0% found this document useful (0 votes)
125 views4 pages

RM35JA32MR: Product Datasheet

This document provides product specifications for a current control relay called the RM35JA32MR. It is a modular measurement and control relay that can detect overcurrent or undercurrent conditions between 0.15A and 15A. It has adjustable time delays between 0.1 and 30 seconds and can switch voltages up to 250V AC with a maximum switching current of 8A AC. Environmental specifications include operating temperatures between -20°C and 50°C.

Uploaded by

maherianto 29
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
125 views4 pages

RM35JA32MR: Product Datasheet

This document provides product specifications for a current control relay called the RM35JA32MR. It is a modular measurement and control relay that can detect overcurrent or undercurrent conditions between 0.15A and 15A. It has adjustable time delays between 0.1 and 30 seconds and can switch voltages up to 250V AC with a maximum switching current of 8A AC. Environmental specifications include operating temperatures between -20°C and 50°C.

Uploaded by

maherianto 29
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Product datasheet RM35JA32MR

Characteristics Current control relay 0.15A…15A, 2 C/O

Main
Range of product Zelio Control
Product or component type Modular measurement and control relays
Relay type Current control relay
Relay name RM35JA
Relay monitored parameters Overcurrent or undercurrent detection
Overcurrent or undercurrent in window mode
Time delay type Adjustable 0.1...30 s, +/- 10 % of the full scale
value on crossing the threshold Tt
Switching capacity in VA 2000 VA
Measurement range 0.15...1.5 A E1-M terminals
0.5...5 A E2-M terminals
1.5...15 A E3-M terminals

It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
150 mA...15 A current AC/DC 50/60 Hz

Complementary
Reset time <= 1500 ms at maximum voltage
Maximum switching voltage 250 V AC
Minimum switching current 10 mA at 5 V DC
Maximum switching current 8 A AC

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
[Us] rated supply voltage 24...240 V AC/DC, 50/60 Hz (+/- 10 %)

Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Supply voltage limits 20.4...264 V AC/DC
Control circuit voltage limits - 15 % + 10 % Un
Power consumption in VA 3.5 VA AC
Power consumption in W 1.5 W DC
Resistance across terminals 0.005 Ohm at E3-M terminals
0.015 Ohm at E2-M terminals
0.05 Ohm at E1-M terminals
Output contacts 2 C/O
Nominal output current 8A
Internal input resistance 0.05 Ohm
0.015 Ohm
0.005 Ohm
Setting accuracy of the switching threshold +/- 10 % of the full scale
Switching threshold drift <= 0.05 % per degree centigrade depending permissible ambient air temperature
<= 1 % within the supply voltage range
Setting accuracy of time delay 10 P
Time delay drift <= 0.05 % per degree centigrade depending permissible ambient air temperature
<= 1 % within the supply voltage range
Hysteresis 5...50 % adjustable of threshold setting for overcurrent or undercurrent detection
3 % fixed of full scale for window mode
Run-up delay at power-up 0.3 s
Measuring cycle 100 ms measurement cycle as true rms value
Repeat accuracy +/- 0.5 % input and measurement circuit
+/- 2 % time delay
Measurement error < 1 % over the whole range with voltage variation
0.05 %/°C with temperature variation
Response time <= 500 ms on crossing the threshold
Threshold setting 10...100 %
Overvoltage category III conforming to IEC 60664-1
III conforming to UL 508
Insulation resistance > 100 MOhm at 500 V DC conforming to IEC 60255-27

1/4
Insulation Between supply and measurement
Mounting position Any position
Connections - terminals Screw terminals 2 x 0.5...2 x 2.5 mm² - AWG 20...AWG 14, solid cable without cable
end
Screw terminals 2 x 0.2...2 x 1.5 mm² - AWG 24...AWG 16, flexible cable with cable
end
Screw terminals 1 x 0.5...1 x 3.3 mm² - AWG 20...AWG 12, solid cable without cable
end
Screw terminals 1 x 0.2...1 x 2.5 mm² - AWG 24...AWG 14, flexible cable with cable
end
Tightening torque 0.6...1 N.m conforming to IEC 60947-1
Housing material Self-extinguishing plastic
Status LED LED yellow for relay ON
LED green for power ON
Mounting support 35 mm DIN rail conforming to EN/IEC 60715
Electrical durability 100000 cycles
Mechanical durability 10000000 cycles
Utilisation category AC-15 conforming to IEC 60947-5-1
DC-13 conforming to IEC 60947-5-1
AC-1 conforming to IEC 60947-4-1
DC-1 conforming to IEC 60947-4-1
Safety reliability data MTTFd = 296.8 years
B10d = 270000
Contacts material Cadmium free
Width 35 mm
Product weight 0.12 kg

Environment
immunity to microbreaks 50 ms
electromagnetic compatibility Emission standard for industrial environments conforming to EN/IEC 61000-6-4
Immunity for industrial environments conforming to EN/IEC 61000-6-2
Conducted and radiated emissions class B conforming to CISPR 22
Immunity for residential, commercial and light-industrial environments conforming to
EN/IEC 61000-6-1
Electrostatic discharge 6 kV level 3 contact discharge conforming to IEC 61000-4-2
Electrostatic discharge 8 kV level 3 air discharge conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test 10 V/m level 3
conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test 4 kV level 4 direct conforming to IEC
61000-4-4
Electrical fast transient/burst immunity test 2 kV level 4 capacitive coupling
conforming to IEC 61000-4-4
Surge immunity test 4 kV level 4 common mode conforming to IEC 61000-4-5
Surge immunity test 2 kV level 4 differential mode conforming to IEC 61000-4-5
Conducted and radiated emissions class B group 1 conforming to CISPR 11
Emission standard for residential, commercial and light-industrial environments
except radiated emission conforming to EN/IEC 61000-6-3
standards EN/IEC 60255-1
product certifications CCC
CE
CSA
GL
UL
RCM
EAC
China RoHS
ambient air temperature for storage -40...70 °C
ambient air temperature for operation -20...50 °C at 60 Hz
-20...60 °C at 50 Hz AC/DC
environmental characteristic 3K3 level C
relative humidity 93...97 % at 25...55 °C conforming to IEC 60068-2-30
vibration resistance 0.075 mm (f = 10...58.1 Hz) (not in operation) conforming to IEC 60068-2-6
1 gn (f = 10...58.1 Hz) (not in operation) conforming to IEC 60068-2-6
0.035 mm (f = 58.1...150 Hz) (in operation) conforming to IEC 60068-2-6
0.5 gn (f = 58.1...150 Hz) (in operation) conforming to IEC 60068-2-6
shock resistance 15 gn for 11 ms (not in operation) conforming to IEC 60068-2-27
5 gn for 11 ms (in operation) conforming to IEC 60068-2-27

2/4
IP degree of protection IP20 on terminals conforming to IEC 60529
IP50 on front panel conforming to IEC 60529
IP30 on housing conforming to IEC 60529
pollution degree 3 conforming to IEC 60664-1
3 conforming to UL 508
dielectric test voltage 2.5 kV for 1 min AC 50 Hz conforming to IEC 60255-27

Offer Sustainability
Sustainable offer status Green Premium product
RoHS (date code: YYWW) Compliant - since 1524 - Schneider Electric declaration of conformity
REACh Reference not containing SVHC above the threshold
Product environmental profile Available
Product end of life instructions Available

Contractual warranty
Warranty period 18 months

Dimensions

Mounting and Clearance


Rail Mounting

Current Measurement Relay

Wiring Diagram

3/4
A1,A2 : Supply voltage
E1,E2,E3,M : Currents to be measured
11-14,12 : 1st C/O contact of output relay
21-24,22 : 2nd C/O contact of output relay

Function Diagrams

Undercurrent Detection

Without memory ("No Memory" mode)

With memory ("Memory" mode)

Overcurrent Detection

Without memory ("No Memory" mode)

With memory ("Memory" mode)

Legend

Ti Starting inhibition time delay


Tt Time delay after crossing of threshold
Un Supply voltage
I Monitored current
H Hysteresis
I> Overcurrent threshold
I< Undercurrent threshold
11-12/11-14, 21-22/21-24 Output relay connections
Relay status: black color = energized.
NOTE: In "Memory" mode, the relay opens when crossing of the threshold is detected and then stays in that position. The power
supply voltage must be switched off to reset the product.

4/4

You might also like