PANEL: LPP CABLE: 2 - 22.0 mm2 + G 8.
0 mm2 THHN MAIN: 90AT, 100AF, 2P, 240V, 20 kAIC, MCCM
PHASE: 1 CONDUIT: RSC, 32 mm DIA. ENCLOSURE: NEMA 1
VOLTS: 230V COUNTING: SURFACE
RATING OF LOAD SIZE OF CONDUCTOR SIZE OF CIRCUIT PROTECTION
NO. OF
CKT NO. CIRCUIT DESCRIPTION COLOR CODE CONDUIT
OUTLETS SQ. MM SQ. MM
HP ɸ VOLTS WATTS AMPERES IN MM Ø AT AF kAIC POLE TYPE
THHN THHN(G)
1 7 LIGHTING OUTLET 1 230 700 3.04 2 - 2.0 1R,1BK 20 15 100 10 2 B - On
2 6 LIGHTING OUTLET 1 230 600 2.61 2 - 2.0 1R,1BK 20 15 100 10 2 B - On
3 7 LIGHTING OUTLET 1 230 700 3.04 2 - 2.0 1R,1BK 20 15 100 10 2 B - On
4 6 LIGHTING OUTLET 1 230 600 2.61 2 - 2.0 1R,1BK 20 15 100 10 2 B - On
5 5 CONVENIENCE OUTLET 1 230 900 3.91 2 - 3.5 + 1 - 3.5 1R,1BK,1G 20 20 100 10 2 B - On
6 5 CONVENIENCE OUTLET 1 230 900 3.91 2 - 3.5 + 1 - 3.5 1R,1BK,1G 20 20 100 10 2 B - On
7 5 CONVENIENCE OUTLET 1 230 900 3.91 2 - 3.5 + 1 - 3.5 1R,1BK,1G 20 20 100 10 2 B - On
8 6 CONVENIENCE OUTLET 1 230 1080 4.70 2 - 3.5 + 1 - 3.5 1R,1BK,1G 20 20 100 10 2 B - On
9 1 REFRIGERATOR 1 230 2000 8.70 2 - 3.5 + 1 - 3.5 1R,1BK,1G 20 20 100 10 2 B - On
10 1 ELECTRIC RANGE 1 230 1500 6.52 2 - 3.5 + 1 - 3.5 1R,1BK,1G 20 20 100 10 2 B - On
11 1 WASHING MACHINE 1 230 2000 8.70 2 - 3.5 + 1 - 3.5 1R,1BK,1G 20 20 100 10 2 B - On
12 1 AIR-CONDITIONING UNIT 1.34 1 230 1000 4.35 2 - 3.5 + 1 - 3.5 1R,1BK,1G 20 20 100 10 2 B - On
13 1 AIR-CONDITIONING UNIT 1.34 1 230 1000 4.35 2 - 3.5 + 1 - 3.5 1R,1BK,1G 20 20 100 10 2 B - On
14 1 AIR-CONDITIONING UNIT 1.34 1 230 1000 4.35 2 - 3.5 + 1 - 3.5 1R,1BK,1G 20 20 100 10 2 B - On
15 1 AIR-CONDITIONING UNIT 1.34 1 230 1000 4.35 2 - 3.5 + 1 - 3.5 1R,1BK,1G 20 20 100 10 2 B - On
16 1 AIR-CONDITIONING UNIT 1.34 1 230 1000 4.35 2 - 3.5 + 1 - 3.5 1R,1BK,1G 20 20 100 10 2 B - On
17 SPARE
18 SPARE
TOTAL 230 16880 73.39 2 - 22.0 + 1 - 8.0 1R,1BK,G 32
FEEDER AND CURRENT PROTECTION COMPUTATION:
NOTE: Im = 8.0 Amperes , DF = 80% [ 73.39 + ( 25% x Im )] DF
IFL = = 60.31 AMPS.
G - Means Ground Wire
1R - Color RED USE:
1BK - Color BLACK
1G - Color GREEN FEEDER: 2 - 22.0 mm2 THHN + 1 - 8.0 mm2 THHN IN 32 mm Ø RSC
[ 73.39 + ( 250% x Im )] DF
ICB = = 74.71 AMPS.
This Electrical Design is good only for the above connected loads. USE:
Any additional electrical load connection in the future is prohibited,
Except redesign of electrical load system will be done. MAIN: 90AT , 100AF, 2P, 240V, 20 kAIC, CB
ACOSTA, KURT FRANCIS H. SCHEDULE OF LOADS JANUARY 05, 2020
201810657 BSCE 3-1 PROPOSED TWO-STOREY HOUSE ENGR. JOE RIENZI BENCITO
E-7