Advancing medical technology to help you, help others.
Experience The Cadwell Difference – Since 1979
    The benefits of owning a Cadwell system are numerous. Our development team understands
    and delivers what you need. Everyone at Cadwell stands behind our products, and we all have
    the same goal - to keep you as a loyal, devoted customer long into the future.
    Innovative Neurodiagnostic Instruments
    John Cadwell, BSEE, MD designed the first microprocessor-controlled EMG instrument. In
    1979, he and his brother Carl, DDS, formed Cadwell Laboratories, Inc. and began selling
    their device. Since then, Cadwell has been a leader in the development and manufacture
    of innovative and reliable instruments for neurophysiology. Many of these instruments
    have been providing decades of service to their owners.
    Numerous patents are held by Cadwell, including those for magnetic stimulators, cable
    shielding designs, neural network analysis of EEG, and database designs. Today, still
    located in Kennewick, Washington, John and Carl continue ownership of the company and
    come to work everyday to develop and market products ranging from EMG to EEG to PSG
    to IONM instrumentation and more. Cadwell has a firm hold of its identity and a dedicated
    focus on neurophysiology.
    Advancing medical technology to help you, help others.
2
Our Most Advanced EMG/EP Instrument (The New Standard)
The Sierra® Summit™ is the latest in a long line of successful Cadwell products. It combines the Sierra Wave’s ease of use with
innovative advancements in acquisition and stimulation technology to offer the most flexible, reliable and clinically functional
system on the market today. The Summit is offered in either a 2, 6, or 12 channel configuration and is proudly designed
and manufactured at our Kennewick, Washington facility. The Summit is built with the same lasting quality and reliability
customers have come to expect from Cadwell.
The Summit can be configured as a portable or desktop system. The portable version comes with a laptop computer and
soft-sided carrying case. The desktop version comes with a desktop PC and an LCD monitor or all-in-one PC. We offer both
lightweight and hospital-grade equipment carts to complete the system.
                                                                                                                    Sierra Summit with
                                                                                                         laptop, two channel amplifier,
                                                                                              and StimTroller Plus™. Also available with
                                                                                 a twelve channel amplifier and second StimTroller Plus.
                                                                                                                                           3
    Standard Features of the Sierra Summit
    • Base Unit with dedicated keypad and 	     • EMG Guided Injection Protocol                 • EMG to AVI Converter (convert EMG to 	
    	 knob controls (requires a computer)       • NCV (motor, sensory, mixed, inching)          	 video/audio files)
    • Dual high-power speaker system 		         • F Wave / H Reflex                             • DataLAB™ (calculate user-defined 	
    	 with software equalizer                   • AnatomyVIEW™                                  	relationships)
    • Handheld StimTroller Plus™                • Side-to-Side Comparisons                      • ASCII Output Utility (all test protocols)
    	 (3 programmable buttons, remote 	         	 (NCV, F, H, EP)                               • CadLink™ Database (management of 	
    	 stim and control)                         • Blink Reflex                                  	 patient files and user settings)
    • 2, 6, or 12 Channel Amplifier 		          • RNS (1 or 2 channel acquisition)              • Compatible with Sierra Wave data 	
    	configurations                             • SEP (upper, lower, dermatomes)                	 files and user settings
    • USB Footswitch                            • Autonomic Studies                             • Internal Calibration Signals
    • EMG protocols (free run and capture 	         - Heart Rate Variability (RR Interval)      • Hardware Diagnostics Suite 		
    	 mode) - Buffer Playback                       - Sympathetic Skin Response (SSR)           	 (diagnostic routines for the amplifier, 	
    	 with audio (up to 10 minutes) - 		        • Programmable Study Lists                      	 electrical stimulator and keypad)
    	 Unlimited Buffer Storage - 		             • Tabular Data Summary View                     • Electrode Continuity Check (built into 	
    	 Programmable Muscle Scoring -             • QuickReport™ MS Word® based report 	          	amplifier)
    	 EMG snapshots within the published 	      	generator                                      • Comprehensive Application Help Topics
    	reports                                    • Auto Findings Composer (automatic 	           • Free Technical Phone Support
    • QEMG                                      	 comparison to norms and creation 	            • Lifetime Software Upgrades
        - MUP Tool                              	 of sentences for NCV, F, H, EMG and EP 	      • Soft-sided Carrying Case
        - Single Motor Unit Analysis            	findings)                                      • Starter Electrode Kit
        - Multi-Motor Unit Analysis             • EP Analysis (add, subtract, average, 	        • Reader Software
        - Interference Pattern Analysis         	 grand average, invert)
                                                                                                      Sierra Summit keypad
    Optional Software                           • VEP – includes LCD calibration sensor
                                                • Advanced Stim/Trigger capability
    • CadLink™ Server Software (centralized 	   • HL7 Interface for EMR connectivity
    	 data storage and administration of 		     • Data Interface Toolkit (API for developers)
    	 user settings for all Summit
    	 acquisition and reader systems on         Optional Hardware
    	 the network)
    • Single Fiber and Macro EMG                • 2nd Electrical Stimulator
    • Motor Unit Number Estimation (MUNE)       • Skin Temperature Probe
       - Assisted Incremental Technique         • Reflex Hammer
       - Multiple Point Stimulation 		          • Trigger Out/In Interface Cable (3.5mm stereo 	
         Technique                              	 to 2x RCA)                                            Summit utilizes durable, color-coded
    • AEP (ABR, MLR, LLR, ERG, VEMP, 		         • Remote Input Box (for 12-channel amplifier)             connectors with protected pins
    	ECochG)                                    • Amp/Stim Switchbox (Injection Studies)
    • P300
     Sierra Summit rear panel
4
Cart Configurations
Point-of-Care
Shown here is a 2-channel Sierra Summit with a laptop computer on the lightweight Point-
of-Care cart. A printer can be placed on the shelf and supplies stored in the bin. Mounting
brackets for an amplifier arm are located on either side of the top shelf. The articulated
arm holds the amplifier, StimTroller Plus and also provides a convenient needle holder. The
placement of the stimulator and needle holder can be reversed. Snap-on cable covers on
the arm protect the amplifier and stimulator cables while providing a clean appearance.
The top shelf height is adjustable via hydraulic lever for use while standing or
sitting. Options include a pull-out keyboard shelf, footswitch holder and an
additional storage bin.
                                                        Amplifer bracket with
                                                        2 channel amplifier,
                                                        stimulator and needle
                                                        holder
Narrow Trolley
Shown here is a 12-channel Sierra Summit with a low profile PC on the
Narrow Trolley cart. This cart features a foam handle and large locking
wheels for easy manuevering. Cable management is provided inside the
trolley’s twin legs. The PC and a printer can both be placed on the large
bottom shelf. The middle shelf holds the Sierra Summit base unit, while
        the top shelf remains free and can be used as a convenient writing
         surface. The LCD monitor mounts on a sturdy, adjustable pole on
         the rear of the top shelf. An optional isolation transformer can be
         installed on the basement shelf. Other options include a pull-
         out keyboard/mouse tray, storage drawer and an accessory bag
         which mounts on the back of the cart.
                 Don’t need a cart? The Sierra Summit, amplifier,
                 StimTroller Plus and cables all fit into our custom
                                   carrying case. For even greater
                                       portability, upgrade to the wheeled
                                       carrying case.
                                                                                              5
    Multi-Modality Configuration
    Maximize your diagnostic offerings by configuring Easy III EEG and
    Sierra Summit EMG/EP software on the same PC. Pictured here are
    the 12-channel Sierra Summit and 32-channel Easy III amplifiers on a
    Narrow Trolley cart. An all-in-one computer frees up the bottom shelf
    for a large printer or additional storage space.
    Hardware Diagnostics
    The Sierra Summit includes a comprehensive hardware
    diagnostic suite. Reduce troubleshooting time by easily
    verifying the proper performance of the amplifier, electrical
    stimulators and base unit keypad. You can save or print the
    test results for your maintenance notebook. Calibration
    signals, with four voltages and two frequency settings, are also
    available in all test protocols.
                                                                            NCV Test Protocol
                                                                            EMG Test Protocol
6
Amplifiers
Cadwell has long been recognized as producing some of the world’s finest
neurophysiologic amplifiers; and the Sierra Summit amplifiers are no exception.
Either 2-, 6-, or 12-channel configurations are available. The same amplifier is utilized for
the 6-channel configuration, with the maximum number of channels limited by software.
Each amplifier features fast artifact recovery and very low noise. Analog-to-digital
conversion is done inside the amplifier, eliminating the amplifier cable as a potential
noise source. Each amplifier has superb RF immunity and excellent signal quality.
Temperature measurement, impedance, on/off switch and calibration signals are built-
in. The 12-channel amplifier has four non-switched and eight switched channels. The
eight switched channels can use any of the 20 inputs available in the modified
head pattern on the amplifier or optional remote input box. All 12 channels
can be used simultaneously for data acquisition.
                              A unique electrode continuity check
                              (Electrode Check) is built into each
                              amplifier, so you can easily confirm if
                              one of your electrode leads is good
                              or bad.
StimTroller Plus™                                     Programmable Button 3                        Removable/Adjustable Angle
Programmable Stimulator and Test Controller                                                        Stimulator Probes
The StimTroller Plus reduces test time by providing
                                                                                                   Quick Connect Area
commonly used functions on the remote handheld stimulator.
A typical study can be performed without having to reach back                                      Polarity Indicator
to the base unit keypad or mouse. Three programmable buttons
allow customization to suit your technique.
Functions include:
• Single or repetitive     • Playback of EMG buffer                                             Reverse Polarity Button
	 pulse delivery           • Probes can be removed to connect
• Polarity reversal          standard bar and ring electrodes. 			
                                                                Angle                           Single Stim / Hold for Repetitive
                           	 Or leave probes in and use our 			 Adjust
• Intensity adjust                                              Button                          Intensity Adjust / Distance Wheel
                           	 Quick Connect Adapter. Other
• Trace storage            	 probe styles include:
• Distance entry              - Small diameter, round tip                                       Store
• Next test                   - Large diameter, pointed tip
                              - Felt pad tip
• Start/stop EMG              - Large diameter, round tip (shown here)
	acquisition
                           • Adjustable stimulus probe angle
• Store EMG snapshot         and width for easier and faster
• EMG gain control         	 access to all stimulus locations
                                                                                                Programmable Buttons 1 and 2
• Move back and forth      • Three programmable buttons can be
  within EMG buffer          assigned test specific functions.
                                                                                                                                    7
    User Interface
    Clean, reliable and fast best describe the Sierra Summit user interface. Use either the custom keypad with its function keys and soft
    knobs, or the mouse - whichever is most convenient for you. Combined with the StimTroller Plus and programmable footswitch,
    you have all the controls you need without having to drill down through seemingly endless menus.
    Advanced features are available from the pull-down menus at the top of the screen or by accessing the context menu (mouse
    right-click) over each window. A plug-and-play USB communication interface to the Summit base unit provides compatibility and
    upgradeability in a rapidly changing PC environment.
                                       F key and soft knob functionality are specifically tailored for each test
                                       protocol to maximize ease of use and facilitate rapid data acquisition
8
 Software
Standard EMG protocol includes both Live and Capture data acquisition modes with easily accessible muscle scoring table and
audio equalizer controls, allowing you to fine tune the audio signal to your listening preference. Up to 10 minute Live EMG Buffer
with unlimited storage and playback. Full-screen or raster displays. Manual MUP tool and single Motor Unit Analysis for quick
documentation of interesting motor unit potentials.
Spontaneous or Stimulated Single Fiber Analysis using either
real-time peak latency detection or voltage crossing. Records
up to 100 consecutive discharges and displays #blocks, MCD,
IPI, and frequency. Review and editing can be done real-time or
offline. A Fiber Density calculator is included.
Interference Pattern Analysis: Quantifies the electromyographic
interference pattern and displays the results on color-coded           Multi-MUP Analysis: Signal decomposition and template
plots. Analysis includes Amplitude vs. Turns, Envelope vs. Activity,   matching is used to extract, identify, and sort motor unit action
and Number of Short Segments vs. Activity. Normative reference         potentials from an epoch of EMG. Typically 1 to 6 motor units
“clouds” provided for several muscles. IPA provides a basis for        can be extracted from one 10 second epoch. Includes flexible
classifying the interference pattern as normal, neuropathic, or        editing features and summary display of all acquired MUPs. Can
myopathic. Can be performed real-time or offline.                      be performed real-time or offline.
                                                                                                                                           9
 Automatic cursor placement and Left vs. Right comparisons in NCV, F, H, and Evoked Potential test protocols. Live Monitor window
 facilitates identification of artifacts or poor electrode connections. On-line comparison to reference data and identification of
 abnormal values. Unlimited number of traces displayed per test protocol.
                                                                        Unique Tab Data Summary View provides quick and
                                                                        convenient review on all acquired traces and tabular results.
                                                                        Adjust cursor positions, change distance measurements, and
                                                                        easily review and playback stored EMG without having to return
                                                                        to the specific test protocol. Cadwell’s unique Auto Findings
                                                                        Composer compares the patient’s values to your norms and
                                                                        creates findings sentences for NCV, F, H, EMG, and EP’s.
                                                                        AnatomyVIEW feature displays the EMG muscle scoring and
                                                                        NCV results on a 3D color-coded anatomical model. Green
 Repetitive Nerve Stimulation by manual or automatic delivery           indicates normal findings and varying levels of yellow-orange-
 of programmable stimulus trains. Results include comparison of         red indicate abnormal results. The models can be rotated and
 both amplitude and area for all responses in the train. Supports       resized quickly using the mouse. This graphic can be included
 stimulation frequency up to 50 Hz and 1 or 2 channel recording.        in reports.
10
Evoked Potentials include somatosensory, auditory, and visual modalities with display and storage of unlimited number of waveforms.
Auto-cursors for marking important waveform features with automatic side-to-side comparison and highlighting of abnormal values.
Normal or Odd/Even averaging modes. Adjustable artifact rejection and support for third-party stimulators via Trigger In/Out.
Cadwell’s industry leading Report Generator utilizes Microsoft
Word® and includes customizable modules for entry of patient
history, physical exam, impressions, and more, without having
to type at the keyboard. Reports include tabulated data,
waveforms, anatomical displays, and results of Auto Findings
Composer. Templates can be customized to suit your individual
needs.
Autonomic Studies include RR interval and Sympathetic Skin            Advanced Studies include Macro EMG, MUNE (motor unit
Response. RR Interval includes automatic or manual calculation        number estimation) and multiple stimulus configurations
of max/min ratio and support for normal and deep breathing,           utilizing the two independent electrical stimulators with
valsalva maneuver, and 30:15 ratio.                                   adjustable train lengths and delays.
                                                                                                                                  11
     CadLink™ Database
     Designed for easy setup and operation in either the private practice or large neurodiagnostic laboratory setting, the CadLink
     database organizes, manages and secures your patient files and customized user settings. View your patient records in multiple ways
     - alphabetically, by day, by month, by year, by physician - whichever is convenient. Complex searches can be accomplished using the
     advanced search capabilities. Import supplementary documentation, such as symptom drawings, pictures or patient history forms and
     save them with the record. CadLink supports multiple users; each with their own test settings and report templates.
     Networking
     Add the CadLink Central Server module and you can seamlessly network multiple Sierra Summits and Reader stations. Patient
     records are available from any acquisition or review station on the network. Complete the exam and then finish the report later in the
     comfort of your office. The receptionist can also be included on the network so that patient information can be input at check-in or
     final edits can be made to reports. Change a test setting or report template on one Sierra Summit and it is automatically available to
     all systems on the network.
                                             Exam Room 1                             Reception
                                                                     Server
                                                                              Reader station in
                                            Exam Room 2                       physician’s office
12
Your Time is Valuable
Here Are Three Reasons the Sierra Summit Will Save You Time
                                           1. Reduced Testing Time
                                              • Perform NCV, F/H tests without touching
                                              	 the keypad.
                                              	 Select nerves, acquire traces, store traces, and enter 		
                                              	 distances using programmable buttons on the StimTroller Plus.
                                              • Easier access to stim locations.
                                              	 Angle of stimulus probes is adjustable and the
                                              	 polarity of the probes is reversible. And with our
                                              	 Quick Connect Adapter, you don’t need to
                                              	 remove the probes to attach a bar or ring electrode.
                                              • Eliminate the time of moving between screens.
                                              	 Study lists allow you to perform a complete study from 			
                                              	 one screen, saving button pushes and time.
                                              • Adapts to your testing style.
                                              	 Most functions can be performed using button pushes or the 		
                                              	 mouse. You decide which makes you more efficient.
2. Rapid Review of Results
  •	One button push displays all data.
  	 Numbers and waveforms from every 	
  	 test are available from one screen. Click 	
  	 on a test to review the waveforms or 	
  	 adjust cursors.
  •	Faster data review.
  	 Abnormal findings
  	 (based on your 		
  	 normal values) are  	
  automatically 				
  	 highlighted but can
  	 be adjusted if needed for each patient.
  •	Eliminates the time it takes to write a 	
  	 summary paragraph.
  	 Auto Findings Composer writes the
  	 summary of findings paragraph for you
  	 based on the highlighted values you
  	 have determined to be abnormal in
  	 both NCV and EP tests, and even 		
  	 summarizes your EMG scoring for                                Finding shown here in bulleted format.
  	 the report.                                                 Numbered or paragraph formats also available.
                                                                                                                13
     3. Your Personalized Reports without Typing
       •	Unique Reports.
       	 We will design templates in your own style, not 	
       	 ours. Templates 	can be designed for EMG/
       	 NCV testing only or even more complex full 	
       	 consultation reports.
       •	Eliminate dictation or typing.
       	 Your custom report templates will allow you to
       	 generate reports simply by using the mouse and 	
       	 selecting from a list of choices.
                                                                                                           Use the mouse to
       •	Easily email reports.
                                                                                                           make selections
       	 All results and findings are automatically 		
       	 transferred to Microsoft Word, and are saved in 	
       	 *.doc, *.docx, or *.pdf format.
       •	EMR friendly.
       	 Easy integration with patient’s electronic          The Carpal Tunnel Impression template has been selected.
       	 medical record. Sierra Summit is network ready 	
       	 and has an optional HL7 Interface.
      Easily insert your
          office header
               and logo.
  This entire section
 was created without
 using the keyboard.
                                                                                       All result tables can be included with
                                                                                       abnormal values highlighted.
                                                                                       Waveforms optionally included.
14
Cadwell Customer Support
Cadwell is focused on making you a satisfied, loyal customer for years to come. Our
telephone support is second to none. We answer every call during business hours
with a real person. Our in-house employee technicians are trained professionals.
Our web-based support program allows our technicians to troubleshoot real-time
– as if they were in your office. Our flexible service contracts will meet your specific
needs. Just ask.
Supplies and Accessories - www.estore.cadwell.com
Cadwell has a complete range of quality, reliable supplies as well. From Monopolar and Concentric to Injectable and Single
Fiber needles; disposable and reusable surface electrodes for NCV, EMG and EP. We are your one-stop source for everything
neurophysiology related.
              Quick Connect                                                                      Shielded Interconnect
                Adapter                                                                                  Cable
                                                 Cadwell Disposable Patient Pak Refills
                                                            and Starter Kits
                                                         (Improved Hydrogel)
                                                                                                       Stim Probe
      Ambu® Neuroline Disposable                                                                       Extension
      Monopolar Needle Electrodes
       With Detached Lead Wire
                                                                                                                             15
909 N. Kellogg St. · Kennewick, WA 99336
(800) 245-3001 · (509) 735-6481 ph · (509) 783-6503 fx
www.cadwell.com · info@cadwell.com
© 2013 Cadwell. All rights reserved.                                                                                                                                        PN# 190272-937 Rev. 00
The information contained in this document is subject to change without notice. This document contains trademarks that belong to Cadwell Laboratories, Inc. and other companies, respectively.