Antminer
PSU
APW3+-‐12-‐1600
Series
BITMAIN
APW3+-‐12-‐160000
PSU
Series
User
Guide
1
Antminer
PSU
APW3+-‐12-‐1600
Series
Content
1.
Overview
..................................................................................................................
3
2.
Fetures
.....................................................................................................................
3
3.
Specifications
...........................................................................................................
4
4.
Order
Information&
Wire
Type
................................................................................
6
5.
Trouble
Shooting
&FAQ
...........................................................................................
7
6.
Precautions
for
Use
..................................................................................................
8
2
Antminer
PSU
APW3+-‐12-‐1600
Series
1. Overview
The
APW3+-‐12-‐1600
series
AC-‐DC
PSU
combines
high
efficiency
and
good
dynamic
performance
into
a
power
dense
package.
It
also
features
overload,
overheat,
overcurrent
and
low
voltage
protection,
making
it
well
suited
to
12V,
≤1600W
power
devices.
Please
note:
1. This
PSU
cannot
be
used
in
countries
with
a
mains
power
voltage
is
lower
than
205V,
the
PSU
will
not
start
below
this
voltage
2. Fetures
l ±20%
voltage
input
range
l High
efficiency,
up
to
93.5%
l Short
circuit,
overload
and
overheat
protection
l Extreme
power
density,1U
form
factor
l 100%
rated
up
to
50℃
ambient
l C13
power
connector
l ·∙12
Month
Warranty
3
Antminer
PSU
APW3+-‐12-‐1600
Series
3. Specifications
DC
Voltage
12.15V
Rated
Current(220V
input)
133A
Rated
Power
(220V
input)
1600W
Ripple
&
Noise
<1%
Output
Voltage
Regulation
<2%
Source
Regulation
<1%
Load
Regulation
<1%
Setup,
Rise
Time
<5S
Power
off
Protection
Trip
Time
>10mS
Interface
Type
5pairs
of
6pin
PCI-‐E
connectors.
Input
Voltage
Range
176-‐264V
AC
Starting
Voltage
200-‐205V
AC
Frequency
Range
47-‐63Hz
Power
Factor
>0.95(full
load)
Leakage
Current
<1.5mA(220V
50Hz)
Low-‐voltage
Input
134-‐155A
Output
Short
Circuit
Yes
Low-voltage Input
(220V
171-‐181V
AC
input)
Protection
Output
Short
Circuit
Yes
Output
Overcurrent(220V
134-‐155A
input)
Overheat
Protection
Yes
Environment
Operating
Temperature
-‐20-‐60℃
Conditions
Operating
Humidity
20%-‐90%
RH
(non-‐condensing)
Structure
Dimensions
266mm*108mm*41mm
Weight
2.5KG
Fan
force-‐air
cooling
Cooling
Fan
speed
when
temperature
of
the
heat
sink
is
higher
than
80
℃,
the
fan
runs
at
full
speed
4
Antminer
PSU
APW3+-‐12-‐1600
Series
Max
Load
vs.
Ambient
Temperature
Graph
(220V
input)
Current(A)
Max
Load
vs.
Ambient
Temperature
135
130
125
120
115
110
105
100
-‐20
0
20
50
55
60
Temperature ℃
Max
Load
vs.
Ambient
Temperature
Efficiency
vs
Load
(220V
input)
Efficiency Efficiency
94.00%
92.00%
90.00%
88.00%
86.00%
84.00%
82.00%
80.00%
78.00%
10
20
30
40
50
60
70
80
90
100
110
120
130
133
Efficiency
Current(A)
5
Antminer
PSU
APW3+-‐12-‐1600
Series
4. Order
Information&
Wire
Type
4.1 Order
Information
APW3+&12&2600&A1+ + +
+ PSU$Wire$Type$
$ Revision$
$ Rated$Power$(W)$
$ Voltage$Output$(V)$
$ PSU$Model$#+
4.2 Wire
Types
6
pairs
of
6
pin
PCI-‐E
connectors.
450mm
length
for
each
PCI-‐E
6
Antminer
PSU
APW3+-‐12-‐1600
Series
5. Trouble
Shooting
&FAQ
#
Issue
Reason
Troubleshooting
1
Fan
won’t
AC
Input
is
1.
Make
sure
the
AC
input
wire
has
a
good
run,
and
no
abnormal
connection
and
the
plugs
are
connected
firmly
12V
output
2.
Make
sure
the
mains
power
is
working
well
and
its
voltage
is
above
100V.
2
The
fan
is
1.
Voltage
in
1.
Please
check
whether
the
voltage
is
above
100V
running,
but
your
power
with
multimeter
to
make
sure
the
PSU
can
switch
on
there
is
no
system
is
lower
correctly.
12V
output.
than
required
2.
Check
whether
there
is
a
short
circuit
output
or
2.
PSU
is
in
overload
that
is
causing
the
PSU
to
enter
a
locked
protection
status.
After
removing
the
problem,
the
PSU
should
mode
power
up.
3
After
a
few
PSU
is
in
1.Check
whether
the
fan
is
working
minutes,
the
over-‐heat
2.Check
whether
the
fan’s
vent
is
being
blocked
PSU
stops
protection
3.Check
whether
there
is
a
dust
buildup
inside
the
working,
PSU
due
to
prolonged
use.
Do
NOT
remove
the
PSU’s
starts
cover
unless
trained
to
do
so.
working,
4 . Check
the
power
and
ambient
temperatures
stops
working
follows
the
Load/Temperature
graph
and
keeps
cycling.
4
Output
is
Fan
is
broken
1.
Check
that
the
fan
is
clear
of
blockages
or
buildup
normal,
but
2.
Fan
is
broken
and
needs
to
be
replaced.
the
fan
is
not
working.
5
The
PSU
The
PSU
is
in
Check
whether
the
load
current
has
exceeded
the
suddenly
has
over-‐current
built-‐in
overcurrent
protection
limit.
The
protection
no
output
protection.
automatically
triggers
when
the
load
current
and
can’t
be
exceeds
the
limit
to
protect
against
damage
to
the
started
again.
PSU
and
the
miner.
7
Antminer
PSU
APW3+-‐12-‐1600
Series
6. Precautions
for
Use
1.
Before
using
the
PSU,
please
ensure
that
the
voltage
and
power
outputs
are
compatible
with
your
equipment.
2.
Please
ensure
that
the
PSU
appears
to
be
in
good
shape
and
has
not
suffered
damage
in
transit.
If
the
exterior
of
the
PSU
appears
damaged,
do
not
use
it.
3.
Make
sure
that
the
metal
cover
for
the
PSU
with
on/off
switch
is
properly
grounded.
Improper
grounding
is
dangerous.
4.
The
PSU
must
be
installed
in
such
a
way
that
it
receives
good,
unobstructed
airflow.
Under
no
circumstances
should
the
PSU
be
installed
in
an
enclosed
place.
5.
When
installing
the
PSU,
please
double
check
that
the
output
polarities
are
the
correct
way
round,
and
that
the
screws
are
fastened
securely
in
place.
6.
Do
not
attempt
maintenance
on
any
wiring
while
the
PSU
is
powered
up
from
the
mains.
7.
Running
the
PSU
at
<80%
load
or
below
can
greatly
prolong
the
life
of
the
PSU.
Usually,
for
every
10ºC
above
the
rated
amount,
the
life
of
the
PSU
is
cut
in
half.
8