Wall Mount Water Cooler
Air Cooled Wall mount
SPECIFICATIONS Models EWA(8,14,16,20)(N,S)3YJOSA
GENERAL RATED FOR INDOOR USE ONLY
ONLY AVAILABLE FOR SAUDI ARABIA
Self-contained, electric refrigerated, wall hung water cooler. Capacity of
50°F drinking water, based upon 80°F inlet water and 90°F ambient.
Non-pressurized tank system is standard. Non-pressurized water tank
is located after bubbler valve, so that tank is subject to line pressure
only when valve button is pressed.Unit shall be lead-free design
which is certified to NSF/ANSI 61 and 372 and meets Federal and State
low-lead requirements.
Unit shall comply with ASME A 112.19.3 / CSA B45.4.
STANDARD FEATURES
• Removable front panel offers easy accessibility to interior
• Extra deep basin minimizes splashing; with integral drain
• Exclusive Flexi-Guard® Safety bubbler
• Cooler Panel Finish options: Impact-resistant vinyl coating or Stainless Steel
• Rated for Indoor use
COOLING SYSTEM
• Compressor: Hermetically sealed, reciprocating type, 220V, 60 Hz single CONSTRUCTION
phase. Sealed-in lifetime lubrication. • Stainless Steel basin with integral drain
• Condenser: Fan cooled, copper tube with aluminum fins.Fan motor is • Galvanized structural steel cooler chassis provides structural
permanently lubricated. integrity
• Cooling Unit: Combination tube-tank type. Tube portion is continuous coil of • Cooler cabinet available as Almond or Stainless Steel Panels.
copper tubing. Fully insulated with EPS foam which meets Underwriters • Exclusive Flexi-Guard® Safety Bubbler utilizes an infused
Laboratories Inc. Requirements for self extinguishing material. anti-microbial pliable polyester elastomer to prevent accidental
• Refrigerant Control: Refrigerant R134a is controlled by accurately calibrated mouth injuries. Flexes on impact.
capillary tube. • Cabinet design allows for flush to wall mounting
• Temperature Control: Easily accessible enclosed adjustable thermostat
is factory preset. Requires no adjustment other than for altitude
requirements. Warranty: 5 year limited warranty on the unit’s refrigeration
system. Electrical components and water system are warranted for
12 months from date of installation or 18 months from factory shipment,
whichever date falls first.
CAPACITIES CHART
Tested by:
SASO 1062
(SASO/IEC
Approx. NSF/ANSI
Voltage / Chilling** F.L. Rated 60335-1) &
Model Ship 61 and 372
Hertz Capacity Amps Watts SASO/IEC
Wt. Certified
60335-2-89
Compliant
EWA8S3YJOSA 220V / 60Hz 8.4 GPH 4.0 370 69 • •
EWA14S3YJOSA 220V / 60Hz 14.9 GPH 7.2 665 72 • •
EWA14N3YJOSA 220V / 60Hz 14.9 GPH 7.2 665 72 • •
EWA16N3YJOSA 220V / 60Hz 17.1 GPH 5.5 510 76 • •
EWA16S3YJOSA 220V / 60Hz 17.1 GPH 5.5 510 76 • •
EWA20N3YJOSA 220V / 60Hz 21.5 GPH 7.2 665 74 • •
EWA20S3YJOSA 220V / 60Hz 21.5 GPH 7.2 665 74 • •
`*Color code of (N) Almond (S) Stainless Steel cooler wrapper.
**Based on 80°F inlet water & 90°F ambient air temp for 50°F chilled drinking water. This specification describes an Elkay product with design, quality and functional
benefits to the user. When making a comparison of other producer’s offerings,
be certain these features are not overlooked.
In keeping with our policy of continuing product improvement, 2222 Camden Court © 2017 Elkay
Elkay reserves the right to change specification without notice. Oak Brook, IL 60523 SPEC00278 (09/2017)
Please visit elkay.com for the most current version. 630-572-3192
elkay.com
Wall Mount Water Cooler
Air Cooled Wall mount
Models EWA(8,14,16,20)(N,S)3YJOSA ROUGH-IN DIMENSIONS
Open space rough-in design permits new installation or replacement of existing RATED FOR INDOOR USE ONLY
fountains and coolers with this Elkay cooler when rough-in is within the outline shown. ONLY AVAILABLE FOR SAUDI ARABIA
IMPORTANT! INSTALLER PLEASE NOTE: NOTICE
This water cooler has been designed and built to provide water to the user which has This water cooler must be connected to the water supply using a dielectric coupling.
not been altered by materials in the cooler waterways. The cooler is furnished with a non-metallic strainer which meets this requirement.
The drain trap, which is provided by the installer, should also be plastic to completely
The grounding of electrical equipment such as telephone, computers, etc to water isolate the cooler from the building plumbing system.
lines is a common procedure. This grounding may be in the building or occur away
from the building. This grounding can cause electrical feedback into a water cooler
creating an electrolysis which creates a metallic taste or causes an increase in the
metal content of the water. This condition is avoidable by installing the cooler using
the proper materials as shown below.
SIDE VIEW
FRONT VIEW
Job Name: ____________________________________
Model: _______________________ Qty. ____________
Contact: ______________________________________
Approval Signature: _____________________________
Notes:
2222 Camden Court Printed in U.S.A.
Oak Brook, IL 60523 © 2017 Elkay
630-572-3192
elkay.com