ENERGIN® CHP
Combined Heat and Power units
                        ENERGIN® CHP units produce heat and electrical power at the same time. The heat recovery is from engine jacket water,
                        exhaust, lube oil and the first stage of mixture cooling.
                        The gas engines of the M-Series of R Schmitt Enertec are the base of the ENERGIN® CHP units in the range of 100 - 500 kW
                        electrical power. The engines are specially designed and manufactured by us for the operation with the following fuels:
                        Natural gas, biogas, LPG, woodgas and special gases. As an option they can be equipped with an absorption chiller for
                        cooling. With the additionally sound enclosure, that is mounted the common frame, the sound level can be reduced to less
                        than 70 dB(A). CHP are easy to install and save on space because all major components are mounted on the common frame
                        and are ready piped and cabled.
              ENERGIN® type    Engine type      Electrical    Electrical    Thermal      Overall       Engine specification
                                                 power       efficiency      power      efficiency
              M06 CHP G100     M06-GN0W22        100 kW        34,6 %       166 kW       92,0 %        Bore               [mm]       128 [in line engines]        130 [V-engines]
natural gas
              M06 CHP G122     M06-GN0W22        122 kW        35,1 %       198 kW       92,0 %        Stroke             [mm]       155 [in line engines]        142 [V-engines]
              M08 CHP G151     M08-GN0W22        151 kW        36,0 %       235 kW       92,1 %
                                                                                                       Speed          [U/min]        1.500
              M06 CHP G173     M06-GTIW22        173 kW        35,8 %       264 kW       90,5 %
              M06 CHP G185     M06-GT2W22        185 kW        36,5 %       260 kW       87,8 %        Mean piston        [m/s]      7,75 [in line engines]
                                                                                                       speed                         7,1 [V-engine]
              M06 CHP G205     M06-GT2D22        205 kW        37,5 %       266 kW       86,1 %
              M08 CHP G220     M08-GTIW22        220 kW        37,3 %       314 kW       90,5 %
                                                                                                       Applicable gas types          G  =  natural gas
              M08 CHP G233     M08-GT2W22        233 kW        37,7 %       309 kW       87,7 %
                                                                                                                                     B  =  biogas
              M08 CHP G260     M08-GT2D22        260 kW        37,8 %       332 kW       86,0 %                                      H  =  woodgas and other low calorific gases
              M12 CHP G334     M12-GTIW22        334 kW        36,6 %       496 kW       90,9 %                                      P  =  propane and other high calorific gases
              M12 CHP G350     M12-GT2W22        350 kW        38,1 %       458 kW       87,9 %
                                                                                                       Aspiration                    N  =  natural
              M12 CHP G400     M12-GT2D22        400 kW        38,5 %       498 kW       86,4 %                                       T  =  turbocharged
              M12 CHP G500     M12-GM2D21        500 kW        39,5 %       587 kW       85,8 %                                      M  =   turbocharged with Miller Cycle
              M06 CHP B115     M06-BT0W21        115 kW        37,0 %       153 kW       86,2 %
biogas
                                                                                                       Mixture cooling	               0  = none
              M06 CHP B173     M06-BTIW22        173 kW        37,2 %       227 kW       86,0 %                                        I  = internal
              M06 CHP B205	    M06-BT2D22        205 kW        38,8 %       227 kW       81,8 %                                       2  = double stage internal / external
              M08 CHP B233     M08-BT2W22        233 kW        38,1 %       278 kW       83,5 %        Exhaust manifolds              W =  watercooled
              M08 CHP B260     M08-BT2D22        260 kW        41,6 %       251 kW       81,8 %                                       D   =  dry, insulated
              M12 CHP B350     M12-BT2W22        350 kW        38,9 %       405 kW       83,9 %
              M12 CHP B400     M12-BT2D22        400 kW        40,2 %       418 kW       82,2 %        ENERGIN® type                       M06                M08             M12
              M12 CHP B500     M12-BM2D21        500 kW        41,2 %       493 kW       81,7 %        No. of cylinders /              6 in line          8 in V90°        12 in V90°
              M08 CHP H166     M08-HT2D22        166 kW        33,1 %       255 kW       84,0 %        configuration
woodgas
              M12 CHP H250     M12-HT2D22        250 kW        33,5 %       376 kW       83,9 %        capacity             [ltr.]        12,0                 15,1            22,6
CHP Basic scope of supply
Four stroke gas engine coupled with double bearing alternator, mounted on common frame                                                                     ●
Sound attenuating enclosure with air ventilation mounted on common frame with engine and generator                                                         ○
Heat recovery from engine jacket water, exhaust, lube oil and 1 stage intercooler. st
                                                                                                                                                           ●
Cooling the exhaust temperature to 120°C with natural gas and 180°C with biogas applications
Remote radiator for 2nd stage mixture cooling                                                                                                              ○
Remote radiator for jacket water, lubrication oil, 1 stage intercooler and exhaust heat
                                                                 st                                                                                        ○
ENERSCREEN® control system with touchpanel for engine, generator and auxiliaries set mounted in switchboard.                                               ●
With synchronizing and generator protection functions
Generator circuit breaker set mounted in switchboard                                                                                                       ●
Electric pre-lubrication pump with change over valve to use the pump for oil drainage and oil change                                                       ●
Set mounted lube oil make up tank with automatic level control on the engine oil pan                                                                       ●
for automatic compensation of the oil consumption
Exhaust primary silencer set mounted in common frame                                                                                                       ●
Exhaust secondary silencer for higher noise protection in loose supply                                                                                     ○
○ as an option         ● included
                                                                                                                                                               FLY_CHP_Trios_052015_V_03_EN
  © R Schmitt Enertec GmbH 05/2015
  ENERGIN® and         are registered trademarks of and licensed by            GmbH. The use of other brands or trademarks contained in this document by
  a third party may result in a violation of the rights of the holders of the license plate. Subject to errors and technical modifications excepted.
                                                                                                                          Represented in Tunisia by
                                          R Schmitt Enertec GmbH                                                          Trios Energy
                                          Siemensstraße 13                                                                5080 Téboulba - Monastir
                                          56743 Mendig - Germany                                                          trios.energy.suarl@gmail.com
                                          www.rschmitt-enertec.com                                                        contact@trios-energy.com
                                          info@rschmitt-enertec.com