Catalogue - Multi - V - 5 - CDU LG

The document provides information about LG's MULTI V outdoor units. It discusses the history and evolution of the MULTI V brand since 2006, highlighting technological innovations over different generations. These include inverter technology, oil return features, vapor injection, and more efficient compressors. The latest MULTI V 5 model from 2017 is described as having an ultimate inverter compressor, biomimetic fan design, dual sensing control, and high efficiency.

Uploaded by

Phuc Hoang
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
71 views110 pages

Catalogue - Multi - V - 5 - CDU LG

The document provides information about LG's MULTI V outdoor units. It discusses the history and evolution of the MULTI V brand since 2006, highlighting technological innovations over different generations. These include inverter technology, oil return features, vapor injection, and more efficient compressors. The latest MULTI V 5 model from 2017 is described as having an ultimate inverter compressor, biomimetic fan design, dual sensing control, and high efficiency.

Uploaded by

Phuc Hoang
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 110

2021

CATALOUGE
2021 OUTDOOR UNITS
028 - 103
OUTDOOR
UNITS
MULTI V 5 (Heat Recovery) 038

MULTI V 5 (Heat Pump) 054

MULTI V S (Cooling Only / 070


Heat Pump / Heat Recovery)

MULTI V WATER IV 082


(Heat Pump / Heat Recovery)

002 / 003
WHY LG MULTI V

MULTI V BRAND HISTORY

2017 ~

· Dual Sensing Control


2013 · Ultimate Inverter Compressor
· One Unified Platform Heat
pump & Heat recovery
· Active Refrigerant Control
2010 · Ocean Black Fin
· Variable Heat Exchanger
Circuit
· Smart Load Control
· High Pressure Oil Return
· Smart Oil Return
2008 · Vapor Injection
· Vapor Injection (Advanced)
· Continuous Heating

· Ø7.0 Wide louver


2006 · LGDC Inverter

· Heat Recovery
· Ø7.0 Corrugate
· Fuzzy Algorithm
· AC Inverter
· R410A

Since the time when LG launched Korea’s first residential air conditioner in water flow control technology.
1968, the company has worked to continuously enhance its technological
innovation and reliability. As a result of sustained improvement, LG VRF In 2017, the ultimate VRF solution was introduced with MULTI V 5. This generation
launched the first generation of MULTI V in 2006 and achieved significant has fully improved its technological potential with the powerful and reliable
development. With the best-in-class compressor technology and innovation yet economical Ultimate Inverter Compressor, effective corrosion resistance
applied to every part and control solution, MULTI V has evolved to be on of with the Ocean Black Fin coating and enlarged fans. Dual Sensing Control
the world’s most efficient and reliable VRF solutions. offers the most pleasant indoor environment while minimizing unnecessary
energy loss by sensing both temperature and humidity to efficiently
The first and second generations of MULTI V boasted inverter technology and non- manage cooling, heating and part load.
ozone depleting technology, while MULTI V III was produced with cutting edge
tech like oil return with HiPORTM and double compression features with mid- MULTI V 5 has been designed for the ultimate efficiency, performance,
pressure refrigerant allowed by Vapor Injection. The innovative technologies flexibility, comfort and control, ensuring the most pleasant indoor
of MULTI V’s fourth generation brought about product leadership in experience.
efficiency. Its Smart Load Control adjusts with the outdoor temperature,
while optimizing refrigeration management and heat exchange for both
cooling and heating.

MULTI V’s wide range of VRF solutions satisfies various building types
and sizes. MULTI V S’s size discharge was designed for small to mid-sized
buildings while MULTI V Water is a water-cooled VRF solution with variable
2017
· High Efficiency
· Ultimate Inverter Compressor
· Large Capacity ODU with Biomimetics
Technology Fan
· Dual Sensing Control
· Ocean Black Fin

2006 2008 2010 2013

· Ø7.0 Corrugate · Heat Recovery · High Pressure Oil Return · Active Refrigerant Control
· Fuzzy Algorithm · Ø7.0 Wide louver · Vapor Injection · Variable Heat Exchanger Circuit
· AC Inverter · Fuzzy Algorithm · Continuous Heating · Smart Load Control
· R410A · LGDC Inverter · Smart Oil Return
· Vapor Injection (Advanced)

004 / 005
HIGH EFFICIENCY
With various industry-leading technologies, such as Ultimate Inverter Compressor and Dual Sensing Control, LG MULTI V 5
offers the world class high efficiency. These advanced technologies help MULTI V 5 to achieve the lowest energy
consumption while preserving the environment.

Efficiency comparison Previous Model


006 / 007
ULTIMATE INVERTER
COMPRESSOR
As the core technology of the air conditioning system, the Ultimate Inverter Compressor of MULTI V 5 boasts its
ultimate efficiency and durability, designed based on the unique technology and innovation of LG HVAC.

All Inverter
Provide high efficiency with low vibration and low noise

Six By-pass Valves


Prevent compressor damage due to excessively
compressed refrigerant more efficiently than 4 by-pass valves

01. Vapor Injection


Maximize heating capacity via two-stage compression

02. Enhanced Bearing with PEEK Material


Newly invented system motivated by PEEK (Polyetheretherketone)
bearing used for aero engine to increase operation range and durability

03. Wide Operation Range from 10 to 165Hz


Improved part load efficiency at all operation ranges

04. HiPORTM (High Pressure Oil Return)


Resolve compressor efficiency loss caused by oil return

05. Smart Oil Management


Oil level detection in real time
008 / 009
LARGE CAPACITY ODU
WITH BIOMIMETICS
TECHNOLOGY FAN

Humpback Whale Design Clam Shell Pattern Increased Air Flow Rate
Inspired by the bumps on the humpback Like the clam shell textures, the range With extended shroud, discharged air current
whale’s flipper, the tubercles on the back side difference created by moire pattern reduced is stabilized and power consumption is
increased wind power by reducing flacking. noise level. reduced.
*Based on 290 m3/min

As a result of the biomimetics technology invented through years of joint study with Department of Mechanical and
Aerospace Engineering of Seoul National University, the fan of MULTI V 5 increased wind capacity while it reduced its
power consumption when operating.

Large Capacity Outdoor Unit


Enhanced core parts like biomimetics technology-based fans, 4-sided heat exchanger as opposed to 3-sided heat
exchanger of previous model and compressor with increased efficiency and capacity allow large capacity for outdoor
units. A single unit of MULTI V 5 can provide up to 26HP.

010 / 011
DUAL SENSING
CONTROL
The cooling load is mainly based on the amount of both sensible heat load and latent heat load. Most importantly, the
cooling load is keen to, and thus, greatly affected by external humidity, rather than the outdoor temperature. For such
reason, Dual Sensing Control of MULTI V 5 senses both temperature and humidity and applies sensed data for load
control in order to obtain in-depth understanding of sensible heat load and latent heat load. This helps preventing
excessive cooling load supply and eventually offers the most pleasant and comfortable cooling environment the users
want with reduction in energy consumption.

Previous VRF
[Single Sensing] [Dual Sensing]

Smart Load Control (SLC)


Optimizes energy efficiency for
maximized indoor comfort level

Seasonal
Efficiency
DID YOU KNOW Up to 18%
THAT VRF UNTIL NOW (vs. standard mode
HAS ONLY SENSED at 26HP)
SINGLE INFORMATION?
Comfort Cooling
Mild cooling operation without stopping
in between for maximized user comfort

Improved
Indoor Comfort
OCEAN BLACK FIN
HEAT EXCHANGER
LG’s exclusive “Ocean Black Fin” heat exchanger is specially designed for durable and long-lasting performance even
in corrosive environments. The black coating is applied for protection from various corrosive external conditions and
the hydrophilic film keeps water from accumulating on the heat exchanger’s fin, minimizing moisture buildup. This
improvement in durability prolongs the product’s lifespan and lowers both the operational and maintenance costs.

* Test Method B Simulation Validated


(Test condition: Salt contaminated condition + severe
industrial/traffic environment (NO2/SO2))

* Based on 1,500 UL test hours

012 / 013
ADVANTAGES
10 OF MULTI V

1 ULTIMATE
EFFICIENCY 3 SUPERIOR
DURABILITY 4 DESIGN
FLEXIBILITY
Ultimate Energy Saving with LG’s exclusive “Black Fin” Flexible Installation with
Dual Sensing Control. heat exchanger is designed Large Capacity Outdoor Unit.
to perform even in corrosive
MULTI V 5 enables easy type change-
Environments.
over to suit the purpose of any building.

Hydrophilic film

Acryl + Epoxy +
Melamine resin

Humidity Temperature Aluminum fin

2
Certified protection

INNOVATIVE
TECHNOLOGIES
MULTI V 5
- Ultimate Inverter Compressor ※ Verification of corrosion resistance performance
- Declared by TUV Rheinland
- Biomimetics Technology Fan - Test Method B of ISO21207
- Test condition : Salt contaminated condition
+ severe industrial/traffic environment

Scroll Compressor
SMART BUSINESS
5 CONTROLS 6 SUPPORT
MULTI V responds to diverse building - Engineering Tools & Support
environments with LG ThinQ-based - LG Air Conditioning Academy
AI control and individual/central - Asia Regional HQ
integrated control solutions.

7 DIVERSE
PRODUCT 9 10
LINE UP MADE IN BRAND
LG offers a specialized product lineup
KOREA RELIABILITY
suitedforvariousbusinessenvironments,
perfectly responding to the unique LG MULTI V line-up emphasizing high Global production sites facilitate world-
conditions no matter the use case. quality and durability with Korea made class customer service.
products.

8 DIVERSE
INTEGRATED
SOLUTION
Integrated solution optimized for
various business environments,
including hot water, AHU, BMS, and
EMS.

014 / 015
WHY LG MULTI V

ENGINEERING TOOLS & SUPPORT


From planning to service & maintenance and then to de-construction, an architectural project goes through many stages from the beginning to the end of
its lifecycle. Along those stages, various engineering tools are applied to solve the diverse issues happening in each stage, with the most optimal solution
possible. Given the usage of such tools, buildings are effectively designed, built, supervised, and maintained throughout their lifecycle.
DedicatedtoprovidethebestHVACengineeringsupport,LGElectronicsAirSolutionBusinessUnitoffersseveralengineeringtoolsandsolutionsfocused
on HVAC, during the overall lifecycle of a building, related to the three categories. Among them, the LATS* Program series has been developed to offer
the best tool for LG HVAC systems, providing our customers with a solution that allows for faster, easier and more accurate model selection, draft energy
estimations and more.

* LATS : LG Air-conditioner Technical Solution

I II III
Energy Estimation Model Selection Installation
& Energy Modeling & Design Environment
Simulation

01 Planning

LATS
Energy

02 Schematic Design

LATS
HVAC

03 Design Development
Energy
Modeling LATS CAD
- eQUEST � LATS REVIT
- TRNSYS

CFD
04 Construction Design - FLUENT

05 Construction

06 Service & Maintenance LGMV


01 Draft Energy Estimation
LATS Energy
LATS Energy is a program developed by LG to estimate energy consumption and analyze the life
cycle cost of LG commercial air conditioning systems during a project's early stages.

02 Building Energy Modeling


eQuest, EnergyPro, Trace700 and More
ThesearecertifiedcommercialprogramswhichassesstheHVACsystemefficiencyandbuilding’s
annual energy savings for building standards or certifications, like LEED. LG HQ supports these
programs for the project stages of Design Development and Construction Design where in the
overall designing is finished.

03 Model Selection
LATS HVAC
LATSHVACisamodelselectionprogramthataccuratelyandquicklyselectsthemostsuitableLG
commercial air conditioning systems for each design.
In addition to model selection, faster estimation on refrigerant piping diameter and additional
refrigerant is possible, along with auto printing of reports.

04 Design
LATS CAD
LATS CAD enables faster and more accurate 2D design of LG commercial air conditioning
systems.It also enables modules for quotation and installation review that minimize inherent
problems during installation and commissioning.
※ AutoCAD program is required.

LATS REVIT
LATS REVIT allows BIM users to have an attractive 3D design of LG commercial airconditioning
systems with embedded calculations for refrigerant and efficiency features.
※ AutoCAD Revit program is required.

05 Environment Simulation
CFD Analysis
CFDAnalysisisappliedinareasofestimating:indoorairflowandtemperaturedistributionwhile
operating VRF products, outdoor airflow distribution, and noise level. By running a simulation
beforeconstruction,engineersestimatepossibleissuesandfindoptimalsolutionsformalfunctions
that could occur after construction.

06 Service & Maintenance


LGMV
LGMV offers real-time MULTI V cycle monitoring. During start-up, LGMV can check for normal
operation as well as troubleshoot any errors. Also it helps to find causes of errors and solve the
problem faster.

016 / 017
WHY LG MULTI V

BENEFITS OF LG MULTI V

Benefits for
Building Owners
Efficient Management & Cost Reduction
- Fault Detection Diagnosis enables easy maintenance
- Requires no extra manpower for regular maintenance
- Withdiversecontrolsystems,maintenancecostisminimized

Reliability at Every Stage


- UltimateInverterCompressordevelopedandmanufactured
in Korea
- Corrosion resistant Ocean Black Fin for harsh conditions
operation
- Smart Oil management (Auto Oil Balancing and Active Oil
return) decreases compressor damage

Customized Comfort and Solution


- Compatible option between Heat pump and Heat recovery
system is possible

Benefits for
Developers & Construction Companies

Green Solutions
- Optimized for LEED/BREEAM certification
- Renewable energy solution provided through geothermal
application

Maximizing Space Utilization


- Large capacity in compact size enhances space utilization

Smart Building Solutions


- Seamless integration with current Building Management
Systems
- Wi-Fi control available for anytime, anywhere access (via the
'LG ThinQ' mobile app)
- Energy management and control according to usage and
planning is possible with LG’s centralized control solution
Benefits for
Consultants
Versatile Solutions
- Air-cooled, Water-cooled, Heating, and Air Handing Unit
interlocking solutions

Professional Design Support


- LATS(LGAir-conditionerTechnicalSolution)fordraftenergy
estimation, model selection, HVAC design and 3D designing
- CFD Analysis to ensure suitable solutions and prevent
malfunctions
- Energy simulation offered to find the optimal solution

Optimized Convenience with HVAC Design


- Flexible and longer piping length facilitates HVAC
designing process
- Meets any type of customer requirements of diverse
environment, design conditions, and building applications

Benefits for
End-users

Cost Saving Operation


- High efficiency guaranteed throughout product line-up
- Up to 31% cost savings with MULTI V's Smart Load Control*

Comfort Cooling & Heating


- Smart Load Control maximizes indoor comfort level
- DualSensingControlofferspleasantandcomfortablecooling
and heating environment
- Duration time of Continuous Heating is 11% longer than
previous model**

Convenient Functions
- Low-noise operation provides a pleasant environment

* Dual Smart Load Control ESEER based, below 50% humidity, model ARUM260LTE5
** LG internal test result

018 / 019
WHY LG MULTI V

APPLICATION SOLUTIONS

Office
Supporting efficiency with flexibility

High Rise Office Building Small to Medium sized Office Building

• MULTI V WATER IV • High Static Duct • Variable water flow


• MULTI V 5 / S • 4 Way CST** • PDI
• DX AHU • PDI* control kit

The MULTI V series revitalizes the workspace by providing fresh air at all times. LG's intelligent control solutions add comfort to any space.

Commercial
Maximizing business, minimizing cost

Shopping Mall Retail Quick Service Restaurant (QSR)

• MULTI V • Convertible • MULTI V • HYDRO KIT


• MULTI V 5 • DX AHU
• ERV • ERV • 4 Way CST

The highly efficient, energy saving MULTI V 5 and MULTI V reduces operation costs, and provides comfort that suits any purpose and any space, helping
to invest the extra space and expense to your business.

* PDI : Power Distribution Indicator ** CST : Cassette


Residential
Creating a comfortable home

Condominium Apartments

• MULTI V 5 HR • Low static duct


• MULTI V 5 • 1 Way CST • PDI
• HYDRO KIT • 3rd party controller RTU gateway

MULTI V 5 HR/HP with variousIDU enables optimal solution, providing comfort to every space through individual zone control and hot water solution.

Hospitality
Meeting diverse needs

• MULTI V 5 • DX AHU • HYDRO KIT • Low Static Duct • Remote control • Refrigerant leak detector

The diverse applications that can be applied to MULTI V 5 helps bring just the right solution to a sophisticated hotel business.

020 / 021
WHY LG MULTI V

DIVERSE INTEGRATED SOLUTION


Hot Water Solution Refrigerant Leak Detection Solution
Water heating costs can be reduced with a heat pump, which provides higher efficiency Real-time refrigerant leak detection ensures a safe environment.
than a boiler system. The HYDRO KIT can be connected to MULTI V 5, providing When refrigerant concentration exceeds 6,000ppm for 5 seconds, the indoor unit
temperatures up to 80°C. Energy savings can be maximized with the combination of will stop operation and alert users with a buzzer or light switch (Dry contact option).
the HYDRO KIT and the MULTI V 5 Heat Recovery system.

ROOM
Indoor Unit
Buzzer Alarm
Card Key
MULTI V 5
Outdoor Unit
Cooling I/O Module

HR Unit
Ball Valve
(Field supply)
MULTI V 5
Outdoor Unit
Refrigerant Remote
Detector Controller

� Regulation : EN378, BREEAM, ASHRAE Std. 15 & 34

HYDRO KIT Heating Hot Water

Power Consumption Distribution Solution


Air Handling Unit (AHU) Solution In case of shared power consumption in a building, a solution to distribute the power
consumption amount per tenant might be necessary. Electricity charges can be billed
AHU is a suitable solution for cooling and heating in large space. With an LG AHU to each tenant by using output from the LG Power Distributor Indicator (PDI). An
Comm. Kit (for both return air / supply air control) connected to the DX coil of the AHU, administrator is able to check the power usage for each space and date as needed.
LG VRF system can be applied to deliver conditioned air. If the PDI is used in conjunction with an LG central controller, the results can be
exported to Excel.

MULTI V 5 B Office
Outdoor Unit 20 kWh
WHM C Office
(Watt Meter)
Pulse Signal 30 kWh D Office
A Office
20 kWh
30 kWh

Power PDI
100 kWh

Total Control of Any Device


EEV Signal In order to manage multiple spaces and multiple buildings,
the administrators should be able to control systems from wherever they are. The LG
Communication central controller can be controlled from any web browser that supports HTML5. Now
Kit Indoor Unit through the implementation of HTML5, the interface will look great and perform well
EEV Kit
on any device.

Ref. pipe (Liquid)


Ref. pipe (Gas)
Communication

AHU

Management office Library Main administration building


PC Tablet Mobile
DIVERSE INTEGRATED SOLUTION
Energy Management Solution Interlocking Solution
Since HVAC systems use a significant portion of any building’s total amount of energy, by Using ACU Module
the energy saving functions of a controller can make a big difference. The energy
It is costly to introduce a BMS system to control multiple devices or systems in a
navigation function enables you to set target values for energy consumption over a
small building. With the ACU module, various IO contact points (DI, DO, UI, AO) can be
certain period of time. In addition, to achieve that value, the administrator can set the
interlocked and integrated, while control is possible from the LG central controller. This
energy saving logic in 7 steps and predict the expected usage relative to the target value.
enables an efficient management of lighting, pumps and other devices in the building in
Active self-management enables energy savings through out the building.
conjunction with the HVAC system.

Saving Engineering Cost


Pump Lighting Fan Sensor
70% Strengthen
Maintenance Efficiency
Compressor Capacity IDU Operation IDU Operation
Control Ratio Control Level
ACS IO Module

Target
AC Smart (ACP)
Forecasting

Interlocking Solution Using Dry Contact


3rd party thermostats can be used to control LG air conditioners in a room by using a
multi point dry contact. The dry contact enables basic
control of air conditioners as well as making it possible to report the status and any
errors impacting the indoor unit.
Integration Solution with BMS The Standard III remote control has a DO port. With this DO port, it is possible to
There are many BMS protocols used for the control of buildings’ various systems such interlock the indoor unit with 3rd party devices such as lighting, a fan, or a radiator, based
as HVAC, lighting, power and security. LG has a wide range of gateway products for on things like operation mode or current temperature.
different protocols such as BACnet, Modbus, and LonWorks. In addition, LG gateways The indoor unit can be interlocked with various types of input such as card key-tag,
include Stand-alone door sensor, human detection sensor etc. so that the air
central control capability to act as a back-up controller of the BMS if needed. conditioner is automatically operated. In addition, the dry contact option settings enable
operation of air conditioner to maintain proper temperature when the occupant is
absent. This solution makes sure that the room does not overheat or become too cold
Small - Medium size building Medium - Large size building when unoccupied so that energy cost can be saved.

IDU ~64 : ACP LonWorks

IDU ~128 : AC Smart 5


IDU 16~64 : Modbus RTU
(BACnet IP/Modbus TCP)

IDU ~256 : ACP 5


(BACnet IP/Modbus TCP)

BMS Protocol
BMS System

022 / 023
LINE-UP

OUTDOOR UNITS LINE-UP


Features Appearance 8 10 12 14 16 18 20 22 24 26 28 30 32

● ● ●

● ● ● ● ● ● ●
HEAT RECOVERY
• Dual Sensing Control
• Large capacity ODU (Up to 26HP)
• Continuous Heating ● ● ● ● ● ●
• Black Fin heat exchanger
• Heat pump or heat recovery function
• Flexible installation with
heat recovery unit and large capacity
• For large space, high rise building and
individual control building

● ● ●

● ● ● ● ● ● ●

HEAT PUMP
● ●
• Dual Sensing Control
• Large capacity ODU (Up to 32HP)
• Continuous Heating
• Black Fin heat exchanger ● ● ● ● ● ●
• Heat pump function
• For large space, high rise building and
individual control building
Unit : HP / ● 380V, 3Ø

34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 .... 104

● ● ● ● ● ● ● ●

● ● ● ● ● ● ● ● ● ● ● ●

● ● ● ● ● ● ● ● ● ● ● ●

● ● ● ● ● ● ● ●

● ● ● ● ● ● ● ● ● ● ● ●

● ● ● ● ● ● ● ● ● ● ● ●

024 / 025
LINE-UP

OUTDOOR UNITS LINE-UP


Features Appearance 3 4 5 6 8 10 12 14 16 18 20

○ ○ ○ ○

• Space saving
• Flexible design applications ○● ○●
- Slim, light, and broad range (4 - 12 HP)
- Large number of connectable indoor units
(Up to 20 Units)
• For small / medium building

● ● ●


HEAT RECOVERY

● ● ● ●

● ●
HEAT PUMP / HEAT RECOVERY
• High efficiency system regardless external conditions
• Indoor installation
• Low noise operation (No fan)
• For water-sourced system, high rise building and building with
aesthetic requirements.
• Simultaneous cooling and heating
• Minimized energy cost by water sourced
heat recovery system
• For individual control building
Unit : HP / ○ 220V, 1Ø / ● 380V, 3Ø

22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 .... 96

● ● ● ● ● ●

● ● ● ● ● ●

● ● ● ● ● ●

026 / 027
OUTDOOR
UNITS

MULTI V 5 (HEAT RECOVERY)


MULTI V 5 (HEAT PUMP)
MUTLI V S (COOLING ONLY / HEAT PUMP / HEAT RECOVERY)
MULTI V WATER IV ( HEAT PUMP / HEAT RECOVERY)
028 / 029
OUTDOOR UNITS _ MULTI V 5 _ KEY FEATURES

INNOVATIVE TECHNOLOGIES
Dual Sensing Smart Load Control (SLC) Energy Savings with Dual Sensing Control (Tempera-
Enhanced energy saving & increased indoor comfort ture & Humidity)
Cooling loads vary according to both temperature and humidity. Case study
With Dual Sensing SLC, work exerted to meet the load depends on both
Weather characteristics of Warsaw, Poland
temperature and humidity. As a result, less capacity will be required in lower humidity
The portion of cooling operation hours at low humidity condition (Below 50% RH) is big. The
conditions.
cooling load of this condition is less than the load at standard (50 ~ 70% RH) or high (over
It influences the VRF system main processor’s decision on where to set the system’s 70% RH) humidity condition even in the same outdoor air temperature. MULTI V 5 raises
target high or low system pressure values. the evaporating Temp up at low load (Low humidity) condition to enable energy saving and
prevent over-cooling which can happen when the system is controlled only by using outdoor
air Temp.
Smart Load Control responds to :
1) Outdoor ambient dry bulb temperature
Warsaw weather in Summer
2) Outdoor ambient relative humidity (when enabled)
90%
Cooling Indoor Units - adjusts target low pressure
80% High Humidity
Raises the target low pressure value as cooling load falls and/or ambient temperature falls. Lowers the target 70% ~ 100%
low pressure value as cooling load rises and/or ambient temperature rises.
70%

Relative Humidity
Heating Indoor Units - adjusts target high pressure 60%
Mid Humidity Dual
SLC Sensing
Lowers the target high pressure as heating load falls and/or ambient temperature rises. 50% ~ 70%
SLC
Raises the target high pressure as heating load rises and/or ambient temperature falls. 50%
Low Humidity
40% 0% ~ 50%
What are the benefits?
30%
Enhanced energy savings 20%
- Cooling Mode 23°C 25°C 27°C 29°C 31°C 33°C 35°C
Source : Outdoor Air Temperature
By raising the target low pressure during off-peak cooling operation, the compressor lift is https://energyplus.net/weather
reduced. This slows compressor’s speed which leads to a decrease in compressor’s power
Time Portion of Relative Humidity in Summer
consumption. (Warsaw, Poland)
- Heating Mode RH (%) Portion
By lowering the target high pressure during off-peak heating operation, the compressor lift
70% ~ 100% 8%
is reduced. This slows compressor’s speed which leads to a decrease in compressor’s power
50% ~ 70% 45%
consumption.
0% ~ 50% 47%
Increased indoor comfort
Smart Load Control uses one (or two) sensors to measure changing outdoor weather
conditions and prepares the VRF system for operation under the revised weather conditions
before changing conditions impact indoor comfort.
Energy Consumption in Cooling Season
When we compared the energy consumption between SLC (Outdoor air Temp sensing only)
and Dual sensing SLC (Outdoor air Temp and humidity sensing), Dual sensing SLC control can
Cooling load according to Cooling load according to
temperature change humidity change save 6% more energy compared to SLC. So dual sensing control is more efficient than SLC.
Cooling Load

Cooling Load

EER
MULTI V 5 SLC
MULTI V 5 Dual Sensing SLC 9.4 9.4
9.2
9.0
8.1 8.6
25°C 30°C 35°C Temperature 40% 60% 80% Relative 7.9
Humidity
Latent heat load Sensible heat load
6.9 6.9
※ Constant indoor temp condition 6.0

Cooling Load
Previous Cooling Capacity

For low temperature, lower Adjusting capacity


to meet load
load and
Actually 31°C ~ 29 ~ 31°C 27 ~ 29°C 25 ~ 27°C 23 ~ 25°C
capacity are required External Load
Required
Cooling
Outdoor Air Temperature
Internal Load
Capacity
※ This energy simulation was performed in LG internally based on 16HP model.
Temperature & Humidity
Evaporation Temperature
Low Humidity
Power Consumption in Cooling Season
SLC
Yearly Power Input (kWh) - ODU
Lower load and
OAT MV4 (Fixed) MV5 SLC MV5 Dual SLC
capacity need High Humidity
higher evaporation 31 ~ 17 15 13
Outdoor
temperature Standard Temperature (°C) 29 ~ 31 91 73 62
(Non SLC)
Low Temperature High Temperature 27 ~ 29 183 136 124

Efficiency 25 ~ 27 243 170 165


Low Humidity
23 ~ 25 155 110 109
SLC
Total 690 (137%) 503 (100%) 474 (94%)
Higherevaporationtempera-
High Humidity
ture results 6% more energy saving
Standard compared to SLC
in higher efficiency (Non SLC) Outdoor
Temperature (°C)
Low Temperature High Temperature
INNOVATIVE TECHNOLOGIES
Comfort Cooling Intelligent Defrost
Increased indoor comfort & enhanced operating efficiency Increased heating run-hours
First reference use Indoor Unit (IDU) is operating in a season when its load is less MULTI V has provided an intelligent defrost algorithm and settings based on
than the design load, the comfort cooling algorithm controls the indoor unit’s coil current outdoor ambient temperature. With the addition of the outdoor air
superheat, thus raising the discharged air temperature as the space temperature humidity sensor, MULTI V 5 Intelligent Defrost just got smarter.
is approaching set point. MULTI V 5’s comfort control algorithm monitors the MULTI V 5 computes the current ambient air dew point temperature - the
outdoor air temperature and humidity conditions. When changing weather temperature at which frost will form on the outdoor unit coil in during winter
conditions are deteriorating and there is a high potential the indoor unit’s load operation. MULTI V 5 makes continuous adjustments to the refrigeration cycle's
will remain stable or may increase, comfort cooling delays or abandons raising the operating parameters to keep the outdoor coil surface temperature above actual
target superheat as the room temperature approaches set-point. When changing dew point which can be calculated by using dry bulb Temp and relative humidity.
weather conditions are favorable to raising target superheat, target superheat is When the refrigeration cycle's operating parameters can be adjusted no further
moderated. without sacrificing heating comfort, further adjustment is stopped and frost is
allowed to build on the coil, therefore activating defrost.

What are the benefits?


Increased indoor comfort
If comfort cooling is turned off, and the temperature of the leaving air is not raised, when the What are the benefits?
fan speed is reduced to low speed, there is a potential that occupants located directly under a
The Intelligent Defrost algorithm increases the VRF system’s heating run-hours and reduces the
cassette IDU or supply air registers could feel cold air falling on them resulting in a lower overall
number of defrost cycles required to maintain optimum heating performance irrelevant of the
comfort experience.
mode and method of defrost selected.
With comfort cooling turned on, the discharged air temperature is controlled. When the IDU
controller reduces the fan speed, the potential for cold air falling on occupants located under the
cassette IDU or supply air registers is reduced.

Enhanced operating efficiency


Raising superheat reduces refrigerant volume flowing through the coil.
As flow decreases, demand on the compressor decreases and the compressor speed will be Conventional
reduced, thus saving energy. Defrost

Previous Model Frost


accumulation begins
Coil
Surface (°C)

Comfort &
Repeated on & off
Continuous Cooling
Dew Frost accumulation
Point (°C)

Cooling Mode Fan Mode Cooling Mode

※ Indoor unit set up available with Standard III Remote Controller.

Preventing cold draft & repeated turn On / Off


Improved Indoor Comfort

Indoor temp
LG Intelligent Defrost /
Smart Heating
Frost
Not cool accumulation begins
zone Coil
Surface (°C)

Dew
Point (°C)
Comfort
zone Set
temperature Additional Time
Spent Heating

Too cool
zone ※ Increased heating operation time per day : Up to 17%
• LG Internal Test result,
• Test condition (MULTI V 5 vs MULTI V IV, 22HP)
Previous Model Time - Outdoor : 2/1°C, Indoor : 20/15°C
- Humidity : 83%, Dew Point : -0.5°C

030 / 031
OUTDOOR UNITS _ MULTI V 5 _ KEY FEATURES

INNOVATIVE TECHNOLOGIES
Variable Path Heat Exchanger Active Refrigerant Control
Optimized system efficiency & continuous heating Stable operation & sustaining most efficient operation
MULTI V 5 outdoor units (ODU) are manufactured with horizontally split ODU coil The accumulator in the outdoor unit has a storage tank mounted inside known
consisting of two independent circuit sections. as the receiver tank. The receiver tank is equipped with inlet and outlet valves
Each half of the coil is independently controlled. that are electronically opened and closed. Refrigerant is being passed between
This split coil feature makes it possible for MULTI V 5 to provide continuous the accumulator and the receiver tank on a continuous basis. MULTI V 5 active
heating during defrost. The split coil and valve arrangement also makes it possible refrigerant control algorithm goal is to minimize the amount of refrigerant
for the MULTI V 5 to change the flow path of refrigerant through one of the two in circulation. The lower the volume in circulation the lower the cost to move
coils only, or through both coils in either a series or parallel arrangement. it around the system and the higher the stability of the refrigeration cycle. It
Based on system pressures, ambient temperature conditions, and mode of accomplishes this by constantly monitoring the system operating pressures and
operation, the system controller may modify the selected path at any time. temperatures and a variety of other vital control metrics of the refrigeration cycle.
When the cycle is out of balance, an adjustment in the amount of circulating
refrigerant occurs.

What are the benefits?


Optimizes system efficiency regardless of operating modes as ambient weather conditions
change. What are the benefits?
Customizes the used area of the outdoor unit’s heat exchange surface.
Widens the ambient temperature range at which stable operation occurs.
Low ambient cooling and / or light building load Sustains most efficient system operation regardless of outdoor weather conditions, operating
mode, or building load.
• Half active
• Lower idle
Cooling Heating Part Load

Amount of refrigerant in
Full load cooling receiver
• Upper & lower active
• Series circuited
• High velocity refrigerant flow

Heating - all conditions


• Upper & Lower active
• Parallel circuited
• Low velocity refrigerant flow

Efficiency

Heating

Cooling Non-receiver tank


Fixed refrigerant amount Control optimized Refrigerant amount
Maximized efficiency
Series Half Active Parallel
Efficiency
Continuous Heating
Fixed refrigerant type
Heating performance

Heating
efficiency 3%
Part load
Heating supply
efficiency 10%
On On

Effect of partial defrost

Cooling
efficiency
Time Active Refrigerant Control
Non-Partial defrost Refrigerant quantity (kg)
INNOVATIVE TECHNOLOGIES
HiPORTM Sub-cooling & Vapor Injection
Advanced compressor reliability & efficiency Increased heating performance
HiPOR™ is an LG trademark that stands for High Pressure Oil Return. It consists of an MULTI V 5 is equipped with advanced sub-cooler and vapor injection control
oil separator, oil drain line between the separator and the compressor. HiPOR™ technology system. The sub-cooler algorithm sub-cools liquid refrigerant just enough so that
enables oil to return directly into the compressor, instead of returning through the it can travel to the farthest IDU in the system operating in cooling mode without
refrigerant suction pipe. changing state. During low ambient operation down to -25°C (Heating mode),
This prevents energy waste when oil flows between the separator and the compressor. the sub-cooler provides medium temperature refrigerant gas to the compressor’s
Because the operating pressure in the chamber containing the oil sump of the vapor injection system. When injected into the compression chamber, system mass
compressor and the pressure in the oil separator are nearly equal, there is no loss in flow increases which stabilizes the system’s suction pressure. In all cases the vapor
compressor efficiency. injection increases the compressors cycle efficiency and reduces operating cost.

What are the benefits?


Maximizes reliability and efficiency of the compressor.
Non HiPOR™ HiPOR™ What are the benefits?
1 Refrigerant
Compressor Provides stable refrigeration cycle operation over a wide range of outdoor ambient operating
3 conditions.
4
Increases compressor efficiency when compared to systems without vapor injection technology.
Efficiency Increase
Up to 33%
2

Oil Technology Mechanism


5

Non HiPOR™ HiPOR™ High-pressure


Low pressure High pressure Oil Low pressure High pressure Oil Low-pressure
refrigerant Compressor refrigerant Separator refrigerant Compressor refrigerant Separator
1 2 3 4 1 2 3 4

5 Energy loss in suction gas No energy loss in suction gas 5

• LG Internal Test result,


• Test condition - 15Hz Rating Condition : TC = 37.9°C, Te : 7.2°C

Mid-pressure
Smart Oil Management (Vapor injection port)
Energy saving, enhanced heating & increased compressor reliability
MULTI V 5 performs oil return when needed under normal operating conditions. An
IDU (Heating)
oil level sensor is provided in every LG VRF compressor. If the sensor indicates the
compressor oil level is low, the main system processor is notified that an oil return cycle is
necessary. Oil balancing cycle occurs every hour and does not hinder system performance.
EEV
It balances the oil level deposit between both compressors in multi-compressor frames.
Older VRF technology protects compressors from oil loss based on timed oil return logic High temp
discharge
because there was no way to know if the oil level in any one compressor was low. LG’s
unique oil level measuring sensor actively monitors the oil level in each compressor.
MID-stage Injection
SC
HEX
Low temp
What are the benefits? suction

Energy savings : fewer oil return cycles eliminate unnecessary energy consumption.
Increases system heating run-time during winter operation.
Increases compressor reliability.
ODU Coil

Heating Performance Smart Oil Return


Performance Comparison
Heating performance
Heating Heating Heating

Oil Oil
Non heating Non heating Non-Vapor Injection
Time
27%
Timed oil return logic (Non-oil Sensor) Oil Level Sensor Oil

Increased heating operation time per day Auto Oil Balancing Up to


: Up to 12% -25°C
• LG Internal Test result,
• Test condition
- without oil level sensor : -25 -20 -15 -10 -5 0 7 11 15

every 8 hour oil recovery operation Oil Outdoor temp(°C)


- with oil level sensor : ※ Improved heating performance by 27%.
non oil recovery operation
Oil Level Sensor
※ Comparison tested on 10HP model.

032 / 033
OUTDOOR UNITS _ MULTI V 5 _ KEY FEATURES

INNOVATIVE TECHNOLOGIES
Corrosion Resistance Black Fin Biomimetic Fan
Improved durability Maximized performance
The black coating with enhanced epoxy resin is applied on the heat exchanger The fans in MULTI V 5's outdoor unit have been upgraded to feature a moire pattern
for strong protection from various corrosive external conditions such as salt similar to that of a clam shell's exterior that help with noise reduction. At the same time,
contamination and air pollution. unlike the fans installed in previous products that generate separation of flow due to
Moreover, the hydrophilic film keeps water from accumulating on the heat absence of tubercles, the bumpy back design inspired by the bumps on the humpback
exchanger’s fin, minimizing moisture buildup and eventually making it even more whale’s flipper is applied as the tubercles on the back side of the fans, increasing wind
corrosion resistant. power by reducing flacking. In addition to the biomimetic technology-based fans,
LG Corrosion Resistance solution passed ISO 21207 accelerated corrosion test extended shroud of MULTI V 5 allows more high static pressure and helps fans to blow
conducted by an independent test organization and the result has been certified higher air volume for efficient operation. With wider air guide, discharged air current is
by prestigious global certification organization, TUV. stabilized and noise level is reduced.

What are the benefits?


This improvement in durability prolongs the product’s lifespan and lowers both the operational What are the benefits?
and maintenance costs. Based on the biomimetic technology, the fans of MULTI V 5 increased air flow rate by 10% in
comparison to previous model and reduced its power consumption up to 20% when compared
with the fan blade design on
MULTI V IV. This eventually results in maximized performance with large capacity.

※ Verification of corrosion resistance performance


- Declared by TUV Rheinland
Humpback
- Test Method B of ISO21207
Whale Design
- Test condition : Salt contaminated condition
+ severe industrial/traffic environment(NO2 / SO2)
Clam Shell
Pattern

Hydrophilic film (Water flow)


The Hydrophilic coating minimizes moisture
buildup on the fin.
Acryl + Epoxy + Melamine resin
(Corrosion resistant)
The Black coating provides strong protection
from corrosion.
Aluminum fin

SST (Salt Spray Test)


Test Process Test Result
(5% Area of defects compared to initial)

1,950 hr
Process
1,000 hr
Fog1)
repeated
95%
(35°C, 24hr)

Test process is conducted according to ISO 9227. Gold Fin Black Fin
1) Salty water concentration : NaCl aqueous solution (5%) 100% copper material to prevent Air flow rate Power consumption
corrosion & refrigerant leakage
3
m /min W

CCT (Cyclic Corrosion Test)


Test Process Test Result
(5% Area of defects compared to initial) 320 1,500
20%
1,300 hr
10%
290
500 hr
Fog1) Wet2) 1,200
(35°C, 2hr)
Dry
(70°C, 2hr) (50°C, 2hr)
160%

Process Gold Fin Black Fin

repeated 100% copper material to prevent


corrosion & refrigerant leakage
※ Test process is conducted according to ISO 14933.
1) Salty water concentration : NaCl aqueous solution (5%)
Previous Model Previous Fan Design
※ Dry condition changed : 60°C, 4hr → 70°C, 2hr
2) Deionized water
※ Comparison based on 20HP model ※ Comparison based on air volume of 290m3/min
DESIGN FLEXIBILITY
One Unified Model Flexible Installation with
Heat pump / Heat recovery with one platform Large Capacity Outdoor Units
LG MULTI V 5 satisfies users’ various needs with just one platform. Heat Pump System More flexible design potential & space saving
works for the sites where either cooling or heating operation is needed, while Heat
Large capacity outdoor units of MULTI V 5 minimize installation space that spares
Recovery System fits perfectly to the sites wherein both the cooling and heating
valuable floor space and significantly decreases total installed weight. This gives
operations are simultaneously needed or locations installed with Hot Water Solution to
users more flexible design potential and better use of the saved space.
provide hot water and heating via radiators.

12.25m2

What are the benefits?


Previous Model
MULTI V 5 allows the building previously installed with Heat Pump system to switch to the Heat
23%
Recovery system (by adding HR boxes and a third pipe) for changing purpose of the building or 9.42m2 Reduction
remodeling reasons via simple piping construction.

Heat Pump System


23% 15%
Reduction Reduction

12.25m2 9.42m2 3,640kg 3,100kg

Previous Model Previous Model

Foot print area Product weight

※ Comparison basis : 1 Rows of outdoor units 728kW (72.8kW x 10sets) installation case

Slave 1
Outdoor unit
Master
Outdoor unit
Wider Operation Range
2 pipes Able to operate at extreme conditions

Liquid Pipe
With improved inverter cooling technology, sub-cooling and vapor injection, MULTI V
Gas Pipe 5 offers an extended range of heating and cooling operations. It can perform normal
heating operations at temperatures as low as -25°C. Cooling operations function at
Indoor unit
temperatures as low as -15°C or as high as 48°C making it an adequate solution for
specialized areas like technical rooms. Moreover, MULTI V 5’s cycle technology with
Changeover
Type

enhanced durability enables optimal cooling performance at high temperature that


increases up to 48°C.

Heat Recovery System Outdoor air temp (°C WB)

18°C
15°C

-20°C

-25°C
10°C 15°C 20°C 27°C

Heating Indoor air temp(°C DB)


Heat Recovery Unit

Outdoor air temp (°C DB)

Slave 1 Master 48°C


Outdoor unit Outdoor unit
3 pipes 43°C

Previous Model

Indoor unit -10°C

Liquid Pipe -15°C


High Pressure Gas Pipe 10°C 14°C 25°C 27°C
Low Pressure Gas Pipe Cooling Indoor air temp (°C WB)
HR unit

034 / 035
OUTDOOR UNITS _ MULTI V 5 _ KEY FEATURES

USER-FRIENDLY CONTROL
Low-Noise Operation Simple Test Run via LGMV
For noise sensitive environment Increased overall efficiency in installation
Unlike the previous model which enables Low-Noise Operation only during To make sure that the product functions properly, conducting a test run is recommended.
night after judgment time, the Low-Noise Operation of MULTI V 5 can function For previous product, professional engineer who is well-aware of more than 40 different
regardless of the time at the noise sensitive areas. When used, the speed of the functional settings and more than 200 error codes had to check main parts in order to
outdoor unit fans is restricted during normal operation. make sure that the test run had succeeded. With Mobile LGMV of MULTI V 5, fast and
accurate auto test run can be executed and the professional installer running the test
can receive test results via email, which shortens installation hours and increases overall
Previous Model efficiency in installation processes.

Previous

Load

Sound level Off

(Judgment time) Low-noise operation time

On

6:00 12:00 13:00 18:00 21:00 0:00 6:00


Highest Start End
outdoor temp

Load

Sound level Scheduled setting available

Low-noise Low-noise
operation operation Wi-Fi MV Module
On Off On

6:00 12:00 18:00 6:00


Start End Start End

Indoor setting available

Cycle Monitoring Diagnosis Installation Smart Management

LGMV
Multi V 5 Outdoor Units

10. Sound
OUTDOOR Levels
UNITS _ MULTI V 5 _ TECHNICAL DATA

10.1 Sound Pressure Level


Multi
MultiVV
55 Outdoor
Outdoor
Units
Units
Position of Sound Pressure Level Measuring Cooling / Heating Operation
9.9.Operation
OperationLimits
Limits
Note
Cooling
Cooling
Cooling / Heating
/ Heating
Operation
Operation Heating
• Data is valid at free field condition
• Data
50°C is valid at nominal operating 20°Ccondition
48°C 18°C
• Sound
45°C level will vary depending on 15°C a range of
factors
40°C such as the construction(acoustic

Outdoor Temperature (°C WB)


1m

Outdoor Temperature (°C DB)


absorption
35°C
coefficient) of particular
10°C room in

Range for warming up operation


Range for continuous operation

Range for continuous operation


which the equipment is installed

Range for pull down operation


30°C 5°C
1m
• Sound
25°C
level can be increased in static
pressure
20°C
mode or used air guide.0°C
• Data is valid at free field condition.
15°C -5°C
• Data is valid at nominal operating condition.
• Sound level will vary depending on a range of factors such as the construction
10°C Unit:dB(A)
-10°C
Mocoeffi
(Acoustic absorption delcient) of particular room in which the equipmentCisooling 5°C
Heating
-15°C
installed. ARUM080LTE5 58.0 0°C
59.0
• Sound level can be increased in static pressure mode or used air guide.
ARUM100LTE5 58.0 59.0 -20°C
-5°C

-10°C
ARUM120LTE5 59.0 60.0 -25°C
-15°C
ARUM140LTE5 60.0 10°C 14°C 15°C 20°C 25°C 27°C 30°C61.0 10°C 15°C 20°C 25°C 27°C 30°C
Outdoor Units Function
ARUM160LTE5 60.5 Indoor Temperature (°C WB) 61.5 Indoor Temperature (°C DB)
Category Functions MULTI V 5 Note
Note
ARUM180LTE5 61.0 1. 1.
TheseThese figures
figures
assume
assume thethe following
followingoperating
operating6conditions:
2.0
conditions:
Variable Path of Outdoor Unit HEX ○ Note
ARUM20HiPOR 0LTE TM 5
(High Pressure Oil Return) ○
62.0 Equivalent
Equivalent
Level
piping
piping
difference:0m
difference:0m
length:7.5m
length:7.5m
1. These figures assume the following operating conditions
Level
6 4.5 :
Equivalent piping length : 7.5m
ARUM22Humidity
Key Refrigerant 0LTE5Sensor ○ 64.5 2. 2.
RangeRange of pull
of pull
down
Level difference : 0m
downoperation:
operation: 65.5
Components If the
If the
relative
relativehumidity
humidity is too
is toohigh,
high,
cooling
cooling
capacity
capacity
cancan
be be
decreased
decreased by by
thethe
sensible
sensible
heat
heat
reduction.
reduction.
2. Range of pull down operation :
ARUM24Corrosion 0LTE5Resistance Black Fin ○ 65.0
If the relative humidity is too high, cooling capacity 67can .0be decreased by the sensible heat reduction.
ARUM26Oil 0LSensor
TE5+ Advanced PCB Cooling ○
65.0 67.0
3. Warming up operation means that the outdoor unit operates to reach the range of continuous operating,
however it may not operate continuously due to safety or protection logic.
Dual Sensing ○
ARUM22Low 1LTNoise
E5Operation ○
61.5 62.5
ARUM24High 1LTStatic
E5Mode of Outdoor Unit Fan ○ 62.0 63.0
ARUM26Partial 1LTEDefrosting
5 ○ 62.5 63.5
Multi
Multi V 5V 5 Outdoor Units
ARUM28Auto 0L T E
Dust5Removal of Outdoor Unit ○ 62.8 63.8 Outdoor Units

Useful Function (Fan reverse rotation) 9. Operation


Simultaneous
9. Operation Limits Limits
Cooling / Heating Operation
ARUM30Indoor 0LTECooling
5 Comfort Mode Based 63.1 64.1
○ Simultaneous Cooling / Heating Operation
ARUM32Outdoor 0LTE5 Temperature
63.8 Cooling
Simultaneous Cooling / Heating
65.8Heating
Operation
Smart Load Control (SLC)
ARUM34(Changing 0LTE5indoordischargeairtemperature ○ 65.6 30°C
66.6 20°C
according to load)
ARUM360LTE5 66.0 67.8
Outdoor Unit Control Refer to Humidity ○ 25°C
ARUM38Defrost 0LTE/5Deicing ○
66.2 68.0 16°C 675675
Outdoor Temperature (°C WB)

15°C
Outdoor Temperature (°C DB)

ARUM40High 0LTPressure
E5 Switch ○ 66.3 20°C 68.1
Range for continuous operation

Range for pull down operation

ARUM42Phase 0LTE 5
Protection ○ 66.5 68.2 10°C
Range for warming up operation

Range for continuous operation


15°C
Reliability
ARUM44Restart 0LTEDelay 5 (3-minutes) ○
66.8 68.9
Self Diagnosis ○ 10°C
ARUM46Soft 0LTStart
E5 ○
67.8 69.3 5°C

ARUM48Test 0LTRun E5Function ○ 68.0


5°C
70.0
ARUM50AC 0LEzTE 5 Controller)
(Simple 67.0
PQCSZ250S0 0°C 68.6 0°C

ARUM52AC 0LEzTE 5
Touch PACEZA00067.1 -5°C 68.7
Central Controller AC Smart 5 PACS5A000
ARUM540LTE5 67.2 68.8 -5°C
ACP (Advanced Control Platform) 5 PACP5A000 -10°C
ARUM56AC 0LManager
TE5 5 PACM5A00067.4 69.5
A R U
BNU (Building NetworkM 5 8ACPT
0 L E5
Lonworks PLNWKB00068.3 -15°C
10°C 14°C 15°C 20°C
69.8 -10°C
25°C 27°C 30°C
Unit) ARUM600LTE5 ACP BACnet 68.5
PQNFB17C0 70.4 10°C 15°C 20°C 25°C 27°C 30°C

Refrigerant Charging Kit PRAC1


Installation ARUM620LTE5 68.6 70.5
Indoor Temperature (°C WB) Indoor Temperature (°C DB)
Note
Note
Variable Water Flow Valve Control Kit -
ARUM64Standard 0LTE5 PPWRDB000
68.7 1. 1.
TheseThese figures
figures
Equivalent
Note
assume
assume
piping
thethe following
following
length:7.5m
operating
operating 7conditions:
0.6
conditions:
PDI (Power Distribution Equivalent piping length:7.5m
Indicator) ARUM66Premium 0LTE5 PQNUD1S4068.8 1. Level
Level These difference:0m
figures assume the following operating conditions
difference:0m 70.6 :
2. 2.
Range
Equivalent
Range piping
of pull
of pull down
down
length : 7.5m
operation:
operation:
Cool / Heat A RUM680LTE5
Selector PRDSBM69.0 IfLevel
If the the difference
relative
relative humidity
: 0mis too
humidity is too high,
high, cooling
cooling 7can
1.can
capacity
capacity 1be be decreased
decreased by the
by the sensible
sensible heatheat reduction.
reduction.
2. Range of pull down operation :
Low Ambient AKit
RUM700LTE5 PRVC269.6 7 1 . 3
If the relative humidity is too high, cooling capacity can be decreased by the sensible heat reduction.
IO Module (ODU Dry Contact) PVDSMN000
ARUM720LTE5 69.8 71.8
LGMV PRCTIL0
ARU
Cycle Monitoring M74Mobile
Device 0LTELGMV 5 PLGMVW10069.1 70.9
ARUM760LTE5 69.2 70.9

677

※ ○ : Applied, - : Not Applied

676676

036 / 037
HEAT RECOVERY
- Air cooled VRF Heat Pump & Heat Recovery
- 22.4kW ~ 268.8kW (Cooling capacity based)
- 3Ø, 380 ~ 415V, 50Hz
- Top discharge outdoor unit
- Ability to function as Heat Pump or Heat Recovery

TOTAL PIPING LENGTH

Designed
Design
For
For
The Ultimate
The Ultimate
1,000m 225m
TOTAL PIPING LENGTH Longest Piping Length

Piping capabilities

between ODU ~ IDU


Height Difference
Total Piping Length 1,000m

110m
Actual longest piping length (Equivalent) 200m (225m)
Longest piping length after 1st branch (conditional application) 40m (90m)
Height between ODU ~ IDU 110m
Height between IDU ~ IDU 40m
Height between ODU ~ ODU 5m

between IDU ~ IDU


Height Difference
40m
How does it work?
Dual Sensing

Energy savings

Partial Defrost

Reliability

Interchangeable between
heat pump and heat recovery
Low noise

Type
Changeover

Advanced performance

038 / 039
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION

MULTI V 5 HEAT RECOVERY


ARUM080LTE5 / ARUM100LTE5
ARUM120LTE5 / ARUM140LTE5

HP 8 10 12 14
Combination Unit ARUM080LTE5 ARUM100LTE5 ARUM120LTE5 ARUM140LTE5
Model Name
Independent Unit ARUM080LTE5 ARUM100LTE5 ARUM120LTE5 ARUM140LTE5
Cooling (Rated) kW 22.4 28.0 33.6 39.2
Btu/h 76,400 95,000 114,600 133,800
Heating (Rated) kW 22.4 28.0 33.6 39.2
Capacity
Btu/h 76,400 95,000 114,600 133,800
Heating (Max) kW 25.2 31.5 37.8 44.1
Btu/h 86,000 107,500 129,000 150,500
Cooling (Rated) kW 5.28 6.83 7.71 8.67
Input Heating (Rated) kW 3.97 4.92 6.85 8.13
Heating (Max) kW 4.78 5.92 8.26 9.72
COP Cooling (Rated) 4.24 4.10 4.36 4.52
Heating (Rated) 5.64 5.69 4.91 4.82
COP
Heating (Max) 5.27 5.32 4.58 4.54
SCOP 4.69 4.51 5.01 4.63
Exterior Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 1 (Inverter) x 1 (Inverter) x 1 (Inverter) x 1
Compressor Motor Output x Number W x No. 4,200 x 1 5,300 x 1 5,300 x 1 5,300 x 1
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 3,900 3,900 3,900 3,900
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W x No. 1,200 x 1 1,200 x 1 1,200 x 1 900 x 2
Fan Air Flow Rate (High) m3/min x No. 240 x 1 240 x 1 240 x 1 320 x 1
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP

Pipe Liquid Pipe mm (inch) Ø9.52 (3/8) Ø9.52 (3/8) Ø12.7 (1/2) Ø12.7 (1/2)
Connections for Low Pressure Gas Pipe mm (inch) Ø19.05 (3/4) Ø22.2 (7/8) Ø28.58 (1-1/8) Ø28.58 (1-1/8)
Heat Recovery High Pressure Gas Pipe mm (inch) Ø15.88 (5/8) Ø19.05 (3/4) Ø19.05 (3/4) Ø22.2 (7/8)
Pipe Connections Liquid Pipe mm (inch) Ø9.52 (3/8) Ø9.52 (3/8) Ø12.7 (1/2) Ø12.7 (1/2)
for Heat Pump Gas Pipe mm (inch) Ø19.05 (3/4) Ø22.2 (7/8) Ø28.58 (1-1/8) Ø28.58 (1-1/8)
Dimensions (W x H x D) mm x No. (930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x1
Dimensions (W x H x D) - Shipping mm x No. (960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1 (1,280 x 1,825 x 796) x 1
Net Weight kg x No. 198 x 1 215 x 1 215 x 1 237 x 1
Shipping Weight kg x No. 208 x 1 225 x 1 225 x 1 250 x 1
Sound Pressure Cooling dB(A) 58.0 58.0 59.0 60.0
Level Heating dB(A) 59.0 59.0 60.0 61.0
Sound Cooling dB(A) 84.0 85.0 86.0 89.0
Power Level Heating dB(A) 87.0 88.0 89.0 93.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A R410A
Precharged Amount
kg 7.5 9.5 9.5 13.5
Refrigerant in Factory
t-CO2eq 15.7 19.8 19.8 28.2
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 13 (20) 16 (25) 20 (30) 23 (35)

1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected.The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160%
~ 200%). The recommended ratio is 130%.
MULTI V 5 HEAT RECOVERY
ARUM160LTE5 / ARUM180LTE5
ARUM200LTE5 / ARUM220LTE5

HP 16 18 20 22
Combination Unit ARUM160LTE5 ARUM180LTE5 ARUM200LTE5 ARUM220LTE5
Model Name
Independent Unit ARUM160LTE5 ARUM180LTE5 ARUM200LTE5 ARUM220LTE5
Cooling (Rated) kW 44.8 50.4 56.0 61.6
Btu/h 152,900 172,000 191,000 210,200
Heating (Rated) kW 44.8 50.4 56.0 61.6
Capacity
Btu/h 152,900 172,000 191,000 210,200
Heating (Max) kW 50.4 56.7 63.0 69.3
Btu/h 172,000 193,000 215,000 236,500
Cooling (Rated) kW 10.90 11.03 12.76 15.92
Input Heating (Rated) kW 10.28 10.12 12.20 14.15
Heating (Max) kW 12.39 11.94 14.69 16.76
COP Cooling (Rated) 4.11 4.57 4.39 3.87
Heating (Rated) 4.36 4.98 4.59 4.35
COP
Heating (Max) 4.07 4.75 4.29 4.13
SCOP 4.83 4.0 3.98 3.9
Exterior Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 1 (Inverter) x 2 (Inverter) x 2 (Inverter) x 2
Compressor Motor Output x Number W x No. 5,300 x 1 (5,300 x 1) + (4,200 x 1) (5,300 x 1) + (4,200 x 1) (5,300 x 1) + (4,200 x 1)
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 3,900 5,200 5,200 5,200
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W x No. 900 x 2 900 x 2 900 x 2 900 x 2
Fan Air Flow Rate (High) m3/min x No. 320 x 1 320 x 1 320 x 1 320 x 1
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP

Pipe Connections Liquid Pipe mm (inch) Ø12.7 (1/2) Ø15.88 (5/8) Ø15.88 (5/8) Ø15.88 (5/8)
for Heat Low Pressure Gas Pipe mm (inch) Ø28.58 (1-1/8) Ø28.58 (1-1/8) Ø28.58 (1-1/8) Ø28.58 (1-1/8)
Recovery High Pressure Gas Pipe mm (inch) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8) Ø28.58 (1-1/8)
Pipe Connections Liquid Pipe mm (inch) Ø12.7 (1/2) Ø15.88 (5/8) Ø15.88 (5/8) Ø15.88 (5/8)
for Heat Pump Gas Pipe mm (inch) Ø28.58 (1-1/8) Ø28.58 (1-1/8) Ø28.58 (1-1/8) Ø28.58 (1-1/8)
Dimensions (W x H x D) mm x No. (1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1
Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 1 (1,280 x 1,825 x 796) x 1 (1,280 x 1,825 x 796) x 1 (1,280 x 1,825 x 796) x 1
Net Weight kg x No. 237 x 1 300 x 1 300 x 1 300 x 1
Shipping Weight kg x No. 250 x 1 312 x 1 312 x 1 312 x 1
Sound Pressure Cooling dB(A) 60.5 61.0 62.0 64.5
Level Heating dB(A) 61.5 62.0 64.5 65.5
Sound Cooling dB(A) 90.0 92.0 93.0 93.0
Power Level Heating dB(A) 94.0 95.0 96.0 97.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A R410A
Precharged Amount
kg 13.5 16.0 16.0 16.0
Refrigerant in Factory
t-CO2eq 28.2 33.4 33.4 33.4
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 26 (40) 29 (45) 32 (50) 35 (56)

1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected.The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160%
~ 200%). The recommended ratio is 130%.

040 / 041
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION

MULTI V 5 HEAT RECOVERY


ARUM240LTE5 / ARUM260LTE5
ARUM221LTE5 / ARUM241LTE5

HP 24 26 22' 24'
Combination Unit ARUM240LTE5 ARUM260LTE5 ARUM221LTE5 ARUM241LTE5
Model Name ARUM120LTE5 ARUM120LTE5
Independent Unit ARUM240LTE5 ARUM260LTE5
ARUM100LTE5 ARUM120LTE5
Cooling (Rated) kW 67.2 72.8 61.6 67.2
Btu/h 229,300 248,400 210,200 229,300
Heating (Rated) kW 67.2 67.2 61.6 67.2
Capacity
Btu/h 229,300 248,400 210,200 229,300
Heating (Max) kW 74.3 74.3 69.3 75.6
Btu/ 253,400 253,400 236,500 257,900
Cooling (Rated) kW 17.41 20.20 14.54 15.41
Input Heating (Rated) kW 15.89 15.99 11.77 13.70
Heating (Max) kW 18.80 19.15 14.18 16.52
COP Cooling (Rated) 3.86 3.60 4.24 4.36
Heating (Rated) 4.23 4.20 5.23 4.91
COP
Heating (Max) 3.95 3.88 4.89 4.58
SCOP 4.34 4.34 - -
Exterior Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 2 (Inverter) x 2 (Inverter) x 2 (Inverter) x 2
Compressor Motor Output x Number W x No. 5,300 x 2 5,300 x 2 5,300 x 2 5,300 x 2
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 5,200 5,200 7,800 7,800
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W x No. 900 x 2 900 x 2 (1,200 x 1) + (1,200 x 1) (1,200 x 1) + (1,200 x 1)
Fan Air Flow Rate (High) m3/min x No. 320 x 1 320 x 1 (240 x 1) + (240 x 1) (240 x 1) + (240 x 1)
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP

Pipe Connections Liquid Pipe mm (inch) Ø15.88 (5/8) Ø19.05 (3/4) Ø15.88 (5/8) Ø15.88 (5/8)
for Heat Low Pressure Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø28.58 (1-1/8) Ø34.9 (1-3/8)
Recovery High Pressure Gas Pipe mm (inch) Ø28.58 (1-1/8) Ø28.58 (1-1/8) Ø28.58 (1-1/8)
Ø28.58 (1-1/8)
Pipe Connections Liquid Pipe mm (inch) Ø15.88 (5/8) Ø19.05 (3/4) Ø15.88 (5/8) Ø15.88 (5/8)
for Heat Pump Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø28.58 (1-1/8) Ø34.9 (1-3/8)
(930 x 1,690 x 760) x 1 + (930 x (930 x 1,690 x 760) x 1 + (930 x
Dimensions (W x H x D) mm x No. (1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1
1,690 x 760) x 1 1,690 x 760) x 1
(960 x 1,825 x 796) x 1 + (960 x (960 x 1,825 x 796) x 1 + (960 x
Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 1 (1,280 x 1,825 x 796) x 1
1,825 x 796) x 1 1,825 x 796) x 1
Net Weight kg x No. 310 x 1 310 x 1 (215 x 1) + (215 x 1) (215 x 1) + (215 x 1)
Shipping Weight kg x No. 320 x 1 320 x 1 (225 x 1) + (225 x 1) (225 x 1) + (225 x 1)
Sound Pressure Cooling dB(A) 65.0 65.0 61.5 62.0
Level Heating dB(A) 67.0 67.0 62.5 63.0
Sound Cooling dB(A) 95.0 95.0 88.5 89.0
Power Level Heating dB(A) 99.0 99.0 91.5 92.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A R410A
Precharged Amount
kg 17.0 17.0 19.0 19.0
Refrigerant in Factory
t-CO2eq 35.5 35.5 39.7 39.7
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 39 (61) 42 (64) 35 (44) 39 (48)

1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected.The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160%
~ 200%). The recommended ratio is 130%.
MULTI V 5 HEAT RECOVERY
ARUM261LTE5 / ARUM280LTE5
ARUM300LTE5 / ARUM320LTE5

HP 26' 28 30 32
Combination Unit ARUM261LTE5 ARUM280LTE5 ARUM300LTE5 ARUM320LTE5
Model Name ARUM140LTE5 ARUM160LTE5 ARUM180LTE5 ARUM200LTE5
Independent Unit
ARUM120LTE5 ARUM120LTE5 ARUM120LTE5 ARUM120LTE5
Cooling (Rated) kW 72.8 78.4 84.0 89.6
Btu/h 248,400 267,500 286,600 305,700
Heating (Rated) kW 72.8 78.4 84.0 89.6
Capacity
Btu/h 248,400 267,500 286,600 305,700
Heating (Max) kW 81.9 88.2 94.5 100.8
Btu/h 279,400 300,900 322,400 343,900
Cooling (Rated) kW 16.38 18.61 18.73 20.46
Input Heating (Rated) kW 14.98 17.13 16.97 19.05
Heating (Max) kW 17.98 20.65 20.20 22.95
COP Cooling (Rated) 4.44 4.21 4.48 4.38
Heating (Rated) 4.86 4.58 4.95 4.70
COP
Heating (Max) 4.56 4.27 4.68 4.39
SCOP - - - -
Exterior Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 2 (Inverter) x 2 (Inverter) x 3 (Inverter) x 3
Compressor Motor Output x Number W x No. 5,300 x 2 5,300 x 2 (5,300 x 2) + (4,200 x 1) (5,300 x 2) + (4,200 x 1)
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 7,800 7,800 9,100 9,100
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W x No. (900 x 2) + (1,200 x 1) (900 x 2) + (1,200 x 1) (900 x 2) + (1,200 x 1) (900 x 2) + (1,200 x 1)
Fan Air Flow Rate (High) m3/min x No. (320 x 1) + (240 x 1) (320 x 1) + (240 x 1) (320 x 1) + (240 x 1) (320 x 1) + (240 x 1)
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Pipe Connections
Low Pressure Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8)
for Heat Recovery
High Pressure Gas Pipe mm (inch) Ø28.58 (1-1/8) Ø28.58 (1-1/8) Ø28.58 (1-1/8) Ø28.58 (1-1/8)
Pipe Connections Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
for Heat Pump Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8)
(1,240 x 1,690 x 760) x 1 + (930 x (1,240 x 1,690 x 760) x 1 + (930 x (1,240 x 1,690 x 760) x 1 + (930 x (1,240 x 1,690 x 760) x 1 + (930 x
Dimensions (W x H x D) mm x No.
1,690 x 760) x 1 1,690 x 760) x 1 1,690 x 760) x 1 1,690 x 760) x 1
(1,280 x 1,825 x 796) x 1 + (960 x (1,280 x 1,825 x 796) x 1 + (960 x (1,280 x 1,825 x 796) x 1 + (960 x (1,280 x 1,825 x 796) x 1 + (960 x
Dimensions (W x H x D) - Shipping mm x No.
1,825 x 796) x 1 1,825 x 796) x 1 1,825 x 796) x 1 1,825 x 796) x 1
Net Weight kg x No. (237 x 1) + (215 x 1) (237 x 1) + (215 x 1) (300 x 1) + (215 x 1) (300 x 1) + (215 x 1)
Shipping Weight kg x No. (250 x 1) + (225 x 1) (250 x 1) + (225 x 1) (312 x 1) + (225 x 1) (312 x 1) + (225 x 1)
Sound Pressure Cooling dB(A) 62.5 62.8 63.1 63.8
Level Heating dB(A) 63.5 63.8 64.1 65.8
Sound Cooling dB(A) 90.8 91.5 93.0 93.8
Power Level Heating dB(A) 94.5 95.2 96.0 96.8
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A R410A
Precharged Amount
kg 23.0 23.0 25.5 25.5
Refrigerant in Factory
t-CO2eq 48.0 48.0 53.2 53.2
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 42 (52) 45 (56) 49 (60) 52 (64)

1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected.The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160%
~ 200%). The recommended ratio is 130%.

042 / 043
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION

MULTI V 5 HEAT RECOVERY


ARUM340LTE5 / ARUM360LTE5
ARUM380LTE5 / ARUM400LTE5

HP 34 36 38 40
Combination Unit ARUM340LTE5 ARUM360LTE5 ARUM380LTE5 ARUM400LTE5
Model Name ARUM220LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
Independent Unit
ARUM120LTE5 ARUM120LTE5 ARUM140LTE5 ARUM160LTE5
Cooling (Rated) kW 95.2 100.8 106.4 112.0
Btu/h 324,800 343,900 363,000 382,100
Heating (Rated) kW 95.2 100.8 106.4 112.0
Capacity
Btu/h 324,800 343,900 363,000 382,100
Heating (Max) kW 107.1 112.1 118.4 124.7
Btu/h 365,400 382,300 403,800 425,300
Cooling (Rated) kW 23.62 25.12 26.08 28.31
Input Heating (Rated) kW 21.00 22.74 24.02 26.17
Heating (Max) kW 25.02 27.06 28.52 31.19
COP Cooling (Rated) 4.03 4.01 4.08 3.96
Heating (Rated) 4.53 4.43 4.43 4.28
COP
Heating (Max) 4.28 4.14 4.15 4.00
SCOP - - - -
Exterior Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 3 (Inverter) x 3 (Inverter) x 3 (Inverter) x 3
Compressor Motor Output x Number W x No. (5,300 x 2) + (4,200 x 1) 5,300 x 3 5,300 x 3 5,300 x 3
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 9,100 9,100 9,100 9,100
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W x No. (900 x 2) + (1,200 x 1) (900 x 2) + (1,200 x 1) 900 x 4 900 x 4
Fan Air Flow Rate (High) m3/min x No. (320 x 1) + (240 x 1) (320 x 1) + (240 x 1) 320 x 2 320 x 2
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Pipe Connections
Low Pressure Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8)
for Heat Recovery
High Pressure Gas Pipe mm (inch) Ø28.58 (1-1/8) Ø28.58 (1-1/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8)
Pipe Connections Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
for Heat Pump Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8)
(1,240 x 1,690 x 760) x 1 + (930 x (1,240 x 1,690 x 760) x 1 + (930 x
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 2 (1,240 x1,690 x 760) x 2
1,690 x 760) x 1 1,690 x 760) x 1
(1,280 x 1,825 x 796) x 1 + (960 x (1,280 x 1,825 x 796) x 1 + (960 x
Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 2 (1,280 x 1,825 x 796) x 2
1,825 x 796) x 1 1,825 x 796) x 1
Net Weight kg x No. (300 x 1) + (215 x 1) (310 x 1) + (215 x 1) (310 x 1) + (237 x 1) (310 x 1) + (237 x 1)
Shipping Weight kg x No. (312 x 1) + (225 x 1) (320 x 1) + (225 x 1) (320 x 1) + (250 x 1) (320 x 1) + (250 x 1)
Sound Pressure Cooling dB(A) 65.6 66.0 66.2 66.3
Level Heating dB(A) 66.6 67.8 68.0 68.1
Sound Cooling dB(A) 93.8 95.5 96.0 96.2
Power Level Heating dB(A) 97.6 99.4 100.0 100.2
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A R410A
Precharged Amount
kg 25.5 26.5 30.5 30.5
Refrigerant in Factory
t-CO2eq 53.2 55.3 63.7 63.7
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 55 (64) 58 (64) 61 (64) 64

1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected.The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160%
~ 200%). The recommended ratio is 130%.
MULTI V 5 HEAT RECOVERY
ARUM420LTE5 / ARUM440LTE5
ARUM460LTE5 / ARUM480LTE5

HP 42 44 46 48
Combination Unit ARUM420LTE5 ARUM440LTE5 ARUM460LTE5 ARUM480LTE5
Model Name ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
Independent Unit
ARUM180LTE5 ARUM200LTE5 ARUM220LTE5 ARUM240LTE5
Cooling (Rated) kW 117.6 123.2 128.8 134.4
Btu/h 401,300 420,400 439,500 458,600
Heating (Rated) kW 117.6 123.2 128.8 134.4
Capacity
Btu/h 401,300 420,400 439,500 458,600
Heating (Max) kW 131.0 137.3 143.6 148.5
Btu/h 446,800 468,300 489,800 506,700
Cooling (Rated) kW 28.44 30.17 33.33 34.82
Input Heating (Rated) kW 26.01 28.09 30.04 31.78
Heating (Max) kW 30.74 33.49 35.56 37.60
COP Cooling (Rated) 4.14 4.08 3.86 3.86
Heating (Rated) 4.52 4.39 4.29 4.23
COP
Heating (Max) 4.26 4.10 4.04 3.95
SCOP - - - -
Exterior Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 4 (Inverter) x 4 (Inverter) x 4 (Inverter) x 4
Compressor Motor Output x Number W x No. (5,300 x 3) + (4,200 x 1) (5,300 x 3) + (4,200 x 1) (5,300 x 3) + (4,200 x 1) 5,300 x 4
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 10,400 10,400 10,400 10,400
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W x No. 900 x 4 900 x 4 900 x 4 900 x 4
Fan Air Flow Rate (High) m3/min x No. 320 x 2 320 x 2 320 x 2 320 x 2
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Pipe Connections
Low Pressure Gas Pipe mm (inch) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8)
for Heat Recovery
High Pressure Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8)
Pipe Connections Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
for Heat Pump Gas Pipe mm (inch) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8)
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 2 (1,240 x1,690 x 760) x 2 (1,240 x1,690 x 760) x 2 (1,240 x1,690 x 760) x 2
Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 2 (1,280 x 1,825 x 796) x 2 (1,280 x 1,825 x 796) x 2 (1,280 x 1,825 x 796) x 2
Net Weight kg x No. (310 x 1) + (300 x 1) (310 x 1) + (300 x 1) (310 x 1) + (300 x 1) 310 x 2
Shipping Weight kg x No. (320 x 1) + (312 x 1) (320 x 1) + (312 x 1) (320 x 1) + (312 x 1) 320 x 2
Sound Pressure Cooling dB(A) 66.5 66.8 67.8 68.0
Level Heating dB(A) 68.2 68.9 69.3 70.0
Sound Cooling dB(A) 96.8 97.1 97.1 98.0
Power Level Heating dB(A) 100.5 100.8 101.1 102.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A R410A
Precharged Amount
kg 33.0 33.0 33.0 34.0
Refrigerant in Factory
t-CO2eq 68.9 68.9 68.9 71.0
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 64 64 64 64

1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected.The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160%
~ 200%). The recommended ratio is 130%.

044 / 045
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION

MULTI V 5 HEAT RECOVERY


ARUM500LTE5 / ARUM520LTE5
ARUM540LTE5 / ARUM560LTE5

HP 50 52 54 56
Combination Unit ARUM500LTE5 ARUM520LTE5 ARUM540LTE5 ARUM560LTE5
Model Name ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
Independent Unit ARUM140LTE5 ARUM160LTE5 ARUM180LTE5 ARUM200LTE5
ARUM120LTE5 ARUM120LTE5 ARUM120LTE5 ARUM120LTE5
Cooling (Rated) kW 140 145.6 151.2 156.8
Btu/h 477,700 496,800 515,900 535,000
Heating (Rated) kW 140 145.6 151.2 156.8
Capacity
Btu/h 477,700 496,800 515,900 535,000
Heating (Max) kW 156.2 162.5 168.8 175.1
Btu/h 532,800 554,300 575,800 597,300
Cooling (Rated) kW 33.79 36.02 36.14 37.87
Input Heating (Rated) kW 30.87 33.02 32.86 34.94
Heating (Max) kW 36.78 39.45 39 41.75
COP Cooling (Rated) 4.14 4.04 4.18 4.14
Heating (Rated) 4.54 4.41 4.6 4.49
COP
Heating (Max) 4.25 4.12 4.33 4.19
SCOP - - - -
Exterior Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 4 (Inverter) x 4 (Inverter) x 5 (Inverter) x 5
Compressor Motor Output x Number W x No. 5,300 x 4 5,300 x 4 (5,300 x 4) + (4,200 x 1) (5,300 x 4) + (4,200 x 1)
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 13,000 13,000 14,300 14,300
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W x No. (900 x 4) + (1,200 x 1) (900 x 4) + (1,200 x 1) (900 x 4) + (1,200 x 1) (900 x 4) + (1,200 x 1)
Fan Air Flow Rate (High) m3/min x No. (320 x 2) + (240 x 1) (320 x 2) + (240 x 1) (320 x 2) + (240 x 1) (320 x 2) + (240 x 1)
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Pipe Connections
Low Pressure Gas Pipe mm (inch) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8)
for Heat Recovery
High Pressure Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8)
Pipe Connections Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
for Heat Pump Gas Pipe mm (inch) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8)
(1,240 x 1,690 x 760) x 2 + (930 x (1,240 x 1,690 x 760) x 2 + (930 x (1,240 x 1,690 x 760) x 2 + (930 x (1,240 x 1,690 x 760) x 2 + (930 x
Dimensions (W x H x D) mm x No.
1,690 x 760) x 1 1,690 x 760) x 1 1,690 x 760) x 1 1,690 x 760) x 1
(1,280 x 1,825 x 796) x 2 + (960 x (1,280 x 1,825 x 796) x 2 + (960 x (1,280 x 1,825 x 796) x 2 + (960 x (1,280 x 1,825 x 796) x 2 + (960 x
Dimensions (W x H x D) - Shipping mm x No.
1,825 x 796) x 1 1,825 x 796) x 1 1,825 x 796) x 1 1,825 x 796) x 1
Net Weight kg x No. (310 x 1) + (237 x 1) + (215 x 1) (310 x 1) + (237 x 1) + (215 x 1) (310 x 1) + (300 x 1) + (215 x 1) (310 x 1) + (300 x 1) + (215 x 1)
(320 x 1) + (312 x 1) + (320 x 1) + (312 x 1) +
Shipping Weight kg x No. (320 x 1) + (250 x 1) + (225 x 1) (320 x 1) + (250 x 1) + (225 x 1)
(225 x 1) (225 x 1)
Sound Pressure Cooling dB(A) 67 67.1 67.2 67.4
Level Heating dB(A) 68.6 68.7 68.8 69.5
Sound Cooling dB(A) 96.4 96.6 97.1 97.4
Power Level Heating dB(A) 100.3 100.5 100.8 101
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A R410A
Precharged Amount
kg 40 40 42.5 42.5
Refrigerant in Factory
t-CO2eq 83.5 83.5 88.7 88.7
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 64 64 64 64

1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected.The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160%
~ 200%). The recommended ratio is 130%.
MULTI V 5 HEAT RECOVERY
ARUM580LTE5 / ARUM600LTE5
ARUM620LTE5 / ARUM640LTE5
ARUM660LTE5

HP 58 60 62 64 66
Combination Unit ARUM580LTE5 ARUM600LTE5 ARUM620LTE5 ARUM640LTE5 ARUM660LTE5
Model Name ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
Independent Unit ARUM220LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
ARUM120LTE5 ARUM120LTE5 ARUM140LTE5 ARUM160LTE5 ARUM180LTE5
Cooling (Rated) kW 162.4 168.0 173.6 179.2 184.8
Btu/h 554,100 573,200 592,300 611,400 630,500
Heating (Rated) kW 162.4 168.0 173.6 179.2 184.8
Capacity
Btu/h 554,100 573,200 592,300 611,400 630,500
Heating (Max) kW 181.4 186.3 192.6 198.9 205.2
Btu/h 618,800 635,700 657,200 678,700 700,200
Cooling (Rated) kW 41.03 42.53 43.49 45.72 45.85
Input Heating (Rated) kW 36.89 38.63 39.91 42.06 41.90
Heating (Max) kW 43.82 45.86 47.32 49.99 49.54
COP Cooling (Rated) 3.96 3.95 3.99 3.92 4.03
Heating (Rated) 4.40 4.35 4.35 4.26 4.41
COP
Heating (Max) 4.14 4.06 4.07 3.98 4.14
SCOP - - - - -
Exterior Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 5 (Inverter) x 5 (Inverter) x 5 (Inverter) x 5 (Inverter) x 6
Compressor Motor Output x Number W x No. (5,300 x 4) + (4,200 x 1) 5,300 x 5 5,300 x 5 5,300 x 5 (5,300 x 5) + (4,200 x 1)
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 14,300 14,300 14,300 14,300 15,600
Type Propeller fan Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W x No. (900 x 4) + (1,200 x 1) (900 x 4) + (1,200 x 1) 900 x 6 900 x 6 900 x 6
Fan Air Flow Rate (High) m3/min x No. (320 x 2) + (240 x 1) (320 x 2) + (240 x 1) 320 x 3 320 x 3 320 x 3
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP TOP
Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8)
Pipe Connections
Low Pressure Gas Pipe mm (inch) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø53.98 (2-1/8)
for Heat Recovery
High Pressure Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø41.3 (1-5/8)
Pipe Connections Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8)
for Heat Pump Gas Pipe mm (inch) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø53.98 (2-1/8)
(1,240 x 1,690 x 760) x 2 + (930 (1,240 x 1,690 x 760) x 2 + (930
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 3 (1,240 x1,690 x 760) x 3 (1,240 x1,690 x 760) x 3
x 1,690 x 760) x 1 x 1,690 x 760) x 1
(1,280 x 1,825 x 796) x 2 + (1,280 x 1,825 x 796) x 2 +
Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3
(960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1
(310 x 1) + (300 x 1) +
Net Weight kg x No. (310 x 2) + (215 x 1) (310 x 2) + (237 x 1) (310 x 2) + (237 x 1) (310 x 2) + (300 x 1)
(215 x 1)
(320 x 1) + (312 x 1) +
Shipping Weight kg x No. (320 x 2) + (225 x 1) (320 x 2) + (250 x 1) (320 x 2) + (250 x 1) (320 x 2) + (312 x 1)
(225 x 1)
Sound Pressure Cooling dB(A) 68.3 68.5 68.6 68.7 68.8
Level Heating dB(A) 69.8 70.4 70.5 70.6 70.6
Sound Cooling dB(A) 97.4 98.3 98.5 98.6 99.0
Power Level Heating dB(A) 101.4 102.2 102.5 102.6 102.8
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A R410A R410A
Precharged Amount
kg 42.5 43.5 47.5 47.5 50.0
Refrigerant in Factory
t-CO2eq 88.7 90.8 99.2 99.2 104.4
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 64 64 64 64 64

1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected.The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160%
~ 200%). The recommended ratio is 130%.

046 / 047
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION

MULTI V 5 HEAT RECOVERY


ARUM680LTE5 / ARUM700LTE5
ARUM720LTE5 / ARUM740LTE5
ARUM760LTE5

HP 68 70 72 74 76
Combination Unit ARUM680LTE5 ARUM700LTE5 ARUM720LTE5 ARUM740LTE5 ARUM760LTE5
ARUM240LTE5 ARUM240LTE5
Model Name ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
ARUM240LTE5 ARUM240LTE5
Independent Unit ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
ARUM140LTE5 ARUM160LTE5
ARUM200LTE5 ARUM220LTE5 ARUM240LTE5
ARUM120LTE5 ARUM120LTE5
Cooling (Rated) kW 190.4 196.0 201.6 207.2 212.8
Btu/h 649,600 668,800 687,900 707,000 726,100
Heating (Rated) kW 190.4 196.0 201.6 207.2 212.8
Capacity
Btu/h 649,600 668,800 687,900 707,000 726,100
Heating (Max) kW 211.5 217.8 222.8 230.4 236.7
Btu/h 721,700 743,200 760,100 786,200 807,700
Cooling (Rated) kW 47.57 50.74 52.23 51.20 53.43
Input Heating (Rated) kW 43.98 45.93 47.67 46.76 48.91
Heating (Max) kW 52.29 54.36 56.40 55.58 58.25
COP Cooling (Rated) 4.00 3.86 3.86 4.05 3.98
Heating (Rated) 4.33 4.27 4.23 4.43 4.35
COP
Heating (Max) 4.05 4.01 3.95 4.15 4.06
SCOP - - - - -
Exterior Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 6 (Inverter) x 6 (Inverter) x 6 (Inverter) x 6 (Inverter) x 6
Compressor Motor Output x Number W x No. (5,300 x 5) + (4,200 x 1) (5,300 x 5) + (4,200 x 1) 5,300 x 6 5,300 x 6 5,300 x 6
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 15,600 15,600 15,600 18,200 18,200
Type Propeller fan Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W x No. 900 x 6 900 x 6 900 x 6 (900 x 6) + (1,200 x 1) (900 x 6) + (1,200 x 1)
Fan Air Flow Rate (High) m3/min x No. 320 x 3 320 x 3 320 x 3 (320 x 3) + (240 x 1) (320 x 3) + (240 x 1)
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP TOP
Liquid Pipe mm (inch) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8)
Pipe Connections
Low Pressure Gas Pipe mm (inch) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8)
for Heat Recovery
High Pressure Gas Pipe mm (inch) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8)
Pipe Connections Liquid Pipe mm (inch) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8)
for Heat Pump Gas Pipe mm (inch) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8)
(1,240 x 1,690 x 760) x 3 + (930 (1,240 x 1,690 x 760) x 3 + (930
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 3 (1,240 x1,690 x 760) x 3 (1,240 x1,690 x 760) x 3
x 1,690 x 760) x 1 x 1,690 x 760) x 1
(1,280 x 1,825 x 796) x 3 + (1,280 x 1,825 x 796) x 3 +
Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3 (1,280 x 1,825 x 796) x 3
(960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1
(310 x 2) + (237 x 1) + (310 x 2) + (237 x 1) +
Net Weight kg x No. (310 x 2) + (300 x 1) (310 x 2) + (300 x 1) 310 x 3
(215 x 1) (215 x 1)
(320 x 2) + (250 x 1) + (320 x 2) + (250 x 1) +
Shipping Weight kg x No. (320 x 2) + (312 x 1) (320 x 2) + (312 x 1) 320 x 3
(225 x 1) (225 x 1)
Sound Pressure Cooling dB(A) 69.0 69.6 69.8 69.1 69.2
Level Heating dB(A) 71.1 71.3 71.8 70.9 70.9
Sound Cooling dB(A) 99.2 99.2 99.8 98.8 98.9
Power Level Heating dB(A) 103.0 103.2 103.8 102.7 102.8
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A R410A R410A
Precharged Amount
kg 50.0 50.0 51.0 57.0 57.0
Refrigerant in Factory
t-CO2eq 104.4 104.4 106.5 119.0 119.0
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 64 64 64 64 64

1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected.The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160%
~ 200%). The recommended ratio is 130%.
MULTI V 5 HEAT RECOVERY
ARUM780LTE5 / ARUM800LTE5
ARUM820LTE5 / ARUM840LTE5
ARUM860LTE5

HP 78 80 82 84 86
Combination Unit ARUM780LTE5 ARUM800LTE5 ARUM820LTE5 ARUM840LTE5 ARUM860LTE5
ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
Model Name ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
Independent Unit
ARUM180LTE5 ARUM200LTE5 ARUM220LTE5 ARUM240LTE5 ARUM240LTE5
ARUM120LTE5 ARUM120LTE5 ARUM120LTE5 ARUM120LTE5 ARUM140LTE5
Cooling (Rated) kW 218.4 224.0 229.6 235.2 240.8
Btu/h 745,200 764,300 783,400 802,500 821,600
Heating (Rated) kW 218.4 224.0 229.6 235.2 240.8
Capacity
Btu/h 745,200 764,300 783,400 802,500 821,600
Heating (Max) kW 243.0 249.3 255.6 260.6 266.9
Btu/h 829,200 850,700 872,100 889,100 910,600
Cooling (Rated) kW 53.55 55.28 58.44 59.93 60.90
Input Heating (Rated) kW 48.75 50.83 52.78 54.52 55.80
Heating (Max) kW 57.80 60.55 62.62 64.66 66.12
COP Cooling (Rated) 4.08 4.05 3.93 3.92 3.95
Heating (Rated) 4.48 4.41 4.35 4.31 4.32
COP
Heating (Max) 4.20 4.12 4.08 4.03 4.04
SCOP - - - - -
Exterior Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 7 (Inverter) x 7 (Inverter) x 7 (Inverter) x 7 (Inverter) x 7
Compressor Motor Output x Number W x No. (5,300 x 6) + (4,200 x 1) (5,300 x 6) + (4,200 x 1) (5,300 x 6) + (4,200 x 1) 5,300 x 7 5,300 x 7
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 19,500 19,500 19,500 19,500 19,500
Type Propeller fan Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W x No. (900 x 6) + (1,200 x 1) (900 x 6) + (1,200 x 1) (900 x 6) + (1,200 x 1) (900 x 6) + (1,200 x 1) 900 x 8
Fan Air Flow Rate (High) m3/min x No. (320 x 3) + (240 x 1) (320 x 3) + (240 x 1) (320 x 3) + (240 x 1) (320 x 3) + (240 x 1) 320 x 4
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP TOP
Liquid Pipe mm (inch) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8)
Pipe Connections
Low Pressure Gas Pipe mm (inch) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8)
for Heat Recovery
High Pressure Gas Pipe mm (inch) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8)
Pipe Connections Liquid Pipe mm (inch) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8)
for Heat Pump Gas Pipe mm (inch) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8)
(1,240 x 1,690 x 760) x 3 + (930 (1,240 x 1,690 x 760) x 3 + (930 (1,240 x 1,690 x 760) x 3 + (930 (1,240 x 1,690 x 760) x 3 + (930
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 4
x 1,690 x 760) x 1 x 1,690 x 760) x 1 x 1,690 x 760) x 1 x 1,690 x 760) x 1
(1,280 x 1,825 x 796) x 3 + (1,280 x 1,825 x 796) x 3 + (1,280 x 1,825 x 796) x 3 + (1,280 x 1,825 x 796) x 3 +
Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 4
(960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1 (960 x 1,825 x 796) x 1
(310 x 2) + (300 x 1) + (310 x 2) + (300 x 1) + (310 x 2) + (300 x 1) +
Net Weight kg x No. (310 x 3) + (215 x 1) (310 x 3) + (237 x 1)
(215 x 1) (215 x 1) (215 x 1)
(320 x 2) + (312 x 1) + (320 x 2) + (312 x 1) + (320 x 2) + (312 x 1) +
Shipping Weight kg x No. (320 x 3) + (225 x 1) (320 x 3) + (250 x 1)
(225 x 1) (225 x 1) (225 x 1)
Sound Pressure Cooling dB(A) 69.2 69.4 70.0 70.1 70.2
Level Heating dB(A) 71.0 71.4 71.6 72.1 72.1
Sound Cooling dB(A) 99.2 99.4 99.4 99.9 100.1
Power Level Heating dB(A) 103.0 103.2 103.4 103.9 104.1
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A R410A R410A
Precharged Amount
kg 59.5 59.5 59.5 60.5 64.5
Refrigerant in Factory
t-CO2eq 124.2 124.2 124.2 126.3 134.6
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 64 64 64 64 64

1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected.The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160%
~ 200%). The recommended ratio is 130%.

048 / 049
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION

MULTI V 5 HEAT RECOVERY


ARUM880LTE5 / ARUM900LTE5
ARUM920LTE5 / ARUM940LTE5
ARUM960LTE5

HP 88 90 92 94 96
Combination Unit ARUM880LTE5 ARUM900LTE5 ARUM920LTE5 ARUM940LTE5 ARUM960LTE5
ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
Model Name ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
Independent Unit
ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5 ARUM240LTE5
ARUM160LTE5 ARUM180LTE5 ARUM200LTE5 ARUM220LTE5 ARUM240LTE5
Cooling (Rated) kW 246.4 252.0 257.6 263.2 268.8
Btu/h 840,700 859,800 878,900 898,000 917,100
Heating (Rated) kW 246.4 252.0 257.6 263.2 268.8
Capacity
Btu/h 840,700 859,800 878,900 898,000 917,100
Heating (Max) kW 273.2 279.5 285.8 292.1 297.0
Btu/h 932,000 953,500 975,000 996,500 1,013,400
Cooling (Rated) kW 63.13 63.26 64.98 68.15 69.64
Input Heating (Rated) kW 57.95 57.79 59.87 61.82 63.56
Heating (Max) kW 68.79 68.34 71.09 73.16 75.20
COP Cooling (Rated) 3.90 3.98 3.96 3.86 3.86
SEER - - - - -
Heating (Rated) 4.25 4.36 4.30 4.26 4.23
COP
Heating (Max) 3.97 4.09 4.02 3.99 3.95
SCOP - - - - -
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL Code (Classic) NL503K / NA507K NL503K / NA507K NL503K / NA507K NL503K / NA507K NL503K / NA507K
Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 7 (Inverter) x 8 (Inverter) x 8 (Inverter) x 8 (Inverter) x 8
Compressor Motor Output x Number W x No. 5,300 x 7 (5,300 x 7) + (4,200 x 1) (5,300 x 7) + (4,200 x 1) (5,300 x 7) + (4,200 x 1) 5,300 x 8
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 19,500 20,800 20,800 20,800 20,800
Type Propeller fan Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W x No. 900 x 8 900 x 8 900 x 8 900 x 8 900 x 8
Fan Air Flow Rate (High) m3/min x No. 320 x 4 320 x 4 320 x 4 320 x 4 320 x 4
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP TOP
Liquid Pipe mm (inch) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8)
Pipe Connections
Low Pressure Gas Pipe mm (inch) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8)
for Heat Recovery
High Pressure Gas Pipe mm (inch) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8)
Pipe Connections Liquid Pipe mm (inch) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8)
for Heat Pump Gas Pipe mm (inch) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8)
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 4 (1,240 x1,690 x 760) x 4 (1,240 x1,690 x 760) x 4 (1,240 x1,690 x 760) x 4 (1,240 x1,690 x 760) x 4
Dimensions (W x H x D) - Shipping mm x No. (1,280 x 1,825 x 796) x 4 (1,280 x 1,825 x 796) x 4 (1,280 x 1,825 x 796) x 4 (1,280 x 1,825 x 796) x 4 (1,280 x 1,825 x 796) x 4
Net Weight kg x No. (310 x 3) + (237 x 1) (310 x 3) + (300 x 1) (310 x 3) + (300 x 1) (310 x 3) + (300 x 1) 310 x 4
Shipping Weight kg x No. (320 x 3) + (250 x 1) (320 x 3) + (312 x 1) (320 x 3) + (312 x 1) (320 x 3) + (312 x 1) 320 x 4
Sound Pressure Cooling dB(A) 70.3 70.3 70.4 70.9 71.0
Level Heating dB(A) 72.2 72.2 72.5 72.7 73.0
Sound Cooling dB(A) 100.2 100.4 100.6 100.6 101.0
Power Level Heating dB(A) 104.2 104.3 104.4 104.6 105.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A R410A R410A
Precharged Amount
kg 64.5 67.0 67.0 67.0 68.0
Refrigerant in Factory
t-CO2eq 134.6 139.9 139.9 139.9 142.0
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 64 64 64 64 64

1) Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected.The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160%
~ 200%). The recommended ratio is 130%.
OUTDOOR UNIT _ MULTI V 5 _ NOTE

NOTE
1. Eurovent Test Condition : For more info regarding program consult www.eurovent-certification.com

2. Capacities are based on the following conditions :


• *Cooling : Indoot Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
• *Heating : Indoot Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
.• Piping Length : Interconnected Pipe Length = 7.5m
• Difference Limit of Elevation (Outdoor ~ Indoor Unit) is 0m.

3. Wiring cable size must comply with the applicable local and national code.

4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.

5. Explanation of Terms
• EER : Energy Efficiency Ratio (Cooling)
• COP : Coefficient Of Performance (Heating)
• SCOP : Seasonal Coefficient Of Performance (Refer to Typical Heating Season)

6. Due to our policy of innovation some specifications may be changed without notification.

7. This product contains Fluorinated greenhouse gases.(R410A)

050 / 051
OUTDOOR UNITS _ MULTI V 5 _ TECHNICAL DATA

ARUM080LTE5 / ARUM100LTE5 / ARUM120LTE5


[Unit : mm] No. Part Name Description
1 Leakage test hole (Side) Ø22.2
2 Wire routing hole (Bottom) 2-Ø22.2
3 Power cord routing hole (Bottom) 2-Ø50
4 Pipe routing hole (Front) -
5 Pipe routing hole (Bottom) 2-Ø66, Ø53.88
6 Power cord routing hole (Front) 2-Ø45

ARUM080LTE5 / ARUM100LTE5 / ARUM120LTE5


7 Wire routing hole (Front) 2-Ø30
yavity
point

2. Dimensions
Multi V 5
Gravity point
point Gravity
Gravity point point

3D View

1,690

[mm(inch)]
799

System Heat Recovery Heat Pump


Liquid Low Pressure High Pressure Liquid Gas
HP
pipe Gas pipe Gas pipe pipe pipe
165
92 175

8 Ø 9.52 (3/8) Ø 19.05 (3/4) Ø 15.88 (5/8) Ø 9.52 (3/8) Ø 19.05 (3/4)
219

10 Ø 9.52 (3/8) Ø 22.2 (7/8) Ø 19.05 (3/4) Ø 9.52 (3/8) Ø 22.2 (7/8)
162
141

12 Ø 12.7 (1/2) Ø 28.58 (1-1/8) Ø 19.05 (3/4) Ø 12.7 (1/2) Ø 28.58 (1-1/8)

144 159 71 71
462
625 414
670
675 760
735
740
930
Outdoor Units

System Hea
System
System
333 System
Liquid
HP Low
Liquid
HP pipe HP
312 pipe G
HP
298 8 Ø 9.52 (3/8) 8 Ø 19
8 Ø 9.52 (3/8)
Ø 9.52 (3/8)810 Ø 22
Ø
245
10
236
10 Ø 9.52 (3/8)
10 Ø
12 Ø 12.7 (1/2)12Ø 28.
185 12 Ø 12.7 (1/2)
156 12 Ø
76
114
172

(Pitch of foundation bolt holes)


731

101 730

(Pitch of foundation bolt holes)


ARUM140LTE5 / ARUM160LTE5 / ARUM180LTE5 / ARUM200LTE5
ARUM220LTE5 / ARUM240LTE5 / ARUM260LTE5
[Unit : mm] No. Part Name Description
1 Leakage test hole (Side) Ø22.2
2 Wire routing hole (Bottom) 2-Ø22.2
3 Power cord routing hole (Bottom) 2-Ø50
4 Pipe routing hole (Front) -
5 Pipe routing hole (Bottom) 2-Ø66, Ø53.88
6 Power cord routing hole (Front) 2-Ø45
7 Wire routing hole (Front) 2-Ø30

ARUM220LTE5 / ARUM240LTE5 / ARUM260LTE5


ARUM140LTE5 / ARUM160LTE5 / ARUM180LTE5 / ARUM200LTE5

2. Dimensions
Multi V 5
3D View

[mm(inch)]
1,690

System Heat Recovery Heat Pump


Liquid Low Pressure High Pressure Liquid Gas
HP
pipe Gas pipe Gas pipe pipe pipe

14~16 Ø 12.7 (1/2) Ø 28.58 (1-1/8) Ø 22.2 (7/8) Ø 12.7 (1/2) Ø 28.58 (1-1/8)
18~20 Ø 15.88 (5/8) Ø 28.58 (1-1/8) Ø 22.2 (7/8) Ø 15.88 (5/8) Ø 28.58 (1-1/8)

22 Ø 15.88 (5/8) Ø 28.58(1-1/8) Ø 28.58 (1-1/8) Ø 15.88 (5/8) Ø 28.58 (1-1/8)


705

24 Ø 15.88 (5/8) Ø 34.9(1-3/8) Ø 28.58 (1-1/8) Ø 15.88 (5/8) Ø 34.9 (1-3/8)

165 26~34 Ø 19.05 (3/4) Ø 34.9 (1-3/8) Ø 28.58 (1-1/8) Ø 19.05 (3/4) Ø 34.9 (1-3/8)
92 176

36~40 Ø 19.05 (3/4) Ø 41.3 (1-5/8) Ø 28.58 (1-1/8) Ø 19.05 (3/4) Ø 41.3 (1-5/8)
220
162
140

42~60 Ø 19.05 (3/4) Ø 41.3 (1-5/8) Ø 34.9 (1-3/8) Ø 19.05 (3/4) Ø 41.3 (1-5/8)

62~64 Ø 22.2 (7/8) Ø 44.5 (1-3/4) Ø 41.3 (1-5/8) Ø 22.2 (7/8) Ø 44.5 (1-3/4)
138 159 System
66~96 Ø 22.2 (7/8) Ø 53.98 (2-1/8) Ø 44.5 (1-3/4) Ø 22.2 (7/8) Ø 53.98 (2-1/8) 71 71
439
System Liquid
Sy
444 442.5 HP System
503
pipe
760 Liquid
508 HP
14~16 Øpipe HP(1H
12.7
593
1,240 14~16 Ø 15.88
18~20Ø 12.7 14(
(1/2)
14~16
18~20 Ø 15.88
22 Ø 15.88 18(
(5/8
18~20
302
Ø 15.88
22 24 Ø 15.88 (5/8(2
22
Outdoor Units

280

267
26~34Ø 15.88
24 Ø 19.05
(5/8(2
24

214 36~40Ø 19.05


26~34 Ø 19.05
26(
(3/4
26~34
205 42~60Ø 19.05
36~40 Ø 19.05
36(
(3/4
36~40
154
62~64Ø 19.05
42~60 Ø 22.2 (7
(3/4
42
42~60
125
66~96Ø 22.2
62~64 Ø 22.2 (7
(7/8)
62
62~64
109
121

92

66~96 Ø 22.266~96
(7/8)
66
(Pitch of foundation bolt holes)
189

76

100 1,040

(Pitch of foundation bolt holes)

052 / 053
HEAT PUMP
- Air Cooled VRF Heat Pump
- 22.4kW ~ 268.8kW (Cooling capacity based)
- 3Ø, 380 ~ 415V, 50Hz
- Top discharge outdoor unit

TOTAL PIPING LENGTH

Designed
Design
For
For
The Ultimate
The Ultimate
1,000m 225m
TOTAL PIPING LENGTH Longest Piping Length

Piping capabilities

between ODU ~ IDU


Height Difference
Total Piping Length 1,000m

110m
Actual longest piping length (Equivalent) 200m (225m)
Longest piping length after 1st branch (conditional application) 40m (90m)
Height between ODU ~ IDU 110m
Height between IDU ~ IDU 40m
Height between ODU ~ ODU 5m

between IDU ~ IDU


Height Difference
40m
How does it work?
Dual Sensing

Energy savings

Partial Defrost
Reliability

Low noise

Advanced performance

054 / 055
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION

MULTI V 5 HEAT PUMP


ARUN080LTE5 / ARUN100LTE5
ARUN120LTE5 / ARUN140LTE5

HP 8 10 12 14
Combination Unit ARUN080LTE5 ARUN100LTE5 ARUN120LTE5 ARUN140LTE5
Model Name
Independent Unit ARUN080LTE5 ARUN100LTE5 ARUN120LTE5 ARUN140LTE5
kW 22.4 28.0 33.6 39.2
Cooling (Rated) Btu/h*1 76,400 95,500 114,600 133,800
Capacity Btu/h*2 78,300 96,200 115,300 134,400
kW 25.2 31.5 37.8 44.1
Heating (Rated)
Btu/h 86,000 107,500 129,000 150,500
Cooling (Rated) kW 4.59 5.70 7.91 9.12
Input
Heating (Rated) kW 4.74 5.78 8.06 9.78
COP Cooling (Rated) 4.88 4.91 4.25 4.30
COP Heating (Rated) 5.32 5.45 4.69 4.51
Power Factor Rated - 0.93 0.93 0.93 0.93
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL code RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037
Heat Exchanger Wide Louver Plus Wide Louver Plus Wide Louver Plus Wide Louver Plus
Compressor Motor Output x Number W x No. 5,300 x 1 5,300 x 1 5,300 x 1 5,300 x 1
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W 1,200 x 1 1,200 x 1 1,200 x 1 900 x 2
m3/min 240 x 1 240 x 1 240 x 1 320 x 1
Air Flow Rate (High)
Fan ft3/min 8,476 x 1 8,476 x 1 8,476 x 1 11,301 x 1
External Static Pressure (Max, Pa) 80 80 80 80
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) 9.52 (3/8) 9.52 (3/8) 12.7 (1/2) 12.7 (1/2)
Connections Gas Pipe mm (inch) 19.05 (3/4) 22.2 (7/8) 28.58 (1-1/8) 28.58 (1-1/8)
Dimensions (W x H x D) mm x No. (930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1
Net Weight kg 199 x 1 199 x 1 199 x 1 221 x 1
Sound Pressure Cooling dB(A) 58.0 58.0 59.0 60.0
Level Heating dB(A) 59.0 59.0 60.0 61.0
Sound Cooling dB(A) 78.0 78.0 79.0 82.0
Power Level Heating dB(A) 79.0 79.0 80.0 84.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A R410A R410A
Precharged Amount kg 10.0 10.0 10.0 13.0
Refrigerant in factory lbs 22.0 22.0 22.0 28.7
t-CO2eq 20.9 20.9 20.9 27.1
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Number of maximum connectable indoor units 13 (20) 16 (25) 20 (30) 23 (35)

Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design.
Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*1 Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
*2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination.
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
MULTI V 5 HEAT PUMP
ARUN160LTE5 / ARUN180LTE5
ARUN200LTE5 / ARUN220LTE5

HP 16 18 20 22
Combination Unit ARUN160LTE5 ARUN180LTE5 ARUN200LTE5 ARUN220LTE5
Model Name
Independent Unit ARUN160LTE5 ARUN180LTE5 ARUN200LTE5 ARUN220LTE5
kW 44.8 50.4 56.0 61.6
Cooling (Rated) Btu/h*1 152,900 172,000 191,100 210,200
Capacity Btu/h*2 153,900 173,000 192,400 211,500
kW 50.4 56.7 63.0 69.3
Heating (Rated)
Btu/h 172,000 193,500 215,000 236,500
Cooling (Rated) kW 10.80 10.96 12.31 14.84
Input
Heating (Rated) kW 11.59 12.06 15.52 17.54
COP Cooling (Rated) 4.15 4.60 4.55 4.15
COP Heating (Rated) 4.35 4.70 4.06 3.95
Power Factor Rated - 0.93 0.93 0.93 0.93
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL code RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037
Heat Exchanger Wide Louver Plus Wide Louver Plus Wide Louver Plus Wide Louver Plus
Compressor Motor Output x Number W x No. 5,300 x 1 5,300 x 1 + 4,200 x 1 5,300 x 2 5,300 x 2
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W 900 x 2 900 x 2 900 x 2 900 x 2
m3/min 320 x 1 320 x 1 320 x 1 320 x 1
Air Flow Rate (High)
Fan ft3/min 11,301 x 1 11,301 x 1 11,301 x 1 11,301 x 1
External Static Pressure (Max, Pa) 80 80 80 80
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) 12.7 (1/2) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8)
Connections Gas Pipe mm (inch) 28.58 (1-1/8) 28.58 (1-1/8) 28.58 (1-1/8) 28.58 (1-1/8)
Dimensions (W x H x D) mm x No. (1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1
Net Weight kg 221 x 1 261 x 1 281 x 1 281 x 1
Sound Pressure Cooling dB(A) 60.5 61.0 62.0 64.5
Level Heating dB(A) 61.5 62.0 64.5 65.5
Sound Cooling dB(A) 83.0 85.0 86.0 86.0
Power Level Heating dB(A) 85.0 86.0 87.0 88.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A R410A R410A
Precharged Amount kg 13.0 13.0 14.0 14.0
Refrigerant in factory lbs 28.7 28.7 30.9 30.9
t-CO2eq 27.1 27.1 29.2 29.2
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Number of maximum connectable indoor units 26 (40) 29 (45) 32 (50) 35 (56)

Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design.
Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*1 Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
*2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination.
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)

056 / 057
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION

MULTI V 5 HEAT PUMP


ARUN240LTE5 / ARUN260LTE5

HP 24 26
Combination Unit ARUN240LTE5 ARUN260LTE5
Model Name
Independent Unit ARUN240LTE5 ARUN260LTE5
kW 67.2 72.8
Cooling (Rated)
Btu/h*1 229,300 248,400
Capacity Btu/h*2 230,700 249,800
kW 74.3 74.3
Heating (Rated)
Btu/h 253,400 253,400
Cooling (Rated) kW 16.76 19.41
Input
Heating (Rated) kW 18.85 19.49
COP Cooling (Rated) 4.01 3.75
COP Heating (Rated) 3.94 3.81
Power Factor Rated - 0.93 0.93
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL code RAL 7030 / RAL 7037 RAL 7030 / RAL 7037
Heat Exchanger Wide Louver Plus Wide Louver Plus
Compressor Motor Output x Number W x No. 5,300 x 2 5,300 x 2
Type Propeller fan Propeller fan
Motor Output x Number W 900 x 2 900 x 2
m3/min 320 x 1 320 x 1
Air Flow Rate (High)
Fan ft3/min 11,301 x 1 11,301 x 1
External Static Pressure (Max, Pa) 80 80
Drive DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP
Pipe Liquid Pipe mm (inch) 15.88 (5/8) 19.05 (3/4)
Connections Gas Pipe mm (inch) 34.9 (1-3/8) 34.9 (1-3/8)
Dimensions (W x H x D) mm x No. (1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1
Net Weight kg 283 x 1 283 x 1
Sound Pressure Cooling dB(A) 65.0 65.0
Level Heating dB(A) 67.0 67.0
Sound Cooling dB(A) 88.0 88.0
Power Level Heating dB(A) 90.0 90.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A
Precharged Amount kg 16.0 16.0
Refrigerant in factory lbs 35.3 35.3
t-CO2eq 33.4 33.4
Control Electronic Expansion Valve Electronic Expansion Valve
3, 380-415, 50 3, 380-415, 50
Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60
Number of maximum connectable indoor units 39 (61) 42 (64)

Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design.
Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*1 Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
*2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination.
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
MULTI V 5 HEAT PUMP
ARUN280LTE5 / ARUN300LTE5
ARUN320LTE5

HP 28 30 32
Combination Unit ARUN280LTE5 ARUN300LTE5 ARUN320LTE5
Model Name ARUN160LTE5 ARUN180LTE5 ARUN200LTE5
Independent Unit
ARUN120LTE5 ARUN120LTE5 ARUN120LTE5
kW 78.4 84.0 89.6
Cooling (Rated) Btu/h*1 267,500 286,600 305,700
Capacity Btu/h*2 269,200 288,300 307,800
kW 88.2 94.5 100.8
Heating (Rated)
Btu/h 301,000 322,500 344,000
Cooling (Rated) kW 18.70 18.86 20.21
Input
Heating (Rated) kW 19.65 20.12 23.58
COP Cooling (Rated) 4.19 4.45 4.43
COP Heating (Rated) 4.49 4.70 4.28
Power Factor Rated - 0.93 0.93 0.93
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL code RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037
Heat Exchanger Wide Louver Plus Wide Louver Plus Wide Louver Plus
Compressor Motor Output x Number W x No. 5,300 x 2 (5,300 x 2) + (4,200 x 1) (5,300 x 2) + (4,200 x 1)
Type Propeller fan Propeller fan Propeller fan
Motor Output x Number W (900 x 2) + (1,200 x 1) (900 x 2) + (1,200 x 1) (900 x 2) + (1,200 x 1)
m3/min (320 x 1) + (240 x 1) (320 x 1) + (240 x 1) (320 x 1) + (240 x 1)
Air Flow Rate (High)
Fan ft3/min (11,301 x 1) + (8,476 x 1) (11,301 x 1) + (8,476 x 1) (11,301 x 1) + (8,476 x 1)
External Static Pressure (Max, Pa) 80 80 80
Drive DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP
Pipe Liquid Pipe mm (inch) 19.05 (3/4) 19.05 (3/4) 19.05 (3/4)
Connections Gas Pipe mm (inch) 34.9 (1-3/8) 34.9 (1-3/8) 34.9 (1-3/8)
(1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1
Dimensions (W x H x D) mm x No.
+ (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1
Net Weight kg (221 x 1) + (199 x 1) (261 x 1) + (199 x 1) (281 x 1) + (199 x 1)
Sound Pressure Cooling dB(A) 62.8 63.1 63.8
Level Heating dB(A) 63.8 64.1 65.8
Sound Cooling dB(A) 84.5 86.0 86.8
Power Level Heating dB(A) 86.2 87.0 87.8
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A R410A
Precharged Amount kg 13.0 + 10.0 13.0 + 10.0 14.0 + 10.0
Refrigerant in factory lbs 28.7 + 22.0 28.7 + 22.0 30.9 + 22.0
t-CO2eq 48.0 48.0 50.1
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60
Number of maximum connectable indoor units 45 (56) 49 (60) 52 (64)

Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design.
Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*1 Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
*2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination.
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)

058 / 059
MULTI V 5 HEAT PUMP
ARUN300LTN5 / ARUN320LTN5

HP 30' 32'
Combination Unit ARUN300LTN5 ARUN320LTN5
Model Name
Independent Unit ARUN300LTN5 ARUN320LTN5
kW 84.0 89.6
Cooling (Rated)
Btu/h*1 286,600 305,700
Capacity Btu/h*2 288,300 307,800
kW 94.5 100.8
Heating (Rated)
Btu/h 322,400 343,900
Cooling (Rated) kW 22.40 27.15
Input
Heating (Rated) kW 22.00 24.90
COP Cooling (Rated) 3.75 3.30
COP Heating (Rated) 4.30 4.05
Power Factor Rated - 0.93 0.93
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL code RAL 7030 / RAL 7037 RAL 7030 / RAL 7037
Heat Exchanger Wide Louver Plus Wide Louver Plus
Compressor Motor Output x Number W x No. 5,300 x 2 5,300 x 2
Type Propeller Fan Propeller Fan
Motor Output x Number W 1,500 x 2 1,500 x 2
m3/min 430 x 2 430 x 2
Air Flow Rate (High)
Fan ft3/min 15,185 x 2 15,185 x 2
External Static Pressure (Max, Pa) 80 80
Drive DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP
Pipe Liquid Pipe mm (inch) 19.05 (3/4) 19.05 (3/4)
Connections Gas Pipe mm (inch) 34.9 (1-3/8) 34.9 (1-3/8)
Dimensions (W x H x D) mm x No. (1,640 x 1,690 x 760) x 1 (1,640 x 1,690 x 760) x 1
Net Weight kg 362 x 1 362 x 1
Sound Pressure Cooling dB(A) 65.0 65.0
Level Heating dB(A) 67.0 67.0
Sound Cooling dB(A) 88.0 88.0
Power Level Heating dB(A) 90.0 90.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A
Precharged Amount kg 17.5 17.5
Refrigerant in factory lbs 38.6 38.6
t-CO2eq 36.5 36.5
Control Electronic Expansion Valve Electronic Expansion Valve
3, 380-415, 50 3, 380-415, 50
Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60
Number of maximum connectable indoor units 49 (60) 52 (64)

Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design.
Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*1 Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
*2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination.
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
MULTI V 5 HEAT PUMP
ARUN340LTE5 / ARUN360LTE5
ARUN380LTE5 / ARUN400LTE5

HP 34 36 38 40
Combination Unit ARUN340LTE5 ARUN360LTE5 ARUN380LTE5 ARUN400LTE5
Model Name ARUN220LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
Independent Unit
ARUN120LTE5 ARUN120LTE5 ARUN140LTE5 ARUN160LTE5
kW 95.2 100.8 106.4 112.0
Cooling (Rated) Btu/h*1 324,800 343,900 363,100 382,200
Capacity Btu/h*2 326,900 346,300 356,400 384,900
kW 107.1 112.1 118.4 124.7
Heating (Rated)
Btu/h 365,500 382,400 403,900 425,400
Cooling (Rated) kW 22.75 24.66 25.87 27.55
Input
Heating (Rated) kW 25.60 26.91 28.62 30.43
COP Cooling (Rated) 4.18 4.09 4.11 4.06
COP Heating (Rated) 4.18 4.16 4.13 4.10
Power Factor Rated - 0.93 0.93 0.93 0.93
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL code RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037
Heat Exchanger Wide Louver Plus Wide Louver Plus Wide Louver Plus Wide Louver Plus
Compressor Motor Output x Number W x No. 5,300 x 3 5,300 x 3 5,300 x 3 5,300 x 3
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W (900 x 2) + (1,200 x 1) (900 x 2) + (1,200 x 1) 900 x 4 900 x 4
m3/min (320 x 1) + (240 x 1) (320 x 1) + (240 x 1) 320 x 2 320 x 2
Air Flow Rate (High)
Fan ft3/min (11,301 x 1) + (8,476 x 1) (11,301 x 1) + (8,476 x 1) 11,301 x 2 11,301 x 2
External Static Pressure (Max, Pa) 80 80 80 80
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) 19.05 (3/4) 19.05 (3/4) 19.05 (3/4) 19.05 (3/4)
Connections Gas Pipe mm (inch) 34.9 (1-3/8) 41.3 (1-5/8) 41.3 (1-5/8) 41.3 (1-5/8)
(1,240 x 1,690 x 760) x 1 (1,240 x 1,690 x 760) x 1
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 2 (1,240 x1,690 x 760) x 2
+ (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1
Net Weight kg (281 x 1) + (199 x 1) (283 x 1) + (199 x 1) (283 x 1) + (221 x 1) (283 x 1) + (221 x 1)
Sound Pressure Cooling dB(A) 65.6 66.0 66.2 66.3
Level Heating dB(A) 66.6 67.8 68.0 68.1
Sound Cooling dB(A) 86.8 88.5 89.0 89.2
Power Level Heating dB(A) 88.6 90.4 91.0 91.2
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A R410A R410A
Precharged Amount kg 14.0 + 10.0 16.0 + 10.0 16.0 + 13.0 16.0 + 13.0
Refrigerant in factory lbs 30.9 + 22.0 35.3 + 22.0 35.3 + 28.7 35.3 + 28.7
t-CO2eq 50.1 54.3 60.5 60.5
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Number of maximum connectable indoor units 55 (64) 58 (64) 61 (64) 64

Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design.
Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*1 Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
*2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination.
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)

060 / 061
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION

MULTI V 5 HEAT PUMP


ARUN420LTE5 / ARUN440LTE5
ARUN460LTE5 / ARUN480LTE5

HP 42 44 46 48
Combination Unit ARUN420LTE5 ARUN440LTE5 ARUN460LTE5 ARUN480LTE5
Model Name ARUN240LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
Independent Unit
ARUN180LTE5 ARUN200LTE5 ARUN220LTE5 ARUN240LTE5
kW 117.6 123.2 128.8 134.4
Cooling (Rated) Btu/h 401,300 420,400 439,500 458,600
Capacity Btu/h 403,600 423,100 442,500 461,600
kW 131.0 137.3 143.6 148.5
Heating (Rated)
Btu/h 446,900 468,400 489,900 506,800
Cooling (Rated) kW 27.71 29.07 31.60 33.52
Input
Heating (Rated) kW 30.91 34.36 36.39 37.69
COP Cooling (Rated) 4.24 4.24 4.08 4.01
COP Heating (Rated) 4.24 3.99 3.94 3.94
Power Factor Rated - 0.93 0.93 0.93 0.93
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL code RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037
Heat Exchanger Wide Louver Plus Wide Louver Plus Wide Louver Plus Wide Louver Plus
Compressor Motor Output x Number W x No. (5,300 x 3) + (4,200 x 1) 5,300 x 4 5,300 x 4 5,300 x 4
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W 900 x 4 900 x 4 900 x 4 900 x 4
m3/min 320 x 2 320 x 2 320 x 2 320 x 2
Air Flow Rate (High)
Fan ft3/min 11,301 x 2 11,301 x 2 11,301 x 2 11,301 x 2
External Static Pressure (Max, Pa) 80 80 80 80
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) 19.05 (3/4) 19.05 (3/4) 19.05 (3/4) 19.05 (3/4)
Connections Gas Pipe mm (inch) 41.3 (1-5/8) 41.3 (1-5/8) 41.3 (1-5/8) 41.3 (1-5/8)
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 2 (1,240 x1,690 x 760) x 2 (1,240 x1,690 x 760) x 2 (1,240 x1,690 x 760) x 2
Net Weight kg (283 x 1) + (261 x 1) (283 x 1) + (281 x 1) (283 x 1) + (281 x 1) 283 x 2
Sound Pressure Cooling dB(A) 66.5 66.8 67.8 68.0
Level Heating dB(A) 68.2 68.9 69.3 70.0
Sound Cooling dB(A) 89.8 90.1 90.1 91.0
Power Level Heating dB(A) 91.5 91.8 92.1 93.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A R410A R410A
Precharged Amount kg 16.0 + 13.0 16.0 + 14.0 16.0 + 14.0 16.0 + 16.0
Refrigerant in factory lbs 35.3 + 28.7 35.3 + 30.9 35.3 + 30.9 35.3 + 35.3
t-CO2eq 60.5 62.6 62.6 66.8
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Number of maximum connectable indoor units 64 64 64 64

Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design.
Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*1 Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
*2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination.
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
MULTI V 5 HEAT PUMP
ARUN500LTE5 / ARUN520LTE5
ARUN540LTE5 / ARUN560LTE5

HP 50 52 54 56
Combination Unit ARUN500LTE5 ARUN520LTE5 ARUN540LTE5 ARUN560LTE5
Model Name ARUN240LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
Independent Unit ARUN140LTE5 ARUN160LTE5 ARUN180LTE5 ARUN200LTE5
ARUN120LTE5 ARUN120LTE5 ARUN120LTE5 ARUN120LTE5
kW 140.0 145.6 151.2 156.8
Cooling (Rated) Btu/h*1 477,700 496,800 515,900 535,000
Capacity Btu/h*2 481,100 500,200 519,300 538,800
kW 156.2 162.5 168.8 175.1
Heating (Rated)
Btu/h 532,900 554,400 575,900 597,400
Cooling (Rated) kW 33.78 35.46 35.62 36.97
Input
Heating (Rated) kW 36.68 38.49 38.97 42.42
COP Cooling (Rated) 4.14 4.11 4.24 4.24
COP Heating (Rated) 4.26 4.22 4.33 4.13
Power Factor Rated - 0.93 0.93 0.93 0.93
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL code RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037
Heat Exchanger Wide Louver Plus Wide Louver Plus Wide Louver Plus Wide Louver Plus
Compressor Motor Output x Number W x No. 5,300 x 4 5,300 x 4 (5,300 x 4) + (4,200 x 1) 5,300 x 5
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W (900 x 4) + (1,200 x 1) (900 x 4) + (1,200 x 1) (900 x 4) + (1,200 x 1) (900 x 4) + (1,200 x 1)
m3/min (320 x 2) + (240 x 1) (320 x 2) + (240 x 1) (320 x 2) + (240 x 1) (320 x 2) + (240 x 1)
Air Flow Rate (High)
Fan ft3/min (11,301 x 2) + (8,476 x 1) (11,301 x 2) + (8,476 x 1) (11,301 x 2) + (8,476 x 1) (11,301 x 2) + (8,476 x 1)
External Static Pressure (Max, Pa) 80 80 80 80
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) 19.05 (3/4) 19.05 (3/4) 19.05 (3/4) 19.05 (3/4)
Connections Gas Pipe mm (inch) 41.3 (1-5/8) 41.3 (1-5/8) 41.3 (1-5/8) 41.3 (1-5/8)
(1,240 x 1,690 x 760) x 2 (1,240 x 1,690 x 760) x 2 (1,240 x 1,690 x 760) x 2 (1,240 x 1,690 x 760) x 2
Dimensions (W x H x D) mm x No.
+ (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1
Net Weight kg (283 x 1) + (221 x 1) + (199 x 1) (283 x 1) + (221 x 1) + (199 x 1) (283 x 1) + (261 x 1) + (199 x 1) (283 x 1) + (281 x 1) + (199 x 1)
Sound Pressure Cooling dB(A) 67.0 67.1 67.2 67.4
Level Heating dB(A) 68.6 68.7 68.8 69.5
Sound Cooling dB(A) 89.4 89.6 90.1 90.4
Power Level Heating dB(A) 91.3 91.5 91.8 92.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A R410A R410A
Precharged Amount kg 16.0 + 13.0 + 10.0 16.0 + 13.0 + 10.0 16.0 + 13.0 + 10.0 16.0 + 14.0 + 10.0
Refrigerant in factory lbs 35.3 + 28.7 + 22.0 35.3 + 28.7 + 22.0 35.3 + 28.7 + 22.0 35.3 + 30.9 + 22.0
t-CO2eq 81.4 81.4 81.4 83.5
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Number of maximum connectable indoor units 64 64 64 64

Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design.
Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*1 Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
*2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination.
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)

062 / 063
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION

MULTI V 5 HEAT PUMP


ARUN580LTE5 / ARUN600LTE5
ARUN620LTE5 / ARUN640LTE5

HP 58 60 62 64
Combination Unit ARUN580LTE5 ARUN600LTE5 ARUN620LTE5 ARUN640LTE5
Model Name ARUN240LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
Independent Unit ARUN220LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
ARUN120LTE5 ARUN120LTE5 ARUN140LTE5 ARUN160LTE5
kW 162.4 168.0 173.6 179.2
Cooling (Rated) Btu/h*1 554,100 573,200 592,400 611,500
Capacity Btu/h*2 557,900 577,300 595,700 614,800
kW 181.4 186.3 192.6 198.9
Heating (Rated)
Btu/h 618,900 635,800 657,300 678,800
Cooling (Rated) kW 39.51 41.42 42.63 44.31
Input
Heating (Rated) kW 44.45 45.75 47.47 49.28
COP Cooling (Rated) 4.11 4.06 4.07 4.04
COP Heating (Rated) 4.08 4.07 4.06 4.04
Power Factor Rated - 0.93 0.93 0.93 0.93
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL code RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037
Heat Exchanger Wide Louver Plus Wide Louver Plus Wide Louver Plus Wide Louver Plus
Compressor Motor Output x Number W x No. 5,300 x 5 5,300 x 5 5,300 x 5 5,300 x 5
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W (900 x 4) + (1,200 x 1) (900 x 4) + (1,200 x 1) 900 x 6 900 x 6
m3/min (320 x 2) + (240 x 1) (320 x 2) + (240 x 1) 320 x 3 320 x 3
Air Flow Rate (High)
Fan ft3/min (11,301 x 2) + (8,476 x 1) (11,301 x 2) + (8,476 x 1) 11,301 x 3 11,301 x 3
External Static Pressure (Max, Pa) 80 80 80 80
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) 19.05 (3/4) 19.05 (3/4) 22.2 (7/8) 22.2 (7/8)
Connections Gas Pipe mm (inch) 41.3 (1-5/8) 41.3 (1-5/8) 41.3 (1-5/8) 41.3 (1-5/8)
(1,240 x 1,690 x 760) x 2 (1,240 x 1,690 x 760) x 2
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 3 (1,240 x1,690 x 760) x 3
+ (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1
Net Weight kg (283 x 1) + (281 x 1) + (199 x 1) (283 x 2) + (199 x 1) (283 x 2) + (221 x 1) (283 x 2) + (221 x 1)
Sound Pressure Cooling dB(A) 68.3 68.5 68.6 68.7
Level Heating dB(A) 69.8 70.4 70.5 70.6
Sound Cooling dB(A) 90.4 91.3 91.5 91.6
Power Level Heating dB(A) 92.4 93.2 93.5 93.6
No. x mm2.
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A R410A R410A
Precharged Amount kg 16.0 + 14.0 + 10.0 16.0 + 16.0 + 10.0 16.0 + 16.0 + 13.0 16.0 + 16.0 + 13.0
Refrigerant in factory lbs 35.3 + 30.9 + 22.0 35.3 + 35.3 + 22.0 35.3 + 35.3 + 28.7 35.3 + 35.3 + 28.7
t-CO2eq 83.5 87.7 93.9 93.9
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Number of maximum connectable indoor units 64 64 64 64

Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design.
Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*1 Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
*2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination.
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
MULTI V 5 HEAT PUMP
ARUN660LTE5 / ARUN680LTE5
ARUN700LTE5 / ARUN720LTE5

HP 66 68 70 72
Combination Unit ARUN660LTE5 ARUN680LTE5 ARUN700LTE5 ARUN720LTE5
Model Name ARUN240LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
Independent Unit ARUN240LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
ARUN180LTE5 ARUN200LTE5 ARUN220LTE5 ARUN240LTE5
kW 184.8 190.4 196.0 201.6
Cooling (Rated) Btu/h*1 630,600 649,700 668,800 687,900
Capacity Btu/h*2 634,300 653,700 673,200 692,300
kW 205.2 211.5 217.8 222.8
Heating (Rated)
Btu/h 700,300 721,800 743,300 760,200
Cooling (Rated) kW 44.47 45.82 48.36 50.27
Input
Heating (Rated) kW 49.76 53.21 55.24 56.54
COP Cooling (Rated) 4.16 4.16 4.05 4.01
COP Heating (Rated) 4.12 3.97 3.94 3.94
Power Factor Rated - 0.93 0.93 0.93 0.93
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL code RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037
Heat Exchanger Wide Louver Plus Wide Louver Plus Wide Louver Plus Wide Louver Plus
Compressor Motor Output x Number W x No. (5,300 x 5) + (4,200 x 1) 5,300 x 6 5,300 x 6 5,300 x 6
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W 900 x 6 900 x 6 900 x 6 900 x 6
m3/min 320 x 3 320 x 3 320 x 3 320 x 3
Air Flow Rate (High)
Fan ft3/min 11,301 x 3 11,301 x 3 11,301 x 3 11,301 x 3
External Static Pressure (Max, Pa) 80 80 80 80
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) 22.2 (7/8) 22.2 (7/8) 22.2 (7/8) 22.2 (7/8)
Connections Gas Pipe mm (inch) 53.98 (2-1/8) 53.98 (2-1/8) 53.98 (2-1/8) 53.98 (2-1/8)
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 3 (1,240 x1,690 x 760) x 3 (1,240 x1,690 x 760) x 3 (1,240 x1,690 x 760) x 3
Net Weight kg (283 x 2) + (261 x 1) (283 x 2) + (281 x 1) (283 x 2) + (281 x 1) 283 x 3
Sound Pressure Cooling dB(A) 68.8 69.0 69.6 69.8
Level Heating dB(A) 70.6 71.1 71.3 71.8
Sound Cooling dB(A) 92.0 92.2 92.2 92.8
Power Level Heating dB(A) 93.8 94.0 94.2 94.8
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A R410A R410A
Precharged Amount kg 16.0 + 16.0 + 13.0 16.0 + 16.0 + 14.0 16.0 + 16.0 + 14.0 16.0 + 16.0 + 16.0
Refrigerant in factory lbs 35.3 + 35.3 + 28.7 35.3 + 35.3 + 30.9 35.3 + 35.3 + 30.9 35.3 + 35.3 + 35.3
t-CO2eq 93.9 96.0 96.0 100.2
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Number of maximum connectable indoor units 64 64 64 64

Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design.
Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*1 Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
*2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination.
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)

064 / 065
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION

MULTI V 5 HEAT PUMP


ARUN740LTE5 / ARUN760LTE5
ARUN780LTE5 / ARUN800LTE5

HP 74 76 78 80
Combination Unit ARUN740LTE5 ARUN760LTE5 ARUN780LTE5 ARUN800LTE5
ARUN240LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
Model Name ARUN240LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
Independent Unit
ARUN140LTE5 ARUN160LTE5 ARUN180LTE5 ARUN200LTE5
ARUN120LTE5 ARUN120LTE5 ARUN120LTE5 ARUN120LTE5
kW 207.2 212.8 218.4 224.0
Cooling (Rated) Btu/h*1 707,000 726,100 745,200 764,300
Capacity Btu/h*2 711,700 730,900 759,300 769,700
kW 230.4 236.7 243.0 249.3
Heating (Rated)
Btu/h 786,300 807,800 829,300 850,800
Cooling (Rated) kW 50.54 52.22 52.38 53.73
Input
Heating (Rated) kW 55.53 57.34 57.82 61.27
COP Cooling (Rated) 4.10 4.08 4.17 4.17
COP Heating (Rated) 4.15 4.13 4.20 4.07
Power Factor Rated - 0.93 0.93 0.93 0.93
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL code RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037
Heat Exchanger Wide Louver Plus Wide Louver Plus Wide Louver Plus Wide Louver Plus
Compressor Motor Output x Number W x No. 5,300 x 6 5,300 x 6 (5,300 x 6) + (4,200 x 1) 5,300 x 7
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W (900 x 6) + (1,200 x 1) (900 x 6) + (1,200 x 1) (900 x 6) + (1,200 x 1) (900 x 6) + (1,200 x 1)
m3/min (320 x 3) + (240 x 1) (320 x 3) + (240 x 1) (320 x 3) + (240 x 1) (320 x 3) + (240 x 1)
Air Flow Rate (High)
Fan ft3/min (11,301 x 3) + (8,476 x 1) (11,301 x 3) + (8,476 x 1) (11,301 x 3) + (8,476 x 1) (11,301 x 3) + (8,476 x 1)
External Static Pressure (Max, Pa) 80 80 80 80
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) 22.2 (7/8) 22.2 (7/8) 22.2 (7/8) 22.2 (7/8)
Connections Gas Pipe mm (inch) 53.98 (2-1/8) 53.98 (2-1/8) 53.98 (2-1/8) 53.98 (2-1/8)
(1,240 x 1,690 x 760) x 3 (1,240 x 1,690 x 760) x 3 (1,240 x 1,690 x 760) x 3 (1,240 x 1,690 x 760) x 3
Dimensions (W x H x D) mm x No.
+ (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1
Net Weight kg (283 x 2) + (221 x 1) + (199 x 1) (283 x 2) + (221 x 1) + (199 x 1) (283 x 2) + (261 x 1) + (199 x 1) (283 x 2) + (281 x 1) + (199 x 1)
Sound Pressure Cooling dB(A) 69.1 69.2 69.2 69.4
Level Heating dB(A) 70.9 70.9 71.0 71.4
Sound Cooling dB(A) 91.8 91.9 92.2 92.4
Power Level Heating dB(A) 93.7 93.8 94.0 94.2
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A R410A R410A
Precharged Amount kg 16.0 + 16.0 + 13.0 + 10.0 16.0 + 16.0 + 13.0 + 10.0 16.0 + 16.0 + 13.0 + 10.0 16.0 + 16.0 + 14.0 + 10.0
Refrigerant in factory lbs 35.3 + 35.3 + 28.7 + 22.0 35.3 + 35.3 + 28.7 + 22.0 35.3 + 35.3 + 28.7 + 22.0 35.3 + 35.3 + 30.9 + 22.0
t-CO2eq 114.8 114.8 114.8 116.9
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Number of maximum connectable indoor units 64 64 64 64

Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design.
Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*1 Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
*2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination.
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
MULTI V 5 HEAT PUMP
ARUN820LTE5 / ARUN840LTE5
ARUN860LTE5 / ARUN880LTE5

HP 82 84 86 88
Combination Unit ARUN820LTE5 ARUN840LTE5 ARUN860LTE5 ARUN880LTE5
ARUN240LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
Model Name ARUN240LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
Independent Unit
ARUN220LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
ARUN120LTE5 ARUN120LTE5 ARUN140LTE5 ARUN160LTE5
kW 229.6 235.2 240.8 246.4
Cooling (Rated) Btu/h*1 783,400 802,500 821,700 840,800
Capacity Btu/h*2 788,200 807,400 826,500 846,800
kW 255.6 260.6 266.9 273.2
Heating (Rated)
Btu/h 872,300 889,200 910,700 932,200
Cooling (Rated) kW 56.27 58.18 59.39 61.07
Input
Heating (Rated) kW 63.30 64.60 66.32 68.13
COP Cooling (Rated) 4.08 4.04 4.05 4.03
COP Heating (Rated) 4.04 4.03 4.02 4.01
Power Factor Rated - 0.93 0.93 0.93 0.93
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL code RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037
Heat Exchanger Wide Louver Plus Wide Louver Plus Wide Louver Plus Wide Louver Plus
Compressor Motor Output x Number W x No. 5,300 x 7 5,300 x 7 5,300 x 7 5,300 x 7
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W (900 x 6) + (1,200 x 1) (900 x 6) + (1,200 x 1) 900 x 8 900 x 8
m3/min (320 x 3) + (240 x 1) (320 x 3) + (240 x 1) 320 x 4 320 x 4
Air Flow Rate (High)
Fan ft3/min (11,301 x 3) + (8,476 x 1) (11,301 x 3) + (8,476 x 1) 11,301 x 4 11,301 x 4
External Static Pressure (Max, Pa) 80 80 80 80
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) 22.2 (7/8) 22.2 (7/8) 22.2 (7/8) 22.2 (7/8)
Connections Gas Pipe mm (inch) 53.98 (2-1/8) 53.98 (2-1/8) 53.98 (2-1/8) 53.98 (2-1/8)
(1,240 x 1,690 x 760) x 3 (1,240 x 1,690 x 760) x 3
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 4 (1,240 x1,690 x 760) x 4
+ (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1
Net Weight kg (283 x 2) + (281 x 1) + (199 x 1) (283 x 3) + (199 x 1) (283 x 3) + (221 x 1) (283 x 3) + (221 x 1)
Sound Pressure Cooling dB(A) 70.0 70.1 70.2 70.3
Level Heating dB(A) 71.6 72.1 72.1 72.2
Sound Cooling dB(A) 92.4 92.9 93.1 93.2
Power Level Heating dB(A) 94.4 94.9 95.1 95.2
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A R410A R410A
Precharged Amount kg 16.0 + 16.0 + 14.0 + 10.0 16.0 + 16.0 + 16.0 + 10.0 16.0 + 16.0 + 16.0 + 13.0 16.0 + 16.0 + 16.0 + 13.0
Refrigerant in factory lbs 35.3 + 35.3 + 30.9 + 22.0 35.3 + 35.3 + 35.3 + 22.0 35.3 + 35.3 + 35.3 + 28.7 35.3 + 35.3 + 35.3 + 28.7
t-CO2eq 116.9 121.1 127.3 127.3
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Number of maximum connectable indoor units 64 64 64 64

Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design.
Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*1 Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
*2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination.
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)

066 / 067
OUTDOOR UNITS _ MULTI V 5 _ SPECIFICATION

MULTI V 5 HEAT PUMP


ARUN900LTE5 / ARUN920LTE5
ARUN940LTE5 / ARUN960LTE5

HP 90 92 94 96
Combination Unit ARUN900LTE5 ARUN920LTE5 ARUN940LTE5 ARUN960LTE5
ARUN240LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
Model Name ARUN240LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
Independent Unit
ARUN240LTE5 ARUN240LTE5 ARUN240LTE5 ARUN240LTE5
ARUN180LTE5 ARUN200LTE5 ARUN220LTE5 ARUN240LTE5
kW 252.0 257.6 263.2 268.8
Cooling (Rated) Btu/h*1 859,900 879,000 898,100 917,200
Capacity Btu/h*2 865,100 884,500 903,600 922,800
kW 279.5 285.8 292.1 297.0
Heating (Rated)
Btu/h 953,700 975,200 996,700 1,013,600
Cooling (Rated) kW 61.23 62.58 65.12 67.03
Input
Heating (Rated) kW 68.60 72.06 74.08 75.39
COP Cooling (Rated) 4.12 4.12 4.04 4.01
COP Heating (Rated) 4.07 3.97 3.94 3.94
Power Factor Rated - 0.93 0.93 0.93 0.93
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL code RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037
Heat Exchanger Wide Louver Plus Wide Louver Plus Wide Louver Plus Wide Louver Plus
Compressor Motor Output x Number W x No. (5,300 x 7) + (4,200 x 1) 5,300 x 8 5,300 x 8 5,300 x 8
Type Propeller fan Propeller fan Propeller fan Propeller fan
Motor Output x Number W 900 x 8 900 x 8 900 x 8 900 x 8
m3/min 320 x 4 320 x 4 320 x 4 320 x 4
Air Flow Rate (High)
Fan ft3/min 11,301 x 4 11,301 x 4 11,301 x 4 11,301 x 4
External Static Pressure (Max, Pa) 80 80 80 80
Drive DC INVERTER DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP TOP
Pipe Liquid Pipe mm (inch) 22.2 (7/8) 22.2 (7/8) 22.2 (7/8) 22.2 (7/8)
Connections Gas Pipe mm (inch) 53.98 (2-1/8) 53.98 (2-1/8) 53.98 (2-1/8) 53.98 (2-1/8)
Dimensions (W x H x D) mm x No. (1,240 x1,690 x 760) x 4 (1,240 x1,690 x 760) x 4 (1,240 x1,690 x 760) x 4 (1,240 x1,690 x 760) x 4
Net Weight kg (283 x 3) + (261 x 1) (283 x 3) + (281 x 1) (283 x 3) + (281 x 1) (283 x 4)
Sound Pressure Cooling dB(A) 70.3 70.4 70.9 71.0
Level Heating dB(A) 72.2 72.5 72.7 73.0
Sound Cooling dB(A) 93.4 93.6 93.6 94.0
Power Level Heating dB(A) 95.3 95.4 95.6 96.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A R410A R410A
Precharged Amount kg 16.0 + 16.0 + 16.0 + 13.0 16.0 + 16.0 + 16.0 + 14.0 16.0 + 16.0 + 16.0 + 14.0 16.0 + 16.0 + 16.0 + 16.0
Refrigerant in factory lbs 35.3 + 35.3 + 35.3 + 28.7 35.3 + 35.3 + 35.3 + 30.9 35.3 + 35.3 + 35.3 + 30.9 35.3 + 35.3 + 35.3 + 35.3
t-CO2eq 127.3 129.4 129.4 133.6
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380-415, 50 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60 3, 380, 60
Number of maximum connectable indoor units 64 64 64 64

Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design.
Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*1 Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
*2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination.
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
MULTI V 5 HEAT PUMP
ARUN221LTE5 / ARUN241LTE5
ARUN261LTE5

HP 22' 24' 26'


Combination Unit ARUN221LTE5 ARUN241LTE5 ARUN261LTE5
Model Name ARUN120LTE5 ARUN120LTE5 ARUN140LTE5
Independent Unit
ARUN100LTE5 ARUN120LTE5 ARUN120LTE5
kW 61.6 67.2 72.8
Cooling (Rated) Btu/h*1 210,200 229,300 248,400
Capacity Btu/h*2 211,500 230,700 249,800
kW 69.3 75.6 81.9
Heating (Rated)
Btu/h 236,500 258,000 279,500
Cooling (Rated) kW 13.6 15.81 17.02
Input
Heating (Rated) kW 13.8 16.12 17.84
COP Cooling (Rated) 4.53 4.25 4.28
COP Heating (Rated) 5.02 4.69 4.59
Power Factor Rated - 4.78 5.03 4.81
Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray Morning Gray / Dawn Gray
Exterior
RAL code RAL 7030 / RAL 7037 RAL 7030 / RAL 7037 RAL 7030 / RAL 7037
Heat Exchanger Wide Louver Plus Wide Louver Plus Wide Louver Plus
Compressor Motor Output x Number W x No. 5,300 x 2 (5,300 x 2) + (4,200 x 1) (5,300 x 2) + (4,200 x 1)
Type Propeller fan Propeller fan Propeller fan
Motor Output x Number W (1,200 x 1) + (1,200 x1) (1,200 x 1) + (1,200 x1) (900 x 2) + (1,200 x1)
m3/min (240 x 1) + (240 x 1) (240 x 1) + (240 x 1) (320 x 1) + (240 x 1)
Air Flow Rate (High)
Fan ft3/min (8,476 x 1) + (8,476 x 1) (8,476 x 1) + (8,476 x 1) (11,301 x 1) + (8,476 x 1)
External Static Pressure (Max, Pa) 80 80 80
Drive DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP TOP
Pipe Liquid Pipe mm (inch) 15.88 (5/8) 15.88 (5/8) 19.05 (3/4)
Connections Gas Pipe mm (inch) 28.58 (1-1/8) 34.9 (1-3/8) 34.9 (1-3/8)
(930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1 (930 x 1,690 x 760) x 1
Dimensions (W x H x D) mm x No.
+ (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1 + (930 x 1,690 x 760) x 1
Net Weight kg (199 x 1) + (199 x 1) (199 x 1) + (199 x 1) (221 x 1) + (199 x 1)
Sound Pressure Cooling dB(A) 61.5 62.0 62.5
Level Heating dB(A) 62.5 63.0 63.5
Sound Cooling dB(A) 81.5 82.0 83.8
Power Level Heating dB(A) 82.5 83.0 85.5
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A R410A
Precharged Amount
kg 10.0 + 10.0 10.0 + 10.0 13.0 + 10.0
Refrigerant in factory
t-CO2eq 39.7 39.7 48.01
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Power Supply Ø, V, Hz
3, 380, 60 3, 380, 60 3, 380, 60
Number of maximum connectable indoor units 35 (44) 39 (48) 42 (52)

Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design.
Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than �1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*1 Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
*2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination.
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)

068 / 069
- Air cooled VRF Heat pump & Heat Recovery
- 9.2 ~ 33.6kW (Cooling capacity based)
- Both 1Ø, 220 ~ 240V, 50Hz and 3Ø, 380 ~ 415V, 50Hz
- Side discharge outdoor unit
- Includes the industry’s first single phase Heat Recovery system

TOTAL PIPING LENGTH

Compact yet
powerful VRF
For premium
residences and
small offices
300m 150m (175m)
TOTAL PIPING LENGTH Longest piping length
* ARUV series : 80-100m (Depends on model) from ODU ~ IDU (Equivalent)
* ARUV series : 40-50m (Depends

Piping Capabilities on model)

Total Piping Length 300m


Longest piping length 150m
(Equivalent) (175m)
Longest piping length after 1st branch 40m
(Conditional application) (90m)
Height difference between 40m*
ODU ~ IDU (50m**)
Height difference between IDU ~ IDU 15m
* In case of outdoor unit installed lower than indoor unit
** In case of outdoor unit installed upper than indoor unit between ODU ~ IDU
* ARUV series : 15m
Height Difference
50m

between IDU ~ IDU


* ARUV series : 7.5m
Height Difference
15m
※ Only applies to MULTI V S with R410A refrigerant

How does it work?


Available in Heat Pump and
Heat Recovery Configurations

Energy savings Energy saving by heat


recovery unit

Combination of Cooling,
Heating and Hot Water Solution
Reliability

INDOOR UNIT

HYDRO KIT
MULTI V S
Heat Recovery
Convenience ※ Heat Pump and Recovery are separated models.

070 / 071
OUTDOOR UNITS _ MULTI V S _ KEY FEATURES

ENERGY SAVINGS
EER / COP / Part Load Inverter Twin Rotary &
Cost savings with energy efficiency Inverter Scroll Compressor
Heat Pump Adapted High Efficient Compressor according to Capacity
EER (Cooling) COP (Heating) Inverter Twin Rotary (12.1kW Inverter scroll compressor
~ 15.5kW) (22.4kW ~ 33.6kW)
Compressor Efficiency Comparison
43%

Efficiency
Scroll Compressor
16%
3.35 3.90 3.71 5.30 Rotary Compressor

Conventional MULTI V S HR Conventional MULTI V S HR


(MULTI V S H/P) (MULTI V S H/P) 12.1 19.6 28 kW
(Cooling capacity)
※ Comparison Based on 15.5kW in cooling mode ※ Comparison Based on 15.5kW in heating mode � Based on internal test data

Heat Recovery Inverter Twin Rotary


Cooling Mode Heating Mode Concentrated Winding Motor
Oil path area is improved by over 50% by increasing the extra stator cavity. Due to this, caloric value
Cooling EER is 5% higher than conventional Heating COP is 5% higher than conventional
on average. on average. of motor is reduced, improving the cooling function of stator coil.

Twin Rotary Rotor


Upper and lower part rotor offset imbalance in shaft rotor rotation. Vibration and noise is reduced.
5% 3.90
5% 4.39
Max torque load decreased by 45% compared to single rotor.
4.18
3.71
Surface Coating
Surface coating of outstanding abrasion resistance property on vane and crank shaft.
Conventional MULTI V S HR Conventional MULTI V S HR
(MULTI V S H/P) (MULTI V S H/P)
※ Comparison Based on 15.5kW in cooling mode ※ Comparison Based on 15.5kW in heating mode Inverter scroll compressor

Operation Range (Hz)


Best-in-class Compressor Speed 150

Smart Load Control Applied - Rapid response capability


- Compact core design (Concentrated motor)
120

20
Enhanced comfort and up to 23% energy savings with MULTI V load - Down to 15Hz : Part load efficiency improvement 15
Conventional
control 6 Bypass Valve
Compressor reliability is maximized with 6 Bypass Valve
MULTI V S changes indoor discharge air temperature continuously according to load, - Prevent compressor damage due to excessively compressed refrigerant more efficiently than
to save energy. 4 Bypass valve

SLC (Smart Load Control) operation Direct Oil Injection


Startup Operation Real Time Operation ... - Eliminate suction refrigerant gas heat loss through direct oil injection into compression chamber
(Efficiency increases)
- Increased reliability with regulated oil supply
Startup After 20 minutes

Startup Operation Scroll Profile


- The enhanced reliability by Increased reliability with regulated oil supply.
Basic Operation Smart Load Control - Efficiency increases by expanding 96% Bypass area and 17% improved volume ratio by non-uniform scroll thickness
Indoor
Discharge Air
Temperature

Power
Input
Optimal Heat Exchanger
Maximize Efficiency according to different Heat Exchanger path by
※ Indoor air discharge temperature
Until 20 minutes after startup operation cooling and heating
- Energy efficiency increased by 3-step Smart Load Control during startup phase
- Discharge air temperature adjusted according to outdoor and indoor temperature
- Comfort level in cooling / heating operations ensured
Variable Heat Exchanger Circuit intelligently selects the optimal path for both
heating and cooling operations. With this smart path selection technology, an
Max.10% Energy saving average of 6% increase in the efficiency of both operations has been achieved.
The paths number and circuit velocity are adjusted to match temperatures
Real Time Operation and operation modes in order to maximize efficiency instead of compromising
Basic Operation Smart Load Control
efficiency for each operation when the number and direction of paths are fixed
3°C 10°C independently of temperature operation mode.
Refrigerant Refrigerant

20°C 20°C

3°C 3°C
Refrigerant Refrigerant
Fixed heat
35°C 35°C exchanger circuit
Cooling Heating

Fixed refrigerant temperature Variable refrigerant temperature Efficiency performance Efficiency up due to Fin shape
Efficiency
Max. 13% Energy saving Improved heat exchanger efficiency of up to 28%
Conventional Wide Louver Plus Fin
※ How to set up : By dip switch in outdoor unit (Referred to Product Data Book) Factory default setting is Off. Heating
※ ESEER (European seasonal energy efficiency Ratio) conditions based on 15.5kW unit Cooling 100% Cooling 128%
- Outdoor temperature condition :
EER 100% / 75% / 50% / 25% = 35°C (DB) / 30°C (DB) / 25°C (DB) / 20°C (DB) Cooling
- Indoor temperature condition : 27°C (DB) / 19°C (WB) Heating 100% Heating 123%
※ Dual sensing (Temperature & humidity) Smart Load Control is possible with Remote controller Previous Design (Fixed) Number of
PTEMTB100 (White) /PREMTBB10 (Black) circuit
RELIABILITY
Reliable Refrigerant Components
LG technology allows for superior performance and component durability

Refrigerant
❶ Cyclonic oil separator Refrigerant
+ Oil
- Highly reliable and efficient oil separation by
centrifuge using cyclonic methods Cyclone
Centrifuges
- High collection efficiency as well as outstanding resistance to high
Oil
temperature and pressure Oil Separator

❷ Large Volume Accumulator


- Improved reliability by adopting the large volume accumulator
(38% volume up compared to conventional) Accumulator
- Prevents the liquid refrigerant entering the compressor suction
- Maximize efficiency by optimal amount of refrigerant
- Protects compressor breakdown to increase product lifetime

40% 20%
❸ BLDC Fan Motor

Efficiency (%)
100
BLDC
Motor
- The BLDC Fan motor is more efficient than a conventional AC motor,

50
offering an additional 40% energy savings AC Motor
at low speeds and 20% at high speeds
500 1,000
Motor Speed (RPM)

❹ Double Sub-cool Interchanger


- Reliability is enhanced by minimizing pressure drop due to high efficiency spiral
MULTI V S improved reliability with advanced technology :
structure and 2 times larger size
- Oil separator Long pipe is possible (up to* 175m) and high elevation (up to* 50m)
- Accumulator Reduction of indoor refrigerant noise level
- Sub-cooling * Based on equivalent pipe length Double Sub-cool Interchanger

Smart Control Corrosion Resistance Proven by Certified Tests


Pressure control applied for smart, quick and precise response to user's LG Corrosion Resistance solution passed ISO 21207 accelerated
temperature request corrosion test conducted by an independent test organization and the result has been
certified by prestigious global certification organization, TUV.
Temperature + Pressure Control
Senses and controls pressure directly using
pressure sensor for faster and more exact response Certified protection
to load variation.

High Pressure Low Pressure


Sensor Sensor

Quick Operating Response Outlet Temp (°C)

Desired temperature can be reached 27

up to 14% faster in cooling mode with 14%


Quicker
pressure control, allowing more accurate ※ Verification of corrosion resistance performance
12 - Declared by TUV Rheinland
control of indoor environment for - Test Method B of ISO21207
maximized comfort. 14% - Test condition : Salt contaminated condition
+ severe industrial /
2min Time traffic environment (NO2 / SO2)
Pressure + Temperature Control
Temperature Control
※ Specifications may vary for each model.
Enhanced Coating Layers
The black coating with enhanced epoxy resin is applied for strong protection
from various corrosive external conditions such as salt contamination and air
Corrosion Resistance Black Fin pollution. Moreover, the hydrophilic film keeps water from accumulating on the
Strong Durability against high salinity and heavily polluted air heat exchanger’s fin, minimizing moisture buildup and eventually making it even more
corrosion resistant.
Ocean Black Fin ensures continued operation of MULTI V S in highly corrosive environments
like salt concentration in coastal towns or severe air pollution in industrial cities keeps. This Hydrophilic film (Water flow)
The Hydrophilic coating minimizes moisture buildup on the fin.
improvement in durability prolongs the product’s lifespan and lowers both the operational and
maintenance costs. Acryl + Epoxy + Melamine resin (Corrosion resistant)
The Black coating provides strong protection from corrosion.

Aluminum fin

072 / 073
OUTDOOR UNITS _ MULTI V S _ KEY FEATURES

IMPROVED USER CONVENIENCE


Sufficient Piping Length Fan Technology and RPM Control
Increased piping length allows for flexible design and External static pressure control for outdoor unit fan to adapt
installation more flexibly to various installation conditions of outdoor unit

MULTI V S inverter technology and sub cooling control circuit technology allows For enhanced efficiency, new axial fan boasts higher air volume, increased static pressure
greater piping length and outstanding elevation differences. A cooling system can be and decreased noise.
implemented more flexibly in a shop, office and even high-rise building, reducing the
designer’s work time and providing more efficient design.
Fan Technology
The new axial fan has a mogul trailing edge, narrow hub blade and reverse hub, this provides a
high efficiency, low noise, wide fan, as well as improving the air flow rate.
Piping Capabilities (ARUN series)

Reverse
300m Mogul hub
Total piping length trailing edge

50m 526mm
ODU ~ IDU
Height Narrow
150m (175m) difference (1Ø) 5 / 6HP
hub blade
(1Ø) 4 / 5HP
Longest (3Ø) 4 / 5 / 6 / 8HP
pipe length
(Equivalent) 15m
IDU ~ IDU Super cannon fan increases the air volume in 50 CMM and the noise level is decreased by 4dB(A).
Height
difference
Grooved
suction surface

Tip vortex
suppressor

4 Way Piping Super Canon Fan


(3Ø) 10 / 12HP
- Free design and installation by 4 way piping.

Fan RPM control


Flow of air is straight due to fan shroud and Fan RPM control even in high-rise building.

Fan RPM
control
+ + (Fan Max RPM
Up)

Fan Shroud

• Straight air flow


Low Noise Operation - New shroud adopted
- Performs high static pressure
Decreased noise during operation with low noise functionality

At night mode, noise reduced maximum 14% compared to normal mode.


Upgraded Fault Detection and Diagnosis
Capacity Easy and convenient maintenance with self-diagnosis
Load
The inclusion of FDD elements - Auto start-up, auto refrigerant check,
black box functionality, simultaneous evaluation, and auto refrigerant collection,
Sound Level
provides the optimal solution for user reliability and ease of maintenance.
58 Night
Mode Start Mode End
56 Step 1
53 Step 2
- Auto commissioning Mode
50 Step 3
- Auto Refrigerant Collection
8:00 12:00 16:00 20:00 0:00 4:00 8:00 12:00 16:00
- Auto evaluation of refrigerant amount and
Time
charging FDD
Max. - Able to access LGMV (LG Monitoring View) by MICOM
58 8dB(A) smartphone
- Black box function
- Piping & wiring error check-up
50
※ Normal mode noise level (28kW) : 58dB(A)
50dB(A) ※ Night 3 step noise level (28kW) :
56dB(A),53dB(A), 50dB(A)
※ Sound pressure tested by following conditions :
Day Night 1m distance / 1.5m height
OUTDOOR UNIT _ MULTI V S _ TECHNICAL DATA

[Unit : mm] Symbols


Nomenclature A Piping Direction
165 620
A Datum Iine
ARU N 100 L S S 0 Piping
Direction

390
360
Serial number
Model Type
S : Standard 4 holes for Anchor Bolts (M10)
L : Compact C A
330 (34) 26 950
Air Discharge Type C
(7) 81 26 97 82 244
S : Side Discharge
Electrical Ratings 5 5
L : 3Ø, 380-415V, 50Hz
5 5
G : 1Ø, 220-240V, 50Hz

834
Total Cooling Capacity in Horse Power(HP) unit

660
627
EX) 8HP → '080', 10HP → '100' 3

466
476
Combination of Inverter Type and Cooling Only or Heat

24

141
Pump B B B

83
N : Inverter and H/P, V : Inverter and C/O 51 148
1 64
2 4
MULTI V System Outdoor Unit using R410A 416
40

111
291
276
Outdoor Units Function 5-1.D. Ø20 holes for drain connection 91
250 696
Category Functions MULTI V S
A
Variable Path of Outdoor Unit HEX -
HiPORTM (High Pressure Oil Return) -
Key Refrigerant Com-
Humidity Sensor -
ponents
Corrosion Resistance Black Fin ○
Oil Sensor -
Dual Sensing -
3D View
Low Noise Operation ○
Hgih Static Mode of Outdoor Unit Fan ○
[Unit : mm] Piping
620
Partial Defrosting - Direction

Auto Dust Removal of Outdoor Unit

14
Special Function -

390
360
(Fan reverse rotation)
Indoor Cooling Comfort Mode Based

Outdoor Temperature C A
Smart Load Control (SLC) 4 holes for Anchor Bolts (M10)
(Changingindoordischargeairtemperature ○
according to load) C
A 950
330 26
Outdoor Unit Control Refer to Humidity ARUB060GSS4 only 90
C
Defrost / Deicing ○
High Pressure Switch ○
Phase Protection ○
5
1380

Basic Function Restart Delay (3-minutes) ○


Self Diagnosis ○ 2
606

Soft Start ○ 80

Test Run Function - 80


52
25
AC Ez (Simple Controller) PQCSZ250S0 26
52

B 1 6 96 B 96
7
AC Ez Touch PACEZA000 695
416
AC Smart IV PACS4B000 250
91
Central Controller AC Smart 5 PACS5A000 40 164

ACP (Advanced Control Platform) IV PACP4B000


111
291
276

ACP (Advanced Control Platform) 5 PACP5A000 5-1.D. Ø


20 holes for drain connection
AC Manager 5 PACM5A000

BNU (Building Network ACP Lonworks PLNWKB000 75


A
Unit) ACP BACnet PQNFB17C0
60
44

IO Module (ODU Dry Contact) PVDSMN000


42

PDI (Power Distribution Standard PPWRDB000 91

Indicator) 4
Premium PQNUD1S40
3
Cool / Heat Selector PRDSBM
606

536
557

LGMV PRCTIL0
Cycle Monitoring Device
85

Mobile LGMV PLGMVW100


24

52

B 25 8 81
Refrigerant Charging Kit (Logical operation) Not 3D View
applied to ARUB060GSS4 Piping connection port
94
Additional kit
Low Ambient Kit -
Variable Water Flow Valve Control Kit - Note No. Part Name Description
1. Unit should be installed in compliance with the installation 1 Air Outlet -
manual in the product box. 2 Power and communication cable Hole -
3 Gas Pipe Connection Welding joint
2. Unit should be grounded in accordance with the local 4 Liquid Pipe Connection Welding joint
※ ○ : Applied, - : Not Applied regulation or applicable national codes. 5 Handle -
3. All electrical components and materials to be supplied 6 Pipe routing hole (front) -
from the site must comply with the local regulations or 7 Pipe routing hole (side) -
8 Pipe routing hole (back) -
international codes.
4. Electrical characteristics chapter should be considered for
electrical work and design. Especially the power cable and
circuit breaker should be selected in accordance with that.

074 / 075
OUTDOOR UNITS _ MULTI V S _ SPECIFICATION

MULTI V S COOLING ONLY


ARUV050GSD5 / ARUV060GSD5

HP 5 6
Model Name Combination Unit   ARUV050GSD5 ARUV060GSD5
kW 14.5 16.0
Cooling
Btu/h 49,500 54,600
Capacity (Rated)
kW - -
Heating
Btu/h - -
Cooling kW 3.62 4.50
Input (Rated)
Heating kW - -
COP Cooling (Rated) 0.93 0.93
COP (Rated) - -
Power Factor Rated - 1 1
Casing Color Warm Gray + RAL 7044 Warm Gray + RAL 7044
Heat Exchanger Wide Louver Plus Wide Louver Plus
Type LG Inverter Scroll LG Inverter Scroll
Piston Displacement cm3/rev 31.6 31.6
Number of Revolution rev/min
Compressor Motor Output x Number W x No. 3,198 x 1 3,198 x 1
Starting Method DC Inverter Starting DC Inverter Starting
Oil Type FW68D FW68D
Oil Charge 1,100 1,100
Type Axial Flow Fan Axial Flow Fan
Motor Output x Number W 198 x 1 198 x 1
m3/min 80 80
Fan Air Flow Rate (High)
ft3/min 2,825 2,825
Drive DC INVERTER DC INVERTER
Discharge Side / Top Side Side
Liquid  mm (inch) 9.52 (3/8) 9.52 (3/8)
Pipe Connections
Gas mm (inch) 15.88 (5/8) 19.05 (3/4)
mm 950 x 834 x 330 950 x 834 x 330
Dimensions (W x H x D)
inch 37-13/32 x 32-27/32 x 13 37-13/32 x 32-27/32 x 13
Net Weight kg 67 67
Cooling dB(A) 53 56
Sound Pressure Level
Heating dB(A) - -
Sound Power Level dB(A) - -
High pressure protection - Low pressure sensor Low pressure sensor
Over-heat protection /
Protection Devices Compressor / Fan - Over-heat protection / Fan driver overload protector
Fan driver overload protector
Inverter - Over-heat protection / Over-current protection Over-heat protection / Over-current protection
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A
kg 2.0 2.0
Refrigerant Precharged Amount
lbs 4.4 4.4
Control Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50
Number of maximum connectable indoor units 8 9

Note
1. Eurovent Test Condition : Type of indoor unit connected is only Ceiling Concealed Duct.
- Refer to EUROVENT certification regulation for more detail test conditions.
- Refer to EUROVENT website for test values connected Ceiling Cassette type indoors.
2. Performances are based on the following conditions :
- Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
- Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
3. The maximum combination ratio is 160%. (the maximum combination ratio of ARUN050GSL0 is 130%.)
4. Wiring cable size must comply with the applicable local and national codes.
5. Due to our policy of innovation some specifications may be changed without notification.
6. Sound pressure level is measured on the rated condition in the anechoic rooms byISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms byISO 3741 standard.Therefore, these
values can be increased owing to ambient conditions during operation.
7. Power factor could vary less than ±1% according to the operating conditions.
8. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
MULTI V S HEAT PUMP
ARUN050GSS5 / ARUN060GSS5

HP 5 6
Model Name Combination Unit ARUN050GSS5 ARUN060GSS5
kW 14.0 15.5
Cooling Btu/h*1 47,800 52,900
Capacity (Rated) Btu/h*2 49,500 54,800
kW 16.0 18.0
Heating
Btu/h 54,600 61,400
Cooling kW 3.33 3.97
Input (Rated)
Heating kW 3.48 4.29
COP Cooling (Rated) 4.20 3.90
COP (Rated) Heating (Rated) 4.60 4.20
Power Factor Rated - 0.93 0.93
Casing Color Warm Gray + RAL 7044 Warm Gray + RAL 7044
Heat Exchanger Wide Louver Plus Wide Louver Plus
Type LG Inverter Scroll LG Inverter Scroll
Piston Displacement cm3/rev 31.6 31.6
Motor Output x Number W x No. 3,198 x 1 3,198 x 1
Compressor
Starting Method DC Inverter Starting DC Inverter Starting
Oil Type FW68D FW68D
Oil Charge cc 1,100 1,100
Type Axial Flow Fan Axial Flow Fan
Motor Output x Number W 198 x 1 198 x 1
m3/min 80 80
Fan Air Flow Rate (High)
ft3/min 2,825 2,825
Drive DC INVERTER DC INVERTER
Discharge Side / Top Side Side
Liquid mm (inch) 9.52 (3/8) 9.52 (3/8)
Pipe Connections
Gas mm (inch) 15.88 (5/8) 19.05 (3/4)
mm 950 x 834 x 330 950 x 834 x 330
Dimensions (W x H x D)
inch 37-13/32 x 32-27/32 x 13 37-13/32 x 32-27/32 x 13
Net Weight kg 72 72
Cooling dB(A) 57 57
Sound Pressure Level
Heating dB(A) 60 63
Sound Power Level dB(A) - -
High pressure sensor / High pressure sensor /
High pressure protection -
High pressure switch High pressure switch
Over-heat protection / Over-heat protection /
Protection Devices Compressor/Fan -
Fan driver overload protector Fan driver overload protector
Over-heat protection / Over-heat protection /
Inverter -
Over-current protection Over-current protection
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A
kg 2.4 2.4
Refrigerant Precharged Amount
lbs 5.3 5.3
Control Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50
Number of maximum connectable indoor units 10 13

Note
1. Eurovent Test Condition : Type of indoor unit connected is only Ceiling Concealed Duct.
- Refer to EUROVENT certification regulation for more detail test conditions.
- Refer to EUROVENT website for test values connected Ceiling Cassette type indoors.
2. Performances are based on the following conditions :
- *1 Cooling : Indoot Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
- *2 Cooling : Indoor Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
- *Heating : Indoot Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
3. The maximum combination ratio is 160%. (the maximum combination ratio of ARUN050GSL0 is 130%.)
4. Wiring cable size must comply with the applicable local and national codes.
5. Due to our policy of innovation some specifications may be changed without notification.
6. Sound pressure level is measured on the rated condition in the anechoic rooms byISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms byISO 3741 standard.Therefore, these
values can be increased owing to ambient conditions during operation.
7. Power factor could vary less than ±1% according to the operating conditions.
8. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
076 / 077
OUTDOOR UNITS _ MULTI V S _ SPECIFICATION

MULTI V S HEAT PUMP


ARUN050LSS5 / ARUN060LSS5

HP 5 6
Model Name Combination Unit ARUN050LSS5 ARUN060LSS5
kW 14.0 15.5
Cooling Btu/h*1 47,800 52,900
Capacity (Rated) Btu/h*2 49,500 54,800
kW 16.0 18.0
Heating
Btu/h 54,600 61,400
Cooling kW 3.33 3.97
Input (Rated)
Heating kW 3.48 4.29
COP Cooling (Rated) 4.20 3.90
COP Heating (Rated) 4.60 4.20
Power Factor Rated - 0.93 0.93
Casing Color Warm Gray + RAL 7044 Warm Gray + RAL 7044
Heat Exchanger Wide Louver Plus Wide Louver Plus
Type LG Inverter Scroll LG Inverter Scroll
Piston Displacement cm3/rev 31.6 31.6
Motor Output x Number W x No. 3,198 x 1 3,198 x 1
Compressor
Starting Method DC Inverter Starting DC Inverter Starting
Oil Type FW68D FW68D
Oil Charge cc 1,100 1,100
Type Axial Flow Fan Axial Flow Fan
Motor Output x Number W 198 x 1 198 x 1
m3/min 80 80
Fan Air Flow Rate (High)
ft3/min 2,825 2,825
Drive DC INVERTER DC INVERTER
Discharge Side / Top Side Side
Liquid mm (inch) 9.52 (3/8) 9.52 (3/8)
Pipe Connections
Gas mm (inch) 15.88 (5/8) 19.05 (3/4)
mm 950 x 834 x 330 950 x 834 x 330
Dimensions (W x H x D)
inch 37-13/32 x 32-27/32 x 13 37-13/32 x 32-27/32 x 13
Net Weight kg 72 72
Cooling dB(A) 57 57
Sound Pressure Level
Heating dB(A) 60 63
Sound Power Level dB(A) - -
High pressure sensor / High pressure sensor /
High pressure protection -
High pressure switch High pressure switch
Over-heat protection / Over-heat protection /
Protection Devices Compressor/Fan -
Fan driver overload protector Fan driver overload protector
Over-heat protection / Over-heat protection /
Inverter -
Over-current protection Over-current protection
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant name R410A R410A
kg 2.4 2.4
Refrigerant Precharged Amount
lbs 5.3 5.3
Control Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50
Number of maximum connectable indoor units 10 13

Note
1. Eurovent Test Condition : Type of indoor unit connected is only Ceiling Concealed Duct.
- Refer to EUROVENT certification regulation for more detail test conditions.
- Refer to EUROVENT website for test values connected Ceiling Cassette type indoors.
2. Performances are based on the following conditions :
- * 1 Cooling : Indoot Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
- * 2 Cooling : Indoot Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
- *Heating : Indoot Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
3. The maximum combination ratio is 160%. (the maximum combination ratio of ARUN050GSL0 is 130%.)
4. Wiring cable size must comply with the applicable local and national codes.
5. Due to our policy of innovation some specifications may be changed without notification.
6. Sound pressure level is measured on the rated condition in the anechoic rooms byISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms byISO 3741 standard.Therefore, these
values can be increased owing to ambient conditions during operation.
7. Power factor could vary less than ±1% according to the operating conditions.
8. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
MULTI V S HEAT PUMP
ARUN080LSS0 / ARUN100LSS0 / ARUN120LSS0

HP 8 10 12
Model Name Combination Unit ARUN080LSS0 ARUN100LSS0 ARUN120LSS0
kW 22.4 28.0 33.6
Cooling (Rated) Btu/h*1 76,400 95,900 114,700
Capacity
Btu/h*2 78,300 98,100 117,300
Heating (Rated) kW 25.2 31.5 37.8
Cooling (Rated) kW 5.89 7.09 9.08
Input
Heating (Rated) kW 6.00 7.41 9.95
COP Cooling (Rated) 3.80 3.95 3.70
COP Heating (Rated) 4.20 4.25 3.80
Color (General) Warm Gray Warm Gray Warm Gray
Exterior
RAL Code (Classic), General RAL 7044 RAL 7044 RAL 7044
Heat Exchanger Type Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin Wide Louver Plus / Black Fin
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 1 (Inverter) x 1 (Inverter) x 1
Compressor Motor Output x Number W x No. 4,200 x 1 5,300 x 1 5,300 x 1
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 2,400 2,600 3,400
Type Propeller fan Propeller fan Propeller fan
Motor Output x Number W x No. 124 x 2 250 x 2 250 x 2
Fan Air Flow Rate (High) m3/min x No. 140 x 1 190 x 1 190 x 1
Drive DC INVERTER DC INVERTER DC INVERTER
Discharge Side / Top Side Side Side
Liquid Pipe mm (inch) Ø9.52 (3/8) Ø9.52 (3/8) Ø12.7 (1/2)
Pipe Connection
Gas Pipe mm (inch) Ø19.05 (3/4) Ø22.2 (7/8) Ø28.58 (1-1/8)
Dimensions (W x H x D) mm 950 x 1,380 x 330 1,090 x 1,625 x 380 1,090 x 1,625 x 380
Dimensions (W x H x D) - Shipping mm 1,140 x 1,462 x 461 1,215 x 1,795 x 500 1,215 x 1,795 x 500
Net Weight kg 115 144 157
Shipping Weight kg 127 160 173
Cooling dB(A) 57.0 58.0 60.0
Sound Pressure Level
Heating dB(A) 57.0 58.0 60.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in factory kg 3.5 4.5 6.0
Refrigerant
t-CO2eq 7.3 9.4 12.5
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 13 16 20

Note
1. Eurovent Test Condition : Type of indoor unit connected is only Ceiling Concealed Duct.
- Refer to EUROVENT certification regulation for more detail test conditions.
- Refer to EUROVENT website for test values connected Ceiling Cassette type indoors.
2. Performances are based on the following conditions :
- * 1 Cooling : Indoot Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
- * 2 Cooling : Indoot Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
- *Heating : Indoot Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
3. The maximum combination ratio is 160%. (the maximum combination ratio of ARUN050GSL0 is 130%.)
4. Wiring cable size must comply with the applicable local and national codes.
5. Due to our policy of innovation some specifications may be changed without notification.
6. Sound pressure level is measured on the rated condition in the anechoic rooms byISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms byISO 3741 standard.Therefore, these
values can be increased owing to ambient conditions during operation.
7. Power factor could vary less than ±1% according to the operating conditions.
8. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)

078 / 079
OUTDOOR UNITS _ MULTI V S _ SPECIFICATION

MULTI V S HEAT RECOVERY


ARUB060GSS4

HP 6
Model Name Combination Unit ARUB060GSS4
kW 15.5
Cooling (Rated)
Capacity Btu/h 52,900
Heating (Rated) kW 18.0
Cooling (Rated) kW 3.97
Input
Heating (Rated) kW 4.10
EER 3.90
COP Rated Capacity 4.39
Color Warm Gray
Exterior
RAL Code (Classic) RAL 7044
Heat Exchanger Type Wide Louver Plus
Type Hermetically Sealed Scroll
Combination x No. (Inverter) x 1
Compressor Motor Output x Number W x No. 4,200 x 1
Oil Type FVC68D (PVE)
Oil Charge cc 1,700
Type Axial Flow Fan
Motor Output x Number W x No. 124 x 2
Fan Air Flow Rate (High) m3/min x No. 110 x 1
Drive DC INVERTER
Discharge Side / Top Side
Liquid Pipe mm (inch) Ø9.52 (3/8)
Pipe Connection #1 Low Pressure Gas Pipe mm (inch) Ø19.05 (3/4)
High Pressure Gas Pipe mm (inch) Ø15.88 (5/8)
Dimensions (W x H x D) mm x No. (950 x 1,380 x 330) x 1
Dimensions (W x H x D) - shipping mm x No. (1,140 x 1,549 x 466) x 1
Net Weight kg x No. 118 x 1
Shipping Weight kg x No. 132 x 1
Cooling dB(A) 56.0
Sound Pressure Level
Heating dB(A) 58.0
Cooling dB(A) 76.0
Sound Power Level
Heating dB(A) 78.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A
Precharged Amount in factory kg 3.5
Refrigerant
t-CO2eq 7.3
Control Electronic Expansion Valve
Power Supply Ø, V, Hz 1, 220-240, 50
Number of Maximum Connectable Indoor Units 13

Note
1. Eurovent Test Condition : Type of indoor unit connected is only Ceiling Concealed Duct.
- Refer to EUROVENT certification regulation for more detail test conditions.
- Refer to EUROVENT website for test values connected Ceiling Cassette type indoors.
2. Performances are based on the following conditions :
- * 1 Cooling : Indoot Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB
- * 2 Cooling : Indoot Ambient Temp. 27°CDB / 19.5°CWB, Outdoor Ambient Temp. 35°CDB
- *Heating : Indoot Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
3. The maximum combination ratio is 160%. (the maximum combination ratio of ARUN050GSL0 is 130%.)
4. Wiring cable size must comply with the applicable local and national codes.
5. Due to our policy of innovation some specifications may be changed without notification.
6. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated
condition in the reverberation rooms by ISO 3741 standard. Therefore, these values can be increased owing to ambient conditions during operation.
7. Power factor could vary less than ±1% according to the operating conditions.
8. This product contains Fluorinated greenhouse gases. (R410A, GWP(Global warming potential) = 2087.5)
OUTDOOR UNITS _ MULTI V S _ APPLICATION GUIDE

MULTI V S
Energy Savings
Energy consumption can be reduced as indoor heat is absorbed and transferred to hot water supply.

Conventional
Absorbed heat is released to outdoor air.

Heat Heat Transfer


Released

Heat
Absorption

Conventional

Hot water

Boiler Domestic
(Gas or Electric) Hot Water Tank Hot Water Supply Cooling

MULTI V S Heat Recovery with HYDRO KIT


Absorbed heat from indoor space is used for making hot water.

Heat Transfer

HR Unit

Heat
Absorption

Heat Recovery

Hot water

HYDRO KIT Domestic


Hot Water Tank Hot Water Supply Cooling

080 / 081
- Water Cooled VRF Heat Pump & Heat Recovery
- 22.4 ~ 201.6kW (Cooling capacity based)
- 3Ø, 380 ~ 415V, 50Hz
- Outdoor unit installed indoor

TOTAL PIPING LENGTH

Economical, efficient
system
Longest piping length after 1st branch
40m (Conditional application)

40m
Height between
IDU ~ IDU

50m
Height between
ODU ~ IDU

Longest piping length from


150m ODU ~ IDU (Equivalent)

How does it work?


Operation independent of weather conditions

Energy savings
Outdoor Wind
Temp

Available in Heat Pump & Heat Recovery Configuration


Energy saving by heat
recovery unit

Heating based
Simultaneous operation
Space savings
External energy saving by between heat
recovery system

Cooling based
Simultaneous operation

Geothermal Application
37°C
Convenient installation Cooling
32°C
Tower

Water
Pump
Control
Room 1 Room 2 Room 3 Panel

Under Ground MULTI V


HEX WATER IV

082 / 083
OUTDOOR UNITS _ MULTI V S _ KEY FEATURES

INNOVATIVE ENERGY SAVING


TECHNOLOGIES Economical, Highly Efficient System
LG’s key technologies are integrated to inverter compressor
High Efficiency System Regardless of External With 4th generation inverter compressor, the MULTI V WATER IV boasts top-class
Conditions energy efficiency.
Regardless of outdoor temperature and other environmental conditions, MULTI V
Extended Compressor Speed 20Hz ~ 140Hz
WATER IV is the optimal solution. - Rapid operation response
- Capable of reaching required temperature quickly
- Increase part load efficiency

HiPORTM (High Pressure Oil Return)


- Eliminating loss in suction gas by returning oil directly to
compressor
- Resolve compressor efficiency loss caused by oil return

Active oil control (Oil level sensor)


- Oil recovery operation occurs only when required
Outdoor Temp Wind - Enhanced compressor reliability & continuous heating
- Oil distribution between compressors

Maximum COP
COP

Maximum COP 8.5


7
MULTI V WATER IV System for Geothermal
6
Applications
5
Uses underground heat sources like soil, ground water, lakes, rivers and more as Cooling based Heating based
4
renewable energy for cooling and heating. Water or antifreeze solution is circulated operation operation
through the closed loop HDPE (High Density Poly-Ethylene) pipes buried beneath the 0
earth’s surface. 20 40 60 80 100 Operation Ratio (%)
※ Outdoor unit water inlet temperature : 7°C
※ Indoor temperature : 20°C DB / 15°C WB
- The Circulating water temperature range is between -5°C ~ 45°C ※ Maximum COP Condition : Cooling 40% + Heating 60% operation
- Antifreeze should be applied depending on the application.
Economical, Highly Efficient System
Power Input (kWh)

2,000
1,800
Average
1,600
energy saving
1,400
1,200 12%
1,000
800
600
400
200
Previous Model MULTI V WATER IV

Pump
Machine Room
MULTI V WATER IV
LG’s 4th Generation Inverter Compressor
Efficiency (EER)

5.5 5% HEX Optimization


10%
Under ground 2% Cycle Composition Improvement
HEX 1% Inverter Control
5.0
1% Active Oil Control
1% HiPOR™

Chiller - FCU MULTI V WATER IV


Cooling Tower
Cooling Tower (Open type cooling towers can be used.) Previous Model MULTI V WATER IV
Ref. ※ Comparison between 10HP (28kW) in cooling mode
pipe.
(Independent
control)
Integrated Part Load Efficiency
Efficiency (EER)

FCU 6% HEX Optimization


13% 6.7
4% Cycle Composition Improvement
1% Inverter Control
5.8 1% Active Oil Control
1% HiPOR™
AHU
MULTI V
WATER IV

Water Water piping


Cooled Chiller Pump Pump Boiler Boiler MULTI V WATER II MULTI V WATER IV
(Space Saving)
Water piping Pump

Central control Independent control


WATER SAVINGS FLEXIBLE DESIGN & SPACE
Variable Water Flow Control (Option)
SAVINGS
In support of green building initiatives
The world’s first variable water flow control system for water cooled VRF system.
Largest Capacity
Sufficient pipe length limitation provides flexible design and
LG applied Variable Water Flow Control to optimize water flow control regarding
partial cooling or heating load conditions. Because of this it’s also possible to reduce installation
circulation pump energy consumption. Providing 8 ~ 20HP (22.4 ~ 56kW) with single unit, and up to the world’s largest
capacity 80HP (224kW) by combination.
HP 8 10 14 20 22 24 28 30 34 40 42 ~ 60 62 ~ 80
kW 22.4 28 39.2 56 61.6 67.2 78.4 84 95.2 112 117.6 ~ 168 173.6 ~ 224
Variable Water
Flow Control Valve
LG
CoolingTower DC 0 ~ 10V
1 Unit 2 Units 3 Units 4 Units

Inverter
Pump
Longest Piping Length
Geothermal
Sufficient pipes length limitation in design andInstallation of immense
PWFCKN00 variety of building
River / Sea
Provide flexible installation up to 300m of total piping length.
As water pipes are not connected to indoor units, users are free from water
leakage problems.
Total Water Flow (m3)

15,456 Longest piping length after 1st Height difference


71% branch 50m

Heightbetween
IDU

4,439
Total Piping Length 300m
Constant Water Flow Variable Water Flow Actual longest piping length (Equivalent) 150m (175m)
Note Longest piping length after 1st branch (Conditional application) 40m (90m)
1. Location : Paris, France
Height difference between ODU ~ IDU 50m
2. Office, 68,000m2
3. Operation time : 1,344 hours (Cooling period) Height difference between IDU ~ IDU 40m

Compact Size
Project Example : 63F (Pump : 20,064 LPM, 42.4mAq x 4ea) Thanks to compact size of product, it provides more space for
1) Inverter pump with MULTI V WATER and variable water flow control kit commercial or public use as much as possible.
2) Constant pump (Step control) with Water cooled VRF
The optimal design of the compact, lightweight outdoor unit enables double
10 years energy cost ($) stacking, which results in 50% savings in installation space.
Total Water Flow (m3)

Conventional MULTI V WATER IV


2,600,518 36%
[100%] 61%
Reduced

1,653,093 28kW x 4EA 56kW x 2EA


Per each Per each
880 x 550 mm 755 x 500 mm

※ 112kW, Floor area based

Constant Pump Inverter Pump


Lightweight
5 years 10 years
Nothing or Decrease additional load reinforcement work at building
Unit Pump Running Pump Running
Energy Use (kWh) Energy Use (kWh) Easier to transport and install thanks to 18% reduction in overall weight.
Cost ($) Cost ($)
Constant pump 7,952,040 1,142,441 15,904,080 2,600,518 18% 127kg
Reduced
MULTI V WATER IV
Inverter pump 5,054,940 726,225 10,109,880 1,653,093 154kg
Previous Model
• Power consumption rate : 0.13$/kWh
• Annual power consumption rate expected to increase by 5% ※ Based on 28kW

084 / 085
OUTDOOR UNITS _ MULTI V WATER IV _ TECHNICAL DATA

Nomenclature Operation Limits


ARW N 100 L A S 4 Cooling Heating
Serial number
45 45
S : Standard 40 40

Range for continuous operation


Inlet water Temperature (°C)

Inlet water Temperature (°C)

Range for continuous


Range for warming up operation
35 35

Range for pull down operation


A : Basic Function

operation
30
30
Electrical Ratings
25
L : 3Ø, 380 ~ 415 V, 50Hz
25
20
Total Cooling Capacity in Horse
20
Power (HP) unit
15
EX) 10HP → '100'
15 Range for
10 operation
Range for
Combination of Inverter Type and Cooling Only or Heat operation
Pump 10 -5
10 15 20 25 30 10 15 20 25 30
N: Inverter and H/P
Indoor Temperature (°C WB) Indoor Temperature (°C DB)
MULTI V Water System with Outdoor unit using R410A

Note
1. These figures assume the following operating conditions:
2. Equivalent piping length :7.5m
3. Level difference : 0m
Outdoor Units Function
Category Functions MULTI V WATER IV
Variable Path of Outdoor unit HEX -
HiPORTM (High Pressure Oil Return) ○ Position of Sound Pressure Level Measuring
Key Refrigerant
Humidity Sensor -
Components
Corrosion Resistance Black Fin -
Oil Sensor ○
Dual Sensing -
Low Noise Operation -
Hgih Static Mode of Outdoor Unit Fan -
Partial Defrosting -
Auto Dust Cleaning of Outdoor Unit (Fan
-
Useful Function reverse rotation)
Indoor Cooling Comfort Mode Based
-
Outdoor Temperature
Smart Load Control (SLC)
(Changingindoordischargeairtemperature -
according to load)
Outdoor Unit Control Refer to Humidity - Note
1. Data is valid at free field condition
Defrost / Deicing -
2. Data is valid at nominal operating condition
High Pressure Switch ○ 3. Sound level will vary depending on a range of factors such as the construction (Acoustic absorption
coefficient) of particular room in which the equipment is installed
Phase Protection ○
4. Sound level can be increased in static pressure mode or air guide application.
Reliability Restart Delay (3-minutes) ○
Self Diagnosis ○
Soft Start ○
Test Run Function ○
Optional Accessories
AC Ez (Simple Controller) PQCSZ250S0
AC Ez Touch PACEZA000 No. Name Model

AC Smart IV PACS4B000 ARBLN01621


Central Controller AC Smart 5 PACS5A000 ARBLN03321
ACP (Advanced Control Platform) IV PQCPC22A0
1 Y branch pipe ARBLN07121
ACP (Advanced Control Platform) 5 PACP5A000
AC Manager 5 PACM5A000 ARBLN14521

BNU (Building Network ACP Lonworks PLNWKB000 ARBLN23220


Unit) ACP BACnet PQNFB17C0 ARBL054
Refrigerant Charging Kit -
Installation ARBL057
Variable Water Flow Valve Control Kit PWFCKN000
ARBL104
PDI (Power Distribution Standard PPWRDB000 2 Header
Indicator) Premium PQNUD1S40 ARBL107
Cool / Heat Selector PRDSBM ARBL1010
Low Ambient Kit -
ARBL2010
IO Module (ODU Dry Contact) PVDSMN000
ARCNN21
LGMV PRCTIL0
Cycle Monitoring Device
Mobile LGMV PLGMVW100 3 Connection pipe of Outdoor Units ARCNN31
ARCNN41

※ ○ : Applied, - : Not Applied


MULTI V WATER IV Heating Dissipation Value by Model Precaution of Installation
Model HP Heating Dissipation Value 1. Do not install the unit at the outdoors. (Installation of the unit outdoors could
ARWN080LAS4 8 600 W 515.9 kcal/h 0.143 kcal/s result in fire or electric shock.) Recommended ambient temperature of outdoor
unit is between 0 ~ 40°C.
ARWN100LAS4 10 630 W 541.7 kcal/h 0.150 kcal/s
ARWN120LAS4 12 660 W 567.5 kcal/h 0.158 kcal/s 2. Keep the water temperature between 10 ~ 45°C. Standard water supply
ARWN140LAS4 14 690 W 593.3 kcal/h 0.165 kcal/s temperature is 30°C for cooling and 20°C for heating.
ARWN160LAS4 16 700 W 601.9 kcal/h 0.167 kcal/s
3. Establish an anti-freeze plan for the water supply when the product is stopped
ARWN180LAS4 18 720 W 619.1 kcal/h 0.172 kcal/s during the winter.
ARWN200LAS4 20 750 W 644.9 kcal/h 0.179 kcal/s
4. Be careful of the water purity control. Ensure water purity control to avoid
Test condition : Indoor air temperature : DB 40°C, WB : 32°C
※ A design stage should be considered to ventilation system in mechanical room. breakdown due to water pipe corrosion. Refer to ‘Standard Table for Water
Purity Control’ in PDB (Product Data Book).

5. The water pressure resistance of the water pipe system of this product is
ARWN080LAS4 / ARWN100LAS4 / ARWN140LAS4 / 1.98MPa.
ARWN200LAS4
[Unit : mm] 6. Always install a trap so that the drained water does not back flush.
755
7. Install a pressure gauge and temperature gauge at the inlet and outlet of the
water pipe.
500

8. Flexible joints must be installed not to cause any leakage from the vibration of
pipes.

9. Install a service port to clean the heat exchanger at the each end of the water
inlet and outlet.
Liquid pipe 79
10. It is recommended to install the flow switch to the water collection pipe system
Gas pipe 79
High/Low pressure connecting to the outdoor unit. (Flow switch acts as the 1st protection device
Common 79
Water pipe outlet
when the heat water is not supplied.)
58
997

11. When setting the flow switch, it is recommended to use the product with default
913
828

set value to satisfy the minimum flow rate of this product. (The minimum flow rate
742
635

58 range of this product is 50%.)


420

Water pipe
inlet
12. To protect the water cooling type product, you must install a strainer with 50
169

95

345
mesh or more on the heat water supply pipe. If not installed, it can result in
250
378
500 damage of heat exchanger by the following situation.
755
1) Heat water supply within the plate type heat exchanger is composed of
multiple small paths.
2) If you do not use a strainer with 50 mesh or more, alien particles can
Individual Installation
partially block the water paths.
3) When running the heater, the plate type heat exchanger plays the role of
the evaporator, and at this time, the temperature of the refrigerant side
drops to drop the temperature of the heat water supply, which can result in
icing point in the water paths.
4) As the heating process progresses, the water paths can be partially frozen
to lead to damage in plate type heat exchanger.
5) As a result of the damage of the heat exchanger from the freezing, the
refrigerant side and the heat water source side will be mixed to make the
product unusable.

Water Piping Installation

086 / 087
OUTDOOR UNITS _ MULTI V WATER IV _ REFERENCE SITE

REFERENCE SITE
Bouygues Challenger
LG MULTI V WATER Solution with Geothermal Application

Site Information
The industrial group Bouygues was established in France in 1952. It now maintains operations in 80 countries and employs more than 131,000 people. In 1988, after two years of
construction, the new headquarters for Bouygues Construction was officially opened for business. Named Challenger, the complex became a technological showcase for late 20th
century architecture.

LG Solution
Bouygues decided to convert their headquarters into an eco-friendly building by significantly reducing its energy footprint. The LG MULTI V Water system was chosen as the ideal HVAC
solution for this project. The system not only saves energy but also reduces water usage as it recycles water in order to regulate the temperature of the building. With LG’s advanced
technology, the building’s water consumption was reduced by more than 70 percent.
OUTDOOR UNITS _ MULTI V WATER IV _ SPECIFICATION

MULTI V WATER IV HEAT PUMP


ARWN080LAS4 / ARWN100LAS4
ARWN140LAS4

HP 8 10 14
Combination Unit ARWN080LAS4 ARWN100LAS4 ARWN140LAS4
Model Name
Independent Unit ARWN080LAS4 ARWN100LAS4 ARWN140LAS4
kW 22.4 28.0 39.2
Cooling (Rated)
Capacity Btu/h 76,800 95,900 133,800
Heating (Rated) kW 25.2 31.5 44.1
Cooling (Rated) kW 3.86 5.09 7.84
Input
Heating (Rated) kW 4.2 5.34 8.17
EER 5.80 5.50 5.00
COP Rated Capacity 6.00 5.90 5.40
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 10.7 15.8 28.6
Rated Water Flow LPM 77 96 135
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 1 (Inverter) x 1 (Inverter) x 1
Compressor Motor Output x Number W x No. 4,200 x 1 4,200 x 1 4,200 x 1
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 2,800 2,800 2,800
Refrigerant Liquid Pipe mm (inch) Ø9.52 (3/8) Ø9.52 (3/8) Ø12.7 (1/2)
Connecting Pipes Gas Pipe mm (inch) Ø22.2 (7/8) Ø22.2 (7/8) Ø25.4 (1)
Inlet A (inch) 40A(PT 1-1/2) (Internal Thread) 40A(PT 1-1/2) (Internal Thread) 40A(PT 1-1/2) (Internal Thread)
Water Connecting Pipes Outlet A (inch) 40A(PT 1-1/2) (Internal Thread) 40A(PT 1-1/2) (Internal Thread) 40A(PT 1-1/2) (Internal Thread)
Drain Outlet A (inch) 20A(PT 3/4) (External Thread) 20A(PT 3/4) (External Thread) 20A(PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 1 (755 x 997 x 500) x 1 (755 x 997 x 500) x 1
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 1 (804 x 1,143 x 630) x 1 (804 x 1,143 x 630) x 1
Net Weight kg x No. 127 x 1 127 x 1 127 x 1
Shipping Weight kg x No. 137 x 1 137 x 1 137 x 1
Sound Cooling dB(A) 47.0 50.0 58.0
Pressure Level Heating dB(A) 51.0 53.0 57.0
Sound Cooling dB(A) 59.0 62.0 70.0
Power Level Heating dB(A) 63.0 65.0 69.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 5.8 5.8 5.8
Refrigerant Factory
t-CO2eq 12.1 12.1 12.1
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 13 (20) 16 (25) 23 (35)

Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected.The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160%
~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms byISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms byISO 3741 standard.Therefore, these
values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)

088 / 089
OUTDOOR UNITS _ MULTI V WATER IV _ SPECIFICATION

MULTI V WATER IV HEAT PUMP


ARWN200LAS4 / ARWN160LAS4
ARWN180LAS4

HP 20 16 18
Combination Unit ARWN200LAS4 ARWN160LAS4 ARWN180LAS4
Model Name ARWN080LAS4 ARWN100LAS4
Independent Unit ARWN200LAS4
ARWN080LAS4 ARWN080LAS4
kW 56.0 44.8 50.4
Cooling (Rated)
Capacity Btu/h 191,00 153,600 172,700
Heating (Rated) kW 63.0 50.4 56.7
Cooling (Rated) kW 11.20 7.72 8.95
Input
Heating (Rated) kW 11.67 8.40 9.54
EER 5.00 5.80 5.63
COP Rated Capacity 5.40 6.00 5.94
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 30.1 10.7 + 10.7 15.8 + 10.7
Rated Water Flow LPM 192 77 + 77 96 + 77
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 1 (Inverter) x 2 (Inverter) x 2
Compressor Motor Output x Number W x No. 5,300 x 1 4,200 x 2 4,200 x 2
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 3,000 5,600 5,600
Refrigerant Liquid Pipe mm (inch) Ø12.7 (1/2) Ø12.7 (1/2) Ø12.7 (1/2)
Connecting Pipes Gas Pipe mm (inch) Ø28.58 (1-1/8) Ø28.58 (1-1/8) Ø28.58 (1-1/8)
40A (PT 1-1/2) + 40A (PT 1-1/2) (Internal 40A (PT 1-1/2) + 40A (PT 1-1/2) (Internal
Inlet A (inch) 40A (PT 1-1/2) (Internal Thread)
Thread) Thread)
Water Connecting Pipes Outlet 40A (PT 1-1/2) + 40A (PT 1-1/2) (Internal 40A (PT 1-1/2) + 40A (PT 1-1/2) (Internal
A (inch) 40A (PT 1-1/2) (Internal Thread)
Thread) Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 1 (755 x 997 x 500) x 2 (755 x 997 x 500) x 2
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 1 (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2
Net Weight kg x No. 140 x 1 127 x 2 127 x 2
Shipping Weight kg x No. 150 x 1 137 x 2 137 x 2
Sound Cooling dB(A) 54.0 50.0 51.8
Pressure Level Heating dB(A) 60.0 54.0 55.1
Sound Cooling dB(A) 66.0 62.0 63.8
Power Level Heating dB(A) 72.0 66.0 67.1
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 3.0 11.6 11.6
Refrigerant Factory
t-CO2eq 6.3 24.2 24.2
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 32 (50) 26 (40) 29 (45)

Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected.The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160%
~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms byISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms byISO 3741 standard.Therefore, these
values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
MULTI V WATER IV HEAT PUMP
ARWN220LAS4 / ARWN240LAS4
ARWN280LAS4

HP 22 24 28
Combination Unit ARWN220LAS4 ARWN240LAS4 ARWN280LAS4
Model Name ARWN140LAS4 ARWN140LAS4 ARWN140LAS4
Independent Unit
ARWN080LAS4 ARWN100LAS4 ARWN140LAS4
kW 61.6 67.2 78.4
Cooling (Rated)
Capacity Btu/h 210,600 229,700 267,600
Heating (Rated) kW 69.3 75.6 88.2
Cooling (Rated) kW 11.70 12.93 15.68
Input
Heating (Rated) kW 12.37 13.51 16.34
EER 5.26 5.20 5.00
COP Rated Capacity 5.60 5.60 5.40
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 28.6 + 10.7 28.6 + 15.8 28.6 + 28.6
Rated Water Flow LPM 135 + 77 135 + 96 135 + 135
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 2 (Inverter) x 2 (Inverter) x 2
Compressor Motor Output x Number W x No. 4,200 x 2 4,200 x 2 4,200 x 2
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 5,600 5,600 5,600
Refrigerant Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Connecting Pipes Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8)
40A (PT 1-1/2) + 40A (PT 1-1/2) (Internal 40A (PT 1-1/2) + 40A (PT 1-1/2) (Internal 40A (PT 1-1/2) + 40A (PT 1-1/2) (Internal
Inlet A (inch)
Thread) Thread) Thread)
Water Connecting Pipes Outlet 40A (PT 1-1/2) + 40A (PT 1-1/2) (Internal 40A (PT 1-1/2) + 40A (PT 1-1/2) (Internal 40A (PT 1-1/2) + 40A (PT 1-1/2) (Internal
A (inch)
Thread) Thread) Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 2 (755 x 997 x 500) x 2 (755 x 997 x 500) x 2
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2
Net Weight kg x No. 127 x 2 127 x 2 127 x 2
Shipping Weight kg x No. 137 x 2 137 x 2 137 x 2
Sound Cooling dB(A) 58.3 58.6 59.0
Pressure Level Heating dB(A) 58.0 58.5 58.0
Sound Cooling dB(A) 70.3 70.6 72.0
Power Level Heating dB(A) 70.0 70.5 71.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 11.6 11.6 11.6
Refrigerant Factory
t-CO2eq 24.2 24.2 24.2
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 35 (44) 39 (48) 45 (56)

Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected.The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160%
~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms byISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms byISO 3741 standard.Therefore, these
values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)

090 / 091
OUTDOOR UNITS _ MULTI V WATER IV _ SPECIFICATION

MULTI V WATER IV HEAT PUMP


ARWN300LAS4 / ARWN340LAS4
ARWN400LAS4

HP 30 34 40
Combination Unit ARWN300LAS4 ARWN340LAS4 ARWN400LAS4
Model Name ARWN200LAS4 ARWN200LAS4 ARWN200LAS4
Independent Unit
ARWN100LAS4 ARWN140LAS4 ARWN200LAS4
kW 84.0 95.2 112.0
Cooling (Rated)
Capacity Btu/h 286,700 324,900 382,200
Heating (Rated) kW 94.5 107.1 126.0
Cooling (Rated) kW 16.29 19.04 22.40
Input
Heating (Rated) kW 17.01 19.84 23.34
EER 5.16 5.00 5.00
COP Rated Capacity 5.56 5.40 5.40
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 30.1 + 15.8 30.1 + 28.6 30.1 + 30.1
Rated Water Flow LPM 192 + 96 192 + 135 192 + 192
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 2 (Inverter) x 2 (Inverter) x 2
Compressor Motor Output x Number W x No. 5,300 x 1 + 4,200 x 1 5,300 x 1 + 4,200 x 1 5,300 x 2
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 5,800 5,800 6,000
Refrigerant Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Connecting Pipes Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø41.3 (1-5/8)
40A (PT 1-1/2) + 40A (PT 1-1/2) (Internal 40A (PT 1-1/2) + 40A (PT 1-1/2) (Internal 40A (PT 1-1/2) + 40A (PT 1-1/2) (Internal
Inlet A (inch)
Thread) Thread) Thread)
Water Connecting Pipes Outlet 40A (PT 1-1/2) + 40A (PT 1-1/2) (Internal 40A (PT 1-1/2) + 40A (PT 1-1/2) (Internal 40A (PT 1-1/2) + 40A (PT 1-1/2) (Internal
A (inch)
Thread) Thread) Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 2 (755 x 997 x 500) x 2 (755 x 997 x 500) x 2
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2
Net Weight kg x No. (140 x 1) + (127 x 1) (140 x 1) + (127 x 1) 140 x 2
Shipping Weight kg x No. (150 x 1) + (137 x 1) (150 x 1) + (137 x 1) 150 x 2
Sound Cooling dB(A) 55.5 59.0 55.0
Pressure Level Heating dB(A) 60.8 61.0 61.0
Sound Cooling dB(A) 67.5 72.0 68.0
Power Level Heating dB(A) 72.8 74.0 74.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 8.8 8.8 6.0
Refrigerant Factory
t-CO2eq 18.4 18.4 12.5
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 49 (60) 55 (64) 64

Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected.The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160%
~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms byISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms byISO 3741 standard.Therefore, these
values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
MULTI V WATER IV HEAT PUMP
ARWN420LAS4 / ARWN440LAS4
ARWN480LAS4

HP 42 44 48
Combination Unit ARWN420LAS4 ARWN440LAS4 ARWN480LAS4
Model Name ARWN200LAS4 ARWN200LAS4 ARWN200LAS4
Independent Unit ARWN140LAS4 ARWN140LAS4 ARWN140LAS4
ARWN080LAS4 ARWN100LAS4 ARWN140LAS4
kW 117.6 123.2 134.4
Cooling (Rated)
Capacity Btu/h 401,700 420,800 459,000
Heating (Rated) kW 132.3 138.6 151.2
Cooling (Rated) kW 22.9 24.13 26.88
Input
Heating (Rated) kW 24.04 25.18 28.01
EER 5.14 5.11 5.00
COP Rated Capacity 5.50 5.50 5.40
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 30.1 + 28.6 + 10.7 30.1 + 28.6 + 15.8 30.1 + 28.6 + 28.6
Rated Water Flow LPM 192 + 135 + 77 192 + 135 + 96 192 + 135 + 135
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 3 (Inverter) x 3 (Inverter) x 3
Compressor Motor Output x Number W x No. 5,300 x 1 + 4,200 x 2 5,300 x 1 + 4,200 x 2 5,300 x 1 + 4,200 x 2
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 8,600 8,600 8,600
Refrigerant Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Connecting Pipes Gas Pipe mm (inch) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8)
40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT
Inlet A (inch)
1-1/2) (Internal Thread) 1-1/2) (Internal Thread) 1-1/2) (Internal Thread)
Water Connecting Pipes Outlet 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT
A (inch)
1-1/2) (Internal Thread) 1-1/2) (Internal Thread) 1-1/2) (Internal Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 3 (755 x 997 x 500) x 3 (755 x 997 x 500) x 3
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3
Net Weight kg x No. (140 x 1) + (127 x 2) (140 x 1) + (127 x 2) (140 x 1) + (127 x 2)
Shipping Weight kg x No. (150 x 1) + (137 x 2) (150 x 1) + (137 x 2) (150 x 1) + (137 x 2)
Sound Cooling dB(A) 59.7 59.9 60.0
Pressure Level Heating dB(A) 62.1 62.3 62.0
Sound Cooling dB(A) 71.7 71.9 74.0
Power Level Heating dB(A) 74.1 74.3 76.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 14.6 14.6 14.6
Refrigerant Factory
t-CO2eq 30.5 30.5 30.5
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 64 64 64

Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected.The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160%
~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms byISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms byISO 3741 standard.Therefore, these
values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)

092 / 093
OUTDOOR UNITS _ MULTI V WATER IV _ SPECIFICATION

MULTI V WATER IV HEAT PUMP


ARWN500LAS4 / ARWN540LAS4
ARWN600LAS4

HP 50 54 60
Combination Unit ARWN500LAS4 ARWN540LAS4 ARWN600LAS4
Model Name ARWN200LAS4 ARWN200LAS4 ARWN200LAS4
Independent Unit ARWN200LAS4 ARWN200LAS4 ARWN200LAS4
ARWN100LAS4 ARWN140LAS4 ARWN200LAS4
kW 140.0 151.2 168.0
Cooling (Rated)
Capacity Btu/h 478,100 516,000 573,300
Heating (Rated) kW 157.5 170.1 189.0
Cooling (Rated) kW 27.49 30.24 33.60
Input
Heating (Rated) kW 28.68 31.51 35.01
EER 5.09 5.00 5.00
COP Rated Capacity 5.49 5.40 5.40
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 30.1 + 30.1 + 15.8 30.1 + 28.6 + 28.6 30.1 + 30.1 + 30.1
Rated Water Flow LPM 192 + 192 + 96 192 + 192 + 135 192 + 192+ 192
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 3 (Inverter) x 3 (Inverter) x 3
Compressor Motor Output x Number W x No. 5,300 x 2 + 4,200 x 1 5,300 x 2 + 4,200 x 1 5,300 x 3
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 8,800 8,800 9,000
Refrigerant Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Connecting Pipes Gas Pipe mm (inch) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8)
40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT
Inlet A (inch)
1-1/2) (Internal Thread) 1-1/2) (Internal Thread) 1-1/2) (Internal Thread)
Water Connecting Pipes Outlet 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT
A (inch)
1-1/2) (Internal Thread) 1-1/2) (Internal Thread) 1-1/2) (Internal Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 3 (755 x 997 x 500) x 3 (755 x 997 x 500) x 3
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3
Net Weight kg x No. (140 x 2) + (127 x 1) (140 x 2) + (127 x 1) 140 x 3
Shipping Weight kg x No. (150 x 2) + (137 x 1) (150 x 2) + (137 x 1) 150 x 3
Sound Cooling dB(A) 57.8 60.0 56.0
Pressure Level Heating dB(A) 63.4 62.0 62.0
Sound Cooling dB(A) 69.8 74.0 70.0
Power Level Heating dB(A) 75.4 76.0 76.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 11.8 11.8 9.0
Refrigerant Factory
t-CO2eq 24.6 24.6 18.8
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 64 64 64

Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected.The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160%
~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms byISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms byISO 3741 standard.Therefore, these
values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
MULTI V WATER IV HEAT PUMP
ARWN620LAS4 / ARWN640LAS4
ARWN680LAS4

HP 62 64 68
Combination Unit ARWN620LAS4 ARWN640LAS4 ARWN680LAS4
ARWN200LAS4 ARWN200LAS4 ARWN200LAS4
Model Name ARWN200LAS4 ARWN200LAS4 ARWN200LAS4
Independent Unit
ARWN140LAS4 ARWN140LAS4 ARWN140LAS4
ARWN080LAS4 ARWN100LAS4 ARWN140LAS4
kW 173.6 179.2 190.4
Cooling (Rated)
Capacity Btu/h 592,700 611,600 649,800
Heating (Rated) kW 195.3 201.6 214.2
Cooling (Rated) kW 34.10 35.33 38.08
Input
Heating (Rated) kW 35.71 36.85 39.68
EER 5.09 5.07 5.00
COP Rated Capacity 5.47 5.47 5.40
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 30.1 + 30.1 + 28.6 + 10.7 30.1 + 30.1 + 28.6 + 15.8 30.1 + 30.1 + 28.6 + 28.6
Rated Water Flow LPM 192 + 192 + 135 + 77 192 + 192 + 135 + 96 192 + 192 + 135 + 135
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 4 (Inverter) x 4 (Inverter) x 4
Compressor Motor Output x Number W x No. 5,300 x 2 + 4,200 x 2 5,300 x 2 + 4,200 x 2 5,300 x 2 + 4,200 x 2
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 11,600 11,600 11,600
Refrigerant Liquid Pipe mm (inch) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8)
Connecting Pipes Gas Pipe mm (inch) Ø44.5 (1-3/4) Ø44.5 (1-3/4) Ø53.98 (2-1/8)
40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Inlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40
(Internal Thread) (Internal Thread) (Internal Thread)
Water Connecting Pipes 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Outlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40
(Internal Thread) (Internal Thread) (Internal Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 4 (755 x 997 x 500) x 4 (755 x 997 x 500) x 4
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4
Net Weight kg x No. (140 x 2) + (127 x 2) (140 x 2) + (127 x 2) (140 x 2) + (127 x 2)
Shipping Weight kg x No. (150 x 2) + (137 x 2) (150 x 2) + (137 x 2) (150 x 2) + (137 x 2)
Sound Cooling dB(A) 60.7 60.9 61.0
Pressure Level Heating dB(A) 64.2 64.3 63.0
Sound Cooling dB(A) 72.7 72.9 75.0
Power Level Heating dB(A) 76.2 76.3 77.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 17.6 17.6 17.6
Refrigerant Factory
t-CO2eq 36.7 36.7 36.7
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 64 64 64

Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected.The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160%
~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms byISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms byISO 3741 standard.Therefore, these
values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)

094 / 095
OUTDOOR UNITS _ MULTI V WATER IV _ SPECIFICATION

MULTI V WATER IV HEAT PUMP


ARWN700LAS4 / ARWN740LAS4
ARWN800LAS4

HP 70 74 80
Combination Unit ARWN700LAS4 ARWN740LAS4 ARWN800LAS4
ARWN200LAS4 ARWN200LAS4 ARWN200LAS4
Model Name ARWN200LAS4 ARWN200LAS4 ARWN200LAS4
Independent Unit
ARWN200LAS4 ARWN200LAS4 ARWN200LAS4
ARWN100LAS4 ARWN140LAS4 ARWN200LAS4
kW 196.0 207.2 224.0
Cooling (Rated)
Capacity Btu/h 668,900 707,100 764,400
Heating (Rated) kW 220.5 233.1 252.0
Cooling (Rated) kW 38.69 41.44 44.80
Input
Heating (Rated) kW 40.35 43.18 46.68
EER 5.07 5.00 5.00
COP Rated Capacity 5.46 5.40 5.40
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure 2
kgf/cm 45 45 45
Heat Exchanger Resistance
Head Loss kPa 30.1 + 30.1 + 30.1 + 15.8 30.1 + 30.1 + 30.1 + 28.6 30.1 + 30.1 + 30.1 + 30.1
Rated Water Flow LPM 192 + 192 + 192 + 96 192 + 192 + 192 + 135 192 + 192 + 192 + 192
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 4 (Inverter) x 4 (Inverter) x 4
Compressor Motor Output x Number W x No. 5,300 x 3 + 4,200 x 1 5,300 x 3 + 4,200 x 1 5,300 x 4
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 11,800 11,800 12,000
Refrigerant Liquid Pipe mm (inch) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8)
Connecting Pipes Gas Pipe mm (inch) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8)
40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Inlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40
(Internal Thread) (Internal Thread) (Internal Thread)
Water Connecting Pipes 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Outlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40
(Internal Thread) (Internal Thread) (Internal Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 4 (755 x 997 x 500) x 4 (755 x 997 x 500) x 4
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4
Net Weight kg x No. (140 x 3) + (127 x 1) (140 x 3) + (127 x 1) 140 x 4
Shipping Weight kg x No. (150 x 3) + (137 x 1) (150 x 3) + (137 x 1) 150 x 4
Sound Cooling dB(A) 59.3 61.0 57.0
Pressure Level Heating dB(A) 65.1 63.0 63.0
Sound Cooling dB(A) 71.3 75.0 71.0
Power Level Heating dB(A) 77.1 77.0 77.0
No.x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 14.8 14.8 12.0
Refrigerant Factory
t-CO2eq 30.9 30.9 25.1
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 64 64 64

Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected.The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160%
~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms byISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms byISO 3741 standard.Therefore, these
values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
MULTI V WATER IV HEAT RECOVERY
ARWB080LAS4 / ARWB100LAS4
ARWB140LAS4

HP 8 10 14
Combination Unit ARWB080LAS4 ARWB100LAS4 ARWB140LAS4
Model Name
Independent Unit ARWB080LAS4 ARWB100LAS4 ARWB140LAS4
kW 22.4 28.0 39.2
Cooling (Rated)
Capacity Btu/h 76,800 95,900 133,800
Heating (Rated) kW 25.2 31.5 44.1
Cooling (Rated) kW 3.86 5.09 7.84
Input
Heating (Rated) kW 4.20 5.34 8.17
EER 5.80 5.50 5.00
COP Rated Capacity 6.00 5.90 5.40
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 10.7 15.8 28.6
Rated Water Flow LPM 77 96 135
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 1 (Inverter) x 1 (Inverter) x 1
Compressor Motor Output x Number W x No. 4,200 x 1 4,200 x 1 4,200 x 1
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 2,800 2,800 2,800
Liquid Pipe mm (inch) Ø9.52 (3/8) Ø9.52 (3/8) Ø12.7 (1/2)
Refrigerant
Low Pressure Gas Pipe mm (inch) Ø22.2 (7/8) Ø22.2 (7/8) Ø25.4 (1)
Connecting Pipes
High Pressure Gas Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Inlet A (inch) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread)
Water Connecting Pipes Outlet A (inch) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread) 40A (PT 1-1/2) (Internal Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 1 (755 x 997 x 500) x 1 (755 x 997 x 500) x 1
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 1 (804 x 1,143 x 630) x 1 (804 x 1,143 x 630) x 1
Net Weight kg x No. 127 x 1 127 x 1 127 x 1
Shipping Weight kg x No. 137 x 1 137 x 1 137 x 1
Sound Cooling dB(A) 47.0 50.0 58.0
Pressure Level Heating dB(A) 51.0 53.0 57.0
Sound Cooling dB(A) 59.0 62.0 70.0
Power Level Heating dB(A) 63.0 65.0 69.0
No.x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 5.8 5.8 5.8
Refrigerant Factory
t-CO2eq 12.1 12.1 12.1
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 1) 13 (20) 16 (25) 23 (35)

Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected.The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160%
~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms byISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms byISO 3741 standard.Therefore, these
values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)

096 / 097
OUTDOOR UNITS _ MULTI V WATER IV _ SPECIFICATION

MULTI V WATER IV HEAT RECOVERY


ARWB200LAS4 / ARWB160LAS4
ARWB180LAS4

HP 20 16 18
Combination Unit ARWB200LAS4 ARWB160LAS4 ARWB180LAS4
Model Name ARWB080LAS4 ARWB100LAS4
Independent Unit ARWB200LAS4
ARWB080LAS4 ARWB080LAS4
kW 56.0 44.8 50.4
Cooling (Rated)
Capacity Btu/h 191,000 152,900 172,000
Heating (Rated) kW 63.0 50.4 56.7
Cooling (Rated) kW 11.20 7.72 8.95
Input
Heating (Rated) kW 11.67 8.40 9.54
EER 5.00 5.80 5.63
COP Rated Capacity 5.40 6.00 5.94
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 30.1 10.7 + 10.7 15.8 + 10.7
Rated Water Flow LPM 192 77 + 77 96 + 77
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 1 (Inverter) x 2 (Inverter) x 2
Compressor Motor Output x Number W x No. 5,300 x 1 4,200 x 2 4,200 x 2
Oil Type FVC68D(PVE) FVC68D(PVE) FVC68D(PVE)
Oil Charge cc 3,000 5,600 5,600
Liquid Pipe mm (inch) Ø12.7 (1/2) Ø12.7 (1/2) Ø12.7 (1/2)
Refrigerant
Low Pressure Gas Pipe mm (inch) Ø28.58 (1-1/8) Ø28.58 (1-1/8) Ø28.58 (1-1/8)
Connecting Pipes
High Pressure Gas Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
40A(PT 1-1/2) + 40A(PT 1-1/2) (Internal 40A(PT 1-1/2) + 40A(PT 1-1/2) (Internal
Inlet A (inch) 40A(PT 1-1/2) (Internal Thread)
Thread) Thread)
Water Connecting Pipes Outlet 40A(PT 1-1/2) + 40A(PT 1-1/2) (Internal 40A(PT 1-1/2) + 40A(PT 1-1/2) (Internal
A (inch) 40A(PT 1-1/2) (Internal Thread)
Thread) Thread)
Drain Outlet A (inch) 20A(PT 3/4) (External Thread) 20A(PT 3/4) (External Thread) 20A(PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 1 (755 x 997 x 500) x 2 (755 x 997 x 500) x 2
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 1 (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2
Net Weight kg x No. 140 x 1 127 x 2 127 x 2
Shipping Weight kg x No. 150 x 1 137 x 2 137 x 2
Sound Cooling dB(A) 54.0 50.0 52.0
Pressure Level Heating dB(A) 60.0 54.0 55.0
Sound Cooling dB(A) 66.0 62.0 64.0
Power Level Heating dB(A) 72.0 66.0 67.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 3.0 11.6 11.6
Refrigerant Factory
t-CO2eq 6.3 24.2 24.2
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 32(50) 26(40) 29(45)

Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected.The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160%
~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms byISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms byISO 3741 standard.Therefore, these
values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
MULTI V WATER IV HEAT RECOVERY
ARWB220LAS4 / ARWB240LAS4
ARWB280LAS4

HP 22 24 28
Combination Unit ARWB220LAS4 ARWB240LAS4 ARWB280LAS4
Model Name ARWB140LAS4 ARWB140LAS4 ARWB140LAS4
Independent Unit
ARWB080LAS4 ARWB100LAS4 ARWB140LAS4
kW 61.6 67.2 78.4
Cooling (Rated)
Capacity Btu/h 210,600 229,400 267,600
Heating (Rated) kW 69.3 75.6 88.2
Cooling (Rated) kW 11.70 12.93 15.68
Input
Heating (Rated) kW 12.37 13.51 16.34
EER 5.26 5.20 5.00
COP Rated Capacity 5.60 5.60 5.40
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 28.6 + 10.7 28.6 + 15.8 28.6 + 28.6
Rated Water Flow LPM 135 + 77 135 + 96 135 + 135
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 2 (Inverter) x 2 (Inverter) x 2
Compressor Motor Output x Number W x No. 4,200 x 2 4,200 x 2 4,200 x 2
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 5,600 5,600 5,600
Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Refrigerant
Low Pressure Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8)
Connecting Pipes
High Pressure Gas Pipe mm (inch) Ø28.58 (1-1/8) Ø28.58 (1-1/8) Ø28.58 (1-1/8)
40A (PT 1-1/2) + 40A (PT 1-1/2) (Internal 40A (PT 1-1/2) + 40A (PT 1-1/2) (Internal 40A (PT 1-1/2) + 40A (PT 1-1/2) (Internal
Inlet A (inch)
Thread) Thread) Thread)
Water Connecting Pipes Outlet 40A (PT 1-1/2) + 40A (PT 1-1/2) (Internal 40A (PT 1-1/2) + 40A (PT 1-1/2) (Internal 40A (PT 1-1/2) + 40A (PT 1-1/2) (Internal
A (inch)
Thread) Thread) Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 2 (755 x 997 x 500) x 2 (755 x 997 x 500) x 2
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2
Net Weight kg x No. 127 x 2 127 x 2 127 x 2
Shipping Weight kg x No. 137 x 2 137 x 2 137 x 2
Sound Cooling dB(A) 58.0 59.0 59.0
Pressure Level Heating dB(A) 58.0 58.0 58.0
Sound Cooling dB(A) 70.0 71.0 72.0
Power Level Heating dB(A) 70.0 70.0 71.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 11.6 11.6 11.6
Refrigerant Factory
t-CO2eq 24.2 24.2 24.2
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 35 (44) 39 (48) 45 (56)

Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected.The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160%
~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms byISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms byISO 3741 standard.Therefore, these
values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)

098 / 099
OUTDOOR UNITS _ MULTI V WATER IV _ SPECIFICATION

MULTI V WATER IV HEAT RECOVERY


ARWB300LAS4 / ARWB340LAS4
ARWB400LAS4

HP 30 34 40
Combination Unit ARWB300LAS4 ARWB340LAS4 ARWB400LAS4
Model Name ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
Independent Unit
ARWB100LAS4 ARWB140LAS4 ARWB200LAS4
kW 84.0 95.2 112.0
Cooling (Rated)
Capacity Btu/h 286,700 324,900 382,200
Heating (Rated) kW 94.5 107.1 126.0
Cooling (Rated) kW 16.29 19.04 22.40
Input
Heating (Rated) kW 17.01 19.84 23.34
EER 5.16 5.00 5.00
COP Rated Capacity 5.56 5.40 5.40
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 30.1 + 15.8 30.1 + 28.6 30.1 + 30.1
Rated Water Flow LPM 192 + 96 192 + 135 192 + 192
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 2 (Inverter) x 2 (Inverter) x 2
Compressor Motor Output x Number W x No. 5,300 x 1 + 4,200 x 1 5,300 x 1 + 4,200 x 1 5,300 x 2
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 5,800 5,800 6,000
Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Refrigerant
Low Pressure Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø41.3 (1-5/8)
Connecting Pipes
High Pressure Gas Pipe mm (inch) Ø28.58 (1-1/8) Ø28.58 (1-1/8) Ø34.9 (1-3/8)
40A (PT 1-1/2) + 40A (PT 1-1/2) (Internal 40A (PT 1-1/2) + 40A (PT 1-1/2) (Internal 40A (PT 1-1/2) + 40A (PT 1-1/2) (Internal
Inlet A (inch)
Thread) Thread) Thread)
Water Connecting Pipes Outlet 40A (PT 1-1/2) + 40A (PT 1-1/2) (Internal 40A (PT 1-1/2) + 40A (PT 1-1/2) (Internal 40A (PT 1-1/2) + 40A (PT 1-1/2) (Internal
A (inch)
Thread) Thread) Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 2 (755 x 997 x 500) x 2 (755 x 997 x 500) x 2
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2 (804 x 1,143 x 630) x 2
Net Weight kg x No. (140 x 1) + (127 x 1) (140 x 1) + (127 x 1) 140 x 2
Shipping Weight kg x No. (150 x 1) + (137 x 1) (150 x 1) + (137 x 1) 150 x 2
Sound Cooling dB(A) 55.0 59.0 55.0
Pressure Level Heating dB(A) 61.0 61.0 61.0
Sound Cooling dB(A) 67.0 72.0 68.0
Power Level Heating dB(A) 73.0 74.0 74.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 8.8 8.8 6.0
Refrigerant Factory
t-CO2eq 18.4 18.4 12.5
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 49 (60) 55 (64) 64

Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected.The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160%
~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms byISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms byISO 3741 standard.Therefore, these
values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
MULTI V WATER IV HEAT RECOVERY
ARWB420LAS4 / ARWB440LAS4
ARWB480LAS4

HP 42 44 48
Combination Unit ARWB420LAS4 ARWB440LAS4 ARWB480LAS4
Model Name ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
Independent Unit ARWB140LAS4 ARWB140LAS4 ARWB140LAS4
ARWB080LAS4 ARWB100LAS4 ARWB140LAS4
kW 117.6 123.2 134.4
Cooling (Rated)
Capacity Btu/h 401,700 420,800 459,000
Heating (Rated) kW 132.3 138.6 151.2
Cooling (Rated) kW 22.9 24.13 26.88
Input
Heating (Rated) kW 24.04 25.18 28.01
EER 5.14 5.11 5.00
COP Rated Capacity 5.50 5.50 5.40
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 30.1 + 28.6 + 10.7 30.1 + 28.6 + 15.8 30.1 + 28.6 + 28.6
Rated Water Flow LPM 192 + 135 + 77 192 + 135 + 96 192 + 135 + 135
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 3 (Inverter) x 3 (Inverter) x 3
Compressor Motor Output x Number W x No. 5,300 x 1 + 4,200 x 2 5,300 x 1 + 4,200 x 2 5,300 x 1 + 4,200 x 2
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 8,600 8,600 8,600
Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Refrigerant
Low Pressure Gas Pipe mm (inch) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8)
Connecting Pipes
High Pressure Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8)
40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT
Inlet A (inch)
1-1/2) (Internal Thread) 1-1/2) (Internal Thread) 1-1/2) (Internal Thread)
Water Connecting Pipes Outlet 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT
A (inch)
1-1/2) (Internal Thread) 1-1/2) (Internal Thread) 1-1/2) (Internal Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 3 (755 x 997 x 500) x 3 (755 x 997 x 500) x 3
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3
Net Weight kg x No. (140 x 1) + (127 x 2) (140 x 1) + (127 x 2) (140 x 1) + (127 x 2)
Shipping Weight kg x No. (150 x 1) + (137 x 2) (150 x 1) + (137 x 2) (150 x 1) + (137 x 2)
Sound Cooling dB(A) 60.0 60.0 60.0
Pressure Level Heating dB(A) 62.0 62.0 62.0
Sound Cooling dB(A) 72.0 72.0 74.0
Power Level Heating dB(A) 74.0 74.0 76.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 14.6 14.6 14.6
Refrigerant Factory
t-CO2eq 30.5 30.5 30.5
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 64 64 64

Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected.The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160%
~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms byISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms byISO 3741 standard.Therefore, these
values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)

100 / 101
OUTDOOR UNITS _ MULTI V WATER IV _ SPECIFICATION

MULTI V WATER IV HEAT RECOVERY


ARWB500LAS4 / ARWB540LAS4
ARWB600LAS4

HP 50 54 60
Combination Unit ARWB500LAS4 ARWB540LAS4 ARWB600LAS4
Model Name ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
Independent Unit ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
ARWB100LAS4 ARWB140LAS4 ARWB200LAS4
kW 140.0 151.2 168.0
Cooling (Rated)
Capacity Btu/h 478,100 516,000 573,300
Heating (Rated) kW 157.5 170.1 189.0
Cooling (Rated) kW 27.49 30.24 33.60
Input
Heating (Rated) kW 28.68 31.51 35.01
EER 5.09 5.00 5.00
COP Rated Capacity 5.49 5.40 5.40
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 30.1 + 30.1 + 15.8 30.1 + 28.6 + 28.6 30.1 + 30.1 + 30.1
Rated Water Flow LPM 192 + 192 + 96 192 + 192 + 135 192 + 192+ 192
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 3 (Inverter) x 3 (Inverter) x 3
Compressor Motor Output x Number W x No. 5,300 x 2 + 4,200 x 1 5,300 x 2 + 4,200 x 1 5,300 x 3
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 8,800 8,800 9,000
Liquid Pipe mm (inch) Ø19.05 (3/4) Ø19.05 (3/4) Ø19.05 (3/4)
Refrigerant
Low Pressure Gas Pipe mm (inch) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø41.3 (1-5/8)
Connecting Pipes
High Pressure Gas Pipe mm (inch) Ø34.9 (1-3/8) Ø34.9 (1-3/8) Ø34.9 (1-3/8)
40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT
Inlet A (inch)
1-1/2) (Internal Thread) 1-1/2) (Internal Thread) 1-1/2) (Internal Thread)
Water Connecting Pipes Outlet 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT 40A (PT 1-1/2) + 40A (PT 1-1/2) + 40A (PT
A (inch)
1-1/2) (Internal Thread) 1-1/2) (Internal Thread) 1-1/2) (Internal Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 3 (755 x 997 x 500) x 3 (755 x 997 x 500) x 3
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3 (804 x 1,143 x 630) x 3
Net Weight kg x No. (140 x 2) + (127 x 1) (140 x 2) + (127 x 1) 140 x 3
Shipping Weight kg x No. (150 x 2) + (137 x 1) (150 x 2) + (137 x 1) 150 x 3
Sound Cooling dB(A) 58.0 60.0 56.0
Pressure Level Heating dB(A) 63.0 62.0 62.0
Sound Cooling dB(A) 70.0 74.0 70.0
Power Level Heating dB(A) 75.0 76.0 76.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 11.8 11.8 9.0
Refrigerant Factory
t-CO2eq 24.6 24.6 18.8
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 64 64 64

Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected.The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160%
~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms byISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms byISO 3741 standard.Therefore, these
values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
MULTI V WATER IV HEAT RECOVERY
ARWB620LAS4 / ARWB640LAS4
ARWB680LAS4

HP 62 64 68
Combination Unit ARWB620LAS4 ARWB640LAS4 ARWB680LAS4
ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
Model Name ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
Independent Unit
ARWB140LAS4 ARWB140LAS4 ARWB140LAS4
ARWB080LAS4 ARWB100LAS4 ARWB140LAS4
kW 173.6 179.2 190.4
Cooling (Rated)
Capacity Btu/h 592,700 611,600 649,800
Heating (Rated) kW 195.3 201.6 214.2
Cooling (Rated) kW 34.10 35.33 38.08
Input
Heating (Rated) kW 35.71 36.85 39.68
EER 5.09 5.07 5.00
COP Rated Capacity 5.47 5.47 5.40
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure
kgf/cm2 45 45 45
Heat Exchanger Resistance
Head Loss kPa 30.1 + 30.1 + 28.6 + 10.7 30.1 + 30.1 + 28.6 + 15.8 30.1 + 30.1 + 28.6 + 28.6
Rated Water Flow LPM 192 + 192 + 135 + 77 192 + 192 + 135 + 96 192 + 192 + 135 + 135
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 4 (Inverter) x 4 (Inverter) x 4
Compressor Motor Output x Number W x No. 5,300 x 2 + 4,200 x 2 5,300 x 2 + 4,200 x 2 5,300 x 2 + 4,200 x 2
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 11,600 11,600 11,600
Liquid Pipe mm (inch) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8)
Refrigerant
Low Pressure Gas Pipe mm (inch) Ø44.5 (1-3/4) Ø44.5 (1-3/4) Ø53.98 (2-1/8)
Connecting Pipes
High Pressure Gas Pipe mm (inch) Ø41.3 (1-5/8) Ø41.3 (1-5/8) Ø44.5 (1-3/4)
40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Inlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40
(Internal Thread) (Internal Thread) (Internal Thread)
Water Connecting Pipes 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Outlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40
(Internal Thread) (Internal Thread) (Internal Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 4 (755 x 997 x 500) x 4 (755 x 997 x 500) x 4
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4
Net Weight kg x No. (140 x 2) + (127 x 2) (140 x 2) + (127 x 2) (140 x 2) + (127 x 2)
Shipping Weight kg x No. (150 x 2) + (137 x 2) (150 x 2) + (137 x 2) (150 x 2) + (137 x 2)
Sound Cooling dB(A) 61.0 61.0 61.0
Pressure Level Heating dB(A) 64.0 64.0 63.0
Sound Cooling dB(A) 73.0 73.0 75.0
Power Level Heating dB(A) 76.0 76.0 77.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 17.6 17.6 17.6
Refrigerant Factory
t-CO2eq 36.7 36.7 36.7
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 64 64 64

Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected.The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160%
~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms byISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms byISO 3741 standard.Therefore, these
values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)

102 / 103
OUTDOOR UNITS _ MULTI V WATER IV _ SPECIFICATION

MULTI V WATER IV HEAT RECOVERY


ARWB700LAS4 / ARWB740LAS4
ARWB800LAS4

HP 70 74 80
Combination Unit ARWB700LAS4 ARWB740LAS4 ARWB800LAS4
ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
Model Name ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
Independent Unit
ARWB200LAS4 ARWB200LAS4 ARWB200LAS4
ARWB100LAS4 ARWB140LAS4 ARWB200LAS4
kW 196.0 207.2 224.0
Cooling (Rated)
Capacity Btu/h 668,900 707,100 764,400
Heating (Rated) kW 220.5 233.1 252.0
Cooling (Rated) kW 38.69 41.44 44.80
Input
Heating (Rated) kW 40.35 43.18 46.68
EER 5.07 5.00 5.00
COP Rated Capacity 5.46 5.40 5.40
Color Warm Gray / Morning Gray Warm Gray / Morning Gray Warm Gray / Morning Gray
Exterior
RAL Code (Classic) RAL 7044 / RAL 7030 RAL 7044 / RAL 7030 RAL 7044 / RAL 7030
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Maximum Pressure 2
kgf/cm 45 45 45
Heat Exchanger Resistance
Head Loss kPa 30.1 + 30.1 + 30.1 + 15.8 30.1 + 30.1 + 30.1 + 28.6 30.1 + 30.1 + 30.1 + 30.1
Rated Water Flow LPM 192 + 192 + 192 + 96 192 + 192 + 192 + 135 192 + 192 + 192 + 192
Type Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll
Combination x No. (Inverter) x 4 (Inverter) x 4 (Inverter) x 4
Compressor Motor Output x Number W x No. 5,300 x 3 + 4,200 x 1 5,300 x 3 + 4,200 x 1 5,300 x 4
Oil Type FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)
Oil Charge cc 11,800 11,800 12,000
Liquid Pipe mm (inch) Ø22.2 (7/8) Ø22.2 (7/8) Ø22.2 (7/8)
Refrigerant
Low Pressure Gas Pipe mm (inch) Ø53.98 (2-1/8) Ø53.98 (2-1/8) Ø53.98 (2-1/8)
Connecting Pipes
High Pressure Gas Pipe mm (inch) Ø44.5 (1-3/4) Ø44.5 (1-3/4) Ø44.5 (1-3/4)
40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Inlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40
(Internal Thread) (Internal Thread) (Internal Thread)
Water Connecting Pipes 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2) 40A (PT 1-1/2) + 40A (PT 1-1/2)
Outlet A (inch) + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40 + 40A (PT 1-1/2) + PT40
(Internal Thread) (Internal Thread) (Internal Thread)
Drain Outlet A (inch) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread) 20A (PT 3/4) (External Thread)
Dimensions (W x H x D) mm x No. (755 x 997 x 500) x 4 (755 x 997 x 500) x 4 (755 x 997 x 500) x 4
Dimensions (W x H x D) - Shipping mm x No. (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4 (804 x 1,143 x 630) x 4
Net Weight kg x No. (140 x 3) + (127 x 1) (140 x 3) + (127 x 1) 140 x 4
Shipping Weight kg x No. (150 x 3) + (137 x 1) (150 x 3) + (137 x 1) 150 x 4
Sound Cooling dB(A) 59.0 61.0 57.0
Pressure Level Heating dB(A) 65.0 63.0 63.0
Sound Cooling dB(A) 71.0 75.0 71.0
Power Level Heating dB(A) 77.0 77.0 77.0
No. x mm2
Communication Cable 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5 2C x 1.0 ~ 1.5
(VCTF-SB)
Refrigerant Name R410A R410A R410A
Precharged Amount in
kg 14.8 14.8 12.0
Refrigerant Factory
t-CO2eq 30.9 30.9 25.1
Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Power Supply Ø, V, Hz 3, 380-415, 50 3, 380-415, 50 3, 380-415, 50
Number of Maximum Connectable Indoor Units 64 64 64

Note
1. Maximum numbers are prepared based on assumption that all 2.2kW indoor units are connected.The numbers in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160%
~ 200%). The recommended ratio is 130%.
2. Due to our policy of innovation some specifications may be changed without notification
3. Performances are based on the following conditions
- Cooling : Indoor temp 27°C (80.6°F) DB / 19°C (66.2°F) WB, Water inlet temp 30°C (86°F)
- Heating : Indoor temp 20°C (68°F) DB, Water inlet temp 20°C (68°F)
- Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
4. Sound pressure level is measured on the rated condition in the anechoic rooms byISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms byISO 3741 standard.Therefore, these
values can be increased owing to ambient conditions during operation.
5. This product contains Fluorinated Greenhouse Gases. (R410A, GWP (Global warming potential) = 2,087.5)
6. Add an anti freeze to circulation water when outdoor unit is operating under 10°C (50°F), and change the DIP switch on main PCB. (For more information on installation section.)
NOTE

104 / 105
NOTE
NOTE

106 / 107
NOTE
NOTE

108 / 109
2021

LG Electronics Distributed by
http://www.lg.com
http://partner.lge.com