Vibration Transducers Series SLD100 with Top Entry

A B

The vibration transducers series SLD100 are piezo-electric


accelero­meters of compression type with built-in electronics, SLD1XX B- XXX Cable 46105-L / 46106-L
designed for vibration monitoring of industrial machinery.
The transducer is mounted against a smooth, flat surface
on the machine. The electrical signal is isolated from the
transducer housing. The transducer is connected via a
twisted pair cable with 2 pin connector. In moist environ-
ment, use the sealed connector with integrated measuring
Sleeve Protection tube
cable SPM 46105-L / 46106-L together with cable protection 15716 81385
tube SPM 81385. The SLD144 transducer is also available
in a version that allows temperature measurement with the
online system Intellinova Parallel EN, see TD-562. Part Frequency Sensitivity * Bias
number range (±1dB) (typical)
Technical specifications SLD 121 2 –1000 Hz 1.2 mV/m/s2 = 12 mV/g 6 –9 V (8 V)
Transverse sensitivity: max. 10%
SLD122 2 –5000 Hz 4 mV/m/s2 = 40 mV/g 6 –9 V (8 V)
Base strain sensitivity: 0.01 m / s2 / µ strain typical
SLD144 2 –10 000 Hz 10 mV/m/s2 = 100 mV/g 10–13 V (12 V)
Linear frequency range: 2 Hz to 10 kHz (± 1 dB)
* Individual value given on the calibration chart.
Max. peak acceleration: 600 m / s2 = 60 g
Settling time: 3 sec
M6=5.0
Temperature range: ­– 40 °C to +125 °C
UNF=5.5
(– 40 °F to +257 °F) M8=6.9 min. 16 t
Power requirements: 24 V, 2 to 5 mA M10=8.6

Isolation: case isolated, > 10 Mohm


min. 12

Casing: stainless acid proof steel Sandvik


min. 10
max. 0.7

1802, EN:1.4523
Sealing: IP66/67
Thread (t): M6x1.0, M8 x 1.25, M10 x 1.5 or Mounting Tools
UNF 1/4"-28
81027 Holder for counterbore
Torque limit: 10 Nm (7.4 lbf . ft) 81057 Counterbore, diameter 20 mm
Weight: 110 grams (4 oz) 81030 Pilot for M6 or UNF 1/4"-28
Connection: 2 pin connector, MIL-C-5015 style 81031 Pilot for M8
81033 Pilot for M10
Cable length: max. 100 m (328 ft)
(cable capacitance 210 pF/m) To drill the mounting hole, use drill bit 5.0 mm (M6), 6.9 mm
(M8), 8.6 mm (M10) or 5.5 mm (UNF 1/4"-28). Torque the
transducer with a 24 mm torque wrench.

ARTICLE NO: SLD1X X B - X X X


A B C
A. Part number See table
B. Connection B = 2 pin connector MIL-C-5015
C. Thread (t) M6, M8, M10 or UNF

SERIAL NO: XX XX XXX


Year Week Number

SPM Instrument AB • Box 504 • SE-645 25 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • info@spminstrument.se • www.spminstrument.com ISO 9001 certified. © Copyright SPM 2018-10. TD-506 B Rev.1