Service Information Letter
SIL Number: 606-00083-010
                       To: Owners/Operators of Avidyne Release 9-equipped aircraft
                   Subject: Boot-up and GPS Receiver Loading Errors
                        This Service Information Letter (SIL) advises owners and operators
                        of Avidyne Entegra Release 9-equipped aircraft of three issues.
                           1.) When starting up Release 9 there are cases where the IFDs
                               do not start-up completely.
               Purpose:    2.) During the Release R9.2.1 upgrade the GPS receiver
                               software may not load correctly. In these instances, the GPS
                               receiver will become non-functional.
                           3.) Only primary flight information is displayed due to software
                               scheduling conflict.
               Revision: 01                                                 Date: 09/09/2011
Problem Description
   1) This Service Information Letter (SIL) advises owners and operators of Avidyne Entegra Release 9-
      equipped aircraft that there is a possibility that an IFD will power up with only the upper half
      displayed. This problem is caused by an internal system safety mechanism which determines there
      is a performance issue with the software controlling the lower half of the display screen.
    2) During the field-loading process of updating the GPS receiver, there have been reports of receivers
       that have not accepted the Release 9.2.1 software update. If the GPS receiver does not
       successfully accept the software update, the GPS will not operate and a new software load is not
       possible in the field. The GPS receiver must be returned to Avidyne for repair.
    3) On very rare occasions the lower half of an IFD is removed due to a strict software scheduling
       design issue that causes a software partition to shut down. When this timing issue occurs the
       higher priority software remains displayed (this is the upper half primary flight information), while the
       lower priority software, (FMS, moving map, engine instruments, checklists, etc,) is removed in order
       to not present false or misleading information.
Solution
   1) The start-up failure only has occurred during the first sixty seconds of IFD operation. The problem
       has not yet been observed after the first sixty seconds or during normal operation of the units. In
       the event that the lower half of the IFD screen fails to appear following power-on, the failing IFD
       should be reset.
Revision: 01                                                                                       606-00083-010
Date: 09/09/2011                                                                                       Page 1 of 2
                                              Service Information Letter
    2) The GPS loading failure can only be resolved by returning the GPS receiver blades to Avidyne for
       repair. Avidyne will correct the issue on your blade or provide an exchange, if one is available. It is
       encouraged for the installer to install the R9.2.1 or R9.2.3 software prior to the DFC100 work just in
       case the GPS blade experiences this issue.
    3) This timing issue has been resolved in the R9.2.3 software. It is recommended that installers
       upgrade to R9.2.3 at the next opportunity.
Effectivity
     Description                       IFD5000
     Avidyne Part Number               700-00083-()
    Avidyne Software Release           Release 9.0, 9.0.1, 9.0.2, 9.0.2.1, 9.1, 9.1.1, 9.2, 9.2.1, 9.2.2
Only Release 9 software version R9.2.1 is affected by the bootup anomaly. All Release 9 software
versions (9.0.0, 9.0.1, 9.0.2, 9.0.2.1, 9.1, 9.1.1, 9.2) are affected by the GPS receiver loading anomaly and
the scheduling anomoly. The resolution to these issues have been included in the next release, R9.2.3 or
R9.3.
Contact Information:
Any customer who experiences the symptoms described above can contact the Avidyne Entegra Release
9 Hotline.
Avidyne Entegra Release 9 Hotline: 1-877-MyAVIR9 (1-877-692-8479)
Revision: 01                                                                                       606-00083-010
Date: 09/09/2011                                                                                       Page 2 of 2