MODEL LIGHTING LT 1 2/2/2021
Site 1 / LANTAI 1 / Storey 1 / Philips DN130B D217 1xLED20S/840 1xLED20S/840/- / Philips - DN130B D217 1xLED20S/840
(1xLED20S/840/-)
Philips DN130B D217 1xLED20S/840 1xLED20S/840/-
CoreLine Downlight – for every project, where light really matters
CoreLine Downlight delivers on the CoreLine promise of innovative,
easy to use and high-quality luminaires. The CoreLine Downlight
range of recessed luminaires is designed to replace CFL-ni/CFL-i
based downlight luminaires. Their attractive TCO helps customers to
make the switch to LED. These luminaires create a natural lighting
effect for use in general lighting applications. They also deliver instant
energy savings and have a much longer lifetime, creating a real value-
for-money and environmentally friendly solution. They are easy to
install thanks to their standard cut-out size and push-in connectors.
InterAct Ready luminaires with integrated wireless communications in
this family available, to be used with InterAct gateways, sensors and
software.
Light output ratio: 91.13%
Lamp luminous flux: 2500 lm
Luminaire luminous flux: 2278 lm
Power: 22.0 W
Luminous efficacy: 103.6 lm/W
Colorimetric data
1xLED20S/840/-: CCT 3000 K, CRI 100
Luminous emittance 1 / Polar LDC
105° 105°
90° 90°
75° 75°
60° 200 60°
300
45° 45°
400
500
30° 15° 0° 15° 30°
cd/klm η = 91%
C0 - C180 C90 - C270
Page 1
MODEL LIGHTING LT 1 2/2/2021
Site 1 / LANTAI 1 / Storey 1 / Philips DN130B D217 1xLED20S/840 1xLED20S/840/- / Philips - DN130B D217 1xLED20S/840
(1xLED20S/840/-)
Luminous emittance 1 / Linear LDC
500
400
300
200
100
90.0° 67.5° 45.0° 22.5° 0.0° 22.5° 45.0° 67.5° 90.0°
cd/klm η = 91%
C0 - C180 C90 - C270
Luminous emittance 1 / Cone diagram
E(0°) 4556
0.50 1.0 E(C0) 45.9° 768
E(0°) 1139
1.0 2.1 E(C0) 45.9° 192
E(0°) 506
1.5 3.1 E(C0) 45.9° 85
E(0°) 285
2.0 4.1 E(C0) 45.9° 48
E(0°) 182
2.5 5.2 E(C0) 45.9° 31
E(0°) 127
3.0 6.2 E(C0) 45.9° 21
Distance [m] Cone diameter [m] Illuminance [lx]
C0 - C180 (Beam angle: 91.8°)
Page 2
MODEL LIGHTING LT 1 2/2/2021
Site 1 / LANTAI 1 / Storey 1 / Philips DN130B D217 1xLED20S/840 1xLED20S/840/- / Philips - DN130B D217 1xLED20S/840
(1xLED20S/840/-)
Luminous emittance 1 / Luminance diagram
C225 C180 C135
C270 C90
16000
24000
C315 C0 C45
cd/m²
g = 65.0° g = 75.0° g = 85.0°
Luminous emittance 1 / UGR diagram
Glare evaluation according to UGR
ρ Ceiling 70 70 50 50 30 70 70 50 50 30
ρ Walls 50 30 50 30 30 50 30 50 30 30
ρ Floor 20 20 20 20 20 20 20 20 20 20
Room size Viewing direction at right angles Viewing direction parallel
X Y to lamp axis to lamp axis
2H 2H 26.7 27.8 27.0 28.0 28.2 26.7 27.8 27.0 28.0 28.2
3H 26.9 27.9 27.2 28.2 28.5 26.9 27.9 27.2 28.2 28.5
4H 27.0 28.0 27.3 28.2 28.5 27.0 28.0 27.3 28.2 28.5
6H 27.1 28.0 27.5 28.3 28.6 27.1 28.0 27.5 28.3 28.6
8H 27.1 28.0 27.5 28.3 28.6 27.1 28.0 27.5 28.3 28.6
12H 27.2 27.9 27.5 28.3 28.6 27.2 27.9 27.5 28.3 28.6
4H 2H 26.9 27.8 27.2 28.1 28.4 26.9 27.8 27.2 28.1 28.4
3H 27.2 28.0 27.6 28.3 28.7 27.2 28.0 27.6 28.3 28.7
4H 27.4 28.1 27.8 28.4 28.8 27.4 28.1 27.8 28.4 28.8
6H 27.6 28.2 28.0 28.5 28.9 27.6 28.2 28.0 28.5 28.9
8H 27.6 28.2 28.1 28.6 29.0 27.6 28.2 28.1 28.6 29.0
12H 27.7 28.2 28.1 28.6 29.0 27.7 28.2 28.1 28.6 29.0
8H 4H 27.4 28.0 27.8 28.4 28.8 27.4 28.0 27.8 28.4 28.8
6H 27.7 28.1 28.1 28.5 29.0 27.7 28.1 28.1 28.5 29.0
8H 27.8 28.2 28.3 28.6 29.1 27.8 28.2 28.3 28.6 29.1
12H 27.9 28.2 28.4 28.7 29.2 27.9 28.2 28.4 28.7 29.2
12H 4H 27.4 27.9 27.8 28.3 28.7 27.4 27.9 27.8 28.3 28.7
6H 27.7 28.1 28.1 28.5 29.0 27.7 28.1 28.1 28.5 29.0
8H 27.8 28.1 28.3 28.6 29.1 27.8 28.1 28.3 28.6 29.1
Variation of the observer position for the luminaire distances S
S = 1.0H +0.4 / -0.6 +0.4 / -0.6
S = 1.5H +0.9 / -1.7 +0.9 / -1.7
S = 2.0H +2.0 / -3.1 +2.0 / -3.1
Standard table BK02 BK02
Correction Summand 9.5 9.5
Corrected glare indices referring to 2500lm Total luminous flux
The UGR values are calculated in acc. with CIE Publ. 117. Spacing-
to-height ratio = 0.25
Page 3