TERRACE TERRACE
BEDROOM 3
SLIDING DOOR
SLIDING DOOR
LIVING ROOM FAMILY ROOM
GYM
BEDROOM 4
SLIDING DOOR
HALL WAY
UP
TERRACE
TERRACE
SLIDING DOOR
SLIDING DOOR SLIDING DOOR
SLIDING DOOR
DOWN
UP
UP DOWN
WATER
SLIDING DOOR
REFILLING
STATION
RO
FIXED GLASS
SKID PRE-TREATMENT
KITCHEN
TERRACE
MASTER'S BEDROOM
TERRACE
CO
POST TREATMENT
SOURCE & DINING
TANK GYM
RECEIVING AREA
UP UP ZUMBA AREA
C.R.
BEDROOM 1 BEDROOM 2
PRODUCT
LANDING LANDING
DISPENSING
TANK
REF
CO CO CO
TO SEPTIC
TO CANAL CO CO CO CO
TANK
TO SEPTIC
FIXED GLASS SLIDING DOOR
TANK
GROUND FLOOR PLAN TO SEPTIC
TERRACE TANK TERRACE
TYPICAL 2ND & 3RD FLOOR PLAN 4TH FLOOR PLAN
SEWER AND WATER LINE LAYOUT
SCALE NTS
KS
ST
3.60
VTR
1.00 0.10 1.00 0.10 1.40
LAV
LAV
CO
SPACED @ 0.30mts
OCBW DS
CO CO CO CO WC
MANHOLE MANHOLE MANHOLE
0.60
1.30
OUTLET INLET
PLUMBING SYMBOLS
SCALE NTS
0.20 0.20 0.20
0.60 0.60 0.60
PLAN
0.10
GENERAL NOTES:
CO CO CO CO
MANHOLE MANHOLE MANHOLE
SPACED @ 1. ALL SANITARY WORKS INCLUDE HEREIN SHALL BE EXECUTED ACCORDING TO THE PROVISIONS OF
0.10
0.30
0.30mts OCBW THE NATIONAL BUILDING CODE OF THE PHILIPPINES, AND ITS IMPLEMENTING RULES AND
0.10
REGULATIONS.
0.70
INLET
2. ALL PLUMBING WORKS SHALL BE DONE UNDER THE DIRECT SUPERVISION OF A LICENSED SANITARY
ENGINEER.
OUTLET
REBARS SPACED @ 3. ALL PIPES SHALL BE INSTALLED AS INDICATED, ANY RELOCATION REQUIRED FOR PROPER
1.80
0.60mts OC
EXECUTION OF OTHER TRADES SHALL BE PRIOR APPROVAL OF THE ARCHITECT/AND OR THE
DIGESTIVE ENGINEER.
DIGESTIVE REBARS PLACED EVERY @ 3
LEACHING CHAMBER
0.95
LAYER OF CHAMBER
CHAMBER 4. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL LOCATION, DEPTH AND INVERT
CHAMBER ELEVATION OF EXISTING PIPES AND STRUCTURES AS VERIFIED BY THE CONTRACTOR.
5. ALL SLOPES FOR HORIZONTAL DRAINAGE SHALL MAINTAIN 2% AS MINIMUM, UNLESS OTHERWISE
NOTED.
0.15
6. SIZE OF WATER SUPPLY PIPES TO FIXTURES SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S
SPACED @ 0.25mts
0.40 0.40 0.40 0.40 NSTRUCTON.
7. ALL FIXTURES SHALL BE VENTED, UNLESS OTHERWISE NOTED.
SECTION
8. THE CONTRACTOR SHALL VERFY ALL EXISTING UTILITIES AT SITE AND COORDINATE THE WORKS
WITH THE SEWER EFFLUENT DISPOSAL AND WATERLINE SERVICE CONNECTING POINT.
9. REFER TO TECHNICAL SPECIFICATION FOR DETAILED MATERIAL AND EQUIPMENT.
10. ALL STORM DRAIN PIPES SHALL LEAD TO THE NEAREST CITY/MUNICIPALITY DRAINAGE SYSTEMS.
SEPTIC TANK DETAIL PLUMBING NOTES
SCALE 1:25mts
SCALE NTS
SEWER AND WATER LINE ISOMETRY
SCALE NTS
CONSULTANT: RESTRICTION: PROJECT TITLE: DESIGNED &DRAWN BY: REVISIONS: PROJECT OWNER: SHEET CONTENT: SHEET No.
<NAME OF DESIGNER>
CONSTRUCTION OF 4-STOREY RESIDENTIAL DRAWN BY
BUILDING W/ COMMERCIAL P
SANITARY ENGINEER AS SHOWN
PRC NO. (AMENDED PLAN) ISSUED TO
FROILAN S. FLORENDO, JR. 7 7
PTR NO.
DATE ISSUED: PLACE ISSUED: LOCATION: BARIQUIR, NAGUILIAN LA UNION <NAME OF OWNER> LOCATION: BARIQIUR, NAGUILIAN LA UNION