Solenoid Valves For Actuator Control - 3/2 or 5/2 Valves - NAMUR Interface-Spool Design

This document provides specifications for solenoid valves for actuator control including 3/2 or 5/2 valves with NAMUR interface and spool design. It lists port sizes, orifice flow factors, admissible differential pressure ranges, fluid and operating temperature ranges, reference numbers, power consumption, weights, dimensions, and notes for various valve models. The valves have anodized aluminum bodies with NAMUR interface and spool design and are suitable for use between -40 to 80 degrees Celsius.

Uploaded by

Zoran Jankov
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
280 views1 page

Solenoid Valves For Actuator Control - 3/2 or 5/2 Valves - NAMUR Interface-Spool Design

This document provides specifications for solenoid valves for actuator control including 3/2 or 5/2 valves with NAMUR interface and spool design. It lists port sizes, orifice flow factors, admissible differential pressure ranges, fluid and operating temperature ranges, reference numbers, power consumption, weights, dimensions, and notes for various valve models. The valves have anodized aluminum bodies with NAMUR interface and spool design and are suitable for use between -40 to 80 degrees Celsius.

Uploaded by

Zoran Jankov
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Solenoid valves for actuator control - 3/2 or 5/2 valves - NAMUR interface-Spool design

Port size Orifice Flow Admissible Fluid Seat Reference numbers Power Wt. El. Part Dim
(mm) factors differential temp. disc consumption (g) Group ref.
OR
(L/min) pressure bar °C (W) *
Min Max Min Max Global valve Valve reference no.
G Qn DC AC reference Housing Coil DC AC
4 2
Pilot operated

Anod. aluminium body/NAMUR interface - Spool design 5 13

1/4 - 1/8 4 600 2 10 10 -25 80 NBR 7341NAKBJNM0 341N31 2995 481865 9 8 510 2 211
4 600 2 10 10 -25 80 NBR 4270 481000 8 8 620 2
4 600 2 10 10 -40 65 NBR 7341NAKBJPM0 341N3108 1 2995 481865 9 8 510 2 211
4 600 2 10 10 -40 65 NBR 4270 481000 8 8 620 2
4 600 2 10 - -25 80 NBR 7341NAKBJNL2 341N3180 2995 482740 1.6 - 510 6 211
Pilot operated 4 2

Anod. aluminium body/NAMUR interface - Spool design 5 1 3

1/4 - 1/8 4 400 2 10 10 -25 80 NBR 7341NAKBHN90 341N3190 - 483580.01 2 0.4 - 640 7 211
Pilot operated 4 2

Anod. aluminium body/NAMUR interface - Spool design 5 13

1/4 - 1/8 4 600 2 10 10 -25 80 NBR 7341NAKBJN1D 341N31001D - 483250 8 8 1520 5 7753
4 600 2 10 10 -40 65 NBR 7341NAKBJP1D 341N31081D - 483250 8 8 1520 5 7753
Solenoid and external 4 2

pressure supply

Anod. aluminium body/NAMUR interface - Spool design 14 5 13

1/4 - 1/8 4 600 2 10 10 -40 65 NBR 7441NAKBJPM0 441N3108 1 2995 481865 9 8 510 2 211
4 600 2 10 10 -40 65 NBR 4270 481000 8 8 620 2
Table continued on page 262
Notes:
* See Electrical Parts Group table at end of section
1. Operates with low temperatures down to -40 deg. C
2. Other coil-housing available: 488650.01, 488660.01, 4888670.01 (refer to electrical parts at end of this section)

260 Parker Lucifer SA


Fluid Control Division Europe
Parker Lucifer SA
260
CH-1227 Carouge-Genève
Fluid Control Division Europe
CH-1227 Carouge-Genève