This international standard specifies the dimensions of refractory bricks for use in the domes of electric arc furnace roofs. Table 1 provides the dimensions of dome bricks for electric arc furnace roofs with roof thicknesses of 230 mm or 250 mm and nominal spherical radii of 2.7 m, 4.5 m, or 6.3 m. The bricks are designated by a reference number indicating the roof thickness, spherical radius, and side arch taper.

Uploaded by

mystar_bkc
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
90 views9 pages

ISO 05019-4-1988 Scan

This international standard specifies the dimensions of refractory bricks for use in the domes of electric arc furnace roofs. Table 1 provides the dimensions of dome bricks for electric arc furnace roofs with roof thicknesses of 230 mm or 250 mm and nominal spherical radii of 2.7 m, 4.5 m, or 6.3 m. The bricks are designated by a reference number indicating the roof thickness, spherical radius, and side arch taper.

Uploaded by

mystar_bkc
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

I S0

I N TE RN ATI ON AL S TAN D ARD 501 9- 4


S e co n d e d i ti o n

1 988- 1 1 - 01

I N TE RN ATI ON AL ORG AN I ZATI ON F O R S TAN D ARD I ZATI ON

ORG AN I S ATI ON I N TE RN ATI ON AL E DE N ORM AL I S ATI ON

M E XAYH AP O AH AR OP ~ AH M 3 A~ kl R n0 CTAH AAP TM 3 AL &l ! 4

Refracto ry bri cks - Di m e n si o n s -

Part 4:

Do me bri cks for el ectri c arc fu rn ace ro o fs

Bri q u e s rh fractai res - Di m e n si o n s -

Parti e 4: Bri q u e s de vo fi te po u r fo u rs kl ectri q u e s

Re fe r e n ce n u m b e r

I S0 5 0 1 9 - 4: 1 9 8 8 ( E)
IS0 501 9-4 : 1 999 (El

Foreword
IS0 (the International Organization for Standardization) is a worldwide federation of
national standards bodies (IS0 member bodies). The work of preparing International
Standards is normally carried out through IS0 technical committees. Each member
body interested in a subject for which a technical committee has been established has
the right to be represented on that committee. International organizations, govern-
mental and non-governmental, in liaison with ISO, also take part in the work. IS0
collaborates closely with the International Electrotechnical Commission (IEC) on all
matters of electrotechnical standardization.
Draft International Standards adopted by the technical committees are circulated to
the member bodies for approval before their acceptance as International Standards by
the IS0 Council. They are approved in accordance with IS0 procedures requiring at
least 75 % approval by the member bodies voting.
International Standard IS0 501 9-4 was prepared by Technical Committee ISO/TC 33,
Refractories.
This second edition cancels and replaces the first edition (IS0 501 9-4 : 1 9941 , of which
it constitutes a technical revision.
IS0 501 9 consists of the following parts, under the general title Refractory bricks -
Dimensions:
Part 7: Rectangular bricks
Part 2: Arch bricks
Part 3: Rectangular checker bricks for regenerative furnaces
Part 4: Dome bricks for electric arc furnace roofs
Part 5: Skewbacks
Part 6: Basic bricks for oxygen steel-making converters

0 International Organization for Standardization, 1 999 l


Printed in Switzerland
I NTERNATI ONAL STANDARD I S0 501 9- 4 : 1 999 (El

Refractory bri cks - Di men si on s -

Part 4 :

Dome bri cks for el ectri c arc fu rnace roofs

1 Scope an d fi el d of appl i cati on 3. 2 Desi g nati ons for tabl e 1

Th i s part of I S0 501 9 speci fi es th e di men si on s of refractory a) Th e fi rst l etter ( H, J or K) i n di cates th e bri ck l en gth
bri cks for u se i n th e d omes of el ectri c arc fu rn ace roofs. (roof th i ckn ess) ( 230 mm; 250 mm or 300 mm) ;

I n th e an n ex, th e di men si on s of speci al bri cks al so u sed for th e b) Th e secon d l etter ( W, X, Y or Z) i n di cates th e sph eri cal
con stru cti on of th ese fu rn aces are g i ven for i n formati on on l y. radi u s (2, 7 m; 4, 5 m; 6, 3 m or 91 m) ;

c) Th e di gi t i n th e thi rd pl ace (I , 2, 3 or 4) i n di cates th e


2 Di men si on s si de arch taper ( 2 mm; 3 mm; 6 mm or 1 3 mm) .

Th e di men si on s of refractory bri cks for u se i n th e d omes of

el ectri c arc fu rn ace roofs shal l be as sh own i n tabl es 1 to 3.


3. 3 Desi g nati ons for tabl es 2 and 3

N OTE - Normal l y ei ther bri cks excl u si vel y from tabl e 1 or combi -
a) Sph eri cal d ome bri cks (tabl e 2) are desi g n ated by th e
nati ons from tabl es 2 and 3 are used.
l etters “KR” an d rectan gu l ar d ome bri cks (tabl e 3) by th e

l etter “I V’ .

3 Bri ck desi gnati ons


b) Th e fi rst di gi t of th e desi gn ati on n u mber sh ows th e fi rst

di gi t of th e sph eri cal radi u s, i n mi l l i metres.

3. 1 General
c) Th e secon d di gi t of th e desi gn ati on n u mber sh ows th e

Th e bri cks of th e speci fi ed di men si on s shal l be desi g n ated by roof th i ckn ess, th e rel ati on sh i p between th i s di men si on an d

th e referen ce n u mbers sh own i n tabl es 1 to 3. th e di gi t bei n g as sh own i n tabl e 4.

1
IS0 501 9-4 : 1 999 (El

Table 1 - Dimensions of dome bricks for electric arc furnace roofs

c
r-- ?
L-.-J

I-1EPlan

Roof Nominal
thickness Brick dimensions
spherical mm Reference
H radius
A B C D E F No.
mm m
114 1 08.5 76 72,5 73 69.5 HX2
4,5 114 1 08,5 76 72,5 70 67 HX3
114 1 08,5 76 72.5 63 60 HX4
230
114 1 05 76 70 73 67 HW2
2‘7 114 1 05 76 70 70 64.5 HW3
114 1 05 76 70 63 58 HW4
114 1 1 0,5 76 73,5 74 71 ,5 JZI
&I 114 1 1 0,5 76 73,5 73 70,5 JZ2
114 1 1 0,5 76 73‘5 70 67.5 JZ3
114 1 1 0,5 76 73,5 63 61 JZ4
250
114 1 09,5 76 73 74 71 JYl
63 114 1 09,5 76 73 73 70 JY2
114 1 09,5 76 73 70 67 JY3
114 1 09,5 76 73 63 60,5 JY4
114 110 76 73,5 74 71 ,5 KZl
8.1 114 110 76 73,5 73 70,5 KZ2
114 110 76 73,5 70 67,5 KZ3
114 110 76 73,5 63 61 KZ4
300
114 1 09 76 72,5 74 70,5 KY1
63 114 1 09 76 72,5 73 69,5 KY2
114 1 09 76 72,5 70 67 KY3
114 1 09 76 72,5 63 60 KY4

2
I S0 501 9- 4 : 1 988 (E)

Tabl e 2- Di men si on s of sph eri cal d ome bri cks for el ectri c arc fu rn ace roofs

-I
r--

1
L--J

Pl an

Roof Nomi n al
Bri ck di men si on s
th i ckn ess sph eri cal
mm Reference
H radi u s

A B D E F No.
c
mm m

200 zo 1 32 1 20 93 85 71 65 KR20

3, O 1 28 1 20 89 83. 5 71 , 5 67 KR30

3, O 1 30 1 20 90, 5 83, 5 72, 5 67 KR32

4, O 1 28 1 20 87 82 72 68 KR42

250 5, O 1 26 1 20 86 82 72 68 KR52

6. 0 1 25 1 20 85. 5 82 71 68 KR62

7, O 1 24, 5 1 20 85 82 71 68 KR72

4, O 1 29 1 20 1 it :; 5; : KR43

5, O 1 27 1 20 KR53

300 6’3 1 26 1 20 86 82 71 , 5 68 KR63

7, O 1 25 1 20 85, 5 82 71 68 KR73

30 1 24 1 20 85 82 70, 5 68 KR93

3
I S0 501 9- 4 : 1 999 (El

Tabl e 3 - Di men si on s of rectangul ar dome bri cks for el ectri c arc fu rnace roofs

Roof Nomi n al
Bri ck di men si on s
th i ckn ess spheri cal
mm Reference
H radi us
No
A B c D
mm m

200 a0 1 32 1 20 82, 5 75 R20

3, O 1 28 1 20 80 75 R30

3, O 1 30 1 20 81 75 R32

4, O 1 28 1 20 80 75 R42

250 5, O 1 26 1 20 79 75 R52

60 1 25 1 20 78. 5 75 R62

7, O 1 24, 5 1 20 78 75 R72

4, O 1 29 1 20 81 75 R43

5, O 1 27 1 20 80 75 R53

300 60 1 26 1 20 79 75 R63

7, O 1 25 1 20 78 75 R73

98 1 24 1 20 77, 5 75 R93

Tabl e 4 - Combi n ati on of roof th i ckn ess and sph eri cal radi u s

Roof Possi bl e spheri cal radi i


th i ckn ess Desi gnati on ,

mm mm

200 0 2000 3000

250 2 3000 4000 5000 6000 7000

300 3 4000 5 000 6000 7 000 9000

4
I S0 501 9- 4 : 1 999 ( E)

An n e x

El e ctro d e an d fu me take - o ff b r i cks

( Th i s an n e x d oes n ot fo r m an i n teg ral part of th e stan d ard . )

Tabl e 5 - Di m e n s i o n s of e l ectro d e an d fu me take- o ff b r i cks

Di m e n s i o n s in m i l l i m e tr e s

a P n x7 0 0

- -

- -

2 C

i 5 - z:
b h

L- l

' - RI O

Di m e n s i o n s I n n er

Re fe re n ce
mm d i ame te r

No.

a b h n 0
‘I I -J
1 2

DI N 61 29, 5 1 1 5 95 2 60 60 60 1 40

D2 N 74, s 40 1 1 5 95 2 60 60 60 2 80

D3 N 1 1 8, 5 45 1 40 1 30 320 55 55 1 80

D4 N 90 53 1 40 1 30 320 55 55 42 0

D5 N 1 1 1 64 1 50 1 40 3 75 50 45 42 0

D6 N 94 63 1 50 1 40 3 75 50 45 62 0

D7 N 1 08 67, 5 1 80 1 70 450 50 50 62 0

D6 N 92 65, 5 1 60 1 70 460 50 50 900

92 72 1 80 1 70 450 50 50 1 300

5
I S0 661 9- 4 : 1 966 (E)

U DC 666. 76431 : 621 366. 2

Descri ptors : el ectri c arc fu rnaces, refractory materi al s, bri cks, di men si ons, desi gnati on.

Pri ce based on 5 pages