0% found this document useful (0 votes)
72 views114 pages

ATEXE Web

The document provides information about SMC's ATEX compliant products, including pneumatic equipment like solenoid valves, cylinders, and rotary actuators. It outlines the ATEX directive requirements and certification procedures for electrical and non-electrical equipment. SMC offers a wide range of products certified under ATEX directives for use in hazardous environments.

Uploaded by

Agustino Sando
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
72 views114 pages

ATEXE Web

The document provides information about SMC's ATEX compliant products, including pneumatic equipment like solenoid valves, cylinders, and rotary actuators. It outlines the ATEX directive requirements and certification procedures for electrical and non-electrical equipment. SMC offers a wide range of products certified under ATEX directives for use in hazardous environments.

Uploaded by

Agustino Sando
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 114

SMC guide to ATEX compliant products

ATEX Directive
Directive 94/9/EC
Equipment and Protective Systems intended for use in potentially Explosive Atmospheres

Outline of ATEX directive


Since 1st July 2003, equipment used in potentially explosive atmospheres within the EU is required to comply with the ATEX
directive.

CE Marking and ATEX


All equipment within the scope of the Directive must bear the CE marking and comply with the directive's requirements. ATEX
Directive incorporates conventional European standards for explosion-proof equipment.

Objective of the ATEX Directive


Major objective of the ATEX Directive is as follows:
Preventing electrostatic discharge Preventing ignition likely to be caused by electrical sparks generated from friction,
shock, and wear Preventing ignition under the influence of elevated temperatures due to friction, shock, and wear
Concentrating on the duties of the manufacturers Certifying equipment to the ATEX directive by Zone/Category

Zone/Category classification
The ATEX directive defines the categories of equipment and protective systems, which can be used in the corresponding zones
as per the following table:
Zone 2 Zone 1
Category 3 Category 2
Zone 0
Presence of the explosive Category 1
Zone Equipment category
atmosphere

Continuously or for long periods


0 1 >1000 hours/year

Occasionally
1 2 10 to 1000 hours/year

Rarely or for short periods


2 3 <10 hours/year

SMC's Support
SMC's products corresponding to ATEX Directive
SMC's products which are within the scope of the ATEX Directive include electrical equipment and mechanical equipment such
as pneumatic actuators (cylinders). SMC prepares pneumatic equipment for all industries compliant with the ATEX Directive to
help our customers make a system corresponding to the Directive.

Certification Procedure
Our products are categorized as electrical and non-electrical products, and tested and certified as follows:
Electrical products Non-electrical products
( Solenoid valve, auto switch, serial transmission
system, electro-pneumatic positioner, etc. ) (Cylinder, rotary actuator, etc.)

ATEX
Certification method Certified by Certification method Certified by
Category
1. Technical file Certification authority 1. Technical file Certification authority
Category 1 2. Quality audit Certification authority 2. Quality audit Certification authority
3. Type approval test Certification authority 3. Type approval test Certification authority
1. Technical file Certification authority 1. Technical file SMC
Category 2 2. Quality audit Certification authority (to be stored in the certification authority)
3. Type approval test Certification authority 2. Quality: In-house manufacturing control SMC

1. Technical file SMC 1. Technical file SMC


Category 3
2. In-house production control SMC 2. In-house production control SMC

1
INDEX
<Note for ordering ATEX compliant products>
Some items may not be compliant with the ATEX Directive. For details, refer to How to Order.
For Self Declaration of Conformity, refer to our sales representative.

List of ATEX compliant products


Category
Page no.
1 2 3
Pneumatic 5 Port Solenoid Valve: 52-SY5000/7000/9000  3
Solenoid Valve 5 Port Solenoid Valve: 56-VQC1000/2000/4000  23

Serial Transmission System Integrated Type: For Input/Output: 56-EX250  29


Decentralized Serial Wiring (GW system, 4 branches): 56-EX500  30

Air Cylinder Air Cylinder: 55-C76  33


ISO Cylinder: 55-C85  40
ISO Cylinder: 55-C95 (Bore sizes: 160, 200, 250)  43
ISO Cylinder: 55-C96  45
ISO Cylinder: 55-CP96  50
IISO Cylinder: 55-C55  54
Air Cylinder: 55-CG1  55
Air Cylinder: 55-CS1  57
Compact Cylinder: 55-CQ2  60
Dual Rod Cylinder: 55-CXS  64
Mechanically Jointed Rodless Cylinder/Basic Type: 55-MY1B  66
Mechanically Jointed Rodless Cylinder/Slide Bearing Guide Type: 55-MY1M  67
Mechanically Jointed Rodless Cylinder/Linear Guide Type: 55-MY1H  68

Auto Switch Solid State Switch  69


Reed Switch  69

Rotary Actuator Rotary Actuator: 55-CRB1  88


Rotary Actuator: 56-CRB1  89
Rotary Actuator: 55-CRB2  90
Rotary Actuator: 56-CRB2  91
Rotary Actuator/Free Mount Type: 55-CRBU2  92
Rotary Actuator/Free Mount Type: 56-CRBU2  93
Compact Rotary Actuator: 55-CRQ2  94
Compact Rotary Actuator: 56-CRQ2  95

Booster Regulator Booster Regulator: 56-VBA  96

Pressure Switch 2-Color Display Digital Pressure Switch: 56-ISE70/75 (H)  97

2 Port Valve for Fluid Control Steam Valve: 56-VND  99

Process Valve Valve for Water and Chemical Base Fluids (2/3 port air operated valve): VCC  100
Air Operated Chemical Valve/Threaded Type: 55-LVA  102
Process Pumps/Automatically Operated Type (Internal switching type)
Air Operated Type (External Switching Type): 55-PA3000/5000  104
Air Operated Type (External Switching Type): 56-PA3000/5000  105

Instrumentation Equipment Pneumatic-Pneumatic Positioner: 55-IP5000/5100  106


Pneumatic-Pneumatic Positioner: 56-IP5000/5100  107
Electro-Pneumatic Positioner: IP6000-X14/IP6100-X14  108
Electro-Pneumatic Positioner: IP8000-X14/IP8100-X14  111
Smart Positioner: 52-IP8001/52-IP8101  112
Cylinder Positioner: 56-IP200  113

2
ATEX Compliant
5 Port Solenoid Valve

Series
0344
52-SY
II 2G Ex ia IIC T4...T5 Gb X Ta−10°C to 50°C
II 2G Ex ia IIC T6 Gb X Ta−10°C to 45°C

How to order

52 SY 5 1 2 0 L 3 01 F
Bracket
ATEX Nil Without bracket
category 2 F1 With foot bracket Note 1)
F2 With side bracket
Series
Note 1) 2 position single
5 52-SY5000
solenoid valve only.
7 52-SY7000 Note 2) 52-SY9000 has no
9 52-SY9000 bracket.

Type of actuation Thread type


1 2-position single Nil Rc
2 2-position double F G
3 3-position closed centre N NPT
4 3-position exhaust centre T NPTF
5 3-position pressure centre
A, B port size (Body ported type)
Piping type Symbol Port size Applicable series
2 Body ported type 01 1/8
4 Base mounted type C4 One-touch fitting for ø4
C6 One-touch fitting for ø6
Pilot type C8 One-touch fitting for ø8 52-SY5000
N3 One-touch fitting for ø5/32"
Nil Internal pilot
N7 One-touch fitting for ø1/4"
R Note) External pilot
N9 One-touch fitting for ø5/16"
Note) Base mounted type only.
02 1/4
C8 One-touch fitting for ø8
Barrier
C10 One-touch fitting for ø10 52-SY7000
Nil Without barrier N9 One-touch fitting for ø5/16"
A Z728.H N11 One-touch fitting for ø3/8"
B MTL728P+ 02 1/4
D MTL5021 03 3/8
F KFD0-SD2-Ex1.1065 C8 One-touch fitting for ø8
Note) One barrier per solenoid supplied. C10 One-touch fitting for ø10 52-SY9000
Additionally, when the barrier is selected,
C12 One-touch fitting for ø12
the barriers equivalent to the number of
solenoids are included with the product. N9 One-touch fitting for ø5/16"
N11 One-touch fitting for ø3/8"
Electrical entry Port size (Base mounted type)
L Plug connector type Symbol Port size Applicable series
LL Plug connector with cover type Nil Without sub-plate
TT Cable type 02 1/4 52-SY5000
02 1/4
52-SY7000
03 3/8
Lead wire length 3/8
03
3 300 mm 52-SY9000
04 1/2
6 600 mm
10 1000 mm
15 1500 mm
Manual override
20 2000 mm Nil Non-locking push type
30 3000 mm D Push-turn locking slotted type
100 10000 mm (Semi-standard) E Push-turn locking lever type
∗ L type has 300 mm and 600 mm only.

3
ATEX Compliant
5 Port Solenoid Valve Series 52-SY

Specifications Safety Instructions


1) This product is not suitable for Zone 0. The suitable zones are Zones 1 and 2.
2) SMC-TAS and TAV Series, antistatic tubing, are available if required.
Series 52-SY5000 52-SY7000 52-SY9000 3) The solenoid valve has polarity. Confirm the correct polarity by observing the
Ambient and fluid Temperature class T6 –10 to 45°C (No freezing) color of the lead aires. if the polarity is reversed, the barrier may be damaged.
temperature 4) Confirm that the solenoid input voltage at the lead wires is 10.8 VDC (min).
Temperature class T4, T5 –10 to 50°C (No freezing)
5) This product must be connected to an appropriate barrier (ATEX compliant
Coil temperature rise 40°C less (at rated) product), or a certified intrinsically safe circuit, with the following maximum
Barrier input voltage (non hazardous area) 24 VDC (system rated voltage) at 1.1 W values.
Ui = 28 V
Coil rated voltage (hazardous area) 12 VDC at 0.52 W li = 225 mA (resistively limited)
Pi = 1 W
Intrinsically safe ia Ci = 0 nF
Gas group IIC Li = 0 mH

Protection L type Plug connector type IP30 (LL type : IP40)


rating TT type Cable type IP65
Note) Impact resistance: No malfunction resulted from the impact test using a
Response time
drop impact tester. The test were performed one time Response time (ms) (0.5 MPa)
Type of actuation
each in the axial and right angle directions of the main 52-SY5000 52-SY7000 52-SY9000
valve and armature, in both energized and 2-position single 26 or less 38 or less 50 or less
de-energized states (Valve in the initial stage).
Vibration resistance: No malfunction occurred in a one-sweep test between 2-position double 22 or less 30 or less 50 or less
8.3 and 2000Hz. The test was performed for both 3-position 38 or less 56 or less 70 or less
energized and de-energized states in the axial and
Note 1) According to dynamic performance test JIS B8375-1981.
right angle directions of the main valve and armature
Note 2) Response time when barriers were combined with a valve.
(valve in the initial stage).
Note 3) When system D is used, the ON time is delayed 17 ms more than
response time in table.
Standard SY manifolds Types 20, 41, 42 are used for 52-SY valves. System A: Valve + Z728.H
B: Valve + MTL728P+
D: Valve + MTL5021
F: Valve + KFD0-SD2-Ex1.1065

Manifold Specifications for 20 Type

Model SS5Y5-20 SS5Y7-20


Manifold Specifications for 20 Type
Applicable valve 52-SY520 52-SY720
Port size Flow characteristics
Manifold style Single base / B mounting
Model 1,5,3 4,2 1  4/2 (P  A/B) 4/2  5/3 (A/B  EA/EB)
1 (SUP) / 3/5 (EXH) Common SUP / Common EXH
(P,EA,EB) (A,B) c[dm3/(s·bar)] b Cv c[dm3/(s·bar)] b Cv
Valve stations 2 to 20 (1)
SS5Y5-20 1/4 C8 1.90 0.28 0.48 2.20 0.20 0.53
4/2 (A/B) Location Valve
SS5Y7-20 1/4 C10 3.60 0.93 3.60 0.93 0.27 0.88
1,3,5 (P,EA,EB) Port 1/4
1/8 Note) Values for 5 stations manifold with a 2 position single type valve.
Port size C4 (One-touch fitting for ø4) 1/4
4,2 (A,B) Port C8 (One-touch fitting for ø8)
C6 (One-touch fitting for ø6)
C10 (One-touch fitting for ø10)
C8 (One-touch fitting for ø8)
Manifold base weight W (g) n: Station W = 36n + 6 W = 43n + 64
Note 1) For more than 10 stations (more than 5 stations in case of SS5Y7),
supply pressure to P port on both sides and exhaust from EA/EB port
on both side.
Note 2) 52-SY920 valve are not available with manifold as standard.

Manifold Specifications for 41 and 42 Type


Manifold Specifications for 41 and 42 Type
Port size Flow characteristics
Model 1,5,3 4,2 1  4/2 (P  A/B) 4/2  5/3 (A/B  EA/EB)
Model SS5Y5-41 SS5Y5-42 SS5Y7-42
(P,EA,EB) (A,B) c[dm3/(s·bar)] b Cv c[dm3/(s·bar)] b Cv
Applicable valve 52-SY540 52-SY740
SS5Y5-41 1/4 C8 1.80 0.23 0.44 1.90 0.16 0.45
Manifold style Single base / B mounting
SS5Y5-42 1/4 C8 1.90 0.20 0.46 1.90 0.12 0.43
1 (SUP) / 3/5 (EXH) Common SUP / Common EXH
(1) SS5Y7-42 1/4 C10 3.00 0.25 0.75 3.00 0.12 0.66
Valve stations 2 to 20
Note) Values for 5 stations manifold with a 2 position single type valve.
4/2 (A/B) Location Base
Porting spec. Direction Side
1,3,5 (P,EA,EB) Port 1/4 1/4
Port size 1/8 1/4
1/4
4,2 (A,B) Port C6 (One-touch fitting for ø6) C6 (One-touch fitting for ø6) C10 (One-touch fitting for ø10)
C8 (One-touch fitting for ø8) C8 (One-touch fitting for ø8)
Manifold base weight W (g) n: Station W = 61n + 101 W = 79n + 127 W = 100n + 151
Note 1) For more than 10 stations (more than 5 stations in case of SS5Y7),
supply pressure to P port on both sides and exhaust from EA/EB port
on both side.
Note 2) 52-SY940 valve are not available with manifold as standard.
Note 3) 52-SY series are not available with resin type manifold (45 type).

4
ATEX Compliant
Body Ported Type Series 52-SY5000

Dimensions

2-position single
L plug connector (L)
52-SY5120-L-01 (-F2) In case with foot bracket
22.6 21 52-SY5120-L-01-F1
47

16.7
38 4.5

16.6
22
29
2 x M3 x 0.5 Threads depth 3.5
(For bracket mounting)
65 2 x ø3.2
14.7
Insulation: Black (–) (Mounting holes)

11.6
40
B
A
Insulation: Red (+)
Manual override 2 x ø3.2
16.2 (Mounting holes for manifold)
36 2 x 1/8"
(2 x ø3.2 Mounting holes) (37) A (4), B (2) port
44 (For E type)

0.3 mm2
(40.2)
(36.7)
40

32.5
20.5
14.7

ø1.55

111.8
(1.2) (32.3)
(11.7) L 109.1
(Lead wire length)
3 x 1/8" 32.3
0.8

{P (1), EA (5), EB (3) port}


1.6

1.2
15
(20)

EA P EB
32.5 10.5
2 x ø2.2
(Positioning for manifold gasket) 27.2
(45)

L plug connector with cover (LL)


52-SY5120-LL-01 (-F2)

Insulation: Red (+)


Insulation: Black (–)
ø4.1

0.3 mm2
14.7

L 104
(Lead wire length)

Cable type (TT)


52-SY5120-TT-01 (-F2)
Lead wire marking
No.1 (+), No.2 (–)
ø5.9

12

0.75 mm2

L 120.8
(Lead wire length)
Max.10

5
ATEX Compliant
Body Ported Type Series 52-SY5000

Dimensions
2-position double
22.6
L plug connector (L)
52-SY5220-L-01 (-F2)

16.7
2 x M3 x 0.5 Threads depth 3.5
(For bracket mounting)
65.4

11.6
Insulation: Black (–)
B

Insulation: Red (+) A


Manual override 2 x ø3.2
16.2 (Mounting holes for manifold)
36 2 x 1/8"
{A (4), B (2) port}
37 (2 x ø3.2 Mounting holes)
44 (For E type)

0.3 mm2

(36.7)
40

32.5
(40.2)

20.5
14.7

ø1.55

(1.2) L 153.6
(11.7) (Lead wire length)
3 x 1/8" (76.8)
{P (1), EA (5), EB (3) port}

0.8
1.6

(20)
15

EA P EB

2 x ø2.2 27.2
(Positioning for manifold gasket)
(45)

L plug connector with cover (LL)


52-SY5220-LL-01 (-F2)
L 143.4
(Lead wire length)

Insulation: Red (+)


Insulation: Black (–)
ø4.1

14.7

0.3 mm2

(71.7)

Cable type (TT)


52-SY5220-TT-01 (-F2)
Max.10
L 177
(Lead wire length)

Lead wire marking


No.1 (+), No.2 (–)
ø5.9

12

0.75 mm2

(88.5)

6
ATEX Compliant
Body Ported Type Series 52-SY5000

Dimensions
3-position closed centre/
22.6
exhaust centre/pressure centre
L plug connector (L)

16.7
3
52-SY5420-L-01 (-F2)
5
2 x M3 x 0.5 Threads depth 3.5
(For bracket mounting) (89.4)
32.7 45.3

11.6
Insulation: Black (–)

B
A
Insulation: Red (+)
2 x ø3.2
16.2
Manual override (Mounting holes for manifold)
36 2 x 1/8"
{A (4), B (2) port}
(37)
44 (For E type) (2 x ø3.2 Mounting holes)

0.3 mm2

(36.7)
40

32.5
(40.2)

20.5
14.7

ø1.55

(1.2) L 166.2
(Lead wire length)
3 x 1/8" 89.4
{P (1), EA (5), EB (3) port} 0.8
1.6

(20)
15

EA P EB

2 x ø2.2 27.2
(Positioning for manifold gasket)
(45)

L plug connector with cover (LL)


3
52-SY5420-LL-01 (-F2)
5 L 156
(Lead wire length)

Insulation: Red (+)


Insulation: Black (–)
ø4.1

14.7

0.3 mm2

84.3

Cable type (TT)


3
52-SY5420-TT-01 (-F2)
5 Max.10
L 189.6
(Lead wire length)

Lead wire marking


No.1 (+), No.2 (–)
ø5.9

12

0.75 mm2

101.1
7
ATEX Compliant
Body Ported Type Series 52-SY7000

Dimensions
2-position single
In case with foot bracket
L plug connector (L)
52-SY7120-L-02-(F1)
52-SY7120-L-02 (-F2)

2 x M4 x 0.7 Threads depth 6.5 20 29.4


(For bracket mounting)
57

7
46 5.5

19.8
28
38
79.2
Insulation: Black (–) Manual override
B 14.7

13.6
40
A
Insulation: Red (+)
2 x ø4.2
20 (Mounting holes for manifold)
42 2 x 1/4"
(14) {A (4), B (2) port}
1.2 (52)
(2 x ø4.2 Mounting holes)
44 (For E type)

(49.5)

0.3 mm2
(42.5)
40

40
24.5
14.7

125
(39.4)
L 123.3
(Lead wire length) 1/4"
{P (1) port} 39.4
0.9

2 x 1/8"
2

{EA (5), EB (3) port}

1.2
(23.9)
18

EA P EB
39.5 13
2 x ø2.2 36
(Positioning for manifold gasket) (66)

L plug connector with cover (LL)


52-SY7120-LL-02 (-F2)

Insulation: Red (+)


Insulation: Black (–)
ø4.1

14.7

0.3 mm2

L 118.2
(Lead wire length)

Cable type (TT)


52-SY7120-TT-02 (-F2)
Lead wire marking
No.1 (+), No.2 (–)
ø5.9

0.75 mm2
12

L 135
(Lead wire length)
Max.10
8
ATEX Compliant
Body Ported Type Series 52-SY7000

Dimensions
2-position double
L plug connector (L) 20 2 x M4 x 0.7 Threads depth 6.5
(For bracket mounting)
52-SY7220-L-02 (-F2)

7
79.6
Insulation: Black (–)
B

13.6
Insulation: Red (+) A
Manual override 2 x ø4.2
20 (Mounting holes for manifold)
42 2 x 1/4"
(52) {A (4), B (2) port}

(2 x ø4.2 Mounting holes)


44 (For E type)

0.3 mm2

(42.5)
(49.5)
40

40
24.5
14.7

ø1.55

(1.2) L 167.8
(14) (Lead wire length)
1/4"
(83.9)
{P (1) port}
2 x 1/8" 0.9
{EA (5), EB (3) port}
2

18

EA P EB
(23.9)

36
2 x ø2.2
(Positioning for manifold gasket) (66)

L plug connector with cover (LL)


52-SY7220-LL-02 (-F2)
L 157.6
(Lead wire length)

Insulation: Red (+)


Insulation: Black (–)
ø4.1

14.7

0.3 mm2

(78.8)

Cable type (TT)


52-SY7220-TT-02 (-F2)
Max.10
L 191.2
(Lead wire length)

Lead wire marking


No.1 (+), No.2 (–)
ø5.9

0.75 mm2
12

(95.6)

9
ATEX Compliant
Body Ported Type Series 52-SY7000

Dimensions
3-position closed centre/exhaust centre/pressure centre 20 2 x M4 x 0.7 Threads depth 6.5
L plug connector (L) (For bracket mounting)
3

7
52-SY7420-L-02 (-F2)
5

39.8 52.8
Insulation: Black (–)
B

13.6
Insulation: Red (+) A
Manual override 2 x ø4.2
20 (Mounting holes for manifold)
42 2 x 1/4"
(52) {A (4), B (2) port}
(2 x ø4.2 Mounting holes)

44 (For E type)
0.3 mm2

(42.5)
(49.5)
40

40
24.5
14.7

ø1.55

(1.2) L 180.8
(14) (Lead wire length)
1/4"
96.9
{P (1) port}
2 x 1/8"

0.9
{EA (5), EB (3) port}
2

18
EA P EB
(23.9)
36
2 x ø2.2
(Positioning for manifold gasket) (66)

L plug connector with cover (LL)


3
52-SY7420-LL-02 (-F2)
5 L 170.6
(Lead wire length)

Insulation: Red (+)


Insulation: Black (–)
ø4.1

14.7

0.3 mm2

91.8

Cable type (TT)


3
52-SY7420-TT-02 (-F2)
5 Max.10
L 204.2
(Lead wire length)

Lead wire marking


No.1 (+), No.2 (–)
ø5.9

0.75 mm2
12

108.6
10
ATEX Compliant
Body Ported Type Series 52-SY9000

Dimensions
2-position single
L plug connector (L) 109.3

52-SY9120-L- 02 03
 Insulation: Black (–)
6.5 (56.3)

4A 2B

18.4
Insulation: Red (+) Manual override
33.6 3 x ø3.2
64.2 (Mounting holes for manifold)

2 x 1/4", 3/8"
{4 (A), 2 (B) port}

46 (For E type)
0.3 mm2

51.5
42

36.6
16.7

ø1.55

10
2 x ø4.4
(12) 24.9 43.85
(Mounting holes)
L 153.4
(Lead wire length)

3 x 1/4" 56.3
{1 (P), 3 (EB), 5 (EA) port}

0.5
23
5EA 1P 3EB

0.5
49.8

L plug connector with cover (LL)


52-SY9120-LL- 02
03 

Insulation: Red (+)


ø4.1

Insulation: Black (–)


16.7

0.3 mm2

L 148.3
(Lead wire length)

Cable type (TT)


52-SY9120-TT-02
03 

Lead wire marking


No.1 (+), No.2 (–)
14

0.75 mm 2
L 165.1
(Lead wire length) Max.10

11
ATEX Compliant
Body Ported Type Series 52-SY9000

Dimensions
2-position double
L plug connector (L) 106
52-SY9220-L- 02
03  6.5
Insulation: Black (–)

18.4
4A 2B

Insulation: Red (+) Manual override


33.6 3 x ø3.2
64.2 (Mounting holes for manifold)
2 x 1/4", 3/8"
{4 (A), 2 (B) port}

46 (For E type)
0.3 mm2

51.5
42

36.6
16.7

ø1.55

10
2 x ø4.4
(12) 24.9
(Mounting holes)
L 194.2
(Lead wire length)
97.1
3 x 1/4"
{1 (P), 3 (EB), 5 (EA) port}

0.5
23
5EA 1P 3EB

0.5
49.8

L plug connector with cover (LL)


52-SY9220-LL- 02
03 

Insulation: Red (+)


ø4.1

Insulation: Black (–)


16.7

0.3 mm2

L 184
(Lead wire length)

Cable type (TT)


52-SY9220-TT-02
03 

Lead wire marking


No.1 (+), No.2 (–)
14

0.75 mm2
L 217.6
(Lead wire length)
Max.10

12
ATEX Compliant
Body Ported Type Series 52-SY9000

Dimensions
3-position closed centre/exhaust centre/pressure centre
L plug connector (L) 123
3 02 6.5
52-SY9420-L- 03  Insulation
5 Black (–)
4A 2B

18.4
Insulation Manual override
Red (+) 33.6 3 x ø3.2
64.2 (Mounting holes for manifold)
2 x 1/4", 3/8"
{4 (A), 2 (B) port}

46 (For E type)
0.3 mm2

51.5
42

36.6
16.7

ø1.55

10
2 x ø4.4
(12) 24.9
(Mounting holes)
L 210.7
(Lead wire length)

113.6
3 x 1/4"
{1 (P), 3 (EB), 5 (EA) port}

0.5
23
5EA 1P 3EB
0.5

49.8

L plug connector with cover (LL)


3
52-SY9420-LL- 02
03 
(108.5)

Insulation: Red (+)


ø4.1

Insulation: Black (–)


16.7

0.3 mm2

L 201
(Lead wire length)

Cable type (TT)


3
52-SY9420-TT-02
03 
(125.3)

Lead wire marking


No.1 (+), No.2 (–)
14

0.75 mm2
L 234.1
(Lead wire length) Max.10

13
ATEX Compliant
Base Mounted Type Series 52-SY5000

Dimensions
2-position single
L plug connector (L)
52-SY5140 (R) -L-02
18 19

9.5
37.2 2 x ø4.3 60.3
(Mounting holes)
15.5 48 8.3 M5 x 0.8 15.5
Manual override
(External pilot port)

4
Insulation
A B
17.5

Black (–)
A B

35
Insulation X
PE

EA P EB
Red (+)
17 56 4.3 17
M5 x 0.8 65 62.5
(Pilot EXH. port)
<For external pilot type> 109.1
66.5 (For E type)

L
(Lead wire length)

0.3 mm2
ø1.55

22
9.5

18 18
5 x 1/4"
28 (Piping ports)

L plug connector with cover (LL)


52-SY5140 (R) -LL-02
L 104
(Lead wire length)
Insulation: Red (+)
Insulation: Black (–)

0.3 mm2
ø4.1

37.2

Cable type (TT)


52-SY5140 (R) -TT-02 Max.10
L 120.8
(Lead wire length)
Lead wire marking
No.1 (+), No.2 (–)

0.75 mm2
ø5.9

34.5

14
ATEX Compliant
Base Mounted Type Series 52-SY5000

Dimensions
2-position double 18 19

L plug connector (L)

9.5
52-SY5240 (R) -L-02

37.2 2 x ø4.3
(Mounting holes)
15.5 48 4 M5 x 0.8 15.5
Manual override (External pilot port)

4
Insulation: Black (–)
A B
17.5

17.5
A
B
PE Insulation: Red (+) X
EA P EB

35
17
56 17

M5 x 0.8 65.4 62.5


(Pilot EXH. port) 153.6
<For external pilot type>

L
66.5 (For E type)

(Lead wire length)


ø1.55

0.3 mm2 22

18 18
9.5

28
5 x 1/4"
(Piping ports)

L plug connector with cover (LL)


52-SY5240 (R) -LL-02

L 143.4
Insulation: Red (+) (Lead wire length)
Insulation: Black (–)

0.3 mm2
ø4.1

37.2

(71.7)

Cable type (TT)


52-SY5240 (R) -TT-02
Max.10
L 177
(Lead wire length)
Lead wire marking
No.1 (+), No.2 (–)

0.75 mm2
ø5.9

34.5

(88.5)

15
ATEX Compliant
Base Mounted Type Series 52-SY5000

Dimensions
3-position closed centre/exhaust centre/pressure centre
L plug connector (L)
3 18 19

52-SY5440 (R) -L-02

9.5
5

37.2 2 x ø4.3
(Mounting holes)
15.5 48 4 M5 x 0.8 15.5
Manual override (External pilot port)
Insulation: Black (–)

4
A B
17.5

17.5
A
B
X
PE

Insulation: Red (+) EA P EB

35
17
56 17
M5 x 0.8
78 44.1 62.5
(Pilot EXH. port)
<For external pilot type> 166.2

L
66.5 (For E type)

(Lead wire length)

0.3 mm2
ø1.55

22

18 18
9.5

5 x 1/4" 28
(Piping ports) 89.4

L plug connector with cover (LL)


3
52-SY5440 (R) -LL-02
5 L 156
Insulation: Red (+) (Lead wire length)
Insulation: Black (–)

0.3 mm2
ø4.1

37.2

84.3

Cable type (TT)


3
52-SY5440 (R) -TT-02 Max.10
5 L 189.6
(Lead wire length)
Lead wire marking
No.1 (+), No.2 (–)

0.75 mm2
ø5.9

34.5

101.1

16
ATEX Compliant
Base Mounted Type Series 52-SY7000

Dimensions
21 22.5
2-position single
L plug connector (L)

13.5
52-SY7140 (R) -L- 02
03 

79.2
41.7
61 10.4
21.5 2 x ø4.3 21
(Mounting holes)
Manual override M5 x 0.8

4
A B (External pilot port)
Insulation: Black (–)
23

PE A

38
46
B
Insulation: Red (+)

X
EA P EB

21 69 6.4 21.5
123.3 67.2
M5 x 0.8
(Pilot EXH. port)
<For external pilot type>
71.2 (For E type)

L
(Lead wire length)
ø1.55

0.3 mm2
26.5
11.5
13.5

5 x 3/8", 1/4" 20.5 20.5


(Piping ports) 33

L plug connector with cover (LL)


52-SY7140 (R) -LL- 02
03  L 118.2
(Lead wire length)
Insulation: Red (+)
Insulation: Black (–)

0.3 mm2
ø4.1

41.7

Cable type (TT)


52-SY7140 (R) -TT- 02
03  L
Max.10
135
(Lead wire length)
Lead wire marking
No.1 (+), No.2 (–)

0.75 mm2
ø5.9

39

17
ATEX Compliant
Base Mounted Type Series 52-SY7000

Dimensions
2-position double
L plug connector (L) 21 22.5
52-SY7240 (R) -L- 02
03 

13.5
41.7 61 4
2 x ø4.3
21.5 (Mounting holes) 21
Manual override M5 x 0.8

4
Insulation: Black (–) (External pilot port)
A B
23

23
PE

38
46
B

X
Insulation: Red (+) EA P EB

21 69 21.5
M5 x 0.8 79.6 67.2
(Pilot EXH. port)
<For external pilot type> 167.8

L
71.2 (For E type)

(Lead wire length)


ø1.55

0.3 mm2
26.5
13.5
11.5

5 x 3/8", 1/4" 20.5 20.5


(Piping ports) 33

L plug connector with cover (LL)


52-SY7240 (R) -LL- 02
03  L 157.6
(Lead wire length)
Insulation: Red (+)
Insulation: Black (–)

0.3 mm2
ø4.1

41.7

(78.8)

Cable type (TT)


52-SY7240 (R) -TT- 02
03  Max.10
L 191.2
(Lead wire length)
Lead wire marking
No.1 (+), No.2 (–)
ø5.9

0.75 mm2
39

(95.6)

18
ATEX Compliant
Base Mounted Type Series 52-SY7000

Dimensions
3-position closed centre/exhaust centre/pressure centre
L plug connector (L) 21 22.5

13.5
3
52-SY7440 (R) -L- 02
03 
5

41.7 61 4
2 x ø4.3
21.5 (Mounting holes) 21
Manual override M5 x 0.8

4
Insulation (External pilot port)
A B
Black (–)
23

23
PE

38
B

X
Insulation

46
EA P EB
Red (+)
21 69 21.5
M5 x 0.8 92.6 44.1 67.2
(Pilot EXH. port)
<For external pilot type> 180.8

L
71.2 (For E type)

(Lead wire length)


ø1.55

0.3 mm2
26.5
13.5
11.5

5 x 3/8", 1/4" 20.5 20.5


(Piping ports) 33
96.9

L plug connector with cover (LL)


3
52-SY7440 (R) -LL- 02
03 
5
L 170.6
(Lead wire length)
Insulation: Red (+)
Insulation: Black (–)

0.3 mm2
ø4.1

41.7

91.8

Cable type (TT)


3
52-SY7440 (R) -TT- 02
03 
Max.10
5 L
(Lead wire length)
204.2

Lead wire marking


No.1 (+), No.2 (–)
ø5.9

0.75 mm2
39

108.6
19
ATEX Compliant
Base Mounted Type Series 52-SY9000

Dimensions
2-position single 29 30

L plug connector

17.5
52-SY9140 (R) -L- 03
04 

109.3
51.2 86.5 16.8
25 2 x ø5.4
27
Manual override (Mounting holes) 1/8"

5
(External pilot port)
Insulation A4 B2
28.5

PE Black (−)
B

47
57
A
Insulation X
Red (+) 5EA 1P 3EB

27 96.5 11.8 25
1/8" 153.4 76.5
(Pilot EXH. port)
<For external pilot type>
L
(Lead wire length)
ø1.55

0.3 mm2
80.5 (For E type)

34
17.5
15.5

29.5 29.5
5 x 3/8", 1/2" (Piping ports)
44.5

L plug connector with cover (LL)


52-SY9140 (R) -LL- 03
04 
L 148.3
(Lead wire length)
Insulation: Red
Insulation: Black

0.3 mm2
ø4.1

51.2

Cable type (TT)


52-SY9140 (R) -TT- 03
04  Max.10
L 165.1
(Lead wire length)
Lead wire marking
No.1 (+), No.2 (−)

0.75 mm2
ø5.9

48.5

20
ATEX Compliant
Base Mounted Type Series 52-SY9000

Dimensions
29 30
2-position double
L plug connector (L)

17.5
52-SY9240 (R) -L- 03
04 

106
51.2 86.5
25 2 x ø5.4
27
Manual override (Mounting holes) 1/8"

5
(External pilot port)
Insulation 4A 2B
28.5

PE Black (−)

47
57
A B
Insulation X
Red (+) 5EA 1P 3EB

27 96.5 25
1/8" 194.2 76.5
(Pilot EXH. port)
<For external pilot type>
L
(Lead wire length)
ø1.55

0.3 mm2
80.5 (For E type)

34
17.5
15.5

29.5 29.5
5 x 3/8", 1/2"
44.5
(Piping ports)

L plug connector with cover (LL)


52-SY9240 (R) -LL- 03
04  L 184
(Lead wire length)
Insulation: Red (+)
Insulation: Black (−)

0.3 mm2
ø4.1

51.2

(92)

Cable type (TT)


52-SY9240 (R) -TT- 03
04  L
Max.10
217.6
(Lead wire length)
Lead wire marking
No.1 (+), No.2 (−)

0.75 mm2
ø5.9

48.5

(108.8)
21
ATEX Compliant
Base Mounted Type Series 52-SY9000

Dimensions
29 30
3-position closed centre/exhaust centre/
pressure centre

17.5
L plug connector (L)
3
52-SY9440 (R) -L- 03
04 
5

123
51.2 86.5
25 2 x ø5.4
27
Manual override (Mounting holes) 1/8"

5
(External pilot port)
Insulation A4 B2
28.5

PE Black (−)
A B

47

57
Insulation X
Red (+) 5EA 1P 3EB

27 96.5 69.1 25
1/8" 210.7 76.5
(Pilot EXH. port)
<For external pilot type> L
(Lead wire length)
ø1.55

0.3 mm2
80.5 (For E type)

34
17.5
15.5

29.5 29.5
5 x 3/8", 1/2"
44.5
(Piping ports)
113.6

L plug connector with cover (LL)


3
52-SY9440 (R) -LL- 03
04  L 200
5 (Lead wire length)
Insulation: Red (+)
Insulation: Black (−)

0.3 mm2
ø4.1

51.2

108

Cable type (TT)


3 Max.10
52-SY9440 (R) -TT- 03 04  L 234.1
5 Lead wire marking
(Lead wire length)

No.1 (+), No.2 (−)

0.75 mm2
ø5.9

48.5

125.3

22
ATEX Compliant
5 Port Solenoid Valve

Series 56-VQC1000 Manifold with M- or T- kit


II 3G Ex nA II B T5 Gc X
II 3D Ex tc III C T85°C Dc X IP67
–10°C ≤ Ta ≤ +50°C
Special condition X "Protect from Impact"

How to Order Manifold Note) Refer to Serial transmission system on page 30 for the S kit.

56 VV5QC 1 1 08 C3 TD0 N ...... M


F / T / S Kit
ATEX category 3

Series 56-VQC1000
Option
Nil None
Base mounted plug-in B All stations with back pressure check valve
D With DIN rail (Rail length: Standard)
D With DIN rail (Rail length: Special)
Stations K Special wiring specifications (Except double wiring)
01 1 station N With name plate
… … R External pilot

The minimum or maximum number of stations differs


depending on the electrical entry. (Refer to “Electrical
Entry/Cable Length”)
Cylinder port size COM
C3 With ø3.2 One-touch fitting N −COM.
C4 With ø4 One-touch fitting
C6 With ø6 One-touch fitting
M5 M5 thread
CM Mixed sizes and with port plug
L3 Top ported elbow, with ø3.2 One-touch fitting
L4 Top ported elbow, with ø4 One-touch fitting
L6 Top ported elbow, with ø6 One-touch fitting
L5 M5 thread
LM Elbow port, mixture sizes
B3 Bottom ported elbow, with ø3.2 One-touch fitting
B4 Bottom ported elbow, with ø4 One-touch fitting
B6 Bottom ported elbow, with ø6 One-touch fitting
B5 M5 thread
BM Elbow for bottom port, mixture sizes

Kit designation/Electrical entry/Cable length

M Kit
(Circular connector kit) T Kit
(Terminal block box kit) S Kit
(Serial transmission kit: EX500 gateway type)

26 pins SI unit: 56-EX500


Note) A separate gateway unit and communication cable are
MD0 Circular connector kit (26P) without cable 1 to 12 required.
MD1 Circular connector kit (26P) with 1.5 m cable stations 1 to 10 stations 1 to 8 stations
MD2 Circular connector kit (26P) with 3 m cable (Up to 24 TD0 Terminal block box kit (Up to 20 SDA2 DeviceNet, PROFIBUS DP (Up to 16
MD3 Circular connector kit (26P) with 5 m cable solenoid coils) solenoid coils) solenoid coils)
∗ The maximum number of stations displayed in parentheses is applied to the special wiring specifications. (Option “-K”) Contact SMC for 56-EX250 with Profibus DP
The maximum number of stations is determined by the total number of solenoids. (Single solenoid type: 1 point, Double solenoid type: 2 points)
Make sure that the total number of solenoids does not exceed the maximum number of stations. Additionally, when combining with option
parts, make sure that the maximum number of stations is not exceeded.

All other specifications are the same as the standard products Series VQC.
For details, refer to the WEB catalog or Best Pneumatics No. 1.

23
Series 56-VQC1000
ATEX Compliant
Base-Mounted Type/Plug-in Unit

How to Order Valves

56 VQC 1 1 0 0 5
ATEX category 3
Manual override
Series 56-VQC1000 Nil: Non-locking push type
(Tool required)
Type of actuation
1 2-position single
2-position double (Metal)
2
2-position double (Rubber)
3 3-position closed centre
4 3-position exhaust centre
B: Locking type
5 3-position pressure centre
(Tool required)
A Note) 4-position dual 3 port valve (A)
BNote) 4-position dual 3 port valve (B)
CNote) 4-position dual 3 port valve (C)
Note) For rubber seal type only.

C: Locking type (Manual)


Manifold Option

Ground terminal 56-VQC1000


Blanking plate assembly VVQ1000-10A-1
Individual SUP spacer VVQ1000-P-1-C6
Individual EXH spacer VVQ1000-R-1-C6
SUP block plate VVQ1000-16A D: Slide locking type
(Manual)
EXH block plate —
EXH block base assembly VVQC1000-19A--
Back pressure check valve assembly [-B] VVQ1000-18A
Port plug VVQ0000-58A
2 stations matching fitting assembly VVQ1000-52A-C8
Elbow fitting assembly VVQ1000-F-L-
Port plug VVQ0000-58A
Blanking plug KQ2P-
DIN rail mounting bracket [-D] VVQ1000-57A(-S)
Name plate [-N] VVQ1000-N-
Note) Please refer to standard catalogues for details.
Do not use options other than specified in this table. Coil voltage
Only these standard parts without "56-" prefix can be used. 5 24 VDC

Function
Nil Standard type (1W)
R Note) External pilot
Note) Not available for dual 3 port.

Seal type
0 Metal seal
1 Rubber seal

Note) ''56-'' solenoid valve should be installed in ''56-VV5QC11'' manifold.


Power consumption when starting is 1W, when maintaining 0.35W.
''56-VQC'' solenoid valve has no polarity"

24
ATEX Compliant
5 Port Solenoid Valve

Series 56-VQC2000 Manifold with M- or T- kit


II 3G Ex nA II B T5 Gc X
II 3D Ex tc III C T85°C Dc X IP67
–10°C ≤ Ta ≤ +50°C
Special condition X "Protect from Impact"

How to Order Manifolds Note) Refer to Serial transmission system on page 30 for the S kit.

56 VV5QC 2 1 08 C4 TD0 N ...... M


F / T / S Kit
ATEX category 3

Series 56-VQC2000
Options
Nil None
B All stations with back pressure check valve
Base-Mounted Plug-in D With DIN rail (rail length: standard)
D With DIN rail (rail length: special)
K Special wiring specifications (except for double wiring)
Stations N With name plate
01 1 station R External pilot
… … T Branched P and R ports on U side

The minimum or maximum number of stations differs


depending on the electrical entry (refer to “Electrical
entry/Cable length”).

Cylinder port size


C4 With ø4 One-touch fitting COM.
C6 With ø6 One-touch fitting N −COM.
C8 With ø8 One-touch fitting
CM Mixed sizes and with port plug
L4 Top ported elbow With ø4 One-touch fitting
L6 Top ported elbow With ø6 One-touch fitting
L8 Top ported elbow With ø8 One-touch fitting
LM Elbow port, mixture sizes
B4 Bottom ported elbow With ø4 One-touch fitting
B6 Bottom ported elbow With ø6 One-touch fitting
B8 Bottom ported elbow With ø8 One-touch fitting
BM Elbow for bottom port, mixture sizes

Kit designation/Electrical entry/Cable length

M Kit
(Multiple connector kit) T Kit
(Terminal block box kit) S Kit
(Serial transmission kit: EX500 gateway type)

26 pins SI unit: 56-EX500


Note) A separate gateway unit and communication cable are
MD0 Multiple connector kit (26P) without cable 1 to 12 required.
MD1 Multiple connector kit (26P) with 1.5 m cable stations 1 to 10 stations 1 to 8 stations
MD2 Multiple connector kit (26P) with 3 m cable (Up to 24 TD0 Terminal block box kit (Up to 20 SDA2 DeviceNet, PROFIBUS DP (Up to 16
MD3 Multiple connector kit (26P) with 5 m cable solenoid coils) solenoid coils) solenoid coils)
∗ The maximum number of stations displayed in parentheses is applied to the special wiring specifications. (Option “-K”) Contact SMC for 56-EX250 with Profibus DP.
The maximum number of stations is determined by the total number of solenoids. (Single solenoid type: 1 point, Double solenoid type: 2 points)
Make sure that the total number of solenoids does not exceed the maximum number of stations. Additionally, when combining with option
parts, make sure that the maximum number of stations is not exceeded.

All other specifications are the same as the standard products Series VQC.
For details, refer to the WEB catalog or Best Pneumatics No. 1.

25
Series 56-VQC2000
ATEX Compliant
Base-Mounted Type/Plug-in Unit

How to Order Valves

56 VQC 2 1 0 0 5
ATEX category 3
Manual override
Series 56-VQC2000 Nil: Non-locking
push type (Tool required)
ø4.2
Type of actuation
1 2-position single
2-position double (Metal)
2
2-position double (Rubber)
3 3-position closed centre
4 3-position exhaust centre B: Locking type
5 3-position pressure centre (Tool required)
ø4.2
ANote) 4-position dual 3-port valve (A)
BNote) 4-position dual 3-port valve (B)
CNote) 4-position dual 3-port valve (C)
Note) For rubber seal type only.

C: Locking type
(Manual)
Manifold Options 11 mm

Name 56-VQC2000
Blanking plate assembly VVQ2000-10A-1
Individual SUP spacer VVQ2000-P-1-C8 D: Slide
Individual EXH spacer VVQ2000-R-1-C8 locking type (Manual)
ø2
SUP block plate VVQ2000-16A
OFF
EXH block plate VVQ2000-19A ON
EXH block base assembly —
Back pressure check valve assembly [-B] VVQ2000-18A
Port plug VVQ1000-58A
Dual flow fitting assembly VVQ2000-52A-C10
Elbow fitting assembly VVQ2000-F-L-
Coil voltage
Port plug VVQ1000-58A
5 24 VDC
Blanking plug KQ2P-
DIN rail mounting bracket [-D] VVQ2000-57A (-S)
Function
Name plate [-N] VVQ2000-N-
Nil Standard type (1W)
Notes) : Please refer to standard catalogues for details.
R Note) External pilot
Do not use options other than specified in this table.
Only these standard parts without "56-" prefix can be used. Note) Not available for dual 3 port.

Seal type
0 Metal seal
1 Rubber seal

Note) ''56-'' solenoid valve should be installed in ''56-VV5QC21'' manifold.


Power consumption when starting is 1 W, when maintaining 0.35 W.
"56-VQC" solenoid valve has no polarity.

26
ATEX Compliant
5 Port Solenoid Valve

Series 56-VQC4000 Manifold with M- or T- kit


II 3G Ex nA II B T5 Gc X
II 3D Ex tc III C T85°C Dc X IP67
–10°C ≤ Ta ≤ +50°C
Special condition X "Protect from Impact"

How to Order Manifolds Note) Refer to Serial transmission system on page 30 for the S kit.

56 VV5QC 4 1 08 02 TD0 N ⋅⋅⋅⋅⋅⋅ M


F / T / S Kit
ATEX category 3

Series 56-VQC4000
Options
Nil None
Base-Mounted Plug-in Special wiring specifications
K
(except for double wiring)
N With name plate (T kit only)

Stations
01 1 station

The maximum number of stations differs depending on


the electrical entry (refer to “Electrical entry/Cable length”).
COM.
N –COM.
Cylinder port size
C8 With ø8 One-touch fitting
C10 With ø10 One-touch fitting
C12 With ø12 One-touch fitting
CM Mixed sizes
02 1/4 thread
03 3/8 thread
B Bottom port 1/4

Thread type
Nil Rc
F G
N NPT
T NPTF
Kit designation/Electrical entry/Cable length

M Kit
(Multiple connector kit) T Kit
(Terminal block box kit) S Kit
(Serial transmission kit: EX500 gateway type)

26 pins SI unit: 56-EX500


Note) A separate gateway unit and communication cable are
MD0 Multiple connector kit (26P) without cable required.
1 to 12
MD1 Multiple connector kit (26P) with 1.5 m cable stations 1 to 10 stations 1 to 8 stations
MD2 Multiple connector kit (26P) with 3 m cable (Up to 24 TD0 Terminal block box kit (Up to 20 SDA2 DeviceNet, PROFIBUS DP (Up to 16
MD3 Multiple connector kit (26P) with 5 m cable solenoid coils) solenoid coils) solenoid coils)
∗ The maximum number of stations displayed in parentheses is applied to the special wiring specifications. (Option “-K”) Contact SMC for 56-EX250 with Profibus DP.
The maximum number of stations is determined by the total number of solenoids. (Single solenoid type: 1 point, Double solenoid type: 2 points)
Make sure that the total number of solenoids does not exceed the maximum number of stations. Additionally, when combining with option
parts, make sure that the maximum number of stations is not exceeded.

All other specifications are the same as the standard products Series VQC.
For details, refer to the WEB catalog or Best Pneumatics No. 1.

27
Series 56-VQC4000
ATEX Compliant
Base-Mounted Type/Plug-in Unit

How to Order Valves

56 - VQC 4 1 0 0 5
Manual override
ATEX category 3 Nil: Non-locking
push type (Tool required)

Series 56-VQC4000

Type of actuation
1 2-position single
2-position double (Metal)
2
2-position double (Rubber)
3 3-position closed centre B: Locking type
4 3-position exhaust centre (Tool required)
5 3-position pressure centre
6 3-position perfect

Manifold Options

Name 56-VQC4000
Blanking plate assembly VVQ4000-10A-1
Individual SUP spacer VVQ4000-P-1-
Individual EXH spacer VVQ4000-R-1-
Coil voltage
SUP block plate VVQ4000-16A
5 24 VDC
EXH block plate VVQ4000-16A
EXH block base assembly —
Back pressure check valve assembly [-B] —
Port plug —
Function
Nil Standard type (1W)
Dual flow fitting assembly —
R Note) External pilot
Elbow fitting assembly —
Note) Not available for dual 3 port.
Port plug —
Blanking plug KQ2P- Seal type
DIN rail mounting bracket [-D] — 0 Metal seal
Name plate [-N] — 1 Rubber seal
Notes) : Please refer to standard catalogues for details.
Do not use options other than specified in this table.
Only these standard parts without "56-" prefix can be used.
Note) ''56-'' solenoid valve should be installed in ''56-VV5QC41'' manifold.
Power consumption when starting is 1 W, when maintaining 0.35 W.
"56-VQC" solenoid valve has no polarity.

28
ATEX Compliant
For Input/Output

Series 56-EX250
How to Order SI Units

Input block
56 EX250 S PR1 X42
SI unit
Communication Protocol
PR1 PROFIBUS DP
ATEX category 3

SI Unit Specifications

Model 56-EX250-SPR1-X42
Protocol PROFIBUS DP-V0
Communication speed (9.6/19.2/45.45/93.75/187.5/500 kbps), (1.5/3/6/12 Mbps)
Number of outputs Max. 32 points
Output type Source/PNP (Negative common)
Output Solenoid valve with protection circuit for 24 VDC and 1.5 W
II 3G Ex nA II T4 X 5°C ≤ Ta ≤ 45°C Connected load
specifications or less surge voltage (made by SMC)
II 3D Ex tD A22 IP67 T66°C X
Power supply 24 VDC + 10%/−5%
Current supply Max. 2.0 A
Number of inputs Max. 32 points
Input Input block 56-EX250-IE2-X43
specifications Power supply 24 VDC ± 20%
Current supply Max. 1.0 A
Internal current consumption (Unit) 100 mA or less
Operating temperature/humidity range +5 to +45°C at 35% to 85% RH (without condensation)
Withstand voltage 500 VAC for 1 min. between external terminal and FG
Insulation resistance 10 MΩ or more (500 VDC) between external terminal and FG
Enclosure IP67
Weight 250 g

How to Order Input Block

56 EX250 IE 2 X43
Block type
2 M12 connector, 4 inputs
ATEX category 3
Input Block Specifications

Model 56-EX250-IE2-X43
II 3G Ex nA II T4 X 5°C ≤ Ta ≤ 45°C Source type (PNP output)
II 3D Ex tD A22 IP67 T77°C X Applicable sensor
Sink type (NPN output)/(selected using a switch)
Number of inputs 4 inputs
Rated voltage 24 VDC
Rated input current Approx. 8 mA
Green LED is ON (when SI unit power supply is ON).
Display
Yellow LED is ON (when input signal is ON).
Connector on the input device side M12 connector (4 pins, plug or 5 pins, plug)
Sensor supply current Max. 30 mA/Sensor
Operating temperature/humidity range −10 to +50°C at 35% to 85% RH (without condensation)
Withstand voltage 500 VAC for 1 min. between external terminal and FG
Insulation resistance 10 MΩ or more (500 VDC) between external terminal and FG
Enclosure IP67
Weight 90 g

All other specifications are the same as the standard products Series EX250.
For details, refer to the WEB catalog or Best Pneumatics No. 1.

29
ATEX Compliant
Decentralized Serial Wiring (GW System, 4 Branches)

Series 56-EX500
How to Order

Gateway (GW) Unit

56 EX500 G PR1A
Communication Protocol
PR1A PROFIBUS DP
ATEX category 3 DN1-X8 DeviceNetTM

II 3G Ex nA II T4 X 5°C�≤�Ta�≤�45°C
II 3D Ex tD A22 IP65 T57°C X (56-EX500-GPR1A)

II 3G Ex nA II T4 X 5°C�≤�Ta�≤�45°C
II 3D Ex tD A22 IP65 T53°C X (56-EX500-GDN1-X8)

Gateway (GW) Unit Specifications

Model 56-EX500-GDN1-X8 56-EX500-GPR1A


Applicable PLC/Communication protocol DeviceNetTM PROFIBUS DP-V0
Communication speed 125/250/500 Kbps (9.6/19.2/45.45/93.75/187.5/500 Kbps),(1.5/3/6/12 Mbps)
Rated voltage 24 VDC
Input and control unit power supply: 24 VDC ±10%
Power supply voltage range
Solenoid valve power supply: 24 VDC +10%/−5%
Current consumption 200 mA or less (single GW unit)
Inputs/outputs points Maximum 64 inputs/64 outputs Maximum 32 inputs/64 outputs
Input/output branches 4 branches (16 inputs/16 outputs per branch) 4 branches (8 inputs/16 outputs per branch)
Input supply current Max. 2.8 A (Max. 0.7 A per branch) Max. 1.4 A (Max. 0.35 A per branch)
Output supply current Max. 3.0 A (Max. 0.75 A per branch)
Branch cable length 5 m or less between connected devices (Total 10 m or less per branch)
Operating temperature/humidity range +5 to +45°C at 35% to 85% RH (without condensation)
Withstand voltage 1000 VAC for 1 minute between terminals and housing
Insulation resistance 2 MΩ or more (500 VDC) between terminals and housing
Enclosure IP65
Weight 470 g

All other specifications are the same as the standard products Series EX500.
For details, refer to the WEB catalog or Best Pneumatics No. 1.

30
ATEX Compliant
Decentralized Serial Wiring (GW System, 4 Branches) Series 56-EX500

How to Order SI Units

56 EX500 S001
ATEX category 3 Applicable solenoid valve: Series SV
II 3G Ex nA II T5 X 5°C�≤ Ta�≤ 45°C
II 3D Ex tD A22 IP67 T52°C X

SI Unit Specifications (56-EX500-S001)

Model 56-EX500-S001
Internal current consumption 100 mA or less
Number of outputs 16 outputs
Output type Sink/NPN (Positive common)
Connection block Solenoid valve (Single, double) Relay output module (1 output, 2 outputs)
Output
Double solenoid valve, relay output module (2 outputs): Max. 8 stations
Connection block stations
Single solenoid valve, relay output module (1 output): Max. 16 stations
Connection block supply current Max. 0.65 A
Enclosure IP67
Operating temperature range Operating: 5 to 45°C Stored: −25 to 70°C (with no freezing and condensation)
Environment Operating humidity range Operating, Stored: 35 to 85%RH (with no condensation)
Withstand voltage 1000 VAC for 1 minute between terminals and housing
Insulation resistance 2 MΩ or more (500 VDC) between terminals and housing
Standards CE marking, UL (CSA)
Weight 115 g
Accessory: Waterproof cap (for M12 connector socket) EX500-AWTS (1 pc.)

How to Order SI Units

56 EX500 Q 0 0 1
ATEX category 3 SI unit type
SI unit COM. 1 For without EX9 output block
Applicable solenoid valve:
0 Sink/NPN (Positive common) 2 For EX9 output block mounting
Series SY/VQC/S0700
1 Source/PNP (Negative common)

II 3G Ex nA II T5 X 5°C�≤ Ta�≤ 45°C


II 3D Ex tD A22 IP67 T54°C X

SI Unit Specifications (56-EX500-Q0)

Model 56-EX500-Q001 56-EX500-Q101


Internal current consumption 100 mA or less
Number of outputs 16 outputs
Output type Sink/NPN (Positive common) Source/PNP (Negative common)
Output Connection block Positive common compatible solenoid valve (single, double) Negative common compatible solenoid valve (single, double)
Connection block stations Double solenoid valve: Max. 8 stations Single solenoid valve: Max. 16 stations
Connection block supply current Max. 0.75 A
Enclosure IP67
Operating temperature range Operating: 5 to 45°C Stored: −25 to 70°C (with no freezing and condensation)
Environment Operating humidity range Operating, Stored: 35 to 85%RH (with no condensation)
Withstand voltage 1000 VAC for 1 minute between terminals and housing
Insulation resistance 2 MΩ or more (500 VDC) between terminals and housing
Standards CE marking, UL (CSA)
Weight 105 g
Accessory: Waterproof cap (for M12 connector socket) EX500-AWTS (1 pc.)

31
ATEX Compliant
Decentralized Serial Wiring (GW System, 4 Branches) Series 56-EX500

How to order

Input manifold When ordering an input block manifold, enter the


Input manifold part no. + Input block part no. together.
EEX500 IB1 E 4 The input block , end block and DIN rail are included in
Input unit specification the input manifold. Refer to How to Order.
Connector type
E M8 connector Example) M8 and M12 on a single manifold
T M12 connector Stations Input block
M M8 and M12 mixed 1 1 station Input unit side 56-EX500-IE1 (2 sets)


Input block
4 4 stations 56-EX500-IE3 (2 sets)
56
-EX

II 3G Ex nA II T5 X 5°C ≤ Ta ≤ 45°C
50
0-I
B1

II 3D Ex tD A22 IP65 T60°C X EEX500-IB1-M4 • • • • • • • 1 set


∗ 56-EX500-IE1 • • • • • • • 2 sets

∗ 56-EX500-IE3 • • • • • • • 2 sets

End block side

Input block
56 EX500 IE 1
Block type
1 M8 connector, 2 inputs, PNP specification
ATEX category 3 2 M8 connector, 2 inputs, NPN specification
3 M12 connector, 2 inputs, PNP specification
4 M12 connector, 2 inputs, NPN specification
5 8-point integrated type, M8 connector, PNP specifications
6 8-point integrated type, M8 connector, NPN specifications

II 3G Ex nA II T5 X 5°C ≤ Ta ≤ 45°C
II 3D Ex tD A22 IP65 T60°C X (Input block 56-EX500-IE1 to 4)
II 3G Ex nA II T5 X 5°C ≤ Ta ≤ 45°C
II 3D Ex tD A22 IP65 T66°C X (Input block 56-EX500-IE5 to 6)

Input unit specification Input block specifications

Model 56-EX500-lB1 Model 56-EX500-IE1,3,5 56-EX500-IE2,4,6


Connection block The EX500 series input block (mixed combination is possible) Input type PNP sensor input NPN sensor input
Max. 8 points (56-EX500-GPR1A) Sensor connector IE1/2/5/6: M8 connector (3 pins), IE3/4: M12 connector (4 pins)
Number of inputs
Max. 16 points (56-EX500-GDN1-X8) Number of inputs IE1/2/3/4: 2 inputs, IE5/6: 8 inputs
Block supply voltage 24 VDC Rated voltage 24 VDC
Max. 0.35 A (56-EX500-GPR1A) Sensor supply current Max. 30 mA/Sensor
Block supply current
Max. 0.7 A (56-EX500-GDN1-X8) Operating temperature range Operating: 5 to 45°C Stored: –25 to 70°C (with no freezing and condensation)
Current consumption 100 mA or less Operating humidity range Operating, Stored: 35 to 85%RH (with no condensation)
Operating temperature range Operating: 5 to 45°C Stored: –25 to 70°C (with no freezing and condensation) Withstand voltage 1000 VAC for 1 minute between terminals and housing
Operating humidity range Operating, Stored: 35 to 85%RH (with no condensation) Insulation resistance 2 MΩ or more (500 VDC) between terminals and housing
Withstand voltage 1000 VAC for 1 minute between terminals and housing Enclosure IP65
Insulation resistance 2 MΩ or more (500 VDC) between terminals and housing Weight IE1/2: 20 g, IE3/4: 40 g, IE5/6: 55 g
Enclosure IP65
Weight Note) 100 g (Input unit + end block)
Note) Not including the DIN rail weight.

32
Air cylinder
ATEX Compliant
Standard: Double Acting, Single Rod

Series 55-C76
ø32, ø40
90°C (T5) Ta –10°C to 40°C
II 2GDc 110°C (T4) Ta 40°C to 60°C

How to Order

Without magnet 55 C76 E 32 50 C XC6A


With magnet 55 CD76 E 32 50 C A XC6A
ATEX category 2 Made to Order
Nil Standard
Built-in magnet for auto switch Stainless steel piston rod
XC6A and rod-end nut
Stainless steel piston rod,
XC6B
Mounting rod-end nut and mounting nut
E Double end XC22∗ Fluororubber seals
F∗ Front nose XC85 Food grade grease
Y∗ Front nose in line port X2018 Long stroke
∗ Except air cushion type. ∗ Only with rubber cushion type.

Bore size
32 32 mm
40 40 mm Auto switch mounting
A Rail mounting
B Band mounting

Cushion
Mounting Bracket Part No. Nil Rubber cushion (Standard)
Bore size C Air cushion (only “E” execution)
(mm) 32 40
Mounting bracket
Foot (1 pc.) C76F32A C76F40A
Accessory Mounting bracket

Foot Cylinder stroke


C76F32B C76F40B X2018
(2 pcs. with mounting nut 1 pc.) Bore size
Standard stroke (Long stroke)
Trunnion C76T32 C76T40 (mm)
Clevis C76C32 C76C40 32 10,25,40,50,80,100
301 to 1000
Single knuckle joint KJ10DA KJ12DA 40 125,160,200,250,300
Double knuckle joint GKM10-20A GKM12-24A
Floating joint JA25-10-150 JA40-12-175 Refer to page 69 for applicable auto switches.

Refer to page 36 for dimensions.

Specifications

Bore size (mm) ø32 ø40


Action Double Acting, Single rod
Fluid Air
Proof pressure 1.5 MPa
Max. operating pressure 1.0 MPa
Min. operating pressure 0.05 MPa
Ambient and fluid temperature −10 to 60°C (No freezing)
Lubrication Not required (Non-lube)
Piston speed 50 to 1000 mm/s
+1.4
Stroke tolerance 0 mm
Cushion Rubber cushion, Air cushion
Port size G1/8 G1/4
Mounting Double end, Front nose, Front nose in line port

33
Air cylinder
ATEX Compliant
Standard: Double Acting, Double Rod

Series 55-C76W
ø32, ø40
90°C (T5) Ta –10°C to 40°C
II 2GDc 110°C (T4) Ta 40°C to 60°C

How to Order

Without magnet 55 C76 WE 32 50 C XC6A


With magnet 55 CD76WE 32 50 C A XC6A
ATEX category 2 Made to Order
Nil Standard
Built-in magnet for auto switch Stainless steel piston rod and
XC6A
rod-end nut
Stainless steel piston rod,
XC6B
Mounting rod-end nut and mounting nut
E Double end type XC22∗ Fluororubber seals
XC85 Food grade lubricant
X2018 Long stroke
∗ Only with rubber cushion type.

Bore size
32 32 mm
40 40 mm Auto switch mounting
A Rail mounting
B Band mounting

Cushion
Mounting Bracket Part No. Nil Rubber cushion (Standard)
Bore size C Air cushion
Mounting (mm) 32 40
bracket
Foot (1 pc.) C76F32A C76F40A
Mounting bracket

Foot Cylinder stroke


(2 pcs. with mounting nut 1 pc.) C76F32B C76F40B Bore size X2018
Standard stroke (Long stroke)
Trunnion C76T32 C76T40 (mm)
Clevis C76C32 C76C40 32 10,25,40,50,80,100,125
301 to 500
Single knuckle 40 160,200,250,300
joint KJ10DA KJ12DA
Accessory

Double knuckle Refer to page 69 for applicable auto switches.


joint GKM10-20A GKM12-24A
Floating Refer to pages 37 and 38 for dimensions.
joint JA25-10-150 JA40-12-175

Specifications

Bore size (mm) ø32 ø40


Action Double Acting, Double Rod
Fluid Air
Proof pressure 1.5 MPa
Max. operating pressure 1.0 MPa
Min. operating pressure 0.05 MPa
Ambient and fluid temperature –10 to 60°C (no freezing)
Lubrication Not required (Non-lube)
Piston speed 50 to 1000 mm/s
+1.4
Stroke tolerance 0 mm
Cushion Rubber cushion, Air cushion
Port size G1/8 G1/4
Mounting Double end

34
ATEX Compliant Air cylinder
Non-rotating Type: Double Acting, Single Rod

Series 55-C76K
ø32, ø40
90°C (T5) Ta –10°C to 40°C
II 2GDc 110°C (T4) Ta 40°C to 60°C

How to Order

Without magnet 55 C76K E 32 50 XC6A


With magnet 55 CD76K E 32 50 A XC6A
ATEX category 2 Made to Order
Nil Standard
Built-in magnet for auto switch Stainless steel piston rod and
XC6A
rod-end nut
Stainless steel piston rod,
XC6B
Mounting rod-end nut and mounting nut
E Double end X2018 Long stroke
F Front nose
Y Front nose in line port

Auto switch mounting


Bore size A Rail mounting
32 32 mm B Band mounting
40 40 mm

Cylinder stroke
Bore size X2018
Standard stroke (Long stroke)
(mm)
Mounting Bracket Part No. 32 10,25,40,50,80,100
Bore size 301 to 1000
Mounting 40 125,160,200,250,300
(mm) 32 40
bracket
Foot (1 pc.) C76F32A C76F40A
Mounting bracket

Foot
(2 pcs. with mounting nut 1 pc.) C76F32B C76F40B
Trunnion C76T32 C76T40
Clevis C76C32 C76C40
Single knuckle
joint KJ10DA KJ12DA
Accessory

Refer to page 69 for applicable auto switches.


Double knuckle
joint GKM10-20A GKM12-24A
Floating Refer to page 36 for dimensions.
joint JA25-10-150 JA40-12-175

Specifications

Bore size (mm) ø32 ø40


Action Double Acting, Single Rod
Fluid Air
Proof pressure 1.5 MPa
Max. operating pressure 1.0 MPa
Min. operating pressure 0.05 MPa
Ambient and fluid temperature –10 to 60°C (No freezing)
Lubrication Not required (Non-lube)
Piston speed 50 to 1000 mm/s
+1.4
Stroke tolerance 0 mm
Cushion Rubber cushion
Port size G1/8 G1/4
Non-rotating accuracy ±0.5° ±0.5°
Mounting Double end, Front nose, Front nose in line port
35
55-C76
ATEX Compliant Air cylinder
Standard: Double Acting, Single Rod Series

Dimensions
Double Acting, Single Rod
Rod foot, Head foot (Flange): C76F32 A A
B, C76F40 B

W LT

TF

UR
NH
XS AU
LS + Stroke TR 12-øAB
XL + Stroke AO US

Rod trunnion, Head trunnion: C76T32, C76T40

øTDe8 øTDe8
TZ

TZ
Port Port
XB NB XC + Stroke

Rod clevis, Head clevis: C76C32, C75C40

XB XC + Stroke
CZ

CW
CH

LT
LT

CO 4-øAB CO
4-øAB
CE CR CT CE CR
CG CU CG

(mm)
Bore Rod foot, Head foot (Flange) Rod trunnion, Head trunnion Rod clevis, Head clevis
size AB AO AU LS LT NH TF TR UR US W XL XS NB TDe8 TZ XB XC AB CE CG CH CO CR CT CU CW CZ LT XB XC
32 7 7 14 96 4 28 28 52 49 66 34 120 48 34.5 10–0.025
–0.047 47.9 47 97 7 9 41 35 4 24 20 46.8 13 57.9 4 47 97
40 9 10 20 129 5 33 30 60 58 80 40 154 60 42.5 12–0.032
–0.059 59.3 57 122 9 12 52 40 3 30 28 58.2 17 72.3 5 57 122

36
55-C76
ATEX Compliant Air cylinder
Standard: Double Acting, Double Rod Series

Dimensions
Double Acting, Double Rod
Rubber cushion: C76WE Bore size Stroke 
Without magnet, Built-in magnet

BE
øKV
K XB XB + Stroke
WH G EE EE G WH + Stroke
SW

8
H
BE K
2-øEh8

øD

45°

NB
øC

øC

øTD H9
KK

AM KW 1.5 4-TC 1.5


TW
FA N N FA AM
H S + Stroke H + Stroke
Rail mounting (A) Band mounting (B)
ZZ + 2 x Stroke Without magnet

Air cushion: C76WE Bore size Stroke C 


Built-in magnet

Cushion valve

WA WA WB
R
H

8 45°

N N
Rail mounting (A) Band mounting (B)
Without magnet

(mm)
Bore size AM BE C D Eh8 EE FA G H HR K KK KV WB KW N NB S SW TC TDH9 TW WH XB ZZ WA
20 M30 x 1.5 12 37.5 30–0.033 G 1/8 30 9 58 23.8 10 M10 x 1.5 38 11 7 17(19) 34.5 68 17 M8 x 1 10 +0.036
0
32 0 34.5 38 47 184 15.3
0
40 24 M38 x 1.5 14 46.5 38–0.039 G 1/4 35 12 69 28.3 12 M12 x 1.75 50 13 8 22(25) 42.5 89 19 M10 x 1 12 +0.043
0 42.5 45 57 227 20
( ): In the case of air cushion

37
55-C76
ATEX Compliant Air cylinder
Standard: Double Acting, Double Rod Series

Dimensions
Double Acting, Double Rod
Rod foot, Head foot (Flange): C76F32 A A
B, C76F40 B

W LT

TF

UR
NH
XS AU
LS + Stroke XT + Stroke TR 12-øAB
XL + Stroke AO US

Rod trunnion, Head trunnion: C76T32, C76T40

ø TDe8
TZ

Port
XB XC + Stroke NB

Clevis type: C76C32, C75C40

XB XC + Stroke CZ

CW
CH
LT

CO
4-øAB
CE CR CT
CG CU

(mm)
Bore Rod foot, Head foot (Flange) Rod trunnion, Head trunnion Clevis
size AB AO AU LS LT NH TF TR UR US W XL XS XT NB TDe8 TZ XB XC AB CE CG CH CO CR CT CU CW CZ LT XB XC
32 7 7 14 96 4 28 28 52 49 66 34 120 48 24 34.5 10 –0.025
–0.047 47.9 47 97 7 9 41 35 4 24 20 46.8 13 57.9 4 47 97
40 9 10 20 129 5 33 30 60 58 80 40 154 60 25 42.5 12 –0.032
–0.059 59.3 57 122 9 12 52 40 3 30 28 58.2 17 72.3 5 57 122

38
Series 55-C76
Accessories
Single knuckle joint (DIN648 compliant) Double knuckle joint (DIN7151 compliant)
D

45°

D3
D
B1

B3

øF

α α L

L3

øJ
G

E
C
D6

D7

L2

H
(mm) (mm)
Bore size Model Thread D3 DH7 H D6 B3 B1 L D7 α ° L3 Bore size Model Thread E B D F G C J L2
32 KJ10DA M10 x 1.5 10 43 20 10.5 14 20 19 13 14 32 GKM10-20A M10 x 1.5 10 40 10 18 20 12 20
40 KJ12DA M12 x 1.75 12 50 30 12 16 22 22 13 16 40 GKM12-24A M12 x 1.75 12 48 12 23 24 15 24

Floating joint/Series JA
JA25/40 M
M
U

øD
U

F
G

B E P H

(mm)
M Maximum Allowable Max. operating
Bore size Model screwed depth eccentricity tension and
Nominal A B D E F G H compression power
Pitch P U
thread dia. (kN)
32 JA25-10-150 10 1.5 49.5 19.5 24 5 8 8 17 9 0.5 2.5
40 JA40-12-175 12 1.75 60 20 31 6 11 11 22 13 0.75 4.4

39
ISO Cylinder [ISO/6432]
ATEX Compliant
Standard: Double Acting, Single Rod

Series 55-C85
ø8, ø10, ø12, ø16, ø20, ø25
90°C (T5) Ta –10°C to 40°C
II 2GDc 110°C (T4) Ta 40°C to 60°C

How to Order

Without magnet 55 C85 N 16 40 C XC6A


With magnet 55 CD85 N 16 40 C A XC6A
ATEX category 2 Made to Order
Nil Standard
Built-in magnet for auto switch Stainless steel piston
XC6A
rod and rod-end nut
Mounting Stainless steel piston rod,
XC6B
N∗ Basic (integrated clevis) rod-end nut and mounting nut
E Double end XC22 Fluororubber seals
F Front nose X2018 Long stroke
Y Front nose in line port
∗ Air cushion type is available for N
type only.

Auto switch mounting type


Specifications A Rail mounting
B Band mounting
Please order auto switches and
Bore size (mm) 8 10 12 16 20 25 bands separately.
Action Double Acting, Single Rod
Fluid Air
Proof pressure 1.5 MPa
Max. operating pressure 1.0 MPa Cushion
Min. operating pressure 0.1 MPa 0.08 MPa 0.05 MPa Nil Rubber cushion (Standard)
Ambient and fluid temperature –10 to 60°C (No freezing) Air cushion
C
(Only “N” execution, bores 10 to 25 mm)
Lubrication Not required (Non-lube)
Piston speed Air cushion: 50 to 1000 mm/s, Rubber cushion: 50 to 750 mm/s
+1.0 +1.4
Stroke tolerance 0 mm 0 mm
Cushion Rubber cushion Rubber cushion, Air cushion Bore size Cylinder stroke
Port size M5X0.8 G1/8 Bore size
Standard stroke (mm)∗∗
X2018
Mounting Integrated clevis, Double end, Front nose, Front nose in line port (mm) (Long stroke)
8∗ 101 to 200
10, 25, 40, 50, 80, 100
10 101 to 400
12 10, 25, 40, 50, 80, 100
125, 160, 200 201 to 400
16
20 10, 25, 40, 50, 80, 100
301 to 1000
25 125, 160, 200, 250, 300
∗ Not available with air cushion.
Mounting Bracket Part No. ∗∗ Other strokes available on request.
Bore size
Mounting (mm) 8 10 12 16 20 25
bracket
Foot (1 pc.) C85L10A C85L16A C85L25A
Mounting bracket

Foot All other specifications are the same as the


(2 pcs. with mounting nut 1 pc.) C85L10B C85L16B C85L25B standard products Series C85.
For details, refer to the WEB catalog or
Flange C85F10 C85F16 C85F25
ISO Cylinder (CAT.P-E10-2).
Trunnion C85T10 C85T16 C85T25
Clevis C85C10 C85C16 C85C25 Refer to page 69 for applicable auto switches.
Single knuckle KJ8D KJ10D
KJ4D KJ6D
joint
Accessory

Double knuckle GKM8 GKM10


GKM4-8 GKM6-10
joint -16 -20
Floating JA20 JA30
joint JA10-4-070 JA15-6-100
-8-125 -10-125

40
ISO Cylinder [ISO/6432]
ATEX Compliant
Standard: Double Acting, Double Rod

Series 55-C85W
ø8, ø10, ø12, ø16, ø20, ø25
90°C (T5) Ta –10°C to 40°C
II 2GDc 110°C (T4) Ta 40°C to 60°C

How to Order

Without magnet 55 C85W E 16 40 C XC6A


With magnet 55 CD 85WE 16 40 C B XC6A
ATEX category 2 Made to Order
Nil Standard
Stainless steel piston
XC6A
rod and rod-end nut
Built-in magnet for auto switch
Stainless steel piston rod,
XC6B
rod-end nut and mounting nut
XC22 Fluororubber seals
Mounting X2018 Long stroke
E Double end

Auto switch mounting type


Specifications A Rail mounting
B Band mounting
Please order auto switches and
Bore size (mm) 8 10 12 16 20 25 bands separately.
Action Double Acting, Double Rod
Fluid Air
Proof pressure 1.5 MPa
Max. operating pressure 1.0 MPa Cushion
Min. operating pressure 0.1 MPa 0.08 MPa 0.05 MPa Nil Rubber cushion (Standard)
Ambient and fluid temperature –10 to 60°C (No freezing) Air cushion
C
(Only “N” execution, bores 10 to 25 mm)
Lubrication Not required (Non-lube)
Piston speed Air cushion: 50 to 1000 mm/s, Rubber cushion: 50 to 750 mm/s
+1.0 +1.4
Stroke tolerance 0 mm 0 mm
Cushion Rubber cushion Rubber cushion, Air cushion Bore size Cylinder stroke
Port size M5X0.8 G1/8 Bore size X2018
(mm) Standard stroke (mm)∗∗ (Long stroke)
Mounting Double end
8∗
10, 25, 40, 50, 80, 100 —
10
12 10, 25, 40, 50, 80, 100
125, 160, 200 —
16
20 10, 25, 40, 50, 80, 100
125, 160, 200, 250, 300 301 to 500
25
∗ Not available with air cushion.
Mounting Bracket Part No. ∗∗ Other strokes available on request.
Bore size
Mounting (mm) 8 10 12 16 20 25
bracket
Foot (1 pc.) C85L10A C85L16A C85L25A
Mounting bracket

Foot All other specifications are the same as the


(2 pcs. with mounting nut 1 pc.) C85L10B C85L16B C85L25B standard products Series C85W.
For details, refer to the WEB catalog or
Flange C85F10 C85F16 C85F25
ISO Cylinder (CAT.P-E10-2).
Trunnion C85T10 C85T16 C85T25
Clevis C85C10 C85C16 C85C25 Refer to page 69 for applicable auto switches.
Single knuckle KJ8D KJ10D
KJ4D KJ6D
joint
Accessory

Double knuckle GKM8 GKM10


GKM4-8 GKM6-10
joint -16 -20
Floating JA20 JA30
joint JA10-4-070 JA15-6-100
-8-125 -10-125

41
ISO Cylinder [ISO/6432]
ATEX Compliant
Non-rotating Type: Double Acting, Single Rod

Series 55-C85K
ø8, ø10, ø12, ø16, ø20, ø25
90°C (T5) Ta –10°C to 40°C
II 2GDc 110°C (T4) Ta 40°C to 60°C

How to Order

Without magnet 55 C85 K N 16 40 XC6A


With magnet 55 CD 85K N 16 40 A XC6A
ATEX category 2 Made to Order
Nil Standard
Built-in magnet for auto switch Stainless steel piston rod
XC6A
and rod-end nut
Stainless steel piston rod,
XC6B
rod-end nut and mounting nut
Mounting
X2018 Long stroke
N Basic (integrated clevis)
E Double end
F Front nose
Y Front nose in line port

Auto switch mounting type


Specifications A Rail mounting
B Band mounting
Please order auto switches and
Bore size (mm) 8 10 12 16 20 25 bands separately.
Action Double Acting, Single Rod
Fluid Air
Proof pressure 1.5 MPa
Max. operating pressure 1.0 MPa
Min. operating pressure 0.1 MPa 0.08 MPa 0.05 MPa
Ambient and fluid temperature –10 to 60°C (No freezing)
Lubrication Not required (Non-lube) Bore size Cylinder stroke
Piston speed Rubber cushion: 50 to 750 mm/s Bore size X2018
+1.0 +1.4 (mm) Standard stroke (mm)∗ (Long stroke)
Stroke tolerance 0 mm 0 mm
Cushion Rubber cushion 8 101 to 200
10, 25, 40, 50, 80, 100
Port size M5X0.8 G1/8 10 101 to 400
12 10, 25, 40, 50, 80, 100
Non-rotating accuracy ±1.5° ±1° ±0.7° 201 to 400
16 125, 160, 200
Mounting Integrated clevis, Double end, Front nose, Front nose in line port 20 10, 25, 40, 50, 80, 100
125, 160, 200, 250, 300 301 to 1000
25
∗ Other strokes available on request.

Mounting Bracket Part No.


All other specifications are the same as the
Bore size
Mounting (mm) 8 10 12 16 20 25 standard products Series C85K.
bracket For details, refer to the WEB catalog or
Foot (1 pc.) C85L10A C85L16A C85L25A ISO Cylinder (CAT.P-E10-2).
Mounting bracket

Foot
(2 pcs. with mounting nut 1 pc.) C85L10B C85L16B C85L25B
Refer to page 69 for applicable auto switches.
Flange C85F10 C85F16 C85F25
Trunnion C85T10 C85T16 C85T25
Clevis C85C10 C85C16 C85C25
Single knuckle KJ8D KJ10D
KJ4D KJ6D
joint
Accessory

Double knuckle GKM8 GKM10


GKM4-8 GKM6-10
joint -16 -20
Floating JA20 JA30
joint JA10-4-070 JA15-6-100
-8-125 -10-125

42
ISO Cylinder
ATEX Compliant
Standard: Double Acting, Single Rod

Series 55-C95
ø160, ø200, ø250
95°C (T5) Ta –10°C to 40°C
II 2GDc 115°C (T4) Ta 40°C to 60°C

How to Order

Without magnet 55 C95S B 160 100 XC6


With magnet 55 C95SD B 160 100 XC6
ATEX category 2 Made to Order
Nil Standard
Built-in magnet for auto switch XA Change of rod end shape
Stainless steel
Mounting XC6 piston rod
B Basic/without bracket and rod-end nut
L Axial foot Bore size Change of trunnion
F Rod side flange 160 160 mm XC14∗ bracket mounting
G Head side flange 200 200 mm position (Rod side)
C Single clevis 250 250 mm ∗ Simple specials part no. except for XC14A or B.
D Double clevis
T Centre trunnion Cylinder stroke
Maximum Stroke
Bore size
(mm) Standard XC6 XC14
Specifications 160 2000 1600 2000
200 2000 1600 2000
250 2400 1500 2400
Bore size (mm) ø160 ø200 ø250
∗ Please consult with SMC for longer strokes.
Action Double Acting, Single Rod
Fluid Air
Proof pressure 1.5 MPa Class 2 Pressure Vessel
Max. operating pressure 1.0 MPa Series C95 can not be used as the Class 2 Pressure
Min. operating pressure 0.05 MPa Vessels. If the stroke exceeds the following values, the
cylinder with such stroke can not be installed or used in
Ambient and fluid temperature –10 to 60°C (No freezing) Japan.
Lubrication Not required (Non-lube) Bore size (mm) Cylinder stroke (mm)
Piston speed 50 to 500 mm/s 160 1987
+1.0 +1.4 +1.8
to 250: 0 ,
251 to 1000: 0 ,
1001 to 1500: 0 200 998
Stroke tolerance +2.2 +2.6 250
1501 to 2000: 0 , 2001 to 2400: 0 813
Cushion Both ends (Air cushion)
Port size G3/4 G3/4 G1
Basic, Axial foot, Rod side flange, Head side flange, All other specifications are the same as the
Mounting Single clevis, Double clevis, Centre trunnion standard products Series C95.

Refer to page 69 for applicable auto switches.

Mounting Bracket, Mounting Accessories


Description Bore size ø160 ø200 ø250
L Foot L5160 L5200 L5250
F, G Flange F5160 F5200 F5250
C Single clevis C5160 C5200 C5250
D Double clevis D5160 D5200 D5250
GKM Rod clevis (2) GKM35-54 GKM40-84
Piston rod (3)
KJ KJ36D KJ42D
ball joint
Note 1) Accessories for each mounting bracket are as follows.
Foot, Flange, Single clevis: Mounting bolts
Double clevis: Mounting bolts, Clevis pin
Note 2) GKM according to ISO 8140
Note 3) KJ according to ISO 8139

43
ISO Cylinder
ATEX Compliant
Standard: Double Acting, Double Rod

Series 55-C95W
ø160, ø200, ø250
95°C (T5) Ta –10°C to 40°C
II 2GDc 115°C (T4) Ta 40°C to 60°C

How to Order

Without magnet 55 C95S B 160 100 W XC6


With magnet 55 C95SD B 160 100 W XC6
ATEX category 2
Made to Order
Built-in magnet for auto switch
Nil Standard
XA Change of rod end shape
Mounting
Stainless steel piston rod and
B Basic/without bracket XC6
rod-end nut (ø32 to ø100)
L Axial foot Change of trunnion bracket
F Rod side flange XC14 ∗
mounting position
T Centre trunnion
∗ Simple specials part no. except for XC14A or B.

Bore size
Cylinder stroke
160 160 mm
Maximum Stroke
200 200 mm
250 250 mm Bore size
Standard XC6 XC14
(mm)
160 1200 1200 1200
200 1200 1200 1200
Specifications 250 1200 1200 1200
∗ Please consult with SMC for longer strokes.

Bore size (mm) ø160 ø200 ø250


Action Double Acting, Double Rod Class 2 Pressure Vessel
Fluid Air Series C95 can not be used as the Class 2 Pressure
Proof pressure 1.5 MPa Vessels. If the stroke exceeds the following values, the
Max. operating pressure 1.0 MPa cylinder with such stroke can not be installed or used in
Japan.
Min. operating pressure 0.05 MPa
Ambient and fluid temperature –10 to 60°C (No freezing) Bore size (mm) Cylinder stroke (mm)
200 998
Lubrication Not required (Non-lube)
250 813
Piston speed 50 to 500 mm/s
+1.0 +1.4 +1.8
to 250: 0 , 251 to 1000: 0 , 1001 to 1500: 0
Stroke tolerance +2.2 +2.6
1501 to 2000: 0 , 2001 to 2400: 0 All other specifications are the same as the
Cushion Both ends (Air cushion) standard products Series C95W.
Port size G3/4 G3/4 G1
Mounting Basic, Axial foot, Rod side flange, Centre trunnion Refer to page 69 for applicable auto switches.

Mounting Bracket, Mounting Accessories


Bore size
Description ø160 ø200 ø250
L Foot L5160 L5200 L5250
F Flange F5160 F5200 F5250
GKM Rod clevis (2) GKM35-54 GKM40-84
Piston rod (3)
KJ KJ36D KJ42D
ball joint
Note 1) Mounting bolts are shipped together for foot style and flange style.
Note 2) GKM according to ISO 8140
Note 3) KJ according to ISO 8139

44
ISO Cylinder
ATEX Compliant
Standard: Double Acting, Single Rod

Series 55-C96
ø32, ø40, ø50, ø63, ø80, ø100, ø125
Without magnet Built-in magnet
II 2GDc 85°C (T5) Ta –20°C to 40°C 85°C (T5) Ta –10°C to 40°C
105°C (T4) Ta 40°C to 60°C 105°C (T4) Ta 40°C to 60°C

How to Order

Without magnet 55 C96S B 32 100 XC68


With magnet 55 C96SD B 32 100 XC68
ATEX category 2 Made to Order
Nil Standard
XA Change of rod end shape
Built-in magnet for auto switch XC4 With heavy duty scraper (ø32 to ø100)
Tie-rod, cushion valve, tie-rod nut,
XC7
etc. made of stainless steel
XC14∗ Change of trunnion bracket mounting position
Mounting XC18 NPT ports
B Basic/without bracket XC22 Fluororubber seals
L Axial foot With chrome plated stainless steel
F Rod side flange XC68
piston rod and stainless steel nut
G Head side flange ∗ Simple specials part no. except for XC14A or B.
C Single clevis
D Double clevis
T Centre trunnion Cylinder stroke (mm)
Bore size Standard max. XC68
Standard stroke (mm)
(mm) stroke Note) Max. stroke
Bore size 25, 50, 80, 100, 125, 160, 200
32 1000 1000
250, 320, 400, 500
32 32 mm
25, 50, 80, 100, 125, 160, 200
40 40 mm 40 1900 1700
250, 320, 400, 500
50 50 mm
25, 50, 80, 100, 125, 160, 200
63 63 mm 50 1900 1700
250, 320, 400, 500, 600
80 80 mm
25, 50, 80, 100, 125, 160, 200
100 100 mm 63 1900 1700
250, 320, 400, 500, 600
125 125 mm
25, 50, 80, 100, 125, 160, 200
80 1900 1700
250, 320, 400, 500, 600, 700, 800
25, 50, 80, 100, 125, 160, 200
100 1900 1700
250, 320, 400, 500, 600, 700, 800
125 — 2000 1600
Intermediate strokes are available.
∗ Please consult with SMC for longer strokes.

All other specifications are the same as the


standard products Series C96.
For details, refer to the WEB catalog or
ISO Cylinder (CAT.P-E10-2).

Refer to page 69 for applicable auto switches.

45
ISO Cylinder
ATEX Compliant
Standard: Double Acting, Double Rod

Series 55-C96W
ø32, ø40, ø50, ø63, ø80, ø100, ø125
Without magnet Built-in magnet
II 2GDc 85°C (T5) Ta –20°C to 40°C 85°C (T5) Ta –10°C to 40°C
105°C (T4) Ta 40°C to 60°C 105°C (T4) Ta 40°C to 60°C

How to Order

Without magnet 55 C96S B 32 100 W XC68


With magnet 55 C96SD B 32 100 W XC68
ATEX category 2 Made to Order
Nil Standard
XA Change of rod end shape
Built-in magnet for auto switch XC4 With heavy duty scraper (ø32 to ø100)
Tie-rod, cushion valve, tie-rod nut,
XC7
etc. made of stainless steel
XC14∗ Change of trunnion bracket mounting position
Mounting XC18 NPT ports
B Basic/without bracket XC22 Fluororubber seals
L Axial foot With chrome plated stainless steel
F Rod side flange XC68
piston rod and stainless steel nut
T Centre trunnion ∗ Simple specials part no. except for XC14A or B.

Bore size Rod


W Double rod
32 32 mm
40 40 mm
50 50 mm
63 63 mm
80 80 mm Cylinder stroke(mm)
100 100 mm Bore size Standard stroke (mm) Max. stroke∗
125 125 mm (mm)
25, 50, 80, 100, 125, 160, 200
32 250, 320, 400, 500
1000
25, 50, 80, 100, 125, 160, 200
40 250, 320, 400, 500
1000
25, 50, 80, 100, 125, 160, 200
50 250, 320, 400, 500, 600
1000
25, 50, 80, 100, 125, 160, 200
63 250, 320, 400, 500, 600
1000
25, 50, 80, 100, 125, 160, 200
80 1000
250, 320, 400, 500, 600, 700, 800
25, 50, 80, 100, 125, 160, 200
100 1000
250, 320, 400, 500, 600, 700, 800
125 — 1000
Intermediate strokes are available.
∗ Please consult with SMC for longer strokes.

All other specifications are the same as the


standard products Series C96W.
For details, refer to the WEB catalog or
ISO Cylinder (CAT.P-E10-2).

Refer to page 69 for applicable auto switches.

46
ATEX Compliant ISO Cylinder
Non-rotating Type: Double Acting, Single Rod

Series 55-C96K
ø32, ø40, ø50, ø63, ø80, ø100
Without magnet Built-in magnet
II 2GDc 85°C (T5) Ta –20°C to 40°C 85°C (T5) Ta –10°C to 40°C
105°C (T4) Ta 40°C to 60°C 105°C (T4) Ta 40°C to 60°C

How to Order

Without magnet 55 C96K B 32 100


With magnet 55 C96KD B 32 100
ATEX category 2 Cylinder stroke (mm)
Bore size
Maximum stroke (mm)
(mm)
Built-in magnet for auto switch 32 500
40 500
50 600
63 600
Mounting 80 800
B Basic/without bracket 100 800
L Axial foot
F Rod side flange
G Head side flange
C Single clevis
D Double clevis
T Centre trunnion

Bore size
32 32 mm
40 40 mm
50 50 mm
63 63 mm
80 80 mm
100 100 mm

All other specifications are the same as the


standard products Series C96.
For details, refer to the WEB catalog or
ISO Cylinder (CAT.P-E10-2).

Refer to page 69 for applicable auto switches.

47
ATEX Compliant ISO Cylinder
Non-rotating Type: Double Acting, Double Rod

Series 55-C96KW
ø32, ø40, ø50, ø63, ø80, ø100
Without magnet Built-in magnet
II 2GDc 85°C (T5) Ta –20°C to 40°C 85°C (T5) Ta –10°C to 40°C
105°C (T4) Ta 40°C to 60°C 105°C (T4) Ta 40°C to 60°C

How to Order

Without magnet 55 C96K B 32 100 W


With magnet 55 C96KD B 32 100 W
ATEX category 2 Rod
W Double rod

Built-in magnet for auto switch

Cylinder stroke (mm)


Mounting Bore size
Maximum stroke (mm)
B Basic/without bracket (mm)
L Axial foot 32 500
F Rod side flange 40 500
T Centre trunnion 50 600
63 600
80 800
100 800
Bore size
32 32 mm
40 40 mm
50 50 mm
63 63 mm
80 80 mm
100 100 mm

All other specifications are the same as the


standard products Series C96W.
For details, refer to the WEB catalog or
ISO Cylinder (CAT.P-E10-2).

Refer to page 69 for applicable auto switches.

48
ATEX Compliant ISO Cylinder
Smooth cylinder: Double Acting, Single Rod

Series 55-C96Y
ø32, ø40, ø50, ø63, ø80, ø100, ø125
Without magnet Built-in magnet
II 2GDc 85°C (T5) Ta –20°C to 40°C 85°C (T5) Ta –10°C to 40°C
105°C (T4) Ta 40°C to 60°C 105°C (T4) Ta 40°C to 60°C

How to Order

Without magnet 55 C96Y B 32 100


With magnet 55 C96YD B 32 100
ATEX category 2 Cylinder stroke (mm)
Bore size
Maximum stroke (mm)
(mm)
Built-in magnet for auto switch 32 800
40 800
50 1000
63 1000
Mounting 80 1000
B Basic/without bracket 100 1000
L Axial foot 125 1000
F Rod side flange
G Head side flange
C Single clevis
D Double clevis
T Centre trunnion

Bore size
32 32 mm
40 40 mm
50 50 mm
63 63 mm
80 80 mm
100 100 mm
125 125 mm

All other specifications are the same as the


standard products Series C96.
For details, refer to the WEB catalog or
ISO Cylinder (CAT.P-E10-2).

Refer to page 69 for applicable auto switches.

49
ISO Cylinder
ATEX Compliant
Standard: Double Acting, Single Rod

Series 55-CP96
ø32, ø40, ø50, ø63, ø80, ø100, ø125
Without magnet Built-in magnet
II 2GDc 85°C (T5) Ta –20°C to 40°C 85°C (T5) Ta –10°C to 40°C
105°C (T4) Ta 40°C to 60°C 105°C (T4) Ta 40°C to 60°C

How to Order

Without magnet 55 CP96S B 32 100 XC68


With magnet 55 CP96SD B 32 100 XC68
ATEX category 2
Made to Order
Built-in magnet for auto switch Nil Standard
XA Change of rod end shape
XC4 With heavy duty scraper (ø32 to ø100)
Mounting Tie-rod, cushion valve, tie-rod nut,
B Basic/without bracket XC7
etc. made of stainless steel
L Axial foot XC18 NPT ports
F Rod side flange XC22 Fluororubber seals
G Head side flange With chrome plated stainless steel
C Single clevis XC68
piston rod and stainless steel nut
D Double clevis

Bore size
32 32 mm
40 40 mm
50 50 mm
63 63 mm
80 80 mm
100 100 mm
125 125 mm

Cylinder stroke (mm)


Bore size XC68
Standard stroke (mm) Max. stroke∗
(mm) Max. stroke
25, 50, 80, 100, 125, 160, 200
32 250, 320, 400, 500 2000 1800
25, 50, 80, 100, 125, 160, 200
40 250, 320, 400, 500 2000 1700
25, 50, 80, 100, 125, 160, 200
50 250, 320, 400, 500, 600 2000 1700
25, 50, 80, 100, 125, 160, 200
63 250, 320, 400, 500, 600 2000 1700
25, 50, 80, 100, 125, 160, 200
80 250, 320, 400, 500, 600, 700, 800 2000 1700
25, 50, 80, 100, 125, 160, 200
100 250, 320, 400, 500, 600, 700, 800 2000 1700
All other specifications are the same as the
125∗∗ — 2000 1600 standard products Series CP96.
Intermediate strokes are available. For details, refer to the WEB catalog or
∗ Please consult with SMC for longer strokes. ISO Cylinder (CAT.P-E10-2).
∗∗ ø125 are produced upon receipt of order.
Refer to page 69 for applicable auto switches.

50
ISO Cylinder
ATEX Compliant
Standard: Double Acting, Double Rod

Series 55-CP96W
ø32, ø40, ø50, ø63, ø80, ø100, ø125
Without magnet Built-in magnet
II 2GDc 85°C (T5) Ta –20°C to 40°C 85°C (T5) Ta –10°C to 40°C
105°C (T4) Ta 40°C to 60°C 105°C (T4) Ta 40°C to 60°C

How to Order

Without magnet 55 CP96S B 32 100 W XC68


With magnet 55 CP96SD B 32 100 W XC68
ATEX category 2
Made to Order
Nil Standard
Built-in magnet for auto switch XA Change of rod end shape
XC4 With heavy duty scraper (ø32 to ø100)
Tie-rod, cushion valve, tie-rod nut,
XC7
etc. made of stainless steel
Mounting XC18 NPT ports
B Basic/without bracket XC22 Fluororubber seals
L Axial foot With chrome plated stainless steel
F Rod side flange XC68
piston rod and stainless steel nut

Rod
Bore size W Double rod
32 32 mm
40 40 mm
50 50 mm
63 63 mm
Cylinder stroke (mm)
80 80 mm Bore size Max. stroke for standard
Standard stroke (mm)
100 100 mm (mm) type and XC68∗
125 125 mm 25, 50, 80, 100, 125, 160, 200
32 250, 320, 400, 500 1000
25, 50, 80, 100, 125, 160, 200
40 250, 320, 400, 500 1000
25, 50, 80, 100, 125, 160, 200
50 250, 320, 400, 500, 600 1000
25, 50, 80, 100, 125, 160, 200
63 250, 320, 400, 500, 600 1000
25, 50, 80, 100, 125, 160, 200
80 250, 320, 400, 500, 600, 700, 800 1000
25, 50, 80, 100, 125, 160, 200
100 250, 320, 400, 500, 600, 700, 800 1000
125∗∗ — 1000
Intermediate strokes are available.
∗ Please consult with SMC for longer strokes.
∗∗ ø125 are produced upon receipt of order.

All other specifications are the same as the


standard products Series CP96W.
For details, refer to the WEB catalog or
ISO Cylinder (CAT.P-E10-2).

Refer to page 69 for applicable auto switches.

51
ATEX Compliant ISO Cylinder
Non-rotating Type: Double Acting, Single Rod

Series 55-CP96K
ø32, ø40, ø50, ø63, ø80, ø100
Without magnet Built-in magnet
II 2GDc 85°C (T5) Ta –20°C to 40°C 85°C (T5) Ta –10°C to 40°C
105°C (T4) Ta 40°C to 60°C 105°C (T4) Ta 40°C to 60°C

How to Order

Without magnet 55 CP96K B 32 100


With magnet 55 CP96KD B 32 100
ATEX category 2 Cylinder stroke (mm)
Bore size Maximum stroke
(mm) (mm)
Built-in magnet for auto switch 32 500
40 500
50 600
63 600
Mounting 80 800
B Basic/without bracket 100 800
L Axial foot
F Rod side flange
G Head side flange
C Single clevis
D Double clevis

Bore size
32 32 mm
40 40 mm
50 50 mm
63 63 mm
80 80 mm
100 100 mm
All other specifications are the same as the
standard products Series CP96.
For details, refer to the WEB catalog or
ISO Cylinder (CAT.P-E10-2).

Refer to page 69 for applicable auto switches.

52
ATEX Compliant ISO Cylinder
Non-rotating Type: Double Acting, Double Rod

Series 55-CP96KW
ø32, ø40, ø50, ø63, ø80, ø100
Without magnet Built-in magnet
II 2GDc 85°C (T5) Ta –20°C to 40°C 85°C (T5) Ta –10°C to 40°C
105°C (T4) Ta 40°C to 60°C 105°C (T4) Ta 40°C to 60°C

How to Order

Without magnet 55 CP96K B 32 100 W


With magnet 55 CP96KD B 32 100 W
ATEX category 2
Rod
W Double rod
Built-in magnet for auto switch

Cylinder stroke (mm)


Bore size Maximum stroke
Mounting (mm) (mm)
B Basic/without bracket 32 500
L Axial foot 40 500
F Rod side flange 50 600
63 600
80 800
100 800

Bore size
32 32 mm
40 40 mm
50 50 mm
63 63 mm
80 80 mm
100 100 mm

All other specifications are the same as the


standard products Series CP96W.
For details, refer to the WEB catalog or
ISO Cylinder (CAT.P-E10-2).

Refer to page 69 for applicable auto switches.

53
ATEX Compliant ISO Standards
Compact Cylinder/Standard type: Double acting, Single rod

Series 55-C55
ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100
85°C(T6) Ta -10°C to 40°C
II 2GDc 105°C(T4) Ta 40°C to 60°C

How to Order

Without magnet 55 C55 B 20 10


With magnet 55 CD55 B 20 10
ATEX category 2

Built-in magnet for auto switch

Mounting
B Through-hole/Both ends tapped common (Standard)
L Foot
F Rod side flange
G Head side flange
C Single clevis
Body option
Nil Standard (Rod end female thread)
Bore size M Rod end male thread
20 20 mm
25 25 mm
Cylinder stroke (mm)
32 32 mm
Bore size (mm) Standard stroke (mm)
40 40 mm
5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 60, 80
50 50 mm 20 to 63 100, 125, 150
63 63 mm
10, 15, 20, 25, 30, 35, 40, 45, 50, 60, 80
80 80 mm 80, 100 100, 125
100 100 mm

All other specifications are the same as the standard products Series C55.
For details, refer to the WEB catalog or ISO Cylinder (CAT.P-E10-2).

Refer to page 69 for applicable auto switches.

54
ATEX Compliant
Air Cylinder/Standard type: Double acting, Single rod

Series 55-CG1
ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100
95°C (T5) Ta –10°C to 40°C
II 2GDc 115°C (T4) Ta 40°C to 60°C

How to Order

Without magnet 55 CG1 L N 25 100 XC85


With magnet 55 CDG1 L N 25 100 XC85
ATEX category 2
Made to Order
Nil Standard
Built-in magnet for auto switch XC85 Food grade grease
XC10 Note 1) Dual stroke cylinder/Double rod
Port thread type XC11 Note 1) 2) Dual stroke cylinders/Single rod
Mounting Rubber cushion
Note 1) “How to Order” for XC10, and XC11
B Basic Nil Rc ø20 to ø100 are different from the above. Refer
L Axial foot TN NPT ø20 to ø100 to “How to Order” in Best
Type Pneumatics No. 2.
F Rod side flange M5 x 0.8 ø20, ø25
N Rubber cushion TF Note 2) Not available for rubber cushion
G Head side flange G ø32 to ø100
type.
A Air cushion
U∗ Rod side trunnion Air cushion Note 3) XC10 and XC11 are not applicable
T∗ Head side trunnion M5 x 0.8 ø20, ø25 to XC85.
Nil
D Clevis
Bore size Rc ø32 to ø100
∗ Not available for ø80 or ø100. M5 x 0.8 ø20, ø25
Note) Mounting brackets are shipped 20 20 mm 50 50 mm TN
NPT ø32 to ø100
together, (but not assembled). 25 25 mm 63 63 mm
M5 x 0.8 ø20, ø25
32 32 mm 80 80 mm TF
G ø32 to ø100
40 40 mm 100 100 mm

Cylinder stroke (mm)


Standard stroke Note 1) Long stroke Note 2)
Bore size (mm)
(mm) (mm)

20 25, 50, 75, 100, 125, 150, 200 201 to 350


25 301 to 400
32 301 to 450
40 25, 50, 75, 100, 125, 150, 200, 301 to 800
250, 300
50, 63 301 to 1200
80 301 to 1400
100 301 to 1500
Note 1) Manufacture of intermediate strokes at 1 mm intervals is possible. (Spacers are
not used.)
Note 2) Long stroke is compatible with the axial foot and rod side flange types. When
other mounting brackets are used or the long stroke exceeds the limit, the
allowable maximum stroke length is determined using the stroke selection table
(Best Pneumatics No. 2).

All other specifications are the same as the standard products Series CG1.
For details, refer to the WEB catalog or Best Pneumatics No. 2.

Refer to page 69 for applicable auto switches.

55
ATEX Compliant
Air Cylinder/Standard type: Double acting, Double rod

Series 55-CG1W
ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100
95°C (T5) Ta –10°C to 40°C
II 2GDc 115°C (T4) Ta 40°C to 60°C

How to Order

Without magnet 55 CG1 W L N 25 100 XC85


With magnet 55 CDG1W L N 25 100 XC85
ATEX category 2
Made to Order
Nil Standard
Built-in magnet for auto switch XC85 Food grade grease

Double Acting/Double Rod

Port thread type


Mounting Rubber cushion
B Basic Nil Rc ø20 to ø100
L Axial foot Type TN NPT ø20 to ø100
F Flange N Rubber cushion M5 x 0.8 ø20, ø25
TF
U∗ Centre trunnion A Air cushion G ø32 to ø100
∗ Not available for bore size ø80 Air cushion
and ø100. M5 x 0.8 ø20, ø25
Note) Mounting brackets are shipped Nil
together, (but not assembled).
Bore size Rc ø32 to ø100
20 20 mm 50 50 mm M5 x 0.8 ø20, ø25
TN
25 25 mm 63 63 mm NPT ø32 to ø100
32 32 mm 80 80 mm M5 x 0.8 ø20, ø25
TF
40 40 mm 100 100 mm G ø32 to ø100

Cylinder stroke (mm)


Bore size (mm) Standard stroke Note 1) (mm) Long stroke (mm)
20 25, 50, 75, 100, 125, 150, 200 201 to 350
25 301 to 400
32 301 to 450
40 25, 50, 75, 100, 125, 150, 200 301 to 800
250, 300
50, 63 301 to 1200
80 301 to 1400
100 301 to 1500
Note 1) Manufacture of intermediate strokes at 1 mm intervals is possible. (Spacers are
not used.)
Note 2) Long stroke is compatible with the axial foot and rod side flange types. When
other mounting brackets are used or the long stroke exceeds the limit, the
allowable maximum stroke length is determined using the stroke selection table
(Best Pneumatics No. 2).

All other specifications are the same as the standard products Series CG1W.
For details, refer to the WEB catalog or Best Pneumatics No. 2.

Refer to page 69 for applicable auto switches.

56
ATEX Compliant
Air Cylinder/Standard type: Non-lube

Series
Non-lube type
55-CS1
: ø125, ø140, ø160, ø180, ø200, ø250, ø300
95°C (T5) Ta 0°C to 40°C
II 2GDc 115°C (T4) Ta 40°C to 60°C

How to Order

55 CS1 L N 160 300


ATEX category 2

Mounting Cushion
B Basic N Without cushion

Cushion
L Foot R With cushion in rod side
F Rod side flange H With cushion in head side
G Head side flange Nil With cushion in both sides
C Single clevis ∗ If specifying more than one symbol, indicate
D Double clevis them alphabetically.
T Centre trunnion

Tubing material
Bore size Stroke range
Symbol Tubing material
(mm) (mm)
125, 140 1000 or less Bore size
Aluminum Non-lube type
160 1200 or less
Nil 125, 140 1001 or more 125 125 mm
160 Steel 1201 or more 140 140 mm
180 to 300 All strokes 160 160 mm
125, 140 1000 or less 180 180 mm
F Steel 200 200 mm
160 1200 or less
250 250 mm
300 300 mm

Type
N Non-lube type

Cylinder stroke (mm) Class 2 Pressure Vessel


Tubing material Aluminum Steel The cylinder with a stroke exceeding
the level shown below that is applicable
Mounting Basic, to the Class 2 Pressure Vessel Act
bracket Basic, Head side flange, Head side flange, cannot be installed or used in Japan.
Single clevis, Double clevis, Single clevis, Foot
Centre trunnion, Foot, Rod side flange Bore size Cylinder stroke
Bore Double clevis, (mm) (mm)
Rod side flange Centre trunnion
size
200 998
125 1000 or less 1000 or less 1600 or less
250 813
140 1000 or less 1200 or less 1600 or less
300 564
160 1200 or less 1200 or less 1600 or less
180 — 1200 or less 2000 or less
200 — 1200 or less 2000 or less
250 — 1200 or less 2400 or less
300 — 1200 or less 2400 or less

All other specifications are the same as the standard products Series CS1.
For details, refer to the WEB catalog or Best Pneumatics No. 2.

Refer to page 69 for applicable auto switches.

57
ATEX Compliant
Air cylinder

Series 55-CDS1
ø125, ø140, ø160, ø180, ø200
95°C (T5) Ta 0°C to 40°C
II 2GDc 115°C (T4) Ta 40°C to 60°C

How to Order

With magnet 55 CDS1 L N 160 300


ATEX category 2

Built-in magnet for auto switch Cushion


N Without cushion
R With cushion in rod side
Mounting Cushion
H With cushion in head side
B Basic Nil With cushion in both sides
L Foot Type ∗ If specifying more than one symbol, indicate them alphabeti-
F Rod side flange N Non-lube type cally.
G Head side flange
C Single clevis
D Double clevis
T Centre trunnion
Bore size
Non-lube type
125 125 mm
140 140 mm
160 160 mm
180 180 mm
200 200 mm

Cylinder stroke (mm) Class 2 Pressure Vessel


The cylinder with a stroke exceeding
Maximum Stroke
the level shown below that is applicable
Bore size to the Class 2 Pressure Vessel Act
(mm) Basic, Head side flange, Single clevis, Foot,
Double clevis, Centre trunnion Rod side flange cannot be installed or used in Japan.
Bore size Cylinder stroke
125, 140 1000 or less 1400 or less
(mm) (mm)
160 1200 or less 1400 or less
200 998
180 1200 or less 1500 or less
200 1200 or less 1200 or less

All other specifications are the same as the standard products Series CS1.
For details, refer to the WEB catalog or Best Pneumatics No. 2.

Refer to page 69 for applicable auto switches.

58
ATEX Compliant
Air Cylinder: Double Rod Type

Series
Non-lube type:
55-CS1W
ø125, ø140, ø160, ø180, ø200, ø250, ø300
95°C (T5) Ta 0°C to 40°C
II 2GDc 115°C (T4) Ta 40°C to 60°C

How to Order

Without magnet 55 CS1 W L N 125 100


With magnet 55 CDS1W L N 125 100
ATEX category 2 Cushion
N Without cushion
Cushion
R With cushion in rod side
Built-in magnet for auto switch H With cushion in head side
Nil With cushion in both sides
∗ If specifying more than one symbol, indicate
Double rod them alphabetically.

Mounting
B Basic
L Foot
Bore size
F Rod side flange
Non-lube type
T Centre trunnion
125 125 mm
140 140 mm
160 160 mm
Tubing material
180 180 mm
Symbol Bore size Tubing material 200 200 mm
(mm)
250∗ 250 mm
125, 140 300∗ 300 mm
Aluminum
160 ∗ It is not available
Nil 180 with auto switch.
200 Steel
250, 300 Type
125, 140 N
F Steel Non-lube type
160

Cylinder stroke (mm) Class 2 Pressure Vessel


The cylinder with a stroke exceeding
Aluminum Steel
Tubing material the level shown below that is applicable
Without magnet With magnet Without magnet to the Class 2 Pressure Vessel Act
Mounting cannot be installed or used in Japan.
Bore Basic, Foot, Rod side flange, Centre trunnion
bracket Bore size Cylinder stroke
size (mm)
(mm) (mm)
125, 140 1000 or less 1000 or less 1000 or less
200 998
160 1200 or less 1200 or less 1200 or less
250 813
180 — 1200 or less 1200 or less
300 564
200 — 1200 or less 1200 or less
250, 300 — — 1200 or less

All other specifications are the same as the standard products Series CS1W.
For details, refer to the WEB catalog or Best Pneumatics No. 2.

Refer to page 69 for applicable auto switches.

59
ATEX Compliant
Compact Cylinder/Standard type: Double acting, Single rod

Series 55-CQ2
ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100
85°C (T6) Ta –10°C to 40°C
II 2GDc 105°C (T4) Ta 40°C to 60°C

How to Order

Without magnet
ø12 to ø25 55 CQ2 B 20 30 D
Without magnet
ø32 to ø100 55 CQ2 B 32 30 D Z
With magnet 55 CDQ2 B 32 30 D Z
Made to Order
ATEX category 2
Nil Standard
With magnet XC85 With food grade grease
(Built-in magnet)

Mounting bracket Auto switch mounting groove


B Through-hole (Standard) ø12 to ø25 2 surfaces
Z
A Both ends tapped ø32 to ø100 4 surfaces
L Foot
F Rod side flange Body option
G Head side flange
Nil Standard (Rod end female thread)
D Double clevis
C With rubber bumper
∗ Mounting brackets are shipped M Rod end male thread
together, (but not assembled).
∗ Cylinder mounting bolts are not ∗ Combination of body options (CM) is
included. available.

Bore size Action


12 12 mm D Double acting
16 16 mm
20 20 mm
Cylinder stroke (mm)
25 25 mm
Bore size Standard stroke
32 32 mm
40 40 mm 12, 16 5, 10, 15, 20, 25, 30
50 50 mm 20, 25 5, 10, 15, 20, 25, 30, 35, 40, 45, 50
63 63 mm 32, 40 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100
80 80 mm 50 to 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100
Note) For intermediate strokes, refer to the standard products Series CQ2.
100 100 mm

Port thread type


M thread ø12 to ø25
Nil
Rc
ø32 to ø100
TF G
∗ For cylinders without magnet, M threads
are compatible only with ø32-5 mm stroke.

All other specifications are the same as the standard products Series CQ2.
For details, refer to the WEB catalog or Best Pneumatics No. 2.

Refer to page 69 for applicable auto switches.

60
ATEX Compliant
Compact Cylinder/Standard type: Double Acting, Double Rod

Series 55-CQ2W
ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100
85°C (T6) Ta –10°C to 40°C
II 2GDc 105°C (T4) Ta 40°C to 60°C

How to Order

Without magnet
ø12 to ø25 55 CQ2W B 20 30 D
Without magnet
ø32 to ø100 55 CQ2W B 32 30 D Z
With magnet 55 CDQ2W B 32 30 D Z
Made to Order
ATEX category 2
Nil Standard
With magnet XC85 With food grade grease
(Built-in magnet)

Auto switch mounting groove


Mounting bracket
ø12 to ø25 2 surfaces
B Through-hole (Standard) Z
ø32 to ø100 4 surfaces
A Both ends tapped
L Foot
F Flange Body option
∗ Mounting brackets are shipped Nil Standard (Rod end female thread)
together, (but not assembled). C With rubber bumper
∗ Cylinder mounting bolts are not M Rod end male thread
included.
∗ Combination of body options (CM) is available.

Bore size Action


12 12 mm
D Double acting
16 16 mm
20 20 mm
25 25 mm Cylinder stroke (mm)
32 32 mm Bore size Standard stroke
40 40 mm 12, 16 5, 10, 15, 20, 25, 30
50 50 mm 20, 25 5, 10, 15, 20, 25, 30, 35, 40, 45, 50
63 63 mm 32, 40 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100
80 80 mm 50 to 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100
100 100 mm

Port thread type


M thread ø12 to ø25
Nil
Rc
ø32 to ø100
TF G
∗ For cylinders without magnet, M threads
are compatible only with ø32-5 mm stroke.

All other specifications are the same as the standard products Series CQ2.
For details, refer to the WEB catalog or Best Pneumatics No. 2.

Refer to page 69 for applicable auto switches.

61
ATEX Compliant
Compact Cylinder: Long Stroke/Double Acting, Single Rod

Series 55-CQ2
ø32, ø40, ø50, ø63, ø80, ø100
85°C (T6) Ta –10°C to 40°C
II 2GDc 105°C (T4) Ta 40°C to 60°C

How to Order

Without magnet 55 CQ2 A 32 200 DC Z


With magnet 55 CDQ2 A 32 200 DC Z
Made to Order
ATEX category 2
Nil Standard
XC85 With food grade grease
Built-in magnet for auto switch
Auto switch mounting groove
Mounting bracket Z 4 surfaces
A Both ends tapped
L Foot
F Rod side flange Body option
G Head side flange Nil Standard (Rod end female thread)
D Double clevis M Rod end male thread
∗ Mounting brackets are shipped
together, (but not assembled).
Cushion
Bore size C Rubber cushion

32 32 mm
40 40 mm Action
50 50 mm D Double acting
63 63 mm
80 80 mm
100 100 mm Cylinder stroke (mm)
Bore size Standard stroke
Port thread type 32, 40, 50
125, 150, 175, 200, 250, 300
Nil Rc 63, 80, 100
TF G

All other specifications are the same as the standard products Series CQ2.
For details, refer to the WEB catalog or Best Pneumatics No. 2.

Refer to page 69 for applicable auto switches.

62
ATEX Compliant
Compact Cylinder: Large Bore Size/Double Acting, Single Rod

Series 55-CQ2
ø125, ø140, ø160, ø180, ø200
85°C (T6) Ta –10°C to 40°C
II 2GDc 105°C (T4) Ta 40°C to 60°C

How to Order

Without magnet 55 CQ2B 125 30 DC Z


With magnet 55 CDQ2B 125 30 DC Z
Made to Order
ATEX category 2
Nil Standard
XC85 With food grade grease
Built-in magnet for auto switch

Auto switch mounting groove


Mounting bracket
Z 4 surfaces
B Standard (Through-hole/Both ends tapped common)
∗ Cylinder mounting bolts are not included.
Body option
Nil Standard (Rod end female thread)
Bore size
M Rod end male thread
125 125 mm
140 140 mm
160 160 mm Cushion
180 180 mm C Rubber cushion
200 200 mm

Action
Port thread type D Double acting
Nil Rc
TF G
Cylinder stroke (mm)
Bore size Standard stroke
125, 140, 160 10, 20, 30, 40, 50, 75, 100
180, 200 125, 150, 175, 200, 250, 300

All other specifications are the same as the standard products Series CQ2.
For details, refer to the WEB catalog or Best Pneumatics No. 2.

Refer to page 69 for applicable auto switches.

63
ATEX Compliant
Dual Rod Cylinder/Basic Type

Series 55-CXS
ø6, ø10, ø15, ø20, ø25, ø32
65°C (T6) Ta –10°C to 40°C
II 2GDc 85°C (T6) Ta 40°C to 60°C

How to Order

Port thread type


Symbol Type Bore size
M thread ø6 to ø20
Nil
Rc1/8
ø25, ø32
TF G1/8

55 CXS M 20 100
ATEX category 2 Made to Order
Nil Standard
XB11 Long stroke type
Bearing
M Slide bearing
L Ball bushing bearing

Bore size/Standard stroke (mm)


Bore size Standard stroke (mm)
6 10, 20, 30, 40, 50
10, 15, 20, 25, 30, 35, 40, 45,
10
50, 60, 70, 75
15, 20 10, 15, 20, 25, 30, 35, 40, 45,
25, 32 50, 60, 70, 75, 80, 90, 100

All other specifications are the same as the standard products Series CXS.
For details, refer to the WEB catalog or Best Pneumatics No. 3.

Refer to page 69 for applicable auto switches.

64
ATEX Compliant
Dual Rod Cylinder/Double Rod Type

Series 55-CXSW
ø6, ø10, ø15, ø20, ø25, ø32
65°C (T6) Ta –10°C to 40°C
II 2GDc 85°C (T6) Ta 40°C to 60°C

How to Order

Port thread type


Symbol Type Bore size
M thread ø6 to ø20
Nil
Rc1/8
ø25, ø32
TF G1/8

55 CXS W L 20 100
ATEX category 2 Made to Order
Nil Standard
Double rod type XB11 Long stroke type

Bearing
M Slide bearing
L Ball bushing bearing

Bore size/Stroke (mm)


Bore size Standard stroke
6 10, 20, 30, 40, 50
10, 15 10, 20, 30, 40, 50
10, 20, 30, 40, 50,
20, 25, 32 75, 100

All other specifications are the same as the standard products Series CXS.
For details, refer to the WEB catalog or Best Pneumatics No. 3.

Refer to page 69 for applicable auto switches.

65
ATEX Compliant
Mechanically Jointed Rodless Cylinder/Basic Type

Series 55-MY1B
ø10, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100
75°C (T6) Ta 5°C to 40°C
II 2Gc 95°C (T5) Ta 40°C to 60°C

How to Order

Basic 55 MY1B 20 300


ATEX category 2 Basic Made to Order
Nil Standard type
XB11 Long stroke type
Bore size
10 10 mm
16 16 mm Cylinder stroke (mm)
20 20 mm Maximum
Bore size (mm) Standard stroke∗ (mm)
25 25 mm stroke (mm)
32 32 mm 10, 16 100, 200, 300, 400, 500, 600 3000
40 40 mm 20, 25, 32, 40 700, 800, 900, 1000, 1200
1400, 1600, 1800, 2000 5000
50 50 mm 50, 63, 80, 100
63 63 mm ∗ Strokes are manufacturable in 1 mm increments, up to the maximum stroke.
80 80 mm However, when exceeding a 2000 mm stroke, specify “-XB11” at the end of the
model number.
100 100 mm
With strokes of 49 mm or less, the air cushion capacity may decrease and it may
not be possible to mount multiple auto switches.

Port thread type


Symbol Type Bore size
M thread ø10, ø16, ø20
Nil
Rc ø25 ,ø32, ø40,
TN NPT ø50, ø63, ø80,
TF G ø100

Piping
Nil Standard
G Centralized piping type
Note) For ø10, only G is available.

All other specifications are the same as the standard products Series MY1B.
For details, refer to the WEB catalog or Best Pneumatics No. 2.

Refer to page 69 for applicable auto switches.

66
ATEX Compliant
Mechanically Jointed Rodless Cylinder/Slide Bearing Guide Type

Series 55-MY1M
ø16, ø20, ø25, ø32, ø40, ø50, ø63
75°C (T6) Ta 5°C to 40°C
II 2Gc 95°C (T5) Ta 40°C to 60°C

How to Order

Slide bearing guide type 55 MY1M 20 G 300


ATEX category 2 Made to Order
Nil Standard type
XB11 Long stroke type
Slide bearing guide type

Bore size
16 16 mm
20 20 mm
25 25 mm
32 32 mm
40 40 mm
50 50 mm
63 63 mm

Port thread type


Symbol Type Bore size
M thread ø16, ø20
Nil
Rc ø25, ø32,
TN NPT ø40, ø50,
TF G ø63

Piping
Nil Standard
G Centralized piping type

Cylinder stroke (mm)


Bore size Maximum
Standard stroke∗ (mm)
(mm) stroke (mm)

16 3000
100, 200, 300, 400, 500, 600, 700
20, 25, 32 800, 900, 1000, 1200, 1400, 1600
1800, 2000 5000
40, 50, 63
∗ Strokes are manufacturable in 1 mm increments, up to the maximum stroke. However,
when exceeding a 2000 mm stroke, specify “-XB11” at the end of the model number.
With strokes of 49 mm or less, the air cushion capacity may decrease and it may not
be possible to mount multiple auto switches.

All other specifications are the same as the standard products Series MY1M.
For details, refer to the WEB catalog or Best Pneumatics No. 2.

Refer to page 69 for applicable auto switches.

67
ATEX Compliant
Mechanically Jointed Rodless Cylinder/Linear Guide Type

Series 55-MY1H
ø10, ø16, ø20, ø25, ø32, ø40
75°C (T6) Ta 5°C to 40°C
II 2Gc 95°C (T5) Ta 40°C to 60°C

How to Order

Linear guide type 55 MY1H 25 300


ATEX category 2 Made to Order
Nil Standard type
Linear guide type XB10 Intermediate stroke (using exclusive body)
XB11 Long stroke type

Bore size
10 10 mm Cylinder stroke (mm)
16 16 mm Bore size Maximum
Standard stroke∗ (mm)
20 20 mm (mm) stroke (mm)
25 25 mm
10, 16, 20 50, 100, 150, 200, 250, 300 1000
32 32 mm
25, 32, 40 350, 400, 450, 500, 550, 600 1500
40 40 mm
∗ Strokes are manufacturable from 50 mm in 1 mm increments, up to the
maximum stroke. However, add “-XB10” to the end of the part number
for nonstandard strokes from 51 to 599. Also when exceeding a 600 mm
stroke, specify “-XB11” at the end of the model number. (Except ø10)

Port thread type


Symbol Type Bore size
M thread ø10, ø16, ø20
Nil
Rc
TN NPT ø25, ø32, ø40
TF G

Piping
Nil Standard
G Centralized piping type
Note) For ø10, only G is available.
All other specifications are the same as the standard products
Series MY1H. For details, refer to the WEB catalog or Best
Pneumatics No. 2.

Refer to page 69 for applicable auto switches.

Linear guide type 55 MY1H 25 300 X1985


ATEX category 2 Rust proof guide

Linear guide type Cylinder stroke (mm)


Bore size
(mm) Standard stroke∗ (mm)
Bore size 25
50, 100, 150, 200, 250, 300, 350,
25 25 mm 32
400, 450, 500, 550, 600, 750
32 32 mm 40
40 40 mm ∗ X1985 type can only be manufactured with the strokes listed in
table.

Port thread type Piping


Symbol Type Bore size Nil Standard
Nil Rc G Centralized piping type
TN NPT ø25 to ø40
TF G

68
ATEX Compliant Auto Switch Applicable Cylinder List
Model 55- 55- 55- 55- 55- 55- 55- 55- 55- 55- 55- 55- 55- 56- 56- 56- 55-
C76 C85 C95 C96 CP96 C55 CG1 CS1 CQ2(Z) CXS/W MY1B MY1M MY1H CRB1 CRB2 CRBU2 CRQ2
Switch type
Note 1)
D-M9-588            
(20 to 63) (125 to 200) (Except 50)

Note 2)
D-M9V-588          
(125 to 200) (Except 50)

Note 1)
D-M9W-588            
(20 to 63) (125 to 200) (Except 50)

Note 2)
D-M9WV-588          
(125 to 200) (Except 50)

Note 3)
D-H7A2-588   
(20 to 63)

Note 4)
D-F7P-588   
(12 to 160)

Note 4)
D-F7PV-588   
(12 to 160)

D-F5P-588   
(160 to 250) (125 to 200)

D-Y7P-588       
(160 to 200) (125 to 200) (25 to 100) (25 to 63) (25 to 40)

D-Y7PV-588       
(160 to 200) (125 to 200) (25 to 100) (25 to 63) (25 to 40)

D-S7P-588   
(50 to 100) (20 to 40) (20 to 40)

D-S9P-588  
(10, 15) (10, 15)

D-S9PV-588  
(10, 15) (10, 15)

D-F6P-588

Note 3)
D-C73-588 
D-C80-588   (20 to 63)

Note 4)
D-A73-588 
D-A80-588   (12 to 160)

Note 4)
D-A73H-588 
D-A80H-588   (12 to 160)

D-A54-588  
D-A67-588 (160 to 250)
 (125 to 200)

D-A90-588     
D-A93-588  (16 to 25)
   (20 to 63) (125 to 200)
 (10 to 20) (16, 20)
 
Note 5)
D-A90V-588   
D-A93V-588     (125 to 200)
 (10 to 20) (16, 20)
 

D-90A-588   
D-93A-588 (125 to 200) (10, 15) (10, 15)

D-Z73-588     
D-Z80-588 (160 to 200)
 (125 to 200)
 (25 to 100) (25 to 63) (25 to 40)

D-E73A-588
D-E80A-588

D-R73-588   
D-R80-588 (50 to 100) (20 to 40) (20 to 40)

∗ ( ): Cylinder size
Note 1) 55-C85 Band mounting all sizes, and Rail mounting for 8 to 16 only.
Note 2) 55-C85 Band mounting only.
Note 3) 55-C85 Rail mounting only.
Note 4) 55-C85 Rail mounting only. 69
Note 5) 55-C85 Rail mounting only, for 16 to 25 only.
ATEX Compliant
Solid State Switch/Direct Mounting
D-M9N(V)·D-M9P(V)·D-M9B(V)-588
II 3G Ex nA II T5 X –10°C ≤ Ta ≤ +60°C Auto Switch Specifications
II 3D Ex tD A22 IP67 T93°C X
PLC: Programmable Logic Controller
D-M9/D-M9V (With indicator light)
Auto switch part no. D-M9N D-M9NV D-M9P D-M9PV D-M9B D-M9BV
Grommet Electrical entry direction In-line Perpendicular In-line Perpendicular In-line Perpendicular
Wiring type 3-wire 2-wire
Output type NPN PNP —
Applicable load IC circuit, Relay, PLC 24 VDC relay, PLC
Power supply 5/12/24 VDC (4.5 to 28 V) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28V)
Load current 40 mA or less 2.5 to 40 mA
Internal voltage drop 0.8 V or less at 10 mA (2 V or less at 40 mA) 4 V or less
Leakage current 100 µA or less at 24 VDC 0.8 mA or less
Indicator light Red LED illuminates when turned ON.
Standard CE marking
 This category 3 type auto switch can only be used in zones 2 and 22.

Oilproof Heavy-duty Lead Wire Specifications


Auto switch model D-M9N D-M9P D-M9B
Sheath Outside diameter [mm] 2.7 x 3.2 (ellipse)
Number of cores 3 cores (Brown/Blue/Black) 2 cores (Brown/Blue)
Insulator
Outside diameter [mm] ø0.9
Cross section [mm2] 0.15
Conductor
Strand diameter [mm] ø0.05
Minimum bending radius [mm] (Reference) 20

How to Order

D M9 N V L 588
Auto switch part no. ATEX category 3

Wiring and output


N 3-wire NPN
P 3-wire PNP
B 2-wire

Electrical entry direction


Nil In-line
V Perpendicular

Lead wire length


Nil 0.5 m
L 3m
Z 5m
SAPC 0.5 m + M8 - 3 pins pre-wired connector
MAPC 1 m + M8 - 3 pins pre-wired connector
SBPC 0.5 m + M8 - 4 pins pre-wired connector
MBPC 1 m + M8 - 4 pins pre-wired connector
SDPC 0.5 m + M12 - 4 pins pre-wired connector
MDPC 1 m + M12 - 4 pins pre-wired connector

Connector Specifications
Connector type M8 - 3 pins M8 - 4 pins M12 - 4 pins
1 4 1 2

Pin 2 1
arrangement
3 4
3 3 4

70
ATEX Compliant
2-Colour Solid State Switch/Direct Mounting
D-M9NW(V)·D-M9PW(V)·D-M9BW(V)-588 RoHS

II 3G Ex nA II T5 X –10°C ≤ Ta ≤ +60°C Auto Switch Specifications


II 3D Ex tD A22 IP67 T93°C X
PLC: Programmable Logic Controller
D-M9W/D-M9WV (With 2 colour indicator light)
Auto switch part no. D-M9NW D-M9NWV D-M9PW D-M9PWV D-M9BW D-M9BWV
Grommet Electrical entry direction In-line Perpendicular In-line Perpendicular In-line Perpendicular
Wiring type 3-wire 2-wire
Output type NPN PNP —
Applicable load IC circuit, Relay, PLC 24 VDC relay, PLC
Power supply 5/12/24 VDC (4.5 to 28 V) —
Current consumption 10 mA or less —
Load voltage 28 VDC or less — 24 VDC (10 to 28V)
Load current 40 mA or less 2.5 to 40 mA
Internal voltage drop 0.8 V or less at 10 mA (2 V or less at 40 mA) 4 V or less
Leakage current 100 µA or less at 24 VDC 0.8 mA or less
Operating position .................... Red LED illuminates.
Indicator light
Optimum operating position ...... Green LED illuminates.
Standard CE marking
 This category 3 type auto switch can only be used in zones 2 and 22.

Oilproof Flexible Heavy-duty Lead Wire Specifications


Auto switch model D-M9NW D-M9PW D-M9BW
Sheath Outside diameter [mm] 2.7 x 3.2 (ellipse)
Number of cores 3 cores (Brown/Blue/Black) 2 cores (Brown/Blue)
Insulator
Outside diameter [mm] ø0.9
Cross section [mm2] 0.15
Conductor
Strand diameter [mm] ø0.05
Minimum bending radius [mm] (Reference) 20

How to Order

D M9 N W V L 588
Auto switch part no. ATEX category 3

Wiring and output


N 3-wire NPN
P 3-wire PNP 2 colour display
B 2-wire
Electrical entry direction
Nil In-line
V Perpendicular

Lead wire length


Nil 0.5 m
M 1m
L 3m
Z 5m
SAPC 0.5 m + M8 - 3 pins pre-wired connector
MAPC 1 m + M8 - 3 pins pre-wired connector
SBPC 0.5 m + M8 - 4 pins pre-wired connector
MBPC 1 m + M8 - 4 pins pre-wired connector
SDPC 0.5 m + M12 - 4 pins pre-wired connector
MDPC 1 m + M12 - 4 pins pre-wired connector

Connector Specifications
Connector type M8 - 3 pins M8 - 4 pins M12 - 4 pins

1 4 1 2

Pin 2 1
arrangement
3 4
3 3 4

71
ATEX Compliant
Solid State Switch/Band Mounting
D-H7A2-588
II 3G Ex nA II T5 X -10°C ≤ Ta ≤ +60°C Auto Switch Specifications
II 3D Ex tD A22 IP67 T93°C X
PLC: Programmable Logic Controller
D-H7 A2 (With indicator light)
Auto switch part no. D-H7A2
Grommet Wiring type 3-wire
Output type PNP
Applicable load IC circuit/Relay/PLC
Power supply 5/12/24 VDC (4.5 to 28 VDC)
Current consumption 10 mA or less
Load current 80 mA or less
Internal voltage drop 0.8 V or less
Leakage current 100 µA or less at 24 VDC
Indicator light Red LED illuminates when turned ON.
Standard CE marking
 This category 3 type auto switch can only be used in zones 2 and 22.

Oilproof Heavy-duty Lead Wire Specifications


Auto switch model D-H7A2
Sheath Outside diameter [mm] ø3.4
Number of cores 3 cores (Brown/Blue/Black)
Insulator
Outside diameter [mm] ø1.1
Cross section [mm2] 0.2
Conductor
Strand diameter [mm] ø0.08
Minimum bending radius [mm] (Reference) 21

How to Order

D H7A2 588
Auto switch part no. ATEX category 3

Lead wire length


Nil 0.5 m
L 3m
Z 5m
SAPC 0.5 m + M8 - 3 pins pre-wired connector
MAPC 1 m + M8 - 3 pins pre-wired connector
SBPC 0.5 m + M8 - 4 pins pre-wired connector
MBPC 1 m + M8 - 4 pins pre-wired connector
SDPC 0.5 m + M12 - 4 pins pre-wired connector
MDPC 1 m + M12 - 4 pins pre-wired connector

Connector Specifications
Connector type M8 - 3 pins M8 - 4 pins M12 - 4 pins
1 4 1 2

2 1
Pin
arrangement
3 4
3 3 4

72
ATEX Compliant
Solid State Switch/Rail Mounting
D-F7P(V)-588
II 3G Ex nA II T5 X -10°C ≤ Ta ≤ +60°C Auto Switch Specifications
II 3D Ex tD A22 IP67 T93°C X
PLC: Programmable Logic Controller
D-F7P, D-F7PV (With indicator light)
Auto switch part no. D-F7P D-F7PV
Grommet Wiring type 3-wire
Output type PNP
Applicable load IC circuit/Relay/PLC
Power supply 5/12/24 VDC (4.5 to 28 VDC)
Current consumption 10 mA or less
Load current 80 mA or less
Internal voltage drop 0.8 V or less
Leakage current 100 µA or less at 24 VDC
Indicator light Red LED illuminates when turned ON.
Standard CE marking
 This category 3 type auto switch can only be used in zones 2 and 22.

Oilproof Heavy-duty Lead Wire Specifications


Auto switch model D-F7P
Sheath Outside diameter [mm] ø3.4
Number of cores 3 cores (Brown/Blue/Black)
Insulator
Outside diameter [mm] ø1.1
Cross section [mm2] 0.2
Conductor
Strand diameter [mm] ø0.08
Minimum bending radius [mm] (Reference) 21

How to Order

D F7P 588
Auto switch part no. ATEX category 3

Electrical entry direction


Nil In-line
V Perpendicular

Lead wire length


Nil 0.5 m
L 3m
Z 5m
SAPC 0.5 m + M8 - 3 pins pre-wired connector
MAPC 1 m + M8 - 3 pins pre-wired connector
SBPC 0.5 m + M8 - 4 pins pre-wired connector
MBPC 1 m + M8 - 4 pins pre-wired connector
SDPC 0.5 m + M12 - 4 pins pre-wired connector
MDPC 1 m + M12 - 4 pins pre-wired connector

Connector Specifications
Connector type M8 - 3 pins M8 - 4 pins M12 - 4 pins
1 4 1 2

2 1
Pin
arrangement 3 4
3 3 4

73
ATEX Compliant
Solid State Switch/Tie-rod Mounting
D-F5P-588
II 3G Ex nA II T5 X -10°C ≤ Ta ≤ +60°C Auto Switch Specifications
II 3D Ex tD A22 IP67 T93°C X
PLC: Programmable Logic Controller
D-F5P (With indicator light)
Auto switch part no. D-F5P
Grommet Wiring type 3-wire
Output type PNP
Applicable load IC circuit/Relay/PLC
Power supply 5/12/24 VDC (4.5 to 28 VDC)
Current consumption 10 mA or less
Load current 80 mA or less
Internal voltage drop 0.8 V or less
Leakage current 100 µA or less at 24 VDC
Indicator light Red LED illuminates when turned ON.
Standard CE marking
 This category 3 type auto switch can only be used in zones 2 and 22.

Oilproof Heavy-duty Lead Wire Specifications


Auto switch model D-F5P
Sheath Outside diameter [mm] ø4
Number of cores 3 cores (Brown/Blue/Black)
Insulator
Outside diameter [mm] ø1.22
Cross section [mm2] 0.3
Conductor
Strand diameter [mm] ø0.08
Minimum bending radius [mm] (Reference) 24

How to Order

D F5P 588
Auto switch part no. ATEX category 3

Lead wire length


Nil 0.5 m
L 3m
Z 5m
SAPC 0.5 m + M8 - 3 pins pre-wired connector
MAPC 1 m + M8 - 3 pins pre-wired connector
SBPC 0.5 m + M8 - 4 pins pre-wired connector
MBPC 1 m + M8 - 4 pins pre-wired connector
SDPC 0.5 m + M12 - 4 pins pre-wired connector
MDPC 1 m + M12 - 4 pins pre-wired connector

Connector Specifications
Connector type M8 - 3 pins M8 - 4 pins M12 - 4 pins
1 4 1 2

2 1
Pin
arrangement 3 4
3 3 4

74
ATEX Compliant
Solid State Switch/Direct Mounting
D-Y7P(V)-588
II 3G Ex nA II T5 X -10°C ≤ Ta ≤ +60°C Auto Switch Specifications
II 3D Ex tD A22 IP67 T93°C X
PLC: Programmable Logic Controller
D-Y7P/D-Y7PV (With indicator light)
Auto switch part no. D-Y7P D-Y7PV
Grommet Electrical entry direction In-line Perpendicular
Wiring type 3-wire
Output type PNP
Applicable load IC circuit/Relay/PLC
Power supply 5/12/24 VDC (4.5 to 28 VDC)
Current consumption 10 mA or less
Load current 80 mA or less
Internal voltage drop 0.8 V or less
Leakage current 100 µA or less at 24 VDC
Indicator light Red LED illuminates when turned ON.
Standard CE marking
 This category 3 type auto switch can only be used in zones 2 and 22.

Oilproof Flexible Heavy-duty Lead Wire Specifications


Auto switch model D-Y7P
Sheath Outside diameter [mm] ø3.4
Number of cores 3 cores (Brown/Blue/Black)
Insulator
Outside diameter [mm] ø1.0
Cross section [mm2] 0.15
Conductor
Strand diameter [mm] ø0.05
Minimum bending radius [mm] (Reference) 21

How to Order

D Y7P 588
Auto switch part no. ATEX category 3

Electrical entry direction


Nil In-line
V Perpendicular

Lead wire length


Nil 0.5 m
L 3m
Z 5m
SAPC 0.5 m + M8 - 3 pins pre-wired connector
MAPC 1 m + M8 - 3 pins pre-wired connector
SBPC 0.5 m + M8 - 4 pins pre-wired connector
MBPC 1 m + M8 - 4 pins pre-wired connector
SDPC 0.5m + M12 - 4 pins pre-wired connector
MDPC 1m + M12 - 4 pins pre-wired connector

Connector Specifications
Connector type M8 - 3 pins M8 - 4 pins M12 - 4 pins
1 4 1 2

2 1
Pin
arrangement 3 4
3 3 4

75
ATEX Compliant
Solid State Switch/Direct Mounting
D-S7P-588
II 3G Ex nA II T5 X -10°C ≤ Ta ≤ +60°C Auto Switch Specifications
II 3D Ex tD A22 IP67 T93°C X
PLC: Programmable Logic Controller
D-S7P1/D-S7P2 (With indicator light)
Auto switch part no. D-S7P1 D-S7P2
Grommet/Connector Wiring type 3-wire
Electrical entry: In-line Output type PNP
Applicable load IC circuit/Relay/PLC
Power supply 5/12/24 VDC (4.5 to 28 VDC)
Current consumption 10 mA or less
Load current 80 mA or less
Internal voltage drop 0.8 V or less
Leakage current 100 µA or less at 24 VDC
Indicator light Red LED illuminates when turned ON.
Standard CE marking
 This category 3 type auto switch can only be used in zones 2 and 22.

Oilproof Heavy-duty Lead Wire Specifications


Auto switch model D-S7P
Sheath Outside diameter [mm] ø3.4
Number of cores 3 cores (Brown/Blue/Black)
Insulator
Outside diameter [mm] ø1.1
D-S7P2 D-S7P1 Cross section [mm2] 0.2
Conductor
Strand diameter [mm] ø0.08
Minimum bending radius [mm] (Reference) 21

How to Order
Left hand mounting Right hand mounting

D S7P 588
Auto switch part no. ATEX category 3

Mounting
1 Right hand mounting
2 Left hand mounting

Lead wire length


Nil 0.5 m
L 3m
Z 5m
SAPC 0.5 m + M8 - 3 pins pre-wired connector
MAPC 1 m + M8 - 3 pins pre-wired connector
SBPC 0.5 m + M8 - 4 pins pre-wired connector
MBPC 1m + M8 - 4 pins pre-wired connector
SDPC 0.5 m + M12 - 4 pins pre-wired connector
MDPC 1 m + M12 - 4 pins pre-wired connector

Connector Specifications
Connector type M8 - 3 pins M8 - 4 pins M12 - 4 pins
1 4 1 2

2 1
Pin
arrangement 3 4
3 3 4

76
ATEX Compliant
Solid State Switch/Direct Mounting
D-S9P(V)-588
II 3G Ex nA II T5 X -10°C ≤ Ta ≤ +60°C Auto Switch Specifications
II 3D Ex tD A22 IP67 T93°C X
PLC: Programmable Logic Controller
D-S9P/D-S9PV (With indicator light)
D-S9P1 D-S9PV1
Auto switch part no.
Grommet D-S9P2 D-S9PV2
Electrical entry direction In-line Perpendicular
Wiring type 3-wire
Output type PNP
Applicable load IC circuit/Relay/PLC
Power supply 5/12/24 VDC (4.5 to 28 VDC)
Current consumption 10 mA or less
Load current 80 mA or less
Internal voltage drop 0.8 V or less
Leakage current 100 µA or less at 24 VDC
Indicator light Red LED illuminates when turned ON.
Standard CE marking
 This category 3 type auto switch can only be used in zones 2 and 22.

Oilproof Heavy-duty Lead Wire Specifications


Auto switch model D-S9P
D-S9P1 D-S9P2 Sheath Outside diameter [mm] ø3.4
Number of cores 3 cores (Brown/Blue/Black)
Insulator
Outside diameter [mm] ø1.1
Cross section [mm2] 0.2
Conductor
Strand diameter [mm] ø0.08
Minimum bending radius [mm] (Reference) 21
Left hand mounting Right hand mounting
D-S9PV1 D-S9PV2
How to Order

Left hand mounting Right hand mounting


D S9P 588
Auto switch part no. ATEX category 3

Electrical entry direction


Nil In-line
V Perpendicular

Mounting
1 Right hand mounting
2 Left hand mounting

Lead wire length


Nil 0.5 m
L 3m
Z 5m
SAPC 0.5 m + M8 - 3 pins pre-wired connector
MAPC 1 m + M8 - 3 pins pre-wired connector
SBPC 0.5 m + M8 - 4 pins pre-wired connector
MBPC 1 m + M8 - 4 pins pre-wired connector
SDPC 0.5 m + M12 - 4 pins pre-wired connector
MDPC 1 m + M12 - 4 pins pre-wired connector

Connector Specifications
Connector type M8 - 3 pins M8 - 4 pins M12 - 4 pins
1 4 1 2

2 1
Pin
arrangement 3 4
3 3 4

77
ATEX Compliant
Solid State Switch for Hygienic Design Cylinder/Direct Mounting
D-F6P-588
II 3G Ex nA II T5 X -10°C ≤ Ta ≤ +60°C Auto Switch Specifications
II 3D Ex tD A22 IP67 T93°C X
PLC: Programmable Logic Controller
D-F6P (With indicator light)
Auto switch part no. D-F6P
Grommet Electrical entry direction In-line
Wiring type 3-wire
Output type PNP
Applicable load IC circuit, Relay, PLC
Power supply 5/12/24 VDC (4.5 to 28 V)
Current consumption 10 mA or less
Load current 40 mA or less
Internal voltage drop 0.8 V or less
Leakage current 100 µA or less at 24 VDC
Indicator light Red LED illuminates when turned ON.
Standard CE marking
 This category 3 type auto switch can only be used in zones 2 and 22.

Oilproof Flexible Heavy-duty Lead Wire Specifications


Auto switch model D-F6P
Sheath Outside diameter [mm] 2.7 x 3.2 (ellipse)
Number of cores 3 cores (Brown/Blue/Black)
Insulator
Outside diameter [mm] ø0.9
Cross section [mm2] 0.15
Conductor
Strand diameter [mm] ø0.05
Minimum bending radius [mm] (Reference) 20

How to Order

D F6P 588
Auto switch part no. ATEX category 3

Lead wire length


Nil 0.5 m
L 3m
Z 5m
SAPC 0.5 m + M8 - 3 pins pre-wired connector
MAPC 1 m + M8 - 3 pins pre-wired connector
SBPC 0.5 m + M8 - 4 pins pre-wired connector
MBPC 1 m + M8 - 4 pins pre-wired connector
SDPC 0.5 m+ M12 - 4 pins pre-wired connector
MDPC 1 m+ M12 - 4 pins pre-wired connector

Connector Specifications
Connector type M8 - 3 pins M8 - 4 pins M12 - 4 pins
1 4 1 2

2 1
Pin
arrangement 3 4
3 3 4

78
Prior to Use
Auto Switch/Internal Circuit
Reed Auto Switch

No. q w e r
2-wire (Reed switch) 2-wire (Reed switch) 2-wire (Reed switch) 2-wire (Reed switch)
Internal Circuit

Brown Brown Brown Brown


protection circuit

protection circuit

protection box
protection box
Indicator Load Load Indicator Load Load

Contact
circuit circuit

Contact
Contact

Contact
Blue Blue Blue Blue

No. t y u
3-wire (Reed switch, NPN) 2-wire (Reed switch) 2-wire (Reed switch)
Internal Circuit

Brown Brown Brown


Black
protection circuit

Indicator 2-color

protection box
Load 2-color Load
circuit indicator indicator

Contact
Contact

Load circuit circuit


Blue Blue Blue

Contact Protection Box: CD-P12


<Applicable switch models> Contact Protection Box Specifications
D-A73/A8, D-A73H/A80H, D-C73/C8, D-E73A/E80A, D-Z73/Z8, 9A,
Part no. CD-P12
and D-A9/A9V type
Load voltage 24 VDC
The auto switches above do not have a built-in contact protection circuit.
A contact protection box is not required for solid state auto switches due Max. load current 50 mA
to their construction. ∗ Lead wire length — Auto switch connection side 0.5 m
Load connection side 0.5 m
q Where the operation load is an inductive load.
w Where the wiring length to load is greater than 5 m. Contact Protection Box Internal Circuit
Therefore, use a contact protection box with the switch for any of CD-P12 Brown Brown(+)
the above cases: Choke coil
Zener
The contact life may be shortened (due to permanent energizing Auto switch side Load side
diode
conditions.) Blue Blue(−)

Even for the built-in contact protection circuit type (D-A54), use the
contact protection box when the wiring length to load is very long Contact Protection Box/Dimensions
(over 30 m) and PLC (Programmable Logic Controller) with a large
inrush current is used.

Contact Protection Box Connection


To connect a switch unit to a contact protection box, connect the lead wire from the side of the contact protection box marked SWITCH to the lead wire
coming out of the switch unit. Keep the switch as close as possible to the contact protection box, with a lead wire length of no more than 1 meter.

79
ATEX Compliant
Reed Switch/Band Mounting
D-C73/D-C80-588
II 3G Ex nA II T5 X -10°C�≤�Ta�≤�+60°C Auto Switch Specifications
II 3D Ex tD A22 IP67 T93°C X
PLC: Programmable Logic Controller
D-C7 (With indicator light)
Auto switch model number D-C73
Grommet Applicable load Relay/PLC
Load voltage 24 VDC
Max. load current and range 5 to 40 mA
Internal Circuit ∗ e
Contact protection circuit None
Internal voltage drop 2.4 V or less
Indicator light Red LED illuminates when turned ON
Standards CE marking
D-C8 (Without indicator light)
Auto switch model number D-C80
Applicable load Relay/PLC/IC circuit
AC AC
Load voltage 24 V or less 48 V
DC DC
Max. load current 50 mA 40 mA
Internal Circuit ∗ r
Contact protection circuit None
Internal resistance 1 Ω or less (Including 3 m lead wire)
Standards CE marking

Oilproof Heavy-duty Lead Wire Specifications


Auto switch type D-C73/D-C80
Sheath Outside diameter [mm] ø3.4
Number of cores 2 cores (Brown, Blue)
Insulator
Outside diameter [mm] ø1.1
Cross section [mm2] 0.2
Conductor [mm]
Strand diameter [mm] ø0.08
Minimum bending radius of lead wire [mm] (Reference) 21
∗ For internal circuit, refer to the Internal Circuit No. on page 79.
This category 3 type auto switch can only be used in zones 2 and 22.

How to Order

D C 588
ATEX category 3

Auto switch model number Lead wire length


73 With indicator light Nil 0.5 m
80 Without indicator light L 3m
Z 5 m (Except D-C80)

80
ATEX Compliant
Reed Switch/Rail Mounting
D-A73(H)/D-A80(H)-588
II 3G Ex nA II T5 X -10°C�≤�Ta�≤�+60°C Auto Switch Specifications
II 3D Ex tD A22 IP67 T93°C X
PLC: Programmable Logic Controller
D-A73, D-A73H (With indicator light)
Auto switch model number D-A73/D-A73H
Grommet Applicable load Relay/PLC
Electrical entry: Perpendicular Load voltage 24 VDC
Load current range 5 to 40 mA
Internal Circuit ∗ e
Contact protection circuit None
Internal voltage drop 2.4 V or less
Indicator light Red LED illuminates when turned ON
Standard CE marking
D-A80, D-A80H (Without indicator light)
Auto switch model number D-A80/D-A80H
Applicable load Relay/IC circuit/PLC
AC AC
Load voltage 24 V or less 48 V
DC DC

Max. load current 50 mA 40 mA


Internal Circuit ∗ r
Contact protection circuit None
Internal resistance 1 Ω or less (Including 3 m lead wire)
Standard CE marking

Oilproof Heavy-duty Lead Wire Specifications


Auto switch type D-A73/D-A73H/D-A80/D-A80H
Sheath Outside diameter [mm] ø3.4
Number of cores 2 cores (Brown, Blue)
Insulator
Outside diameter [mm] ø1.1
Cross section [mm2] 0.2
Conductor
Strand diameter [mm] ø0.08
Minimum bending radius of lead wire [mm] (Reference) 21
∗ For internal circuit, refer to the Internal Circuit No. on page 79.
This category 3 type auto switch can only be used in zones 2 and 22.

How to Order

D A 588
ATEX category 3

Auto switch model number Lead wire length


73 With indicator light Nil 0.5 m
80 Without indicator light L 3m
Z 5 m (Except A 80)
Electrical Entry
Nil Perpendicular
H In-line

81
ATEX Compliant
Reed Switch/Tie-rod Mounting
D-A54/D-A67-588
II 3G Ex nA II T5 X -10°C�≤�Ta�≤�+60°C Auto Switch Specifications
II 3D Ex tD A22 IP67 T93°C X
PLC: Programmable Logic Controller
D-A54 (With indicator light)
Auto switch model number D-A54
Grommet Applicable load Relay/PLC
Load voltage 24 VDC
Max. load current
5 to 50 mA
and range
Internal Circuit ∗ q
Contact protection circuit Built-in
Internal voltage drop 2.4 V or less (up to 20 mA) / 3.5 V or less (up to 50 mA)
Indicator light Red LED illuminates when turned ON
Standard CE marking
D-A67 (Without indicator light)
Auto switch model number D-A67
Applicable load PLC/IC circuit
Load voltage MAX. 24 VDC
Max. load current and range 30 mA
Internal Circuit ∗ r
Contact protection circuit None

Internal resistance 1 Ω or less (Including 3 m lead wire)

Standard CE marking

Oilproof Heavy-duty Lead Wire Specifications


Auto switch type D-A54/D-A67
Sheath Outside diameter [mm] ø4
Number of cores 2 cores (Brown, Blue)
Insulator
Outside diameter [mm] ø1.22
Cross section [mm2] 0.3
Conductor
Strand diameter [mm] ø0.08
Minimum bending radius of lead wire [mm] (Reference) 24
∗ For internal circuit, refer to the Internal Circuit No. on page 79.
This category 3 type auto switch can only be used in zones 2 and 22.

How to Order

D A 588
ATEX category 3

Auto switch model number Lead wire length


54 With indicator light Nil 0.5 m
67 Without indicator light L 3m
Z 5 m (Except D-A67)

82
ATEX Compliant
Reed Switch/Direct Mounting
D-A90(V)/D-A93(V)-588
II 3G Ex nA II T5 X -10°C�≤�Ta�≤�+60°C Auto Switch Specifications
II 3D Ex tD A22 IP67 T93°C X
PLC: Programmable Logic Controller
D-A90, D-A90V (Without indicator light)
Auto switch model number D-A90/D-A90V
Grommet Applicable load IC circuit/Relay/PLC
AC AC
Load voltage 24 V or less 48 V or less
DC DC

Max. load current 50 mA 40 mA


Internal Circuit ∗ r
Contact protection circuit None
Internal resistance 1 Ω or less (Including 3 m lead wire)
Standard CE marking
D-A93, D-A93V (With indicator light)
Auto switch model number D-A93/D-A93V
Applicable load Relay/PLC
Load voltage 24 VDC
Max. load current and
5 to 40 mA
load current range
Internal Circuit ∗ e
Contact protection circuit None
Internal voltage D-A 93 —— 2.4 V or less (up to 20 mA)/3 V or less (up to 40 mA)
drop D-A 93V —— 2.7 V or less
Indicator light Red LED illuminates when turned ON
Standard CE marking

Oilproof Heavy-duty Lead Wire Specifications


Auto switch type D-A90 (V)/D-A93 (V)
Sheath Outside diameter [mm] ø2.7
Number of cores 2 cores (Brown, Blue)
Insulator
Outside diameter [mm] ø0.96
Cross section [mm2] 0.18
Conductor
Strand diameter [mm] ø0.08
Minimum bending radius of lead wire [mm] (Reference) 17
∗ For internal circuit, refer to the Internal Circuit No. on page 79.
This category 3 type auto switch can only be used in zones 2 and 22.

How to Order

D A 588
ATEX category 3

Auto switch model number Lead wire length


93 With indicator light Nil 0.5 m
90 Without indicator light L 3m
Z 5 m (Except A90)
Electrical Entry
Nil In-line
V Perpendicular

83
ATEX Compliant
Reed Switch/Direct Mounting
D-90A/D-93A-588
II 3G Ex nA II T5 X -10°C ≤ Ta ≤ +60°C Auto Switch Specifications
II 3D Ex tD A22 IP67 T93°C X
PLC: Programmable Logic Controller
D-90A (Without indicator light)
Auto switch model number D-90A
Grommet Applicable load Relay/IC circuit/PLC
Lead wire: Heavy-duty cord AC
Load voltage 24 V
DC
Max. load current 50 mA
Internal Circuit ∗ r
Internal resistance 1 Ω or less (Including 3 m lead wire)
Standard CE marking
D-93A (With indicator light)
Auto switch model number D-93A
Applicable load Relay/PLC
Load voltage 24 VDC
Load current range 5 to 40 mA
Internal Circuit ∗ e
Internal voltage drop 2.4V or less
Indicator light Red LED illuminates when turned ON
Standard CE marking

Oilproof Heavy-duty Lead Wire Specifications


Auto switch type D-90A/D-93A
Sheath Outside diameter [mm] ø3.4
Number of cores 2 cores (Brown, Blue)
Insulator
Outside diameter [mm] ø1.1
Cross section [mm2] 0.2
Conductor
Strand diameter [mm] ø0.08
Minimum bending radius of lead wire [mm] (Reference) 21
∗ For internal circuit, refer to the Internal Circuit No. on page 79.
This category 3 type auto switch can only be used in zones 2 and 22.

How to Order

D A 588
ATEX category 3

Auto switch model number Lead wire length


93 With indicator light Nil 0.5 m
90 Without indicator light L 3m
Z 5m

84
ATEX Compliant
Reed Switch/Direct Mounting
D-Z73/D-Z80-588
II 3G Ex nA II T5 X -10°C�≤ Ta�≤ +60°C Auto Switch Specifications
II 3D Ex tD A22 IP67 T93°C X
PLC: Programmable Logic Controller
D-Z73 (With indicator light)
Auto switch model number D-Z73
Grommet Applicable load Relay/PLC
Load voltage 24 VDC
Max. load current and range 5 to 40 mA
Internal Circuit ∗ e
Contact protection circuit None
Internal voltage drop 2.4 V or less (up to 20 mA)/3 V or less (up to 40 mA)
Indicator light Red LED illuminates when turned ON
Standard CE marking
D-Z80 (Without indicator light)
Auto switch model number D-Z80
Applicable load Relay/PLC/IC circuit
AC AC
Load voltage 24 V DC or less 48 V DC

Max. load current 50 mA 40 mA


Internal Circuit ∗ r
Contact protection circuit None
Internal resistance 1 Ω or less (Including 3 m lead wire)
Standard CE marking

Oilproof Heavy-duty Lead Wire Specifications


Auto switch type D-Z73/D-Z80
Sheath Outside diameter [mm] ø2.7
Number of cores 2 cores (Brown, Blue)
Insulator
Outside diameter [mm] ø1.1
Cross section [mm2] 0.18
Conductor
Strand diameter [mm] ø0.08
Minimum bending radius of lead wire [mm] (Reference) 17
∗ For internal circuit, refer to the Internal Circuit No. on page 79.
This category 3 type auto switch can only be used in zones 2 and 22.

How to Order

D Z 588
ATEX category 3

Auto switch model number Lead wire length


73 With indicator light Nil 0.5 m
80 Without indicator light L 3m
Z 5 m (Except D-Z80)

85
ATEX Compliant
Reed Switch/Direct Mounting
D-E73A/D-E80A-588
II 3G Ex nA II T5 X -10°C�≤ Ta�≤ +60°C Auto Switch Specifications
II 3D Ex tD A22 IP67 T93°C X
PLC: Programmable Logic Controller
D-E73A (With indicator light)
Auto switch model number D-E73A
Grommet Applicable load Relay/PLC
Load voltage 24 VDC
Max. load current and range 5 to 40 mA
Internal Circuit ∗ e
Contact protection circuit None

Internal voltage drop 2.4 V or less

Indicator light Red LED illuminates when turned ON


Standard CE marking
D-E80A (Without indicator light)
Auto switch model number D-E80A
Applicable load Relay/PLC/IC circuit
AC AC
Load voltage 24 V DC or less 48 V DC

Max. load current 50 mA 40 mA


Internal Circuit ∗ r
Contact protection circuit None
Internal resistance 1 Ω or less (Including 3 m lead wire)
Standard CE marking

Oilproof Heavy-duty Lead Wire Specifications


Auto switch type D-E73A/D-E80A
Sheath Outside diameter [mm] ø3.4
Number of cores 2 cores (Brown, Blue)
Insulator
Outside diameter [mm] ø1.1
Cross section [mm2] 0.2
Conductor
Strand diameter [mm] ø0.08
Minimum bending radius of lead wire [mm] (Reference) 21
∗ For internal circuit, refer to the Internal Circuit No. on page 79.
This category 3 type auto switch can only be used in zones 2 and 22.

How to Order

D E A 588
ATEX category 3

Auto switch model number Lead wire length


73 With indicator light Nil 0.5 m
80 Without indicator light L 3m

86
ATEX Compliant
Reed Switch/Direct Mounting
D-R73/D-R80-588
II 3G Ex nA II T5 X -10°C�≤ Ta�≤ +60°C Auto Switch Specifications
II 3D Ex tD A22 IP67 T93°C X
PLC: Programmable Logic Controller
D-R73 (With indicator light)
Auto switch model number D-R731/D-R732
Grommet Applicable load Relay/PLC
Electrical entry: In-line Load voltage 24 VDC
Load current range 5 to 40 mA
Internal Circuit ∗ e
Internal voltage drop 2.4 V or less
Indicator light Red LED illuminates when turned ON
Standard CE marking
D-R80 (Without indicator light)
Auto switch model number D-R801/D-R802
Applicable load Relay/IC circuit/PLC
AC
Load voltage 24 V DC

Max. load current 50 mA


D-R2 D-R1 Internal Circuit ∗ r
Internal resistance 1 Ω or less (Including 3 m lead wire)
Standard CE marking

Oilproof Heavy-duty Lead Wire Specifications


Auto switch type D-R73/D-R80
Left hand mounting Right hand mounting
Sheath Outside diameter [mm] ø3.4
Number of cores 2 cores (Brown, Blue)
Insulator
Outside diameter [mm] ø1.1
Cross section [mm2] 0.2
Conductor
Strand diameter [mm] ø0.08
Minimum bending radius of lead wire [mm] (Reference) 21
∗ For internal circuit, refer to the Internal Circuit No. on page 79.
This category 3 type auto switch can only be used in zones 2 and 22.

How to Order

D R 588
ATEX category 3

Auto switch model number Lead wire length


73 With indicator light Nil 0.5 m
80 Without indicator light L 3m
Z 5m
Mounting
1 Right hand mounting
2 Left hand mounting

87
ATEX Compliant
Rotary Actuator: Vane Type

Series
Sizes:
55-CRB1
50, 63, 80, 100
90°C (T5) Ta 5°C to 40°C
II 2Gc 110°C (T4) Ta 40°C to 60°C

How to Order

Standard 55 CRB1 B W 80 90 S

ATEX category 2 Mounting Size Thread Port


B Basic 50 Nil Rc
L Foot 63 -XF G
80 -XN NPT
100
Shaft type
W Double shaft (long shaft with key and short shaft with four flats) Connecting port position
Nil Side ports
E Axial ports
Rotating angle Bolt
Classification Symbol Single vane Double vane
90 90° 90°
Standard

180 180° —
270 270° —
100 100° 100°
standard
Semi-

190 190° —
280 280° —
A port B port A port B port
Side ports Axial ports
Body end of the short-shaft side

Vane type
S Single vane
D Double vane

All other specifications are the same as the standard products Series CRB1.
For details, refer to the WEB catalog or Best Pneumatics No. 4.

88
ATEX Compliant
Rotary Actuator: Vane Type

Series
Sizes:
56-CRB1
50, 63, 80, 100
84°C (T6) Ta 5°C to 40°C
II 3G 104°C (T4) Ta 40°C to 60°C

How to Order

Without magnet 56 CRB1 B W 80 90 S

With magnet 56 CDRB1 B W 80 90 S


Thread Port
ATEX category 3 Size Nil Rc
50 -XF G
63 -XN NPT
80
With auto switch unit 100
Built-in magnet Connecting port position
Nil Side ports
E Axial ports
Mounting
B Basic Bolt
L Foot

Shaft type
W Double shaft (long shaft key & four chamfers)

A port B port A port B port


Rotating angle Side ports Axial ports
Classification Symbol Single vane Double vane Body end of the short-shaft side
90 90° 90°
Standard

180 180° —
270 270° —
Vane type
100 100° 100°
standard

S
Semi-

Single vane
190 190° —
D Double vane
280 280° —

All other specifications are the same as the standard products Series CRB1.
For details, refer to the WEB catalog or Best Pneumatics No. 4.

Refer to page 69 for applicable auto switches.

89
ATEX Compliant
Rotary Actuator: Vane Type

Series
Sizes:
55-CRB2
10, 15, 20, 30, 40
130°C (T4) Ta 5°C to 40°C
II 2Gc 150°C (T3) Ta 40°C to 60°C

How to Order

Standard 55 CRB2 B W 180 S E

ATEX category 2 Mounting Size Connecting port position


B Basic type 10 Nil Side ports
F Flange type 15 E Axial ports
∗ F: Except size 40 20
Side ports Axial ports
30
40
Shaft type
Double shaft with single flat (sizes 10 to 30)
W
Long shaft key, Short shaft with single flat (size 40)
∗ Fittings are sold separately.

Rotation Vane type


90 90° S Single vane
Single
180 180° D Double vane
vane
270 270°
Double 90 90°
vane 100 100°

All other specifications are the same as the standard products Series CRB2.
For details, refer to the WEB catalog or Best Pneumatics No. 4.

90
ATEX Compliant
Rotary Actuator: Vane Type

Series
Sizes:
56-CRB2
10, 15, 20, 30, 40
100°C (T5) Ta 5°C to 40°C
II 3G 120°C (T4) Ta 40°C to 60°C

How to Order

Without
magnet
56 CRB2 B W 180 S E
Connecting port position

56 CDRB2 B W 180 S Nil Side ports


With magnet E Axial ports

Side ports Axial ports

ATEX category 3 Size


10
15
20
With auto switch unit ∗ Fittings are sold separately.
30
Built-in magnet
40

Mounting Vane type


B Basic S Single vane
F Flange D Double vane
∗ F: Except size 40

Shaft type Rotation


90 90°
Double shaft with single flat (sizes 10 to 30) Single
W 180 180°
Long shaft with key, short shaft with single flat (size 40) vane
270 270°
Double 90 90°
vane 100 100°

All other specifications are the same as the standard products Series CRB2.
For details, refer to the WEB catalog or Best Pneumatics No. 4.

Refer to page 69 for applicable auto switches.

91
ATEX Compliant
Rotary Actuator: Free Mount Type

Series
Sizes:
55-CRBU2
10, 15, 20, 30, 40
130°C (T4) Ta 5°C to 40°C
II 2Gc 150°C (T3) Ta 40°C to 60°C

How to Order

Standard 55 CRBU2 W 10 180 S E

ATEX category 2 Size Connecting port position


10 Nil Side ports
15 E Axial ports
20
Free mount type Axial ports Side ports
30
40

Shaft type
Double shaft with single flat (sizes 10 to 30)
W
Long shaft with key, short shaft with single flat (size 40) ∗ Fittings are sold separately.

Vane type
S Single vane
D Double vane

Rotation
90 90°
Single
180 180°
vane
270 270°
Double 90 90°
vane 100 100°

All other specifications are the same as the standard products Series CRBU2.
For details, refer to the WEB catalog or Best Pneumatics No. 4.

92
ATEX Compliant
Rotary Actuator: Free Mount Type

Series
Sizes:
56-CRBU2
10, 15, 20, 30, 40
100°C (T5) Ta 5°C to 40°C
II 3G 120°C (T4) Ta 40°C to 60°C

How to Order

Without 56 CRBU2 W 10 180 S E


magnet
Connecting port position
With magnet 56 CDRBU2 W 20 180 S Nil
E
Side ports
Axial ports

Axial ports Side ports

ATEX category 3 Size


10
15
20
With auto switch unit ∗ Fittings are sold separately.
Built-in magnet 30
40

Free mount type Vane type


S Single vane
D Double vane
Shaft type
Double shaft with single flat (sizes 10 to 30)
W
Long shaft with key, short shaft with single flat (size 40)
Rotation
90 90°
Single
180 180°
vane
270 270°
Double 90 90°
vane 100 100°

All other specifications are the same as the standard products Series CRBU2.
For details, refer to the WEB catalog or Best Pneumatics No. 4.

Refer to page 69 for applicable auto switches.

93
ATEX Compliant
Compact Rotary Actuator
Rack & Pinion Type

Series
II 2Gc
55-CRQ2
70°C (T6) Ta 0°C to 40°C
90°C (T5) Ta 40°C to 60°C

How to Order

Without
magnet 55 CRQ2B S 20 90

With magnet 55 CDRQ2B S 20 90

ATEX category 2 Shaft type Cushion


S Single shaft Size
Symbol Cushion
W Double shaft 10 15 20 30 40
Without cushion — —   
Built-in magnet for auto switch Nil
Rubber cushion   — — —
Size C Air cushion — —   

10
15
20 Rotation
30 90 80° to 100°
40 180 170° to 190°

Port thread
Size Port thread
10, 15 Nil M5
Nil Rc 1/8
TF G 1/8
20, 30, 40
TN NPT 1/8
TT NPTF 1/8

All other specifications are the same as the standard products Series CRQ2.
For details, refer to the WEB catalog or Best Pneumatics No. 4.

Refer to page 69 for applicable auto switches.

94
ATEX Compliant
Compact Rotary Actuator
Rack & Pinion Type

Series
II 3G
56-CRQ2
60°C (T6) Ta 0°C to 40°C
80°C (T6) Ta 40°C to 60°C

How to Order

Without
magnet 56 CRQ2B S 20 90

With magnet 56 CDRQ2B S 20 90

ATEX category 3 Shaft type Cushion


S Single shaft Size
Symbol Cushion
W Double shaft 10 15 20 30 40
Built-in magnet for auto switch Without cushion — —   
Nil
Rubber cushion   — — —
Size C Air cushion — —   

10
15
20 Rotation
30 90 80° to 100°
40 180 170° to 190°

Port thread
Size Port thread
10, 15 Nil M5
Nil Rc 1/8
TF G 1/8
20, 30, 40
TN NPT 1/8
TT NPTF 1/8

All other specifications are the same as the standard products Series CRQ2.
For details, refer to the WEB catalog or Best Pneumatics No. 4.

Refer to page 69 for applicable auto switches.

95
ATEX Compliant
Booster Regulator

Series
10A to 43A
56-VBA RoHS
II 3 GD c T6 Ta 2°C to 50°C

How to Order

56-VBA 40A 04
ATEX category 3 Semi-standard
Symbol Specifications
Body size Nil Standard product
10A 1/4, Handle-operated type Pressure increase ratio: Twice Pressure unit on the product name label
11A 1/4, Handle-operated type Pressure increase ratio: 2 to 4 times Z Note) and pressure gauge: psi
20A 3/8, Handle-operated type
Note) Thread type: NPT, NPTF
40A 1/2, Handle-operated type Under the new measurement law, the
22A 3/8, Air-operated type Pressure increase ratio: Twice pressure unit of “psi” on the pressure
42A 1/2, Air-operated type gauges cannot be used in Japan.
43A 1/2, Max. operating pressure 1.6 Mpa
Options
Thread type Note) Symbol Options
Symbol Thread type Nil None
Nil Rc G Pressure gauge
F G N Silencer
N NPT S High-noise reduction silencer Note)
T NPTF GN Pressure gauge, Silencer
Note) Thread types apply to the IN, GS Pressure gauge, High-noise reduction silencer Note)
OUT, and EXH ports of the LN Elbow silencer Note)
VBA1A and to the IN, OUT, LS Elbow high-noise reduction silencer Note)
EXH, and gauge ports of the GLN Pressure gauge, Elbow silencer Note)
VBA2A and VBA4A.
GLS Pressure gauge, Elbow high-noise reduction silencer Note)
The gauge ports of the
VBA1A are Rc thread type Note) Refer to “Combination of Thread Type and Options.”
regardless of the thread type
indication. Port size
Symbol Port size Applicable series
02 1/4" VBA1A
03 3/8" VBA2A
04 1/2" VBA4A

Combination of Thread Type and Options


Thread Options Semi-standard
Body size
type Nil G N S GN GS LN LS GLN GLS Nil -Z
Nil            —
10A F            —
11A N    —  —  —  —  
T    —  —  —  —  
Nil        —
20A F        —
22A N        
T        
Nil        —
40A
F        —
42A
N        
43A
T        

All other specifications are the same as the standard products Series VBA.
For details, refer to the WEB catalog or Best Pneumatics No. 5.

96
ATEX Compliant
Digital Pressure Switch for Air

Series 56-ISE70
II 3G Ex nA II T5 X 0°C ≤ Ta ≤ 50°C
II 3D tD A22 IP67 T53°C X

How to Order

1MPa 56 ISE70 02 43 M
ATEX category 3 Piping specifications Option 2
02 Rc1/4 Nil None
N02 NPT1/4 With bracket
F02 G1/4 (ISO1179)

Output specifications
2 settings
27 A
NPN open collector 2 outputs (Pin no.: 2, 4)
Fixed setting: (The pressure set point for
switching the output signal is common to
43 NPN and PNP.)
NPN open collector 1 output (Pin no.: 4) + Note) Mounting screws
PNP open collector 1 output (Pin no.: 2) are not included.

Fixed setting
65
PNP open collector 1 output (Pin no.: 4)
Option 1
2 settings
67 Nil None
PNP open collector 2 outputs (Pin no.: 2, 4)
Lead wire with M12 connector (5 m),
S
straight
Unit specifications
Lead wire with M12 connector (5 m),
Nil With display unit switching function Note 1) L
right-angled
M Fixed SI unit Note 2)
Pressure unit: psi (Initial value)
P
With display unit switching function Note 1)
Note 1) Under the New Measurement Law, sales of
switches with the unit switching function are not
allowed for use in Japan. (Initial value: MPa)
Note 2) Fixed unit: Mpa

Specifications

Model 56-ISE70
Rated pressure range 0 to 1 MPa
Pressure display range/Set pressure range −0.1 to 1 MPa
Withstand pressure 1.5 MPa
Pressure display resolution/Minimum unit setting 0.01 MPa
Applicable fluid Air, Non-corrosive gas, Non-flammable gas
Power supply voltage 12 to 24 VDC±10%, Ripple (p-p) 10% or less (with power supply polarity protection)
Current consumption 55 mA or less (at no load)
Follow the instructions given below when handling the pressure switch.
• Operating temperature range is 0 to 50°C
• Do not expose the pressure switch to heat radiation from a heat source located nearby. It can cause malfunction.
• Do not expose the pressure switch/connector/cable to vibration and impact. Otherwise it can cause damage or malfunction.
• Protect the product from direct sunlight or UV light using a suitable protective cover.
• Do not disconnect the M12 connector while energized.
• Use only an ATEX approved M12 connector.
• For cleaning this product, use a clean and damp cloth, to prevent the buildup of an electrostatic charge.
• Ground properly to prevent the buildup of an electrostatic charge.

All other specifications are the same as the standard products Series ISE70.
For details, refer to the WEB catalog or Best Pneumatics No. 6.

97
ATEX Compliant
Digital Pressure Switch for General Fluids

Series 56-ISE75/75H
II 3G Ex nA II T4 X -5°C ≤ Ta ≤ 50°C
II 3D tD A22 IP67 T54°C X

How to Order

10MPa 56 ISE75 02 43 M
15MPa 56 ISE75H 02 43 M
ATEX category 3 Piping specifications Option 2
02 Rc1/4 Nil None
N02 NPT1/4 With bracket
F02 G1/4 (ISO1179)

Output specifications
2 settings
27
NPN open collector 2 outputs (Pin no.: 2, 4)
A
Fixed setting: (The pressure set point for
switching the output signal is common to
43 NPN and PNP.)
NPN open collector 1 output (Pin no.: 4) +
PNP open collector 1 output (Pin no.: 2) Note) Mounting screws
are not included.
Fixed setting
65
PNP open collector 1 output (Pin no.: 4)
Option 1
2 settings
67 Nil None
PNP open collector 2 outputs (Pin no.: 2, 4)
Lead wire with M12 connector (5 m),
S
Unit specifications straight
Nil With display unit switching function Note 1) Lead wire with M12 connector (5 m),
L
M Fixed SI unit Note 2) right-angled
Pressure unit: psi (Initial value)
P
With display unit switching function Note 1)
Note 1) Under the New Measurement Law, sales of
switches with the unit switching function are not
allowed for use in Japan. (Initial value: MPa)
Note 2) Fixed unit: Mpa

Specifications

Model 56-ISE75 56-ISE75H


Rated pressure range 0 to 10 MPa 0 to 15 MPa
Pressure display range/Set pressure range 0.4 to 10 MPa 0.5 to 15 MPa
Withstand pressure 30 MPa 45 MPa
Pressure display resolution/Minimum unit setting 0.1 MPa
Applicable fluid Fluid or gas that will not corrode SUS304, SUS430 and SUS630
Power supply voltage 12 to 24 VDC±10%, Ripple (p-p) 10% or less (with power supply polarity protection)
Current consumption 55 mA or less (at no load)
Follow the instructions given below when handling the pressure switch.
• Operating temperature range is − 5 to 50°C
• Do not expose the pressure switch to heat radiation from a heat source located nearby. It can cause malfunction.
• Do not expose the pressure switch/connector/cable to vibration and impact. Otherwise it can cause damage or malfunction.
• Protect the product from direct sunlight or UV light using a suitable protective cover.
• Do not disconnect the M12 connector while energized.
• Use only an ATEX approved M12 connector.
• For cleaning this product, use a clean and damp cloth, to prevent the buildup of an electrostatic charge.
• Ground properly to prevent the buildup of an electrostatic charge.

All other specifications are the same as the standard products Series ISE75/ISE75H.
For details, refer to the WEB catalog or Best Pneumatics No. 6.

98
ATEX Compliant 2 Port Steam Valve
Steam Valve

Series II 3G TX
56-VND
-5°C ≤ Ta ≤ 60°C

How to Order
Body option
Thread type
Nil Standard (Copper alloy) Nil Rc
Note) S Stainless steel body F G
Note) Threaded type only N NPT
T NPTF

Air operated 56 VND 2 0 D S 15A

ATEX category 3 Options


Nil None
Note)B With bracket
L With indicator light(visual verification of operation)
Note) BL With bracket and indicator light(visual verification of operation)

Note) Brackets (for valve size 1/2/3/4 only) will be


assembled at the time of shipment.
Bracket part no.
Valve size 1: VN1-A16 (with thread)
Valve size 2 to 4: VN-16
2 to 4
Valve size Valve type Port size
Symbol
Orifice dia. Port size
Symbol 0 2 4 Symbol
(mm) Rc
N.C. N.O. N.C.
—   6A 18
1 ø7 —   8A 14
—   10A 38
  — 10A 38
2 ø15
  — 15A 12
3 ø20   — 20A 34
4 ø25   — 25A 1
  — 32A 11 4
5 ø32
  — 32F 11 4 B Flange
  — 40A 11 2
6 ø40
  — 40F 11 2 B Flange
  — 50A 2
7 ø50   — 50F 2 B Flange

All other specifications are the same as the standard products Series VND.
For details, refer to the WEB catalog or Best Pneumatics No. 7.

99
Valve for Water and Chemical Base Fluids
ATEX Compliant
(2/3 Port Air Operated Valve)

Series
II 2GD c 75°C T6 X
VCC
+5°C ≤ Ta ≤ +50°C

How to Order

Valve
VCC1 2 00
Passage number Port size
VCC12(D)-00 VCC13-00
2 2 port valve 00 For manifold mounting
3 3 port valve Note) 02 Rc1/4 (for single unit) Note)
2D 2 port/Diaphragm type (Applicable for 2 liquid paint) 02F G1/4 (for single unit) Note)
Note) Pressure cannot be applied from a 3 port valve Note) Part number for sub-base
RETURN port. For 2 port: VCC12-S- 02 [Rc1/4]
02F [G1/4]
For 3 port: VCC13-S- 02 [Rc1/4]
02F [G1/4]

VCC12(D)-02(F) VCC13-02(F)

Manifold
Standard VV M CC1 06 06 C4
Type (Passage number) Pilot port fitting size
2 2 port valve, Cleaning valve C4 ø4 One-touch fitting (Antistatic)
3 3 port valve C6 ø6 One-touch fitting (Antistatic)
M 2/3 port valves mixed mounting

2 port valve mountable number 3 port valve mountable number


00 No 2 port valves used 00 No 3 port valves used
02 2 pcs. (colours) 02 2 pcs. (colours)
04 4 pcs. (colours) 04 4 pcs. (colours)

Note) Maximum mountable valve number: 40 pcs. (total of 2 port and 3 port valves)

Circuit example
2 port valve 3 port valve 2 port valve
1 pc.
3 pcs.
RETURN RETURN RETURN 5 pcs. 3 port valve
IN PA IN PA IN PA IN PA IN PA IN PA 1 pc.
3 pcs.
5 pcs.

OUT
2 pcs.
4 pcs.
6 pcs.
2 pcs.
IN PA IN PA IN PA 4 pcs.
IN PA IN PA IN PA
RETURN RETURN RETURN 6 pcs.

All other specifications are the same as the standard products Series VCC.
For details, refer to the WEB catalog or Best Pneumatics No. 7.

100
Series VCC
ATEX Compliant
Valve for Water and Chemical Base Fluids

How to Order

Manifold
With gate valve VV M CC1 02 06 C4 G 04
Passage number Gate valve and cleaning valve mountable number
2 2 port valve, Cleaning valve
02 Cleaning valve (2 port valve): 1 pc. + Gate valve: 1 pc.
M 2/3 port valves mixed mounting
04 Cleaning valve (2 port valve): 3 pcs. + Gate valve: 1 pc.
06 Cleaning valve (2 port valve): 5 pcs. + Gate valve: 1 pc.
2 port valve mountable number
00 No 2 port valves used Pilot port fitting size
02 2 pcs. (colours) C4 ø4 One-touch fitting (Antistatic)
04 4 pcs. (colours) C6 ø6 One-touch fitting (Antistatic)

3 port valve mountable number


00 No 3 port valves used
02 2 pcs. (colours)
04 4 pcs. (colours)

Note) Maximum mountable valve


number: 40 pcs. ∗ The gate valve and cleaning valve (2 port valve) are not included.
(total of 2 port, 3 port and They are ordered separately.
gate valves) (Gate valve is equivalent to 2 port valve.)
∗ When cleaning valve number is an even number, use the blanking
Circuit example plug for 2 port valve.

Gate/Cleaning valve 2/3 port valve


Cleaning valve
RETURN RETURN RETURN
Cleaning valve
IN PA IN PA IN PA IN PA IN PA IN PA

OUT

Cleaning valve

Gate valve OUT


IN PA PA IN PA IN PA IN PA IN PA
RETURN RETURN RETURN
Gate valve

All other specifications are the same as the standard products Series VCC.
For details, refer to the WEB catalog or Best Pneumatics No. 7.

101
ATEX Compliant Air operated type
Threaded Type

55-LVA
55-LVA10 and 55-LVA12
II 2G c IIB T6 X Ta 0°C to +50°C

Series
II 2G c IIB TXX Ta 0°C to +60°C
Special condition X "Protect from impact"
55-LVA2, 55-LVA3, 55-LVA4, 55-LVA5,
55-LVA6 and 55-LVA200
II 2GD c IIB 80°C T6 X Ta 0°C to +50°C
II 2GD c IIB TXX Ta 0°C to +60°C
Special condition X "Protect from impact"
Note) The manifold type is not available with
How to Order Valves (Single Type) ATEX certification

55 LVA 2 0 02 A
ATEX category 2 Options
Body class Nil None
Symbol Body class Orifice dia. 1 With flow rate adjustment
1 1 ø2 2 With bypass (PFA body only)
2 2 ø4 3 With flow rate adjustment & bypass (PFA body only)
3 3 ø8 4 With indicator
4 4 ø12 Note) Refer to “Variations” in the table below for option
5 5 ø20 combinations. Options can not be combined each other.
6 6 ø22

Valve type Material


Actuator section Applicable option
0 N.C. Port size Symbol Body Diaphragm Note
1 End plate 1 2 3 4
N.O. Symbol Port size Body class
2 PPS
Double acting 01 1/8 A SUS PTFE   —
1 —
Note) Refer to “Series 02 1/4
Variations” in 01 1/8 PPS PTFE 55-LVA10 to 40
B PPS  
the table below 2
for valve type 02 1/4
combinations. 02 1/4 C PFA PPS PTFE     55-LVA20 to 40
3
03 3/8
PPS
03 3/8 D SUS NBR   55-LVA10 to 50
4 —
04 1/2
PPS
04 1/2 E SUS EPR   55-LVA10 to 50
5 —
06 3/4
Hydrofluoric acid compatible
10 1 6 F PFA PVDF PTFE
Specifications Only 55-LVA40
55-LVA10 55-LVA20 55-LVA30 Thread type G PPS PPS NBR   55-LVA10 to 40
Model
55-LVA40 55-LVA50 55-LVA60 Symbol Thread type
Fluid temperature Temperature class T6 0 to 50 Nil Rc EPR 55-LVA10 to 40
H PPS PPS  
(°C) Temperature class TX 0 to 100 N NPT
Ambient temperature Temperature class T6 0 to 50 F G PTFE
Ammonium hydroxide compatible
N PFA PPS    
(°C) Temperature class TX 0 to 60 55-LVA20 to 40

Series Variations
Model 55-LVA10 55-LVA20 55-LVA30 55-LVA40 55-LVA50 55-LVA60 Note) Refer to the “Material” table for the
Orifice dia.
ø2 ø4 ø8 ø12 ø20 ø22 applicable optional body materials.
Port size
Body 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 1/2 3/4 1
SUS31
material Note) 6           
PPS
Valv PFA
  —  —  —  — — —
e typ
Type Symbol e — — —  —  —  — — —
Basic
N.C.           
PA PB PA

B A B AB A
N.O. — —         
PB
N.C. N.O. Double
acting Double acting           

With flow rate PA PA


adjustment N.C. — —         
B A B A
PB Double acting — —         
N.C. Double acting

With by-pass PA PA N.C. — — — — —  —  —  —


B A B A
Body material PB Double acting — — — — —  —  —  —
Only PFA N.C. Double acting

With flow rate PA PA


adjustment N.C. — — — — —  —  —  —
& by-pass B A B A All other specifications are
Body material PB
Double acting
Only PFA N.C. Double acting
— — — — —  —  —  — the same as the standard
With indicator PA
products Series LVA.
For details, refer to the WEB
B A N.C. — —          catalog or Best Pneumatics
N.C. No. 7.

102
ATEX Compliant Air operated type
Threaded Type

55-LVA
55-LVA10 and 55-LVA12
II 2G c IIB T6 X Ta 0°C to +50°C

Series
II 2G c IIB TXX Ta 0°C to +60°C
Special condition X "Protect from impact"
55-LVA2, 55-LVA3, 55-LVA4, 55-LVA5,
55-LVA6 and 55-LVA200
II 2GD c IIB 80°C T6 X Ta 0°C to +50°C
II 2GD c IIB TXX Ta 0°C to +60°C
Special condition X "Protect from impact"
Note) The manifold type is not available with
How to Order Valves ATEX certification

55 LVA 2 0 0 02 C
ATEX category 2 Material
Symbol Body Actuator section Diaphragm
Body class C PFA PPS PTFE
Symbol Body class Orifice dia.
2 2 ø4 Thread type
Symbol Thread type
Valve type Nil Rc
0 N.C. N NPT

Port size
Symbol Port size
02 1/4

All other specifications are the same as the standard products Series LVA.
For details, refer to the WEB catalog or Best Pneumatics No. 7.

103
ATEX Compliant Process Pump
Automatically operated type (Internal switching type)/
Air operated type (External switching type)

Series 55-PA3000/5000
For 55-PA30: II 2 GD c T6 Ta 0°C to +60°C
For 55-PA33: II 2 GD c T5 Ta 0°C to +60°C
For 55-PA5: II 2 GD c T6 Ta 0°C to +60°C
For 55-PA53: II 2 GD c T6 Ta 0°C to +60°C

How to Order

55 PA 3 1 1 0 03
ATEX category 2
Body size Options
Symbol Body size Applicable actuation
3 3/8 standard Symbol Options Automatically
Air operated type
5 1/2 standard operated type
Nil None  
N With silencer  —
Liquid contact body material ∗ A silencer of 2504-002 (NPT: 2504-N002) is provided.
Symbol Body material
1 ADC12 (Aluminum)
2 SCS14 (Stainless steel)
Port size
Applicable model
Symbol Port size
Diaphragm material PA3000 PA5000
Applicable actuation 03 3/8"  —
Symbol Diaphragm material Automatically 04 1/2" — 
Air operated type 06 3/4" — 
operated type
1 PTFE  
2 NBR  —
Thread type
∗ Dimensions are the same as the standard products.
Symbol Type
Actuation Nil Rc
Symbol Actuation
N NPT
0 Automatically operated type
F G
3 Air operated type
T NPTF

All other specifications are the same as the standard products Series PA3000/5000.
For details, refer to the WEB catalog or Best Pneumatics No. 7.

104
ATEX Compliant Process Pump
Automatically operated type (Internal switching type)/
Air operated type (External switching type)

Series 56-PA3000/5000
II 3 GD c T6 Ta 0°C to +60°C

How to Order

56 PA 3 1 1 0 03
ATEX category 3
Body size Options
Symbol Body size Applicable model
3 3/8 standard Symbol Options Automatically
Air operated type
5 1/2 standard operated type
Nil None  
N With silencer  —
Liquid contact body material
Symbol Body material
1 ADC12 (Aluminum) Port size
2 SCS14 (Stainless steel) Applicable model
Symbol Port size
PA3000 PA5000
03 3/8"  —
Diaphragm material 04 1/2" — 
Applicable model 06 3/4" — 
Symbol Diaphragm material Automatically
Air operated type
operated type
1 PTFE   Thread type
2 NBR  — Symbol Type
∗ Dimensions are the same as the standard products. Nil Rc
N NPT
Actuation F G
Symbol Actuation T NPTF
0 Automatically operated type
3 Air operated type

All other specifications are the same as the standard products Series PA3000/5000.
For details, refer to the WEB catalog or Best Pneumatics No. 7.

105
ATEX Compliant
Pneumatic-Pneumatic Positioner

Series 55-IP5000/5100
II 2GDc T4-T6

How to Order

55 IP5 000 0 1 0
Accessories Note 1)
ATEX
Without accessory With standard lever (10 to
category 2 Nil
(standard) 85 mm stroke) for IP5000
Positioner type With ø0.7 output restrictor
A Common to IP5000 and
000 Lever type integrated pilot valve
100 Rotary type IP5100 small capacity
With ø1.0 output restrictor actuators
B
integrated pilot valve
C With fork lever type fitting M
Input pressure Only for IP5100
D With fork lever type fitting S
0 0.2 to 1.0 MPa (Standard)
1/2 split With lever unit for a 35 to
1 E
0.02 to 0.06, 0.06 to 0.1 MPa 100 mm stroke
Only for IP5100 Note 2)
With lever unit for a 50 to
F
140 mm stroke
Pressure gauge (SUP, OUT1) Note 1) If multiple accessories are required, they should be indicated
0 Not provided in alphabetical order.
1 0.2 MPa ex. 55-IP5000-010-AD
Note 2) For ''E'' and ''F'', standard lever is not provided.
2 0.3 MPa
3 1.0 MPa

Pressure gauge/Air port


Indication of opening Note) Nil Rc (Standard)
N NPT
0 Not provided
F G
1 Indicated
Note) 55-IP5000 is available only
with option ''0'' (no indication).

Ambient temperature
Nil −20 to 80°C (Standard)
T −5 to 100°C (High temperature)
L −30 to 60°C (Low temperature)
Note) Please refer to table below

Specifications

Ambient temperature range


Classification Low temperature Standard High temperature
55-IP500-L- 55-IP500-- 55-IP500-T-
II 2GD c T4 – – -5°C ≤ Ta ≤ 100°C
II 2GD c T5 – -20°C ≤ Ta ≤ 80°C -5°C ≤ Ta ≤ 80°C
II 2GD c T6 -30°C ≤ Ta ≤ 60°C -20°C ≤ Ta ≤ 60°C -5°C ≤ Ta ≤ 60°C

All other specifications are the same as the standard products


Series IP5000/5100.
For details, refer to the WEB catalog or Series IP5000/5100
(CAT.ES60-13).

106
ATEX Compliant
Pneumatic-Pneumatic Positioner

Series 56-IP5000/5100
II 3GDc T4-T6

How to Order

56 IP5 000 0 1 0
Accessories Note 1)
ATEX category 3
Without accessory With standard lever (10 to
Nil
(standard) 85 mm stroke) for IP5000
Positioner type With ø0.7 output restrictor
A Common to IP5000 and
000 Lever type integrated pilot valve
100 Rotary type IP5100 small capacity
With ø1.0 output restrictor actuators
B
integrated pilot valve
C With fork lever type fitting M
Input pressure Only for IP5100
D With fork lever type fitting S
0 0.2 to 1.0 MPa (Standard)
1/2 split With lever unit for a 35 to
1 E
0.02 to 0.06, 0.06 to 0.1 MPa 100 mm stroke
Only for IP5100 Note 2)
With lever unit for a 50 to
F
140 mm stroke
Pressure gauge (SUP, OUT1) Note 1) If multiple accessories are required, they should be indicated
0 Not provided in alphabetical order.
1 0.2 MPa ex. 56-IP5000-010-AD
Note 2) For ''E'' and ''F'', standard lever is not provided.
2 0.3 MPa
3 1.0 MPa
Pressure gauge / Air port
Nil Rc (Standard)
Indication of opening Note) N NPT
0 Not provided F G
1 Indicated
Note) 55-IP5000 is available only
with option ''0'' (no indication).

Ambient temperature
Nil −20 to 80°C (Standard)
T −5 to 100°C (High temperature)
L −30 to 60°C (Low temperature)
Note) Please refer to table below

Specifications

Ambient temperature range


Low temperature Standard High temperature
Classification 56-IP500-L- 56-IP500-- 56-IP500-T-
II 3GD c T4 – – -5°C ≤ Ta ≤ 100°C
II 3GD c T5 – -20°C ≤ Ta ≤ 80°C -5°C ≤ Ta ≤ 80°C
II 3GD c T6 -30°C ≤ Ta ≤ 60°C -20°C ≤ Ta ≤ 60°C -5°C ≤ Ta ≤ 60°C

All other specifications are the same as the standard products


Series IP5000/5100.
For details, refer to the WEB catalog or Series IP5000/5100
(CAT.ES60-13).

107
ATEX CompliantElectro-Pneumatic Positioner
(Lever type/Rotary type)

Series IP6000-X14/6100-X14
II 2G Ex ib IIC T5/T6

How to Order

IP6 000 0 1 0 X14


ATEX category 2

Positioner type
Accessories Note)
000 Lever type
100 Rotary type Without accessory With standard lever (10 to 85 mm
Nil
(standard) stroke) for IP6000
With ø0.7 output restrictor
A Common to IP6000 and
integrated pilot valve
Pressure gauge (SUP, OUT1) 6100 small capacity
With ø1.0 output restrictor actuators
1 0.2 MPa B
integrated pilot valve
2 0.3 MPa
C With fork lever type fitting MX
3 1.0 MPa Only for IP6100
D With fork lever type fitting SX
With lever unit for a 35 to
E
100 mm stroke
Only for IP6000
With lever unit for a 50 to
F
140 mm stroke
G With compensation spring (A) Common to IP6000 and 6100
Note) If multiple accessories are required, they should be indicated in alphabetical
order.
ex. IP6000-011-AG-X14

Specifications

IP6000 IP6100
Type
Lever type lever Rotary type cam
Item
Single acting Double acting Single acting Double acting
Input current 4 to 20 mADC (Standard) Note1)
Input resistance 235 ± 15Ω (4 to 20 mADC)
Supply air pressure 0.14 to 0.7 MPa
10 to 85 mm
Standard stroke 60° to 100° Note 2)
(External lever allowable runout angle 10° to 30°)
Sensitivity Within 0.1% F.S. Within 0.5% F.S.
Linearity Within ± 1% F.S. Within ± 2% F.S.
Hysteresis Within 0.75% F.S. Within 1% F.S.
Repeatability Within ± 0.5% F.S.
Thermal coefficient Within 0.1% F.S./°C
Output flow rate Note 3) 80 L/min (ANR) or more (SUP = 0.14 MPa)

Air consumption Note 3) Within 5 L/min (ANR) (SUP = 0.14 MPa)

Ambient and using −20°C to 80°C (T5)


fluid Temperature −20°C to 60°C (T6)
ATEX intrinsically safe explosion proof structure
Explosion protected
( 0344 II 2G Ex ib II C T5/T6)
Construction
Approval No. KEMA 03 ATEX1119
Air connection port 1/4 NPT female screw
Electric wiring connection port M20 x 1.5
Material Aluminium diecast for the body
Weight Approx. 2.4 kg
Classification of degree
JIS F8007 IP55 (Conform to IEC 60529)
of protection
Parameters All other specifications are the same as the standard
Ui ≤ 28V, Ii ≤ 125mA, Pi ≤ 1.2W, Ci ≤ OnF, Li ≤ OmH
(Current circuit) products Series IP6000/6100.
Note 1) 1/2 split range is possible with the standard type (by adjusting the span). For details, refer to the WEB catalog or Series
Note 2) The stroke is adjustable in 0° to 60° and 0° to 100°. IP6000/6100 (CAT.ES60-11).
Note 3) Standard air (JIS B0120): temp. 20°C, absolute press. 760 mmHg, ratio humidity 65%.

108
ATEX Compliant
Electro-Pneumatic Positioner/Lever type Series IP6000-X14

Dimensions/IP6000
IP6000-00--X14 (Lever type)

(OUT2.1/4NPT) 40 110
35
Plugged
OUT2

SMC M
MPa A
{bar}

65
SPAN
SMC
MPa
{bar}

22.5
E

Zero adjusting knob


4 x M8 x 1.25 depth 12 A
Span adjusting knob
(Female thread for mounting,
backside)
Pressure gauge port 2 x Rc1/8
2 x M8 x 1.25 depth 12
OUT1.1/4NPT 168 SMC ELECTRO-PNEUMATIC POSITIONER
MODEL NO. IP6*00-0*0-*-X14-* Serial No.***** (Female thread for mounting,
38 15 B
SUPPLY 0.14 to 0.7MPa(1.4 to 7bar )

side position)
SUP.1/4NPT
INPUT 0/4 to 20mADC 20** MADE IN JAPAN
UI� 28V II� 125mA P� 1.2V CI� 0nf LI� 0nH
EExIb CT6 Ta � 60C
EExIb CT5 Ta � 80C
SMC Corporation KEMA No.03ATEX1119
11

1-16-4 Shinbashi Minatoku Tokyo 105-8659 Japan


15

OUT2

SMC
MPa
B
35

42
{bar}
35

122
100

6.1
16
SMC
130

20
MPa
{bar}

A
E
P

50
MODEL IP6000

At accessory “E”: 110


M

125 5
At accessory “F”: 110
At accessory "E": 195
E

150 At accessory "F": 275

53 M20 x 1.5 125 46


Porting for electrical =180
connection

Mark ''M'' means that


this port is ''M'' thread
110

NP
30
2
14

109
ATEX Compliant
Electro-Pneumatic Positioner/Rotary type Series IP6100-X14

Dimensions/IP6100
IP6100-00--X14 (Rotary type)

Positioner body
(OUT2.1/4NPT) 40 110
35
Hold spring Plugged
OUT2

C C

{bar}
MPa
SMC
7

M
A

24 C-C
70(46)
63(39)

65
{bar}
MPa
SMC
Fork pin unit
Fork lever type fitting

22.5
0
21

DA
M6 x 1 E

Main shaft of actuator SPAN

Dimension of optional fork lever


assembly type “MX” Zero adjusting knob A
( ) Shows dimension of fork lever assembly type ''SX'' 4 x M8 x 1.25 depth 12
(Female thread for mounting, backside)
Pressure gauge port 2 x Rc1/8
OUT1.1/4NPT 168
38 SUP.1/4NPT
SMC ELECTRO-PNEUMATIC POSITIONER
15
B
MODEL NO. IP6*00-0*0-*-X14-* Serial No.*****
SUPPLY 0.14 to 0.7MPa(1.4 to 7bar )
INPUT 0/4 to 20mADC 20** MADE IN JAPAN
UI� 28V II� 125mA P� 1.2V CI� 0nf LI� 0nH
EExIb CT6 Ta � 60C
11

EExIb CT5 Ta � 80C OUT2


15

SMC Corporation KEMA No.03ATEX1119


1-16-4 Shinbashi Minatoku Tokyo 105-8659 Japan
{bar}
MPa
SMC

B
35

42
35
100

90o
E P
{bar}

60o
MPa
SMC

20
130

30o

122
A
MODEL IP6100

50
Oo
30o
M

60o

90o
E

46
53 M20 x 1.5 125
=180 2 x M8 x 1.25 depth 12
Porting for electrical connection
(Female thread for mounting,
side position)
Mark ''M'' means that
this port is ''M'' thread
116

NP
44

110
ATEX CompliantElectro-Pneumatic Positioner
(Lever type/Rotary type)

Series IP8000-X14/8100-X14
II 2G Ex ib IIC T5/T6

How to Order

ATEX Directive Intrinsically


Safe Explosion Proof IP8 000 0 1 0 X14
Positioner type Option Note 7)
000 Electro-pneumatic lever type Applicable model
Symbol Option
100 Electro-pneumatic rotary type IP8000-X14 IP8100-X14
Nil —  
Pressure gauge L Low temperature (−40 to 60°C)  
Symbol Pressure W With internal opening indicator plate — 
0 Not provided
1 0.2 MPa
2 0.3 MPa ATEX directive compliance and connection
3 1.0 MPa ATEX directive category 2
Intrinsically safe explosion-proof item
X14 Air connection port: 1/4 NPT
Conduit connection port: M20 x 1.5
With blue cable gland

Accessories Note 1)
Applicable model
Symbol Accessories
IP8000-X14 IP8100-X14
Nil Without accessory  
A With ø0.7 output restrictor integrated pilot valve Note 2)  
B With ø1.0 output restrictor integrated pilot valve Note 2)  
C With fork lever type fitting M Note 3) — 
D With fork lever type fitting S Note 4) — 
E With lever unit for a 35 to 100 mm stroke Note 5)  —
F With lever unit for a 50 to 140 mm stroke Note 5)  —
G With compensation spring (A) Note 6)  
H With external scale plate — 
Note 1) If multiple accessories are required, they should be indicated in
alphabetical order.
ex. IP8100-010-AG
Note 2) “A” is applied to approx 90 cm3-capacity actuator.
“B” is applied to approx 180 cm3-capacity actuator.
Note 3) Fork lever-type fitting MX (Connection thread: M6 x 1) for
IP8100-00--X14.
Note 4) Fork lever-type fitting SX (Connection thread: M6 x 1) for
IP8100-00--X14.
Note 5) Standard lever is not attached.
Note 6) It is to be used together with “A” or “B” when tending to overshoot by the
use of “A” or “B”. It is mounted to the body as a replacement of the
standard compensation spring.
Note 7) Combination of “L” and “W” is not available.

All other specifications are the same as the standard products


Series IP8.
For details, refer to the WEB catalog or Series IP8
(CAT.ES60-18).

111
ATEX CompliantSmart Positioner
(Lever type/Rotary type)

Series 52-IP8001/8101
II 1 G Ex ia IIC T4/T5/T6 Ga
T4/T5: Ta = -20°C to 80°C T6: Ta = -20°C to 60°C

How to Order

ATEX Directive Intrinsically


Safe Explosion Proof 52 IP8 001 0 3 4
ATEX directive compliance ATEX temperature
ATEX directive category 1 ATEX Applicable model
52 Symbol
Intrinsically safe explosion-proof temperature IP8001 IP8101
Nil T4  
Type T6 T5/T6  
001 Smart lever type
101 Smart rotary type
Connection
Pressure gauge Note Symbol Air Electric
Pressure Applicable model Nil Rc1/4 G1/2
Symbol
gauge IP8001 IP8101
M Note) Rc1/4 M20 x 1.5
1 0.2 MPa  —
N Rc1/4 1/2NPT
2 0.3 MPa  —
1 1/4NPT G1/2
3 1.0 MPa  
2 Note) 1/4NPT M20 x 1.5
3 1/4NPT 1/2NPT
Specifications
4 G1/4 G1/2
Intrinsically safe explosion proof (ATEX)
4 5 Note) G1/4 M20 x 1.5
+ output function + HART communication
6 G1/4 1/2NPT
Note) When the symbol is M, 2, or 5
for 52- ATEX directive items, a
Accessories Note 1)
blue cable gland is included
Applicable model with the electrical connection.
Symbol Accessories
IP8001 IP8101
Nil None  
C With fork lever type fitting M — 
D With fork lever type fitting S — 
E For stroke 35 to 100 mm with lever unit Note 2)  —
F For stroke 50 to 140 mm with lever unit Note 2)  —
H With external scale plate — 
W Body with LCD window  
Note 1) If two or more accessories are required, the part numbers should be given in
alphabetical order.
ex. 52-IP8101-034-CH
Note 2) Standard lever is not attached.

All other specifications are the same as the standard products


Series IP8.
For details, refer to the WEB catalog or Series IP8
(CAT.ES60-18).

112
ATEX Compliant
Cylinder Positioner

Series 56-IP200/210
II 3GD T5...T6

How to Order

56 IP2 0 0
ATEX category 3 Temperature and Material
Nil Standard –5°C to 60°C
T High –5°C to 100°C
Model L Low –30°C to 60°C
0 Standard
Feedback spring and zero
1 Outside tube fixed to the main body S adjustment screw made in stainless steel

Stroke 25 to 300 mm

Specifications

Ambient temperature range


Low temp. model Standard model High temp. model
Classification
56-IP20--L 56-IP20- 56-IP20--T
II 3GD 100°C (T5) — — –5°C to 100°C
II 3GD 60°C (T6) –30°C to 60°C –5°C to 60°C —

Model 56-IP200/210
Supply pressure 0.3 to 0.7 MPa
Signal pressure 0.02 to 0.1 MPa
Port size Rc 1/4 (standard)
Pressure gauge port type Rc 1/8
Linearity Less than ± 2% F.S.
Hysteresis Less than 1% F.S.
Repeatability Less than 1% F.S.
Sensitivity Less than 0.5% F.S.
Air consumption 18 L/min (ANR) or less (SUP=0.5 MPa)
Flow rate 200 L/min (ANR) or more (SUP=0.5 MPa)
Applicable cylinder 50 to 300 bore sizes/25 to 300 mm stroke

Operating
–5°C to 60°C (Standard model)
−30°C to 60°C (Low temp. model)
temperature
−5°C to 100°C (High temp. model)
Note) Standard air temperature: 20°C, Absolute pressure: 101.3 kPa.
Relative humidity: 65%

All other specifications are the same as the standard products Series IP200.
For details, refer to the WEB catalog or Series IP200 (CAT.ES60).