0% found this document useful (0 votes)
174 views2 pages

Pentair Structural FRP L

FRP vessels are made of polyester or chemical-resistant vinylester and are suitable for residential and light commercial water treatment applications. They offer flexibility and easy handling/installation. Warranties range from 2-10 years depending on the vessel size and application. Vessels are available in standard sizes and openings and can withstand pressures up to 150 psi and temperatures up to 120°F (150°F for vinylester).

Uploaded by

member1000
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
174 views2 pages

Pentair Structural FRP L

FRP vessels are made of polyester or chemical-resistant vinylester and are suitable for residential and light commercial water treatment applications. They offer flexibility and easy handling/installation. Warranties range from 2-10 years depending on the vessel size and application. Vessels are available in standard sizes and openings and can withstand pressures up to 150 psi and temperatures up to 120°F (150°F for vinylester).

Uploaded by

member1000
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Lenntech

info@lenntech.com Tel. +31-152-610-900 FRP


FRP Vessels www.lenntech.com Fax. +31-152-616-289

Material of construction Y3 X
Material:
residential and light Polyester, Vinylester
Available inlets:
commercial water See chart
H1
treatment applications
Operating parameters
that require flexibility. Maximum operating
pressure:
150 psi Y1
Improve your water treatment
Maximum operating
system with Structural FRP vessels. temperature:
120° F Polyester
Easy to handle and install, FRP 150° F Vinylester

vessels are available in standard


Design parameters –
polyester or chemical-resistant Pentair
C1 L2
Safety factor:
vinylester construction depending 4:1 (Minimum burst D L1
on your needs. at 600 psi)
Cycle test:
250,000 cycles
Exclusive warranties apply as follows: without leakage

• 10 years on 6"-13" vessels used for Design parameters –


softener/filtration applications NSF
Safety factor: Y2
• 5 years on 14"-16" vessels used for
4:1 (Minimum burst
softener/filtration applications at 600 psi)
• 2 years for all vinylester vessels used Cycle test:
100,000 cycles H2
for deionization applications without leakage

Z C1
Ext. L2
Base
W

Standard Vessel Openings


Nominal Diameter Top Bottom Sidewall Dome
6˝-13˝ – 10 years from date of
manufacture Inches mm X Z Y1 and Y2 Y3
14˝-16˝ – 5 years from date of 6 152 2 1/2" – 8 NPSM 1" or 2 1/2" 3/4" 3/4"
manufacture 7 178 2 1/2" – 8 NPSM 1" or 2 1/2" 3/4" 3/4"
8 203 2 1/2" – 8 NPSM 1" or 2 1/2" 3/4" or 1" 3/4"
All FRP tanks are warranted to be free from 9 229 2 1/2" – 8 NPSM 1" or 2 1/2" 3/4" or 1" 1 1/4"
defects in materials and workmanship for a period 10 254 2 1/2" – 8 NPSM 1", 2 1/2" or 4" 3/4" or 1" 1 1/4"
or 4" – 8 UN
of 5/10 years from the date of manufacture (see
12 305 2 1/2" – 8 NPSM 2 1/2" or 4" 3/4" or 1" 1 1/4"
above) if the vessel is operated within the pre- or 4" – 8 UN
scribed pressure and temperature ratings stated on 13 330 2 1/2" – 8 NPSM 3/4" or 1" 1 1/4"
2 1/2" or 4"
the tank label. or 4" – 8 UN
14 356 4" – 8 UN 4" or 6" 3/4" – 1 1/2" 1 1/4"
16 406 4" – 8 UN or 4" or 6" 1", 1 1/2" or 2" 1 1/4"
6" – 8 UN

Color Options: BL - Blue BK - Black NA - Natural


FRP
FRP Vessels Specifications
A
Overall Height
Material of construction Y3 Size Capacity Cubic Tank Diameter Tank Height L1 Std. Base L2 Ext. Base Dimensions
The ideal choice for X
(Inches) Gallons Liters Feet A (In./mm) C1 (In./mm) (In./mm) (In./mm) D (In./mm) H1 (In./mm) H2 (In./mm)
Material:
residential and light Polyester, Vinylester 6 x 13 1.6 6.1 0.2 6.0 / 152 16.0 / 406 12.8 / 325 18.7 / 475 6.0 / 152 3.1 / 79 3.5 / 89
Available inlets: 6 x 18 2.3 8.7 0.3 6.0 / 152 18.0 / 457 18.1 / 460 24.0 / 610 9.4 / 239 4.1 / 104 4.5 / 114
commercial water See chart
H1 6 x 32 3.8 14.4 0.5 6.0 / 152 32.0 / 813 32.2 / 818 38.1 / 968 23.4 / 594 4.1 / 104 4.5 / 114
treatment applications 6 x 35 4.4 16.7 0.6 6.0 / 152 35.0 / 889 35.1 / 892 41.0 / 1041 26.4 / 671 4.1 / 104 4.5 / 114
Operating parameters
that require flexibility. Maximum operating
7 x 22 3.5 13.3 0.5 7.0 / 178 22.0 / 559 22.2 / 564 28.0 / 711 13.1 / 333 4.9 / 124 4.1 / 104
pressure: 7 x 24 3.8 14.4 0.5 7.0 / 178 24.0 / 610 24.1 / 612 30.0 / 762 15.1 / 384 4.9 / 124 4.1 / 104
150 psi Y1
Improve your water treatment 7 x 30 4.8 18.2 0.6 7.0 / 178 30.0 / 762 30.2 / 767 36.0 / 914 21.1 / 536 4.9 / 124 4.1 / 104
Maximum operating
7 x 35 5.7 21.6 0.8 7.0 / 178 35.0 / 889 35.1 / 892 40.9 / 1039 26.0 / 660 4.9 / 124 4.1 / 104
system with Structural FRP vessels. temperature:
120° F Polyester 7 x 40 6.6 25.0 0.9 7.0 / 178 40.0 / 1016 40.2 / 1021 46.0 / 1168 31.1 / 790 4.9 / 124 4.1 / 104
Easy to handle and install, FRP 150° F Vinylester 7 x 44 7.3 27.6 1.0 7.0 / 178 44.0 / 1118 44.4 / 1128 50.2 / 1275 35.3 / 897 4.9 / 124 4.1 / 104
vessels are available in standard 8 x 17 3.1 11.7 0.4 8.0 / 203 17.0 / 432 17.2 / 437 23.0 / 584 7.2 / 183 5.3 / 135 4.4 / 112
Design parameters –
polyester or chemical-resistant Pentair 8 x 22 4.3 16.3 0.6 8.0 / 203 22.0 / 559 22.8 / 579 28.6 / 726 12.8 / 325 5.3 / 135 4.4 / 112
C1 L2
Safety factor: 8 x 24 4.6 17.4 0.6 8.0 / 203 24.0 / 610 24.3 / 617 30.1 / 765 14.3 / 363 5.3 / 135 4.4 / 112
vinylester construction depending 4:1 (Minimum burst D L1 8 x 30 6.0 22.7 0.8 8.0 / 203 30.0 / 762 30.2 / 767 36.0 / 914 20.2 / 513 5.3 / 135 4.4 / 112
on your needs. at 600 psi)
8 x 35 7.1 26.9 0.9 8.0 / 203 35.0 / 889 35.2 / 894 41.0 / 1041 25.2 / 640 5.3 / 135 4.4 / 112
Cycle test:
250,000 cycles 8 x 36 7.3 27.6 1.0 8.0 / 203 36.0 / 914 36.2 / 919 42.0 / 1067 26.2 / 665 5.3 / 135 4.4 / 112
Exclusive warranties apply as follows: without leakage 8 x 40 8.2 31.0 1.1 8.0 / 203 40.0 / 1016 40.3 / 1024 46.1 / 1171 30.3 / 770 5.3 / 135 4.4 / 112

• 10 years on 6"-13" vessels used for 8 x 44 9.1 34.4 1.2 8.0 / 203 44.0 / 1118 44.5 / 1130 50.2 / 1275 34.4 / 874 5.3 / 135 4.4 / 112
Design parameters –
softener/filtration applications NSF 9 x 35 8.8 33.3 1.2 9.0 / 229 35.0 / 889 35.3 / 897 41.0 / 1041 24.5 / 622 5.3 / 135 5.2 / 132
Safety factor: Y2
9 x 40 10.3 39.0 1.4 9.0 / 229 40.0 / 1016 40.3 / 1024 46.0 / 1168 29.5 / 749 5.3 / 135 5.2 / 132
• 5 years on 14"-36" vessels used for
4:1 (Minimum burst 9 x 48 12.5 47.3 1.7 9.0 / 229 48.0 / 1219 48.3 / 1227 54.0 / 1372 37.5 / 953 5.3 / 135 5.2 / 132
softener/filtration applications at 600 psi)
10 x 19 5.1 19.3 0.7 10.0 / 254 19.0 / 483 19.3 / 490 24.8 / 630 8.0 / 203 5.8 / 147 5.2 / 132
• 2 years for all vinylester vessels used Cycle test:
100,000 cycles H2 10 x 30 8.5 32.2 1.1 10.0 / 254 30.0 / 762 30.4 / 772 36.0 / 914 19.3 / 490 5.8 / 147 5.2 / 132
for deionization applications without leakage 10 x 35 10.4 39.4 1.4 10.0 / 254 35.0 / 889 35.2 / 894 40.7 / 1034 23.8 / 605 5.9 / 150 5.2 / 132
10 x 40 12.1 45.8 1.6 10.0 / 254 40.0 / 1016 40.3 / 1024 45.8 / 1163 28.9 / 734 5.9 / 150 5.2 / 132
10 x 42 12.7 48.1 1.7 10.0 / 254 42.0 / 1067 42.3 / 1074 47.8 / 1214 31.0 / 787 5.8 / 147 5.2 / 132
Z C1 10 x 44 13.4 51.0 1.8 10.0 / 254 44.0 / 1118 44.3 / 1125 49.9 / 1267 33.1 / 841 5.8 / 147 5.2 / 132
Ext. L2
Base 10 x 47 14.4 55.0 1.9 10.0 / 254 47.0 / 1194 47.3 / 1201 52.8 / 1341 36.0 / 914 5.8 / 147 5.2 / 132
W
10 x 54 16.7 63.0 2.2 10.0 / 254 54.0 / 1372 54.3 / 1379 59.8 / 1519 43.0 / 1092 5.8 / 147 5.2 / 132
12 x 29 14.2 53.7 1.9 12.0 / 305 29.0 / 737 29.1 / 739 34.2 / 869 15.4 / 391 6.6 / 168 6.4 / 163
Standard Vessel Openings 12 x 38 18.8 71.2 2.5 12.0 / 305 38.0 / 965 39.0 / 991 43.9 / 1115 25.1 / 638 6.6 / 168 6.4 / 163
Nominal Diameter Top Bottom Sidewall Dome 12 x 48 23.4 89.0 3.1 12.0 / 305 48.0 / 1219 48.9 / 1242 53.8 / 1367 35.0 / 889 6.6 / 168 6.4 / 163
6˝-13˝ – 10 years from date of
manufacture Inches mm X Z Y1 and Y2 Y3
13 x 54 27.6 105.0 3.7 13.0 / 330 54.0 / 1372 54.9 / 1394 59.8 / 1519 35.6 / 904 9.1 / 231 9.3 / 236
14˝-16˝ – 5 years from date of 6 152 2 1/2" – 8 NPSM 1" or 2 1/2" 3/4" 3/4"
manufacture 7 178 2 1/2" – 8 NPSM 1" or 2 1/2" 3/4" 3/4" 14 x 65 39.7 150.3 5.3 14.0 / 356 65.0 / 1651 65.7 / 1669 70.5 / 1791 43.0 / 1092 10.8 / 274 11.1 / 282
8 203 2 1/2" – 8 NPSM 1" or 2 1/2" 3/4" or 1" 3/4"
16 x 23 14.5 55.0 1.9 16.0 / 406 23.0 / 584 24.7 / 627 28.8 / 732 See Factory 11.6 / 295 13.4 / 340
All FRP tanks are warranted to be free from 9 229 2 1/2" – 8 NPSM 1" or 2 1/2" 3/4" or 1" 1 1/4"
defects in materials and workmanship for a period 10 254 2 1/2" – 8 NPSM 1", 2 1/2" or 4" 3/4" or 1" 1 1/4" 16 x 33 22.4 56.0 3.0 16.0 / 406 33.0 / 838 34.6 / 879 38.8 / 966 9.7 / 246 11.6 / 295 13.4 / 340
or 4" – 8 UN
of 5/10 years from the date of manufacture (see 16 x 45 31.7 120.0 4.2 16.0 / 406 45.0 / 1143 46.5 / 1181 50.6 / 1285 21.6 / 549 11.6 / 295 13.4 / 340
12 305 2 1/2" – 8 NPSM 2 1/2" or 4" 3/4" or 1" 1 1/4"
above) if the vessel is operated within the pre- or 4" – 8 UN
scribed pressure and temperature ratings stated on 16 x 58 42.0 159.0 5.6 16.0 / 406 58.0 / 1473 59.6 / 1514 63.7 / 1618 34.6 / 878 11.6 / 295 13.4 / 340
13 330 2 1/2" – 8 NPSM 2 1/2" or 4" 3/4" or 1" 1 1/4"
the tank label. or 4" – 8 UN 16 x 65 48.3 182.8 6.4 16.0 / 406 65.0 / 1651 65.9 / 1674 71.1 / 1806 41.7 / 1059 11.5 / 292 13.4 / 340
14 356 4" – 8 UN 4" or 6" 3/4" – 1 1/2" 1 1/4"
Not covered by this warranty is damage resulting 16 406 4" – 8 UN or 4" or 6" 1", 1 1/2" or 2" 1 1/4"
from freezing, external impact, chemical attack 6" – 8 UN
from liquid and gasses, exposure to vacuum, natu- 21 533 4" – 8 UN or 4" or 6" 1", 1 1/2" or 2" 2"
6" – 8 UN
ral disasters, or other applications of the product
24 610 4" – 8 UN or 4" or 6" 1 1/2" or 2" 2"
beyond residential water softeners and filters. 6" – 8 UN
30 762 * 4" or 6" 1 1/2" or 2" 2"
36 914 * 4" or 6" 1 1/2" or 2" 2" Color Options: BL - Blue BK - Black NA - Natural

[6] * All 30" and 36" diameter tanks (150 psi operating ) must have one 6"-8" opening
located at either “X” or “Z” and one 4"-6" or 6"-8" opening at the other end. [7]

You might also like