0% found this document useful (0 votes)
142 views1 page

Slickline Trigger Overview

Our slickline triggers enable operators to perforate, set plugs, dump/bail, cut tubing and perform other downhole operations using standard and RF safe detonators and igniters. The triggers focus on safety with up to four primary safeties and simple operating procedures. They can detonate most standard resistorized detonators and igniters, and some include features to record pressure and temperature during perforating sequences.

Uploaded by

Susin Lim
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
142 views1 page

Slickline Trigger Overview

Our slickline triggers enable operators to perforate, set plugs, dump/bail, cut tubing and perform other downhole operations using standard and RF safe detonators and igniters. The triggers focus on safety with up to four primary safeties and simple operating procedures. They can detonate most standard resistorized detonators and igniters, and some include features to record pressure and temperature during perforating sequences.

Uploaded by

Susin Lim
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Slickline Triggers

& Perforators
Our Slickline Triggers enable Slickline Operators to Perforate, Set
Plugs, Dump/Bail, Cut Tubing and Other Operations that use Standard
51 Ohm Detonators, Igniters as well as a variety of RF Safe
Detonators.
Our Slickline Triggers are centered around Safety and Simple
Operating Procedures.

Call or email Today for more Information


SAFETIES / Controls / Benefits
Up to Four (4) Primary Safeties to Safely Initiate downhole
operations
Some Triggers record Pressure & Temperature before, during and
after the perforation sequence with its Fast and Slow Sampling
Modes
Running Gear to protect the tools from shock
Audible signal to indicate tool operation and status

Detonates most standard Resistorized Detonators and Igniters

Can Trigger some Hydrostatic Setting Tools

Operating Temperature 32°F to 302°F (0°C to 150°C) Standard


350°F (177°C) Extended
Outside Diameter 1.38 in. (3.5 cm) Nominal
Maximum Pressure 15,000 psi (103,000 kPa) Standard
20,000 psi (137,895 kPa) Extended

You might also like