ba HUXLEY Professional Manufacturer of Sterilizers with 30 years Experience & GMP Certified. HL-380P Automatic Pulse-Vacuum Steam Sterilizer HL-380P is an efficient and reliable automatic steam sterilizer. Specially ‘designed for large capacity and highest flexibility in processing requirement. It-can be used in a hospital for efficent, high-volume processing of heat and moisture stabile materials, such as fabrics, wrapped hard goods, liquid or glassware etc Features 1, Control system: automatic control system provides strict control of sterilize temperature, time, pressure etc. to assure Consistent, accurate periormance, 2, Sterilizer cycles: there are 3 pre-programmed cycle selections that can process various load types in ths sterilizer. For easy sterilizer operation: 1 Unwrapped cycle; 2 Wrapped cycle; 3 Liquid cycle. 3, Automatic operation: cycle progresses automatically through pulses acuum, sterilizing, exhaust, vacuum drying and venting phases. biog 4. Temperature controller: sterilize temperature can be set from 121°C to 132°C on digital temperature controller. When setting temperature is achieved the process of sterilizing cycle will automatic operating. 5. Timer: sterilize time and dry time can be set from 0 39minutes on digital sterilizing timer and drying timer. The timer starts only after the pre-set temperature is reached, ensuring complete strlization. 6, Status display: illuminated pilot lamps display status and a buzzer announces the completion and cuts off the heating power source. 7. Pressure gauge: the large diameter of chamber pressure gauge and jacket pressure gauge make ideal require reading and Indicate high precision and Consistent results. 18, Heating system: integral steam generator is equipped with a high efficient meson Heatran automatic es water device to supply seam to sterilizer. ‘9, Vacuum system: contralled and monitored pulses vacuum and drying phase effectively condition loads of various size and density...reducing. total sterilization time. System includes a condenser and water ejector. 10, Steam rap: discharges condensate rom chamber to obtain fective Saturated steam, 11. Airfilter: an effective HEPA air filter is used to prevent contaminated air from entering into the chamber. 12, Chamber door: chamber door is manually operated and actuated by rotating a door handle. 13, Gasket: the silicone-rubber sealing gasket is applied to an even pressure door seal 14, Chamber shell: cylindrical chamber provides a large capacity to saisfy a wide range of sterile processing needs. Chamber is made of high quality SUS 3161 stainless steel with polished surface for long lasting service and easy cleaning. A double layer Construction is thermally insulated with foil backed fiberglass insulation. Safety devices 1. Safty door switch: cycle does not start unless chamber is locked also door-unlocked signal is displayed on the control panel. 2. Door interlock: door safety locking device keep door fram being opened while chamber is pressurized during cycle. 3. Safety valve: releasing steam in case of excessive chamber pressure. 4, Overheating protection device: high temperature deviation in chamber actuates protective device culs off the heating source immediately 5. Low water protection device: low water level in steam generator will actuate audible alarm and protective device cut off the heating 6. Circuit protection device: circuit breaker and fuse protects control units when short circuit or overload occurs. 7. Emergency exhaust: manual exhaust to vent the chamber and remove the load in the event of a power outage. Norms and standards 1. The product has been tested with the standards: IEC 61010-1:2001, IEC 61010-2-40:2005 is considered to satisfy with the MOD 93/42/EEC, 2. Ts product has been tested confirmed to comply with the requirements of the EMC standard. 3. Manufacturer corresponds with quality system certified to GMP Taiwan. Accessories 1. Bottom shelfx<1 2. Operation manualy<1 ‘Options [Thermal printer - provides an easy to read printed record ofall pertinent cycle data. [Vacuum pump — replace vacuum system's condenser and water ejector to vacuum pump to reduce water consumption. Double door Notes Sterlizers warated to one year, exc consumable heater gasket, HEPA air filter etc) Speciftions ee 1 exon ‘Chamber Size | Volume | Door [Temperature] MAW.P = ‘Working | & Drying ew | Chamber | Chamber | oe ees “tier | Steam [een] Per Door tom | [ovemten| conser [oem |" Henpeate] ine | Seam [eo veal | (Co) | crm) [Sees tea ashe ‘@as0xpes0 | 151 LED Digtal 2 |220/380v| stainless | stainless ans : ia-sooe] 2590-01009 | 336 Hewoemnve| 25 | sme | a | og | 22 | 25 Japuemi| ste | set @ro0xD1200 | 462 [EPO] Contoter pe sojéoe | suszist] susio% Hung Lin Medical Instruments Co., Ltd. Address: No.15, Laneé1, Kuang Fu Rd., Sec.1, San Chung, Taipei, Taiwan, Tel: 886-2-83356266 Fax: 886-2-22782878 HUXLEY E-mail: huxiey@ms22.hinet.net

You might also like