Product Catalogue: FLEXIM - Flexible Industrial Measurement
Product Catalogue: FLEXIM - Flexible Industrial Measurement
PRODUCT CATALOGUE
                         _________
Non-intrusive flow
measurement with
FLUXUS®
 Liquids
 Gases
 Thermal energy
Non-intrusive process
analytics with PIOX® S
 Concentration
 Density
 Mass flow rate
PIOX® R
process refractometer
 Concentration
 Density
 ° Brix etc.
    Contents
    Non-intrusive flow measurement with clamp-on ultrasonic technology        4
Transmitters
Transducers
2
                                                       FLEXIM
                                       Flexible Industrial Measurement Technology
FLEXIM develops, manufactures, and sells advanced process measuring devices for industrial applications.
For more than 25 years, non-intrusive ultrasonic flow measurement has its name: FLUXUS®. The name PIOX®
stands for process analytics – non-intrusive with the PIOX® S ultrasonic analyser, wetted with the PIOX® R
transmitted light refractometer.
If it flows, FLUXUS® will measure it. Progressive process analytics with PIOX®
FLEXIM’s FLUXUS® ultrasonic flowmeters are used            Clamp-on ultrasonic technology can also be used
wherever something flows. Non-intrusive clamp-on           for process analytics through non-intrusive deter-
ultrasonic technology opens up an unrivalled wide          mination of the acoustic velocity in the medium.
range of applications. FLUXUS® reliably measures           PIOX® S ultrasonic systems really stand the test in
on very small tubes (e.g. DN 6 tubes in paint fin-         applications where wetted measuring equipment is
ishing systems) and very large pipes (e.g. DN 6500         subject to considerable wear and tear, for example
downpipes in hydropower plants).                           during concentration and mass flow measurements
                                                           of acids.
The field of application is not only limited to liquids.
FLEXIM is also particularly proud of its pioneering        Measurement of light refraction is a proven method
work carried out in transferring ultrasonic tech-          for determining concentrations. Laboratory accu-
nology to the non-intrusive flow measurement of            racy is ensured in the process with the patented
gases. Clamp-on measuring technology also covers           PIOX® R transmitted light refractometer.
an extraordinary range of applications in this area
                                                           If both measuring methods are combined, multi-
– from the recording of quantities drawn off by in-
                                                           component mixtures can also be analysed accu-
dividual pneumatic consumers in a compressed air
                                                           rately and reliably.
network, to the non-intrusive measurement of gas
quantities conveyed in a gas transmission pipeline.
                                                                                                           3
FLUXUS                                                       ®
Non-intrusive flow measurement with
clamp-on ultrasonic technology
FLUXUS® measures flow rates non-intrusively with ultrasound. Clamp-on ultrasonic transducers are simply
mounted on the outside of the pipe. The practical advantages are obvious: no wear and tear by the medium flowing
inside the pipe, no risk of liquid leakage or fugitive gas emissions, no pressure loss and, above all, unlimited plant
availability.
FLUXUS® clamp-on ultrasonic systems determine the             The non-intrusive acoustic measuring method is in-
volume flow according to the transit-time difference          ertia-free and is characterised by very high measur-
method: since the ultrasonic signal that is injected          ing dynamics in both flow directions. When combined
into the pipe is carried by the medium flowing inside,        with density measurement, the transit-time differ-
a time delay occurs between the acoustic transit time         ence measurement is suitable for determining the
both with and against the flow direction. This time           volume flow rate and mass flow rate of liquids. When
delay can be measured very accurately. The measuring          combined with pressure measurement, it is suitable
transmitter calculates the volume flow rate based             for determining the standard volume flow of gases.
on the parameters input for the pipe geometry and             A particularly practical use for the non-intrusive
the physical properties of the medium stored in the           measuring technique is the fact that the current
internal database.                                            power of liquid-based thermal consumers, e.g. heat-
                                                              ing or cooling systems, can be easily recorded.
FLUXUS® clamp-on ultrasonic systems allow for the
flow measurement of almost all liquid and gaseous             As a technology leader in clamp-on ultrasonic sys-
media – even those with increased inputs of solids and        tems, FLEXIM has developed two sensor technol-
gas (<10%) or even wet gas (LVF <5%).                         ogies for non-intrusive flow measurement: shear
                                                              wave transducers for the flow measurement of
                                                              liquids and Lamb wave transducers for the flow
                                                              measurement of gases. By means of these two tech-
                                                              nologies and the internal, automatic compensation
                                                              of varying ambient temperatures, FLEXIM ensures
                                                              maximum measuring accuracy and reliability, even
                                                              under difficult conditions.
 4
                                                           FLEXIM
                                                           Flexible Industrial Measurement
Non-intrusive clamp-on technology offers maximum           The reliability and accuracy of measuring systems
flexibility and the sophisticated electronics of FLUXUS®   depend on the quality of their manufacturing and cali-
ensure the highest degree of reliability. The measuring    bration. Consistent quality management according to
system, which consists of a transmitter and VARIOFIX       DIN ISO 9001 is absolutely essential for FLEXIM. From
transducer system, can be adapted optimally to spe-        the moment the goods arrive at the warehouse to the
cific requirements.                                        moment the finished measuring system is shipped,
                                                           operational checks are carried out at every single pro-
The product range of the FLUXUS® series covers a           duction stage and everything is documented. Paired
wide spectrum of various measuring transmitters            transducers ensure high measuring accuracy of the
and transducers, from basic devices for standard ap-       measuring systems.
plications to measuring systems for usage offshore.
It goes without saying; this also includes transmitters    Calibration is carried out on individual calibration
and transducers which can be used in potentially           equipment according to national standards. FLEXIM
explosive areas as well as in applications where a SIL2    calibrates pairs of transducers and measuring trans-
qualification is needed.                                   mitters independently of one another so that the
                                                           narrowly defined measurement uncertainties are
                                                           always observed, regardless of which transducers are
                                                           used with which measuring transmitters.
                                                                                                              5
Portable Flow Meters FLUXUS® F401 and F601
                                            FLUXUS® F401              The portable FLUXUS® F401 is a single channel meter for the flow measurement
                                            (Water)                   of water and wastewater streams (<6 % of solid / gas content by volume). It is
                                                                      equipped with IP68 transducers and housed in an IP67 enclosure for long term
                                                                      remote measurements outdoor.
                                            Measurement uncertainty
                                            (volumetric flow rate): ±2 % of reading ±0.01 m/s
                                            Transmitter:
                                            Explosion protection:   –
                                            Power supply:           Power supply unit 100 ... 230 V AC / 50 ... 60 Hz, 12 V DC (socket at transmitter)
                                                                    integrated battery Li-Ion, up to 60 days operating time (minimum nightflow mode)
                                            Outputs:                4 - 20 mA passive, pulse / frequency / binary
                         4.99               Inputs:                 –
                                            Digital communication: –
                                            Available transducers:
                                     1.50
                                            Explosion protection:   –
            9.76
1.50
                                            Measurement uncertainty
                                            (volumetric flow rate): ±1 % of reading ±0.005 m/s
                                            Transmitter:
                                            Explosion protection:   –
                                            Power supply:           Power supply unit 100 ... 230 V AC / 50 ... 60 Hz, 12 V DC (socket at transmitter)
                                                                    integrated battery Li-Ion, > 25 h operating time
                                            Outputs:                4 - 20 mA active / passive, pulse / frequency / binary
      226                       59          Inputs:                 –
                                            Digital communication: Modbus RTU
                                            Available transducers:
                                            Explosion protection:   –
                   213
                                            Measurement uncertainty
                                            (volumetric flow rate): ±1 % of reading ±0.005 m/s
                                            Transmitter:
                                            Explosion protection:   –
                                            Power supply:           Power supply unit 100 ... 230 V AC / 50 ... 60 Hz, 12 V DC (socket at transmitter)
                                                                    integrated battery Li-Ion, > 25 h operating time
                                            Outputs:                4 - 20 mA active / passive, pulse / frequency / binary
      226                       59          Inputs:                 Pt100 / Pt1000, 4 - 20 mA passive
                                            Digital communication: Modbus RTU
                                            Available transducers:
                                            Explosion protection:   –
                   213
6
                                Portable Flow Meters FLUXUS® G601
                 FLUXUS® G601              The portable FLUXUS® G601 is the ideal metering solution for flexible operation
                 (Gases & Liquids)         during temporary control and service tasks on gas filled pipes. It also allows the
                                           measurememt at liquid filled pipes.
                 Measurement uncertainty
                 (volumetric flow rate):
                 Liquids                   ± 1% of reading ± 0.005 m/s
                 Gases                     ±1...3 % of reading ±0.005 m/s, depending on application
                 Transmitter:              Standard                                       Multifunctional
                 Explosion protection:     –
                 Power supply:             Power supply unit 100 ... 230 V AC / 50 ... 60 Hz, 12 V DC (socket at transmitter)
                                           integrated battery Li-Ion, > 25 h operating time
                 Outputs:                  4 - 20 mA active / passive, pulse / frequency / binary
                 Inputs:                   –                                              Pt100 / Pt1000, 4 - 20 mA passive
226         59
                 Digital communication:    Modbus RTU
                 Available transducers:
                 Explosion protection:     –
                 Pipe size range
      213
                 (inner diameter):
                 Liquids                   6 mm ... 6500 mm
                 Gases                     7 mm ... 1600 mm
                 Temperature range
                 (pipe wall):
                 Liquids                   -40 °C ... +200 °C / WI: -200 °C ... + 600 °C
                 Gases                     -40 °C ... +200 °C
                 FLUXUS® G601 CA           The portable FLUXUS® G601 CA Energy is the ideal metering solution for flexible
                 Energy                    operation during temporary control and service tasks. It allows the measurement
                 (Gases, Compressed Air,   of liquids, gases (incl. compressed air) and thermal energy quantities combined
                 Liquids & Thermal Energy) in one device.
                 Measurement uncertainty
                 (volumetric flow rate):
                 Liquids                   ± 1% of reading ± 0.005 m/s
                 Gases                     ±1...3 % of reading ±0.005 m/s, depending on application
                 Transmitter:
                 Explosion protection:     –
                 Power supply:             Power supply unit 100 ... 230 V AC / 50 ... 60 Hz, 12 V DC (socket at transmitter)
                                           integrated battery Li-Ion, > 25 h operating time
                 Outputs:                  4 - 20 mA active / passive, pulse / frequency /binary
                 Inputs:                   Pt100 / Pt1000, 4 - 20 mA passive
                 Digital communication: Modbus RTU
                 Available transducers:
226         59
                 Explosion protection:     –
                 Pipe size range
                 (inner diameter):
      213
                                                                                                                                7
Portable Flow Meter FLUXUS® F608
                        FLUXUS® F608              The portable FLUXUS® F608 is the ideal metering solution for flow measure-
                        (Liquids)                 ments on liquid filled pipes located in hazardous areas being ATEX (IECEx) Zone 2
                                                  and FM Class I, Div. 2 certified.
                        Measurement uncertainty
                        (volumetric flow rate): ±1 % of reading ±0.005 m/s
                        Transmitter:
                        Explosion protection:   ATEX/IECEx zone 2, FM Class I, Div. 2
                        Power supply:           Power supply unit 100 ... 230 V AC / 50 ... 60 Hz, only for use in non-ex areas
                                                12 V DC (socket at transmitter) integrated battery Li-Ion, > 25 h operating time
                        Outputs:                4 - 20 mA active / passive, pulse / frequency / binary
      226          59
                        Inputs:                 –
                        Digital communication: –
                        Available transducers:
                        Explosion protection:   ATEX/IECEx zone 1 / zone 2, FM Class I, Div. 2
                        Pipe size range
             213
                        Measurement uncertainty
                        (volumetric flow rate): ±1 % of reading ±0.005 m/s
                        Transmitter:
                        Explosion protection:   ATEX/IECEx zone 2, FM Class I, Div. 2
                        Power supply:           Power supply unit 100 ... 230 V AC / 50 ... 60 Hz, only for use in non-ex areas
                                                12 V DC (socket at transmitter) integrated battery Li-Ion, > 25 h operating time
                        Outputs:                4 - 20 mA active / passive, pulse / frequency / binary
                        Inputs:                 Pt100 / Pt1000
      226          59
                        Digital communication: –
                        Available transducers:
                        Explosion protection:     ATEX/IECEx zone 1 / zone 2, FM Class I, Div. 2
             213
 8
                               Portable Flow Meters FLUXUS® G608
                 FLUXUS® G608              The portable FLUXUS® G608 is the ideal metering solution for flow measure-
                 (Gases & Liquids)         ments on gas pipes located in hazardous areas being ATEX (IECEx) Zone 2 and FM
                                           Class I, Div. 2 certified. It also allows the measurememt at liquid filled pipes.
                 Measurement uncertainty
                 (volumetric flow rate):
                 Liquids                   ± 1% of reading ± 0.005 m/s
                 Gases                     ±1...3 % of reading ±0.005 m/s, depending on application
                 Transmitter:
                 Explosion protection:     ATEX/IECEx zone 2, FM Class I, Div. 2
                 Power supply:             Power supply unit 100 ... 230 V AC / 50 ... 60 Hz, only for use in non-ex areas
                                           12 V DC (socket at transmitter) integrated battery Li-Ion, > 25 h operating time
                 Outputs:                  4 - 20 mA active / passive, pulse / frequency / binary (only available for
                                           ATEX/IECEx Zone 2 approved version)
                 Inputs:                   –
                 Digital communication:    –
226         59
                 Available transducers:
                 Explosion protection:     ATEX/IECEx zone 1 / zone 2, FM Class I, Div. 2
                 Pipe size range
                 (inner diameter):
      213
                                                                                                                              9
Stationary Transmitters
                                                  FLUXUS® F50X              The FLUXUS® F50X is a basic meter available in dedicated solution packages
                                                  (Water & Thermal Energy) for water, thermal energy and flexible tubing applications. The basic meter
                                                                            FLUXUS® F501 is designed for water / glycol applications, in connection with IP68
                                                                            rated transducers allowing for measurements at buried water supply lines.
                                                  Measurement uncertainty
                                                  (volumetric flow rate): ± 1.5% of reading ± 0.01 m/s
                                                  Transmitter:            F501                           F502 TE – Thermal             F501 Semiconductor
                                                                                                         Energy (Water only)           (for liquids in tubes)
                                                  Explosion protection:   –
                                                  Power supply:           100 ... 230 V AC / 50 ... 60 Hz, 12 / 24 V DC
                                                  Outputs:                4 - 20 mA active, pulse / binary
                                                  Inputs:                 –                              Pt100 / Pt1000                –
                                                  Digital communication: Modbus RTU, BACnet , MS/TP, M-Bus
      165
                                                  Available transducers:
                        Ø 8.4
Ø 4.5
                                                  Explosion protection:   –
                 103
                 140
                                                  (pipe wall):            -40 °C ... +100 °C             -40 °C ... +100 °C            -20 °C ... +100 °C
                                                  FLUXUS F721 ®              The non-invasive FLUXUS F721 ultrasonic liquid flow meter is setting
                                                                                                       ®
           329                  106,2
                                        12,2      Pipe size range
                                                  (inner diameter):         6 mm ... 6500 mm                               25 mm ... 1000 mm
                                                  Temperature range
                                                  (pipe wall):              -40 °C ... +240 °C / WI: -200 °C ... +600 °C -40 °C ... +200 °C
                                                  FLUXUS® F706              The non-invasive 4-channel ultrasonic liquid flow meter FLUXUS® F706 offers
                                                  (Liquids)                 highest precision and is used for control and redundancy measurements of
                                                                            custody transfer meters or for usage in protective systems for leak detection.
                                                  Measurement uncertainty
                                                  (volumetric flow rate):   ± 1% of reading ± 0.005 m/s
                                                  Transmitter:
                                                  Explosion protection:     ATEX/IECEx zone 2, FM Class I /Div 2
                                                  Power supply:             100 ... 230 V AC / 50 ... 60 Hz, 12 / 24 V DC
                                                  Outputs:                  4-20 mA active /passive, 4-20 mA HART active/passive,
                                                                            pulse / frequency / binary
                                                  Inputs:                   Pt100 /Pt1000, 4-20 mA active /passive binary
     287
     265
                                 70
                                 10               Digital communication:    Modbus RTU, Foundation Fieldbus
                                                  Available transducers:
                                        Ø 4.5
                                  FLUXUS® F721WD            The FLUXUS® F721WD is the ideal flow metering solution for water suppliers.
                                  (Water)                   With their IP68 rated transducers the meters can easily be buried underground and
                                                            work on even the most difficult pipes.
                                  Measurement uncertainty
                                  (volumetric flow rate):   ± 1% of reading ± 0.005 m/s
                                  Transmitter:
                                  Explosion protection:     –
                                  Power supply:             100 ... 230 V AC / 50 ... 60 Hz, 12 / 24 V DC
                                  Outputs:                  4 - 20 mA active / passive, 4 - 20 mA HART active /passive, pulse / frequency / binary
                                  Inputs:                   –
                                  Digital communication:    Modbus RTU/TCP, BACnet MSTP/IP, M-Bus, Profibus PA, Foundation Fieldbus
                                  Available transducers:
                             B
                                  Explosion protection:     –
            261
                          12,2
                                  (inner diameter):         50 mm ... 6500 mm
                                  Temperature range
      329         106,2
                             B
                                  Digital communication:    Modbus RTU/TCP, BACnet MSTP/IP,         Modbus RTU, BACnet MS/TP, M-Bus
                                                            M-Bus, Profibus PA, Foundation Fieldbus
                                  Available transducers:
            261
      329         106,2
                          12,2    Pipe size range (inner
                                  diameter):                7 mm ... 1600 mm                            7 mm ... 250 mm
                                  Temperature range
                                  (pipe wall):              -40 °C ... +240 °C                         -40 °C ... +150 °C
                                  FLUXUS® G706              The non-invasive 4-Channel ultrasonic gas flow meter FLUXUS® G706 offers
                                  (Gases)                   highest precision and is used for control and redundancy measurements of
                                                            custody transfer meters or for usage in protective systems for leak detection.
                                  Measurement uncertainty
                                  (volumetric flow rate):   ±1...3 % of reading ±0.005 m/s, depending on application
                                  Transmitter:
                                  Explosion protection:     ATEX/IECEx zone 2, FM Class I, Div. 2
                                  Power supply:             100 ... 230 V AC / 50 ... 60 Hz, 12 / 24 V DC
                                  Outputs:                  4 - 20 mA active / passive, 4 - 20 mA HART active / passive,
                                                            pulse / frequency / binary
                                  Inputs:                   Pt100 / Pt1000, 4 - 20 mA active / passive, binary
287
265
                   70
                   10             Digital communication:    Modbus RTU, Foundation Fieldbus
                                  Available transducers:
                          Ø 4.5
                                                                                                                                               11
Stationary Transmitters
Liquids (F)
ATEX (IECEx) Zone 1, FM Class I, Div. 1 certified
                                                                FLUXUS® F809                 The FLUXUS® F809 is an ATEX (IECEx) zone1 and FM Class I, div. 1 approved dual
                                                                (Liquids)                    channel liquid flow meter for any industrial environment. It can even be employed
                                                                                             at extreme temperatures ranging from -190 °C up to +600 °C.
                                                                Measurement uncertainty
                                                                (volumetric flow rate):      ± 1% of reading ± 0.005 m/s
                                                                Transmitter:
                                                                Explosion protection:        ATEX/IECEx zone 1, FM Class I /Div 1
                                                                Power supply:                100 ... 230 V AC / 50 ... 60 Hz, 24 V DC
                                                                Outputs:                     4-20 mA active /passive, 4-20 mA HART active / passive,
                                                                                             4 - 20 mA HART passive intrinsic safety, pulse / frequency / binary
                                                                Inputs:                      –
                136
                      243                   285,5
                                              70                Digital communication:       Modbus RTU
                                                                Available transducers:
                                                    9
                                                                Measurement uncertainty
                                                                (volumetric flow rate):      ± 1% of reading ± 0.005 m/s
                                                                Transmitter:
                                                                Explosion protection:        ATEX/IECEx zone 1
                                                                Power supply:                100 ... 230 V AC / 50 ... 60 Hz, 24 V DC
                                                                Outputs:                     4-20 mA active /passive, 4-20 mA HART active / passive,
                                                                                             4 - 20 mA passive intrinsic safety, pulse / frequency / binary
                                                                Inputs:                      –
                                                                Digital communication:       Modbus RTU
                                                                Available transducers:
                189                       195
                                                                                                         Gases (G)
                                                                  ATEX (IECEx) Zone 1, FM Class I, Div. 1 certified
                                                  FLUXUS® G809              The FLUXUS® G809 is an ATEX (IECEx) zone1 and FM Class I, div. 1 approved dual
                                                  (Gases)                   channel gas flow meter for any industrial environment. It accurately and reliably
                                                                            measures any gaseous medium.
                                                  Measurement uncertainty
                                                  (volumetric flow rate):   ±1...3 % of reading ±0.005 m/s, depending on application
                                                  Transmitter:
                                                  Explosion protection:     ATEX/IECEx zone 1, FM Class I /Div 1
                                                  Power supply:             100 ... 230 V AC / 50 ... 60 Hz, 24 V DC
                                                  Outputs:                  4 - 20 mA active / passive, 4 - 20 mA HART active / passive,
                                                                            4 - 20 mA HART passive intrinsic safety, pulse / frequency / binary
                                                  Inputs:                   –
                136
                      243     285,5
                                70                Digital communication:    Modbus RTU
                                                  Available transducers:
                                      9
                                                  Measurement uncertainty
                                                  (volumetric flow rate):   ±1...3 % of reading ±0.005 m/s, depending on application
                                                  Transmitter:
                                                  Explosion protection:     ATEX/IECEx zone 1
                                                  Power supply:             100 ... 230 V AC / 50 ... 60 Hz, 24 V DC
                                                  Outputs:                  4 - 20 mA active / passive, 4 - 20 mA HART active / passive,
                                                                            4 - 20 mA passive intrinsic safety, pulse / frequency / binary
                                                  Inputs:                   –
                                                  Digital communication:    Modbus RTU
                                                  Available transducers:
                189         195
                                                                                                                                                           13
Clamp-On Ultrasonic Transducers
FLEXIM has developed two transducer technologies in order            Shear wave Transducers
to ensure the highest possible measuring accuracy even in
                                                                     Typ
challenging environments: shear wave transducers with a fo-
cused signal insertion for measuring liquids and Lamb wave           FSG
transducers with a wide signal insertion into the medium for         FSK
measuring the flow of gases.                                         FSM
                                                                     FSP
In order to guarantee measurements with long-term stability
                                                                     FSQ
in harsh industrial environments, the transducers and cable
                                                                     FSS
connections are made of stainless steel and are available in
explosion-proof designs.                                                               5           10        50         100          500     1000    5000
                                                                     Inner pipe diameter in mm
                                                                     (no limitations by pipe wall thickness or pipe wall material)
Techn. drawing:
Operating temp.:         -30 °C ... +130 °C    -40 °C ... +130 °C     -40 °C ... +130 °C           -40 °C ... +130 °C                 -40 °C ... +130 °C
(ext. temp. area):                            (-30 °C ... +200 °C)   (-30 °C ... +200 °C)
Protection degree: IP65 IP65, IP67 optional IP65, IP68 optional IP65, IP68 optional IP65, IP68 optional
Hazardous area           FM Class I, Div. 2   ATEX (IECEx)           ATEX (IECEx)                  ATEX (IECEx)                       ATEX (IECEx)
approval:                                     Zone 1 and 2           Zone 1 and 2                  Zone 1 and 2                       Zone 1 and 2
                                              FM Class I,            FM Class I,                   FM Class I, Div. 1/ 2              FM Class I, Div. 1 / 2
                                              Div. 1 / 2             Div. 1 / 2
 14
                                                      Clamp-On Ultrasonic Transducers
Lamb wave transd.             GLQ                     GLP / GLM             GLH / GLK                     GLG                             GLF
Shear wave transd.*           -                       GSP / GSM             GSK                           GSG                             -
for gases:
Techn. drawing:
Dimensions of standard 42 x 22 x 25.5                 74 x 32 x 40.5        128.5 x 51 x 67.5             128.5 x 51 x 67.5               163 x 54 x 91.3
transducers
in mm (l x w x h):
Operating temp.: -40 °C ... +170 °C -40 °C ... +170 °C -40 °C ... +170 °C -40 °C ... +170 °C -40 °C ... +170 °C
Protection degree: IP65, IP68 optional IP65, IP68 optional IP65, IP68 optional IP65, IP68 optional IP65
Hazardous area                ATEX (IECEx)           ATEX (IECEx)           ATEX (IECEx)           ATEX (IECEx)           ATEX (IECEx)
approval:                     Zone 1 and 2           Zone 1 and 2           Zone 1 and 2           Zone 1 and 2           Zone 1 and 2
                              FM Class I, Div. 1 / 2 FM Class I, Div. 1 / 2 FM Class I, Div. 1 / 2 FM Class I, Div. 1 / 2 FM Class I, Div. 1 / 2
Whether for quick installations during temporary                   When the going gets tough
measurement or for permanent installations,
whether for large pipes or small tubes: FLEXIM                     FLEXIM invented the WaveInjector® for extreme tem-
offers the right transducer mounting fixture for                   peratures. The patented device separates the ultra-
every application.                                                 sonic transducers thermally from the pipe thereby
                                                                   extending the application range of non-intrusive
VARIOFIX transducer systems offer the best stability:              clamp-on ultrasonic technology to temperatures
the sturdy mounting devices permanently ensure                     from -190 °C to 600 °C.
the ultrasonic transducers are positioned precisely.
Sophisticated, constructive details guarantee constant-            The WaveInjector® is a transducer mounting device and
ly high contact pressure even with high fluctuations in            so much heat is radiated or absorbed via its metallic
temperature thereby ensuring long-term stable high                 coupling plates that the temperature of the transducer
signal quality.                                                    clamping fixture lies within the working range of the
                                                                   ultrasonic transducers.
VARIOFIX L is the standard transducer mounting fixture
for permanent installation. VARIOFIX C provides opti-              The WaveInjector® is also mounted on the out-
mum protection even under the harshest conditions:                 side of the pipe without having to open the pipeline.
below the stainless steel cover, the measuring point is            Since it is a purely mechanical arrangement, the
permanently protected from external influences, from               WaveInjector® can also be used in hazardous areas.
wind and weather as well as from mechanical damage.
For temporary
measurements
Techn. drawing:
Material:              Stainless Steel: 304 (1.4301), 301   Stainless Steel: 304 (1.4301), 301   Steel, powder coated and textile
                       (1.4310), 303 (1.4305)               (1.4310), 303 (1.4305)               tension belt
Dimensions             414 x 94 x 76 (40)                   210 x 32 x 44 for S transducers      -
in mm (l x b x h):                                          420 x 48 x 58 for Q
                                                            and M transducers
 16
                                                      Transducer Mounting Fixtures
For permanent
measurements
Material
Standard:            Stainless Steel: 304 (1.4301),     Stainless Steel: 304 (1.4301),        Polypropylene (PP)
                     301 (1.4310)                       301 (1.4310)
Option Offshore:     Stainless Steel: 316 (1.4571),     Stainless Steel: 316 (1.4571)
                     316L (1.4404), 17-7PH (1.4568)
Dimensions           VLK: 423 x 90 x 93                 VCK-Large: 560 x 122 x 102           For outer pipe diameters:
in mm (l x b x h):   VLK opt. IP68: 443 x 94 x 105      VCK-Large opt. IP68: 560 x 126 x 102 3/8“, 1/2“, 3/4“, 1“, 1 1/4“
                     VLM: 309 x 57 x 63                 VCK-Small: 410 x 122 x 102           (others on request)
                     VLQ: 247 x 43 x 47                 VCK-Small opt. IP68: 410 x 126 x 102
                                                        VCM: 460 x 96 x 80
                                                        VCQ: 310 x 85 x 62
Description:         The PermaFix fixture is designed   The WaveInjector® is FLEXIM‘s         The WaveInjector® Cryo (FLUXUS
                     for mounting of FM Class I, Div.   mounting fixture for extreme pipe     Cryo) is FLEXIM‘s mounting fix-
                     1 transducers and associated       wall temperatures for as low as       ture for pipe temperatures below
                     conduits.                          -190 °C up to +600 °C.
                                                                                              -40 °C down to -190 °C
Techn. Drawing:
Material:            Stainless Steel: 304 (1.4301),     Stainless Steel: 304 (1.4301)         Stainless Steel: 304 (1.4301)
                     316 (1.4571) optional
Pipe size:           -                                  40 mm ... 1000 mm                     70 mm ... 1000 mm
Dimensions           PFK: 410 x 90 x 73                 WI-400K: l = 279 mm, h = 178 mm       l = 2 x l + lcp (l = 273 mm)
in mm (l x w x h):   PFM: 310 x 68 x 44                 WI-400M, WI-400Q, WI-4001, WI-        w = outer pipe diameter + 32 mm
                                                        4004: l = 243 mm, h = 170 mm          h = outer pipe diameter + 570 mm
                                                                                                                              17
18
                                                                      PIOX                                      ®
              Process Analytics by means of Ultrasound and Refractometry
Product characteristics like concentration and density can be monitored continuously online using PIOX® process
analysers: non-intrusively with PIOX® S clamp-on ultrasonic systems and wetted with the PIOX® R process
refractometer.
PIOX® brings analytics into the process Process insight through transmitted light
Both the acoustic measuring method and optical trans-     Refractometry – measurement of the refraction of
mitted light measurement basically involve velocities:    light – is a long-established method for determining
PIOX® S ultrasonic systems measure the propagation        the concentration, density or purity of liquid media.
velocity of sound in the medium – also non-intrusively    Refraction results from the change in the propagation
and with the same clamp-on ultrasonic transducers as      velocity of light as it passes from the medium to the
FLEXIM’s FLUXUS® flowmeter.                               measuring prism.
Due to the fact that density and volume flow are          Unlike conventionally used lab instruments, the
measured simultaneously, PIOX® S ultrasonic systems       PIOX® R process refractometer does not determine the
are particularly suitable for non-intrusively measuring   refractive index indirectly via the critical angle of the total
mass flow rates – especially where any leakage risk       reflection but directly measures the angle of refraction of
must absolutely be excluded.                              two monochromatic beams of light as they pass
                                                          through the sample stream. The patented differen-
                                                          tial measurement in the transmitted light method is
                                                          resistant to the formation of deposits and therefore
                                                          particularly reliable.
                                                                                                                   19
PIOX® S
PIOX® S transfers the practical advantages of clamp-     Non-intrusive online analytics with PIOX® S is the
on ultrasonic technology to process analytical appli-    method of choice when materials and processes
cations: since the transducers are simply mounted        demand the highest levels of safety and reliability, e.g. in
on the – safe – outside of the pipeline, they are not    the case of corrosive media like acids or alkalis or even
subject to any wear and tear by the medium flowing       toxic compounds.
inside. As there is no need to open the pipe for in-
stallation, mounting and initial operation can usually
be done during ongoing operation. Non-intrusive
process analytics with PIOX® S proves to be just as
versatile and flexible as non-intrusive flow measure-
ment with FLUXUS®:
 20
                                                                                                      PIOX® S and PIOX® ID
                                             PIOX® S721 /             PIOX® S can be used to determine the mass flow rate, density and concentration
                                             PIOX® S721 SA            of many chemical media in real-time by determination of the acoustic velocity
                                                                      and internal offsetting of the medium temperature.
                                                                      The product variant PIOX® S721 - SA is a derivative of PIOX® S and engineered
                                                                      for concentration, density and mass flow measurmement of Sulphuric Acid at
                                                                      80 to 100% conc.
                                             Measurement uncertainty
                                             (volumetric flow rate): ± 1% of reading ± 0.005 m/s
                                             Transmitter:             PIOX® S721                                      PIOX® S721 SA
                                             Explosion protection:    ATEX/IECEx Zone 2, FM Class I /Div 2            –
                                             Power supply:            100 ... 230 V AC / 50 ... 60 Hz, 12 / 24 V DC
                                             Outputs:                 4 - 20 mA active / passive, pulse / frequency / binary
Digital communication: Modbus RTU/TCP, BACnet MSTP/IP, Profibus PA, Foundation Fieldbus
                                             Available transducers:
       287               70                  Explosion protection:    ATEX/IECEx Zone 1 /                             –
                                                                      Zone 2 FM Class I / Div2
       265               10
                                     Ø 4.5
ø8.4
                                             Power supply:            100 ... 230 V AC / 50 ... 60 Hz, 24 V DC
                                             Outputs:                 4 - 20 mA active (status), binary (status)
                               71
83
ø4.5
             205
                                             Digital communication:   –
                                             Available transducers:
                                             Explosion protection:    –
                               140
                         103
                                                                                                                                                        21
PIOX® R
Using PIOX® R, the well-tried transmitted light measurement as a laboratory practice is reliable in
the process. Measurement via the patented transmitted light method ensures maximum reliability.
Extremely high measuring accuracy is achieved by measuring the refraction of two monochromatic light beams
and evaluating the difference.
The PIOX® R comes in two versions, tailored to the requirements of various industries: the PIOX® R500-H for
applications where hygiene is particularly important, e.g. in the pharmaceutical, food and drinks industries as
well as the PIOX® R500-C for applications in the chemical industry. Both versions are available in various designs,
materials and with a variety of flange styles which cover a wide range of applications.
Process refractometer for hygienic applications Process refractometer for chemical applications
PIOX® R500-H was developed especially for appli-            PIOX® R500-C was developed especially for applica-
cations which require the highest level of purity and       tions in the chemical industry. The sophisticated design
hygiene. The sensor unit is characterised by its cavity-    and high-quality materials ensure operational safety
free design which effectively prevents impurities from      even ander challenging conditions, e.g. when mea-
accumulating.                                               suring highly aggressive media as well as in potentially
                                                            explosive areas.
 22
                                                                                                PIOX® R
      PIOX® R721/R500           The hygienic design of the PIOX® R721/R500 is the ideal process refractometer
      Hygienic design           for applications in the pharmaceutical and food & beverages industry.
                                The PIOX® R721/R500 offers maximum process reliability, the highest level of
                                precision and is resistant to deposit formation.
      Measurement uncertainty
      (volumetric flow rate): nD: 0.0002 (corresponds to 0.1 °Brix, typical 0.1 wt%)
      Transmitter (R721):
Digital communication: Modbus RTU/TCP, BACnet MSTP/IP, Profibus PA, Foundation Fieldbus
Sensor (R500):
Pressure range: PN 10
      PIOX® R721/R500           The chemical design of the PIOX® R721/R500 is the ideal process refractometer
      Chemical design           for applications in the chemical industry. Due to the special seal design and the
                                fact that the measuring head is separated from the transducer equipment, the
                                PIOX® R721/R500 ensures maximum process reliability even in the presence of
                                corrosive and toxic media.
      Measurement range:        nD: 1.3 ... 1.7, °Brix: 0 ...100
      Measurement uncertainty
      (volumetric flow rate): nD: 0.0002 (corresponds to 0.1 °Brix, typical 0.1 wt%)
      Transmitter (R721):
Digital communication: Modbus RTU/TCP, BACnet MSTP/IP, Profibus PA, Foundation Fieldbus
Sensor:
Process connection: DIN/ANSI flange, proprietary FLEXIM flow cell, standard sight glass fitting
                                                                                                              23
In partnership
For almost three decades, FLEXIM has been leading the way nationally         FLEXIM GmbH
and internationally for process instrumentation in many areas of             Berlin, Germany
                                                                             Phone: +49 30 93 66 76 60
industry. As a technology leader and pioneer in the field of non-intrusive   info@flexim.de
clamp-on ultrasonic flow measurement of liquids and gases, FLEXIM
                                                                             FLEXIM Austria GmbH
has repeatedly set standards. In addition to non-intrusive flow measure-     Olbendorf, Austria
ment, innovative process analytical methods using ultrasound or              Phone: +43 33 26 529 81
refractometry are another focal point of our program.                        office@flexim.at
                                                                             FLEXIM Instruments Benelux B.V.
Permanently forward-looking                                                  Berkel en Rodenrijs, Netherlands
                                                                             Phone: +31 10 24 92 333
We’re not resting on our laurels. Every year, we invest generously in        benelux@flexim.com
research and development to further strengthen our position as a tech-       FLEXIM France SAS
nological leader.                                                            Limonest, France
In addition to that, we maintain close contact with our customers.           Tél. : +33 4 27 46 52 10
Innovative and reliable products that meet the requirements of end           info@flexim.fr
users are the result.                                                        FLEXIM Instruments UK Ltd.
                                                                             Northwich, UK
                                                                             Phone: +44 1606 781 420
FLEXIM Measurement Services provides you with answers
                                                                             sales@flexim.co.uk
In today’s energy efficient and environmentally conscious environment,       FLEXIM Middle East
facility and plant metering must be verified and calibrated for accuracy     Dubai, U.A.E.
                                                                             Phone: +971 4430 5114
to meet audit and regulatory demands. This is especially true for energy     salesme@flexim.com
intensive industries such as Power Generation, Oil & Gas, Chemical and
                                                                             FLEXIM Instruments
Processing industries.                                                       Asia Pte Ltd.
We confirm and verify flow rates of existing volume and mass flow            Singapore, Singapore
meters at your industry-specific application.                                Phone: +65 67 94 53 25
                                                                             salessg@flexim.com
We also offer complete thermal energy measurements that can help             FLEXIM Instruments China
you to evaluate the performance of your plant and processes.                 Shanghai, China
We provide formal reports and in-depth data by employing our trace-          Phone: +86 21 64 95 75 20
                                                                             shanghai@flexim.com
able calibrated portable meters along with sophisticated diagnostic
software.                                                                    FLEXIM S.A
                                                                             Santiago de Chile, Chile
Our products are hazardous area approved (ATEX (IECEx) Zone 2 (1)            Phone: +56 22 32 03 62 80
and FM Class I, Div. 2) and provide measurements in even the most            info@flexim.cl
                                                                                                                 11/2019 Subject to change without notification
demanding environments, e.g. Offshore Platforms, or Refineries at pipe       FLEXIM AMERICAS Corporation
temperatures up to +600 °C and beyond.                                       New York, USA
                                                                             Phone: +1 63 14 92 23 00
                                                                             salesus@flexim.com
                                                                             FLEXIM Service and
                                                                             Support Center South America
                                                                             Esco Argentina S.A., Buenos Aires
                                                                             Phone: +54 11 49 20 71 00
                                                                             flexim@escoarg.com.ar
                                                                             www.escoarg.com.ar
                                                                             www.flexim.com
                                                                                                                 BUPRODUCTV3-1EN