribution, and
noise level. By running a simulation before construction, engineers estimate
possible issues and find optimal solutions for malfunctions that could occur after
construction.
016 / 017
WHY LG MULTI V
BENEFITS OF LG MULTI V
Benefits for
Building Owners
Efficient Management & Cost Reduction
- Fault Detection Diagnosis enables easy maintenance
- Requires no extra manpower for regular
maintenance
- With diverse control systems, maintenance cost is
minimized
Benefits for
Developers & Construction Companies
Green Solutions
- Optimized for LEED/BREEAM certification
- Renewable energy solution provided through
geothermal application
Benefits for
End-users
Convenient Functions
- Low-noise operation provides a pleasant
environment
* Dual Smart Load Control ESEER based, below 50% humidity, model ARUM260LTE5
** LG internal test result
018 / 019
WHY LG MULTI V
APPLICATION SOLUTIONS
Office
Supporting efficiency with flexibility
The MULTI V series revitalizes the workspace by providing fresh air at all times. LG's intelligent control solutions add comfort
to any space.
Commercial
Maximizing business, minimizing cost
The highly efficient, energy saving MULTI V 5 and MULTI V reduces operation costs, and provides comfort that suits any
purpose and any space, helping to invest the extra space and expense to your business.
Condominium Apartments
MULTI V 5 HR/HP with various IDU enables optimal solution, providing comfort to every space through individual zone
control and hot water solution.
Hospitality
Meeting diverse needs
• MULTI V 5 • DX AHU • HYDRO KIT • Low Static Duct • Remote control • Refrigerant leak detector
The diverse applications that can be applied to MULTI V 5 helps bring just the right solution to a sophisticated hotel business.
020 / 021
WHY LG MULTI V
ROOM
Indoor Unit
Buzzer Alarm
Card Key
MULTI V 5
Outdoor Unit
Cooling I/O Module
HR Unit
Ball Valve
(Field supply)
MULTI V 5
Outdoor Unit
Refrigerant Remote
Detector Controller
Power PDI
100 kWh
AHU
Target
AC Smart (ACP)
Forecasting
BMS Protocol
BMS System
022 / 023
LINE-UP
● ● ●
● ● ● ● ● ● ●
HEAT RECOVERY
• Dual Sensing Control
• Large capacity ODU (Up to 26HP)
• Continuous Heating ● ● ● ● ● ●
• Black Fin heat exchanger
• Heat pump or heat recovery function
• Flexible installation with
heat recovery unit and large capacity
• For large space, high rise building and
individual control building
● ● ●
● ● ● ● ● ● ●
HEAT PUMP
● ●
• Dual Sensing Control
• Large capacity ODU (Up to 32HP)
• Continuous Heating
• Black Fin heat exchanger ● ● ● ● ● ●
• Heat pump function
• For large space, high rise building and
individual control building
Unit : HP / ● 380V, 3Ø
34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 .... 104
● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ●
024 / 025
LINE-UP
○ ○ ○ ○
• Space saving
• Flexible design applications ○● ○●
- Slim, light, and broad range (4 - 12 HP)
- Large number of connectable indoor units
(Up to 20 Units)
• For small / medium building
● ● ●
○
HEAT RECOVERY
● ● ● ●
● ●
HEAT PUMP / HEAT RECOVERY
• High efficiency system regardless external conditions
• Indoor installation
• Low noise operation (No fan)
• For water-sourced system, high rise building and
building with aesthetic requirements.
• Simultaneous cooling and heating
• Minimized energy cost by water sourced
heat recovery system
• For individual control building
Unit : HP / ○ 220V, 1Ø / ● 380V, 3Ø
22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 .... 96
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
026 / 027
OUTDOOR
UNITS
INNOVATIVE TECHNOLOGIES
Dual Sensing Smart Load Control (SLC) Energy Savings with Dual Sensing Control
Enhanced energy saving & increased indoor comfort (Temperature & Humidity)
Cooling loads vary according to both temperature and humidity. Case study
With Dual Sensing SLC, work exerted to meet the load depends
Weather characteristics of Warsaw, Poland
on both temperature and humidity. As a result, less capacity will be
The portion of cooling operation hours at low humidity condition (Below
required in lower humidity conditions.
50% RH) is big. The cooling load of this condition is less than the load at
It influences the VRF system main processor’s decision on where to standard (50 ~ 70% RH) or high (over 70% RH) humidity condition even in
set the system’s target high or low system pressure values. the same outdoor air temperature. MULTI V 5 raises the evaporating Temp
up at low load (Low humidity) condition to enable energy saving and prevent
over-cooling which can happen when the system is controlled only by using
Smart Load Control responds to : outdoor air Temp.
1) Outdoor ambient dry bulb temperature
Warsaw weather in Summer
2) Outdoor ambient relative humidity (when enabled)
90%
Cooling Indoor Units - adjusts target low pressure
80% High Humidity
Raises the target low pressure value as cooling load falls and/or ambient temperature falls.
70% ~ 100%
Lowers the target low pressure value as cooling load rises and/or ambient temperature rises.
Relative Humidity
70%
Heating Indoor Units - adjusts target high pressure Mid Humidity Dual
60% SLC Sensing
Lowers the target high pressure as heating load falls and/or ambient temperature rises. 50% ~ 70%
SLC
Raises the target high pressure as heating load rises and/or ambient temperature falls. 50%
Low Humidity
40% 0% ~ 50%
What are the benefits?
30%
Enhanced energy savings 20%
- Cooling Mode 23°C 25°C 27°C 29°C 31°C 33°C 35°C
By raising the target low pressure during off-peak cooling operation, the Source : Outdoor Air Temperature
https://energyplus.net/weather
compressor lift is reduced. This slows compressor’s speed which leads to a
decrease in compressor’s power consumption. Time Portion of Relative Humidity in Summer
(Warsaw, Poland)
- Heating Mode
RH (%) Portion
By lowering the target high pressure during off-peak heating operation, the
compressor lift is reduced. This slows compressor’s speed which leads to a 70% ~ 100% 8%
Cooling Load
EER
MULTI V 5 SLC
MULTI V 5 Dual Sensing SLC 9.4 9.4
9.2
9.0
8.1 8.6
25°C 30°C 35°C Temperature 40% 60% 80% Relative 7.9
Humidity
Latent heat load Sensible heat load 6.9 6.9
※ Constant indoor temp condition 6.0
Cooling Load
Previous Cooling Capacity
Comfort &
Repeated on & off
Continuous Cooling
Dew Frost accumulation
Point (°C)
Indoor temp
LG Intelligent Defrost /
Smart Heating
Frost
Not cool accumulation begins
zone Coil
Surface (°C)
Dew
Point (°C)
Comfort
zone Set
temperature Additional Time
Spent Heating
Too cool
zone ※ Increased heating operation time per day : Up to 17%
• LG Internal Test result,
• Test condition (MULTI V 5 vs MULTI V IV, 22HP)
Previous Model Time - Outdoor : 2/1°C, Indoor : 20/15°C
- Humidity : 83%, Dew Point : -0.5°C
030 / 031
OUTDOOR UNITS _ MULTI V 5 _ KEY FEATURES
INNOVATIVE TECHNOLOGIES
Variable Path Heat Exchanger Active Refrigerant Control
Optimized system efficiency & continuous heating Stable operation & sustaining most efficient operation
MULTI V 5 outdoor units (ODU) are manufactured with horizontally The accumulator in the outdoor unit has a storage tank mounted
split ODU coil consisting of two independent circuit sections. inside known as the receiver tank. The receiver tank is equipped
Each half of the coil is independently controlled. with inlet and outlet valves that are electronically opened and
This split coil feature makes it possible for MULTI V 5 to provide closed. Refrigerant is being passed between the accumulator
continuous heating during defrost. The split coil and valve and the receiver tank on a continuous basis. MULTI V 5 active
arrangement also makes it possible for the MULTI V 5 to change refrigerant control algorithm goal is to minimize the amount of
the flow path of refrigerant through one of the two coils only, or refrigerant in circulation. The lower the volume in circulation the
through both coils in either a series or parallel arrangement. lower the cost to move it around the system and the higher the
Based on system pressures, ambient temperature conditions, and stability of the refrigeration cycle. It accomplishes this by constantly
mode of operation, the system controller may modify the selected monitoring the system operating pressures and temperatures and
path at any time. a variety of other vital control metrics of the refrigeration cycle.
When the cycle is out of balance, an adjustment in the amount of
circulating refrigerant occurs.
What are the benefits?
Optimizes system efficiency regardless of operating modes as ambient weather
conditions change. What are the benefits?
Customizes the used area of the outdoor unit’s heat exchange surface.
Widens the ambient temperature range at which stable operation occurs.
Low ambient cooling and / or light building load Sustains most efficient system operation regardless of outdoor weather
conditions, operating mode, or building load.
• Half active
• Lower idle
Cooling Heating Part Load
Amount of refrigerant
Full load cooling in receiver
• Upper & lower active
• Series circuited
• High velocity refrigerant flow
Efficiency
Heating
Heating
efficiency 3%
Part load
efficiency 10%
On Heating supply On
Cooling
efficiency
Time Active Refrigerant Control
Non-Partial defrost Refrigerant quantity (kg)
INNOVATIVE TECHNOLOGIES
HiPORTM Sub-cooling & Vapor Injection
Advanced compressor reliability & efficiency Increased heating performance
HiPOR™ is an LG trademark that stands for High Pressure Oil Return. MULTI V 5 is equipped with advanced sub-cooler and vapor injection
It consists of an oil separator, oil drain line between the separator and the control system. The sub-cooler algorithm sub-cools liquid refrigerant
compressor. HiPOR™ technology enables oil to return directly into the just enough so that it can travel to the farthest IDU in the system
compressor, instead of returning through the refrigerant suction pipe. operating in cooling mode without changing state. During low
This prevents energy waste when oil flows between the separator ambient operation down to -25°C (Heating mode), the sub-cooler
and the compressor. Because the operating pressure in the chamber provides medium temperature refrigerant gas to the compressor’s
containing the oil sump of the compressor and the pressure in the oil vapor injection system. When injected into the compression
separator are nearly equal, there is no loss in compressor efficiency. chamber, system mass flow increases which stabilizes the system’s
suction pressure. In all cases the vapor injection increases the
What are the benefits? compressors cycle efficiency and reduces operating cost.
Maximizes reliability and efficiency of the compressor.
Non HiPOR™ HiPOR™ What are the benefits?
1 Refrigerant
Compressor Provides stable refrigeration cycle operation over a wide range of outdoor
3 ambient operating conditions.
4
Increases compressor efficiency when compared to systems without vapor
Efficiency Increase injection technology.
Up to 33%
2
Oil Oil
Non heating Non heating Non-Vapor Injection
Time
27%
Timed oil return logic (Non-oil Sensor) Oil Level Sensor Oil
032 / 033
OUTDOOR UNITS _ MULTI V 5 _ KEY FEATURES
INNOVATIVE TECHNOLOGIES
Corrosion Resistance Black Fin Biomimetic Fan
Improved durability Maximized performance
The black coating with enhanced epoxy resin is applied on the heat The fans in MULTI V 5's outdoor unit have been upgraded to feature
exchanger for strong protection from various corrosive external a moire pattern similar to that of a clam shell's exterior that help with
conditions such as salt contamination and air pollution. noise reduction. At the same time, unlike the fans installed in previous
Moreover, the hydrophilic film keeps water from accumulating products that generate separation of flow due to absence of tubercles,
on the heat exchanger’s fin, minimizing moisture buildup and the bumpy back design inspired by the bumps on the humpback
eventually making it even more corrosion resistant. whale’s flipper is applied as the tubercles on the back side of the fans,
LG Corrosion Resistance solution passed ISO 21207 accelerated increasing wind power by reducing flacking. In addition to the biomimetic
corrosion test conducted by an independent test organization technology-based fans, extended shroud of MULTI V 5 allows more high
and the result has been certified by prestigious global certification static pressure and helps fans to blow higher air volume for efficient
organization, TUV. operation. With wider air guide, discharged air current is stabilized and
noise level is reduced.
What are the benefits?
This improvement in durability prolongs the product’s lifespan and lowers both What are the benefits?
the operational and maintenance costs. Based on the biomimetic technology, the fans of MULTI V 5 increased air
flow rate by 10% in comparison to previous model and reduced its power
consumption up to 20% when compared with the fan blade design on
MULTI V IV. This eventually results in maximized performance with large capacity.
1,950 hr
Process
1,000 hr
Fog1)
repeated
(35°C, 24hr)
95%
Test process is conducted according to ISO 9227. Gold Fin Black Fin
1) Salty water concentration : NaCl aqueous solution (5%) 100% copper material to Air flow rate Power consumption
prevent corrosion & refrigerant
leakage m /min
3
W
※ Comparison basis : 1 Rows of outdoor units 728kW (72.8kW x 10sets) installation case
Slave 1 Master
Outdoor unit Outdoor unit
Wider Operation Range
2 pipes Able to operate at extreme conditions
Liquid Pipe
With improved inverter cooling technology, sub-cooling and vapor
Gas Pipe injection, MULTI V 5 offers an extended range of heating and cooling
operations. It can perform normal heating operations at temperatures
Indoor unit
as low as -25°C. Cooling operations function at temperatures as low as
Changeover
18°C
15°C
-20°C
-25°C
10°C 15°C 20°C 27°C
Previous Model
034 / 035
OUTDOOR UNITS _ MULTI V 5 _ KEY FEATURES
USER-FRIENDLY CONTROL
Low-Noise Operation Simple Test Run via LGMV
For noise sensitive environment Increased overall efficiency in installation
Unlike the previous model which enables Low-Noise Operation To make sure that the product functions properly, conducting a test run
only during night after judgment time, the Low-Noise Operation of is recommended. For previous product, professional engineer who is well-
MULTI V 5 can function regardless of the time at the noise sensitive aware of more than 40 different functional settings and more than 200
areas. When used, the speed of the outdoor unit fans is restricted error codes had to check main parts in order to make sure that the test
during normal operation. run had succeeded. With Mobile LGMV of MULTI V 5, fast and accurate
auto test run can be executed and the professional installer running the
Previous Model test can receive test results via email, which shortens installation hours
and increases overall efficiency in installation processes.
Previous
Load
On
Load
Low-noise Low-noise
operation operation Wi-Fi MV Module
On Off On
LGMV
$%&'(!)!*! "#$%&&'!()*$+
+,-!./%01!2343&5
OUTDOOR UNITS _ MULTI V 5 _ TECHNICAL DATA
+,-+!./%01!67355%73!2343&
%&'()!*!$!
%&'()!*!$! "#$%&&'!()*$+
"#$%&&'!()*$+
Position of Sound Pressure Level Measuring Cooling / Heating Operation
!!!
+,!-./01()23!4)5)(6
+,!-./01()23!4)5)(6
!"#$
722')38!9!:/1()38!-./01()23
722')38!9!:/1()38!-./01()23
Cooling Heating
1 23$3!*+!435*%!3$!6'77!6*75%!8&)%*$*&)
1 23$3!*+!435*%!3$!)&9*)35!&:7'3$*);!8&)%*$*&)
50°C 20°C
48°C 18°C
1 <&#)%!57475!=*55!43'>!%7:7)%*);!&)!3!'3);7!&6!
45°C
15°C
638$&'+!+#8?!3+!$?7!8&)+$'#8$*&).38&#+$*8!
!
!
10°C
!
!
5°C
L9
1 <&#)%!57475!83)!@7!*)8'73+7%!*)!+$3$*8!
!
!
25°C
:'7++#'7!9&%7!&'!#+7%!3*'!;#*%7B
20°C
0°C
• Sound level can be increased in static pressure mode or used air guide.
/K(JLCCIHGE EFBC EDBC -20°C
-5°C
-10°C
/K(JLNCIHGE EDBC MCBC -25°C
-15°C
/K(JLOCIHGE MCBC 10°C 14°C 15°C 20°C 25°C 27°C 30°CMLBC 10°C 15°C 20°C 25°C27°C 30°C
Outdoor Units Function
/K(JLMCIHGE MCBE !!! !!!
Indoor Temperature (°C WB) MLBE Indoor Temperature (°C DB)
Category Functions MULTI V 5 !"#$!"#$
/K(JLFCIHGE MLBC ,- ,-./0+0!1*2#'0+!3++#40!$/0!1&55&6*)2!&70'3$*)2!8&)%*$*&)+9
./0+0!1*2#'0+!3++#40!$/0!1&55&6*)2!&70'3$*)2!8&)%*$*&)+9 MNBC
Variable Path of Outdoor Unit HEX ○ Note
/K(JNCHiPOR CIHGTME(High Pressure Oil Return) ○
MNBC :;#*<350)$!7*7*)2!50)2$/9=->4
:;#*<350)$!7*7*)2!50)2$/9=->4
1. These figures assume the following operating
?0<05!%*110'0)809@4
?0<05!%*110'0)809@4
MOBEconditions :
Equivalent piping length : 7.5m
/K(JNNHumidity
Key Refrigerant CIHGESensor ○ MOBE
A- A-B3)20!&1!7#55!%&6)!&70'3$*&)9
B3)20!&1!7#55!%&6)!&70'3$*&)9
Level difference : 0m MEBE
Components C1!$/0!'053$*<0!/#4*%*$D!*+!$&&!/*2/E!8&&5*)2!83738*$D!83)!F0!%08'03+0%!FD!$/0!+0)+*F50!/03$!'0%#8$*&)-
C1!$/0!'053$*<0!/#4*%*$D!*+!$&&!/*2/E!8&&5*)2!83738*$D!83)!F0!%08'03+0%!FD!$/0!+0)+*F50!/03$!'0%#8$*&)-
2. Range of pull down operation :
/K(JNOCorrosion
CIHGE Resistance Black Fin ○ MEBC
! !
○ !"#$%&'()*+,#-*.*)/
Simultaneous
!"#$%&'()*+,#-*.*)/ Cooling / Heating Operation
/K(JQC(Fan
Useful Function CIHreverse
GE rotation) MQBL MOBL
Indoor Cooling Comfort Mode Based 7*.34)(,&+3/#8++4*,9#:#;&()*,9#$%&'()*+,
Cooling
/K(JQNOutdoor CIHGETemperature ○ MQBF 7*.34)(,&+3/#8++4*,9#:#;&()*,9#$%&'()*+,
MEBFHeating
/K(JQOSmart CIHGLoadE Control (SLC) MEBM 30°C
MMBM 20°C
(Changing indoor discharge air ○
/K(JQMtemperature
CIHGE according to load) MMBC MPBF
/K(JQFOutdoorCIHGEUnit Control Refer to Humidity ○ MMBN MFBC 16°C
25°C
!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!"#$
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!"#$
!
15°C
/K(JOCDefrostCIHGE / Deicing ○ MMBQ 20°C MFBL
Range for continuous operation
!
Phase Protection ○
!
!
/K(JOORestartCIHGE MMBF MFBD
!
Reliability Delay (3-minutes) ○ 10°C
/K(JOMSelf CIHDiagnosis
GE ○ MPBF MDBQ 5°C
/K(JOFSoft CIHStart
GE ○ MFBC
5°C
PCBC
/K(JECTest CIHRunGEFunction ○ MPBC 0°C MFBM 0°C
/K(JENCIHG(Simple
AC Ez E Controller) MPBL
PQCSZ250S0
-5°C MFBP
AC Ez Touch PACEZA000
/K(JEOCIHGE MPBN MFBF -5°C
Central Controller AC Smart 5 PACS5A000 -10°C
/K(JEMACP CIH(Advanced
GE Control Platform) 5 PACP5A000
MPBO MDBE
/K(JEFAC CIManager
HGE 5 PACM5A000MFBQ -15°C
10°C 14°C 15°C 20°C 25°C 27°C 30°C
MDBF -10°C
/K(JMCACP
BNU (Building CIHLonworks
GE PLNWKB000MFBE PCBO 10°C 15°C 20°C 25°C27°C 30°C
/K(JMNACP
Network Unit)
CIHBACnet
GE MFBM
PQNFB17C0 Indoor Temperature (°C WB) PCBE Indoor Temperature (°C DB)
!!!
!"#$
!!!
!"#$
Installation/K(JMORefrigerant
CIHGE Charging Kit PRAC1
MFBP ,- ,- ./0+0!1*2#'0+!3++#40!$/0!1&55&6*)2!&70'3$*)2!8&)%*$*&)+9
./0+0!1*2#'0+!3++#40!$/0!1&55&6*)2!&70'3$*)2!8&)%*$*&)+9
Note
:;#*<350)$!7*7*)2!50)2$/9=->4
PCBM
Variable Water Flow Valve Control Kit - :;#*<350)$!7*7*)2!50)2$/9=->4
/K(JMMCIHGE MFBF 1.?0<05!%*110'0)809@4
These figures assume the following operating
?0<05!%*110'0)809@4 PCBM conditions :
PDI (Power Standard PPWRDB000 A- A-
Equivalent piping length : 7.5m
B3)20!&1!7#55!%&6)!&70'3$*&)9
B3)20!&1!7#55!%&6)!&70'3$*&)9
Distribution/Indicator)
K(JMFPremium
CIHGE PQNUD1S40MDBC Level difference : 0m PLBL
C1!$/0!'053$*<0!/#4*%*$D!*+!$&&!/*2/E!8&&5*)2!83738*$D!83)!F0!%08'03+0%!FD!$/0!+0)+*F50!/03$!'0%#8$*&)-
C1!$/0!'053$*<0!/#4*%*$D!*+!$&&!/*2/E!8&&5*)2!83738*$D!83)!F0!%08'03+0%!FD!$/0!+0)+*F50!/03$!'0%#8$*&)-
2. Range of pull down operation :
Cool / Heat Selector CIHGE
/ K ( J P C MDBM PLcapacity
BQ can be decreased by the sensible heat
!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!"##
#010#010
036 / 037
HEAT RECOVERY
- Air cooled VRF Heat Pump & Heat Recovery
- 22.4kW ~ 268.8kW (Cooling capacity based)
- 3Ø, 380 ~ 415V, 50Hz
- Top discharge outdoor unit
- Ability to function as Heat Pump or Heat Recovery
Designed
Design
For
For
The Ultimate
The Ultimate
1,000m 225m
TOTAL PIPING LENGTH Longest Piping Length
Piping capabilities
110m
Actual longest piping length (Equivalent) !"":)P!!E:R
@-065/')=&=&06)4506'()+H'5,)#/')I,+07()P7-01&'&-0+4)+==4&7+'&-0R 40m (90m)
Height between ODU ~ IDU ##":
Height between IDU ~ IDU 40m
Height between ODU ~ ODU E:
Energy savings
Partial Defrost
Reliability
Interchangeable between
heat pump and heat recovery
Low noise
Type
Changeover
Advanced performance
038 / 039
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION
HP 8 10 12 14
Combination Unit ARUM080LTE5 ARUM100LTE5 ARUM120LTE5 ARUM140LTE5
Model Name
Independent Unit ARUM080LTE5 ARUM100LTE5 ARUM120LTE5 ARUM140LTE5
Cooling (Rated) kW 22.4 28.0 33.6 39.2
Btu/h 76,400 95,000 114,600 133,800
Heating (Rated) kW 22.4 28.0 33.6 39.2
Capacity
Btu/h 76,400 95,000 114,600 133,800
Heating (Max) kW 25.2 31.5 37.8 44.1
Btu/h 86,000 107,500 129,000 150,500
Cooling (Rated) kW 5.28 6.83 7.71 8.67
Input Heating (Rated) kW 3.97 4.92 6.85 8.13
Heating (Max) kW 4.78 5.92 8.26 9.72
COP Cooling (Rated) 4.24 4.10 4.36 4.52
Heating (Rated) 5.64 5.69 4.91 4.82
COP
Heating (Max) 5.27 5.32 4.58 4.54
SCOP 4.69 4.51 5.01 4.63
Exterior Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 1 (Inverter) x 1 (Inverter) x 1 (Inverter) x 1
Motor Output x
Compressor W x No. 4,200 x 1 5,300 x 1 5,300 x 1 5,300 x 1
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 3,900 3,900 3,900 3,900
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x
W x No. 1,200 x 1 1,200 x 1 1,200 x 1 900 x 2
Number
Fan Air Flow Rate (High) m3/min x No. 240 x 1 240 x 1 240 x 1 320 x 1
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) Ø9.52 (3/8) Ø9.52 (3/8) Ø12.7 (1/2) Ø12.7 (1/2)
Connections
Low Pressure Gas Pipe mm (inch) Ø19.05 (3/4) Ø22.2 (7/8) Ø28.58 (1-1/8) Ø28.58 (1-1/8)
for Heat
Recovery High Pressure Gas Pipe mm (inch) Ø15.88 (5/8) Ø19.05 (3/4) Ø19.05 (3/4) Ø22.2 (7/8)
Pipe Liquid Pipe mm (inch) Ø9.52 (3/8) Ø9.52 (3/8) Ø12.7 (1/2) Ø12.7 (1/2)
Connections
for Heat Pump Gas Pipe mm (inch) Ø19.05 (3/4) Ø22.2 (7/8) Ø28.58 (1-1/8) Ø28.58 (1-1/8)
Dimensions (W x H x D) mm x No. (930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x1
Dimensions (W x H x D) - Shipping mm x No. (960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1 (1,280 x 1,825 x 796) x 1
Net Weight kg x No. 198 x 1 215 x 1 215 x 1 237 x 1
Shipping Weight kg x No. 208 x 1 225 x 1 225 x 1 250 x 1
1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination (160% ~ 200%). The recommended ratio is 130%.
MULTI V 5 HEAT RECOVERY
ARUM160LTE5 / ARUM180LTE5
ARUM200LTE5 / ARUM220LTE5
HP 16 18 20 22
Combination Unit ARUM160LTE5 ARUM180LTE5 ARUM200LTE5 ARUM220LTE5
Model Name
Independent Unit ARUM160LTE5 ARUM180LTE5 ARUM200LTE5 ARUM220LTE5
Cooling (Rated) kW 44.8 50.4 56.0 61.6
Btu/h 152,900 172,000 191,000 210,200
Heating (Rated) kW 44.8 50.4 56.0 61.6
Capacity
Btu/h 152,900 172,000 191,000 210,200
Heating (Max) kW 50.4 56.7 63.0 69.3
Btu/h 172,000 193,000 215,000 236,500
Cooling (Rated) kW 10.90 11.03 12.76 15.92
Input Heating (Rated) kW 10.28 10.12 12.20 14.15
Heating (Max) kW 12.39 11.94 14.69 16.76
COP Cooling (Rated) 4.11 4.57 4.39 3.87
Heating (Rated) 4.36 4.98 4.59 4.35
COP
Heating (Max) 4.07 4.75 4.29 4.13
SCOP 4.83 4.0 3.98 3.9
Exterior Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 1 (Inverter) x 2 (Inverter) x 2 (Inverter) x 2
Motor Output x
Compressor W x No. 5,300 x 1 (5,300 x 1) + (4,200 x 1) (5,300 x 1) + (4,200 x 1) (5,300 x 1) + (4,200 x 1)
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 3,900 5,200 5,200 5,200
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x
W x No. 900 x 2 900 x 2 900 x 2 900 x 2
Number
Fan Air Flow Rate (High) m3/min x No. 320 x 1 320 x 1 320 x 1 320 x 1
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) Ø12.7 (1/2) Ø15.88 (5/8) Ø15.88 (5/8) Ø15.88 (5/8)
Connections
Low Pressure Gas Pipe mm (inch) Ø28.58 (1-1/8) Ø28.58 (1-1/8) Ø28.58 (1-1/8) Ø28.58 (1-1/8)
for Heat
Recovery High Pressure Gas Pipe mm (inch) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8) Ø28.58 (1-1/8)
Pipe Liquid Pipe mm (inch) Ø12.7 (1/2) Ø15.88 (5/8) Ø15.88 (5/8) Ø15.88 (5/8)
Connections
for Heat Pump Gas Pipe mm (inch) Ø28.58 (1-1/8) Ø28.58 (1-1/8) Ø28.58 (1-1/8) Ø28.58 (1-1/8)
Dimensions (W x H x D) mm x No. (1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1
Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 1 (1,280 x 1,825 x 796) x 1 (1,280 x 1,825 x 796) x 1 (1,280 x 1,825 x 796) x 1
Net Weight kg x No. 237 x 1 300 x 1 300 x 1 300 x 1
Shipping Weight kg x No. 250 x 1 312 x 1 312 x 1 312 x 1
Sound Cooling dB(A) 60.5 61.0 62.0 64.5
Pressure Level Heating dB(A) 61.5 62.0 64.5 65.5
Sound Cooling dB(A) 90.0 92.0 93.0 93.0
Power Level Heating dB(A) 94.0 95.0 96.0 97.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A R410A
Precharged Amount
kg 13.5 16.0 16.0 16.0
Refrigerant in Factory
t-CO2eq 28.2 33.4 33.4 33.4
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 26 (40) 29 (45) 32 (50) 35 (56)
1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination (160% ~ 200%). The recommended ratio is 130%.
040 / 041
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION
HP 24 26 22' 24'
Combination Unit ARUM240LTE5 ARUM260LTE5 ARUM221LTE5 ARUM241LTE5
Model Name ARUM120LTE5 ARUM120LTE5
Independent Unit ARUM240LTE5 ARUM260LTE5
ARUM100LTE5 ARUM120LTE5
Cooling (Rated) kW 67.2 72.8 61.6 67.2
Btu/h 229,300 248,400 210,200 229,300
Heating (Rated) kW 67.2 67.2 61.6 67.2
Capacity
Btu/h 229,300 248,400 210,200 229,300
Heating (Max) kW 74.3 74.3 69.3 75.6
Btu/ 253,400 253,400 236,500 257,900
Cooling (Rated) kW 17.41 20.20 14.54 15.41
Input Heating (Rated) kW 15.89 15.99 11.77 13.70
Heating (Max) kW 18.80 19.15 14.18 16.52
COP Cooling (Rated) 3.86 3.60 4.24 4.36
Heating (Rated) 4.23 4.20 5.23 4.91
COP
Heating (Max) 3.95 3.88 4.89 4.58
SCOP 4.34 4.34 - -
Exterior Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 2 (Inverter) x 2 (Inverter) x 2 (Inverter) x 2
Motor Output x
Compressor W x No. 5,300 x 2 5,300 x 2 5,300 x 2 5,300 x 2
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 5,200 5,200 7,800 7,800
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x
W x No. 900 x 2 900 x 2 (1,200 x 1) + (1,200 x 1) (1,200 x 1) + (1,200 x 1)
Number
Fan Air Flow Rate (High) m /min x No.
3
320 x 1 320 x 1 (240 x 1) + (240 x 1) (240 x 1) + (240 x 1)
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) Ø15.88 (5/8) Ø19.05 (3/4) Ø15.88 (5/8) Ø15.88 (5/8)
Connections
Low Pressure Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø28.58 (1-1/8) Ø34.9 (1-3/8)
for Heat
Recovery High Pressure Gas Pipe mm (inch) Ø28.58 (1-1/8) Ø28.58 (1-1/8) Ø28.58 (1-1/8) Ø28.58 (1-1/8)
Pipe Liquid Pipe mm (inch) Ø15.88 (5/8) Ø19.05 (3/4) Ø15.88 (5/8) Ø15.88 (5/8)
Connections
for Heat Pump Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø28.58 (1-1/8) Ø34.9 (1-3/8)
(930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1 +
Dimensions (W x H x D) mm x No. (1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1
(930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1
(960 x 1,825 x 796) x 1 + (960 x 1,825 x 796) x 1 +
Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 1 (1,280 x 1,825 x 796) x 1
(960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1
Net Weight kg x No. 310 x 1 310 x 1 (215 x 1) + (215 x 1) (215 x 1) + (215 x 1)
Shipping Weight kg x No. 320 x 1 320 x 1 (225 x 1) + (225 x 1) (225 x 1) + (225 x 1)
Sound Cooling dB(A) 65.0 65.0 61.5 62.0
Pressure Level Heating dB(A) 67.0 67.0 62.5 63.0
Sound Cooling dB(A) 95.0 95.0 88.5 89.0
Power Level Heating dB(A) 99.0 99.0 91.5 92.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A R410A
Precharged Amount
kg 17.0 17.0 19.0 19.0
Refrigerant in Factory
t-CO2eq 35.5 35.5 39.7 39.7
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 39 (61) 42 (64) 35 (44) 39 (48)
1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination (160% ~ 200%). The recommended ratio is 130%.
MULTI V 5 HEAT RECOVERY
ARUM261LTE5 / ARUM280LTE5
ARUM300LTE5 / ARUM320LTE5
HP 26' 28 30 32
Combination Unit ARUM261LTE5 ARUM280LTE5 ARUM300LTE5 ARUM320LTE5
Model Name ARUM140LTE5 ARUM160LTE5 ARUM180LTE5 ARUM200LTE5
Independent Unit
ARUM120LTE5 ARUM120LTE5 ARUM120LTE5 ARUM120LTE5
Cooling (Rated) kW 72.8 78.4 84.0 89.6
Btu/h 248,400 267,500 286,600 305,700
Heating (Rated) kW 72.8 78.4 84.0 89.6
Capacity
Btu/h 248,400 267,500 286,600 305,700
Heating (Max) kW 81.9 88.2 94.5 100.8
Btu/h 279,400 300,900 322,400 343,900
Cooling (Rated) kW 16.38 18.61 18.73 20.46
Input Heating (Rated) kW 14.98 17.13 16.97 19.05
Heating (Max) kW 17.98 20.65 20.20 22.95
COP Cooling (Rated) 4.44 4.21 4.48 4.38
Heating (Rated) 4.86 4.58 4.95 4.70
COP
Heating (Max) 4.56 4.27 4.68 4.39
SCOP - - - -
Exterior Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 2 (Inverter) x 2 (Inverter) x 3 (Inverter) x 3
Motor Output x
Compressor W x No. 5,300 x 2 5,300 x 2 (5,300 x 2) + (4,200 x 1) (5,300 x 2) + (4,200 x 1)
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 7,800 7,800 9,100 9,100
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x
W x No. (900 x 2) + (1,200 x 1) (900 x 2) + (1,200 x 1) (900 x 2) + (1,200 x 1) (900 x 2) + (1,200 x 1)
Number
Fan Air Flow Rate (High) m3/min x No. (320 x 1) + (240 x 1) (320 x 1) + (240 x 1) (320 x 1) + (240 x 1) (320 x 1) + (240 x 1)
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Connections
Low Pressure Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8)
for Heat
Recovery High Pressure Gas Pipe mm (inch) Ø28.58 (1-1/8) Ø28.58 (1-1/8) Ø28.58 (1-1/8) Ø28.58 (1-1/8)
Pipe Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Connections
for Heat Pump Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8)
(1,240 x 1,690 x 760) x 1 + (1,240 x 1,690 x 760) x 1 + (1,240 x 1,690 x 760) x 1 + (1,240 x 1,690 x 760) x 1 +
Dimensions (W x H x D) mm x No.
(930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1
(1,280 x 1,825 x 796) x 1 + (1,280 x 1,825 x 796) x 1 + (1,280 x 1,825 x 796) x 1 + (1,280 x 1,825 x 796) x 1 +
Dimensions (W x H x D) - Shipping mm x No.
(960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1
Net Weight kg x No. (237 x 1) + (215 x 1) (237 x 1) + (215 x 1) (300 x 1) + (215 x 1) (300 x 1) + (215 x 1)
Shipping Weight kg x No. (250 x 1) + (225 x 1) (250 x 1) + (225 x 1) (312 x 1) + (225 x 1) (312 x 1) + (225 x 1)
Sound Cooling dB(A) 62.5 62.8 63.1 63.8
Pressure Level Heating dB(A) 63.5 63.8 64.1 65.8
Sound Cooling dB(A) 90.8 91.5 93.0 93.8
Power Level Heating dB(A) 94.5 95.2 96.0 96.8
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A R410A
Precharged Amount
kg 23.0 23.0 25.5 25.5
Refrigerant in Factory
t-CO2eq 48.0 48.0 53.2 53.2
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 42 (52) 45 (56) 49 (60) 52 (64)
1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination (160% ~ 200%). The recommended ratio is 130%.
042 / 043
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION
HP 34 36 38 40
Combination Unit ARUM340LTE5 ARUM360LTE5 ARUM380LTE5 ARUM400LTE5
Model Name ARUM220LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
Independent Unit
ARUM120LTE5 ARUM120LTE5 ARUM140LTE5 ARUM160LTE5
Cooling (Rated) kW 95.2 100.8 106.4 112.0
Btu/h 324,800 343,900 363,000 382,100
Heating (Rated) kW 95.2 100.8 106.4 112.0
Capacity
Btu/h 324,800 343,900 363,000 382,100
Heating (Max) kW 107.1 112.1 118.4 124.7
Btu/h 365,400 382,300 403,800 425,300
Cooling (Rated) kW 23.62 25.12 26.08 28.31
Input Heating (Rated) kW 21.00 22.74 24.02 26.17
Heating (Max) kW 25.02 27.06 28.52 31.19
COP Cooling (Rated) 4.03 4.01 4.08 3.96
Heating (Rated) 4.53 4.43 4.43 4.28
COP
Heating (Max) 4.28 4.14 4.15 4.00
SCOP - - - -
Exterior Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 3 (Inverter) x 3 (Inverter) x 3 (Inverter) x 3
Motor Output x
Compressor W x No. (5,300 x 2) + (4,200 x 1) 5,300 x 3 5,300 x 3 5,300 x 3
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 9,100 9,100 9,100 9,100
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x
W x No. (900 x 2) + (1,200 x 1) (900 x 2) + (1,200 x 1) 900 x 4 900 x 4
Number
Fan Air Flow Rate (High) m3/min x No. (320 x 1) + (240 x 1) (320 x 1) + (240 x 1) 320 x 2 320 x 2
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Connections
Low Pressure Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8)
for Heat
Recovery High Pressure Gas Pipe mm (inch) Ø28.58 (1-1/8) Ø28.58 (1-1/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8)
Pipe Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Connections
for Heat Pump Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8)
(1,240 x 1,690 x 760) x 1 + (1,240 x 1,690 x 760) x 1 +
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 2 (1,240 x1,690 x 760) x 2
(930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1
(1,280 x 1,825 x 796) x 1 + (1,280 x 1,825 x 796) x 1 +
Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 2 (1,280 x 1,825 x 796) x 2
(960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1
Net Weight kg x No. (300 x 1) + (215 x 1) (310 x 1) + (215 x 1) (310 x 1) + (237 x 1) (310 x 1) + (237 x 1)
Shipping Weight kg x No. (312 x 1) + (225 x 1) (320 x 1) + (225 x 1) (320 x 1) + (250 x 1) (320 x 1) + (250 x 1)
Sound Cooling dB(A) 65.6 66.0 66.2 66.3
Pressure Level Heating dB(A) 66.6 67.8 68.0 68.1
Sound Cooling dB(A) 93.8 95.5 96.0 96.2
Power Level Heating dB(A) 97.6 99.4 100.0 100.2
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A R410A
Precharged Amount
kg 25.5 26.5 30.5 30.5
Refrigerant in Factory
t-CO2eq 53.2 55.3 63.7 63.7
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 55 (64) 58 (64) 61 (64) 64
1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination (160% ~ 200%). The recommended ratio is 130%.
MULTI V 5 HEAT RECOVERY
ARUM420LTE5 / ARUM440LTE5
ARUM460LTE5 / ARUM480LTE5
HP 42 44 46 48
Combination Unit ARUM420LTE5 ARUM440LTE5 ARUM460LTE5 ARUM480LTE5
Model Name ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
Independent Unit
ARUM180LTE5 ARUM200LTE5 ARUM220LTE5 ARUM240LTE5
Cooling (Rated) kW 117.6 123.2 128.8 134.4
Btu/h 401,300 420,400 439,500 458,600
Heating (Rated) kW 117.6 123.2 128.8 134.4
Capacity
Btu/h 401,300 420,400 439,500 458,600
Heating (Max) kW 131.0 137.3 143.6 148.5
Btu/h 446,800 468,300 489,800 506,700
Cooling (Rated) kW 28.44 30.17 33.33 34.82
Input Heating (Rated) kW 26.01 28.09 30.04 31.78
Heating (Max) kW 30.74 33.49 35.56 37.60
COP Cooling (Rated) 4.14 4.08 3.86 3.86
Heating (Rated) 4.52 4.39 4.29 4.23
COP
Heating (Max) 4.26 4.10 4.04 3.95
SCOP - - - -
Exterior Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 4 (Inverter) x 4 (Inverter) x 4 (Inverter) x 4
Motor Output x
Compressor W x No. (5,300 x 3) + (4,200 x 1) (5,300 x 3) + (4,200 x 1) (5,300 x 3) + (4,200 x 1) 5,300 x 4
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 10,400 10,400 10,400 10,400
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x
W x No. 900 x 4 900 x 4 900 x 4 900 x 4
Number
Fan Air Flow Rate (High) m /min x No.
3
320 x 2 320 x 2 320 x 2 320 x 2
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Connections
Low Pressure Gas Pipe mm (inch) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8)
for Heat
Recovery High Pressure Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8)
Pipe Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Connections
for Heat Pump Gas Pipe mm (inch) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8)
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 2 (1,240 x1,690 x 760) x 2 (1,240 x1,690 x 760) x 2 (1,240 x1,690 x 760) x 2
Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 2 (1,280 x 1,825 x 796) x 2 (1,280 x 1,825 x 796) x 2 (1,280 x 1,825 x 796) x 2
Net Weight kg x No. (310 x 1) + (300 x 1) (310 x 1) + (300 x 1) (310 x 1) + (300 x 1) 310 x 2
Shipping Weight kg x No. (320 x 1) + (312 x 1) (320 x 1) + (312 x 1) (320 x 1) + (312 x 1) 320 x 2
Sound Cooling dB(A) 66.5 66.8 67.8 68.0
Pressure Level Heating dB(A) 68.2 68.9 69.3 70.0
Sound Cooling dB(A) 96.8 97.1 97.1 98.0
Power Level Heating dB(A) 100.5 100.8 101.1 102.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A R410A
Precharged Amount
kg 33.0 33.0 33.0 34.0
Refrigerant in Factory
t-CO2eq 68.9 68.9 68.9 71.0
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 64 64 64 64
1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination (160% ~ 200%). The recommended ratio is 130%.
044 / 045
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION
HP 50 52 54 56
Combination Unit ARUM500LTE5 ARUM520LTE5 ARUM540LTE5 ARUM560LTE5
Model Name ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
Independent Unit ARUM140LTE5 ARUM160LTE5 ARUM180LTE5 ARUM200LTE5
ARUM120LTE5 ARUM120LTE5 ARUM120LTE5 ARUM120LTE5
Cooling (Rated) kW 140 145.6 151.2 156.8
Btu/h 477,700 496,800 515,900 535,000
Heating (Rated) kW 140 145.6 151.2 156.8
Capacity
Btu/h 477,700 496,800 515,900 535,000
Heating (Max) kW 156.2 162.5 168.8 175.1
Btu/h 532,800 554,300 575,800 597,300
Cooling (Rated) kW 33.79 36.02 36.14 37.87
Input Heating (Rated) kW 30.87 33.02 32.86 34.94
Heating (Max) kW 36.78 39.45 39 41.75
COP Cooling (Rated) 4.14 4.04 4.18 4.14
Heating (Rated) 4.54 4.41 4.6 4.49
COP
Heating (Max) 4.25 4.12 4.33 4.19
SCOP - - - -
Exterior Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 4 (Inverter) x 4 (Inverter) x 5 (Inverter) x 5
Motor Output x
Compressor W x No. 5,300 x 4 5,300 x 4 (5,300 x 4) + (4,200 x 1) (5,300 x 4) + (4,200 x 1)
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 13,000 13,000 14,300 14,300
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x
W x No. (900 x 4) + (1,200 x 1) (900 x 4) + (1,200 x 1) (900 x 4) + (1,200 x 1) (900 x 4) + (1,200 x 1)
Number
Fan Air Flow Rate (High) m3/min x No. (320 x 2) + (240 x 1) (320 x 2) + (240 x 1) (320 x 2) + (240 x 1) (320 x 2) + (240 x 1)
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Connections
Low Pressure Gas Pipe mm (inch) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8)
for Heat
Recovery High Pressure Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8)
Pipe Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Connections
for Heat Pump Gas Pipe mm (inch) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8)
(1,240 x 1,690 x 760) x 2 + (1,240 x 1,690 x 760) x 2 + (1,240 x 1,690 x 760) x 2 + (1,240 x 1,690 x 760) x 2 +
Dimensions (W x H x D) mm x No.
(930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1
(1,280 x 1,825 x 796) x 2 + (1,280 x 1,825 x 796) x 2 + (1,280 x 1,825 x 796) x 2 + (1,280 x 1,825 x 796) x 2 +
Dimensions (W x H x D) - Shipping mm x No.
(960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1
(310 x 1) + (237 x 1) + (215 (310 x 1) + (237 x 1) + (215 (310 x 1) + (300 x 1) + (310 x 1) + (300 x 1) +
Net Weight kg x No.
x 1) x 1) (215 x 1) (215 x 1)
(320 x 1) + (250 x 1) + (320 x 1) + (250 x 1) + (320 x 1) + (312 x 1) + (320 x 1) + (312 x 1) +
Shipping Weight kg x No.
(225 x 1) (225 x 1) (225 x 1) (225 x 1)
Sound Cooling dB(A) 67 67.1 67.2 67.4
Pressure Level Heating dB(A) 68.6 68.7 68.8 69.5
Sound Cooling dB(A) 96.4 96.6 97.1 97.4
Power Level Heating dB(A) 100.3 100.5 100.8 101
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A R410A
Precharged Amount
kg 40 40 42.5 42.5
Refrigerant in Factory
t-CO2eq 83.5 83.5 88.7 88.7
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 64 64 64 64
1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination (160% ~ 200%). The recommended ratio is 130%.
MULTI V 5 HEAT RECOVERY
ARUM580LTE5 / ARUM600LTE5
ARUM620LTE5 / ARUM640LTE5
ARUM660LTE5
HP 58 60 62 64 66
Combination Unit ARUM580LTE5 ARUM600LTE5 ARUM620LTE5 ARUM640LTE5 ARUM660LTE5
Model Name ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
Independent Unit ARUM220LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
ARUM120LTE5 ARUM120LTE5 ARUM140LTE5 ARUM160LTE5 ARUM180LTE5
Cooling (Rated) kW 162.4 168.0 173.6 179.2 184.8
Btu/h 554,100 573,200 592,300 611,400 630,500
Heating (Rated) kW 162.4 168.0 173.6 179.2 184.8
Capacity
Btu/h 554,100 573,200 592,300 611,400 630,500
Heating (Max) kW 181.4 186.3 192.6 198.9 205.2
Btu/h 618,800 635,700 657,200 678,700 700,200
Cooling (Rated) kW 41.03 42.53 43.49 45.72 45.85
Input Heating (Rated) kW 36.89 38.63 39.91 42.06 41.90
Heating (Max) kW 43.82 45.86 47.32 49.99 49.54
COP Cooling (Rated) 3.96 3.95 3.99 3.92 4.03
Heating (Rated) 4.40 4.35 4.35 4.26 4.41
COP
Heating (Max) 4.14 4.06 4.07 3.98 4.14
SCOP - - - - -
Exterior Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus /
Heat Exchanger Type
Black Fin Black Fin Black Fin Black Fin Black Fin
Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed
Type
Scroll Scroll Scroll Scroll Scroll
Combination x No. (Inverter) x 5 (Inverter) x 5 (Inverter) x 5 (Inverter) x 5 (Inverter) x 6
Compressor Motor Output x
W x No. (5,300 x 4) + (4,200 x 1) 5,300 x 5 5,300 x 5 5,300 x 5 (5,300 x 5) + (4,200 x 1)
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 14,300 14,300 14,300 14,300 15,600
Type Propeller fan Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x
W x No. (900 x 4) + (1,200 x 1) (900 x 4) + (1,200 x 1) 900 x 6 900 x 6 900 x 6
Number
Fan Air Flow Rate (High) m3/min x No. (320 x 2) + (240 x 1) (320 x 2) + (240 x 1) 320 x 3 320 x 3 320 x 3
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8)
Connections
Low Pressure Gas Pipe mm (inch) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø53.98 (2-1/8)
for Heat
Recovery High Pressure Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø41.3 (1-5/8)
Pipe Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8)
Connections
for Heat Pump Gas Pipe mm (inch) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø53.98 (2-1/8)
(1,240 x 1,690 x 760) x 2 (1,240 x 1,690 x 760) x 2
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 3 (1,240 x1,690 x 760) x 3 (1,240 x1,690 x 760) x 3
+ (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1
(1,280 x 1,825 x 796) x 2 (1,280 x 1,825 x 796) x 2
Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3
+ (960 x 1,825 x 796) x 1 + (960 x 1,825 x 796) x 1
(310 x 1) + (300 x 1) +
Net Weight kg x No. (310 x 2) + (215 x 1) (310 x 2) + (237 x 1) (310 x 2) + (237 x 1) (310 x 2) + (300 x 1)
(215 x 1)
(320 x 1) + (312 x 1) +
Shipping Weight kg x No. (320 x 2) + (225 x 1) (320 x 2) + (250 x 1) (320 x 2) + (250 x 1) (320 x 2) + (312 x 1)
(225 x 1)
Sound Cooling dB(A) 68.3 68.5 68.6 68.7 68.8
Pressure Level Heating dB(A) 69.8 70.4 70.5 70.6 70.6
Sound Cooling dB(A) 97.4 98.3 98.5 98.6 99.0
Power Level Heating dB(A) 101.4 102.2 102.5 102.6 102.8
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A R410A R410A
Precharged Amount
kg 42.5 43.5 47.5 47.5 50.0
in Factory
Refrigerant
t-CO2eq 88.7 90.8 99.2 99.2 104.4
Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion
Control
Valve Valve Valve Valve Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 64 64 64 64 64
1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination (160% ~ 200%). The recommended ratio is 130%.
046 / 047
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION
HP 68 70 72 74 76
Combination Unit ARUM680LTE5 ARUM700LTE5 ARUM720LTE5 ARUM740LTE5 ARUM760LTE5
ARUM240LTE5 ARUM240LTE5
Model Name ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
ARUM240LTE5 ARUM240LTE5
Independent Unit ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
ARUM140LTE5 ARUM160LTE5
ARUM200LTE5 ARUM220LTE5 ARUM240LTE5
ARUM120LTE5 ARUM120LTE5
Cooling (Rated) kW 190.4 196.0 201.6 207.2 212.8
Btu/h 649,600 668,800 687,900 707,000 726,100
Heating (Rated) kW 190.4 196.0 201.6 207.2 212.8
Capacity
Btu/h 649,600 668,800 687,900 707,000 726,100
Heating (Max) kW 211.5 217.8 222.8 230.4 236.7
Btu/h 721,700 743,200 760,100 786,200 807,700
Cooling (Rated) kW 47.57 50.74 52.23 51.20 53.43
Input Heating (Rated) kW 43.98 45.93 47.67 46.76 48.91
Heating (Max) kW 52.29 54.36 56.40 55.58 58.25
COP Cooling (Rated) 4.00 3.86 3.86 4.05 3.98
Heating (Rated) 4.33 4.27 4.23 4.43 4.35
COP
Heating (Max) 4.05 4.01 3.95 4.15 4.06
SCOP - - - - -
Exterior Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus /
Heat Exchanger Type
Black Fin Black Fin Black Fin Black Fin Black Fin
Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed
Type
Scroll Scroll Scroll Scroll Scroll
Combination x No. (Inverter) x 6 (Inverter) x 6 (Inverter) x 6 (Inverter) x 6 (Inverter) x 6
Compressor Motor Output x
W x No. (5,300 x 5) + (4,200 x 1) (5,300 x 5) + (4,200 x 1) 5,300 x 6 5,300 x 6 5,300 x 6
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 15,600 15,600 15,600 18,200 18,200
Type Propeller fan Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x
W x No. 900 x 6 900 x 6 900 x 6 (900 x 6) + (1,200 x 1) (900 x 6) + (1,200 x 1)
Number
Fan Air Flow Rate (High) m3/min x No. 320 x 3 320 x 3 320 x 3 (320 x 3) + (240 x 1) (320 x 3) + (240 x 1)
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8)
Connections
Low Pressure Gas Pipe mm (inch) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8)
for Heat
Recovery High Pressure Gas Pipe mm (inch) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8)
Pipe Liquid Pipe mm (inch) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8)
Connections
for Heat Pump Gas Pipe mm (inch) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8)
(1,240 x 1,690 x 760) x 3 (1,240 x 1,690 x 760) x 3
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 3 (1,240 x1,690 x 760) x 3 (1,240 x1,690 x 760) x 3
+ (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1
(1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3
Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3
+ (960 x 1,825 x 796) x 1 + (960 x 1,825 x 796) x 1
(310 x 2) + (237 x 1) + (310 x 2) + (237 x 1) +
Net Weight kg x No. (310 x 2) + (300 x 1) (310 x 2) + (300 x 1) 310 x 3
(215 x 1) (215 x 1)
(320 x 2) + (250 x 1) + (320 x 2) + (250 x 1) +
Shipping Weight kg x No. (320 x 2) + (312 x 1) (320 x 2) + (312 x 1) 320 x 3
(225 x 1) (225 x 1)
Sound Cooling dB(A) 69.0 69.6 69.8 69.1 69.2
Pressure Level Heating dB(A) 71.1 71.3 71.8 70.9 70.9
Sound Cooling dB(A) 99.2 99.2 99.8 98.8 98.9
Power Level Heating dB(A) 103.0 103.2 103.8 102.7 102.8
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A R410A R410A
Precharged Amount
kg 50.0 50.0 51.0 57.0 57.0
in Factory
Refrigerant
t-CO2eq 104.4 104.4 106.5 119.0 119.0
Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion
Control
Valve Valve Valve Valve Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 64 64 64 64 64
1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination (160% ~ 200%). The recommended ratio is 130%.
MULTI V 5 HEAT RECOVERY
ARUM780LTE5 / ARUM800LTE5
ARUM820LTE5 / ARUM840LTE5
ARUM860LTE5
HP 78 80 82 84 86
Combination Unit ARUM780LTE5 ARUM800LTE5 ARUM820LTE5 ARUM840LTE5 ARUM860LTE5
ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
Model Name ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
Independent Unit
ARUM180LTE5 ARUM200LTE5 ARUM220LTE5 ARUM240LTE5 ARUM240LTE5
ARUM120LTE5 ARUM120LTE5 ARUM120LTE5 ARUM120LTE5 ARUM140LTE5
Cooling (Rated) kW 218.4 224.0 229.6 235.2 240.8
Btu/h 745,200 764,300 783,400 802,500 821,600
Heating (Rated) kW 218.4 224.0 229.6 235.2 240.8
Capacity
Btu/h 745,200 764,300 783,400 802,500 821,600
Heating (Max) kW 243.0 249.3 255.6 260.6 266.9
Btu/h 829,200 850,700 872,100 889,100 910,600
Cooling (Rated) kW 53.55 55.28 58.44 59.93 60.90
Input Heating (Rated) kW 48.75 50.83 52.78 54.52 55.80
Heating (Max) kW 57.80 60.55 62.62 64.66 66.12
COP Cooling (Rated) 4.08 4.05 3.93 3.92 3.95
Heating (Rated) 4.48 4.41 4.35 4.31 4.32
COP
Heating (Max) 4.20 4.12 4.08 4.03 4.04
SCOP - - - - -
Exterior Color Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray Warm Gray / Dawn Gray
Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus /
Heat Exchanger Type
Black Fin Black Fin Black Fin Black Fin Black Fin
Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed
Type
Scroll Scroll Scroll Scroll Scroll
Combination x No. (Inverter) x 7 (Inverter) x 7 (Inverter) x 7 (Inverter) x 7 (Inverter) x 7
Compressor Motor Output x
W x No. (5,300 x 6) + (4,200 x 1) (5,300 x 6) + (4,200 x 1) (5,300 x 6) + (4,200 x 1) 5,300 x 7 5,300 x 7
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 19,500 19,500 19,500 19,500 19,500
Type Propeller fan Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x
W x No. (900 x 6) + (1,200 x 1) (900 x 6) + (1,200 x 1) (900 x 6) + (1,200 x 1) (900 x 6) + (1,200 x 1) 900 x 8
Number
Fan Air Flow Rate (High) m3/min x No. (320 x 3) + (240 x 1) (320 x 3) + (240 x 1) (320 x 3) + (240 x 1) (320 x 3) + (240 x 1) 320 x 4
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8)
Connections
Low Pressure Gas Pipe mm (inch) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8)
for Heat
Recovery High Pressure Gas Pipe mm (inch) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8)
Pipe Liquid Pipe mm (inch) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8)
Connections
for Heat Pump Gas Pipe mm (inch) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8)
(1,240 x 1,690 x 760) x 3 (1,240 x 1,690 x 760) x 3 (1,240 x 1,690 x 760) x 3 (1,240 x 1,690 x 760) x 3
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 4
+ (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1
(1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3
Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 4
+ (960 x 1,825 x 796) x 1 + (960 x 1,825 x 796) x 1 + (960 x 1,825 x 796) x 1 + (960 x 1,825 x 796) x 1
(310 x 2) + (300 x 1) + (310 x 2) + (300 x 1) + (310 x 2) + (300 x 1) +
Net Weight kg x No. (310 x 3) + (215 x 1) (310 x 3) + (237 x 1)
(215 x 1) (215 x 1) (215 x 1)
(320 x 2) + (312 x 1) + (320 x 2) + (312 x 1) + (320 x 2) + (312 x 1) +
Shipping Weight kg x No. (320 x 3) + (225 x 1) (320 x 3) + (250 x 1)
(225 x 1) (225 x 1) (225 x 1)
Sound Cooling dB(A) 69.2 69.4 70.0 70.1 70.2
Pressure Level Heating dB(A) 71.0 71.4 71.6 72.1 72.1
Sound Cooling dB(A) 99.2 99.4 99.4 99.9 100.1
Power Level Heating dB(A) 103.0 103.2 103.4 103.9 104.1
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A R410A R410A
Precharged Amount
kg 59.5 59.5 59.5 60.5 64.5
in Factory
Refrigerant
t-CO2eq 124.2 124.2 124.2 126.3 134.6
Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion
Control
Valve Valve Valve Valve Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 64 64 64 64 64
1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination (160% ~ 200%). The recommended ratio is 130%.
048 / 049
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION
HP 88 90 92 94 96
Combination Unit ARUM880LTE5 ARUM900LTE5 ARUM920LTE5 ARUM940LTE5 ARUM960LTE5
ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
Model Name ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
Independent Unit
ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
ARUM160LTE5 ARUM180LTE5 ARUM200LTE5 ARUM220LTE5 ARUM240LTE5
Cooling (Rated) kW 246.4 252.0 257.6 263.2 268.8
Btu/h 840,700 859,800 878,900 898,000 917,100
Heating (Rated) kW 246.4 252.0 257.6 263.2 268.8
Capacity
Btu/h 840,700 859,800 878,900 898,000 917,100
Heating (Max) kW 273.2 279.5 285.8 292.1 297.0
Btu/h 932,000 953,500 975,000 996,500 1,013,400
Cooling (Rated) kW 63.13 63.26 64.98 68.15 69.64
Input Heating (Rated) kW 57.95 57.79 59.87 61.82 63.56
Heating (Max) kW 68.79 68.34 71.09 73.16 75.20
COP Cooling (Rated) 3.90 3.98 3.96 3.86 3.86
SEER - - - - -
Heating (Rated) 4.25 4.36 4.30 4.26 4.23
COP
Heating (Max) 3.97 4.09 4.02 3.99 3.95
SCOP - - - - -
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL Code (Classic) NL503K / NA507K NL503K / NA507K NL503K / NA507K NL503K / NA507K NL503K / NA507K
Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus / Wide Louver Plus /
Heat Exchanger Type
Black Fin Black Fin Black Fin Black Fin Black Fin
Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed Hermetically Sealed
Type
Scroll Scroll Scroll Scroll Scroll
Combination x No. (Inverter) x 7 (Inverter) x 8 (Inverter) x 8 (Inverter) x 8 (Inverter) x 8
Compressor Motor Output x
W x No. 5,300 x 7 (5,300 x 7) + (4,200 x 1) (5,300 x 7) + (4,200 x 1) (5,300 x 7) + (4,200 x 1) 5,300 x 8
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 19,500 20,800 20,800 20,800 20,800
Type Propeller fan Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x
W x No. 900 x 8 900 x 8 900 x 8 900 x 8 900 x 8
Number
Fan Air Flow Rate (High) m /min x No.
3
320 x 4 320 x 4 320 x 4 320 x 4 320 x 4
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8)
Connections
Low Pressure Gas Pipe mm (inch) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8)
for Heat
Recovery High Pressure Gas Pipe mm (inch) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8)
Pipe Liquid Pipe mm (inch) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8)
Connections
for Heat Pump Gas Pipe mm (inch) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8)
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 4 (1,240 x1,690 x 760) x 4 (1,240 x1,690 x 760) x 4 (1,240 x1,690 x 760) x 4 (1,240 x1,690 x 760) x 4
Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 4 (1,280 x 1,825 x 796) x 4 (1,280 x 1,825 x 796) x 4 (1,280 x 1,825 x 796) x 4 (1,280 x 1,825 x 796) x 4
Net Weight kg x No. (310 x 3) + (237 x 1) (310 x 3) + (300 x 1) (310 x 3) + (300 x 1) (310 x 3) + (300 x 1) 310 x 4
Shipping Weight kg x No. (320 x 3) + (250 x 1) (320 x 3) + (312 x 1) (320 x 3) + (312 x 1) (320 x 3) + (312 x 1) 320 x 4
Sound Cooling dB(A) 70.3 70.3 70.4 70.9 71.0
Pressure Level Heating dB(A) 72.2 72.2 72.5 72.7 73.0
Sound Cooling dB(A) 100.2 100.4 100.6 100.6 101.0
Power Level Heating dB(A) 104.2 104.3 104.4 104.6 105.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A R410A R410A
Precharged Amount
kg 64.5 67.0 67.0 67.0 68.0
in Factory
Refrigerant
t-CO2eq 134.6 139.9 139.9 139.9 142.0
Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion Electronic Expansion
Control
Valve Valve Valve Valve Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 64 64 64 64 64
1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination (160% ~ 200%). The recommended ratio is 130%.
OUTDOOR UNIT _ MULTI V 5 _ NOTE
NOTE
1. Eurovent Test Condition : For more info regarding program consult www.eurovent-certification.com
3. Wiring cable size must comply with the applicable local and national code.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Explanation of Terms
• EER : Energy Efficiency Ratio (Cooling)
• COP : Coefficient Of Performance (Heating)
• SCOP : Seasonal Coefficient Of Performance (Refer to Typical Heating Season)
6. Due to our policy of innovation some specifications may be changed without notification.
050 / 051
OUTDOOR UNITS _ MULTI V 5 _ TECHNICAL DATA
234#"5"678!(9(234#:""678!(9(234#:*"678!
/!0&*)$
7 Wire routing hole (Front) 2-Ø30
!!!!,'-.*$/!0&*)$
*+(,'-./0'1/0
#$%&'()(!!
!!!!,'-.*$/!0&*)$
-.*$/!0&*)$
!!!!,'-.*$/!0&*)$
3D View
1,690
;33<*)6=>?
799
144 159 71 71
462
625 414
670
675 760
735
740
930
"#$%&&'!()*$+
731
101 730
234-!!6789+#:#234-!56789+#:#234-!;6789+
234-,56789+#:#234-,;6789+#:#234-,<6789+#:#234-!66789+
!"#$%&'()%*()
-./0%#1#+!
3D View
;//<*)3=>?
1,690
280
FDCNBH!ALIEE!<LKE
FB H!AOIGL!<
FB F
267
214 NDCBGH!AOIGL!<NKB
FDCNB H!AOIGL!<
FD
FDCNB
205 BFCDGH!AOIGL!<NKB
NDCBG H!AOIGL!<
ND
NDCBG
154
DFCDBH!AOIGL!<NKB
BFCDG H!FFIF!<J
BF
BFCDG
125
DDCODH!FFIF!<JKE>
DFCDB H!FFIF!<J
DF
DFCDB
109
92
DDCOD H!FFIF!<JKE>
DD
DDCOD
189
76
100 1,040
052 / 053
HEAT PUMP
- Air Cooled VRF Heat Pump
- 22.4kW ~ 268.8kW (Cooling capacity based)
- 3Ø, 380 ~ 415V, 50Hz
- Top discharge outdoor unit
Designed
Design
For
For
The Ultimate
The Ultimate
1,000m 225m
TOTAL PIPING LENGTH Longest Piping Length
Piping capabilities
110m
Actual longest piping length (Equivalent) !"":)P!!E:R
@-065/')=&=&06)4506'()+H'5,)#/')I,+07()P7-01&'&-0+4)+==4&7+'&-0R 40m (90m)
Height between ODU ~ IDU ##":
Height between IDU ~ IDU 40m
Height between ODU ~ ODU E:
Energy savings
Partial Defrost
Reliability
Low noise
Advanced performance
054 / 055
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION
HP 8 10 12 14
Combination Unit ARUN080LTE5 ARUN100LTE5 ARUN120LTE5 ARUN140LTE5
Model Name
Independent Unit ARUN080LTE5 ARUN100LTE5 ARUN120LTE5 ARUN140LTE5
kW 22.4 28.0 33.6 39.2
Cooling (Rated) Btu/h*1 76,400 95,500 114,600 133,800
Capacity Btu/h*2 78,300 96,200 115,300 134,400
kW 25.2 31.5 37.8 44.1
Heating (Rated)
Btu/h 86,000 107,500 129,000 150,500
Cooling (Rated) kW 4.59 5.70 7.91 9.12
Input
Heating (Rated) kW 4.74 5.78 8.06 9.78
COP Cooling (Rated) 4.88 4.91 4.25 4.30
COP Heating (Rated) 5.32 5.45 4.69 4.51
Power Factor Rated - 0.93 0.93 0.93 0.93
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL code RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037
Heat Exchanger Wide Louver Plus Wide Louver Plus Wide Louver Plus Wide Louver Plus
Compressor Motor Output x Number W x No. 5,300 x 1 5,300 x 1 5,300 x 1 5,300 x 1
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W 1,200 x 1 1,200 x 1 1,200 x 1 900 x 2
m3/min 240 x 1 240 x 1 240 x 1 320 x 1
Air Flow Rate (High)
Fan ft3/min 8,476 x 1 8,476 x 1 8,476 x 1 11,301 x 1
External Static Pressure (Max, Pa) 80 80 80 80
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) 9.52 (3/8) 9.52 (3/8) 12.7 (1/2) 12.7 (1/2)
Connections Gas Pipe mm (inch) 19.05 (3/4) 22.2 (7/8) 28.58 (1-1/8) 28.58 (1-1/8)
Dimensions (W x H x D) mm x No. (930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1
Net Weight kg 199 x 1 199 x 1 199 x 1 221 x 1
Sound Cooling dB(A) 58.0 58.0 59.0 60.0
Pressure Level Heating dB(A) 59.0 59.0 60.0 61.0
Sound Cooling dB(A) 78.0 78.0 79.0 82.0
Power Level Heating dB(A) 79.0 79.0 80.0 84.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A R410A R410A
Precharged Amount kg 10.0 10.0 10.0 13.0
Refrigerant in factory lbs 22.0 22.0 22.0 28.7
t-CO2eq 20.9 20.9 20.9 27.1
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Number of maximum connectable indoor units 13 (20) 16 (25) 20 (30) 23 (35)
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design.
Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*1 Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
*2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination.
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
MULTI V 5 HEAT PUMP
ARUN160LTE5 / ARUN180LTE5
ARUN200LTE5 / ARUN220LTE5
HP 16 18 20 22
Combination Unit ARUN160LTE5 ARUN180LTE5 ARUN200LTE5 ARUN220LTE5
Model Name
Independent Unit ARUN160LTE5 ARUN180LTE5 ARUN200LTE5 ARUN220LTE5
kW 44.8 50.4 56.0 61.6
Cooling (Rated) Btu/h*1 152,900 172,000 191,100 210,200
Capacity Btu/h*2 153,900 173,000 192,400 211,500
kW 50.4 56.7 63.0 69.3
Heating (Rated)
Btu/h 172,000 193,500 215,000 236,500
Cooling (Rated) kW 10.80 10.96 12.31 14.84
Input
Heating (Rated) kW 11.59 12.06 15.52 17.54
COP Cooling (Rated) 4.15 4.60 4.55 4.15
COP Heating (Rated) 4.35 4.70 4.06 3.95
Power Factor Rated - 0.93 0.93 0.93 0.93
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL code RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037
Heat Exchanger Wide Louver Plus Wide Louver Plus Wide Louver Plus Wide Louver Plus
Compressor Motor Output x Number W x No. 5,300 x 1 5,300 x 1 + 4,200 x 1 5,300 x 2 5,300 x 2
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W 900 x 2 900 x 2 900 x 2 900 x 2
m3/min 320 x 1 320 x 1 320 x 1 320 x 1
Air Flow Rate (High)
Fan ft3/min 11,301 x 1 11,301 x 1 11,301 x 1 11,301 x 1
External Static Pressure (Max, Pa) 80 80 80 80
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) 12.7 (1/2) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8)
Connections Gas Pipe mm (inch) 28.58 (1-1/8) 28.58 (1-1/8) 28.58 (1-1/8) 28.58 (1-1/8)
Dimensions (W x H x D) mm x No. (1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1
Net Weight kg 221 x 1 261 x 1 281 x 1 281 x 1
Sound Cooling dB(A) 60.5 61.0 62.0 64.5
Pressure Level Heating dB(A) 61.5 62.0 64.5 65.5
Sound Cooling dB(A) 83.0 85.0 86.0 86.0
Power Level Heating dB(A) 85.0 86.0 87.0 88.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A R410A R410A
Precharged Amount kg 13.0 13.0 14.0 14.0
Refrigerant in factory lbs 28.7 28.7 30.9 30.9
t-CO2eq 27.1 27.1 29.2 29.2
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Number of maximum connectable indoor units 26 (40) 29 (45) 32 (50) 35 (56)
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design.
Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*1 Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
*2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination.
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
056 / 057
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION
HP 24 26
Combination Unit ARUN240LTE5 ARUN260LTE5
Model Name
Independent Unit ARUN240LTE5 ARUN260LTE5
kW 67.2 72.8
Cooling (Rated)
Btu/h*1 229,300 248,400
Capacity Btu/h*2 230,700 249,800
kW 74.3 74.3
Heating (Rated)
Btu/h 253,400 253,400
Cooling (Rated) kW 16.76 19.41
Input
Heating (Rated) kW 18.85 19.49
COP Cooling (Rated) 4.01 3.75
COP Heating (Rated) 3.94 3.81
Power Factor Rated - 0.93 0.93
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL code RAL 7030 / RAL 7037 RAL 7030 / RAL 7037
Heat Exchanger Wide Louver Plus Wide Louver Plus
Compressor Motor Output x Number W x No. 5,300 x 2 5,300 x 2
Type Propeller fan Propeller fan
Motor Output x Number W 900 x 2 900 x 2
m3/min 320 x 1 320 x 1
Air Flow Rate (High)
Fan ft3/min 11,301 x 1 11,301 x 1
External Static Pressure (Max, Pa) 80 80
Drive DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP
Pipe Liquid Pipe mm (inch) 15.88 (5/8) 19.05 (3/4)
Connections Gas Pipe mm (inch) 34.9 (1-3/8) 34.9 (1-3/8)
Dimensions (W x H x D) mm x No. (1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1
Net Weight kg 283 x 1 283 x 1
Sound Cooling dB(A) 65.0 65.0
Pressure Level Heating dB(A) 67.0 67.0
Sound Cooling dB(A) 88.0 88.0
Power Level Heating dB(A) 90.0 90.0
mm2 x No.
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A
Precharged Amount kg 16.0 16.0
Refrigerant in factory lbs 35.3 35.3
t-CO2eq 33.4 33.4
Control Electronic Expansion Valve Electronic Expansion Valve
3, 380-415, 50 3, 380-415, 50
Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60
Number of maximum connectable indoor units 39 (61) 42 (64)
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design.
Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*1 Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
*2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination.
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
MULTI V 5 HEAT PUMP
ARUN280LTE5 / ARUN300LTE5
ARUN320LTE5
HP 28 30 32
Combination Unit ARUN280LTE5 ARUN300LTE5 ARUN320LTE5
Model Name ARUN160LTE5 ARUN180LTE5 ARUN200LTE5
Independent Unit
ARUN120LTE5 ARUN120LTE5 ARUN120LTE5
kW 78.4 84.0 89.6
Cooling (Rated) Btu/h*1 267,500 286,600 305,700
Capacity Btu/h*2 269,200 288,300 307,800
kW 88.2 94.5 100.8
Heating (Rated)
Btu/h 301,000 322,500 344,000
Cooling (Rated) kW 18.70 18.86 20.21
Input
Heating (Rated) kW 19.65 20.12 23.58
COP Cooling (Rated) 4.19 4.45 4.43
COP Heating (Rated) 4.49 4.70 4.28
Power Factor Rated - 0.93 0.93 0.93
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL code RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037
Heat Exchanger Wide Louver Plus Wide Louver Plus Wide Louver Plus
Compressor Motor Output x Number W x No. 5,300 x 2 (5,300 x 2) + (4,200 x 1) (5,300 x 2) + (4,200 x 1)
Type Propeller fan Propeller fan Propeller fan
Motor Output x Number W (900 x 2) + (1,200 x 1) (900 x 2) + (1,200 x 1) (900 x 2) + (1,200 x 1)
m3/min (320 x 1) + (240 x 1) (320 x 1) + (240 x 1) (320 x 1) + (240 x 1)
Air Flow Rate (High)
Fan ft3/min (11,301 x 1) + (8,476 x 1) (11,301 x 1) + (8,476 x 1) (11,301 x 1) + (8,476 x 1)
External Static Pressure (Max, Pa) 80 80 80
Drive DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP
Pipe Liquid Pipe mm (inch) 19.05 (3/4) 19.05 (3/4) 19.05 (3/4)
Connections Gas Pipe mm (inch) 34.9 (1-3/8) 34.9 (1-3/8) 34.9 (1-3/8)
(1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1
Dimensions (W x H x D) mm x No.
+ (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1
Net Weight kg (221 x 1) + (199 x 1) (261 x 1) + (199 x 1) (281 x 1) + (199 x 1)
Sound Cooling dB(A) 62.8 63.1 63.8
Pressure Level Heating dB(A) 63.8 64.1 65.8
Sound Cooling dB(A) 84.5 86.0 86.8
Power Level Heating dB(A) 86.2 87.0 87.8
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A R410A
Precharged Amount kg 13.0 + 10.0 13.0 + 10.0 14.0 + 10.0
Refrigerant in factory lbs 28.7 + 22.0 28.7 + 22.0 30.9 + 22.0
t-CO2eq 48.0 48.0 50.1
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60
Number of maximum connectable indoor units 45 (56) 49 (60) 52 (64)
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design.
Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*1 Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
*2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination.
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
058 / 059
MULTI V 5 HEAT PUMP
ARUN300LTN5 / ARUN320LTN5
HP 30' 32'
Combination Unit ARUN300LTN5 ARUN320LTN5
Model Name
Independent Unit ARUN300LTN5 ARUN320LTN5
kW 84.0 89.6
Cooling (Rated)
Btu/h*1 286,600 305,700
Capacity Btu/h*2 288,300 307,800
kW 94.5 100.8
Heating (Rated)
Btu/h 322,400 343,900
Cooling (Rated) kW 22.40 27.15
Input
Heating (Rated) kW 22.00 24.90
COP Cooling (Rated) 3.75 3.30
COP Heating (Rated) 4.30 4.05
Power Factor Rated - 0.93 0.93
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL code RAL 7030 / RAL 7037 RAL 7030 / RAL 7037
Heat Exchanger Wide Louver Plus Wide Louver Plus
Compressor Motor Output x Number W x No. 5,300 x 2 5,300 x 2
Type Propeller Fan Propeller Fan
Motor Output x Number W 1,500 x 2 1,500 x 2
m3/min 430 x 2 430 x 2
Air Flow Rate (High)
Fan ft3/min 15,185 x 2 15,185 x 2
External Static Pressure (Max, Pa) 80 80
Drive DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP
Pipe Liquid Pipe mm (inch) 19.05 (3/4) 19.05 (3/4)
Connections Gas Pipe mm (inch) 34.9 (1-3/8) 34.9 (1-3/8)
Dimensions (W x H x D) mm x No. (1,640 x 1,690 x 760) x 1 (1,640 x 1,690 x 760) x 1
Net Weight kg 362 x 1 362 x 1
Sound Cooling dB(A) 65.0 65.0
Pressure Level Heating dB(A) 67.0 67.0
Sound Cooling dB(A) 88.0 88.0
Power Level Heating dB(A) 90.0 90.0
mm2 x No.
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A
Precharged Amount kg 17.5 17.5
Refrigerant in factory lbs 38.6 38.6
t-CO2eq 36.5 36.5
Control Electronic Expansion Valve Electronic Expansion Valve
3, 380-415, 50 3, 380-415, 50
Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60
Number of maximum connectable indoor units 49 (60) 52 (64)
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design.
Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*1 Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
*2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination.
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
MULTI V 5 HEAT PUMP
ARUN340LTE5 / ARUN360LTE5
ARUN380LTE5 / ARUN400LTE5
HP 34 36 38 40
Combination Unit ARUN340LTE5 ARUN360LTE5 ARUN380LTE5 ARUN400LTE5
Model Name ARUN220LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
Independent Unit
ARUN120LTE5 ARUN120LTE5 ARUN140LTE5 ARUN160LTE5
kW 95.2 100.8 106.4 112.0
Cooling (Rated) Btu/h*1 324,800 343,900 363,100 382,200
Capacity Btu/h*2 326,900 346,300 356,400 384,900
kW 107.1 112.1 118.4 124.7
Heating (Rated)
Btu/h 365,500 382,400 403,900 425,400
Cooling (Rated) kW 22.75 24.66 25.87 27.55
Input
Heating (Rated) kW 25.60 26.91 28.62 30.43
COP Cooling (Rated) 4.18 4.09 4.11 4.06
COP Heating (Rated) 4.18 4.16 4.13 4.10
Power Factor Rated - 0.93 0.93 0.93 0.93
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL code RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037
Heat Exchanger Wide Louver Plus Wide Louver Plus Wide Louver Plus Wide Louver Plus
Compressor Motor Output x Number W x No. 5,300 x 3 5,300 x 3 5,300 x 3 5,300 x 3
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W (900 x 2) + (1,200 x 1) (900 x 2) + (1,200 x 1) 900 x 4 900 x 4
m3/min (320 x 1) + (240 x 1) (320 x 1) + (240 x 1) 320 x 2 320 x 2
Air Flow Rate (High)
Fan ft3/min (11,301 x 1) + (8,476 x 1) (11,301 x 1) + (8,476 x 1) 11,301 x 2 11,301 x 2
External Static Pressure (Max, Pa) 80 80 80 80
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) 19.05 (3/4) 19.05 (3/4) 19.05 (3/4) 19.05 (3/4)
Connections Gas Pipe mm (inch) 34.9 (1-3/8) 41.3 (1-5/8) 41.3 (1-5/8) 41.3 (1-5/8)
(1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 2 (1,240 x1,690 x 760) x 2
+ (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1
Net Weight kg (281 x 1) + (199 x 1) (283 x 1) + (199 x 1) (283 x 1) + (221 x 1) (283 x 1) + (221 x 1)
Sound Cooling dB(A) 65.6 66.0 66.2 66.3
Pressure Level Heating dB(A) 66.6 67.8 68.0 68.1
Sound Cooling dB(A) 86.8 88.5 89.0 89.2
Power Level Heating dB(A) 88.6 90.4 91.0 91.2
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A R410A R410A
Precharged Amount kg 14.0 + 10.0 16.0 + 10.0 16.0 + 13.0 16.0 + 13.0
Refrigerant in factory lbs 30.9 + 22.0 35.3 + 22.0 35.3 + 28.7 35.3 + 28.7
t-CO2eq 50.1 54.3 60.5 60.5
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Number of maximum connectable indoor units 55 (64) 58 (64) 61 (64) 64
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design.
Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*1 Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
*2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination.
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
060 / 061
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION
HP 42 44 46 48
Combination Unit ARUN420LTE5 ARUN440LTE5 ARUN460LTE5 ARUN480LTE5
Model Name ARUN240LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
Independent Unit
ARUN180LTE5 ARUN200LTE5 ARUN220LTE5 ARUN240LTE5
kW 117.6 123.2 128.8 134.4
Cooling (Rated) Btu/h 401,300 420,400 439,500 458,600
Capacity Btu/h 403,600 423,100 442,500 461,600
kW 131.0 137.3 143.6 148.5
Heating (Rated)
Btu/h 446,900 468,400 489,900 506,800
Cooling (Rated) kW 27.71 29.07 31.60 33.52
Input
Heating (Rated) kW 30.91 34.36 36.39 37.69
COP Cooling (Rated) 4.24 4.24 4.08 4.01
COP Heating (Rated) 4.24 3.99 3.94 3.94
Power Factor Rated - 0.93 0.93 0.93 0.93
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL code RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037
Heat Exchanger Wide Louver Plus Wide Louver Plus Wide Louver Plus Wide Louver Plus
Compressor Motor Output x Number W x No. (5,300 x 3) + (4,200 x 1) 5,300 x 4 5,300 x 4 5,300 x 4
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W 900 x 4 900 x 4 900 x 4 900 x 4
m3/min 320 x 2 320 x 2 320 x 2 320 x 2
Air Flow Rate (High)
Fan ft3/min 11,301 x 2 11,301 x 2 11,301 x 2 11,301 x 2
External Static Pressure (Max, Pa) 80 80 80 80
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) 19.05 (3/4) 19.05 (3/4) 19.05 (3/4) 19.05 (3/4)
Connections Gas Pipe mm (inch) 41.3 (1-5/8) 41.3 (1-5/8) 41.3 (1-5/8) 41.3 (1-5/8)
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 2 (1,240 x1,690 x 760) x 2 (1,240 x1,690 x 760) x 2 (1,240 x1,690 x 760) x 2
Net Weight kg (283 x 1) + (261 x 1) (283 x 1) + (281 x 1) (283 x 1) + (281 x 1) 283 x 2
Sound Cooling dB(A) 66.5 66.8 67.8 68.0
Pressure Level Heating dB(A) 68.2 68.9 69.3 70.0
Sound Cooling dB(A) 89.8 90.1 90.1 91.0
Power Level Heating dB(A) 91.5 91.8 92.1 93.0
mm2 x No.
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A R410A R410A
Precharged Amount kg 16.0 + 13.0 16.0 + 14.0 16.0 + 14.0 16.0 + 16.0
Refrigerant in factory lbs 35.3 + 28.7 35.3 + 30.9 35.3 + 30.9 35.3 + 35.3
t-CO2eq 60.5 62.6 62.6 66.8
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Number of maximum connectable indoor units 64 64 64 64
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design.
Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*1 Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
*2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination.
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
MULTI V 5 HEAT PUMP
ARUN500LTE5 / ARUN520LTE5
ARUN540LTE5 / ARUN560LTE5
HP 50 52 54 56
Combination Unit ARUN500LTE5 ARUN520LTE5 ARUN540LTE5 ARUN560LTE5
Model Name ARUN240LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
Independent Unit ARUN140LTE5 ARUN160LTE5 ARUN180LTE5 ARUN200LTE5
ARUN120LTE5 ARUN120LTE5 ARUN120LTE5 ARUN120LTE5
kW 140.0 145.6 151.2 156.8
Cooling (Rated) Btu/h*1 477,700 496,800 515,900 535,000
Capacity Btu/h*2 481,100 500,200 519,300 538,800
kW 156.2 162.5 168.8 175.1
Heating (Rated)
Btu/h 532,900 554,400 575,900 597,400
Cooling (Rated) kW 33.78 35.46 35.62 36.97
Input
Heating (Rated) kW 36.68 38.49 38.97 42.42
COP Cooling (Rated) 4.14 4.11 4.24 4.24
COP Heating (Rated) 4.26 4.22 4.33 4.13
Power Factor Rated - 0.93 0.93 0.93 0.93
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL code RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037
Heat Exchanger Wide Louver Plus Wide Louver Plus Wide Louver Plus Wide Louver Plus
Compressor Motor Output x Number W x No. 5,300 x 4 5,300 x 4 (5,300 x 4) + (4,200 x 1) 5,300 x 5
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W (900 x 4) + (1,200 x 1) (900 x 4) + (1,200 x 1) (900 x 4) + (1,200 x 1) (900 x 4) + (1,200 x 1)
m3/min (320 x 2) + (240 x 1) (320 x 2) + (240 x 1) (320 x 2) + (240 x 1) (320 x 2) + (240 x 1)
Air Flow Rate (High)
Fan ft3/min (11,301 x 2) + (8,476 x 1) (11,301 x 2) + (8,476 x 1) (11,301 x 2) + (8,476 x 1) (11,301 x 2) + (8,476 x 1)
External Static Pressure (Max, Pa) 80 80 80 80
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) 19.05 (3/4) 19.05 (3/4) 19.05 (3/4) 19.05 (3/4)
Connections Gas Pipe mm (inch) 41.3 (1-5/8) 41.3 (1-5/8) 41.3 (1-5/8) 41.3 (1-5/8)
(1,240 x 1,690 x 760) x 2 (1,240 x 1,690 x 760) x 2 (1,240 x 1,690 x 760) x 2 (1,240 x 1,690 x 760) x 2
Dimensions (W x H x D) mm x No.
+ (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1
(283 x 1) + (221 x 1) + (283 x 1) + (221 x 1) + (283 x 1) + (261 x 1) + (283 x 1) + (281 x 1) +
Net Weight kg
(199 x 1) (199 x 1) (199 x 1) (199 x 1)
Sound Cooling dB(A) 67.0 67.1 67.2 67.4
Pressure Level Heating dB(A) 68.6 68.7 68.8 69.5
Sound Cooling dB(A) 89.4 89.6 90.1 90.4
Power Level Heating dB(A) 91.3 91.5 91.8 92.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A R410A R410A
Precharged Amount kg 16.0 + 13.0 + 10.0 16.0 + 13.0 + 10.0 16.0 + 13.0 + 10.0 16.0 + 14.0 + 10.0
Refrigerant in factory lbs 35.3 + 28.7 + 22.0 35.3 + 28.7 + 22.0 35.3 + 28.7 + 22.0 35.3 + 30.9 + 22.0
t-CO2eq 81.4 81.4 81.4 83.5
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Number of maximum connectable indoor units 64 64 64 64
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design.
Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*1 Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
*2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination.
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
062 / 063
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION
HP 58 60 62 64
Combination Unit ARUN580LTE5 ARUN600LTE5 ARUN620LTE5 ARUN640LTE5
Model Name ARUN240LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
Independent Unit ARUN220LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
ARUN120LTE5 ARUN120LTE5 ARUN140LTE5 ARUN160LTE5
kW 162.4 168.0 173.6 179.2
Cooling (Rated) Btu/h*1 554,100 573,200 592,400 611,500
Capacity Btu/h*2 557,900 577,300 595,700 614,800
kW 181.4 186.3 192.6 198.9
Heating (Rated)
Btu/h 618,900 635,800 657,300 678,800
Cooling (Rated) kW 39.51 41.42 42.63 44.31
Input
Heating (Rated) kW 44.45 45.75 47.47 49.28
COP Cooling (Rated) 4.11 4.06 4.07 4.04
COP Heating (Rated) 4.08 4.07 4.06 4.04
Power Factor Rated - 0.93 0.93 0.93 0.93
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL code RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037
Heat Exchanger Wide Louver Plus Wide Louver Plus Wide Louver Plus Wide Louver Plus
Compressor Motor Output x Number W x No. 5,300 x 5 5,300 x 5 5,300 x 5 5,300 x 5
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W (900 x 4) + (1,200 x 1) (900 x 4) + (1,200 x 1) 900 x 6 900 x 6
m3/min (320 x 2) + (240 x 1) (320 x 2) + (240 x 1) 320 x 3 320 x 3
Air Flow Rate (High)
Fan ft3/min (11,301 x 2) + (8,476 x 1) (11,301 x 2) + (8,476 x 1) 11,301 x 3 11,301 x 3
External Static Pressure (Max, Pa) 80 80 80 80
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) 19.05 (3/4) 19.05 (3/4) 22.2 (7/8) 22.2 (7/8)
Connections Gas Pipe mm (inch) 41.3 (1-5/8) 41.3 (1-5/8) 41.3 (1-5/8) 41.3 (1-5/8)
(1,240 x 1,690 x 760) x 2 (1,240 x 1,690 x 760) x 2
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 3 (1,240 x1,690 x 760) x 3
+ (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1
(283 x 1) + (281 x 1) +
Net Weight kg (283 x 2) + (199 x 1) (283 x 2) + (221 x 1) (283 x 2) + (221 x 1)
(199 x 1)
Sound Cooling dB(A) 68.3 68.5 68.6 68.7
Pressure Level Heating dB(A) 69.8 70.4 70.5 70.6
Sound Cooling dB(A) 90.4 91.3 91.5 91.6
Power Level Heating dB(A) 92.4 93.2 93.5 93.6
No. x mm2.
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A R410A R410A
Precharged Amount kg 16.0 + 14.0 + 10.0 16.0 + 16.0 + 10.0 16.0 + 16.0 + 13.0 16.0 + 16.0 + 13.0
Refrigerant in factory lbs 35.3 + 30.9 + 22.0 35.3 + 35.3 + 22.0 35.3 + 35.3 + 28.7 35.3 + 35.3 + 28.7
t-CO2eq 83.5 87.7 93.9 93.9
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Number of maximum connectable indoor units 64 64 64 64
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design.
Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*1 Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
*2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination.
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
MULTI V 5 HEAT PUMP
ARUN660LTE5 / ARUN680LTE5
ARUN700LTE5 / ARUN720LTE5
HP 66 68 70 72
Combination Unit ARUN660LTE5 ARUN680LTE5 ARUN700LTE5 ARUN720LTE5
Model Name ARUN240LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
Independent Unit ARUN240LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
ARUN180LTE5 ARUN200LTE5 ARUN220LTE5 ARUN240LTE5
kW 184.8 190.4 196.0 201.6
Cooling (Rated) Btu/h*1 630,600 649,700 668,800 687,900
Capacity Btu/h*2 634,300 653,700 673,200 692,300
kW 205.2 211.5 217.8 222.8
Heating (Rated)
Btu/h 700,300 721,800 743,300 760,200
Cooling (Rated) kW 44.47 45.82 48.36 50.27
Input
Heating (Rated) kW 49.76 53.21 55.24 56.54
COP Cooling (Rated) 4.16 4.16 4.05 4.01
COP Heating (Rated) 4.12 3.97 3.94 3.94
Power Factor Rated - 0.93 0.93 0.93 0.93
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL code RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037
Heat Exchanger Wide Louver Plus Wide Louver Plus Wide Louver Plus Wide Louver Plus
Compressor Motor Output x Number W x No. (5,300 x 5) + (4,200 x 1) 5,300 x 6 5,300 x 6 5,300 x 6
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W 900 x 6 900 x 6 900 x 6 900 x 6
m3/min 320 x 3 320 x 3 320 x 3 320 x 3
Air Flow Rate (High)
Fan ft3/min 11,301 x 3 11,301 x 3 11,301 x 3 11,301 x 3
External Static Pressure (Max, Pa) 80 80 80 80
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) 22.2 (7/8) 22.2 (7/8) 22.2 (7/8) 22.2 (7/8)
Connections Gas Pipe mm (inch) 53.98 (2-1/8) 53.98 (2-1/8) 53.98 (2-1/8) 53.98 (2-1/8)
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 3 (1,240 x1,690 x 760) x 3 (1,240 x1,690 x 760) x 3 (1,240 x1,690 x 760) x 3
Net Weight kg (283 x 2) + (261 x 1) (283 x 2) + (281 x 1) (283 x 2) + (281 x 1) 283 x 3
Sound Cooling dB(A) 68.8 69.0 69.6 69.8
Pressure Level Heating dB(A) 70.6 71.1 71.3 71.8
Sound Cooling dB(A) 92.0 92.2 92.2 92.8
Power Level Heating dB(A) 93.8 94.0 94.2 94.8
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A R410A R410A
Precharged Amount kg 16.0 + 16.0 + 13.0 16.0 + 16.0 + 14.0 16.0 + 16.0 + 14.0 16.0 + 16.0 + 16.0
Refrigerant in factory lbs 35.3 + 35.3 + 28.7 35.3 + 35.3 + 30.9 35.3 + 35.3 + 30.9 35.3 + 35.3 + 35.3
t-CO2eq 93.9 96.0 96.0 100.2
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Number of maximum connectable indoor units 64 64 64 64
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design.
Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*1 Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
*2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination.
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
064 / 065
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION
HP 74 76 78 80
Combination Unit ARUN740LTE5 ARUN760LTE5 ARUN780LTE5 ARUN800LTE5
ARUN240LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
Model Name ARUN240LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
Independent Unit
ARUN140LTE5 ARUN160LTE5 ARUN180LTE5 ARUN200LTE5
ARUN120LTE5 ARUN120LTE5 ARUN120LTE5 ARUN120LTE5
kW 207.2 212.8 218.4 224.0
Cooling (Rated) Btu/h*1 707,000 726,100 745,200 764,300
Capacity Btu/h*2 711,700 730,900 759,300 769,700
kW 230.4 236.7 243.0 249.3
Heating (Rated)
Btu/h 786,300 807,800 829,300 850,800
Cooling (Rated) kW 50.54 52.22 52.38 53.73
Input
Heating (Rated) kW 55.53 57.34 57.82 61.27
COP Cooling (Rated) 4.10 4.08 4.17 4.17
COP Heating (Rated) 4.15 4.13 4.20 4.07
Power Factor Rated - 0.93 0.93 0.93 0.93
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL code RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037
Heat Exchanger Wide Louver Plus Wide Louver Plus Wide Louver Plus Wide Louver Plus
Compressor Motor Output x Number W x No. 5,300 x 6 5,300 x 6 (5,300 x 6) + (4,200 x 1) 5,300 x 7
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W (900 x 6) + (1,200 x 1) (900 x 6) + (1,200 x 1) (900 x 6) + (1,200 x 1) (900 x 6) + (1,200 x 1)
m3/min (320 x 3) + (240 x 1) (320 x 3) + (240 x 1) (320 x 3) + (240 x 1) (320 x 3) + (240 x 1)
Air Flow Rate (High)
Fan ft3/min (11,301 x 3) + (8,476 x 1) (11,301 x 3) + (8,476 x 1) (11,301 x 3) + (8,476 x 1) (11,301 x 3) + (8,476 x 1)
External Static Pressure (Max, Pa) 80 80 80 80
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) 22.2 (7/8) 22.2 (7/8) 22.2 (7/8) 22.2 (7/8)
Connections Gas Pipe mm (inch) 53.98 (2-1/8) 53.98 (2-1/8) 53.98 (2-1/8) 53.98 (2-1/8)
(1,240 x 1,690 x 760) x 3 (1,240 x 1,690 x 760) x 3 (1,240 x 1,690 x 760) x 3 (1,240 x 1,690 x 760) x 3
Dimensions (W x H x D) mm x No.
+ (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1
Net Weight kg (283 x 2) + (221 x 1) + (199 x 1) (283 x 2) + (221 x 1) + (199 x 1) (283 x 2) + (261 x 1) + (199 x 1) (283 x 2) + (281 x 1) + (199 x 1)
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design.
Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*1 Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
*2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination.
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
MULTI V 5 HEAT PUMP
ARUN820LTE5 / ARUN840LTE5
ARUN860LTE5 / ARUN880LTE5
HP 82 84 86 88
Combination Unit ARUN820LTE5 ARUN840LTE5 ARUN860LTE5 ARUN880LTE5
ARUN240LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
Model Name ARUN240LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
Independent Unit
ARUN220LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
ARUN120LTE5 ARUN120LTE5 ARUN140LTE5 ARUN160LTE5
kW 229.6 235.2 240.8 246.4
Cooling (Rated) Btu/h*1 783,400 802,500 821,700 840,800
Capacity Btu/h*2 788,200 807,400 826,500 846,800
kW 255.6 260.6 266.9 273.2
Heating (Rated)
Btu/h 872,300 889,200 910,700 932,200
Cooling (Rated) kW 56.27 58.18 59.39 61.07
Input
Heating (Rated) kW 63.30 64.60 66.32 68.13
COP Cooling (Rated) 4.08 4.04 4.05 4.03
COP Heating (Rated) 4.04 4.03 4.02 4.01
Power Factor Rated - 0.93 0.93 0.93 0.93
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL code RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037
Heat Exchanger Wide Louver Plus Wide Louver Plus Wide Louver Plus Wide Louver Plus
Compressor Motor Output x Number W x No. 5,300 x 7 5,300 x 7 5,300 x 7 5,300 x 7
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W (900 x 6) + (1,200 x 1) (900 x 6) + (1,200 x 1) 900 x 8 900 x 8
m3/min (320 x 3) + (240 x 1) (320 x 3) + (240 x 1) 320 x 4 320 x 4
Air Flow Rate (High)
Fan ft3/min (11,301 x 3) + (8,476 x 1) (11,301 x 3) + (8,476 x 1) 11,301 x 4 11,301 x 4
External Static Pressure (Max, Pa) 80 80 80 80
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) 22.2 (7/8) 22.2 (7/8) 22.2 (7/8) 22.2 (7/8)
Connections Gas Pipe mm (inch) 53.98 (2-1/8) 53.98 (2-1/8) 53.98 (2-1/8) 53.98 (2-1/8)
(1,240 x 1,690 x 760) x 3 (1,240 x 1,690 x 760) x 3
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 4 (1,240 x1,690 x 760) x 4
+ (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1
Net Weight kg (283 x 2) + (281 x 1) + (199 x 1) (283 x 3) + (199 x 1) (283 x 3) + (221 x 1) (283 x 3) + (221 x 1)
Sound Cooling dB(A) 70.0 70.1 70.2 70.3
Pressure Level Heating dB(A) 71.6 72.1 72.1 72.2
Sound Cooling dB(A) 92.4 92.9 93.1 93.2
Power Level Heating dB(A) 94.4 94.9 95.1 95.2
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A R410A R410A
Precharged Amount kg 16.0 + 16.0 + 14.0 + 10.0 16.0 + 16.0 + 16.0 + 10.0 16.0 + 16.0 + 16.0 + 13.0 16.0 + 16.0 + 16.0 + 13.0
Refrigerant in factory lbs 35.3 + 35.3 + 30.9 + 22.0 35.3 + 35.3 + 35.3 + 22.0 35.3 + 35.3 + 35.3 + 28.7 35.3 + 35.3 + 35.3 + 28.7
t-CO2eq 116.9 121.1 127.3 127.3
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Number of maximum connectable indoor units 64 64 64 64
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design.
Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*1 Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
*2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination.
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
066 / 067
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION
HP 90 92 94 96
Combination Unit ARUN900LTE5 ARUN920LTE5 ARUN940LTE5 ARUN960LTE5
ARUN240LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
Model Name ARUN240LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
Independent Unit
ARUN240LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
ARUN180LTE5 ARUN200LTE5 ARUN220LTE5 ARUN240LTE5
kW 252.0 257.6 263.2 268.8
Cooling (Rated) Btu/h*1 859,900 879,000 898,100 917,200
Capacity Btu/h*2 865,100 884,500 903,600 922,800
kW 279.5 285.8 292.1 297.0
Heating (Rated)
Btu/h 953,700 975,200 996,700 1,013,600
Cooling (Rated) kW 61.23 62.58 65.12 67.03
Input
Heating (Rated) kW 68.60 72.06 74.08 75.39
COP Cooling (Rated) 4.12 4.12 4.04 4.01
COP Heating (Rated) 4.07 3.97 3.94 3.94
Power Factor Rated - 0.93 0.93 0.93 0.93
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL code RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037
Heat Exchanger Wide Louver Plus Wide Louver Plus Wide Louver Plus Wide Louver Plus
Compressor Motor Output x Number W x No. (5,300 x 7) + (4,200 x 1) 5,300 x 8 5,300 x 8 5,300 x 8
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W 900 x 8 900 x 8 900 x 8 900 x 8
m3/min 320 x 4 320 x 4 320 x 4 320 x 4
Air Flow Rate (High)
Fan ft3/min 11,301 x 4 11,301 x 4 11,301 x 4 11,301 x 4
External Static Pressure (Max, Pa) 80 80 80 80
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) 22.2 (7/8) 22.2 (7/8) 22.2 (7/8) 22.2 (7/8)
Connections Gas Pipe mm (inch) 53.98 (2-1/8) 53.98 (2-1/8) 53.98 (2-1/8) 53.98 (2-1/8)
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 4 (1,240 x1,690 x 760) x 4 (1,240 x1,690 x 760) x 4 (1,240 x1,690 x 760) x 4
Net Weight kg (283 x 3) + (261 x 1) (283 x 3) + (281 x 1) (283 x 3) + (281 x 1) (283 x 4)
Sound Cooling dB(A) 70.3 70.4 70.9 71.0
Pressure Level Heating dB(A) 72.2 72.5 72.7 73.0
Sound Cooling dB(A) 93.4 93.6 93.6 94.0
Power Level Heating dB(A) 95.3 95.4 95.6 96.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A R410A R410A
Precharged Amount kg 16.0 + 16.0 + 16.0 + 13.0 16.0 + 16.0 + 16.0 + 14.0 16.0 + 16.0 + 16.0 + 14.0 16.0 + 16.0 + 16.0 + 16.0
Refrigerant in factory lbs 35.3 + 35.3 + 35.3 + 28.7 35.3 + 35.3 + 35.3 + 30.9 35.3 + 35.3 + 35.3 + 30.9 35.3 + 35.3 + 35.3 + 35.3
t-CO2eq 127.3 129.4 129.4 133.6
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Number of maximum connectable indoor units 64 64 64 64
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design.
Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*1 Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
*2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination.
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
MULTI V 5 HEAT PUMP
ARUN221LTE5 / ARUN241LTE5
ARUN261LTE5
HP 22 24 26'
Combination Unit ARUN221LTE5 ARUN241LTE5 ARUN261LTE5
Model Name ARUN120LTE5 ARUN120LTE5 ARUN140LTE5
Independent Unit
ARUN100LTE5 ARUN120LTE5 ARUN120LTE5
kW 61.6 67.2 72.8
Cooling (Rated) Btu/h*1 210,200 229,300 248,400
Capacity Btu/h*2 211,500 230,700 249,800
kW 69.3 75.6 81.9
Heating (Rated)
Btu/h 236,500 258,000 279,500
Cooling (Rated) kW 13.6 15.81 17.02
Input
Heating (Rated) kW 13.8 16.12 17.84
COP Cooling (Rated) 4.53 4.25 4.28
COP Heating (Rated) 5.02 4.69 4.59
Power Factor Rated - 4.78 5.03 4.81
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL code RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037
Heat Exchanger Wide Louver Plus Wide Louver Plus Wide Louver Plus
Compressor Motor Output x Number W x No. 5,300 x 2 (5,300 x 2) + (4,200 x 1) (5,300 x 2) + (4,200 x 1)
Type Propeller fan Propeller fan Propeller fan
Motor Output x Number W (1,200 x 1) + (1,200 x 1) (1,200 x 1) + (1,200 x 1) (900 x 2) + (1,200 x 1)
m3/min (240 x 1) + (240 x 1) (240 x 1) + (240 x 1) (320 x 1) + (240 x 1)
Air Flow Rate (High)
Fan ft3/min (8,476 x 1) + (8,476 x 1) (8,476 x 1) + (8,476 x 1) (11,301 x 1) + (8,476 x 1)
External Static Pressure (Max, Pa) 80 80 80
Drive DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP
Pipe Liquid Pipe mm (inch) 15.88 (5/8) 15.88 (5/8) 19.05 (3/4)
Connections Gas Pipe mm (inch) 28.58 (1-1/8) 34.9 (1-3/8) 34.9 (1-3/8)
(930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1
Dimensions (W x H x D) mm x No.
+ (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1
Net Weight kg (199 x 1) + (199 x 1) (199 x 1) + (199 x 1) (221 x 1) + (199 x 1)
Sound Cooling dB(A) 61.5 62.0 62.5
Pressure Level Heating dB(A) 62.5 63.0 63.5
Sound Cooling dB(A) 81.5 82.0 83.8
Power Level Heating dB(A) 82.5 83.0 85.5
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A R410A
Precharged Amount
kg 10.0 + 10.0 10.0 + 10.0 13.0 + 10.0
Refrigerant in factory
t-CO2eq 39.7 39.7 48.01
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60
Number of maximum connectable indoor units 35 (44) 39 (48) 42 (52)
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design.
Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*1 Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
*2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination.
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
068 / 069
- Air cooled VRF Heat pump & Heat Recovery
- 9.2 ~ 33.6kW (Cooling capacity based)
- Both 1Ø, 220 ~ 240V, 50Hz and 3Ø, 380 ~ 415V, 50Hz
- Side discharge outdoor unit
- Includes the industry’s first single phase Heat Recovery system
Compact yet
powerful VRF
For premium
residences and
small offices
300m 150m (175m)
TOTAL PIPING LENGTH Longest piping length
* ARUV series : 80-100m (Depends on model) from ODU ~ IDU (Equivalent)
* ARUV series : 40-50m
(Depends on model)
Piping Capabilities
Total Piping Length 300m
@-065/')=&=&06)4506'( ?@A3)
(Equivalent) B?C@3D
@-065/')=&=&06)4506'()+H'5,)#/')I,+07() EA3
P<-01&'&-0+4)+==4&7+'&-0R BFA3D
Height difference between EA3G
ODU ~ IDU B@A3GGD
Height difference between IDU ~ IDU ?@3
* In case of outdoor unit installed lower than indoor unit
** In case of outdoor unit installed upper than indoor unit between ODU ~ IDU
* ARUV series : 15m
Height Difference
50m
Combination of Cooling,
Heating and Hot Water Solution
Reliability
INDOOR UNIT
HYDRO KIT
MULTI V S
Heat Recovery
Convenience ※ Heat Pump and Recovery are separated models.
070 / 071
OUTDOOR UNITS _ MULTI V S _ KEY FEATURES
ENERGY SAVINGS
EER / COP / Part Load Inverter Twin Rotary &
Cost savings with energy efficiency Inverter Scroll Compressor
Heat Pump Adapted High Efficient Compressor according to Capacity
EER (Cooling) COP (Heating) Inverter Twin Rotary Inverter scroll compressor
(12.1kW ~ 15.5kW) (22.4kW ~ 33.6kW)
Compressor Efficiency Comparison
43%
Efficiency
Scroll Compressor
16% 3.90 5.30 Rotary Compressor
3.35 3.71
20
Enhanced comfort and up to 23% energy savings with - Down to 15Hz : Part load efficiency improvement 15
Conventional
MULTI V load control 6 Bypass Valve
Compressor reliability is maximized with 6 Bypass Valve
MULTI V S changes indoor discharge air temperature continuously - Prevent compressor damage due to excessively compressed refrigerant more
according to load, to save energy. efficiently than 4 Bypass valve
Power
Input
Optimal Heat Exchanger
Maximize Efficiency according to different Heat Exchanger
※ Indoor air discharge temperature
Until 20 minutes after startup operation path by cooling and heating
- Energy efficiency increased by 3-step Smart Load Control during startup phase
- Discharge air temperature adjusted according to outdoor and indoor temperature
- Comfort level in cooling / heating operations ensured
Variable Heat Exchanger Circuit intelligently selects the optimal
path for both heating and cooling operations. With this smart path
Max. 10% Energy saving selection technology, an average of 6% increase in the efficiency of
both operations has been achieved. The paths number and circuit
Real Time Operation velocity are adjusted to match temperatures and operation modes in
Basic Operation Smart Load Control
order to maximize efficiency instead of compromising efficiency for
3°C 10°C each operation when the number and direction of paths are fixed
Refrigerant Refrigerant
independently of temperature operation mode.
20°C 20°C
3°C 3°C
Refrigerant Refrigerant
Fixed heat
35°C 35°C exchanger circuit
Cooling Heating
Fixed refrigerant temperature Variable refrigerant temperature Efficiency performance Efficiency up due to Fin shape
Efficiency
Max. 13% Energy saving Improved heat exchanger efficiency of up to 28%
Conventional Wide Louver Plus Fin
※ How to set up : By dip switch in outdoor unit (Referred to Product Data Book) Factory default setting is Off. Heating
※ ESEER (European seasonal energy efficiency Ratio) conditions based on 15.5kW unit Cooling 100% Cooling 128%
- Outdoor temperature condition :
EER 100% / 75% / 50% / 25% = 35°C (DB) / 30°C (DB) / 25°C (DB) / 20°C (DB) Cooling
- Indoor temperature condition : 27°C (DB) / 19°C (WB) Heating 100% Heating 123%
※ Dual sensing (Temperature & humidity) Smart Load Control is possible with Remote controller
Previous Design Number of
PTEMTB100 (White) /PREMTBB10 (Black) (Fixed) circuit
RELIABILITY
Reliable Refrigerant Components
LG technology allows for superior performance and component durability
Refrigerant
❶ Cyclonic oil separator Refrigerant
+ Oil
- Highly reliable and efficient oil separation by
centrifuge using cyclonic methods Cyclone
Centrifuges
- High collection efficiency as well as outstanding
Oil
resistance to high temperature and pressure Oil Separator
40% 20%
❸ BLDC Fan Motor
Efficiency (%)
100
BLDC
Motor
- The BLDC Fan motor is more efficient than a conventional
50
AC motor, offering an additional 40% energy savings AC
at low speeds and 20% at high speeds Motor
500 1,000
Motor Speed (RPM)
Aluminum fin
072 / 073
OUTDOOR UNITS _ MULTI V S _ KEY FEATURES
MULTI V S inverter technology and sub cooling control circuit For enhanced efficiency, new axial fan boasts higher air volume, increased
technology allows greater piping length and outstanding elevation static pressure and decreased noise.
differences. A cooling system can be implemented more flexibly in a
shop, office and even high-rise building, reducing the designer’s work
Fan Technology
time and providing more efficient design.
The new axial fan has a mogul trailing edge, narrow hub blade and reverse hub,
this provides a high efficiency, low noise, wide fan, as well as improving the air
Piping Capabilities (ARUN series) flow rate.
Reverse
300m Mogul hub
Total piping length trailing edge
50m 526mm
ODU ~ IDU
Height Narrow
150m difference hub blade
(1Ø) 4 / 5HP (1Ø) 5 / 6HP
(175m) (3Ø) 4 / 5 / 6 / 8HP
Longest
pipe length
15m
IDU ~ IDU Super cannon fan increases the air volume in 50 CMM and the noise level is
(Equivalent)
Height decreased by 4dB(A).
difference
Grooved
suction surface
Tip vortex
suppressor
Fan RPM
control
+ + (Fan Max
RPM Up)
Fan Shroud
390
360
Serial number
Model Type
S : Standard 4 holes for Anchor Bolts (M10)
L : Compact C A
330 (34) 26 950
Air Discharge Type C
(7) 81 26 97 82 244
S : Side Discharge
Electrical Ratings 5 5
L : 3Ø, 380-415V, 50Hz
5 5
G : 1Ø, 220-240V, 50Hz
834
Total Cooling Capacity in Horse Power(HP) unit
660
627
EX) 8HP → '080', 10HP → '100'
3
141 466
476
Combination of Inverter Type and Cooling Only
24
or Heat Pump B B B
83
N : Inverter and H/P, V : Inverter and C/O 51 148
1 64
2 4
MULTI V System Outdoor Unit using R410A 416
40
111
291
276
Outdoor Units Function 5-1.D. Ø20 holes for drain connection 91
250 696
Category Functions MULTI V S
A
Variable Path of Outdoor Unit HEX -
HiPORTM (High Pressure Oil Return) -
Key Refrigerant
Humidity Sensor -
Components
Corrosion Resistance Black Fin ○
Oil Sensor -
Dual Sensing -
3D View
Low Noise Operation ○
Hgih Static Mode of Outdoor Unit Fan ○
[Unit : mm] Piping
620
Partial Defrosting - Direction
14
-
390
360
Special Function (Fan reverse rotation)
Indoor Cooling Comfort Mode Based
○
Outdoor Temperature C A
Smart Load Control (SLC) 4 holes for Anchor Bolts (M10)
(Changing indoor discharge air ○
temperature according to load) C
A 950
330 26
Outdoor Unit Control Refer to
ARUB060GSS4 only 90
C
Humidity
Defrost / Deicing ○
High Pressure Switch ○
Phase Protection ○ 5
1380
Soft Start ○
80
80
52
Test Run Function -
25 26
52
B 1 6 7
AC Ez (Simple Controller) PQCSZ250S0 96 B 96
536
557
B 25 8
○ 3D View 81
074 / 075
OUTDOOR UNITS _ MULTI V S _ SPECIFICATION
HP 5 6
Model Name Combination Unit ARUV050GSD5 ARUV060GSD5
kW 14.5 16.0
Cooling
Btu/h 49,500 54,600
Capacity (Rated)
kW - -
Heating
Btu/h - -
Cooling kW 3.62 4.50
Input (Rated)
Heating kW - -
COP Cooling (Rated) 4.01 3.56
COP (Rated) - -
Power Factor Rated - 0.93 0.93
Casing Color Warm Gray + RAL 7044 Warm Gray + RAL 7044
Heat Exchanger Wide Louver Plus Wide Louver Plus
Type LG Inverter Scroll LG Inverter Scroll
Piston Displacement cm3/rev 31.6 31.6
Number of Revolution rev/min
Compressor Motor Output x Number W x No. 3,198 x 1 3,198 x 1
Starting Method DC Inverter Starting DC Inverter Starting
Oil Type FW68D FW68D
Oil Charge 1,100 1,100
Type Axial Flow Fan Axial Flow Fan
Motor Output x Number W 198 x 1 198 x 1
m3/min 80 80
Fan Air Flow Rate (High)
ft3/min 2,825 2,825
Drive DC INVERTER DC INVERTER
Discharge Side / Top Side Side
Liquid mm (inch) 9.52 (3/8) 9.52 (3/8)
Pipe Connections
Gas mm (inch) 15.88 (5/8) 19.05 (3/4)
mm 950 x 834 x 330 950 x 834 x 330
Dimensions (W x H x D)
inch 37-13/32 x 32-27/32 x 13 37-13/32 x 32-27/32 x 13
Net Weight kg 67 67
Cooling dB(A) 53 56
Sound Pressure Level
Heating dB(A) - -
Sound Power Level dB(A) - -
High pressure protection - Low pressure sensor Low pressure sensor
Over-heat protection / Over-heat protection / Fan driver overload
Protection Devices Compressor / Fan -
Fan driver overload protector protector
Inverter - Over-heat protection / Over-current protection Over-heat protection / Over-current protection
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A
kg 2.0 2.0
Refrigerant Precharged Amount
lbs 4.4 4.4
Control Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50
Number of maximum connectable indoor units 8 9
Note
1. Eurovent Test Condition : Type of indoor unit connected is only Ceiling Concealed Duct.
- Refer to EUROVENT certification regulation for more detail test conditions.
- Refer to EUROVENT website for test values connected Ceiling Cassette type indoors.
2. Performances are based on the following conditions :
- Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
- Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
3. The maximum combination ratio is 160%. (the maximum combination ratio of ARUN050GSL0 is 130%.)
4. Wiring cable size must comply with the applicable local and national codes.
5. Due to our policy of innovation some specifications may be changed without notification.
6. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
7. Power factor could vary less than ±1% according to the operating conditions.
8. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
MULTI V S HEAT PUMP
ARUN050GSS5 / ARUN060GSS5
HP 5 6
Model Name Combination Unit ARUN050GSS5 ARUN060GSS5
kW 14.0 15.5
Cooling Btu/h*1 47,800 52,900
Capacity (Rated) Btu/h*2 49,500 54,800
kW 16.0 18.0
Heating
Btu/h 54,600 61,400
Cooling kW 3.33 3.97
Input (Rated)
Heating kW 3.48 4.29
COP Cooling (Rated) 4.20 3.90
COP (Rated) Heating (Rated) 4.60 4.20
Power Factor Rated - 0.93 0.93
Casing Color Warm Gray + RAL 7044 Warm Gray + RAL 7044
Heat Exchanger Wide Louver Plus Wide Louver Plus
Type LG Inverter Scroll LG Inverter Scroll
Piston Displacement cm3/rev 31.6 31.6
Motor Output x Number W x No. 3,198 x 1 3,198 x 1
Compressor
Starting Method DC Inverter Starting DC Inverter Starting
Oil Type FW68D FW68D
Oil Charge cc 1,100 1,100
Type Axial Flow Fan Axial Flow Fan
Motor Output x Number W 198 x 1 198 x 1
m3/min 80 80
Fan Air Flow Rate (High)
ft3/min 2,825 2,825
Drive DC INVERTER DC INVERTER
Discharge Side / Top Side Side
Liquid mm (inch) 9.52 (3/8) 9.52 (3/8)
Pipe Connections
Gas mm (inch) 15.88 (5/8) 19.05 (3/4)
mm 950 x 834 x 330 950 x 834 x 330
Dimensions (W x H x D)
inch 37-13/32 x 32-27/32 x 13 37-13/32 x 32-27/32 x 13
Net Weight kg 72 72
Cooling dB(A) 57 57
Sound Pressure Level
Heating dB(A) 60 63
Sound Power Level dB(A) - -
High pressure sensor / High pressure sensor /
High pressure protection -
High pressure switch High pressure switch
Over-heat protection / Over-heat protection /
Protection Devices Compressor/Fan -
Fan driver overload protector Fan driver overload protector
Over-heat protection / Over-heat protection /
Inverter -
Over-current protection Over-current protection
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A
kg 2.4 2.4
Refrigerant Precharged Amount
lbs 5.3 5.3
Control Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50
Number of maximum connectable indoor units 10 13
Note
1. Eurovent Test Condition : Type of indoor unit connected is only Ceiling Concealed Duct.
- Refer to EUROVENT certification regulation for more detail test conditions.
- Refer to EUROVENT website for test values connected Ceiling Cassette type indoors.
2. Performances are based on the following conditions :
- *1 Cooling : Indoot Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
- *2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
- *Heating : Indoot Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
3. The maximum combination ratio is 160%. (the maximum combination ratio of ARUN050GSL0 is 130%.)
4. Wiring cable size must comply with the applicable local and national codes.
5. Due to our policy of innovation some specifications may be changed without notification.
6. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
7. Power factor could vary less than ±1% according to the operating conditions.
8. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
076 / 077
OUTDOOR UNITS _ MULTI V S _ SPECIFICATION
HP 5 6
Model Name Combination Unit ARUN050LSS5 ARUN060LSS5
kW 14.0 15.5
Cooling Btu/h*1 47,800 52,900
Capacity (Rated) Btu/h*2 49,500 54,800
kW 16.0 18.0
Heating
Btu/h 54,600 61,400
Cooling kW 3.33 3.97
Input (Rated)
Heating kW 3.48 4.29
COP Cooling (Rated) 4.20 3.90
COP Heating (Rated) 4.60 4.20
Power Factor Rated - 0.93 0.93
Casing Color Warm Gray + RAL 7044 Warm Gray + RAL 7044
Heat Exchanger Wide Louver Plus Wide Louver Plus
Type LG Inverter Scroll LG Inverter Scroll
Piston Displacement cm3/rev 31.6 31.6
Motor Output x Number W x No. 3,198 x 1 3,198 x 1
Compressor
Starting Method DC Inverter Starting DC Inverter Starting
Oil Type FW68D FW68D
Oil Charge cc 1,100 1,100
Type Axial Flow Fan Axial Flow Fan
Motor Output x Number W 198 x 1 198 x 1
m3/min 80 80
Fan Air Flow Rate (High)
ft3/min 2,825 2,825
Drive DC INVERTER DC INVERTER
Discharge Side / Top Side Side
Liquid mm (inch) 9.52 (3/8) 9.52 (3/8)
Pipe Connections
Gas mm (inch) 15.88 (5/8) 19.05 (3/4)
mm 950 x 834 x 330 950 x 834 x 330
Dimensions (W x H x D)
inch 37-13/32 x 32-27/32 x 13 37-13/32 x 32-27/32 x 13
Net Weight kg 72 72
Cooling dB(A) 57 57
Sound Pressure Level
Heating dB(A) 60 63
Sound Power Level dB(A) - -
High pressure sensor / High pressure sensor /
High pressure protection -
High pressure switch High pressure switch
Over-heat protection / Over-heat protection /
Protection Devices Compressor/Fan -
Fan driver overload protector Fan driver overload protector
Over-heat protection / Over-heat protection /
Inverter -
Over-current protection Over-current protection
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A
kg 2.4 2.4
Refrigerant Precharged Amount
lbs 5.3 5.3
Control Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50
Number of maximum connectable indoor units 10 13
Note
1. Eurovent Test Condition : Type of indoor unit connected is only Ceiling Concealed Duct.
- Refer to EUROVENT certification regulation for more detail test conditions.
- Refer to EUROVENT website for test values connected Ceiling Cassette type indoors.
2. Performances are based on the following conditions :
- * 1 Cooling : Indoot Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
- * 2 Cooling : Indoot Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
- *Heating : Indoot Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
3. The maximum combination ratio is 160%. (the maximum combination ratio of ARUN050GSL0 is 130%.)
4. Wiring cable size must comply with the applicable local and national codes.
5. Due to our policy of innovation some specifications may be changed without notification.
6. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
7. Power factor could vary less than ±1% according to the operating conditions.
8. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
MULTI V S HEAT PUMP
ARUN080LSS0 / ARUN100LSS0 / ARUN120LSS0
HP 8 10 12
Model Name Combination Unit ARUN080LSS0 ARUN100LSS0 ARUN120LSS0
kW 22.4 28.0 33.6
Cooling (Rated) Btu/h*1 76,400 95,900 114,700
Capacity
Btu/h*2 78,300 98,100 117,300
Heating (Rated) kW 25.2 31.5 37.8
Cooling (Rated) kW 5.89 7.09 9.08
Input
Heating (Rated) kW 6.00 7.41 9.95
COP Cooling (Rated) 3.80 3.95 3.70
COP Heating (Rated) 4.20 4.25 3.80
Color (General) Warm Gray Warm Gray Warm Gray
Exterior
RAL Code (Classic), General RAL 7044 RAL 7044 RAL 7044
Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 1 (Inverter) x 1 (Inverter) x 1
Compressor Motor Output x Number W x No. 4,200 x 1 5,300 x 1 5,300 x 1
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 2,400 2,600 3,400
Type Propeller fan Propeller fan Propeller fan
Motor Output x Number W x No. 124 x 2 250 x 2 250 x 2
Fan Air Flow Rate (High) m3/min x No. 140 x 1 190 x 1 190 x 1
Drive DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top Side Side Side
Liquid Pipe mm (inch) Ø9.52 (3/8) Ø9.52 (3/8) Ø12.7 (1/2)
Pipe Connection
Gas Pipe mm (inch) Ø19.05 (3/4) Ø22.2 (7/8) Ø28.58 (1-1/8)
Dimensions (W x H x D) mm 950 x 1,380 x 330 1,090 x 1,625 x 380 1,090 x 1,625 x 380
Dimensions (W x H x D) - Shipping mm 1,140 x 1,462 x 461 1,215 x 1,795 x 500 1,215 x 1,795 x 500
Net Weight kg 115 144 157
Shipping Weight kg 127 160 173
Cooling dB(A) 57.0 58.0 60.0
Sound Pressure Level
Heating dB(A) 57.0 58.0 60.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 3.5 4.5 6.0
Refrigerant factory
t-CO2eq 7.3 9.4 12.5
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 13 16 20
Note
1. Eurovent Test Condition : Type of indoor unit connected is only Ceiling Concealed Duct.
- Refer to EUROVENT certification regulation for more detail test conditions.
- Refer to EUROVENT website for test values connected Ceiling Cassette type indoors.
2. Performances are based on the following conditions :
- * 1 Cooling : Indoot Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
- * 2 Cooling : Indoot Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
- *Heating : Indoot Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
3. The maximum combination ratio is 160%. (the maximum combination ratio of ARUN050GSL0 is 130%.)
4. Wiring cable size must comply with the applicable local and national codes.
5. Due to our policy of innovation some specifications may be changed without notification.
6. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
7. Power factor could vary less than ±1% according to the operating conditions.
8. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
078 / 079
OUTDOOR UNITS _ MULTI V S _ SPECIFICATION
HP 6
Model Name Combination Unit ARUB060GSS4
kW 15.5
Cooling (Rated)
Capacity Btu/h 52,900
Heating (Rated) kW 18.0
Cooling (Rated) kW 3.97
Input
Heating (Rated) kW 4.10
EER 3.90
COP Rated Capacity 4.39
Color Warm Gray
Exterior
RAL Code (Classic) RAL 7044
Heat Exchanger Type Wide Louver Plus
Type Hermetically Sealed Scroll
Combination x No. (Inverter) x 1
Compressor Motor Output x Number W x No. 4,200 x 1
Oil Type FVC68D (PVE)
Oil Charge cc 1,700
Type Axial Flow Fan
Motor Output x Number W x No. 124 x 2
Fan Air Flow Rate (High) m3/min x No. 110 x 1
Drive DC INVERTER
Discharge Side / Top Side
Liquid Pipe mm (inch) Ø9.52 (3/8)
Pipe Connection #1 Low Pressure Gas Pipe mm (inch) Ø19.05 (3/4)
High Pressure Gas Pipe mm (inch) Ø15.88 (5/8)
Dimensions (W x H x D) mm x No. (950 x 1,380 x 330) x 1
Dimensions (W x H x D) - shipping mm x No. (1,140 x 1,549 x 466) x 1
Net Weight kg x No. 118 x 1
Shipping Weight kg x No. 132 x 1
Cooling dB(A) 56.0
Sound Pressure Level
Heating dB(A) 58.0
Cooling dB(A) 76.0
Sound Power Level
Heating dB(A) 78.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A
Precharged Amount in
kg 3.5
Refrigerant factory
t-CO2eq 7.3
Control Electronic Expansion Valve
Power Supply Ø, V, Hz 1, 220-240, 50
Number of Maximum Connectable Indoor Units 13
Note
1. Eurovent Test Condition : Type of indoor unit connected is only Ceiling Concealed Duct.
- Refer to EUROVENT certification regulation for more detail test conditions.
- Refer to EUROVENT website for test values connected Ceiling Cassette type indoors.
2. Performances are based on the following conditions :
- * 1 Cooling : Indoot Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
- * 2 Cooling : Indoot Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
- *Heating : Indoot Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
3. The maximum combination ratio is 160%. (the maximum combination ratio of ARUN050GSL0 is 130%.)
4. Wiring cable size must comply with the applicable local and national codes.
5. Due to our policy of innovation some specifications may be changed without notification.
6. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is
measured on the rated condition in the reverberation rooms by ISO 3741 standard. Therefore, these values can be increased
owing to ambient conditions during operation.
7. Power factor could vary less than ±1% according to the operating conditions.
8. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
OUTDOOR UNITS _ MULTI V S _ APPLICATION GUIDE
MULTI V S
Energy Savings
Energy consumption can be reduced as indoor heat is absorbed and transferred to hot water supply.
Conventional
Absorbed heat is released to outdoor air.
Heat
Absorption
Conventional
Hot water
Boiler Domestic
(Gas or Electric) Hot Water Tank Hot Water Supply Cooling
Heat Transfer
HR Unit
Heat
Absorption
Heat Recovery
Hot water
080 / 081
- Water Cooled VRF Heat Pump & Heat Recovery
- 22.4 ~ 201.6kW (Cooling capacity based)
- 3Ø, 380 ~ 415V, 50Hz
- Outdoor unit installed indoor
Economical,
efficient system
Longest piping length after 1st branch
40m (Conditional application)
40m
Height between
IDU ~ IDU
50m
Height between
ODU ~ IDU
Energy savings
Outdoor Wind
Temp
Heating based
Space savings Simultaneous operation
External energy saving by between
heat recovery system
Cooling based
Simultaneous operation
Geothermal Application
37°C
Convenient Cooling
32°C
Tower
installation
Water
Pump
Control
Room 1 Room 2 Room 3 Panel
082 / 083
OUTDOOR UNITS _ MULTI V S _ KEY FEATURES
Maximum COP
COP
1,800
1,600
Average
energy saving
1,400
1,200 12%
1,000
800
600
400
200
Previous Model MULTI V WATER IV
Pump
Machine Room
MULTI V WATER IV
LG’s 4th Generation Inverter Compressor
Efficiency (EER)
HP 8 10 14 20 22 24 28 30 34 40 42 ~ 60 62 ~ 80
kW 22.4 28 39.2 56 61.6 67.2 78.4 84 95.2 112 117.6 ~ 168 173.6 ~ 224
Variable Water
Flow Control Valve
LG
CoolingTower DC 0 ~ 10V
1 Unit 2 Units 3 Units 4 Units
Inverter
Pump
Longest Piping Length
Geothermal
Sufficient pipes length limitation in design and Installation
PWFCKN00 of immense variety of building
River / Sea
Provide flexible installation up to 300m of total piping length.
As water pipes are not connected to indoor units, users are free
from water leakage problems.
Total Water Flow (m3)
4,439
Compact Size
Project Example : 63F (Pump : 20,064 LPM, 42.4mAq x 4ea) Thanks to compact size of product, it provides more space
1) Inverter pump with MULTI V WATER and variable water flow control kit for commercial or public use as much as possible.
2) Constant pump (Step control) with Water cooled VRF
The optimal design of the compact, lightweight outdoor unit enables
10 years energy cost ($) double stacking, which results in 50% savings in installation space.
Total Water Flow (m3)
084 / 085
OUTDOOR UNITS _ MULTI V WATER IV _ TECHNICAL DATA
operation
30
30
Electrical Ratings
25
L : 3Ø, 380 ~ 415 V, 50Hz
25
20
Total Cooling Capacity in Horse
20
Power (HP) unit
15
EX) 10HP → '100'
15 Range for
10 operation
Range for
Combination of Inverter Type and Cooling Only operation
or Heat Pump 10 -5
10 15 20 25 30 10 15 20 25 30
N: Inverter and H/P
Indoor Temperature (°C WB) Indoor Temperature (°C DB)
MULTI V Water System with Outdoor unit
using R410A
Note
1. These figures assume the following operating conditions:
2. Equivalent piping length :7.5m
3. Level difference : 0m
Outdoor Units Function
Category Functions MULTI V WATER IV
Variable Path of Outdoor unit HEX -
HiPORTM (High Pressure Oil Return) ○ Position of Sound Pressure Level Measuring
Key Refrigerant
Humidity Sensor -
Components
Corrosion Resistance Black Fin -
Oil Sensor ○
Dual Sensing -
Low Noise Operation -
Hgih Static Mode of Outdoor Unit Fan -
Partial Defrosting -
Auto Dust Cleaning of Outdoor Unit
-
Useful Function (Fan reverse rotation)
Indoor Cooling Comfort Mode Based
-
Outdoor Temperature
Smart Load Control (SLC)
(Changing indoor discharge air -
temperature according to load)
Note
Outdoor Unit Control Refer to Humidity - 1. Data is valid at free field condition
Defrost / Deicing - 2. Data is valid at nominal operating condition
3. Sound level will vary depending on a range of factors such as the construction
High Pressure Switch ○ (Acoustic absorption coefficient) of particular room in which the equipment is installed
4. Sound level can be increased in static pressure mode or air guide application.
Phase Protection ○
Reliability Restart Delay (3-minutes) ○
Self Diagnosis ○
Soft Start ○
Test Run Function ○
Optional Accessories
AC Ez (Simple Controller) PQCSZ250S0 No. Name Model
AC Ez Touch PACEZA000 ARBLN01621
AC Smart IV PACS4B000 ARBLN03321
Central Controller AC Smart 5 PACS5A000
1 Y branch pipe ARBLN07121
ACP (Advanced Control Platform) IV PQCPC22A0
ARBLN14521
ACP (Advanced Control Platform) 5 PACP5A000
AC Manager 5 PACM5A000 ARBLN23220
IO Module (ODU Dry Contact) PVDSMN000 3 Connection pipe of Outdoor Units ARCNN31
9. Install a service port to clean the heat exchanger at the each end
of the water inlet and outlet.
Liquid pipe 79
Gas pipe 79
High/Low pressure 10. It is recommended to install the flow switch to the water
Common 79
Water pipe outlet
collection pipe system connecting to the outdoor unit. (Flow switch
58
acts as the 1st protection device when the heat water is not
997
supplied.)
913
828
742
635
Water
pipe inlet product with default set value to satisfy the minimum flow rate of
169
this product. (The minimum flow rate range of this product is 50%.)
95
345 250
378
500 12. To protect the water cooling type product, you must install a
755
strainer with 50 mesh or more on the heat water supply pipe.
If not installed, it can result in damage of heat exchanger by the
following situation.
Individual Installation
1) Heat water supply within the plate type heat exchanger is
composed of multiple small paths.
2) If you do not use a strainer with 50 mesh or more, alien
particles can partially block the water paths.
3) When running the heater, the plate type heat exchanger plays
the role of the evaporator, and at this time, the temperature
of the refrigerant side drops to drop the temperature of the
heat water supply, which can result in icing point in the water
paths.
4) As the heating process progresses, the water paths can
be partially frozen to lead to damage in plate type heat
exchanger.
5) As a result of the damage of the heat exchanger from the
freezing, the refrigerant side and the heat water source side
will be mixed to make the product unusable.
086 / 087
OUTDOOR UNITS _ MULTI V WATER IV _ REFERENCE SITE
REFERENCE SITE
Bouygues Challenger
LG MULTI V WATER Solution with Geothermal Application
Site Information
The industrial group Bouygues was established in France in 1952. It now maintains operations in 80 countries and employs more than 131,000 people.
In 1988, after two years of construction, the new headquarters for Bouygues Construction was officially opened for business. Named Challenger, the
complex became a technological showcase for late 20th century architecture.
LG Solution
Bouygues decided to convert their headquarters into an eco-friendly building by significantly reducing its energy footprint. The LG MULTI V Water system
was chosen as the ideal HVAC solution for this project. The system not only saves energy but also reduces water usage as it recycles water in order to
regulate the temperature of the building. With LG’s advanced technology, the building’s water consumption was reduced by more than 70 percent.
OUTDOOR UNITS _ MULTI V WATER IV _ SPECIFICATION
HP 8 10 14
Combination Unit ARWN080LAS4 ARWN100LAS4 ARWN140LAS4
Model Name
Independent Unit ARWN080LAS4 ARWN100LAS4 ARWN140LAS4
kW 22.4 28.0 39.2
Cooling (Rated)
Capacity Btu/h 76,800 95,900 133,800
Heating (Rated) kW 25.2 31.5 44.1
Cooling (Rated) kW 3.86 5.09 7.84
Input
Heating (Rated) kW 4.2 5.34 8.17
EER 5.80 5.50 5.00
COP Rated Capacity 6.00 5.90 5.40
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 10.7 15.8 28.6
Rated Water Flow LPM 77 96 135
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 1 (Inverter) x 1 (Inverter) x 1
Motor Output x
Compressor W x No. 4,200 x 1 4,200 x 1 4,200 x 1
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 2,800 2,800 2,800
Refrigerant Liquid Pipe mm (inch) Ø9.52 (3/8) Ø9.52 (3/8) Ø12.7 (1/2)
Connecting Pipes Gas Pipe mm (inch) Ø22.2 (7/8) Ø22.2 (7/8) Ø25.4 (1)
Inlet A (inch) 40A(PT 1-1/2) (Internal Thread) 40A(PT 1-1/2) (Internal Thread) 40A(PT 1-1/2) (Internal Thread)
Water Connecting
Outlet A (inch) 40A(PT 1-1/2) (Internal Thread) 40A(PT 1-1/2) (Internal Thread) 40A(PT 1-1/2) (Internal Thread)
Pipes
Drain Outlet A (inch) 20A(PT 3/4) (External Thread) 20A(PT 3/4) (External Thread) 20A(PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 1 (755 x 997 x 500) x 1 (755 x 997 x 500) x 1
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 1 (804 x 1,143 x 630) x 1 (804 x 1,143 x 630) x 1
Net Weight kg x No. 127 x 1 127 x 1 127 x 1
Shipping Weight kg x No. 137 x 1 137 x 1 137 x 1
Sound Cooling dB(A) 47.0 50.0 58.0
Pressure Level Heating dB(A) 51.0 53.0 57.0
Sound Cooling dB(A) 59.0 62.0 70.0
Power Level Heating dB(A) 63.0 65.0 69.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 5.8 5.8 5.8
Refrigerant Factory
t-CO2eq 12.1 12.1 12.1
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 13 (20) 16 (25) 23 (35)
Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination (160% ~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
088 / 089
OUTDOOR UNITS _ MULTI V WATER IV _ SPECIFICATION
HP 20 16 18
Combination Unit ARWN200LAS4 ARWN160LAS4 ARWN180LAS4
Model Name ARWN080LAS4 ARWN100LAS4
Independent Unit ARWN200LAS4
ARWN080LAS4 ARWN080LAS4
kW 56.0 44.8 50.4
Cooling (Rated)
Capacity Btu/h 191,00 153,600 172,700
Heating (Rated) kW 63.0 50.4 56.7
Cooling (Rated) kW 11.20 7.72 8.95
Input
Heating (Rated) kW 11.67 8.40 9.54
EER 5.00 5.80 5.63
COP Rated Capacity 5.40 6.00 5.94
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 30.1 10.7 + 10.7 15.8 + 10.7
Rated Water Flow LPM 192 77 + 77 96 + 77
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 1 (Inverter) x 2 (Inverter) x 2
Motor Output x
Compressor W x No. 5,300 x 1 4,200 x 2 4,200 x 2
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 3,000 5,600 5,600
Refrigerant Liquid Pipe mm (inch) Ø12.7 (1/2) Ø12.7 (1/2) Ø12.7 (1/2)
Connecting Pipes Gas Pipe mm (inch) Ø28.58 (1-1/8) Ø28.58 (1-1/8) Ø28.58 (1-1/8)
40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Inlet A (inch) 40A (PT 1-1/2) (Internal Thread)
(Internal Thread) (Internal Thread)
Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Pipes Outlet A (inch) 40A (PT 1-1/2) (Internal Thread)
(Internal Thread) (Internal Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 1 (755 x 997 x 500) x 2 (755 x 997 x 500) x 2
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 1 (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2
Net Weight kg x No. 140 x 1 127 x 2 127 x 2
Shipping Weight kg x No. 150 x 1 137 x 2 137 x 2
Sound Cooling dB(A) 54.0 50.0 51.8
Pressure Level Heating dB(A) 60.0 54.0 55.1
Sound Cooling dB(A) 66.0 62.0 63.8
Power Level Heating dB(A) 72.0 66.0 67.1
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 3.0 11.6 11.6
Refrigerant Factory
t-CO2eq 6.3 24.2 24.2
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 32 (50) 26 (40) 29 (45)
Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination (160% ~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
MULTI V WATER IV HEAT PUMP
ARWN220LAS4 / ARWN240LAS4
ARWN280LAS4
HP 22 24 28
Combination Unit ARWN220LAS4 ARWN240LAS4 ARWN280LAS4
Model Name ARWN140LAS4 ARWN140LAS4 ARWN140LAS4
Independent Unit
ARWN080LAS4 ARWN100LAS4 ARWN140LAS4
kW 61.6 67.2 78.4
Cooling (Rated)
Capacity Btu/h 210,600 229,700 267,600
Heating (Rated) kW 69.3 75.6 88.2
Cooling (Rated) kW 11.70 12.93 15.68
Input
Heating (Rated) kW 12.37 13.51 16.34
EER 5.26 5.20 5.00
COP Rated Capacity 5.60 5.60 5.40
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 28.6 + 10.7 28.6 + 15.8 28.6 + 28.6
Rated Water Flow LPM 135 + 77 135 + 96 135 + 135
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 2 (Inverter) x 2 (Inverter) x 2
Motor Output x
Compressor W x No. 4,200 x 2 4,200 x 2 4,200 x 2
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 5,600 5,600 5,600
Refrigerant Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Connecting Pipes Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8)
40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Inlet A (inch)
(Internal Thread) (Internal Thread) (Internal Thread)
Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Pipes Outlet A (inch)
(Internal Thread) (Internal Thread) (Internal Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 2 (755 x 997 x 500) x 2 (755 x 997 x 500) x 2
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2
Net Weight kg x No. 127 x 2 127 x 2 127 x 2
Shipping Weight kg x No. 137 x 2 137 x 2 137 x 2
Sound Cooling dB(A) 58.3 58.6 59.0
Pressure Level Heating dB(A) 58.0 58.5 58.0
Sound Cooling dB(A) 70.3 70.6 72.0
Power Level Heating dB(A) 70.0 70.5 71.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 11.6 11.6 11.6
Refrigerant Factory
t-CO2eq 24.2 24.2 24.2
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 35 (44) 39 (48) 45 (56)
Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination (160% ~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
090 / 091
OUTDOOR UNITS _ MULTI V WATER IV _ SPECIFICATION
HP 30 34 40
Combination Unit ARWN300LAS4 ARWN340LAS4 ARWN400LAS4
Model Name ARWN200LAS4 ARWN200LAS4 ARWN200LAS4
Independent Unit
ARWN100LAS4 ARWN140LAS4 ARWN200LAS4
kW 84.0 95.2 112.0
Cooling (Rated)
Capacity Btu/h 286,700 324,900 382,200
Heating (Rated) kW 94.5 107.1 126.0
Cooling (Rated) kW 16.29 19.04 22.40
Input
Heating (Rated) kW 17.01 19.84 23.34
EER 5.16 5.00 5.00
COP Rated Capacity 5.56 5.40 5.40
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 30.1 + 15.8 30.1 + 28.6 30.1 + 30.1
Rated Water Flow LPM 192 + 96 192 + 135 192 + 192
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 2 (Inverter) x 2 (Inverter) x 2
Motor Output x
Compressor W x No. 5,300 x 1 + 4,200 x 1 5,300 x 1 + 4,200 x 1 5,300 x 2
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 5,800 5,800 6,000
Refrigerant Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Connecting Pipes Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø41.3 (1-5/8)
40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Inlet A (inch)
(Internal Thread) (Internal Thread) (Internal Thread)
Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Pipes Outlet A (inch)
(Internal Thread) (Internal Thread) (Internal Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 2 (755 x 997 x 500) x 2 (755 x 997 x 500) x 2
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2
Net Weight kg x No. (140 x 1) + (127 x 1) (140 x 1) + (127 x 1) 140 x 2
Shipping Weight kg x No. (150 x 1) + (137 x 1) (150 x 1) + (137 x 1) 150 x 2
Sound Cooling dB(A) 55.5 59.0 55.0
Pressure Level Heating dB(A) 60.8 61.0 61.0
Sound Cooling dB(A) 67.5 72.0 68.0
Power Level Heating dB(A) 72.8 74.0 74.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 8.8 8.8 6.0
Refrigerant Factory
t-CO2eq 18.4 18.4 12.5
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 49 (60) 55 (64) 64
Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination (160% ~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
MULTI V WATER IV HEAT PUMP
ARWN420LAS4 / ARWN440LAS4
ARWN480LAS4
HP 42 44 48
Combination Unit ARWN420LAS4 ARWN440LAS4 ARWN480LAS4
Model Name ARWN200LAS4 ARWN200LAS4 ARWN200LAS4
Independent Unit ARWN140LAS4 ARWN140LAS4 ARWN140LAS4
ARWN080LAS4 ARWN100LAS4 ARWN140LAS4
kW 117.6 123.2 134.4
Cooling (Rated)
Capacity Btu/h 401,700 420,800 459,000
Heating (Rated) kW 132.3 138.6 151.2
Cooling (Rated) kW 22.9 24.13 26.88
Input
Heating (Rated) kW 24.04 25.18 28.01
EER 5.14 5.11 5.00
COP Rated Capacity 5.50 5.50 5.40
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 30.1 + 28.6 + 10.7 30.1 + 28.6 + 15.8 30.1 + 28.6 + 28.6
Rated Water Flow LPM 192 + 135 + 77 192 + 135 + 96 192 + 135 + 135
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 3 (Inverter) x 3 (Inverter) x 3
Motor Output x
Compressor W x No. 5,300 x 1 + 4,200 x 2 5,300 x 1 + 4,200 x 2 5,300 x 1 + 4,200 x 2
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 8,600 8,600 8,600
Refrigerant Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Connecting Pipes Gas Pipe mm (inch) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8)
40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) +
Inlet A (inch)
40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread)
Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) +
Pipes Outlet A (inch)
40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 3 (755 x 997 x 500) x 3 (755 x 997 x 500) x 3
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3
Net Weight kg x No. (140 x 1) + (127 x 2) (140 x 1) + (127 x 2) (140 x 1) + (127 x 2)
Shipping Weight kg x No. (150 x 1) + (137 x 2) (150 x 1) + (137 x 2) (150 x 1) + (137 x 2)
Sound Cooling dB(A) 59.7 59.9 60.0
Pressure Level Heating dB(A) 62.1 62.3 62.0
Sound Cooling dB(A) 71.7 71.9 74.0
Power Level Heating dB(A) 74.1 74.3 76.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 14.6 14.6 14.6
Refrigerant Factory
t-CO2eq 30.5 30.5 30.5
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 64 64 64
Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination (160% ~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
092 / 093
OUTDOOR UNITS _ MULTI V WATER IV _ SPECIFICATION
HP 50 54 60
Combination Unit ARWN500LAS4 ARWN540LAS4 ARWN600LAS4
Model Name ARWN200LAS4 ARWN200LAS4 ARWN200LAS4
Independent Unit ARWN200LAS4 ARWN200LAS4 ARWN200LAS4
ARWN100LAS4 ARWN140LAS4 ARWN200LAS4
kW 140.0 151.2 168.0
Cooling (Rated)
Capacity Btu/h 478,100 516,000 573,300
Heating (Rated) kW 157.5 170.1 189.0
Cooling (Rated) kW 27.49 30.24 33.60
Input
Heating (Rated) kW 28.68 31.51 35.01
EER 5.09 5.00 5.00
COP Rated Capacity 5.49 5.40 5.40
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 30.1 + 30.1 + 15.8 30.1 + 28.6 + 28.6 30.1 + 30.1 + 30.1
Rated Water Flow LPM 192 + 192 + 96 192 + 192 + 135 192 + 192+ 192
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 3 (Inverter) x 3 (Inverter) x 3
Motor Output x
Compressor W x No. 5,300 x 2 + 4,200 x 1 5,300 x 2 + 4,200 x 1 5,300 x 3
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 8,800 8,800 9,000
Refrigerant Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Connecting Pipes Gas Pipe mm (inch) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8)
40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) +
Inlet A (inch)
40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread)
Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) +
Pipes Outlet A (inch)
40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 3 (755 x 997 x 500) x 3 (755 x 997 x 500) x 3
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3
Net Weight kg x No. (140 x 2) + (127 x 1) (140 x 2) + (127 x 1) 140 x 3
Shipping Weight kg x No. (150 x 2) + (137 x 1) (150 x 2) + (137 x 1) 150 x 3
Sound Cooling dB(A) 57.8 60.0 56.0
Pressure Level Heating dB(A) 63.4 62.0 62.0
Sound Cooling dB(A) 69.8 74.0 70.0
Power Level Heating dB(A) 75.4 76.0 76.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 11.8 11.8 9.0
Refrigerant Factory
t-CO2eq 24.6 24.6 18.8
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 64 64 64
Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination (160% ~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
MULTI V WATER IV HEAT PUMP
ARWN620LAS4 / ARWN640LAS4
ARWN680LAS4
HP 62 64 68
Combination Unit ARWN620LAS4 ARWN640LAS4 ARWN680LAS4
ARWN200LAS4 ARWN200LAS4 ARWN200LAS4
Model Name ARWN200LAS4 ARWN200LAS4 ARWN200LAS4
Independent Unit
ARWN140LAS4 ARWN140LAS4 ARWN140LAS4
ARWN080LAS4 ARWN100LAS4 ARWN140LAS4
kW 173.6 179.2 190.4
Cooling (Rated)
Capacity Btu/h 592,700 611,600 649,800
Heating (Rated) kW 195.3 201.6 214.2
Cooling (Rated) kW 34.10 35.33 38.08
Input
Heating (Rated) kW 35.71 36.85 39.68
EER 5.09 5.07 5.00
COP Rated Capacity 5.47 5.47 5.40
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 30.1 + 30.1 + 28.6 + 10.7 30.1 + 30.1 + 28.6 + 15.8 30.1 + 30.1 + 28.6 + 28.6
Rated Water Flow LPM 192 + 192 + 135 + 77 192 + 192 + 135 + 96 192 + 192 + 135 + 135
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 4 (Inverter) x 4 (Inverter) x 4
Motor Output x
Compressor W x No. 5,300 x 2 + 4,200 x 2 5,300 x 2 + 4,200 x 2 5,300 x 2 + 4,200 x 2
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 11,600 11,600 11,600
Refrigerant Liquid Pipe mm (inch) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8)
Connecting Pipes Gas Pipe mm (inch) Ø44.5 (1-3/4) Ø44.5 (1-3/4) Ø53.98 (2-1/8)
40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Inlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40
(Internal Thread) (Internal Thread) (Internal Thread)
Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Pipes Outlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40
(Internal Thread) (Internal Thread) (Internal Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 4 (755 x 997 x 500) x 4 (755 x 997 x 500) x 4
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4
Net Weight kg x No. (140 x 2) + (127 x 2) (140 x 2) + (127 x 2) (140 x 2) + (127 x 2)
Shipping Weight kg x No. (150 x 2) + (137 x 2) (150 x 2) + (137 x 2) (150 x 2) + (137 x 2)
Sound Cooling dB(A) 60.7 60.9 61.0
Pressure Level Heating dB(A) 64.2 64.3 63.0
Sound Cooling dB(A) 72.7 72.9 75.0
Power Level Heating dB(A) 76.2 76.3 77.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 17.6 17.6 17.6
Refrigerant Factory
t-CO2eq 36.7 36.7 36.7
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 64 64 64
Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination (160% ~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
094 / 095
OUTDOOR UNITS _ MULTI V WATER IV _ SPECIFICATION
HP 70 74 80
Combination Unit ARWN700LAS4 ARWN740LAS4 ARWN800LAS4
ARWN200LAS4 ARWN200LAS4 ARWN200LAS4
Model Name ARWN200LAS4 ARWN200LAS4 ARWN200LAS4
Independent Unit
ARWN200LAS4 ARWN200LAS4 ARWN200LAS4
ARWN100LAS4 ARWN140LAS4 ARWN200LAS4
kW 196.0 207.2 224.0
Cooling (Rated)
Capacity Btu/h 668,900 707,100 764,400
Heating (Rated) kW 220.5 233.1 252.0
Cooling (Rated) kW 38.69 41.44 44.80
Input
Heating (Rated) kW 40.35 43.18 46.68
EER 5.07 5.00 5.00
COP Rated Capacity 5.46 5.40 5.40
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 30.1 + 30.1 + 30.1 + 15.8 30.1 + 30.1 + 30.1 + 28.6 30.1 + 30.1 + 30.1 + 30.1
Rated Water Flow LPM 192 + 192 + 192 + 96 192 + 192 + 192 + 135 192 + 192 + 192 + 192
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 4 (Inverter) x 4 (Inverter) x 4
Motor Output x
Compressor W x No. 5,300 x 3 + 4,200 x 1 5,300 x 3 + 4,200 x 1 5,300 x 4
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 11,800 11,800 12,000
Refrigerant Liquid Pipe mm (inch) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8)
Connecting Pipes Gas Pipe mm (inch) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8)
40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Inlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40
(Internal Thread) (Internal Thread) (Internal Thread)
Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Pipes Outlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40
(Internal Thread) (Internal Thread) (Internal Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 4 (755 x 997 x 500) x 4 (755 x 997 x 500) x 4
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4
Net Weight kg x No. (140 x 3) + (127 x 1) (140 x 3) + (127 x 1) 140 x 4
Shipping Weight kg x No. (150 x 3) + (137 x 1) (150 x 3) + (137 x 1) 150 x 4
Sound Cooling dB(A) 59.3 61.0 57.0
Pressure Level Heating dB(A) 65.1 63.0 63.0
Sound Cooling dB(A) 71.3 75.0 71.0
Power Level Heating dB(A) 77.1 77.0 77.0
No.x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 14.8 14.8 12.0
Refrigerant Factory
t-CO2eq 30.9 30.9 25.1
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 64 64 64
Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination (160% ~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
MULTI V WATER IV HEAT RECOVERY
ARWB080LAS4 / ARWB100LAS4
ARWB140LAS4
HP 8 10 14
Combination Unit ARWB080LAS4 ARWB100LAS4 ARWB140LAS4
Model Name
Independent Unit ARWB080LAS4 ARWB100LAS4 ARWB140LAS4
kW 22.4 28.0 39.2
Cooling (Rated)
Capacity Btu/h 76,800 95,900 133,800
Heating (Rated) kW 25.2 31.5 44.1
Cooling (Rated) kW 3.86 5.09 7.84
Input
Heating (Rated) kW 4.20 5.34 8.17
EER 5.80 5.50 5.00
COP Rated Capacity 6.00 5.90 5.40
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 10.7 15.8 28.6
Rated Water Flow LPM 77 96 135
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 1 (Inverter) x 1 (Inverter) x 1
Motor Output x
Compressor W x No. 4,200 x 1 4,200 x 1 4,200 x 1
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 2,800 2,800 2,800
Liquid Pipe mm (inch) Ø9.52 (3/8) Ø9.52 (3/8) Ø12.7 (1/2)
Refrigerant
Low Pressure Gas Pipe mm (inch) Ø22.2 (7/8) Ø22.2 (7/8) Ø25.4 (1)
Connecting Pipes
High Pressure Gas Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Inlet A (inch) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread)
Water Connecting
Outlet A (inch) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread)
Pipes
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 1 (755 x 997 x 500) x 1 (755 x 997 x 500) x 1
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 1 (804 x 1,143 x 630) x 1 (804 x 1,143 x 630) x 1
Net Weight kg x No. 127 x 1 127 x 1 127 x 1
Shipping Weight kg x No. 137 x 1 137 x 1 137 x 1
Sound Cooling dB(A) 47.0 50.0 58.0
Pressure Level Heating dB(A) 51.0 53.0 57.0
Sound Cooling dB(A) 59.0 62.0 70.0
Power Level Heating dB(A) 63.0 65.0 69.0
No.x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 5.8 5.8 5.8
Refrigerant Factory
t-CO2eq 12.1 12.1 12.1
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 13 (20) 16 (25) 23 (35)
Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination (160% ~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
096 / 097
OUTDOOR UNITS _ MULTI V WATER IV _ SPECIFICATION
HP 20 16 18
Combination Unit ARWB200LAS4 ARWB160LAS4 ARWB180LAS4
Model Name ARWB080LAS4 ARWB100LAS4
Independent Unit ARWB200LAS4
ARWB080LAS4 ARWB080LAS4
kW 56.0 44.8 50.4
Cooling (Rated)
Capacity Btu/h 191,000 152,900 172,000
Heating (Rated) kW 63.0 50.4 56.7
Cooling (Rated) kW 11.20 7.72 8.95
Input
Heating (Rated) kW 11.67 8.40 9.54
EER 5.00 5.80 5.63
COP Rated Capacity 5.40 6.00 5.94
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 30.1 10.7 + 10.7 15.8 + 10.7
Rated Water Flow LPM 192 77 + 77 96 + 77
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 1 (Inverter) x 2 (Inverter) x 2
Motor Output x
Compressor W x No. 5,300 x 1 4,200 x 2 4,200 x 2
Number
Oil Type FVC68D(PVE) FVC68D(PVE) FVC68D(PVE)
Oil Charge cc 3,000 5,600 5,600
Liquid Pipe mm (inch) Ø12.7 (1/2) Ø12.7 (1/2) Ø12.7 (1/2)
Refrigerant
Low Pressure Gas Pipe mm (inch) Ø28.58 (1-1/8) Ø28.58 (1-1/8) Ø28.58 (1-1/8)
Connecting Pipes
High Pressure Gas Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
40A(PT 1-1/2) + 40A(PT 1-1/2) 40A(PT 1-1/2) + 40A(PT 1-1/2)
Inlet A (inch) 40A(PT 1-1/2) (Internal Thread)
(Internal Thread) (Internal Thread)
Water Connecting 40A(PT 1-1/2) + 40A(PT 1-1/2) 40A(PT 1-1/2) + 40A(PT 1-1/2)
Pipes Outlet A (inch) 40A(PT 1-1/2) (Internal Thread)
(Internal Thread) (Internal Thread)
Drain Outlet A (inch) 20A(PT 3/4) (External Thread) 20A(PT 3/4) (External Thread) 20A(PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 1 (755 x 997 x 500) x 2 (755 x 997 x 500) x 2
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 1 (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2
Net Weight kg x No. 140 x 1 127 x 2 127 x 2
Shipping Weight kg x No. 150 x 1 137 x 2 137 x 2
Sound Cooling dB(A) 54.0 50.0 52.0
Pressure Level Heating dB(A) 60.0 54.0 55.0
Sound Cooling dB(A) 66.0 62.0 64.0
Power Level Heating dB(A) 72.0 66.0 67.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 3.0 11.6 11.6
Refrigerant Factory
t-CO2eq 6.3 24.2 24.2
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 32(50) 26(40) 29(45)
Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination (160% ~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
MULTI V WATER IV HEAT RECOVERY
ARWB220LAS4 / ARWB240LAS4
ARWB280LAS4
HP 22 24 28
Combination Unit ARWB220LAS4 ARWB240LAS4 ARWB280LAS4
Model Name ARWB140LAS4 ARWB140LAS4 ARWB140LAS4
Independent Unit
ARWB080LAS4 ARWB100LAS4 ARWB140LAS4
kW 61.6 67.2 78.4
Cooling (Rated)
Capacity Btu/h 210,600 229,400 267,600
Heating (Rated) kW 69.3 75.6 88.2
Cooling (Rated) kW 11.70 12.93 15.68
Input
Heating (Rated) kW 12.37 13.51 16.34
EER 5.26 5.20 5.00
COP Rated Capacity 5.60 5.60 5.40
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 28.6 + 10.7 28.6 + 15.8 28.6 + 28.6
Rated Water Flow LPM 135 + 77 135 + 96 135 + 135
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 2 (Inverter) x 2 (Inverter) x 2
Motor Output x
Compressor W x No. 4,200 x 2 4,200 x 2 4,200 x 2
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 5,600 5,600 5,600
Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Refrigerant
Low Pressure Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8)
Connecting Pipes
High Pressure Gas Pipe mm (inch) Ø28.58 (1-1/8) Ø28.58 (1-1/8) Ø28.58 (1-1/8)
40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Inlet A (inch)
(Internal Thread) (Internal Thread) (Internal Thread)
Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Pipes Outlet A (inch)
(Internal Thread) (Internal Thread) (Internal Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 2 (755 x 997 x 500) x 2 (755 x 997 x 500) x 2
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2
Net Weight kg x No. 127 x 2 127 x 2 127 x 2
Shipping Weight kg x No. 137 x 2 137 x 2 137 x 2
Sound Cooling dB(A) 58.0 59.0 59.0
Pressure Level Heating dB(A) 58.0 58.0 58.0
Sound Cooling dB(A) 70.0 71.0 72.0
Power Level Heating dB(A) 70.0 70.0 71.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 11.6 11.6 11.6
Refrigerant Factory
t-CO2eq 24.2 24.2 24.2
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 35 (44) 39 (48) 45 (56)
Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination (160% ~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
098 / 099
OUTDOOR UNITS _ MULTI V WATER IV _ SPECIFICATION
HP 30 34 40
Combination Unit ARWB300LAS4 ARWB340LAS4 ARWB400LAS4
Model Name ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
Independent Unit
ARWB100LAS4 ARWB140LAS4 ARWB200LAS4
kW 84.0 95.2 112.0
Cooling (Rated)
Capacity Btu/h 286,700 324,900 382,200
Heating (Rated) kW 94.5 107.1 126.0
Cooling (Rated) kW 16.29 19.04 22.40
Input
Heating (Rated) kW 17.01 19.84 23.34
EER 5.16 5.00 5.00
COP Rated Capacity 5.56 5.40 5.40
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 30.1 + 15.8 30.1 + 28.6 30.1 + 30.1
Rated Water Flow LPM 192 + 96 192 + 135 192 + 192
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 2 (Inverter) x 2 (Inverter) x 2
Motor Output x
Compressor W x No. 5,300 x 1 + 4,200 x 1 5,300 x 1 + 4,200 x 1 5,300 x 2
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 5,800 5,800 6,000
Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Refrigerant
Low Pressure Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø41.3 (1-5/8)
Connecting Pipes
High Pressure Gas Pipe mm (inch) Ø28.58 (1-1/8) Ø28.58 (1-1/8) Ø34.9 (1-3/8)
40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Inlet A (inch)
(Internal Thread) (Internal Thread) (Internal Thread)
Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Pipes Outlet A (inch)
(Internal Thread) (Internal Thread) (Internal Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 2 (755 x 997 x 500) x 2 (755 x 997 x 500) x 2
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2
Net Weight kg x No. (140 x 1) + (127 x 1) (140 x 1) + (127 x 1) 140 x 2
Shipping Weight kg x No. (150 x 1) + (137 x 1) (150 x 1) + (137 x 1) 150 x 2
Sound Cooling dB(A) 55.0 59.0 55.0
Pressure Level Heating dB(A) 61.0 61.0 61.0
Sound Cooling dB(A) 67.0 72.0 68.0
Power Level Heating dB(A) 73.0 74.0 74.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 8.8 8.8 6.0
Refrigerant Factory
t-CO2eq 18.4 18.4 12.5
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 49 (60) 55 (64) 64
Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination (160% ~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
MULTI V WATER IV HEAT RECOVERY
ARWB420LAS4 / ARWB440LAS4
ARWB480LAS4
HP 42 44 48
Combination Unit ARWB420LAS4 ARWB440LAS4 ARWB480LAS4
Model Name ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
Independent Unit ARWB140LAS4 ARWB140LAS4 ARWB140LAS4
ARWB080LAS4 ARWB100LAS4 ARWB140LAS4
kW 117.6 123.2 134.4
Cooling (Rated)
Capacity Btu/h 401,700 420,800 459,000
Heating (Rated) kW 132.3 138.6 151.2
Cooling (Rated) kW 22.9 24.13 26.88
Input
Heating (Rated) kW 24.04 25.18 28.01
EER 5.14 5.11 5.00
COP Rated Capacity 5.50 5.50 5.40
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 30.1 + 28.6 + 10.7 30.1 + 28.6 + 15.8 30.1 + 28.6 + 28.6
Rated Water Flow LPM 192 + 135 + 77 192 + 135 + 96 192 + 135 + 135
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 3 (Inverter) x 3 (Inverter) x 3
Motor Output x
Compressor W x No. 5,300 x 1 + 4,200 x 2 5,300 x 1 + 4,200 x 2 5,300 x 1 + 4,200 x 2
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 8,600 8,600 8,600
Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Refrigerant
Low Pressure Gas Pipe mm (inch) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8)
Connecting Pipes
High Pressure Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8)
40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) +
Inlet A (inch)
40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread)
Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) +
Pipes Outlet A (inch)
40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 3 (755 x 997 x 500) x 3 (755 x 997 x 500) x 3
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3
Net Weight kg x No. (140 x 1) + (127 x 2) (140 x 1) + (127 x 2) (140 x 1) + (127 x 2)
Shipping Weight kg x No. (150 x 1) + (137 x 2) (150 x 1) + (137 x 2) (150 x 1) + (137 x 2)
Sound Cooling dB(A) 60.0 60.0 60.0
Pressure Level Heating dB(A) 62.0 62.0 62.0
Sound Cooling dB(A) 72.0 72.0 74.0
Power Level Heating dB(A) 74.0 74.0 76.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 14.6 14.6 14.6
Refrigerant Factory
t-CO2eq 30.5 30.5 30.5
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 64 64 64
Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination (160% ~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
100 / 101
OUTDOOR UNITS _ MULTI V WATER IV _ SPECIFICATION
HP 50 54 60
Combination Unit ARWB500LAS4 ARWB540LAS4 ARWB600LAS4
Model Name ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
Independent Unit ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
ARWB100LAS4 ARWB140LAS4 ARWB200LAS4
kW 140.0 151.2 168.0
Cooling (Rated)
Capacity Btu/h 478,100 516,000 573,300
Heating (Rated) kW 157.5 170.1 189.0
Cooling (Rated) kW 27.49 30.24 33.60
Input
Heating (Rated) kW 28.68 31.51 35.01
EER 5.09 5.00 5.00
COP Rated Capacity 5.49 5.40 5.40
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 30.1 + 30.1 + 15.8 30.1 + 28.6 + 28.6 30.1 + 30.1 + 30.1
Rated Water Flow LPM 192 + 192 + 96 192 + 192 + 135 192 + 192+ 192
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 3 (Inverter) x 3 (Inverter) x 3
Motor Output x
Compressor W x No. 5,300 x 2 + 4,200 x 1 5,300 x 2 + 4,200 x 1 5,300 x 3
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 8,800 8,800 9,000
Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Refrigerant
Low Pressure Gas Pipe mm (inch) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8)
Connecting Pipes
High Pressure Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8)
40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) +
Inlet A (inch)
40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread)
Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 1-1/2) +
Pipes Outlet A (inch)
40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 3 (755 x 997 x 500) x 3 (755 x 997 x 500) x 3
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3
Net Weight kg x No. (140 x 2) + (127 x 1) (140 x 2) + (127 x 1) 140 x 3
Shipping Weight kg x No. (150 x 2) + (137 x 1) (150 x 2) + (137 x 1) 150 x 3
Sound Cooling dB(A) 58.0 60.0 56.0
Pressure Level Heating dB(A) 63.0 62.0 62.0
Sound Cooling dB(A) 70.0 74.0 70.0
Power Level Heating dB(A) 75.0 76.0 76.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 11.8 11.8 9.0
Refrigerant Factory
t-CO2eq 24.6 24.6 18.8
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 64 64 64
Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination (160% ~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
MULTI V WATER IV HEAT RECOVERY
ARWB620LAS4 / ARWB640LAS4
ARWB680LAS4
HP 62 64 68
Combination Unit ARWB620LAS4 ARWB640LAS4 ARWB680LAS4
ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
Model Name ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
Independent Unit
ARWB140LAS4 ARWB140LAS4 ARWB140LAS4
ARWB080LAS4 ARWB100LAS4 ARWB140LAS4
kW 173.6 179.2 190.4
Cooling (Rated)
Capacity Btu/h 592,700 611,600 649,800
Heating (Rated) kW 195.3 201.6 214.2
Cooling (Rated) kW 34.10 35.33 38.08
Input
Heating (Rated) kW 35.71 36.85 39.68
EER 5.09 5.07 5.00
COP Rated Capacity 5.47 5.47 5.40
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 30.1 + 30.1 + 28.6 + 10.7 30.1 + 30.1 + 28.6 + 15.8 30.1 + 30.1 + 28.6 + 28.6
Rated Water Flow LPM 192 + 192 + 135 + 77 192 + 192 + 135 + 96 192 + 192 + 135 + 135
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 4 (Inverter) x 4 (Inverter) x 4
Motor Output x
Compressor W x No. 5,300 x 2 + 4,200 x 2 5,300 x 2 + 4,200 x 2 5,300 x 2 + 4,200 x 2
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 11,600 11,600 11,600
Liquid Pipe mm (inch) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8)
Refrigerant
Low Pressure Gas Pipe mm (inch) Ø44.5 (1-3/4) Ø44.5 (1-3/4) Ø53.98 (2-1/8)
Connecting Pipes
High Pressure Gas Pipe mm (inch) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø44.5 (1-3/4)
40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Inlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40
(Internal Thread) (Internal Thread) (Internal Thread)
Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Pipes Outlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40
(Internal Thread) (Internal Thread) (Internal Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 4 (755 x 997 x 500) x 4 (755 x 997 x 500) x 4
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4
Net Weight kg x No. (140 x 2) + (127 x 2) (140 x 2) + (127 x 2) (140 x 2) + (127 x 2)
Shipping Weight kg x No. (150 x 2) + (137 x 2) (150 x 2) + (137 x 2) (150 x 2) + (137 x 2)
Sound Cooling dB(A) 61.0 61.0 61.0
Pressure Level Heating dB(A) 64.0 64.0 63.0
Sound Cooling dB(A) 73.0 73.0 75.0
Power Level Heating dB(A) 76.0 76.0 77.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 17.6 17.6 17.6
Refrigerant Factory
t-CO2eq 36.7 36.7 36.7
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 64 64 64
Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination (160% ~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
102 / 103
OUTDOOR UNITS _ MULTI V WATER IV _ SPECIFICATION
HP 70 74 80
Combination Unit ARWB700LAS4 ARWB740LAS4 ARWB800LAS4
ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
Model Name ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
Independent Unit
ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
ARWB100LAS4 ARWB140LAS4 ARWB200LAS4
kW 196.0 207.2 224.0
Cooling (Rated)
Capacity Btu/h 668,900 707,100 764,400
Heating (Rated) kW 220.5 233.1 252.0
Cooling (Rated) kW 38.69 41.44 44.80
Input
Heating (Rated) kW 40.35 43.18 46.68
EER 5.07 5.00 5.00
COP Rated Capacity 5.46 5.40 5.40
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 30.1 + 30.1 + 30.1 + 15.8 30.1 + 30.1 + 30.1 + 28.6 30.1 + 30.1 + 30.1 + 30.1
Rated Water Flow LPM 192 + 192 + 192 + 96 192 + 192 + 192 + 135 192 + 192 + 192 + 192
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 4 (Inverter) x 4 (Inverter) x 4
Motor Output x
Compressor W x No. 5,300 x 3 + 4,200 x 1 5,300 x 3 + 4,200 x 1 5,300 x 4
Number
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 11,800 11,800 12,000
Liquid Pipe mm (inch) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8)
Refrigerant
Low Pressure Gas Pipe mm (inch) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8)
Connecting Pipes
High Pressure Gas Pipe mm (inch) Ø44.5 (1-3/4) Ø44.5 (1-3/4) Ø44.5 (1-3/4)
40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Inlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40
(Internal Thread) (Internal Thread) (Internal Thread)
Water Connecting 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Pipes Outlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40
(Internal Thread) (Internal Thread) (Internal Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 4 (755 x 997 x 500) x 4 (755 x 997 x 500) x 4
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4
Net Weight kg x No. (140 x 3) + (127 x 1) (140 x 3) + (127 x 1) 140 x 4
Shipping Weight kg x No. (150 x 3) + (137 x 1) (150 x 3) + (137 x 1) 150 x 4
Sound Cooling dB(A) 59.0 61.0 57.0
Pressure Level Heating dB(A) 65.0 63.0 63.0
Sound Cooling dB(A) 71.0 75.0 71.0
Power Level Heating dB(A) 77.0 77.0 77.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 14.8 14.8 12.0
Refrigerant Factory
t-CO2eq 30.9 30.9 25.1
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 64 64 64
Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected. The numbers in parentheses means maximum connectable indoor units in accordance
with outdoor units combination (160% ~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms
by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
NOTE
104 / 105
NOTE
NOTE
106 / 107
NOTE
NOTE
108 / 109
2021
LG Electronics Distributed by
http://www.lg.com
http://partner.lge.com