BlueSolar Grid Inverter
BlueSolar Grid Inverter 1500 2000 2800 4000 5000
GRID OUTPUT (AC)
Nominal output power 1500W 2000W 2800W 4000W 5000W
Maximum output power 1650W 2200W 3000W 4400W 5500W
Nominal output current 6.52A 8.7A 12A 17.5A 22A
Maximum output current 7.2A 9.5A 13A 19A 24A
Maximum fuse protection 16A 16A 16A 25A 25A
Harmonic distortion of output
<3% at nominal power <5% at 50% power
current
Nominal AC output voltage 220V - 230V - 240V
Power factor >0,99% at nominal power
Operating AC voltage range 190-260V
Nominal AC frequency 50Hz
Operating AC frequency range 45.5-54.5Hz
Internal consumption at night <0,1W
Short circuit proof Yes
SOLAR INPUT (DC)
Maximum Input voltage 450V 500V 500V 550V 550V
Input Voltage MPPT range 110-430V 110-480V 110-480V 110-530V 110-530V
Maximum input current 9A 10A 13A 18A 20A
Maximum input power 1750W 2280W 3160W 4500W 5200W
Number of MPPT trackers 1 1 1 1 1
Number of strings 1 1 2 4 4
Start-up power 7W 7W 7W 10W 10W
Ground fault monitoring RCMU (residual current monitoring unit)
Reverse polarity protection Yes, with short circuit diode
EFFICIENCY
Maximum efficiency 95.5% 96.4% 96.4% 97.6% 97.8%
European standard efficiency 94.5% 95.4% 95.5% 96.7% 96.9%
GENERAL
Topology Transformerless
Communication port RS232
Operating temperature range -20°C to 60°C (automatic power limit in case of internal over temperature)
Nominal power temperature
-20°C to 55°C
range
Storage temperature range -20°C to 70°C
Maximum operating altitude 2000 m (5% derating at 4000 m)
Cooling method Natural convection
Relative humidity Max 95%
ENCLOSURE
Protection degree IP54
DC connectors MC4 (Multi Contact 4mm)
Weight (kg) 14.8 kg 14.8 kg 14.8 kg 20.7 kg 20.7 kg
Dimensions (hxwxd, mm)) 376x415x125 376x415x125 376x415x125 368x475x195 368x475x195
STANDARDS
Safety EN 50178
EMC, Emission EN 61000-6-3
EMC, Immunity EN 61000-6-2
EMC, Harmonics and Flicker EN 61000-3-2, EN 61000-3-3
Automatic Grid Disconnection VDE 0126-1-1 (2006)