L I G H T I N G E N E R G Y & S U S TA I N A B I L I T Y
FOCUS
                                       Document how much electrical power the design will consume. Compare this to code requirements for improved lighting quality and sustainability.
                                                             WATTAGE              TOTAL WATTS PER           TOTAL WATTS USED TOTAL WATTS USED                       ACTUAL DESIGN
FIXTURE     TYPE & FAMILY         LUMEN OUTPUT               OPTIONS                  FIXTURE                   IN DESIGN     IN WAITING ROOM                      LIGHTING POWER
                                                                                                                                    ONLY                               DENSITY
          EVO6PC Cylinder
          EVO 6” LED round
                                                            120, 120-277,                                    29.5W x 49 Fixtures        29.5W x 3 Fixtures
          cylinder with pendant      250 LM                                                29.5                                                                         0.28 W/ft²
          stem mount                                          277, 347                                        1445.5 Total Watts         88.5 Total Watts                                M6 A1
          by Gotham Lighting
                                                                                                                                                                                         RESTAURANT
          BRM9L TUWH
          Linear
          Bruno LED-Dynamic
                                                                 120                       31.6              21.6W x 9 Fixtures          21.6W x 3 Fixtures             0.34 W/ft²
                                    1000 L/FT
          Tunable White                                                                                       194.4 Total Watts           64.8 Total Watts
          Suspended Linear
          by Peerless
          6100 Benno LED
          Drums Pendant
          by Winona Lighting       3539 - 6738          120V, 277V, 347V                   85.8              85.8W x 9 Fixtures          85.8W x 3 Fixtures             0.53 W/ft²
                                                                                                             16679 Total Watts            255 Total Watts
          6102 Benno LED                                                                                                                                                                 NTS
          Drums LED Wall
          Sconce                      860               120V, 277V, 347V                   32.2              32.2W x 11 Fixtures         32.2W x 0 Fixtures             1.3 W/ft²
          by Winona Lighting                                                                                  354.2 Total Watts             0 Total Watts                                LIGHTING ENERGY &
                                                                                                                                                                                         SUSTAINABILITY
 TOTAL                                                                                                        18673 Total Watts            398 Total Watts
                                                                                                                                                                                         M6
                                                                              L I G H T I N G E N E R G Y & S U S TA I N A B I L I T Y
                                                                              FOCUS
                                                                              Find out how many points your design would earn under LEED v4 ID+C Credit 2 Optimize Energy Performance and Credit 6 Interior Lighting.
              CODE REQUIREMENT                                                           OPTIMIZE LIGHTING ENERGY                                                                                       OPTIMIZE LIGHTING QUALITY
Directive: Keep within your “Lighting Energy   Intent: Achieve increasing levels of energy performance beyond the prerequisite standard to reduce environmental        Intent: Promote occupants’ productivity, comfort, and well-being by providing high-quality
Budget”                                        and economic harms associated with excessive energy use.                                                                lighting.
Reference:                                     References:                                                                                                             References:
Ohio Energy Code IECC 2012/ASHRAE              LEED v4 ID+C                                                                                                            LEED v4 ID+C
90.1-2010 (PDF in Canvas)Table 9.6.1           Energy and Atmosphere (E&A)                                                                                             Interior Environmental Quality (IEQ)
Lighting Power Densities Using the Space-      Credit 2 Optimize Energy Performance                                                                                    Credit 6 Interior Lighting
by-Space Method ANSI/ASHRAE/IESNA              Table 2. Points for percentage reduction in lighting power density
Standard 90.1-2010
Q1. What is the area of your space?            Q1. Interior Lighting Power. According to Credit 2 Optimize Energy Performance Table 2 “Points for percentage           Q1. Lighting Quality. Summarize the 8 strategies for Lighting Quality found in this credit. At
                                               reduction in lighting power density,” what are the maximum watts you can use in the design to meet each LEED            least 4 strategies are required to earn 1 point. Consider which strategies are suitable for your
A: 5168 ft2
                                               point level requirement?                                                                                                design.
                                               A: Calculate max. allowable watts for each point in the center column below:
                                                                                                                                                                                                                                                                             M6 A2
                                                                                                                                                                       A: 2, 3, 4, 5, 6, 7, 8
Referring to Table 9.6.1, which “Space Type”     Percent reduction from                Calculate max. allowable watts for points                  Points Earned        1. Use light fixtures with a luminance of   6. Furniture finishes must have surface reflectance
best describes your space?                       code max LDP. for space           0.65 watts/ft2 (reduced LPD) x ___ ft2 (space area) =                               less than 2,500 cd/m2 (45º – 90º)           no more than: 45% for work surfaces, and 50% for
                                                           type                                          ___watts                                                                                                  movable partitions.
A: Waiting Room for Restaurant
                                                                                                                                                                       2. Use light sources with a color
                                                      (0.65 watts/ft2)
                                                                                                                                                                       rendering index of 80 or higher
                                                                                                                                                                                                                                                                             RESTAURANT
                                                           10%                             0.59 watts/ft2 x 5168 ft2 = 3023 watts                        1                                                         7. 75% of the ratio of average wall surface
                                                                                                                                                                                                                   illuminance to average work plane must not exceed
                                                 Multiply max. LPD by .90
                                                                                                                                                                       3. At least 75% of the lights must be       1:10 and have surface reflectance of 60% for walls.
                                                           15%                             0.55 watts/ft2 x 5168 ft2 = 2842 watts                        2
                                                                                                                                                                       rated to last 24,000 hours
                                                 Multiply max. LPD by .85                                                                                                                                          8. 75% of the ratio of average ceiling illuminance to
                                                           20%                             0.52 watts/ft2 x 5168 ft2 = 2687 watts                        3                                                         work surface must not exceed 1:10 and have
                                                   Multiply LPD by .80                                                                                                 4. Only 25% of the lighting must be         surface reflectance of 85% for ceilings.
                                                           25%                             0.49 watts/ft2 x 5168 ft2 = 2519 watts                        4             direct overhead
                                                   Multiply LPD by .75
                                                                                                                                                                       5. 90% of the floor area must have
                                                                                                                                                                       surface reflectance no more than: 85%
                                                                                                                                                                       for ceilings, 60% for walls, and 25% for
                                                                                                                                                                       floors.
Q2. Per Table 9.6.1, what is the maximum       Q2. Interior Lighting Controls. What two types of energy-conserving lighting controls can be used to earn points        Q2. Lighting Control. What types of lighting controls are required to earn 1 point within Credit
Lighting Power Density (LPD) for this space    within Credit 2 Optimize Energy Performance? Is this type of lighting control suitable for your design?                 6 Interior Lighting? Is this type of lighting control suitable for your design?
type?
                                               A: Yes, these controls work for my design                                                                               A: All types are suitable but only (3) seen in the waiting area
A: 0.65 watts/ft2
                                                   1. Daylighting Controls (1 point)                                                                                        1. Multizone control systems that enable occupants to adjust the lighting to meet group
                                                   2. Occupancy Sensor Lighting Controls (1 point)                                                                             needs with at least three lighting levels
                                                                                                                                                                            2. Lighting for any projection wall must be separately controlled.
                                                                                                                                                                            3. Switches must be located in the same space as the controlled luminaires. A person
                                                                                                                                                                               operating the controls must have a direct line of sight to the controls.
Q3. What maximum total number of watts         Q3. How many LEED points does your project earn within Credit 2 Optimize Energy Performance and why?                    Q3. How many LEED points does your project earn within Credit 6 Interior Lighting?
does this represent for the space?
                                               A: My allowable lighting power is 3359 watts                                                                            A:
A: 5168 ft2 x 0.65 watts/ft2 = 3359 watts
                                               4 points for Interior Lighting Power. My project’s actual lighting design uses a total of 398 watts. My project’s LPD   1 point for Interior Lighting Control. My project earned these points through switches located in     NTS
                                               is 0.08 watts/ft2. This represents a percent reduction of 88%.                                                          the same space as the controlled luminaires. Due to it being a waiting area the room will be
                                                                                                                                                                       controlled by the workers and not individual occupants.
                                               2 points for Interior Lighting Controls. My project earned these points through daylight controls given the large
                                               window exposure and occupancy sensors for when no one is waiting in the area                                            1 point for Interior Lighting Quality. My project earned these points through strategies 2-5 listed   LIGHTING ENERGY &
                                                                                                                                                                       about. All lights are LED rated with over 24000 live spans, a CRI of 80 or more, with very little
                                                                                                                                                                       reflective illuminance.
                                                                                                                                                                                                                                                                             SUSTAINABILITY
                                                                                                                                                                                                                                                                             M6.1
                                                         ELECTRICAL POWER & LIGHTING
                                                         CONTROL FLOOR PLAN
GOALS
Locate dedicated outlets, convenience outlets, and a wireless booster in the room for guests so that guests may access the internet. If any reception, office or clinical
staff work within your waiting room, also include provisions for telephone and data outlets for each workstation.
                                                                                                                                    LIGHTING ZONES
                                                                                                                                    Indicated by dashed connection
                                                                                                                                    lines
                                 Bruno           Benno                        Evo
                                                                                                                                    Type of controls
                                                                                                Benno                               Seen in pendant, can (2), & sconce lights
                                                                                                                                    1.	 Dimming
                                                                                                                                    2.	 Timer
                                                                                                                                                                                M6 B & C
                                                                                                                                    Specialty controls
                                                                                                                                    Seen in can (3) & track lighting
                           D
                                                                                                                                    3.	 Daylight sensor
                                                                                                                                    4.	 Occupancy sensor                        RESTAURANT
                                                                                                                                              Lighting Controls
                                                                                                                                         $     Switch
                                                                                                                                         $D    Dimmer Switch
                                                                                                                                               Telephone Outlet
                                                     D                              D
                                                                                                                                               Data Outlet
                                                                                                                                               Wireless Signal
                                                                                                                                               Booster
                                                                                                                                               Sensors
                                                                                                                                        * all data outlets conform
                                                                                                                                        with ADA requirements for
                                                                                                                                        reach
                                                                                                                                    DESIGN CRITERIA
                                                                                                                                    Given the nature of the space
                                                                                                                                    controls are very important to set          NTS
                                                                                                                                    moods and portray appropriate
                                                                                                                                    light quantity. The waiting area
                                                                                                                                    is theoretically the most used              REFLECTED CEILING
                                                                                                                                    area so it requires proper lighting         PLAN
                                                                                                                                    for the host and occupants.
                                                                                                                                    Although the area is spastically
                                                                                                                                    used in which sensors will help
                                                                                                                                    control the electrical output.              M6.3