NHOU
EE
R
SE
G
Hadar 7110 Hadar 7110
For irrigation, propagation and micro-climate
Application in horticulture, viticulture, orchards, greenhouses,
nurseries and landscape areas
• Bayonet coupling
• Modular construction for simple use and modification
• Wide range of wetted patterns with 9 different inserts
• 11 color-coded nozzles with flow rates from 23 to 333 l/h
• Excellent water distribution
• LPD (Leakage Prevention Device)
Technical data
Recommended working pressure: 1.5 - 3.0 bar
Diameter coverage: 1.7 - 11.0 m
Filtration:
for nozzle 0.8 - 1.2 mm: 120 mesh, 130 µ
for nozzle 1.3 mm and up: 80 mesh, 200 µ
4
Hadar 7110
Wetted diameter (m) at 2.0 bar
Wetted Diameter (m)
Nozzle Nozzle Flow Mist Small Extra-range Half-circle Mini-range Medium- Extra- Inverted
size colour rate sprayer sprayer & insect- (180˚) rotor range range rotor*
mm l/h proof sprayer sprayer 40L rotor rotor
0.8 Black 33 2.0 2.2
0.9 Gray 41 2.1 2.3 2.4 6.0
1.0 Purple 50 2.3 2.4 3.0 6.6 8.4
1.1 Red 61 2.4 2.6 3.2 7.0 8.5
1.2 Orange 75 2.6 2.8 3.6 7.5 9.0
1.3 Green 87 3.0 2.9 3.6 3.0 8.5 9.5
1.4 Blue 103 3.3 3.1 3.6 3.1 9.4 10.0
1.6 Yellow 128 3.6 3.0 3.7 3.3 9.6 10.2
1.8 Bright Green 166 4.1 3.0 3.8 3.4 10.2 10.6
2.0 White 199 4.4 3.2 3.9 3.5 10.4 11.0
2.3 Brown 265 5.4 4.2 3.7 10.6
*Tested at 2.0 m above ground
7110/98
Inverted rotor with LPD
Performance table 7110 Inverted rotor at 2 bar pressure
Flow Diameter Precipitation (mm/h) spacing (m)
Nozzle Nozzle rate
mm colour l/h m 3x3 3x4 3x5 4x4 4x5 4x6 5x5 5x6 6x6
1.3 Green 87 9.5 8.9 6.7 5.3 5.0 4.0 3.2
1.4 Blue 103 10.0 6.4 5.1 4.9 4.3 4.1 3.6
1.6 Yellow 128 10.2 7.4 6.0 5.7 5.0 4.8 5.0 4.3 4.0 3.3
1.8 Bright green 166 10.6 9.0 7.2 6.9 6.0 5.8 6.0 5.1 4.8 4.0
2.0 White 199 11.0 10.5 8.4 8.0 7.0 6.7 7.0 6.0 5.6 4.7
Tested at 2.0 m above ground
Colour code - Distribution uniformity
CU < 85% CU = 85-88% CU = 89-92% CU > 93%
Mist sprayer for propagation 7110 mist sprayer
4.0 mm inserted base
Spacing on line: 1.0 m
Spacing between laterals:
Two laterals for 1.4 - 1.6 m table width
Single lateral for 1.2 m table width
LPD
Working pressure: Leakage
Preventor Device
PE pipe: 3.0 - 5.0 bar
PVC pipe: 3.0 - 10.0 bar
Max. pressure with LPD: 5.0 bar