LD-30FTA: Tension Controller Model Instruction Manual
LD-30FTA: Tension Controller Model Instruction Manual
TENSION CONTROLLER
MODEL   LD-30FTA
INSTRUCTION MANUAL
                                                                                                        LD-30FT
                                                                              TENSION CONTROLLER
                                                                                                           A
         設定登録   1   2    3    4   5   6   7   8                              SPA
         MENU
                                                                                                               φ
                                                                                                               %
                                                材料厚
                                                                   設定切替
                                              THICKNESS
                         μm
                                                                    PALAM
                          φ
                                                   巻径                                 出力/OUTPUT
                          %
                         SEC                      REEL DIA
                             巻径初期化
                             D.RESET                         手動/MANUAL                  自動/AUTO
                                                                              張力設定/TENSION SET             F
                                                                                             5
                    ON
                    OFF                            ー                     +
                                                                                         0         10
                                     Cautions on Safety
                                   (Make sure to read this page before using the unit .)
 • The unit is manufactured under the severe quality control .          CAUTION: When the unit is handled incorrectly , a
   When a severe accident or loss is expected in the                                   dangerous situation may occur and the
   equipment used due to failure of the unit , provide a backup                        possibility of medium or slight injury is
   function or the fail -safe function in the system .                                 expected or property damage exclusively
                                                                                       is expected.
In this manual , cautions of safety are classified into "DANGER"
and "CAUTION".                                                     Even an item is classified as " CAUTION", its contents are
                                                                   important and it may lead to a serious result depending on the
                                                                   situation. Make sure to observe every item .
                 Turn off all the phases of the external power                       Design the installation plan using the wire
    DANGER supply before starting installation and wiring .             DANGER size suitable to the current capacity .
      Otherwise, electrical shock or damage in the unit may              Use the wire size suitable to the current capacity to
      occur. Make sure to turn off all the phases of the                 supply the power to the load . If a wire having smaller
      external power supply before starting installation and             current capacity is used,the insulation sheath will be
      wiring.                                                            melted and insulation will become defective . In this
                                                                         situation, electrical shock or a short-circuit may occur,
                                                                         and fire may occur .
                    Never drop cutting chips and wire chips            CAUTION Confirm the ambient enviroments .
     DANGER while screw holes are tapped and wiring
                    work is performed.                                Never install the unit with an enviroment where dusts , soot,
      Damage , fume, fire, malfunction or others may be               conductive dusts or corrosive gas is present or a place
      caused in the unit .                                            exposed to high temperature , condensation or wind and
                                                                      rain. Otherwise, the unit may be damaged , malfunction or
                                                                      be deteriorated .
     DANGER Never modify nor disassemble the unit                                    Do not use any unused terminals for any
                                                                        CAUTION external lines.
      Never modify nor disassemble the unit . Otherwise, the
      unit may become defective or an accident such as fire ,         Correctly connect the AC power cable to the specified
      damage , etc. may occur.                                        terminal, and do not use any unused terminals for any
                                                                      external lines. Improper connection may seriously
                                                                      damage the product .
CAUTION              • We shall not be responsible for any damage caused by repair , disassembly, modification, etc. performed
                       by a third party other than MITSUBISHI or a company specified by MITSUBISHI .
                     • The cautions on safety and the specifications described in the instruction manual are subject to change
                       without notice .
  Table of Contents
1. Outline
  1.1   Functions and features - - - - - - - - - - - - - - - - - - - - - - - - - - - -          2
  1.2   Panel Configuration - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -         4
  1.3   DIP switch functions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -        4
  1.4   Operating / Setting Procedure - - - - - - - - - - - - - - - - - - - - - - -             5
3. Specifications
  3.1   External wiring diagram and terminal arrangement - - - - - - - -                        8
  3.2   Input/output specifications - - - - - - - - - - - - - - - - - - - - - - - - - -          9
  3.3   Environmental specifications - - - - - - - - - - - - - - - - - - - - - - - -            9
  3.4   I/O operation(Example of unwinding control) - - - - - - - - - - - - -                   10
4. Set Parameters
  4.1 Set items and Types - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11
  4.2 Adjustment Procedure- - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12
  4.3 Details of set items - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13
6. Setting Examples
  6.1 Application example : Proximity switch - - - - - - - - - - - - - - - - - 17
  6.2 Application example : Ultrasonic sensor - - - - - - - - - - - - - - - - 18
                                                                        1
 1. Outline
Unwinding bobbin
                                                           2
The ultrasonic sensor and the touch lever can be used.
  The use of the ultrasonic sensor and the touch lever becomes possible by installing analog input board
  (LD-30FTA-1AD) of the option.
  As a result, the operator becomes possible the automatic operative method only because of the tension
  setting according to an analog volume.
Converting machinery
  ・Print machine and screen printing machine
  ・Slitting . cutting and laminating machine
  ・Paste putting machine and coating machine
  ・Washing machine and drying machine
  ・Cutting machine and punching machine
  ・Reel machine and inspection machine
  ・Wrapping machine and filling machine
  ・Surface processing machine
  ・Stranded wire machine
  ・Textile machine, needlework, and dye machine
  ・Rolling mill and wire drawing machine
Winding bobbin
Feed roller
                                                                                               Servo motor
                                                                                                               S
                                                                                                               M
       Following parameters can be also set .
                                                                                Tension setting
         •Minimum/maximum winding diameter
         •Taper ratio (advanced function mode)
         •Five items related to inertia compensation                   Optional card                          Servo
                         (advanced function mode)                                                            amplifier
                                                                        Type LD-30FTA
         •Mechanical loss (advanced function mode)                     Tension control unit
         •Weak excitation (advanced function mode)
         •Winding shaft pulse (advanced function mode)
         •Compensation for non-linear torque
          characteristic (advanced function mode)
                                                                3
                                                                                                                                                        Panel Configuration
1.2 Panel Configuration
                           (7)Materal                      (8)Parameter setting                                              (9)Menu selector keys                   (11)Output display and
                              thickness set key               selector key                                                      and indicator lamp                       diameter monitor display
                           (6)Initial                                                                                         (10)Pulse monitor
                              diameter set key                                                                                    indicator lamp
   (5)Material thickness
      and parameter item
      display                                                                                                           TENSION CONTROLLER      LD-30FTA
                                           設定登録   1    2    3     4   5   6   7   8                                    SPA
   (4)Reel diameter and                    MENU
                                                                                                                                                    φ                 (12)Display selector key
      parameter data display                                                       材料厚
                                                                                                          設定切替
                                                                                                                                                        %
                                                                                  THICKNESS
                                                            μm
                                                                                                             PALAM
                                                             φ
   (3)Reel diameter                                           %
                                                            SEC
                                                                                      巻径
                                                                                      REEL DIA
                                                                                                                                 出力/OUTPUT
      reset key
                                                                巻径初期化
                                                                D.RESET                          手動/MANUAL
                                                                                                                                                                      (13)Output ON/ OFF key
                                                                                                                                 自動/AUTO
                                                                                                                         張力設定/TENSION SET           F
   (2)Keyin inhibit key and                           ON
                                                                                                                                      5
      indicator lamp
                                                      OFF
                                                                                                                                  0        10
                                                                                                                                                                      (14)Automatic control mode
                                                                                                                                                                          keys and indicator lamp
         1            2           3           4                           5                          6                   7                      8
     Unwinding     ×1          Unused      Unused                Always                          Normal               Easy                Operation
ON
                                                                                                                                                               OFF
                                                                                                                     Advanced
     Winding      ×0.1          Used        Used                                            Initialization            function            Tunning
                                                                                                                                                            All the bits of the DIP switch are
                                                                                                                                                            set to ON when the tension
                                                                                                                                                            control unit is shipped from the
                                                                                                                                                            works.
                                                                                                      4
1.4 Operating / Setting Procedure
                   Switch manipulation
   Normal
  operation         ・When the power switch 1 is set to ON, the power indicator lamp is lit and the version of the
                     tension control unit flickers on the monitor display 11 for approximately 2 seconds.
 Refer to P.19      ・Every time the output ON/OFF key 13 is pressed, the control output is toggled between ON
                     and OFF. While the output is set to ON, the output indicator lamp is lit.
                     When the DIP switch is set so that the remote output can be used, the output can be also set
                     to ON or OFF by that input.
                          (Note) Use the Output ON/OFF key 13 or [REM] input without using the
                                 Power switch 1 when the output is turned on and off.
                                      ・Allowable power switch life cycles : 20,000 times
2.1 Installation
       DANGER                                                                • Never drop cutting chips and wire chips while screw holes are tapped and wiring
                                                                               work is performed. Otherwise, damage, fume, fire, malfunction or others may be
                                                                               caused in the unit.
                                                                             • Make sure to turn off all the phases of the power supplies outside before starting
                                                                               installation and wiring.
                                                                             • Make sure to attach the terminal block cover offered as an accessory to the unit
                                                                               to prevent electrical shock before supplying the power after the wiring work.
       CAUTION                                                               • Never install the unit in a place with dusts, soot, conductive dusts or corrosive gas
                                                                               or a place exposed to high temperature, condensation, wind or rain. Never install
                                                                               the unit directly in a place in which vibration or impact is applied.
                                                                               Otherwise, damage, malfunction or deterioration may be caused.
The tension controller can be installed on the floor, wall or panel surface.
                                                                                                                φ
                                                                                                                %
                                                 材料厚
                                                                    設定切替
                                               THICKNESS
                          μm
                                                                     PALAM
                           φ
                                                    巻径                                  出力/OUTPUT
                           %
                                                   REEL DIA
                                                                                                                             168
                              巻径初期化
                              D.RESET                         手動/MANUAL                  自動/AUTO
                                                                                張力設定/TENSION SET            F
                                                                                               5
                     ON
OFF
0 10
                                                                                                                                                         22 or less
                                                                                                                                                                                    172.5
                                256
                      Installed on floor surface                                                                                                                        Installed on wall surface
                                                                                                                                                                                               Perform pressure
                                                                                                                                                                                               welding from the rear
                                                                                                                                                                                               face with fixing
                                                                                                                                                                                               screws.
     Screw hole dimensions when installed on floor or wall                                                                                                                 Mounting screw
                                                                                                                                                                           4-M4×12
                          Screw 4ーM4
                                                                                                                    80±0.5
                                                                               +3
                                                                    244        ー0.5
232±0.5
                                                                             • When installing the tension control unit on the floor surface or wall surface, use the
       CAUTION                                                                 screws offered as accessories to fix the main body and the mounting legs.
                                                                               Screws whose length is not less than 10 mm cannot be used because such screws
                                                                               may be in contact inside the main body.
                                                                             • Perform ClassD grounding ( 100Ω or less )for the casing on sheet metal using a
                                                                               screw hole on the side on which the main body mounting plate is not fixed.
                                                                                                                                                 6
 When the front door is open, the terminal block for exter-
 nal connection can be seen inside the box.
 Pull out the cables to the outside from the cable outlet
 slots provided in the lower portion of the box.
                                                                      Flat cable
                                                                                                            Plate
                                                                         DIP switch
                                                                                                             Terminal cover
2.2 Mounting the type LD-30FTA-1AD                                                                           Optional card
    optional card
       (When you used the option function)                          Lead wire
                                                                       Plate stud
                                                                    Terminal block
 Make sure to shut down all the phases of the external
 power supply.Then, open the front door. Disconnect the             Cable outlet slot
 flat cable . Remove the plate inside the box (by holding
                                                                                                         Connector
 the tip of the studs at the four corners and pulling out the
 plate). Insert an optional card into the connector. Attach
 the plate again.
2.3 Wiring
 • Perform the wiring refering to the wiring diagram and terminal arrangement
   as shown in Section 3.1.
                                                                                          7 .8 or less
 • Use crimp-style terminals whose dimensions are as shown in the figure on
   the right.
 • The terminal tightening torque shall be 0.5 to 0.8 N•m. Tighten the terminals                   M3.5
                                                                                          7 .8 or less
   securely so that malfunction will not be caused.
 • Perform Class D grounding ( 100Ω or less ) to the analog I/O cables and the
   winding shaft pulse input cable with shielded cables on the signal receive
   side.
 • Never let the I/O cables pass through a duct together with other power cables. Never bind the I/O cables
   together with other power cables.
 • Generally, the allowable wiring length shall be 10 m or less to assure safety against noise.
      DANGER             • Make sure to shut down all the phases of the external power supply. Then, start the
                            installation/wiring work.
                         • If all the phases are not shut down, you may get electric shock or the tension control
                            unit may be damaged.
                            Perform Class D grounding ( 100Ω or less ) to the ground terminal and the sheet met-
                            al of the casing of the tension control unit with electric wires of 2mm2 or more. If Class
                            D grounding ( 100Ω or less ) is not performed, electric shock may be caused.
                         • When supplying the power to a load, use an electric wire in accordance with the cur-
                            rent capacity. If the electric wire is thinner than necessity, the insulating sheath may
                            be melt and imperfect insulation may be caused. As the result, electric shock, short-
                            circuit or fire may occur.
      CAUTION            • Connect the AC power supply correctly to specified terminals. Never use unused ter-
                           minals for the outside.
                         • If the AC power supply is not correctly connected or unused terminals are used, the
                           tension control unit may be damaged.
                         • Separate the strong electric system from the weak electric system. Never perform
                           common grounding for them. If common grounding is performed, noise may be su-
                           perimposed on the weak electric system wiring and malfunction may be caused.
                         • Please do not leave the line in the controller case so much for the malfunction preven-
                           tion when wiring is too long and tne line is generated too much.
                         • Please do not birng tne AC power supply cable close to the panel side for the mal-
                           function prevention.
    Note
    This product is an electronic equipment in which a micro computer (CPU) is built in. If the CPU has become
    out of order caused by insertion of conductive foreign objects or abnormal noise into the main body, the output
    of this product is fixed. When disorder of the CPU is caused by noise, the product can be recovered to the
    normal status by turning off the power and turning it on again.
                                                         7
 3. Specifications
  Recommended sensors
       Proximity switch- - - - - - - - - - - Manufactured by SUNX
                                               Type GX-N12M proximity switch
                                               Type GX-N18M proximity switch
       Pptentiometer for touch level - Manufactured by MIDORI SOKKI
                                               Type CPP-45 potentiometer (2kW type
                                               Free rotation type with effective angle of 300 degrees
                                               (Left and right stoppers are not provided.)
       Ultrasonic sensor - - - - - - - - - - Manufactured by BAUMER ELECTRIC
                                               Type UNAM30U9103 (maximum detection distance : 100 to 600mm)
                                                                                        8
3.2 Input/output specifications
                  Items        Terminal                                      Specifications
                                  L       • 100 to 240 VAC (-15% to +10%) , 50/60 Hz • Power fuse : 250 V, 8 A built in
                    Input
                                  N       • Power consumption: 300 VA (at 24 VDC, 3A)
  Power supply
                                +12V
                                          • Power supply for proximity switch
                                 SIC
                                                                                          DC12V, 100mA or less
                                +12V
                   Out pnt                • Power supply for analog signal
                                 AIC
                                +5V
                                          • Power supply for analog signal DC5V,50mA or less
                                 AIC
                                          • Run/stop
                                RUN           ON = Run,
                                              OFF = StopDuring OFF, stop gain operation is performed.
                                          • Output remote (varid when the DIP switch is set to select the output remote )
                                REM           ON = Output generated
                                              OFF = Output stopped
                                                         (The output ON/OFF switch provided on the panel is valid.)
                                           • Reel diameter preset (parallel to reel diameter preset switch provided on
                                RSD          the panel )
                   Contact                    During ON,the initial diameter is set as the current reel diameter.
                    input                  • Acceleration gain
                                ACC
                                              The acceleration gain is valid while the input is ON.                       12V DC,
                                           • Backward rotation / foward rotation                                          7mA / terminal
  Input signals
      Vibration resistance                 • In accordance with JIS C0040. 10 to 55 Hz, 0.5mm (4. 9m / s2 maximum),
                                            2 hours in each of three axis directions .
      Impact resistance                    • In accordance with JIS C0041. 98m / s2, 3 times in each of three axis directions.
      Supply noise resistance              • By noise simulator with 1,000 Vp-p noise voltage, 1 µs noise width and 30 to 100 Hz
                                             cycle.
      Withstand voltage                    • 1,500V AC, 1 minute                Entire terminals as a whole and between the
      Insulation resistance                • 5MΩ or more by 500V DC megger ground terminal.
      Grounding                            • Class D grounding (100Ωor less)
      Operating atmosphere                 • No corrosive gas, flammable gas, conductive dust and excessive dust.
      Power switch cycles                  • Less than 20,000 times
                                                                         9
3.4 I/O operation - - - - - Example of unwinding control
                                             ( When the DIP switch is set to select the advanced function mode.)
     Operation speed
              ( m/min)
     Out remote          ON
     [REM]
                         OFF
                         ON
      Run/Stop
      [RUN]              OFF
     Acceleration gain    ON
     [ACC]               OFF
     Deceleration gain    ON
     [DCC]               OFF
                                                 Winding diameter calculation is
                                                 ececuted from ON of RUN
                                                 input to timer of stop timer.
     Control output
                                                                                             SPT
     [PP] (%)
     [TOUT] (V)
                                   A1                                      D2
                                        A2                                         D1   S2
                                                             MSL                             S1
                                                                                                   LSC
                 The key pressed at last is valid. The PALAM key                           Change the setting by turning
                 allows to select an item by repetitious operation.                             the pulser dial.
                                                                         11
4.2 Adjustment Procedure
     Set the DIP switch to select the adjustment mode.                     The setting of the DIP switch is read when the power is
     Select the simple or advanced function mode. Select                   set from OFF to ON . For approximately 2 sec after the
     use or non-use of the winding diameter input. Then, set               power is set to ON, the version of the tension control unit
     the power to ON.                                                      is displayed on the display in upper right of the panel.
Select the menu No. to be set Select a desired No , using the menu selector keys .
     0 :Maximum winding                 F :Minimum diameter setting         0 :Maximum diameter setting        F :Minimum diameter setting
        diameter setting
        Tension setting monitor         Minimum diameter teaching                                             Minimum diameter teaching
                                        0 :Maximum diameter setting                                            0 :Maximum diameter setting
                                        Maximum diameter teaching                                             Maximum diameter teaching
                                          Tension setting monitor
     Setting is completed.
     When setting/adjustment is finished or many menu items are to be set, change the menu No, and perform the setting
     procedure again.
        Tension setting monitor             Tension setting monitor            Tension setting monitor            Tension setting monitor
                                                                            1 :Taper setting                   1 :Taper setting
        Material thickness setting                                          2 :Stop timer setting              2 :Stop timer setting
        Initial diameter setting                                            3 :Stop gain setting               3 :Stop gain setting
                                                                            4 :Stop bias setting               4 :Stop bias setting
                                                                            5 :Deceleration gain setting       5 :Deceleration gain setting
                                                                            6 :Acceleration gain setting       6 :Acceleration gain setting
            For the teaching procedure when the winding                        Material thickness setting
            diameter input is used , refer to p . 14.                          Initial diameter setting
                                                                      12
                                                                    Operating / Setting Procedure
4.3 Details of set items
                          • Material thickness setting
                           When the material thickness key is pressed, its set value is displayed.
                           The unit of the material thickness setting is changed over between 1 Éþm and 0.1 Éþm in
                           accordance with the setting of the DIP switch. The decimal point is displayed on the 7-seg-
  When the reel            ment display for the material thickness setting. When the material thickness setting is
   diameter input is       changed while the reel diameter is being calculated, the reel diameter calculation is
                           changed in proportion to the material thickness.
  used, refer to p. 14.
                           By this function, in the material thickness setting, the calculated reel diameter and the actual
                           reel diameter can be aligned with each other. When many materials are wound in one layer
                           as in a wire material, the setting shall be in accordance with the following formula.
                                   Material thickness set value = (Thickness of one layer/Number of turns of one layer)
                          Every time the PALAM key is pressed, the items are displayed one by one in turn as shown
     PALAM.               below.
                          Display symbols are represented in simplified alphabets as shown below.
                                                           13
                                                                                      Details of set item
                        8. Little excitation current setting - - LSC (Low Supply Current)
                         Is valid in the advanced function mode exclusively and set so that the output does not become
                         0 and the little excitation current is applied in a powder clutch/brake even if the control output
                         is set to OFF by the ON/OFF switch or the output remote.
                         Adjust the little excitation current so that the reel shaft is rotated even when the material is re-
                         moved.
                                                          14
  5. Inspection, Trial Run and Adjustment
5.1 Initial Inspection - - - - Power = OFF
   1. Confirming the selection
     • Before starting operation, make sure that a tension control unit, an actuator and sensors are correctly
       selected. The output current of the type LD-30FTA tension control unit is 24 VDC, 3 A or less. If clutch-
       es/brakes to be used exceed this output current, use power amplifies together.
     • The capacity of an actuator is selected based on the production line speed multiplied by the operation
       tension. A tension beyond this capacity can be set in a tension control unit. In such a case, however,
       the actuator may be burned out.
       Make sure that the operator understands the available upper limit tension determined based on the
       heat capacity of the actuator.
     • If the tension is too Low, operation becomes unstable when the machine is started up or stopped. De-
       termine an appropriate lower limit, and let the operator understand it.
   2. Operation sequence
     • Check the operation sequence and the emergency stop sequence.
       Especially, when a servo motor is used as an actuator, the motor may become out of order if the ma-
       terial is cut. When the material is cut, set the speed limit input for the motor to 0.
                                                       15
5.5 Abnormality Inspection
  Check abnormality of the tension control unit during trial run and adjustment or during actual operation in
  accordance with the table shown below.
            Item               Phenomenon                                    Countermeasures
                                                       1. Check whether the supply voltage between the L and N terminals
                          The power indicator lamp        is 100 to 240 VAC (-15 to +10%), 50/60 Hz. If this voltage is not
                                                          given, correct the wiring.
                          is not lit even if the power
                                                       2. A fuse may be melted down caused by insertion of foreign
                          switch is set to ON.            objects or abnormal load.Even if a melted fuse is replaced, the
                                                          tension control unit may not be recovered to the normal status.
                                                    1. When control output is not generated even if the output ON/OFF
       Short-circuit of                                key provided on the panel is manipulated, check whether the
       load related to                                 clutch/brake model is appropriate (The rated current should be 3
        power supply                                   A or less.), whether the clutch/brake is correctly connected and
                          The control output is not    whether short circuit has not occurred.
                          generated even if the     2. When short-circuit has occurred in the load, remove the cause,
                          pulser dial is turned in     turn off the power for several minutes, and turn on the power
                          the manual mode.             again. Then, the tension control unit will be recovered to the
                                                       normal status.
                                                    3. When the TOUT/AOC terminal is used, make sure that the load
                                                       resistance is 1kΩ or more.
                          Sufficient control output
                                                        If the maximum reel diameter parameter is not set appropriately,
                          is not generated in the
                                                        sufficient output cannot be obtained.
                          automatic mode.
                                                      1. When the diameter analog input is not used
                                                         Observe the reel shaft pulse monitor, and check whether the reel
                                                         shaft pulse is entered. If the pulse is not generated, check
                                                         whether an appropriate proximity switch is used, whether the
                                                         proximity switch is correctly wired and whether the ON duration
                                                         and the OFF duration are appropriate.Make sure that the voltage
                                                         of the reel shaft pulse between the input terminals SPA and SIC
     Abnormal opera-                                     is 1 V or less while the input is set to ON and 9 V or more while
     tion in automatic Appropriate control out-          the input is set to OFF.
           mode        put is not generated in
                          accordance with change 2. When the winding diameter input is used
                          in the winding diameter.  Check whether the minimum diameter and the maximum diame-
                                                    ter are set appropriately and whether teaching has been per-
                                                    formed. Check whether change in the voltage between the input
                                                    terminals AID and AIC is appropriate against change from the
                                                    minimum diameter to the maximum diameter.Inside the tension
                                                    control unit, an analog value of 0 to 10 V is handled as a digital
                                                    value of 0 to 4095 steps. For example, when the variation of the
                                                    input voltage against change from the minimum diameter to the
                                                    maximum diameter is 1 V, the resolution becomes 409 steps.
       DANGER             • Provide the emergency stop circuit for the machine outside the tension control
                            unit.
                            If it is built in the tension control unit, the machine may become out of order and
                            accidents may be caused when malfunction occurs in the tension control unit.
       CAUTION            • Never manipulate switches and keys with wet hand. If you touch them with wet
                            hand, you may get electric shock.
                          • Never supply the power to or operate the tension control unit while the main body
                            door, the terminal cover, etc. are open. If the high voltage portion is exposed, you
                            may get electric shock.
                                                            16
  6. Setting Examples
                                                                                         Proximity
                                                                                          switch
                                                                                                                                                Other applications
                                                                                                                                                 • Hot stamping
                                                                                                                                                 • Screen printer
                                                        Powder clutch
                                                         ZKB-2.5BN
                                                                                             Geared motor
                                                                                            GM-H0.2KW1/60       Tension control unit
                                                                                                                     LD-30FTA
  Setting of the DIP switch (This step is required only at the time of initial startup,
  and is not required during normal operation.)
                 1        2        3       4        5         6          7          8                          1         2       3        4        5          6         7           8
       ON    Unwinding   ×1      Unused Unused Always      Normal       Easy     Operation           ON     Unwinding    ×1    Unused Unused Always       Normal       Easy     Operation
                                                           Memory                                                                                         Memory
       DIP Controlled Thickness Winding Output     No                  Function Operation             DIP Controlled Thickness Winding Output     No                Function Operation
                                diameter                    initiali                                                           diameter                    initiali
      switch shaft       unit            remote function                mode     mode                switch shaft        unit
                                                                                                                                  input remote function              mode     mode
                                  input                     zation                                                                                        zation
       OFF    Winding    ×0.1    Used    Used              Initialization Advanced Tunning           OFF    Winding     ×0.1    Used    Used              Initialization Advanced
                                                                                                                                                                          function Tunning
                                                                           function
     (Initial value setting )                                                                                           Set the eighth (operation mode) DIP switches
                                                                                                                        to "RUN" when you drive.
  Setting procedure (This step is required only when the material is changed.)                                                                 • Material
  • Press the material thickness set key, and set the material thickness to 200µm                                                                thickness display
    by turning the pulser dial.
  • Press the initial diameter set key, and set the reel diameter to φ92 by turning
    the pulser dial.                                                                                                                                                            φ
  • Press the reel diameter reset key.
                                                                                                                                               • Winding
                                                                                                                                                 diameter display
                                                                                                                                                                                 φ
  Trial run (This step is required only at the initial startup, and is not required during easy operation.)
  • Press the manual control mode key, and set the output ON/OFF switch to ON.
  • Check diversified functions such as the motor and the sequence.
  Automatic operation
  • Press the automatic control mode key (only when the manual mode is selected).
  • Adjust the tension to an appropriate value by turning the tension set trimmer.
                                                                                             17
6.2 Application example : Ultrasonic sensor
  Electric wire not processed by the sheathing unit yet is unwound while such a tension as not to slack the
  electric wire is applied.
  Because the open loop control is performed, hunting does not occur in the traverse direction.
  Because an ultrasonic sensor detects the reel diameter, the initial diameter and the wire diameter are not
  required to be set.
                                                                                                            Other applications
                                                                                                             Sheet cutter which is often started up and stopped
            Tension control unit
                                       + Analog input board
                LD-30FTA                       LD-30FTA-1AD
     Use example of an ultrasonic sensor (simple mode) (equivalent for a touch lever)
     When the reel diameter is changed from 300 to 80 in the example above
  Setting of the DIP switch (This step is required only at the time of initial startup, and
  is not required during normal operation.)
                1         2       3       4        5          6              7         8                         1            2     3        4        5          6        7         8
      ON     Unwinding   ×1     Unused Unused Always      Normal            Easy    Operation          ON     Unwinding    ×1     Unused Unused Always     Normal        Easy    Operation
                                                          Memory                                                                                              Memory
      DIP Controlled Thickness Winding Output     No                       Function Operation          DIP Controlled Thickness Winding Output     No                   Function Operation
                               diameter                    initiali                                                             diameter                       initiali
     switch shaft       unit            remote function                     mode     mode             switch shaft        unit           remote function                 mode     mode
                                 input                     zation                                                                  input                      zation
                                                                           Advanced
      OFF    Winding     ×0.1   Used    Used              Initialization    function Tunning          OFF     Winding     ×0.1     Used     Used           Initialization Advanced
                                                                                                                                                                           function Tunning
    (Initial value setting )                                                                                              Set the eighth (operation mode) DIP switches
                                                                                                                          to "RUN" when you drive.
  Teaching procedure
  (This step is required only at the time of initial                                    • Minimum
  startup, and is not required during normal op-                                          diameter display
  eration.)
  • Set the minimum diameter (φ80) by turning                                                                             µm
    the pulser dial. Set the reel bobbin of the
    minimum diameter. Press the reel diameter
    reset key.                                                                                                            φ
                                                                                                                                                                     Winding bobbin
  Manual operation (This step is required only at the initial startup, and is not required during normal op-
  eration.)
  • Press the manual control mode key, and set the output ON/OFF switch to ON.
  • Check diversified functions such as the motor and the sequence.
  Automatic operation
  • Press the automatic control mode key (only when the manual mode is selected).
  • Adjust the tension to an appropriate value by turning the tension set trimmer.
                                                                                                18
 7. Supplements on Operating Procedure
7.1 Manual torque adjustment and the role of the pulser dial
  Power switch 1 is set to ON. → Power indicator lamp is lit. Manual control mode key 17 is pressed. → Manual
  operation mode indicator lamp is lit.
  Output ON/OFF key 13 is pressed. → Output indicator lamp is lit. Display selector key 8 is pressed. → Unit
  indicator lamp " % " is lit.
                                             When the manual control mode is selected, the manual control
     100%                                    output value just before becomes valid and is displayed on the
                                             monitor display 11.
             Counterclockwise                When the pulser dial 16 is turned clockwise or counterclockwise
                 rotation                    in this status, the control output is increased or decreased. After
     Control                                 the control mode is changed over from manual to automatic, the
     output                                  output is gradually shifted to the output in accordance with the
                                  Clockwise
                                    rotation winding diameter.
                        Current value        All other diversified set data is saved in the memory inside the
                                             tension control unit.
                                             When this data is read and displayed, then adjusted (increased
                         Pulser dial         or decreased) using the pulser dial, the adjusted result is saved
                                             as the latest data.
7.2 Relationship between the tension setting and the maximum tension
  Power switch 1 is set to ON. → Power indicator lamp is lit. Automatic control mode key 14 is pressed. → Auto-
  matic operation mode indicator lamp is lit.
  Output ON/OFF key 13 is pressed. → Output indicator lamp is lit.( PALAM key 8 is pressed. → Set value
  is displayed on display 4 in lower left.)
                                             The set tension is changed within the range of 0 to 100% in accor-
    100%                                     dance with the setting of the scales 0 to 10 of the tension set trim-
                                             mer 15.
               Operation tension F%          When the scale of the tension set trimmer 15 is required to be
                                             read correctly, press the PALAM key 8. Then, the set value is dis-
                                             played as 0 to 100% on the display in lower left on the panel.
                                             The 100% tension indicates the rated torque of the actuator divid-
                                             ed by the maximum radius of the reel bobbin.
                                             However, if a speed reducer is provided between the reel bobbin
                                             and the actuator, the 100% tension shall be the rated torque con-
                                             verted for the reel shaft.
           0     Tension set scale     10    The maximum radius shall be the maximum reel diameter set by
                                             the parameter divided by 2.
7.3 Role of the keyin inhibit key
  Tunning mode
     • While the DIP switch is set to select the tunning mode, all the parameters can be adjusted without re-
       gard to the setting status of the keyin inhibit function. However, parameters to which the keyin inhibit
       function is set in the adjustment mode cannot be displayed or set when the DIP switch is switched over
       to the operation mode.
     • For example, if the keyin inhibit function is set to all the parameters in the tunning mode, the material
       thickness setting, the reel diameter setting and the tension setting exclusively are valid in the operation
       mode. (The system parameters can be set in the tunning mode exclusively without regard to the set-
       ting status of the keyin inhibit function.)
     • Parameters to which the keyin inhibit function can be set.
       Taper ratio, stop timer, stop gain, stop bias, deceleration gain and acceleration gain.
  Operation mode
     • When the keyin inhibit function is set in the operation mode, items for which change of the setting was valid
       become invalid with regard to change of the setting, and do not accept manipulation of the pulser dial. Such
       items do not accept the menu selection key either in the easy mode. (Manual control is valid.)
     • The reel diameter reset key is valid without regard to the setting status of the keyin inhibit function. It
       is actuated when it is pressed and held for 1 sec or more.
       In the advanced function mode, however, menu selection is not accepted while the machine is operating.
7.4 How to use the menu selection function
  When eight types of menus are preliminarily registered by combining diversified parameters, the operator
  can perform optimal operation using diversified operation constants only by selecting a registered menu.
    The following parameters can be registered for these menus.
          In the easy mode               : Material thickness and initial diameter
          In the advanced function mode  : Material thickness, initial diameter, taper ratio, stop timer, stop gain,
                                           stop bias, deceleration gain and acceleration gain
    The parameters marked with underline are changed by the menu selection even if displayed at the op-
    eration mode.
  Menu can be changed at either sasy mode or advanced function mode during control output is off.
                                                         19
7.5 Flickering of indicator lamps and its meaning
  • When the material thickness set key is pressed and the material thickness can be set using the pulser dial,
    the unit indicator lamp µm flickers. It is lit when the initial diameter set key is pressed and the initial di-
    ameter unit lamp φflickers when the PALAM key is pressed.
  • When the initial diameter set key is pressed and the initial diameter can be set using the pulser dial, the
    unit indicator lamp É” flickers. It is lit when the material thickness set key is pressed and the material thick-
    ness uni lamp µm flickers when the PALAM key is pressed.
  • When the material thickness set key, the initial diameter set key or the PALAM key is pressed in the manual
    control mode, the manual operation mode indicator lamp flickers. At this time, the manual output is fixed
    to a value just before, and parameters can be set based on each set key using the pulse dial. When the
    manual control key is pressed again, the manual operation mode indicator lamp is lit and the manual out-
    put can be adjusted using the pulser dial.
  • In the automatic control mode, the automatic operation indicator lamp is lit.
  In the advanced function mode, however, the automatic operation indicator lamp is lit while the RUN input
    is ON or flickers while the RUN input is OFF.
    While the stop timer is operating, the automatic operation indicator lamp is temporarily extinguished.
  • Immediately after the power is turned on, the version flickers.
  • When the calculated reel diameter is 2,000 mm or more, φ2000 flickers as the reel diameter. When the
    calculated reel diameter is less than 0 mm, "-0.0.0." flickers as the reel diameter.
  • While the control output is OFF, " OFF " flickers. While the weak excitation output is generated, a value
    flickers on the monitor display.
                                                                     20
7.8 Guideline of allowable minimum tension
  The allowable minimum tension with which opera-                                                                                             α: Acceleration /deceleration
  tion is possible in the torque tension control unit                                                           Minimum operation tension
                                                                                                                                                 ( m/ min/s)
                                                                                                     150                                                            α=10
  If the machine is operated with a tension less than
                                                                                                     100
  the minimum tension, stable operation cannot be
  assured when the machine is accelerated or de-                                                      50
  celerated.
                                                                                                      0
                                                                                                      0.0                 0.5           1.0                      1.5
                                                                                                                Fully wound winding bobbin weight (×10 3kg)
7.9 Major differences from the type LD-FB type tension control unit
  The table below shows major differences between the conventional type LD-FB tension control unit and the
  type LD-30FTA tension control unit. The type LD-30FTA can be used as a succeeding model of the type
  LD-FB tension control unit.
                             Type LD-FB tension control unit                                                   Type LD-30FTA tension control unit
      Power supply      100/110 VAC dedicated, uninsulated output                                         100 to 240 VAC system, insulated output
      Output            DC24V 3.6A                                                                        DC24V 3.0A
      capacity
      Winding           Integrated thickness method based on reel                                         Integrated thickness method based on reel shaft
      diameter          shaft pulse (1rotation = 1 pulse) Initial diameter                                pulse (1rotation = 1, 2, 4 or 8 pulses) When an
      calculation       and material thickness are set by digital                                         optional card is mounted, reel diameter can be
      method            switches on panel.                                                                entered.
      Inertia
      compensation      Acceleration gain and deceleration gain are set Acceleration gain, deceleration gain, stop gain, stop
      control           by externally installed trimmer.                bias and stop timer are set by parameters.
                                                                                                          Little excitation output, mechanical loss correction
      Other functions                                                                                     and taper ratio are set. Material thickness unit is
                                                                                                          changed over.
7.10 Output remote input and the output ON/OFF key provided on the panel
  When this input is turned on/off, the remote function of control output is turned on/off.
  This input has the priority over the OUTPUT ON/OFF switch provided on the panel.
                               OUTPUT
                             ON/OFF Switch
Control output
                             (Note) Use the Output ON/OFF key 13 or [REM] input without using
                                      the Power switch 1 when the output is turned on and off.
                                         • Allowable power switch life cycles : 20,000 times
                                                                21
7.11 Relationship between the acceleration/deceleration gain and the
     winding / unwinding/backward rotation input
  • The acceleration gain and the deceleration gain can be set respectively to 5 to 400% of the current output.
    To activate such gains, the ACC terminal (for the acceleration gain) and the DCC terminal (for the decel-
    eration gain) are set to ON.
  • In unwinding control, it is ideal to decrease the control output when the machine is started up and increase
     the control output when the machine is stopped.
     In winding control, it is normal to increase the control output when the machine is started up and decrease
     the control output when the machine is stopped.
  • Use any combination in accordance with your application without sticking to terms "acceleration" and "de-
    celeration".
    When the operation direction is reversed and the backward rotation/forward rotation is given, arithmetic
    operation for pulses is automatically changed over between addition and subtraction.
    However, as to the acceleration gain and the deceleration gain, change them over using an external se-
    quence and set an appropriate control input ACC (or DCC) side to ON.
Potentiometer
           Maximum                                                             Backlash
        winding diameter
                                         Reel bobbin                                             Reel bobbin
           Minimum
        winding diameter
         Install the ultrasonic sensor to that the dis-        Install the touch lever so that the operation an-
         tance detected by the ultrasonic sensor is in         gle of the potentiometer becomes as large as
         accordance with the sensor model, and be-             possible.
         comes maximum when the reel diameter is               If the touch lever is vibrated caused by eccen-
         minimum.                                              tricity of the reel bobbin, provide a backlash
                                                               between the touch lever and the potentiome-
                                                               ter drive shaft so that minute motions of the
                                                               potentiometer are not repeated.
                                                          22
7.13 Non-linear compensation number table
                                          Powder clutch                                                        Powder brake
                                     Type name                No.                                         Type name             No.
                                            ZKG-5AN           101                                                ZKG-5YN        51
                                            ZKG-10AN          102                                                ZKG-10YN       52
                                            ZKG-20AN          103                                                ZKG-20YN       53
                                            ZKG-50AN          104                                  Self-cooling ZKG-50YN        54
                              Self-cooling
                                            ZKG-100AN         105                                                ZKB-0.06YN      1
                                            ZKB-0.06AN         81                                                ZKB-0.3YN       2
                                            ZKB-0.3AN          82                                                ZKB-0.6YN       3
                                            ZKB-0.6AN          83                                                ZKB-1.2XN       4
                                            ZA-10A1/AN         95                                                ZA-40Y         17
                                            ZA-20A1            96                                                ZKA-2W         61
                                            ZKA-1A1           141                                                ZKA-6W         62
                                            ZKA-2A1           142                                 Water-cooling ZKA-10W         63
                                            ZKA-6A2           143                                                ZKA-20W        64
                                            ZKA-10A2          144                                                ZKA-45W        65
                              Self-cooling
                                            ZKA-20A3          145
                                            ZKA-45AT      ∗   146
                                            ZKA-65AT     ∗    147
                                            ZKA-100AT    ∗    148
 As the rated current of the models indicated by ∗ mark will exceed the rated output current (3A) of LD-
 30FTA, please connect the power amplifier satisfying the rated current of each model to the TOUT-AOC
 terminal, then control through this power amplifier.
                                                                    23
     JZ990D41401D
24