Schneider Catalogo
Schneider Catalogo
 www.schneider-electric.com
Quick access to product information
Get technical information about your product
>>With just 3 clicks, you can reach the Industrial Automation              •	 Updated quarterly
  and Control catalogs, in both English and French
                                                                           •	 Embeds product selectors and configurators,
>>Download Digi-Cat with this link                                            360° images, training centers
                                                                           •	 Optimized search by commercial reference
>>Find the right Training for your needs on our Global website
>>Locate the training center with the selector tool, using this link
General contents
Companion software. . . . . . . . . . . . . . . . . 2
                                                                                                 10
             In this catalog, each time words which refer to Safety without precision, must be
             understood according to “Functional Safety”: IEC61508 & IEC61511.
                                                                                             1
Schneider Electric’s IoT-enabled, plug-and-play, open,
secure, interoperable architecture and platform, in Industries,
Infrastructures, Data Centers and Buildings.
Innovation at Every Level                                                                                  Dedicated architectures and IoT                                          Cybersecurity solutions                                     Enhanced safety
EcoStruxure is based on a three-tiered                                                                     We tailor our solutions in the form of dedicated                         Robust cybersecurity protection is a must, and              With the release of the M580 Safety, Schneider
technology stack delivering Innovation at Every                                                            reference architectures for plants:                                      Schneider Electric’s solutions can deliver it,              Electric further expands
Level, from Connected Products to Edge Control                                                             bb      Management systems                                               regardless of business type or industry.                    the EcoStruxure platform.
and Apps, Analytics and Services.                                                                                                                                                   The vendor-agnostic services provided by our                This consolidates our position as the most
                                                                                                           bb      Power systems
Together with our hybrid segments approach,                                                                                                                                         skilled professionals protect your entire critical          trusted industrial safety vendor, with
                                                                                                           bb      Data center systems                                                                                                          thousands of Modicon and Triconex safety
this enhances your value around safety,                                                                                                                                             infrastructure. We help to assess your risk,
reliability, operational efficiency, sustainability,                                                       bb      Industrial plant and machine systems                             implement cyber-specific solutions and maintain             systems protecting the most critical industrial
and connectivity on 6 domains of expertise:                                                                bb      Smart grid systems                                               your onsite defenses over time, while integrating           processes globally.
bb      Power                    bb      Plant                                                                                                                                      appropriate IT policies and requirements.
                                                                                                           The Industrial Internet of Things (IIoT) gives
bb      IT                       bb      Grid                                                              an additional boost to technologies. That's                              This is our difference and your advantage.
                                                                                                           why we provide to our customers IoT-enabled
bb      Building
                                                                                                           architecture and platform thus proposing simple,
bb      Machine                                                                                            reliable, productive and cost-efficient solutions.
                                                                                                                                                                                for Industry
                                                                                                                    Machinery                  Food & Beverage                  Water & Wastewater         Mining, Minerals & Metals             Oil & Gas
                          EcoStruxure™ Architecture
                               Apps,
                               Analytics &                                                                          AVEVA Software*                     EcoStruxure Machine Advisor       EcoStruxure Asset Advisor
                               Services                                                                                                                                                                                        EcoStruxure Augmented
                                                                                                      Engineering           Asset Performance           EcoStruxure Profit Advisor        EcoStruxure Power Advisor
                                                                                                                                                                                                                                  Operator Advisor
                                                                                                      Planning & Operations Monitoring and Control      EcoStruxure Control Advisor       EcoStruxure Resource Advisor
                                              End-to-end Cybersecurity
                               Edge
                               Control                                                                                                                                                                      EcoStruxure                            EcoStruxure
                                                                                                   Magelis lloT Box &                                             EcoStruxure        EcoStruxure                                   SCADA
                                                                                                                         PacDrive           Modicon                                                          Triconex                            Power Monitoring
                                                                                                     Industrial PC                                                Hybrid DCS         Foxboro DCS                                   Systems
                                                                                                                                                                                                           Safety System                             Expert
                               Connected
                               Products
                                                                                                                                             Sensors              Process                                                                              Okken &
                                                                                                       Magelis              Harmony                                               Tesys        Altivar         Preventa                Lexium
                                                                                                                                             & RFID           Instrumentaton                                                                        Blokset iPMCC
                *The Schneider Electric industrial software business and AVEVA have merged to trade as AVEVA Group plc, a UK listed company.
                The Schneider Electric and Life is On trademarks are owned by Schneider Electric and are being licensed to AVEVA by Schneider Electric.
10
     1/0
Contents   1 - EcoStruxure Control Expert
           software
                                                                                                                                                                               3
           vv Data editor................................................................................................ page 1/9
           vv DFB user function blocks.......................................................................... page 1/9
           vv Function block libraries........................................................................... page 1/12
           vv Debugging tools.......................................................................................page 1/11
           vv PLC simulator......................................................................................... page 1/12
           vv Trending tool........................................................................................... page 1/12                                               4
           vv Documentation editor............................................................................. page 1/12
           vv System Time stamping........................................................................... page 1/12
           vv D
               iagnostics integrated in Modicon M340, Modicon M580,
              Modicon M580 Safety, Premium and
              Quantum automation platforms.............................................................. page 1/13
                                                                                                                                                                               5
           vv Modifying the program with the PAC in RUN mode................................. page 1/14
           vv Cross-references function...................................................................... page 1/14
           vv Import/export function............................................................................. page 1/14
           vv Application converters............................................................................ page 1/15
           vv Operating system update utilities............................................................ page 1/15                                                          6
           vv Online modification of the configuration (CCOTF).................................. page 1/15
           vv Process control in machines................................................................... page 1/16
           vv Communication drivers........................................................................... page 1/18
           vv Upgrade kits for Concept, PL7 Pro and ProWORX software................... page 1/18                                                                              7
           vv Composition and Windows OS compatibility........................................... page 1/18
           vv EcoStruxure Control Expert update....................................................... page 1/19
           bb References............................................................................................ page 1/20
                                                                                                                                                                               8
           vv EcoStruxure Control Expert version 14 software .................................... page 1/20
           vv EcoStruxure Control Expert Small version 14 software........................... page 1/21
           vv EcoStruxure Control Expert Large version 14 software.......................... page 1/22
           vv EcoStruxure Control Expert Extra Large version 14 software................. page 1/23
           vv EcoStruxure Control Expert Extra Large Safety software....................... page 1/24
           vv Accessories for connecting to the PC programming terminal.................. page 1/25                                                                            9
10
                                                                                                                                                                  1/1
     Selection guide                                               Software
                                                                   EcoStruxure Control Expert software
                                                                   Versions u V14
     EcoStruxure Control Expert programming software for Modicon M340 M, Modicon M580 M5, Modicon M580 Safety M5S, Modicon                  EcoStruxure Control Expert programming software for Modicon M340 M , Modicon M580 M5, Modicon M580 Safety M5S, Modicon
     Momentum MM, Premium P, Quantum Q, Quantum Safety QS and Modicon distributed I/O D platforms                                           Momentum MM, Premium P, Quantum Q, Quantum Safety QS and Modicon distributed I/O D platforms
2    services     event-triggered)
                  Multitask programming (Master, fast, auxiliary                                      M5                                    M5 - P (TSXP575•) - Q (140CPU651/671) - D                                                                                      2
                  and event-triggered)
                  Functional view and function modules             M - MM - D                         M - M5 - MM - P - Q - D               M - M5 - MM - P - Q - D
                  Program Units                                    M                                  M - M5                                M - M5
                  DFB editor and instances                         M - MM - D                         M - M5 - MM - P - Q - D               M - M5 - MM - P - Q - D
                  DDT compound data editors                        M - MM - D                         M - M5 - MM - P - Q - D               M - M5 - MM - P - Q - D
7                                                                                                                                                                                                                                                                          7
                 Online modification of the configuration                                             M5 - Q                                M5 - Q
                 Online modification of the program                M - MM - Q                         M - M5 - MM - P - Q                   M - M5 - MM - P - Q
                 Importing of applications (Modsoft, Concept,      M - MM                             M - MM - Q                            M - M5 - MM - Q
                 ProWORX) written in LL984 language
                 Data dictionary, Dynamic exchange with            M - MM - D                         M - M5 - MM - P - Q - D               M - M5 - P - Q - D
                 SCADA through OFS
                 Static exchange via XML/XVM export files          M - MM - D                         M - M5 - MM - P - Q - D               M - M5 - MM - P - Q - D
     Compatible Modicon M340 CPUs M                                All models                         All models                            All models
8    Modicon
     platforms
                 Modicon M580 CPUs M5                              –                                  BMEP5810/5820/5830/BMEH5820           All models                                                                                                                     8
                 Modicon M580 Safety CPUs M5S                      –                                  BMEP582040S/BMEH582040S (with M580    All models (with M580 Safety Add On CEXADSSCZZ•PMZZ)
                                                                                                      Safety Add On CEXADSSCZZ•PMZZ)
                  Modicon Momentum CPUs MM                         171CBU78090/98090/98091            171CBU78090/98090/98091               171CBU78090/98090/98091
                  Premium CPUs P                                   –                                  TSXP57104M/1634M/154M                 All models
                                                                                                      TSXP57204M/2634M/254M
                                                                                                      TSXP57304M/3634M/354M
9                                                                                                     TSXP574634/454M
                                                                                                      TSXH5724/44M
                                                                                                                                                                                                                                                                           9
                  Quantum CPUs Q                                   –                                  140CPU31110, 140CPU43412U,            All models
                                                                                                      140CPU53414U
                Quantum Safety CPUs S                              –                                  –                                     –
     Compatible Modicon distributed I/O D                          STB, OTB, TM7, ETB, Momentum       STB, OTB, TM7, ETB, Momentum          STB, OTB, TM7, ETB, Momentum
10   Software name                                                 EcoStruxure Control Expert Small   EcoStruxure Control Expert Large      EcoStruxure Control Expert Extra Large                                                                                         10
     Unity Pro package                                             CEXSPUCZS•PMZZ                     CEXSPUCZL•PMZZ                        CEXSPUCZX•PMZZ
     License, see page                                             1/21                               1/22                                  1/23
      1/2                                                                                                                                                                                                                                                            1/2
                                                                                                                                                                                                                                                                     1/3
     Selection guide                                       Software
                                                           EcoStruxure Control Expert software
                                                           XL with M580 Safety
                                                           Unity Pro V7 XL Safety for Quantum
     EcoStruxure Control Expert programming software for Modicon M340 M, Modicon M580 M5, Modicon M580 Safety M5S, Modicon Momentum MM,   Unity Pro programming software for Modicon M340 M , Modicon M580 M5, Modicon M580 Safety M5S, Modicon Momentum MM, Premium P,
     Premium P, Quantum Q, Quantum Safety QS and Modicon distributed I/O D platforms                                                      Quantum Q, Quantum Safety QS and Modicon distributed I/O D platforms
2    services     event-triggered)
                  Multitask programming (Master, fast, auxiliary M5 - M5S - P (TSXP575•) - Q (140CPU651/671) - D                          P (TSXP575•) - D - Q (140CPU651/671)                                                                                                  2
                  and event-triggered)
                  Functional view and function modules           M - M5 - M5S - MM - P - Q - D                                            M - MM - P - D - Q - QS
                  Program Units                                  M - M5 - M5S
                  DFB editor and instances                       M - M5 - M5S - MM - P - Q - D                                            M - MM - P - D - Q - QS
                  DDT compound data editors                      M - M5 - M5S - MM - P - Q - D                                            M - MM - P - D - Q
4                                                                                                                                                                                                                                                                               4
                  Hot Standby PLC redundancy system              P (TSXH5724M/44M) - Q (140CPU67160) - D                                  P (TSXH5724M/44M) - D -Q (140CPU67160)
                  System and Application diagnostics             M - M5 - M5S - MM - P - Q - D                                            M - MM - P - D - Q - QS
                  Bus and network configuration to slave devices M - M5 - M5S - MM - P - Q - D                                            M - MM - P - D - Q
                  (Modicon distributed I/O, etc.)
     Debugging PLC simulator                                     M - M5 - M5S - MM - P - Q - D                                            M - MM - P - D - Q - QS
     and display Hypertext link animations in graphic            M - M5 - M5S - MM - P - Q - D                                            M - MM - P - D - Q - QS
     services     languages
                  Step by step execution, Breakpoint,            M - M5 - M5S - MM - P - Q - D                                            M - MM - P - D - Q - QS
5                 Watchpoint
                  Trending tool                                  M - M5 - M5S - MM - P - Q - D                                            M - MM - P - D - Q - QS
                                                                                                                                                                                                                                                                                5
                  Operator screens, Animation tables             M - M5 - M5S - MM - P - Q - D                                            M - MM - P - D - Q - QS
                  Diagnostics viewer                             M - M5 - M5S - MM - P - Q - D                                            M - MM - P - D - Q - QS
     Other        Creation of hyperlinks                         M - M5 - M5S - MM - P - Q - D                                            M - MM - P - D - Q - QS
     services     XML/XVM import/export                          M - M5 - M5S - MM - P - Q - D                                            M - MM - P - D - Q - QS
                  Application converters (Modsoft, Concept,      M - M5 - M5S - MM - P - Q - D                                            M - MM - P - D - Q
6                 ProWORX, PL7)
                  Utilities for updating PACs and Advantys       M - M5 - M5S - MM - P - Q - D                                            M - MM - P - D - Q
                                                                                                                                                                                                                                                                                6
                  operating system
                  Communication drivers for Modicon platforms    M - M5 - M5S - MM - P - Q - D                                            M - MM - P - D - Q - QS
                  Unity Pro servers - Openness (OFS,             M - M5 - M5S - MM - P - Q - D                                            M - MM - P - D - Q - QS
                  3rd party tools)
                  Online modification of the configuration       M5 - M5S - Q
8                                                                                                                                                                                                                                                                               8
     Modicon      Modicon M580 CPUs M5                           All models                                                               –
     platforms
                  Modicon M580 Safety CPUs M5S                   All models                                                               –
                  Modicon Momentum CPUs MM                       171CBU78090/98090/98091                                                  171CBU78090/98090/98091
                  Premium CPUs P                                 All models                                                               TSXP57104M/1634M/154M          TSXP574634M/454M
                                                                                                                                          TSXP57204M/2634M/254M          TSXP575634M/554M
                                                                                                                                          TSXP57304M/3634M/354M          TSXP576634M
                                                                                                                                                                         TSXH5724M/44M
                  Quantum CPUs Q                            All models                                                                    140CPU31110                    140CPU65150/60
9                                                                                                                                         140CPU43412U
                                                                                                                                          140CPU53414U
                                                                                                                                                                         140CPU65260
                                                                                                                                                                         140CPU67160
                                                                                                                                                                                                                                                                                9
                                                                                                                                                                         140CPU67260/61
                  Quantum Safety CPUs S                     –                                                                             140CPU65160S,
                                                                                                                                          140CPU67160S
     Compatible Modicon distributed I/O D                   STB, OTB, TM7, ETB, Momentum                                                  STB, OTB, TM7, ETB,
                                                                                                                                          Momentum
10   Software name                                          EcoStruxure Control Expert Extra Large with M580 Safety                       Unity Pro Extra Large Safety v7.0 for Quantum                                                                                         10
     Unity Pro package                                      CEXSPSCZX•PMZZ                                                                UNYSPUX••V1X
     License, see page                                      1/24                                                                          –
      1/3
      1/4                                                                                                                                                                                                                                                                 1/3
                                                                                                                                                                                                                                                                          1/5
     Presentation,                     Software
     functions                         EcoStruxure Control Expert software
                                       Small/Large/Extra Large/Extra Large with M580 Safety
                                       Presentation
                                       This catalog describes EcoStruxure Control Expert software version 14, which is
                                       the latest version available.
2                                      EcoStruxure Control Expert is the common programming, debugging and operating
                                       software for the Modicon M340, M580, M580S, Premium, Momentum and Quantum
                                       ranges.
                                       Note: Please, use Unity Pro software V7 for Quantum SIL3 (safety integrity level 3).
     EcoStruxure Control Expert        EcoStruxure Control Expert is multitasking software offering the following features:
3                                      bb All-in-one software
                                       bb Five IEC 61131-3 programming languages
                                       bb LL 984 programming language
                                       bb Device integration with FDT/DTM standard
                                       bb Integrated, customizable DFB library
                                       bb PLC simulator on PC for program validation prior to installation
                                       bb Built-in tests and diagnostics
                                       EcoStruxure Control Expert supports the new M580 Safety PACs, mixing process
                                       and safety in a single project. It allows to:
                                       bb Optimize engineering time
                                       bb Simplify programming with IEC61508 functions
5 bb Facilitate maintenance
             ur
          Sec ity                      Cybersecurity
                                       Schneider Electric constantly endeavours to maintain the security of its systems.
                                       Security guidelines are available for our customers to ensure their systems are
                                       protected from attack.
6                                      With the Modicon M340, M580, M580S, Premium, Momentum and Quantum
                                       automation platforms:
                                       bb Protection against remote programming changes via a password
                                       bb Option to enable or disable HTTP or FTP services
                                       FDT/DTM function
8                                      EcoStruxure Control Expert facilitates integration of fieldbus architectures into
                                       engineering control systems using FDT/DTM technology:
                                       bb FDT (Field Device Tool) is the container which supports the device DTMs.
                                       bb DTM (Device Type Manager) is the configuration tool for devices with integrated
                                       graphic interfaces. It contains the properties specific to each device.
     DTM editor (Modicon STB island)
                                       In addition to the FDT/DTM standard, Unity Pro uses specific information from the
9                                      Master DTM created for the Profibus Remote Master (PRM) module, the HART
                                       module, the Premium ISPY101 weighing module, Altivar process drive integration and
                                       the Modbus/TCP and EtherNet/IP network modules BMXNOC0401 and BMENOC03p1.
                                       Use of the Master DTM allows EcoStruxure Control Expert to perform the following
                                       actions:
                                       bb Manage the PAC I/O scan
10                                     bb Create the application variables based on the description of the process objects
                                       available from the connected DTM devices
                                       bb Manage synchronization with the PAC configuration
     DTM hardware catalog              bb Create a generic DTM from the description files (GSD or EDS)
     Selection guide:
     page 1/2
       1/6
Functions (continued)              Software
                                   EcoStruxure Control Expert software
                                   Small/Large/Extra Large/Extra Large with M580 Safety
                                   DTM Audit Tool is provided to have a clear vision of the DTM versions embedded in
                                   a project and the versions installed on the PC. Depending on the DTM versions
                                   compatibility, the tool informs if the project can be opened and built.                   4
                                   Programming languages
                                   The five IEC 61131-3 compliant languages
                                   The five graphical or textual languages available in EcoStruxure Control Expert are
                                   used for programming Modicon M340, Modicon M580, Modicon M580 Safety,
DTM Audit Tool screen              Modicon Momentum, Premium and Quantum automation platforms.                               5
                                   The three graphical languages are:
                                   bb Ladder (LD) language
                                   bb Function Block Diagram (FBD)
                                   bb Sequential Function Chart (SFC) or Grafcet
                                   For these five languages, you can use the standard set of instructions compliant with
                                   IEC standard 61131-3 to create applications which can be transferred from one
                                   platform to another. EcoStruxure Control Expert software also provides extensions
                                   to this standard set of instructions. As they are specific to Modicon M340, Modicon
                                   M580, Modicon M580 Safety, Modicon Momentum, Premium and Quantum
                                                                                                                             7
                                   automation platforms, these extensions support the development of more complex
                                   applications in order to maximize the potential of the specific features of each of
                                   these platforms.
                                   LL984 language
                                   LL984 (Ladder Logic 984) language enables migration from legacy Modicon ranges.           8
                                   It is used to program Modicon M580, Modicon M580 Safety, Modicon M340,
FBD language editor                Momentum and Quantum automation platforms.
10
Selection guide:
page 1/2
                                                                                                                       1/7
     Functions (continued)   Software
                             EcoStruxure Control Expert software
                             Small/Large/Extra Large/Extra Large with M580 Safety
                             Program units
                             Program Units are compliant with Program Organization Units (POUs) as defined in
1                            IEC1131-3 standard.
                             Program Units are autonomous programming entities (only available for Modicon
                             M580 and M340). Program Units allows easy duplication and clear organization of
                             program with local and public variables.
              -m
         m
          e-to ark           Common Safety on Modicon M580 (1)
4
                              Presentation
                   et
     Ti
6
                             All X80 safety I/O are managed through safety tasks, and standard and non
                             interfering X80 modules are managed in other tasks. So the mix of safety and
                             standard X80 modules is possible in the same M580 Safety PAC.
                              Data editor
                             Process and safe data are managed in distinct M580 memory area. EcoStruxure
8                            Control Expert allows to easily manage:
                             bb Exchange of data between process and safe areas of the project in “Data Editor”
                             bb Process data in “Process Data Editor”
                             bb Safe data in “Safe Data Editor”
9    Safety function block   EcoStruxure Control Expert supports new M580 Safety offers with IEC61508
                             programming languages and rich library of Safety Function blocks.
10
     Selection guide:
     page 1/2
       1/8
Functions (continued)    Software
                         EcoStruxure Control Expert software
                         Small/Large/Extra Large/Extra Large with M580 Safety
                         Data editor
                         The data editor provides a single tool for performing the following editing tasks:
                         bb Declaration of data including variables and function blocks (declaration of their
                         type, instances and attributes)
                                                                                                                 1
                         bb Use and archiving of function block data types in different libraries
                         bb Hierarchical view of data structures
                         bb Searching, sorting and filtering of data
                         bb Creation of a hyperlink to access a description from any variable comment
Data editor
                         The data is displayed in four tabs:
                         bb “Variables” tab for the creation and management of the following data instances:
                                                                                                                 2
                         bits, words, double words, inputs/outputs, tables and structures
                         bb “DDT Types” tab for the creation of derived data types (tables and structures)
                         bb “Function Blocks” tab for the declaration of EFBs and DFBs
                         bb “DFB Types” tab for the creation of DFB user function block data types
                         The data editor columns can be configured (number of columns, order). The
                         attributes associated with a variable can be displayed in a properties window.
Data properties
                         This editor can be accessed at any time during programming by selecting variables
                         for data modification or creation.
                                                                                                                 4
                                                                                                                 7
                         bb facilitates program debugging (variables handled by the DFB are identified in the
                         data editor)
                         bb enables the use of private variables specific to the DFBs, which are independent
                         of the application
                                                                                                                 8
                         public and private internal variables) and a comment to it via the data editor.
                         bb The code is created in one or more sections of the program, with the following
                         languages selected according to requirements: Structured Text, Instruction List,
                         Ladder or Function Block Diagram (ST, IL, LD or FBD).
                         bb The DFB can be stored in a library with an associated version number.
                         bb A DFB instance is created in the data editor or when the function is called in the
                         program editor.
                         bb This instance is used in the program in the same way as an EFB (the instance can
Use within the program   be created from within the program).                                                    9
10
Selection guide:
page 1/2
                                                                                                           1/9
     Functions (continued)               Software
                                         EcoStruxure Control Expert software
                                         Small/Large/Extra Large/Extra Large with M580 Safety
                                         The “Base Lib” library, which covers standard automation functions, is supplemented
                                         by other, more application-specific libraries and platform-specific functions:
                                         bb Communication library, providing an easy means of integrating communication
4                                        programs from PACs with those used by HMIs from the PAC application program.
                                         Like other function blocks, these EFBs can be used in any language to exchange
                                         data between PACs or to deliver data to be displayed on an HMI.
                                         bb Process control library. The CONT_CTL library can be used to set up process-
                                         specific control loops. It offers controller, derivative and integral control functions and
                                         additional algorithms, such as EFBs for calculating mean values, selecting a
                                         maximum value, detecting edges or assigning a hysteresis to process values, etc.
5                                        bb Diagnostics library, which can be used to monitor actuators and contains EFBs
                                         for active diagnostics, reactive diagnostics, interlocking diagnostics, permanent
                                         process condition diagnostics, dynamic diagnostics, monitoring of signal groups, etc.
                                         bb I/O management library, providing services to handle information exchanged
                                         with hardware modules (formatting data, scaling, etc.).
                                         bb Motion Function Blocks library, containing a set of predefined functions and
                                         structures to manage motion controlled by drives and servo drives connected on
6                                        CANopen.
                                         bb Motion library for motion control and fast counting.
                                         bb System library, which provides EFBs for the execution of system functions,
                                         including: evaluation of scan time, availability of several different system clocks, SFC
                                         section monitoring, display of system status, management of files on the memory
                                         cartridge of the Modicon M340 processor, M580 processor, etc.
                                         bb Finally, a library named “obsolete”, containing the function blocks used by legacy
7                                        programming software needed to perform application conversions.
10
     Selection guide:
     page 1/2
      1/10
Functions (continued)                           Software
                                                EcoStruxure Control Expert software
                                                Small/Large/Extra Large/Extra Large with M580 Safety
                                                Debugging tools
                                                EcoStruxure Control Expert software offers a complete set of tools for debugging
                                                Modicon M340, M580, M580S, Momentum, Premium or Quantum applications. A
                                                tool palette provides direct access to the main functions:
                                                                                                                                        1
                                                bb Dynamic program animation.
                                                bb Setting of watchpoints or breakpoints (not authorized in event-triggered tasks).
                                                bb Step-by-step program execution. A function in this mode enables section-by-
                                                section execution. Instruction-by-instruction execution can be launched from the
                                                previous breakpoint. Three execution commands are therefore possible when the
                                                element to be processed is a subroutine (SR) or DFB user block instance:
                                                vv Step Into: this command is used to move to the first element of the SR or DFB
                                                                                                                                        2
Debugging tools: Dynamic animation/adjustment   vv Step Over: this command is used to execute the entire SR or DFB
                                                vv Step Out: this command is used to move to the next instruction after the SR or
                                                DFB element
                                                bb Independent execution of the master (MAST), fast (FAST), auxiliary (AUX) and
                                                event-triggered (EVTi) tasks.
                                                EcoStruxure Control Expert can be used to save, import and export Animation
                                                                                                                                        5
                                                tables with predefined set values. As it allows population of set values along with
                                                current values and vice versa in the PAC, the Animation tables can be used as
                                                templates to make the application easier to tune.
10
Selection guide:
page 1/2
                                                                                                                                 1/11
     Functions (continued)                Software
                                          EcoStruxure Control Expert software
                                          Small/Large/Extra Large/Extra Large with M580 Safety
PLC simulator
1
                                          EcoStruxure Control Expert ’s integrated simulator can be used to test the
                                          application program for Modicon M340, M580, M580S, Momentum, Premium or
                                          Quantum automation platforms from the PC terminal without having to connect to the
                                          processor. The functions provided by the debugging tools are available for
     Simulator control panel              debugging the master, fast and auxiliary tasks.
                                          As the simulator does not manage the PLC I/O, animation tables can be used to
                                          simulate the state of inputs by forcing them to 0 or 1.
2
                                          The simulator can be connected to third-party applications via an OPC server with
                                          OFS (OPC Factory Server) software.
                                          Trending tool
                                          The trending tool allows easy monitoring of variables by detecting operating
                                          problems or improving process performance. You can select any variable in your
3                                         application and start acquisition, save records, and analyze records with integrated
                                          tools or Excel. The PAC mast scan can scan up to 16 variables.
                                          Documentation editor
                                          The documentation editor is based on the Documentation Browser, which shows the
                                          file structure in tree form.
5                                         It allows all or part of the application file to be printed on any graphics printer
                                          accessible under Windows and using True Type technology, in A4 or US letter print
                                          format.
                                          The documentation editor supports the creation of user-specific files using the
                                          following headings:
                                          bb Title page
                                          bb Contents
6                                         bb General information
                                          bb Footer
                                          bb Configuration
                                          bb EF, EFB and DFB type function blocks
     Accessing the documentation editor   bb User variables
                                          bb Communication
                                          bb Project structure
7
                                          bb Program
                                          bb Animation tables and cross-references
                                          bb Runtime screens
10
     Selection guide:
     page 1/2
      1/12
Functions (continued)                                        Software
                                                             EcoStruxure Control Expert software
                                                             Small/Large/Extra Large/Extra Large with M580 Safety
                                                             Integrated diagnostics
 Diagnostics integrated in Modicon M340, Modicon M580, Modicon M580 Safety, Premium and Quantum
 automation platforms
 Presentation                                                                                                                                                      1
System diagnostics                                            Diagnostics viewers
                                                                                                                     Vijeo Citect
                                                                                                                     Thin client Magelis iPC     Higher-level
                                                                                                                                                 M.E.S.
                                                                                                                                                                   2
    Processor             In-rack I/O         Distributed
    for system            modules             I/O modules
    bits and                                  on Ethernet                                                                    Ethernet TCP/IP
    words                                     or I/O buses
                                                                                                                     Vijeo Designer
                                                                                                                                               Cell level          3
Application diagnostics
Magelis Terminal
                                                                                                                                                                   4
                                                                  RUN      ERR
I/O MB1
                                                                  ETH      ETH
                                                                  100      STS
                                                                  ETH LNK/ACT
                                                                                 Quantum,Premium, M340,
                                                                                 M580, M580S, Momentum                                         Machine level
                                                                                                                      EcoStruxure
                                                                                                          PC          Control Expert
                                                             The diagnostics offer for Modicon M340, M580, M580S, Momentum, Premium and
                                                                                                                                                                   5
                                                             Quantum platforms is based on the following three components:
                                                             bb System diagnostics
                                                             bb DFB and EFB diagnostic function blocks (for system and application diagnostics)
                                                             bb Error message display system, called viewers, supplied as a standard component
                                                             of Magelis terminal, Vijeo Citect supervisory software and EcoStruxure Control
                                                             Expert setup software
                                                                                                                                                                   6
 System diagnostics
                                                             The system diagnostics for the Modicon M340, M580, M580S, Momentum, Premium
                                                             and Quantum platforms support the monitoring of system bits/words, I/O modules and
                                                             activity times (minimum/maximum) of SFC steps. By simply choosing the relevant
                                                             option during application configuration, any event will generate time-stamped
                                                             messages logged in the diagnostic buffer of the PAC.
                                                             These events are displayed automatically in a diagnostics viewer (1) without requiring                7
                                                             any additional programming.
                                                             With EcoStruxure Control Expert integrated diagnostics, this function can be used
                                                             to perform first-level diagnostics of the elements in the configuration, up to and
                                                             including each I/O module channel.
Configuration level
                                                                                                                                                                   9
                                                             Module level
                                                                                                                                                            1/13
     Functions (continued)       Software
                                 EcoStruxure Control Expert software
                                 Small/Large/Extra Large/Extra Large with M580 Safety
                                 This function makes it possible to add or modify program code and data in different
                                 parts of the application during a single modification session (thus resulting in a
                                 uniform, consistent modification with respect to the controlled process). This
                                 increased flexibility comes at a cost in terms of the amount of program memory
3                                required.
                                 Cross-references function
                                 EcoStruxure Control Expert 's cross-references function, which is available in
                                 standalone mode (offline) and when connected to the PAC in Run (online), allows
                                 users to view the elements of a PAC application when searching for any type of
4                                variable. This view indicates where the declared variable is used, as well as how it is
                                 used (for writing, reading, etc.).
                                 This function also provides access to the Search/Replace function for variable
                                 names.
                                 The variable search can be initialized from any editor (language, data, runtime
     Cross-references table      screen, animation table, etc.).
5
                                 Import/export function
                                 The import/export function available in EcoStruxure Control Expert supports the
6
                                 following operations from the structural and functional project views:
                                 bb Via the import function, reuse of all or part of a previously created project in the
                                 current project.
                                 bb Via the export function, copying of all or part of the current project to a file for
                                 subsequent reuse.
                                 The files generated during export are generally in XML format (1). However, in
     Data export shortcut menu   addition to XML, variables can be exported and imported in the following formats:
7                                bb .xvm format compatible with OFS data server software
                                 bb source format, in an .scy file compatible with PL7 development software
                                 bb text format with separator (TAB) in a .txt file for compatibility with any other system
                                 During an import, a wizard can be used to reassign data to new instances of:
                                 bb DFB function blocks
                                 bb DDT data structures
8                                bb simple data
                                 In addition, when a functional module is imported, the data associated with
                                 animation tables and runtime screens is also reassigned.
                                 EcoStruxure Control Expert includes an Excel import/export tool that makes it easy
                                 to manage the variables using an XML export file in Excel.
10                               (1) XML language is an open, text-based language that provides structural and semantic
                                      information.
     Selection guide:
     page 1/2
      1/14
Functions (continued)                   Software
                                        EcoStruxure Control Expert software
                                        Small/Large/Extra Large/Extra Large with M580 Safety
                                        Application converters
                                        EcoStruxure Control Expert ’s integrated conversion tools can be used to convert
                                        applications created with ModSoft, ProWorX, Concept and PL7 programming
                                        software to EcoStruxure Control Expert applications.
                                                                                                                                       1
                                        Concept/EcoStruxure Control Expert converter (Quantum and Momentum PACs)
                                        This conversion is performed with a Concept application V2.5 or later (it can also be
                                        performed in V2.11 or later, but only after an update to V2.5). In order to perform the
                                        conversion, the application should be exported to an ASCII file in Concept.
                                        The export file is converted to a EcoStruxure Control Expert source file                       2
                                        automatically. This file is then analyzed by EcoStruxure Control Expert . At the end of
                                        the procedure, a conversion report is generated and an output window displays any
                                        conversion detected error and provides direct access to the part of the program to be
                                        modified.
                                        The Concept application converter converts the application to EcoStruxure Control
                                        Expert , but does not guarantee that it will operate correctly in real time. It is therefore
                                        essential to test or debug all converted applications.                                         3
                                        PL7/EcoStruxure Control Expert converter (Premium PAC and Atrium slot PAC)
                                        This conversion is performed with a PL7 application V4 or later (Premium PAC or
                                        Atrium slot PAC). In order to perform the conversion, the source file (complete
                                        application or user function block) should be exported to PL7.
                                        The conversion procedure is similar to that of the Concept conversion described above.
                                        Note: Applications created with Concept, Modsoft and ProWORX can be converted to LL984.
                                                                                                                                       4
                                        Please contact our Customer Care Center
                                                                                                                                       10
                                        On Quantum, the CCOTF function is supported by standalone processors for
                                        the three types of I/O architecture (local, RIO, DIO) using version 5 of EcoStruxure
                                        Control Expert , and for Hot Standby processors using version 4.1 or higher
                                        of EcoStruxure Control Expert . The CCOTF function should first be validated in
                                        the EcoStruxure Control Expert configuration screen. A confirmation screen appears
Configuration screen                    when the configuration has been modified online.
                                                                                                                             1/15
     Functions (continued)                                                  Software
                                                                            EcoStruxure Control Expert software
                                                                            Small/Large/Extra Large/Extra Large with M580 Safety
                                                                            Programmable process control
                                                                            The requirements for closed loop control functions in machines are adequately met
                                                                            by Modicon M340, Modicon M580, Modicon M580 Safety, Modicon Momentum,
                                                                            Premium and Quantum platforms thanks to the wealth of functions in the library and
                                                                            the flexibility with which function blocks can be linked together through programming.
                                                                            This solution therefore avoids the need for external controllers and simplifies the
2                                                                           overall control architecture of the machine, as well as its design, roll-out and
                                                                            operation.
                                                                            The EFs or EFBs can be used in any of the EcoStruxure Control Expert languages
                                                                            (LD, ST, IL and FBD). FBD is particularly suitable for accessing control processing
                                                                            operations in EcoStruxure Control Expert through its wizard for entering and viewing
     CONT_CTL, programmable process control integrated in
                                                                            parameters and function block variables.
3
     Unity Pro
4
                                                                            bb process value processing
                                                                            bb output value processing
                                                                            bb setpoint management
5                                                                           LAG_FILTER
                                                                            LDLG
                                                                                                        First order time lag
                                                                                                        Lead/lag function with smoothing
                                                                            LEAD                        Lead function with smoothing
                                                                            MFLOW                       Mass flow calculation based on the measurement of differential
                                                                                                        pressure or flow speed with pressure and temperature
                                                                                                        compensation
                                                                            QDTIME                      Dead time term
6                                                                           SCALING                     Scaling
                                                                            TOTALIZER                   Integrator (typically of flow) until a limit (typically a volume) is
                                                                                                        reached, with automatic reset
                                                                            VEL_LIM                     Velocity limiter, with manipulated variable limiting
                     AUTOTUNE                       PIDFF
        TT18_PV   PV                                     OUTD
                                                                            Controllers
                            PV_O                PV
        TT18_SP   SP        SP_O                SP                          PI_B                        Basic PI controller: PI algorithm with a mixed structure
7
       TC18_OUT   RCPY    PARA_C    TC18_PARA   FF
     TC18_START   START              TC18_OUT   RCPY                                                    (series/parallel)
      TC18_PREV   PREV                      1   MAN_AUTO MA_O
        TC_PARA   PARA                          PARA      INFO              PIDFF                       Complete PID controller: PID algorithm with a parallel or mixed
                  TR_I
                  TR_S
                              TRI               TR_I
                                                TR_S
                                                        STATUT                                          structure (series/parallel)
                             TRS
                            INFO     TC2_OUT    OUT        OUT   TC2_OUT    AUTOTUNE                    Automatic tuner setting for the PIDFF (complete PID) controller or
                          STATUS
                                                                                                        the PI_B (simple PI) controller
                                                     MS                                                 v	 Identification using Ziegler Nichols type method
                                     TC2_OUT    IN
                                                FORC
                                                                                                        v	 Modeling based on first-order process
                                                                                                        v	 Building of control parameters with criterion for prioritizing
8
                                                MA_FORC
                                                MAN_AUTO OUTD
                                                PARA
                                                                                                            either the reaction time to disturbance (dynamic) or the stability
                                                         MA_O
                                                TR_I    STATUT                                              of the process
                                                TR_S
                                    TC18_OUT    OUT        OUT   TC18_OUT   IMC                         Model-based controller. The model is a first-order model with
                                                                                                        delay. This corrector is useful:
     Example: PID controller with MS manual control                                                     v	 When there are serious delays compared with the main time
                                                                                                            constant of the process; this scenario cannot be satisfactorily
                                                                                                            resolved by standard PID process control.
                                                                                                        v	 For regulating a non-linear process IMC can handle any stable
9                                                                           SAMPLETM
                                                                                                            aperiodic process of any order.
                                                                                                        Control of controller startup and sampling
                                                                            STEP2                       Simple two-position controller
                                                                            STEP3                       Three-position controller for temperature regulation
                                                                            Mathematical functions
                                                                            COMP_DB                     Comparison of two values, with dead zone and hysteresis
10
                                                                            K_SQRT                      Square root, with weighting and threshold, useful for linearization
                                                                                                        of flow measurements
                                                                            MULDIV_W                    Weighted multiplication/division of 3 numerical values
                                                                            SUM_W                       Weighted summing of 3 numerical values
     Selection guide:
     page 1/2
       1/16
Functions (continued)                                       Software
                                                            EcoStruxure Control Expert software
                                                            Small/Large/Extra Large/Extra Large with M580 Safety
                                                            Programmable process control
                                                            SAH
                                                            HYST_XXX
                                                                                         Detection of a rising edge
                                                                                         Detection of high threshold with hysteresis (1)
                                                                                                                                                                  2
                                                            INDLIM_XXX                   Detection of high and low thresholds with hysteresis (1)
                                                            RATIO
                                                            SP_SEL
                                                                                         Ratio controller
                                                                                         Selection of setpoint value: local (operator) or remote (processing)     4
                                                                                                                                                                  5
                                                            EcoStruxure Control Expert is a programming language particularly suitable for
                                                            building control loops.
                                                            Designers can use FBD to easily associate blocks from the CONT_CTL library with
                                                            their own DFBs written in EcoStruxure Control Expert ’s ST, IL or LD language, or in
                                                            C language.
                                                             Debugging, operation
                                                            All EcoStruxure Control Expert ’s standard debugging services (see page 1/11) are
                                                            available. In particular, the PLC simulator can be used to check correct execution of                 6
                                                            processing offline.
                                                             Compatibility
                                                            The CONT_CTL control function block library is available in all versions of
                                                            EcoStruxure Control Expert . It is compatible with processors in the Modicon M340,
                                                            Modicon M580, Modicon M580 Safety, Modicon Momentum, Premium and Quantum                              7
                                                            ranges.
                                                                                                                                                                  8
Programming in online mode                                  controller, HVAC and mass flow calculation (see page 2/8).
                                                             Resources
                                                            The technical documentation provides many examples of how to set up
                                                            programmable process control function blocks in FBD, LD, IL and ST languages.
                                                            The techniques for adjusting process control loops are described in the document
                                                            “Process control, Unity V3.0” available online at www.schneider-electric.com.
                                                                                                                                                                  9
                                                            (1) XXX according to the type of variable: DINT, INT, UINT, UDINT, REAL.
10
Selection guide:
page 1/2
                                                                                                                                                         1/17
     Functions (continued)   Software
                             EcoStruxure Control Expert software
                             Small/Large/Extra Large/Extra Large with M580 Safety
                             Communication drivers
                             The most commonly used communication drivers for Modicon M340, M580, M580S,
1                            Momentum, Premium and Quantum platforms are installed at the same time as the
                             EcoStruxure Control Expert software.
                             EcoStruxure Control Expert also includes the following drivers, which can be
                             installed as required (1):
                             Protocol - Hardware                 Windows® 7                   Windows® 10
2
                                                                 32-bit and 64-bit editions   32-bit and 64-bit editions
                             Fip adaptor - CUSBFIP
                             Modbus Serial - COM port
                             PCIway - Atrium TPCI57 PCI card
                             Uni-Telway - COM port
                             USB for high end PLC
                             These upgrades are only available for licenses of the same type (e.g. from Concept
                             XL group license to EcoStruxure Control Expert Extra Large group license).
Note: EcoStruxure Control Expert requires .NET Framework 3.5 and .NET Framework 4.5.2.
                             They include:
                             bb Documentation in electronic format in six languages (English, French, German,
7                            Italian, Spanish and Chinese)
                             bb Converters for converting applications created with Concept, PL7 and Unity M580
                             application converter (UMAC) programming software
                             bb PLC simulator
                             Cables for connecting the processor to the programming PC need to be ordered
                             separately.
10
     Selection guide:
     page 1/2
      1/18
Functions (continued)   Software
                        EcoStruxure Control Expert software
                        Small/Large/Extra Large/Extra Large with M580 Safety
                        Note: The latest firmware versions can be downloaded from our website
                               www.schneider-electric.com.                                                5
10
Selection guide:
page 1/2
                                                                                                   1/19
     References                   Software
                                  EcoStruxure Control Expert software
                                  Small/Large/Extra Large/Extra Large Safety
2                                  Package is unique
                                  Package is now unique for all sizes (Small, Large, Extra Large and Safety).
                                  Unity Pro XLS becomes EcoStruxure Control Expert with M580 Safety
4                                 M580 Safety can now be managed in different ways:
                                  bb With an Add-on license that can be added to a XL or L license (see page 1/24); or
                                  bb Directly with a bundle license (EcoStruxure Control Expert XL with M580 Safety).
                                  (see page 1/24)
                                  The package comprises an EcoStruxure Control Expert V14 DVD in six languages
                                  (English, French, German, Italian, Spanish and Chinese).
7
                                                             Extra Large
                                                             Extra Large Safety
10
     Selection guide:
     page 1/2
      1/20
References (continued)   Software
                         EcoStruxure Control Expert software
                         Small
                         Group (3 stations)
                                                        Group (3 stations)
                                                                                      CEXUPNCZSTPMZZ
                                                                                                                        –
                                                                                                                        –
                                                                                                                            3
                         (1) For compatibility of EcoStruxure control Expert software/automation platforms and
                              distributed I/O, refer to the selection guide on page 1/2.
                         (2) Renewals for EcoStruxure Control Expert new versions are possible. Please contact our
                              Customer Care Center for more information.
10
                                                                                                                 1/21
     References (continued)       Software
                                  EcoStruxure Control Expert software
                                  Large
2
                                  Description                         License type             Reference                Weight
                                                                                                                         kg/lb
                                  EcoStruxure Control Expert Single (1 station)                CEXSPUCZLSPMZZ                  –
                                  Large software licenses
                                                             Group (3 stations)                CEXSPUCZLGPMZZ                  –
4
                                  Expert Small
                                  Type of upgrade                                              Reference                Weight
                                  The number of stations is unchanged                                                    kg/lb
                                  Small to Large Single (1 station)                            CEXUPGCZLSPMZZ                  –
10
      1/22
References (continued)   Software
                         EcoStruxure Control Expert software
                         Extra Large
EcoStruxure Control Expert Extra Large version 14 software licenses (1) (2)
                                                                                                                                   2
                         Description                       License type                   Reference                 Weight
                                                                                                                     kg/lb
                         EcoStruxure Control Expert Single (1 station)                    CEXSPUCZXSPMZZ                       –
                         Extra Large software licenses
                                                       Group (3 stations)                 CEXSPUCZXGPMZZ                       –
10
                                                                                                                      1/23
     References (continued)       Software
                                  EcoStruxure Control Expert software
                                  Extra Large Safety
                                  M580 Safety Add-ons
4                                 To manage all Modicon M580 Safety CPU models, the following licenses can be
                                  used:
                                  b	 CEXSPUCZXpPMZZ (EcoStruxure Control Expert Large) with
                                  CEXADSCZZpPMZZ (M580 Safety Add-On for L or XL single)
                                  b	 CEXSPSCZXpPMZZ (EcoStruxure Control Expert Large Safety)
EcoStruxure Control Expert Extra Large with M580 Safety software licenses (1)(2)
      1/24
References (continued)   Software
                         EcoStruxure Control Expert software
                         Small/Large/Extra Large/Extra Large Safety
                                                                                                                              3
                                                                        (mini-DIN/    8.20        (2)              0.331
                                                                        RJ45
TSXPCX1031                                                              cordset)
                                       Modbus port                      RS 232D       3.7/        990NAA26320      0.300/
                                       15-way SUB-D Quantum             (9-way        12.1                         0.661
                                       140CPU31110                      SUB-D         15/         990NAA26350      0.180/
                                       140CPU43412A                     connector)    49.2                         0.397
                                       140CPU53414B
                                       USB port
                                       Premium TSX575p/6p
                                                                        USB port      3.3/
                                                                                      10.8
                                                                                                  UNYXCAUSB033            –
                                                                                                                              4
                                       Quantum 140CPU6p1
                                       Modbus port, RJ45 connector RJ 45              1/          110XCA28201             –
                                       Quantum 140CPU6p1           connector          3.28
                                                                                      3/          110XCA28202             –
TSXCUSB485                                                                            9.84
                                                                                      6/
                                                                                      19.7
                                                                                                  110XCA28203             –   5
                         PC terminal HE13 connector Modicon             RS 232D    2/             STBXCA4002       0.210/
                         connection STB I/O network interface           (3)        6.56                            0.463
                         cables      module (NIM)                       (9-way
                         (PC SUB-D                                      SUB-D
                         to                                             connector)
                         Modicon STB
                         I/O)
                                                                                                                              6
                         USB/SUB-D     HE13 connector Modicon           USB port      –           SR2CBL06         0.185/
                         adaptor       STB I/O network interface        (4)                                        0.408
                         (PC USB to    module (NIM) with
                         Modicon STB   STBXCA4002 cable (4)
                         I/O)
                                                                                                                              8
                                       Designed for permanent installation and can be
TCSWAAC13FB                            fitted on the inside or outside of electrical
                                       enclosures.
                                       bb Protocols supported: Modbus and Uni-Telway
                                       bb Powered via the product’s RS 485 serial port
                                       bb Max. range in direct line of sight: 20 m/65.6 ft
10
                                                                                                                   1/25
1
10
     2/0
Contents   2 - EcoStruxure Control Expert
           Companion software
10
                                                                                                                        2/1
     Presentation,                                   Software
     setup                                           Unity Pro software
                                                     Unity EFB Toolkit software
                                                     Presentation
                                                     Unity EFB Toolkit software helps to develop EFs and EFBs in “C” programming
1                                                    language. As an option with Unity Pro, it can be used to extend the standard Unity
                                                     Pro function blocks in order to increase functionality. This software comes with
                                                     Microsoft Visual Studio, which can be used to debug the function blocks developed
                                                     in the Unity Pro PLC simulator. Unity EFB Toolkit also includes a service for creating
     Unity EFB Toolkit                               and managing families of function blocks and integrating them in Unity Pro.
                                                     Setup
2                                                    Unity EFB Toolkit manages the whole process of developing Unity Pro function
                                                     blocks:
                                                     bb User-friendly graphical user interface with automatic file organization
                                                     bb Powerful tools for testing and debugging
                                                     bb Management of compatibilities and software versions of created functions
                                                     bb Generation of executable files for subsequent installation of functions on different
3
                                                     Unity Pro stations
4                                                    extending the standard Unity Pro libraries. Integration in Unity Pro can be executed
                                                     from Unity EFB Toolkit or via the tool for updating Unity Pro libraries, which allows
                                                     these families to be distributed without the use of any other software.
7                                                    display of the code/data and manipulation of the data, can be accessed without
                                                     restriction.
                                                     bb Support for managing Unity Pro versions, important during the function block
                                                     maintenance phase
                                                     Compatibility
                                                     Unity EFB Toolkit is compatible with Unity Pro Medium, Large and Extra Large. EFs
8                                                    and EFBs can be developed for Modicon Premium, Quantum, M340, M580 and
                                                     Unity Momentum platforms.
10
       2/2
References   Software
             Unity Pro software
             Unity EFB Toolkit software
             References
             Unity EFB Toolkit and its documentation are supplied in electronic format on
             DVD-ROM in English and are available for download at schneider-electric.com.         1
             EFB Toolkit package includes:
             bb Unity EFB Toolkit DVD
             bb GNU Compiler CD
             bb Microsoft Visual Studio DVD
10
                                                                                            2/3
     Presentation,                      Software
     setup                              Unity Pro software
                                        Unity DIF software
Presentation
1
                                        Unity DIF software helps to compare two Unity Pro application files and represents
                                        differences in a graphical format similar to Unity Pro graphics for consistency and
                                        better understanding. The differences are displayed graphically and textually based
                                        on the type of section chosen. Unity DIF improves productivity during the main life
     Unity DIF                          stages of a control system, mainly during development and debugging of
                                        applications and commissioning, operation and maintenance of the installation.
                                        Setup
2                                       Unity DIF compares two Unity Pro application files (XEF, ZEF, STU and STA) and
                                        detects anything ADDED, DELETED and MODIFIED. The user interface and
                                        graphical representation of differences are similar to Unity Pro for consistency and
                                        ease of understanding the differences.
4
                                        bb Derived Data Types
                                        bb Derived FB Types
                                        bb Variables and FB Instance
                                        bb Motion
                                        bb Communication
                                        bb Programs
                                        bb Animation Table
5
                                        bb Operator Screen
                                        bb DTM Catalog
     Selection of elements to compare   bb Project Settings
The result of the comparison can be printed or saved in .pdf and .txt file formats.
Windows® OS Compatibility
6                                       Unity DIF is compatible with Windows 7 (32-bit and 64-bit), Windows 10 (32-bit and
                                        64-bit) and Windows Server 2008 R2 (64-bit).
                                        Comparison (1)
                                        The base and compare files have to be selected by the user, and the results of the
                                        comparison will be displayed with respect to the base file as reference.
7
                                        Before initiating comparison, the user can select his preference of required section
                                        for comparison.
                                        Displaying results
                                        Upon comparison, the section summary will be loaded with the complete list of differences.
                                        The user can navigate through the project browser window or using the F7 and F8 keys.
                                        The differences will be highlighted in three different colors signifying Added, Deleted or
8                                       Modified types. Colors can be customized as per the user’s preference. The detailed report
                                        can be generated through Print or can be Saved for later reference.
                                        Unity DIF also supports command line processing and .txt report generation for interfacing
                                        with Partner software.
Displaying results (1) Comparison of STU and STA requires Unity Pro to be available.
10
       2/4
References   Software
             Unity Pro software
             Unity DIF software
             References
             Unity DIF software is free and downloadable from our website:
             www.schneider-electric.com.                                                          1
             Compatibility: Unity Pro V2.1 or later.
              Description           Language            Type            Reference        Weight
                                                                                          kg/lb
             Unity DIF software     English (software   Single          UNYDFFXZZSPA80        –
                                    and electronic
                                    documentation)
                                                        license
                                                        (1 station)
                                                                        (1)
                                                                                                  2
             (1) Available on our website www.schneider-electric.com.
10
                                                                                          2/5
     Presentation                 Software
                                  Unity Pro software
                                  Unity Loader software
                                  Presentation
                                  Unity Loader is companion software to Unity Pro and is used to perform maintenance
1                                 operations on automation applications. Its easy setup and the small size of its
                                  executable make it a vital tool for updating Unity Pro projects without needing to use
                                  Unity Pro. It can also be used for updating the embedded software on Modicon
                                  M340, M580, M580S or Momentum Unity PACs or on Modicon X80 I/O modules. It
     Unity Loader                 performs the following main functions:
                                  bb Transferring automation project components, such as the program and data, from
                                  the PC to the PAC or the PAC to the PC
2                                 bb Transferring files and user Web pages stored in the memory card of Modicon
                                  M340 PACs
                                  bb Transferring the firmware from the PC to Modicon M340, M580, M580S or
                                  Momentum Unity PACs or to Modicon X80 I/O modules
4
                                  PAC, Unity Loader displays the information associated with the data read in the PAC.
                                  This information is displayed on the PC for the selected files. The user decides which
                                  project elements will be transferred by a single command after validation of the
                                  required transfers.
                                  vv Modicon M340 PACs and BMXRMSpp8MFP memory card only: the files and user
                                  Web pages can be transferred from the memory card to the PC and vice versa.
     Unity Loader: Project tab    vv BMXNOE0110 with flash memory card only: Web pages stored in the flash
5
                                  memory can be transferred from the module to the PC and vice versa.
                                  bb The “Firmware” tab can be used to update the firmware in the Modicon M340,
                                  M580, M580S or Momentum Unity PACs or on Modicon X80 I/O modules. The
                                  screen displays the detailed content of the firmware versions existing in the module
                                  and on the PC. Firmware updating works in the same way as project transfers.
                                  bb The “Options” tabs is used to configure the working environment, especially the
                                  location of files on the PC and the selection of one of the six languages supported
                                  (English, French, German, Italian, Spanish and Chinese) for the user interface and
6                                 online help.
                                  bb The “About…” tab displays information about the software.
                                  Note: Regardless of which tab is selected, the connection status with the PAC is continuously
                                  displayed, together with commands for connection/disconnection and changing the PAC
                                  operating mode.
8
                                  Automation of Unity Loader commands
                                  Projects can be downloaded/uploaded between a PAC and a supervisory station
                                  equipped with Unity Loader software by means of a command file included in the
                                  supervisory application.
10
      2/6
Presentation (continued),   Software
references                  Unity Pro software
                            Unity Loader software
                                                                                                                          3
                            BMXNOE0100/0110           X80 module Ethernet
                                                      Modbus/TCP
                            BMXAMI/ART/AMO/AMM        X80 module Analog I/O
                            BMXEHC0200/0800           X80 module Counter
                            BMXMSP0200                X80 module Motion
                                                      control
                            BMEP58                    M580 CPUs
                                                                                                                          4
                            10XX/20XX/30XX/40XX
                            BMENOC03p1                M580 communication
                                                      module
                            171CBU78090               Momentum Unity CPU
                                                      with integrated port
                            171CBU98090/              Momentum Unity CPU
                            171CBU98091               with integrated port
                            References                                                                                    6
                            Unity Loader can be downloaded free of charge from our website
                            www.schneider-electric.com, download section.
                            Compatibility
                            Unity Loader is independent of Unity Pro and compatible with Modicon M340, M580
                            or Momentum Unity PACs, Unity Pro Quantum PACs via Modbus and Unity Pro
                            Premium PAC via Unitelway. The program files and PAC data files are compatible
                                                                                                                          7
                            between Unity Pro and Unity Loader.
10
                                                                                                                   2/7
     Presentation               Software
                                Unity Pro software
                                Specific libraries
                                Presentation
                                The CONT_CTL process control function block library supplied with Unity Pro
1                               software can be supplemented with optional specialized libraries so as to meet
                                specific needs such as:
                                bb Predictive control
                                bb Fuzzy logic controller
     Unity specific Libraries   bb HVAC
                                bb Mass flow calculation
4
                                TeSys Library
                                This library provides function blocks for TeSys T and TeSys U starter-controllers for
                                M340 and Premium platforms.
                                It includes function blocks and a help function for Unity Pro.
7                               This library offers functional blocks that are derived from Devices and Process
                                Library but only has Unity Pro components (DFBs).
                                The Devices and Process Library supports several Schneider Electric devices
                                including TeSys T and TeSys U starters-controllers, Modicon STB distributed inputs/
                                outputs, power meters, Altivar variable speed drives, Icla and Lexium integrated
                                drives, SEPAM digital protection relays, various fieldbus communications and other
                                standard objects for motors.
8                               There are approximately 100 objects in the library.
10
      2/8
References                 Software
                           Unity Pro software
                           Specific libraries
                                                                                                                    3
                           Heating Ventilation & Air                                   UNYLHVZAUWB10            –
                           Conditioning Library
10
                                                                                                          2/9
1
10
     3/0
Contents   3 - EcoStruxure OPC UA
           Server Expert
10
                                                                                                                           3/1
     Presentation                           3
                                                 Software                                                                                3
                                                 Presentation
                                                 EcoStruxure OPC UA Server Expert is a state of the art Schneider Electric
1                                                communications software platform. It seamlessly links our process automation edge
                                                 controllers and connected field devices to your information systems and the Industrial
                                                 Internet of Things (IIoT). The connections are established via the OPC Foundation’s
                                                 Open Platform Communications conforming to the Unified Architecture (OPC UA)
                                                 service-oriented architecture standard.
     EcoStruxure OPC UA Server Expert
                                                 The OPC UA standard defines a modern, open communications architecture for
2                                                industrial communications that enhances cybersecurity and that is scalable from
                                                 resource constrained sensors through to cloud enterprise systems. OPC UA
                                                 extends the traditional industrial communications model with a full Service
                                                 Orientated Architecture (SOA) to publish and manage device metadata, and
                                                 context, thus helping to eliminate repetition, to simplify system configuration and to
                                                 reduce maintenance overhead.
3                                                Building on the field-proven device integration layer of OPC Factory Server (OFS),
                                                 EcoStruxure OPC UA Server Expert updates legacy ‘OPC Classic’ communications
                                                 provided by OFS with scalable OPC UA connectivity. It helps to maintain more
                                                 robust and secure integration with current and legacy Schneider Electric third-party
                                                 field devices.
                                                 With the V2.0 release, OPC UA Server Expert provides the following features:
4                                                bb Compliance with OPC UA V1.03 ‘Standard Server’ profile
                                                 bb IP-routable, bandwidth-efficient connectivity that helps to ensure communications
                                                 security
                                                 bb Compatibility with modern communications infrastructure
                                                 bb Certificate-based authentication and encryption helping to ensure more robust
                                                 end-to-end cybersecurity
                                                 bb Metadata model support to define and communicate data structure, meaning, and
5                                                context
                                                 bb Highly-available redundant architectures with auto change over
                                                 bb Flexible ‘many-to-many’ device to OPC UA client connectivity
                                                 bb Online real-time update capabilities
                                                 bb Support for Modicon located and unlocated symbols
                                                 bb Assistance in maintaining safe, read-only access to Modicon M580 Safety ePAC
                                                 symbols
10
                                                 automatically changes over from the primary to the standby communication path
                                                 without interrupting upstream OPC UA communications.
       3/2
Architectures                                         0
                                                           Software                                                                            3
Use cases
The inclusion of OPC UA technology within OPC UA Server Expert enables a modern, open approach to industrial device data connectivity,
benefiting two different types of user requirements:                                                                                                1
bb Operational users who wish to directly monitor and control field equipment via supervisory control (SCADA) or human/machine interface
applications to manage the real-time operation of industrial processes.
These users can take advantage of the high performance and the support delivered by OPC UA Server Expert in providing a more robust and
secure communications platform.
bb Analysts or asset owners wishing to consolidate and analyze device and process data to drive performance insight and directed
improvement through advanced business intelligence and machine learning techniques.
These users can take advantage of the interoperable open standards, flexibility, metamodel capability and simplified SOA integration provided
                                                                                                                                                    2
by OPC UA Server Expert.
Supported architectures
EcoStruxure OPC UA Server Expert supports:
bb Local or remote access via OPC UA
bb Standalone or redundant server operation                                                                                                         3
 Local access
The client application and the EcoStruxure OPC UA Server Expert are on the same PC.
                                                 Local client
                                                 application
                                                                               EcoStruxure                                                          4
                                                                               OPC UA
                                                 program                       Server Expert
        Modbus network                                                                                                                              5
 M580                                                                             M340
                                                                                                                                                    7
The client application and the EcoStruxure OPC UA Server Expert are on remote stations.
Communication between the client station and the EcoStruxure OPC UA Server Expert is conducted via the OPC UA protocol.
Ethernet network
      Remote client
                                    OPC UA                      Local client
                                                                application
                                                                                          EcoStruxure                                               8
      application                                                                         OPC UA
      program                                                   program                   Server Expert
                                Modbus network
                                                                                                                                                    9
            M580                                                                  M340
10
                                                                                                                                         3/3
     Setup                                                      Software                                                                           3
Setup
1 Ethernet Modbus/TCP
     2                                              1           EcoStruxure                                            4
                                                                OPC UA
                            EcoStruxure
                                                                Server Expert
2
                            OPC UA
                                                                server
                            client
                                                                                                                             EcoStruxure
                                                                                  Database        Symbols.xvm
                                                                                                                             Control Expert
                                                                                                  (EcoStruxure
                                                                                                                             project station
                                                                                                  Control Expert)
3 3 3
M580 M340
4 Modbus network
     The EcoStruxure OPC UA Server Expert server 1 is at the center of the data exchanges. It makes variables exchanged between the EcoStruxure
     OPC UA client 2 and the PAC 3 consistent in one of the ways described below using a symbol (or variables) database:
5
     bb The variables database is the PAC itself.
     In this case, EcoStruxure Control Expert is not needed. This does not apply to the Momentum PAC. If an inconsistency is detected (following
     online modification of the PAC program for example), the EcoStruxure OPC UA Server Expert server station resynchronizes itself automatically
     as a background task, without breaking communication between the PAC and the OPC UA client.
bb The accessible variables are eventually provided by an export file (XVM format) generated by ExoStruxure Control Expert.
In this case, EcoStruxure Control Expert is not required to be installed on the EcoStruxure OPC UA Server Expert server station.
10
         3/4
Functions,                                        Software                                                                                             3
references                                   3
                                                  EcoStruxure OPC UA Server Expert
                                                  System requirements
                                                  EcoStruxure OPC UA Server Expert V2.0 is compliant with following platforms:
                                                  bb Microsoft Windows® 7
                                                  bb Microsoft Windows 10
                                                                                                                                                            1
                                                  bb Microsoft Windows Server® 2012 R2 (1)
                                                  bb Microsoft Windows Server 2016 (1)
EcoStruxure OPC UA Server Expert                  32-bit and 64-bit platforms are supported, with a minimum of 4GB RAM required.
                                                  Multicore/multiprocessor architectures are highly recommended for optimal runtime
                                                  performance.                                                                                              2
                                                  Unity Pro V13, EcoStruxure Control Expert V14 or higher is recommended.
                                                  References
                                                  The EcoStruxure OPC UA Server Expert V2.0 offer comprises:
                                                  bb OPC UA server software
                                                  bb OPC UA server simulator                                                                                3
                                                  bb OPC UA server configuration software
                                                  bb An example OPC UA client
                                                  bb Setup documentation
EcoStruxure OPC UA Server Expert interfaces with variable export files generated
                                                                                                                                                            4
                                                  by EcoStruxure Control Expert software. It also provides a direct dynamic link to
                                                  EcoStruxure Control Expert applications.
10
                                                                                                                                                  3/5
1
10
     4/0
Contents   4 - OPC data server software:
           OFS (OPC Factory Server),
           Time stamping system
10
                                                                                                                            4/1
     Presentation        3
                              Software                                                                                 3
                               Presentation
                              Based on the OLE for Process Control (OPC) standard, Schneider Electric's OPC
1                             Factory Server (OFS) software allows “client” software applications, such as
                              supervisors/SCADA and customized interfaces, to access the data of Schneider
                              Electric automation system and electrical distribution devices connected to networks
     OPC Factory Server       or fieldbuses in real time.
                              It also allows communication with third-party devices supporting Modbus and
                              Modbus/TCP protocols.
2                             OFS enables simpler, more open and transparent communication between your
                              software applications and your devices. These are just some of the advantages that
                              result in a complete interoperability solution that is central to your process.
                              There are two versions of the OFS V3.6 offer supporting the OPC DA protocol:
                              bb OFS Small: Data server for 1,000 items (1).
4                             bb OFS Large: Data server with an unlimited number of items (1).
                               Openness
8                             The development of specialized interfaces is simpler with OFS V3.6 software, which
                              is aimed at two types of user in particular:
(1) “item”: variable, structure, table etc. in the Unity Pro application.
10
     4/2
Architectures                             0
                                               Software                                                                                         3
                                               Supported architectures
                                               The OFS server allows four access modes:
                                               bb A purely local mode
                                               bb Remote access from an OPC DA client
                                                                                                                                                     1
                                               bb Remote access from an OPC.NET client
                                               Local access
                                               The client application and the OFS server are on the same PC.
                                                                                      OFS station                                                    2
                                                                                       Local client
                                                                                       applic. prog                               Symbol data
                                                                                                                                  (Unity Pro,
                                                                                                                                  Concept
OPC Factory Server: Home page                                                                                                     or PL7)
                                                                                                                                                     3
                                                   Modbus network
                                                       Remote client
                                                                                 OFS station
                                                                                       Local client
                                                                                                                                                     6
                                                        application                    applic. prog                               Symbol data
                                                         program                                                                  (Unity Pro ,
                                                                                                                                  Concept
                                                                                                                                  or PL7)
                                                                                                                                                     8
                                                                                                      Premium              M340
                                                                         M580
Quantum
10
                                                                                                                                          4/3
     Architectures (continued)    0
                                       Software                                                                              3
Intranet
                                       The .NET Microsoft compatibility of the OFS server has been developed to allow an
                                       OPC .NET client to access OFS server items on an Intranet network via the OPC
                                       .NET API interface.
4                                      This interface provides interoperability between existing OPC applications and
                                       applications developed in the standard .NET environment.
10
       4/4
Setup                                                     3
                                                                   Software                                                                                 3
Setup
       Ethernet Modbus/TCP                                                                                                                                       1
                                                               1
                                                    OFS server
                                                        (V3.0)                                                                                 4
                                                                                  Database                                                     Unity Pro
                                                                                                                                               project
                                                                                                                                               station
                                                                                                                                                                 2
                                                                                   Symbols.xvm (Unity Pro)
                                                                                   Symbols.prj (Concept)
                2 OPC client                                                       Symbols.scy (PL7)
                                3 Quantum
                                                                                                                                                                 3
                                                                                                                3 Premium
       Ethernet Modbus/TCP
                                                3 M580                          3 M340                                                                           4
                                                                   The OFS server 1 is at the center of the data exchanges. It makes variables
                                                                   exchanged between the OPC client 2 and the PAC 3 consistent in one of three ways,
                                                                   using a symbol (or variables) database:
                                                                   bb The variables database is either the Unity Pro project 4, or the Concept project.
                                                                                                                                                                 5
                                                                   In both these cases, Unity Pro or Concept needs to be installed on the OFS server
                                                                   station.
                                                                   bb Or the variables database is an export file (SCY for PL7, XVM for Unity Pro). PL7
                                                                   and Unity Pro are not required in either of these cases.
                                                                   bb Or the variables database is the PAC itself. In this case neither Unity Pro nor an         6
                                                                   export file is needed. This does not apply to Momentum and TSX Micro PACs. If an
                                                                   inconsistency is detected (following online modification of the PAC program for
                                                                   example), OFS resynchronizes itself automatically as a background task, without
                                                                   breaking communication between the PAC and the OPC client.
                                                                   For this function the following minimum versions are required:
                                                                   vv OFS V3.35
                                                                   vv Unity Pro V6.0                                                                             7
                                                                   vv Modicon M340 V2.3, M580 V1.0, Premium V2.9 and Quantum V3.0 PACs
10
                                                                                                                                                       4/5
     Functions                       3
                                          Software                                                                                   3
                                          Functions
                                          Development of client applications
1                                         OFS software has 4 types of interface:
2
                                          bb OLE Custom interface (OPC DA)
                                          Used primarily by suppliers of automated control system or industrial IT products,
                                          this interface enables the development of applications in C++ in order to access the
                                          OFS software OPC server. It is aimed at software development experts in particular,
                                          so that they can integrate the client application into their standard products. It is the
                                          interface with the highest performance, in terms of access time to data stored in the
                                          OPC server. It requires extensive knowledge of C++ programming to set up.
10
       4/6
References                           3
                                          Software                                                                                                 3
                                           References
                                          OFS V3.6 software for PC compatible stations (minimum configuration: Pentium
                                          566 MHz processor, 128 MB of RAM) running Windows® 7 (32-bit or 64-bit) or
                                          Windows 8 (32-bit or 64-bit).
                                                                                                                                                        1
OPC Factory Server                        The OFS V3.6 offer comprises:
                                          bb OPC server software
                                          bb OPC server simulator (for debugging the application when no PACs are present)
                                          bb OFS server configuration software
                                          bb An example of OPC client for setting up applications
                                          bb The setup documentation on DVD-ROM
                                                                                                                                                        2
                                          bb A reference document on “time stamping system” solutions
                                          bb A tool to help with sizing and configuring “time stamping system” solutions
                                                                                                                                                        7
                                          items (1)               200 stations                                   TLXCDLFOFS36                       –
                                          bb Protocols supported:
                                          OPC DA, OPC XML-DA
                                          and OPC UA
                                           OPC Factory Server V3.6 upgrades
                                           Description                                                           Reference               Weight
                                                                                                                                          kg/lb
                                                                                                                                                        8
                                          Update for OPC Factory                                                 TLXCDUPDSOFS                       –
                                          Server V3.6 Small
(1) “item”: variable, structure, table etc. in the Unity Pro application.
10
                                                                                                                                              4/7
     Presentation                                                       Software                                                                                 3
                                                                        Presentation
                                                                        The time stamping system is a complete solution providing a SCADA with a
1                                                                       sequence of events that are time-stamped at source, enabling the user to analyze
                                                                        the source of any abnormal behavior in an automated system.
                                                                        The SOE (sequence of events) is displayed in the alarm log or in the list of events for
                                                                        a client such as a SCADA.
2                                                                       Each event in the SOE is a change of value (transition) of a discrete I/O detected by
                                                                        a time stamping module.
                                                                        Advantages
                                                                        Using the time stamping system has the following advantages:
                                                                        bb No PAC programming
                                                                        bb Direct communication between the time stamping modules and the client. If the
3                                                                       time stamping modules are in an Ethernet I/O drop, the bandwidth of the PAC
                                                                        communication is not used
                                                                        bb Consistency of the I/O values between the process (time stamping modules) and
                                                                        the client
                                                                        bb Consistency is maintained irrespective of the operating mode
                                                                        bb No loss of events under normal operating conditions
                                                                        bb Management of Hot Standby configurations on the PAC and/or SCADA
4                                                                       redundancy
5                                           M580
                                                                        To avoid losing any events, all events are stored and kept in a buffer located in the
                                                                        product until OFS takes them.
                                                                        Synchronization of the CRA module uses the NTP protocol.
                                                                         BMXERT1604T module
                                                                        This module has 16 discrete inputs which carry out the time stamping on source
                                                                        outputs with a resolution of 1 ms.
6                                                                       To avoid losing any events, the events are stored and kept in a buffer located in the
                                                                        product until OFS takes them.
                                          Routing function via          This module can be placed either in an RIO drop, or in a local rack equipped with a
             Ethernet                    Quantum NOC control
                                         head 140NOC78100
                                                                        BM●CRA31210 module.
                                           or external router          The CRA module is synchronized via the DCF 77 or IRIG-B standards.
OFS V3.6
7                                                                       OFS V3.6 is used to access events stored in the various buffers in the architecture
                                                                        and to notify the SCADA of them via the standard OPC DA protocol.
                                 BMX-CRA1          BMX-ERT1
                                 event             event
                                  emory
                                 m                 memory
                 Modicon X80
                                                                        Time stamped variables can be provided by the BMXERT1604T, discrete modules
                 drops                                                  plugged into X80 drops, or even by the CPU since Unity V10.
8                                BMX-CRA2
                                 event
                                 memory
                                                   BMX-ERT
                                                   event
                                                   memory
                                                                         Vijeo Citect V7.3
                                                                        Vijeo Citect V7.3 receives events transmitted by OFS and displays them in the SOE
                 Modicon X80
                 drops                                                  or in the list of alarms.
                                                                        Wonderware WSP
                                 BMX-CRA3          BMX-ERT
                                 event             event                A specific OFS V3.6 version dedicated to the Wonderware platform is available on
       4/8
Performance                      Software                                                                                         3
                                 Performance
                                 Performance                                    Event source       Value
                                                                                                                                       2
                                                                                BM●CRA31210        2,048 events (1)
                                 Maximum number of I/O and memory               BMXERT1604T        16 discrete inputs on module
                                 available
                                                                                                   512 events in internal buffer
                                                                                BM●CRA31210        256 discrete I/O configured
                                                                                                   4,000 events in internal
                                                                                                   buffer
                                                                                                                                       3
                                 Maximum number of source modules in an BM●CRA31210                1 per drop
                                 Ethernet remote drop                   BMXERTpppp                 9 per drop
                                 Maximum number of event sources                BMXERTpppp         500 sources per second (1)
                                 controlled
                                 (1) This maximum value is not an absolute value. It depends on the overall system dynamics
                                      (total number of scanned items and number of events generated by the system).
10
                                                                                                                           4/9
1
10
     5/0
Contents   5 - Product reference index
10
                                                                                                                5/1
     Index                                           Product reference index
     #                       TLXCDLUOFS36      4/7
     110XCA28201      1/25   TLXCDSTOFS36      4/7
1    110XCA28202
     110XCA28203
                      1/25
                      1/25
                             TLXCDSUOFS36
                             TLXCDUPDLOFS
                                               4/7
                                               4/7
     990NAA26320      1/25   TLXCDUPDSOFS      4/7
     990NAA26350      1/25   TSXCRJMD25       1/25
                             TSXCUSB485       1/25
     B                       TSXPCX1031       1/25
2    BMXXCAUSBH018
     BMXXCAUSBH045
                      1/25
                      1/25   U
                             UNYDFFXZZSPA80    2/5
     C                       UNYLAGZAUWB20     2/9
     CEXADSCZZEPMZZ   1/24   UNYLFZZAUWB12     2/9
     CEXADSCZZGPMZZ   1/24   UNYLHVZAUWB10     2/9
3    CEXADSCZZSPMZZ
     CEXADSCZZTPMZZ
                      1/24
                      1/24
                             UNYLPCZAUWB
                             UNYLTSZAUWB10
                                               2/9
                                               2/9
     CEXPACKAGEV14    1/20   UNYSPUZFUCD80     2/3
     CEXSPSCZXEPMZZ   1/24   UNYXCAUSB033     1/25
     CEXSPSCZXGPMZZ   1/24
     CEXSPSCZXSPMZZ   1/24
4    CEXSPSCZXTPMZZ
     CEXSPSEZXEPMZZ
                      1/24
                      1/24
     CEXSPUCZLGPMZZ   1/22
     CEXSPUCZLSPMZZ   1/22
     CEXSPUCZLTPMZZ   1/22
     CEXSPUCZSGPMZZ   1/21
5    CEXSPUCZSSPMZZ
     CEXSPUCZSTPMZZ
                      1/21
                      1/21
     CEXSPUCZXEPMZZ   1/23
     CEXSPUCZXGPMZZ   1/23
     CEXSPUCZXGPTZZ   1/23
     CEXSPUCZXSPMZZ   1/23
6    CEXSPUCZXTPMZZ
     CEXSPUCZXTPTZZ
                      1/23
                      1/23
     CEXUPGCZLGPMZZ   1/22
     CEXUPGCZLSPMZZ   1/22
     CEXUPGCZLTPMZZ   1/22
     CEXUPGCZXGPMZZ   1/23
7    CEXUPGCZXSPMZZ
     CEXUPGCZXTPMZZ
                      1/23
                      1/23
     CEXUPNCZLGPMZZ   1/22
     CEXUPNCZLTPMZZ   1/22
     CEXUPNCZSGPMZZ   1/21
     CEXUPNCZSTPMZZ   1/21
8    CEXUPNCZXGPMZZ
     CEXUPNCZXTPMZZ
                      1/23
                      1/23
     O
     OFSUASCZZEPMZZ    3/5
     OFSUASCZZSPMZZ    3/5
9 OFSUASCZZTPMZZ 3/5
     S
     SR2CBL06         1/25
     STBXCA4002       1/25
10   T
     TCSWAAC13FB      1/25
     TLXCDLFOFS36      4/7
     TLXCDLTOFS36      4/7
      5/2
                          Learn more about our products at
                          www.schneider-electric.com
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the
products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability
of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk
analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric
nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
MKTED2140504EN
September 2019 - V6.0