Model S-20 High Performance Pressure Transmitter For General Industrial Applications
Model S-20 High Performance Pressure Transmitter For General Industrial Applications
Pressure Measurement
Model S-20
High Performance Pressure Transmitter
for General Industrial Applications
WIKA Datasheet S-20
Applications
■■ General industrial applications
■■ Demanding research and development applications
■■ Harsh industrial environments
Special Features
■■ Measuring ranges from 0…10 to 0…20,000 psi (0 ... 0.4
to 0 ... 1,600 bar)
■■ Non-linearity of up to 0.125 % B.F.S.L.
■■ Available output signals include 4 ... 20 mA, 0 ... 10 VDC,
1 ... 5 VDC and many others
■■ Industry standard electrical connections including
Model S-20 Pressure Transmitter
DIN 175301-803A L- connector, cables, housings and
many others
■■ Common USA and international process connections
available
Description
High quality
The model S-20 pressure transmitter is the ideal solution for The rugged design makes the model S-20 a highly reliable
customers with demanding performance requirements in transmitter that is not affected by most adverse environmental
many industrial applications. conditions. This transmitter meets most application
performance requirements when exposed to very low outdoor
It features high accuracy, a robust design and is available with temperatures, extreme shock and vibration and aggressive
an exceptional number of options that make it suitable for an media.
extremely broad range of pressure measurement applications.
. Availability
High versatility Variations of the S-20 described in this data sheet are usually
The model S-20 offers continuous measuring ranges between available with short lead times. Inventory of popular designs
0…10 psi and 0…20,000 psi (0 ... 0.4 and 0 ... 1,600 bar) in are usually available for particularly urgent requirements.
all common engineering units. Vacuum and compound ranges
are also available.
The listed pressure ranges are also available in kg/cm2, kPa and MPa.
Special measuring ranges between 0 ... 10 and 0 ... 20,000 psi ( 0.4…1600 bar) are available on request.
Special pressure ranges may have reduced long-term stability and increased temperature errors.
Overpressure limit
The overpressure limit depends on the specific sensor element used for the selected pressure range. A reduction in the
overpressure safety rating may occur depending on the specific process connection and seal selected. A higher overpressure
limit may provide a greater temperature error.
Vacuum resistance
Yes
(No damage to sensor when vacuum is applied)
Permissible load in Ω
■■ Current output (2-wire): ≤ (power supply - 7.5 V) / 0.023 A
≤ (power supply - 11.5 V) / 0.023 A (with optional settling time of 1 ms)
■■ Voltage output (3-wire): > maximum output voltage / 1 mA
■■ Ratiometric output (3-wire): > 4.5k
Voltage supply
Power supply
Maximum allowable power supply rating for cULus approval: 35 VDC (32 VDC with heavy-duty connector)
Temperature
59…77ºF (15…25ºC)
Barometric pressure
860 ... 1,060 mbar
Humidity
45 ... 75 % relative
Power supply
■■ 24 VDC
■■ 5 VDC for ratiometric output
Mounting position
Calibrated in vertical position with pressure connection facing down
Response time
Calibration temperature
15 ... 25 °C (standard)
4 °C ±5 °C
40 °C ±5 °C
60 °C ±5 °C
80 °C ±5 °C
Non-repeatability
≤ ±0.1 % of span
Temperature hysteresis
0.1 % of span at > 176 °F (80 °C)
There may be other media and ambient temperature limitations depending upon the sealing material used with the process
connection and the specific electrical connection selected.
For restrictions see "Process connections, sealings" and "Electrical connections".
Ambient temperature [°C]
Service life
100 million load cycles (10 million load cycles for measuring ranges > 7,500 psi /600 bar)
Available connections
*6 or 12 mm enlarged pressure port is only available for measuring ranges up to and including 0 ... 500 psi (0 ... 40 bar).
Sealing rings
Process connection per Copper Stainless steel NBR FKM
-40 ... +125 °C -40 ... +125 °C -20 ... +100 °C -15 ... +125 °C
EN 837 Standard Option - -
DIN 3852-E - - Standard Option
ISO 228 Standard Option - -
-
SAE J514 E - Standard Option
Available connections
Electrical connection Ingress Wire Cable ∅ Cable maximum permissible
protection cross-sec- material temperature
tion
L-connector DIN 175301-803 A 1) IP 65 - - - -30 ... +100 °C
L-connector DIN 175301-803 C 1) IP 65 - - - -30 ... +100 °C
Circular connector M12 x 1 (4-pin) 1) IP 67 - - - -30 ... +100 °C
Circular connector M12 x 1 (4-pin, metallic) IP 67 - - - -40 ... +125 °C (cULus: +85 °C)
Bayonet connector (6-pin) IP 67 - - - -40 ... +125 °C
Field case IP 6K9K - - - -25 ... +100 °C
Heavy-duty connector 2) IP 68 - - - -40 ... +125 °C
Cable outlet IP 67 1) IP 67 3 x 0.34 mm2 5.5 mm PUR -30 ... +100 °C
Cable outlet ½ NPT conduit IP 67 6 x 0.35 mm2 6.1 mm PUR -30 ... +100 °C (cULus: +90 °C)
Cable outlet IP 68 IP 68 6 x 0.35 mm2 6.1 mm PUR -30 ... +125 °C (cULus: +90 °C)
Cable outlet IP 68, FEP IP 68 6 x 0.39 mm2 5.8 mm FEP -40 ... +125 °C (cULus: +105 °C)
Cable outlet IP 6K9K IP 6K9K 6 x 0.35 mm2 6.1 mm PUR -30 ... +125 °C (cULus: +90 °C)
1) Customer zero point adjustment available as an option.
2) max. DC 32 V with cULus approval
Cable lengths of 6 ft, 15 ft, 2 m or 5 m are available, other cable lengths on request.
U+ 1 1 U+ 1 1
U- 2 2 U- 2 2
S+ - 3 S+ - 3
Shield (option) 4 4 Shield Case Case
U+ 1 1 U+ 1 1
U- 2 2 U- 3 3
S+ - 3 S+ - 4
Shield (option) 4 4 Shield (option) Case Case
U+ A A U+ 1 1
U- B B U- 2 2
S+ - C S+ - 3
Shield Case Case Shield 5 5
Electrical protection
The electrical protection measures below do not apply to ratiometric output signals.
■■ Short-circuit protection: S+ vs. U-
■■ Reverse polarity protection: U+ vs. U-
■■ Overvoltage protection: 40 VDC
■■ Insulation voltage: 750 VDC
Wetted parts
■■ Relative measuring ranges:
- Measuring ranges ≤ 150 psi / 10 bar: 316L
- Measuring ranges > 150 psi / 10 bar: 316L + 13-8 PH
■■ Absolute pressure measuring ranges:
- Measuring ranges ≤ 10,000 psi / 1,000 bar: ASTM 630 and 13-8 PH
- Measuring ranges > 10,000 psi / 1,000 bar: 316L + 13-8 PH
■■ Sealing materials: see "Process connections"
Non-wetted parts
■■ Case: 316 Ti
■■ Zero point adjustment ring: PBT/PET GF30
■■ Electrical connections:
L-connector DIN 175301-803 A: PBT/PET GF30
L-connector DIN 175301-803 C: PBT/PET GF30
Circular connector M12 x 1 (4-pin): PBT/PET GF30
Circular connector M12 x 1 (4-pin, metallic): 316L
Bayonet connector (6-pin) 316L + Al
Field case: 316L, 316Ti
Heavy-duty connector: 316L
Cable outlet IP 67: PA66
Cable outlet ½ NPT conduit: 316L
Cable outlet IP 68: 316L
Cable outlet IP 68, FEP: 316L
Cable outlet IP 6K9K: 316L
Elastomer sealing: oly FKM possible, max. -15 ... +60 °C and max. 30 bar measuring range.
EMC directive
2004/108/EC, EN 61326 emission (group 1, class B) and interference immunity (industrial application)
EM field
30 V/m (80 ... 1,000 MHz)
RoHS conformity
Directive 2002/95/EC
Certificates (optional)
Available certificates
2.2 test report State-of-the-art manufacturing
Wetted metallic parts
Confirmation of the class and indication accuracy
3.1 inspection certificate Wetted metallic parts
Wetted metallic parts with suppliers' certificate
Confirmation of the class and indication accuracy
List of single measured values
DKD/DAkkS calibration certificate
Scope of delivery
Test report
■■ Non-linearity 0.5 % (B.F.S.L.) 3 points
■■ Non-linearity 0.25 % (B.F.S.L.) 5 points
■■ Non-linearity 0.125 % (B.F.S.L.) 5 points
Packaging
Individual packaging (standard)
Multiple packaging (up to 20 pieces)
Instrument labeling
WIKA laser-etched label (standard)
Customer-specific label on request
with L-connector DIN 175301-803 A with L-connector DIN 175301-803 C with bayonet connector (6-pin)
with circular connector M12 x 1 (4-pin) with circular connector M12 x 1 with heavy-duty connector
(4-pin, metallic)
with field case with cable outlet IP 68, FEP, IP 6K9K with cable outlet ½ NPT conduit
G L1 G L1 G L1
G¼A 14 G⅛B 10 7/16-20 UNF BOSS 12.06
G½A 17 9/16-18 UNF BOSS 12.85
M14 x 1.5 14
G L1 G D1 L1 L2 L3 G D1 L1 L2
7/16-20 UNF J514 sealing cone 74° 15 G ¼ B female 25 20 13 10 ¼ NPT female 25 20 14
G L1 G L1
⅛ NPT 10 G¼B 13
¼ NPT 13 G½B 20
½ NPT 19 G⅜B 16
PT ¼ 13 M12 x 1.5 15
PT ½ 19 M20 x 1.5 20
PT ⅜ 15
R¼ 13
R½ 19
R⅜ 15
For information on tapped holes and welding sockets, see Technical information IN 00.14 at www.wika.com.
Mating connector
Designation Order number
without cable with 2 m cable with 5 m cable with 2 m cable, shielded
L-connector DIN 175301-803 A
■■ with gland, metric 11427567 11225793 11250186 2242656
■■ with gland, conduit 11022485 - - -
L-connector DIN 175301-803 C 1439081 11225823 11250194 -
Circular connector M12 x 1 (4-pin)
■■ straight - 11250780 11250259 14056584
■■ angled - 11250798 11250232 -
Ordering information
Model / Measuring range / Overpressure limit / Output signal / Non-linearity / Calibration temperature / Zero point adjustment
/ Process connection / Pressure channel / Sealing / Electrical connection / Assembly / Cable length / Shielding / Certificates /
Packaging / Instrument labeling / Accessories and spare parts
© 2013 WIKA Alexander Wiegand SE & Co. KG, all rights reserved.
The specifications given in this document represent the state of engineering at the time of publishing.
We reserve the right to make modifications to the specifications and materials.
WIKA Instrument, LP
1000 Wiegand Boulevard
Lawrenceville, GA 30043-5868
Tel: 888-WIKA-USA • 770-513-8200
Fax: 770-338-5118
E-Mail: info@wika.com
www.wika.com