FUJIFILM FCR CAPSULA XLII Specifications
Standard Components:                                                                                           Number of Stacker: 1
• FCR CAPSULA XLII Image Reader Unit (Model: CR-IR 359)
                                                                                                               Reading Gray Scale: 12 bits
• AC power cord
                                                                                                               Network: 10 Base T /100 Base TX
Other System Components:
• Optional upgrade kit for 50-micron reading with HR-V                                                         Dimensions (W ✕ D ✕ H): 590 ✕ 380 ✕ 810 mm (23” ✕ 15” ✕ 32”)
• IP cassette type CC, LC, CH
• CR Console
                                                                                                                                                                                                  Unit: mm (in.)
• Dry Imager: DRYPIX 2000, 4000, 7000
                                                                                                                               380 (15)                                      590 (23)
Supplies:
Imaging Plate:
• ST-VI: 35 ✕ 43 cm (14” ✕ 17”), 35 ✕ 35 cm (14” ✕ 14”), 10” ✕ 12”, 8” ✕ 10”,
         24 ✕ 30 cm, 18 ✕ 24 cm, 15 ✕ 30 cm
• HR-V: 24 ✕ 30 cm*, 18 ✕ 24 cm**
IP Cassette:
• Type CC: 35 ✕ 43 cm (14” ✕ 17”), 35 ✕ 35 cm (14” ✕ 14”), 10” ✕ 12”, 8” ✕ 10”,
           24 ✕ 30 cm, 18 ✕ 24 cm, 15 ✕ 30 cm
                                                                                                                                                                                                       810 (32)
• Type LC: 35.4 ✕ 124.5 cm, 35.4 ✕ 101.7 cm, 35.4 ✕ 83.7 cm, 25.2 ✕ 58 cm,
           24 ✕ 57 cm
• Type CH: 24 ✕ 30 cm*, 18 ✕ 24 cm** (For 50-micron reading with HR-V)
Time Required for IP Feed /Load:
                                                                                                                                                                                                                            FUJI COMPUTED RADIOGRAPHY
                       IP Type                                                 Required Time
      ST-VI               35 ✕ 43 cm (14” ✕ 17”)                             Approx. 58 (41) sec.
      ST-VI               35 ✕ 35 cm (14” ✕ 14”)                             Approx. 52 (38) sec.
      ST-VI                       10” ✕ 12”                                    Approx. 49 sec.                                                                                                                         FUJIFILM introduces a compact, all-in-one FCR with extremely clear
      ST-VI                       8” ✕ 10”                                     Approx. 41 sec.
      ST-VI                      24 ✕ 30 cm                                    Approx. 48 sec.                                                                                                                         and optimal imaging based upon FUJIFILM’s extensive experience.
      ST-VI                      18 ✕ 24 cm                                    Approx. 39 sec.                 Weight: 99 kg (218 lbs.)
      ST-VI                      15 ✕ 30 cm                                    Approx. 49 sec.                 Power Supply Conditions:
      HR-V                       24 ✕ 30 cm*                                   Approx. 59 sec.                  Single phase 50-60Hz
      HR-V                    18 ✕ 24 cm**                                     Approx. 51 sec.                  120-240V ±10%
• Under “Required Time” in the table above, figures in parentheses are at high-speed mode.                      5A (max)
• Image erase time on IP is directly related to the exposure made. It is assumed to be at 25mR for ST-VI and
                                                                                                               Environmental Conditions:
  600 mR for HR-V.
• The performance described above shows typical values. It varies depending on the exposure level.
                                                                                                               • Operating Conditions:
                                                                                                                 Temperature: 15-30°C
Processing Capacity                                                                                              Humidity: 40-80%RH (No dew condensation)
                       IP Type                                              Processing Capacity
                                                                                                               • Non-operating Conditions:
                                                                                                                 Temperature: 0-45°C
      ST-VI               35 ✕ 43 cm (14” ✕ 17”)                            Approx. 62 (87) IPs/hr.              Humidity: 10-90%RH (No dew condensation)
      ST-VI               35 ✕ 35 cm (14” ✕ 14”)                            Approx. 70 (94) IPs/hr.
      ST-VI                       10” ✕ 12”                                   Approx. 73 IPs/hr.
      ST-VI                       8” ✕ 10”                                    Approx. 87 IPs/hr.               IP Cassette
      ST-VI                      24 ✕ 30 cm                                   Approx. 75 IPs/hr.
      ST-VI                      18 ✕ 24 cm                                   Approx. 92 IPs/hr.
      ST-VI                      15 ✕ 30 cm                                   Approx. 73 IPs/hr.                Type CC
      HR-V                       24 ✕ 30 cm*                                  Approx. 61 IPs/hr.
      HR-V                    18 ✕ 24 cm**                                    Approx. 70 IPs/hr.
• Figures in parentheses and conditions are the same as those of “Time Required for IP Feed/Load”.
• The time required to change the cassette is assumed to be 0 (zero) seconds.
Time to Display on CR Console:
• Approx. 42 sec. in case of 35 ✕ 43 cm (ST-VI) with 100-micron reading
• Approx. 32 sec. in case of 18 ✕ 24 cm (HR-V)** with 50-micron reading
Time to Print on DRYPIX 4000 through network via CR Console:
• Approx. 145 sec. in case of 35 ✕ 43 cm (ST-VI) with 100-micron reading
• Approx. 140 sec. in case of 18 ✕ 24 cm (HR-V)** with 50-micron reading
                                                                                                                                                                      24 ✕ 30 cm cassette mounted with
Reading Specification                                                                                           Type CH                                               the cassette adapter
                                                                   Reading Specification
       Inches                 Metric               Standard Pixel-density                 High Pixel-density
                                                     High-speed mode                       Standard mode
   14” ✕ 17” (ST-VI)    35 ✕ 43 cm (ST-VI)              5 pixels/mm                         10 pixels/mm
   14” ✕ 14” (ST-VI)    35 ✕ 35 cm (ST-VI)              5 pixels/mm                         10 pixels/mm
   10” ✕ 12” (ST-VI)    24 ✕ 30 cm (ST-VI)                   –                              10 pixels/mm
   8” ✕ 10” (ST-VI)     18 ✕ 24 cm (ST-VI)                   –                              10 pixels/mm
          –             15 ✕ 30 cm (ST-VI)                   –                              10 pixels/mm
          –             24 ✕ 30 cm (HR-V)*                   –                              20 pixels/mm
          –            18 ✕ 24 cm (HR-V)**                   –                              20 pixels/mm
*Requires the optional upgrade kit and the cassette adaptor.
**Requires the optional upgrade kit.
                                                                                                                                          Specifications and PC requirements are subject to change without notice.
                                                                                                                                          All brand names or trademarks are the property of their respective owners.
                                                                                                                   Ref. No. XB-870E       (SK·09·02·F1120·F9711) Printed in Japan ©2007 FUJIFILM Corporation
                                                                                                          Worldwide, extensive experience results in                                          Image Display and Processing – CR Console
                                                                                                          confidence for FCR                                                                   The multi-function console handles all
                                                                                                          In 1981, FUJIFILM became the world first manufacuturer to successfully               complex procedures of digital X-ray
                                                                                                          digitize X-ray images with FUJIFILM Computed Radiography (FCR).                      imaging – patient ID, image reviewing,
                                                                                                          This made it possible to effectively handle diagnostic images in a digital           processing and printing, DICOM interface,
                                                                                                          format that constantly provided highly precise, stable images. FUJIFILM              and more – as well as quality assurance
                                                                                                          has leading installation experience worldwide resulting in confidence to             functions all within a single workstation.
                                                                                                          satisfy all users.
                                                                                                          Compact Frame and Vertical cassette insertion for                                   Featuring Image Intelligence™ Processing
                                                                                                          Effective Work Space                                                                                          Image Intelligence™ is an integrated set of
                                                                                                          FCR CAPSULA XLII is                                                                                           image-processing technologies that comes
                                                                                                          designed for insertion of the                                                                                 from the accumulation of over 70 years of
                                                                                                          IP cassette at an angle to                                                                                    imaging expertise. The company has
                                                                                                          ensure effective layout of the                                                       constantly delivered innovative technology and high quality images, as
                                                                                                          equipment in a working area                                                          can be seen with FNC (Flexible Noise Control) that maximally
                                                                                                          that tends to be confined.                                                           suppresses noise while leaving all effective image information intact.
                                                                                                          As a result, this model
                                                                                                          requires less installation
                                                                                                          space compared with
                                                                                                          previous horizontal-insertion                                                                                             Noise
                                                                                                          models, and therefore, offers            Previous model (XG-1)       CAPSULA XLII                                      component
                                                                                                          more installation flexibility.                                                                                         suppression
                                                                                                          Compact with High Efficiency
                                                                                                          FCR CAPSULA XLII enables extremely high throughput of up to
                                                                                                          approximately 94 IPs/hr.* and the time to display the image on the CR               Mammography applications*** (Optional)
                                                                                                          Console monitor is approximately 23 sec., in spite of its compactness.               FCR CAPSULA XLII equipped with
                                                                                                          * at 35 ✕ 35 cm size on high-speed mode
                                                                                                                                                                                               the optional capability of 50-micron
                                                                                                                                                                                               reading with the HR-V and the IP
                                                                                                                                                                                               cassette type CH can visualize more
                                                                                                          All-in-one unit for all diagnostic imaging needs                                     fine and minute structures. It is suited
                                                                                                                                                                                               for mammography applications in
                                                                                                          Three types of IP cassettes (Type CC, LC and
                                                                                                                                                                                               addition to extremities and others.
                                                                                                          CH**) can cover various imaging such as chest,
                                                                                                          lumbar spine, pantomography (15 ✕ 30cm), and
                                                                                                          extremities. Virtually all imaging requirements                                     *** In the U.S. and Canada the unit cannot be applicable to mammography. In other
                                                                                                                                                                                                  countries, the locally applicable regulations and/or guidelines should be followed.
                                                                                                          can be satisfied with the single unit.
                                                                                                          ** The optional 50-micron reading kit with HR-V necessary
                                                                                                                                                                                              Example of System Layout
       Introducing a newly upgraded FCR CAPSULA XLII designed with
                                                                                                          Easy Operations monitored on Screen
a new form and equipped with state-of-the-art functions including an optional
                                                                                                          Capable of automatically starting the IP reading and image processing
  capability of 50-micron reading with high resolution imaging plates (HR-V).                             when the IP cassette is inserted, the system is designed to complete
                                                                                                          the IP reading cycle with simple operations. Setting parameters can be
                                                                                                          changed with the buttons on the monitor screen. The screen can also
One of the FCR key components is an Imaging Plate, or IP, that is used in place of X-ray film to easily   display the status and the time remaining to complete the IP reading
digitize X-ray images. The FCR CAPSULA XLII features the IP in an unprecedented compact frame,            process for user-convenience.
as it incorporates 70 years of FUJIFILM’s extensive technology and know-how. CAPSULA, meaning
small box in Latin, has been cleverly trimmed to be smaller and lighter, boosting flexibility on                                                                                                                                                                    CR Console
installation and layout, while maintaining the specifications for a broad range of diagnostic imaging
needs from general radiography to pantomography. Plus, the optional capability of 50-micron                                                                                                                                                                 FCR CAPSULA XLII
reading with the HR-V can be utilized to visualize finer and minute structures for better diagnosis.
                                                                                                                                        Utility                       Image Reading Mode
FUJIFILM FCR CAPSULA XLII Specifications
Standard Components:                                                                                           Number of Stacker: 1
• FCR CAPSULA XLII Image Reader Unit (Model: CR-IR 359)
                                                                                                               Reading Gray Scale: 12 bits
• AC power cord
                                                                                                               Network: 10 Base T /100 Base TX
Other System Components:
• Optional upgrade kit for 50-micron reading with HR-V                                                         Dimensions (W ✕ D ✕ H): 590 ✕ 380 ✕ 810 mm (23” ✕ 15” ✕ 32”)
• IP cassette type CC, LC, CH
• CR Console
                                                                                                                                                                                                  Unit: mm (in.)
• Dry Imager: DRYPIX 2000, 4000, 7000
                                                                                                                               380 (15)                                      590 (23)
Supplies:
Imaging Plate:
• ST-VI: 35 ✕ 43 cm (14” ✕ 17”), 35 ✕ 35 cm (14” ✕ 14”), 10” ✕ 12”, 8” ✕ 10”,
         24 ✕ 30 cm, 18 ✕ 24 cm, 15 ✕ 30 cm
• HR-V: 24 ✕ 30 cm*, 18 ✕ 24 cm**
IP Cassette:
• Type CC: 35 ✕ 43 cm (14” ✕ 17”), 35 ✕ 35 cm (14” ✕ 14”), 10” ✕ 12”, 8” ✕ 10”,
           24 ✕ 30 cm, 18 ✕ 24 cm, 15 ✕ 30 cm
                                                                                                                                                                                                       810 (32)
• Type LC: 35.4 ✕ 124.5 cm, 35.4 ✕ 101.7 cm, 35.4 ✕ 83.7 cm, 25.2 ✕ 58 cm,
           24 ✕ 57 cm
• Type CH: 24 ✕ 30 cm*, 18 ✕ 24 cm** (For 50-micron reading with HR-V)
Time Required for IP Feed /Load:
                                                                                                                                                                                                                            FUJI COMPUTED RADIOGRAPHY
                       IP Type                                                 Required Time
      ST-VI               35 ✕ 43 cm (14” ✕ 17”)                             Approx. 58 (41) sec.
      ST-VI               35 ✕ 35 cm (14” ✕ 14”)                             Approx. 52 (38) sec.
      ST-VI                       10” ✕ 12”                                    Approx. 49 sec.                                                                                                                         FUJIFILM introduces a compact, all-in-one FCR with extremely clear
      ST-VI                       8” ✕ 10”                                     Approx. 41 sec.
      ST-VI                      24 ✕ 30 cm                                    Approx. 48 sec.                                                                                                                         and optimal imaging based upon FUJIFILM’s extensive experience.
      ST-VI                      18 ✕ 24 cm                                    Approx. 39 sec.                 Weight: 99 kg (218 lbs.)
      ST-VI                      15 ✕ 30 cm                                    Approx. 49 sec.                 Power Supply Conditions:
      HR-V                       24 ✕ 30 cm*                                   Approx. 59 sec.                  Single phase 50-60Hz
      HR-V                    18 ✕ 24 cm**                                     Approx. 51 sec.                  120-240V ±10%
• Under “Required Time” in the table above, figures in parentheses are at high-speed mode.                      5A (max)
• Image erase time on IP is directly related to the exposure made. It is assumed to be at 25mR for ST-VI and
                                                                                                               Environmental Conditions:
  600 mR for HR-V.
• The performance described above shows typical values. It varies depending on the exposure level.
                                                                                                               • Operating Conditions:
                                                                                                                 Temperature: 15-30°C
Processing Capacity                                                                                              Humidity: 40-80%RH (No dew condensation)
                       IP Type                                              Processing Capacity
                                                                                                               • Non-operating Conditions:
                                                                                                                 Temperature: 0-45°C
      ST-VI               35 ✕ 43 cm (14” ✕ 17”)                            Approx. 62 (87) IPs/hr.              Humidity: 10-90%RH (No dew condensation)
      ST-VI               35 ✕ 35 cm (14” ✕ 14”)                            Approx. 70 (94) IPs/hr.
      ST-VI                       10” ✕ 12”                                   Approx. 73 IPs/hr.
      ST-VI                       8” ✕ 10”                                    Approx. 87 IPs/hr.               IP Cassette
      ST-VI                      24 ✕ 30 cm                                   Approx. 75 IPs/hr.
      ST-VI                      18 ✕ 24 cm                                   Approx. 92 IPs/hr.
      ST-VI                      15 ✕ 30 cm                                   Approx. 73 IPs/hr.                Type CC
      HR-V                       24 ✕ 30 cm*                                  Approx. 61 IPs/hr.
      HR-V                    18 ✕ 24 cm**                                    Approx. 70 IPs/hr.
• Figures in parentheses and conditions are the same as those of “Time Required for IP Feed/Load”.
• The time required to change the cassette is assumed to be 0 (zero) seconds.
Time to Display on CR Console:
• Approx. 42 sec. in case of 35 ✕ 43 cm (ST-VI) with 100-micron reading
• Approx. 32 sec. in case of 18 ✕ 24 cm (HR-V)** with 50-micron reading
Time to Print on DRYPIX 4000 through network via CR Console:
• Approx. 145 sec. in case of 35 ✕ 43 cm (ST-VI) with 100-micron reading
• Approx. 140 sec. in case of 18 ✕ 24 cm (HR-V)** with 50-micron reading
                                                                                                                                                                      24 ✕ 30 cm cassette mounted with
Reading Specification                                                                                           Type CH                                               the cassette adapter
                                                                   Reading Specification
       Inches                 Metric               Standard Pixel-density                 High Pixel-density
                                                     High-speed mode                       Standard mode
   14” ✕ 17” (ST-VI)    35 ✕ 43 cm (ST-VI)              5 pixels/mm                         10 pixels/mm
   14” ✕ 14” (ST-VI)    35 ✕ 35 cm (ST-VI)              5 pixels/mm                         10 pixels/mm
   10” ✕ 12” (ST-VI)    24 ✕ 30 cm (ST-VI)                   –                              10 pixels/mm
   8” ✕ 10” (ST-VI)     18 ✕ 24 cm (ST-VI)                   –                              10 pixels/mm
          –             15 ✕ 30 cm (ST-VI)                   –                              10 pixels/mm
          –             24 ✕ 30 cm (HR-V)*                   –                              20 pixels/mm
          –            18 ✕ 24 cm (HR-V)**                   –                              20 pixels/mm
*Requires the optional upgrade kit and the cassette adaptor.
**Requires the optional upgrade kit.
                                                                                                                                          Specifications and PC requirements are subject to change without notice.
                                                                                                                                          All brand names or trademarks are the property of their respective owners.
                                                                                                                   Ref. No. XB-870E       (SK·09·02·F1120·F9711) Printed in Japan ©2007 FUJIFILM Corporation