Customer Care Bulletin: Models ALL Date 12.08.16 Subject

The document discusses fuel tank capacity and combination units used to measure fuel levels. It notes that combination units can only measure fuel within the effective tank capacity, not accounting for upper and lower dead stock. To select the proper combination unit, the effective tank height must be measured and referenced against part number tables listing specifications for various generator models. Technical details are provided on testing combination units and measuring resistance values at different fuel levels.

Uploaded by

Hitesh Shinde
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
97 views4 pages

Customer Care Bulletin: Models ALL Date 12.08.16 Subject

The document discusses fuel tank capacity and combination units used to measure fuel levels. It notes that combination units can only measure fuel within the effective tank capacity, not accounting for upper and lower dead stock. To select the proper combination unit, the effective tank height must be measured and referenced against part number tables listing specifications for various generator models. Technical details are provided on testing combination units and measuring resistance values at different fuel levels.

Uploaded by

Hitesh Shinde
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

CUSTOMER CARE BULLETIN

Group Genset Bulletin No. MP/CC/16-17/010 Pages 1 of 4


Models ALL Date 12.08.16

Subject Fuel Tank Capacity and Combination Unit

Combination Unit can only measure fuel level within the EFFECTIVE TANK CAPACITY. It can’t measure Upper Dead Stock and Lower Dead Stock, although this
stock of fuel is usable. To choose a suitable Combination Unit for a Fuel Tank, EFFECTIVE TANK HEIGHT should be measured and then part number can be
identified (refer tables).

Technical Communication | Mahindra Powerol


Introduction of Sensor Common Point Page 2 of 4

To test the Combination Unit, check the resistance values at various levels.

Bulletin No. MP/CC/16-17/007


Introduction of Sensor Common Point Page 3 of 4

RETAIL
Tank outer Tank inner dimension Dead Dead
FT Total dead
dimesion(mm) (mm) stock(15 stock(10
Effective capacity stock (lits) Effective FT
+/-2mm) +/-2mm) Combintion
SR No Retail Thickness tank (including consider capacity for
from FT from FT Unit part no
height(ETH) dead during CU CU calibration
L W H L W H bottom top
stock) calibration
surface surface
1 7.5 to 12.5 kVA leaf 998 798 110 1.2 113.8 996.56 795.6 107.6 85 17 12 23.0 62.3 006028255H91
2 15 to 20 kVA leaf 1104 798 121 1.2 124.8 1102.56 795.6 118.6 104 17 12 25.4 78.6 006027978H91
3 25 kVA leaf 1104 798 121 1.2 124.8 1102.56 795.6 118.6 104 17 12 25.4 78.6 006027978H91
4 18.5kVA SD for MCP/AMF 1450 674 102 2 105 1447.6 670 98 95 17 12 28.1 66.9 006022177H91
5 25kVA SD DG for MCP 1450 674 102 2 105 1447.6 670 98 95 17 12 28.1 66.9 006022177H91
6 25(AMF)-30-40(MCP/AMF) kVA SI 1220 801 140 2 143 1217.6 797 136 132 17 12 28.1 103.8 006021583H91
7 50-62.5 kVA Compact SO (MCP/AMF) 1282 974 126 2 129 1279.6 970 122 151 17 12 36.0 115.4 006023608H91
8 50-62.5 kVA Compact SI (MCP/AMF) 1045 970 156 2 159 1042.6 966 152 153 17 12 29.2 123.9 006021917H91
9 75 kVA SO (MCP/AMF) DG 1920 830 121 2 124 1917.6 826 117 185 17 12 45.9 139.4 006027978H91
10 82.5-100 kVA MHEPL SO(MCP/AMF) 1350 954 166 2 169 1347.6 950 162 207 17 12 37.1 170.3 006024428H91
11 82.5kVA MHEPL SI(MCP/AMF) 1350 954 130 2 133 1347.6 950 126 161 17 12 37.1 124.2 006021822H91
12 100 kVA MHEPL SI(MCP/AMF) 1350 954 166 2 169 1347.6 950 162 207 17 12 37.1 170.3 006024428H91
13 125kVA MHEPL SO MCP DG 1285 985 200 2 203 1282.6 981 196 247 17 12 36.5 210.1 006021253H91
125(AMF) -160(MCP/AMF) kVA MHEPL SI
14 1575 920 170 2 173 1572.6 916 166
DG 239 17 12 41.8 197.3 006022180H91
15 125 kVA DG – COE 1825 754 170 2 173 1822.6 750 166 227 17 12 39.6 187.3 006022180H91
16 180-200 kVA MHEPL SO MCP DG 2080 981 202 2 205 2077.6 977 198 402 17 12 58.9 343.0 006021253H91
17 180-200 kVA MHEPL SI AMF DG 1800 1154 200 2 203 1797.6 1150 196 405 17 12 59.9 345.2 006021253H91
18 250-300kVA MHEPL SO MCP/AMF DG 2014 1249 233 2 236 2011.6 1245 229 574 17 12 72.6 500.9 006029100H91

Bulletin No. MP/CC/16-17/007


Introduction of Sensor Common Point Page 4 of 4

TELECOM
Dead
stock(10
Dead
Tank inner dimension FT +/-2mm) Total dead
Tank outer dimesion(mm) stock(15
Effective (mm) capacity from FT stock (lits) Effective FT
+/-2mm) Combintion
SR No Retail Thickness tank (including top consider capacity for
from FT unit part no
height(ETH) dead surface during CU CU calibration
bottom
stock) calibration
surface
L W H L W H

1 7.5-15 kVA SD ECP 1460 678 260 2 263 1456 674 256 251 17 12 28.5 222.8 006022178H91
2 7.5-15 kVA SD AMF(RIL) 1460 678 260 2 263 1456 674 256 251 17 12 28.5 222.8 006027959H91
3 20 kVA Compact ECP DG 1600 684 237 2 240 1596 680 233 253 17 12 31.5 221.4 006022179H91
4 25 kVA Compact ECP DG 1324 750 260 2 263 1320 746 256 252 17 12 28.6 223.5 006022178H91
5 30-40 KVA SI ECP DG 1232 804 260 2 263 1228 800 256 251 17 12 28.5 223.0 006022178H91
6 25-30-40 KVA SI AMF DG 1572 801 210 2 213 1568 797 206 257 17 12 36.2 221.2 006021585H91
7 50-62.5 KVA SI Compact with 250lts FT 1045 970 254 2 257 1041 966 250 251 17 12 29.2 222.2 006025679H91
8 75kva SO ECP with 250lts FT (retail canopy) 1920 830 121 2 124 1916 826 117 185 17 12 45.9 139.3 006027978H91
9 82.5-100kva SI DG with 250lts FT 1350 954 200 2 203 1346 950 196 251 17 12 37.1 213.5 006021253H91
82.5-100kva SO SP DG with 250lts FT for
10 1350 954 200 2 203 1346 950 196
Reliance 251 17 12 37.1 213.5 006021253H91
11 125kva DG for Telecom Reliance 1285 985 200 2 203 1281 981 196 246 17 12 36.4 209.9 006021253H91
12 15 kVA SS Single Door 1460 782 236 2 239 1456 778 232 263 17 12 32.9 230.0 006022179H91
13 15 kVA USS Double Door 1500 1200 150 2 153 1496 1196 146 261 17 12 51.9 209.3 006021917H91
14 25 kVA SS Double Door 1700 850 160 2 163 1696 846 156 224 17 12 41.6 182.2 006021584H91
15 25 kVA USS Double Door 1336 1250 151 2 154 1332 1246 147 244 17 12 48.1 195.8 006021917H91

Bulletin No. MP/CC/16-17/007