Electrical Layout Blueprint

This document provides an electrical panel diagram with circuit breaker labels and amperages. It shows a main 60 amp circuit breaker feeding 16 downstream circuits protected by circuit breakers ranging from 20 to 30 amps, including lighting, air conditioning, range, and washer/dryer circuits.

Uploaded by

Ed dela Pena
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
225 views1 page

Electrical Layout Blueprint

This document provides an electrical panel diagram with circuit breaker labels and amperages. It shows a main 60 amp circuit breaker feeding 16 downstream circuits protected by circuit breakers ranging from 20 to 30 amps, including lighting, air conditioning, range, and washer/dryer circuits.

Uploaded by

Ed dela Pena
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

GENERAL NOTES 60 AT, 2P

MAIN CIRCUIT BREAKER

A B C A B C

20A 20A
LIGHTING CKT 1 CKT 2 LIGHTING

1 1 20A 30A
PB REF
LIGHTING CKT 3 CKT 4 ACU

LINE OF OVERHEAD CABINET


REF RANGE
ACU
20A 20A
RANGE
KS
C.O. CKT 5 CKT 6 C.O. (REF)

DN
30A 30A
C.O. (RANGE) CKT 7 CKT 8 C.O. (WH)
30A 30A
UP
ACU CKT 9 CKT 10 ACU
20A 20A
2 2 C.O. CKT 11 CKT 12 C.O.
30A 30A
C.O. (WH) CKT 13 CKT 14 ACU
ACU
20A 20A

LCD
C.O. CKT 15 CKT 16 SPARE

LCD
3 ACU 3 ACU
SC
GROUND WIRE

5 PANEL BOX DETAIL


E-01 SCALE N.T.S.

POWER LAYOUT POWER LAYOUT


1 GROUND FLOOR PLAN 2 SECOND FLOOR PLAN
E-01 SCALE 1:100 MTS. E-01 SCALE 1:100 MTS.

A B C A B C

1 PB
1

LINE OF OVERHEAD CABINET

LINE OF WARDROBE
S S
S2w
S
6 TEL/CATV RISER DIAGRAM
E-01 SCALE N.T.S.
S POWER SERVICE
2
2-8.0MM TW
S2w S ENTRANCE CAP
2
220 V, 60 Hz, 1- 8.0MM TW
2 LINE OF WARDROBE
2 PVC CONDUIT

LINE OF WARDROBE

LINE OF WARDROBE
S S S 2 ELEVATED TYPE HOUSE CONNECTION FOR FLOOD PURPOSES
2-8.0MM TW
2
1- 8.0MM TW

PVC CONDUIT

S
3 3
KILOWATT-HOUR
METER

M
PANEL BOARD
60A SAFETY
SWITCH

1800
1500
HOUSE FLOOR FIN.
SIDE WALK LEVEL NATURAL GROUND LEVEL

LIGHTING LAYOUT LIGHTING LAYOUT


3 GROUND FLOOR PLAN 4 SECOND FLOOR PLAN
E-01 SCALE 1:100 MTS. E-01 SCALE 1:100 MTS.
7 POWER RISER DIAGRAM
E-01 SCALE N.T.S.

SEAL DESIGNER STRUCTURAL ENGR. PLUMB./FIRE PRO ENGR. ELECTRICAL ENGR. MECHANICAL ENGR. PROJECT TITLE & LOCATION OWNER SHEET NO.
REPUBLIC ACT 9266

NOTE: THIS DRAWING, AS AN INSTRUMENT OF SERVICE


IS THE PROPERTY OF : CARTER T. CHOA AND AS SUCH
MUST NOT BE REPRODUCED OR COPIED IN PART OR IN
WHOLE WITHOUT THEIR PERMISSION ALL DRAWINGS ARE
ARCHITECT ENGINEER ENGINEER ENGINEER ENGINEER E
TO BE RETURNED WHEN NO LONGER IN USE, 22284 236-843-360
REPUBLIC ACT 9266.

CD-0862391 02-18-15