0% found this document useful (0 votes)
93 views2 pages

Watercooler Spec Sheet

The document describes a two station wall mount water cooler that is vandal-resistant and provides barrier-free access. It has specifications for its construction, cooling system, dimensions, and certifications to meet accessibility standards.

Uploaded by

James Loewen
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
93 views2 pages

Watercooler Spec Sheet

The document describes a two station wall mount water cooler that is vandal-resistant and provides barrier-free access. It has specifications for its construction, cooling system, dimensions, and certifications to meet accessibility standards.

Uploaded by

James Loewen
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Two Station Wall Mount Water Cooler

®
Vandal-Resistant, Barrier-Free Access
SP E C I F I C AT I O N S Model VRCTL8SC
GENERAL
Self-contained, double wall hung electric refrigerated, water
cooler. Vandal-resistant unit for use in high demand locations
where vandalism may occur. Rated for indoor or outdoor use.
Stainless steel construction provides vandal-resistant
enclosure. Optional perforated stainless steel louver screen-
ing prevents objects from being inserted into cooler. Flow
regulator provides constant stream from 20 to 105 psi water
pressure. Heavy duty push button control is vandal-resistant.
ADA COMPLIANT
These Water Coolers comply with the requirements of A.D.A.
(Americans with Disabilities Act) when properly installed. Also
meets the guidelines for children’s environments providing
the floor to orifice height is 30" or less and proper clear floor
space is provided for parallel approach. (Based on
Architectural and Transportation Barriers Compliance Board
final ruling.) Check Local and State Codes. Model VRCTL8SC

NO LEAD DESIGN Temperature Control: Enclosed adjustable thermostat is


These Water Coolers are certified to be lead-free as defined factory preset. Requires no adjustment other than for altitude
by the Safe Drinking Water Act. Elkay Water Coolers are man- requirements. Easily accessible.
ufactured with a waterway system utilizing copper compo-
nents and completely lead-free materials. These waterways CONSTRUCTION
have no lead because all lead materials, such as leaded Frame: alvanized structural steel chassis supports fountain
brass, have been removed. All joints are brazed using silver top and cabinet panels.
solder only. No lead solder is permitted. A strainer with an
easily cleanable screen is provided to allow trapping and con- Cololer Top: Series 300 one piece stainless steel top,
venient removal of waterborne particulate of 140 microns and polished to a uniform Elkay bright luster finish. Basin has
larger prior to their entry into the water cooler. embossed bubbler pad.
CAPACITIES CHART Vandal-resistant bubbler: Heavy duty, one piece construc-
tion. Keyed into position to prevent rotation. Meets UL
**GPH of 50°F requirements and all sanitary codes.
Drinking Water
Ship. Cabinet: Cabinet design allows for flush to wall mounting. No
Room Temperature °F Full Glass Wt.
Model Volt./ Base 70°F 80°F 90°F Rated Load Filler Filter Louver Lbs. recess space is required. Includes bottom cover plate
Number Hertz Rate (21°C) (27°C) (32°C) Watts Amps Option Option Screens (Kg.) fastened with vandal-resistant screws.
120V/
VRCTL8SC 7.8 9.4 8.6 7.8 575 5 No Yes Yes 94 Color Selection: Stainless steel furnished as standard.
60Hz
220- ALSO AVAILABLE
VRCTL8S2JOC 240V/ 6.5 7.9 7.2 6.5 575 2.5 No Yes Yes 94 Model VRCTLFR8SC Same as model above, which
50Hz
220-
includes frost resistant heating element. Tested to 32°F (0°C)
VRCTL8S3JOC 240V/ 7.5 9.4 8.6 7.8 575 2.5 No Yes Yes 94 with no wind. Specify for areas where the temperature will
60Hz occasionally drop to freezing for a short period of time. (Glass
filler not available). Model VRCTLFRDDSC also available.
VRCTLDDSC – – – – – – – No Yes Yes 56
Model VRCTLSC8SC Same as VRCTL8S with perforated
**Based on 80°F (27°C) inlet water temperature. stainless steel louvers screening prevents objects from being
Rated watts shown are based on operational (run) time, in accordance with A.R.I. inserted into coolers. VRCTLSCDDSC also available.
Standard 1010 conditions. Specific applications will determine the actual watts
consumed per hour. Watts consumed will be based on number of people Protected by Elkay’s 5 Year Limited Warranty on the refrig-
served per hour (usage), ambient temperatures, and inlet water temperature. eration system of the unit.
COOLING SYSTEM Elkay Pressure-Type Water Coolers are designed to operate
Motor Compressor: Hermetically sealed, reciprocating type, on 20 psi (138 KPa) to 105 psi (724 KPa) supply line pressure.
120 Volt/60 Hz, single phase or 220-240 Volt/50 Hz or 60 Hz, If inlet pressure is above 105 psi (724 KPa), a pressure
two phase. Sealed-in lifetime oil supply. Equipped with elec- regulator must be installed in the supply line. Any damage
tric cord and three prong molded rubber plug. caused by reason of connecting this product to supply line
pressures lower than 20 psi (138 KPa) or higher than 105 psi
Condenser: Fan cooled, copper tube with aluminum fins. Fan (724 KPa) is not covered by the warranty.
motor is permanently lubricated.
STANDARDS
Cooling Unit: Combination tube-tank type. Tube portion is
continuous coil of copper tubing. Fully insulated with EPS Elkay Electric Air Cooled Water Coolers are listed
foam which meets Underwriters Laboratories Inc. require- by Underwriters Laboratories Inc. and comply with
ments for self extinguishing material. both Canadian and U.S. requirements.
Refrigeration Control: Refrigerant HFC-134a is controlled These units comply with A.R.I. Standard 1010.
by accurately calibrated capillary tube for positively trouble-
free operation. This cooler is certified by WQA to lead-free compliance including
NSF/ANSI 61 and 372.

In keeping with our policy of continuing product improvement, Elkay reserves the right to change This specification describes an Elkay product with design, quality and functional benefits to the
product specifications without notice. Please visit elkayusa.com for most current version. user. When making a comparison of other producers’ offerings, be certain these features are not
overlooked.

Elkay 2222 Camden Court Printed in U.S.A.


Oak Brook, IL 60523 ©2013 Elkay
elkayusa.com
(Rev. 1/13)
Two Station Wall Mount Water Cooler
Vandal-Resistant, Barrier-Free Access ®

Model VRCTL8SC ROUGH- IN DIM ENSIONS


®

INSTALLER PLEASE NOTE:


1/4" O.D. TUBE 3/8" O.D. TUBE CONNECT IMPORTANT
WATER INLET COLD WATER SUPPLY BUILDING WATER
TO COOLER INLET THIS WATER COOLER HAS BEEN DESIGNED AND BUILT TO PROVIDE WATER TO THE USER
WHICH HAS NOT BEEN ALTERED BY MATERIALS IN THE COOLER WATERWAYS. THE
GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING
BUT MAY ALSO OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE
NOTE: WATERFLOW SERVICE STOP ELECTRICAL FEEDBACK INTO A WATER COOLER CREATING AN ELECTROLYSIS WHICH
DIRECTION (NOT FURNISHED) CREATES A METALLIC TASTE OR CAUSES AN INCREASE IN THE METAL CONTENT OF THE
WATER. THIS CONDITION IS AVOIDABLE BY INSTALLING THE COOLER USING THE PROPER
MATERIALS AS SHOWN BELOW.
A

TUBE

O
TTAC
SIMPLY
PER
ATIO
NO
B

H IN

FQU
IC
KC
ON
N
RELEASE TUBE
PULLING IT OUT HELPS TO
PUSHING TUBE IN BEFORE
C

TOPOSITION
TUBE
A
TO RELEASE TUBE
PUSH
PUSH
EC
IS SECURED
TFITTIN
GS
ININ COLLET
NOTICE
OPERATION OF QUICK CONNECT FITTINGS THIS WATER COOLER MUST BE CONNECTED TO THE WATER SUPPLY USING A DIELECTRIC
COUPLING. THE COOLER IS FURNISHED WITH A NON-METALLIC STRAINER WHICH MEETS
SIMPLY PUSH IN TUBE IS SECURED PUSH IN COLLET
TUBE TO ATTACH IN POSITION TO RELEASE TUBE
THIS REQUIREMENT. THE DRAIN TRAP WHICH IS PROVIDED BY THE INSTALLER SHOULD ALSO
BE PLASTIC TO COMPLETELY ISOLATE THE COOLER FROM THE BUILDING PLUMBING SYSTEM.

A B C MINIMUM 40 PSI SUPPLY LINE PRESSURE REQUIRED IN SPECIAL CIRCUMSTANCES WHEN BOTH
SIDES OF BILEVEL ARE IN USE SIMULTANEOUSLY TO ENSURE ADEQUATE STREAM HEIGHT. DOES
PUSHING TUBE IN BEFORE
NOT APPLY TO NON-REFRIGERATED UNITS.
PULLING IT OUT HELPS TO
RELEASE TUBE

*F
A
=7/L16 "RDA
B
OLR
TH
OLE
SF
O
R F
A
S T
E
NIREQUIREMENT
N
GUN ITTO W
E
=
D
=
C
=
IN
E
1 -E
S
E U
C E
IP
"T
RCAO
P
L
SE
UR
V
PE
N
T
L
YIL
(3 A
T
IIR
I)IS
W O
N
B
E
R Y
E
CM
A
E
SINET
DA
IB
N
O .A
IN
G
XL
6".(152mm
)(M
IN
.)CLE
A
R
A N
C
EF
RO
MC
A
B
IN
ETLO U
VERST
OW
AL.
B
A=
=R
R3 ”1
E(/7
C
C
2
O
O6T
R
M
M
m
m
M
M
A
E
E
P
N
N
D
E
)N
M
A
X
D
E
O
D
D
T
F
L
O
IM
U
W
U
R
N
C
A
M
O
A
T
ET
U
R
H
E
O
N
T
F
S
U
D
F
O
R
R
O
M
P
L
Y W
WA
S
LT
A
LO
CA.E
TIO
U
O
NT
.LE
S
HT
1
U-1
T O/2
F"O
.A
VD
.V
L D
R
EA
(NIN
O.F
T U
R
NIS
H
E
D)T
O
AC
E
PT3/8"O
.D
.UNP
LA
T
EDC
OPE
RT
U
B
E.
LE
G
EN D
FINISHED REDUCE FLOOR HEIGHT BY 3" FOR INSTALLATION OF CHILDRENS ADA COOLER
(127mm)
5" (114mm) (511mm) (313mm)
(518mm)
20-3/8" (127mm)
5"(254mm)
10" 4-1/2"
(89mm) 20-1/8"
(351mm)
13-7/8" (*27" 12-5/16"
686mm)
(62mm) 3-1/2"B(476mm)
(638mm)
18-3/4"
25-1/8" (173mm)
6-3/4"
(121mm)
(952mm) 2-7/16" HEIGHT
ORIFICE
F 32-15/16"
(837mm) 4-3/4"
37-1/2" C
F (38mm) 1-1/2" L E
C A HEIGHT RIM (203mm)
8"
E C L (810mm)
HEIGHT
D (1003mm) 31-7/8"
(166mm)
6-1/2" (35mm) ORIFICE
39-1/2"
(10 HOLES) (146mm) (35mm)
1-3/8"1-3/8" (146mm)
5/16" (146mm)(35mm)
(35mm)
1-3/8" 5-3/4"
1-3/8" (8mm)
(146mm) 5-3/4"(67mm) 2-5/8" (473mm)
5-3/4" 5-3/4" HANGER
(459mm)
18-1/16" BRACKET
18-5/8"

18-1/16"
(459mm)
5-3/4" 5-3/4" HANGER BRACKET 18-5/8"
(146mm) (146mm) (473mm)
1-3/8" 1-3/8"
5/16" (8mm) (35mm) (35mm) 5-3/4" 5-3/4" 2-5/8"
(10 HOLES) (146mm) (146mm) (67mm)
1-3/8" 1-3/8"
(35mm) (35mm)
6-1/2" 39-1/2"
(166mm) (1003mm)
ORIFICE
D HEIGHT
CL
E 31-7/8"
E (810mm)
RIM 8"
CL HEIGHT (203mm)
A
F 1-1/2"
(38mm)
37-1/2" 32-15/16" C
(952mm) F (837mm)
ORIFICE
2-7/16" HEIGHT 4-3/4"
(62mm) (121mm)
18-3/4" 25-1/8"
6-3/4"
3-1/2" B (476mm) (638mm)
20-3/8" 5" 10" (173mm)
(89mm) * 27"
(518mm) (127mm) (254mm) 13-7/8"
4-1/2" (351mm) (686mm) 12-5/16"
(114mm) 20-1/8"
(511mm) (313mm)
5"
(127mm)
FINISHED FLOOR

REDUCE HEIGHT BY 3" FOR INSTALLATION OF CHILDRENS ADA COOLER

LEGEND
A = RECOMMENDED WATER SUPPLY LOCATION. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8" O.D. UNPLATED COPPER TUBE.
3” (76mm) MAXIMUM OUT FROM WALL.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2" O.D. DRAIN.
C = 1-1/2" TRAP NOT FURNISHED
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX.
E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
F = 7/16" BOLT HOLES FOR FASTENING UNIT TO WALL.
*ADA REQUIREMENT

Elkay 2222 Camden Court Printed in U.S.A.


Oak Brook, IL 60523 ©2013 Elkay
(Rev. 1/13) elkayusa.com

You might also like